02-28-2015, 01:50 AM
hi friends i have a vas5054. i was using vas-pc v19. now i have a problem.
my problem is «EDIC-API delivers a system error» but i tried other vas5054 and it is working well. was my vas5054 interface broke? can you help me?
Thanks given by:
satli
Location Offline
Junior Member
Reputation:
0
Thanks Given: 42
Thanks Received: 5 (3 Posts)
Posts:
11
Threads:
2
Joined: Dec 2017
2
01-03-2021, 10:56 AM
I have the same problem, do you have a solution?
Thanks given by:
kursuni
Location Offline
Junior Member
Reputation:
1
Thanks Given: 27
Thanks Received: 9 (7 Posts)
Posts:
91
Threads:
48
Joined: Oct 2011
3
03-19-2021, 06:55 PM
(01-03-2021, 10:56 AM)satli Wrote: I have the same problem, do you have a solution?
was this problem solved. have same error on windows 7 32bit
Thanks given by:
3. After installation is complete, the VAS 5054A must be detected by the Bluetooth software.
The software offers a function for listing all the Bluetooth devices in range. Make sure your
VAS 5054A is connected to the power supply and is within range. The VAS 5054A then has
to appear in this list. Select the VAS 5054A the list and have the software discover the
services provided by the VAS 5054A (a Bluetooth serial port is the only service that is
allowed to be discovered). A prompt appears asking you to enter the PIN of the VAS 5054A.
Type in the serial number of the VAS 5054A, which is indicated on the ID plate.
4. Using the Bluetooth software, connect to the VAS 5054A. The connection may have already
been established during service discovery. A COM port for outgoing connections, which
was created by the Bluetooth software, is displayed on your PC. You will need the identifier
of this COM port when installing the application software.
5. Install the application software as described in sections 3.5 to 3.7.
6.3
FAQ 8
I get the error message: No EDIC is installed. What does that mean?
No VAS 5054A is currently installed. Connect to the VAS 5054A with your Bluetooth software.
Note down the COM port that your Bluetooth software has assigned to the VAS 5054A.
Install the VAS 5054A you want to use with your diagnostic application. You will find a detailed
description of how this is done in section 3.7.
FAQ 9
I get the error message The EDIC-API delivers a system error. In the details, the
error IFH-0002 (NO RESPONSE FROM INTERFACE) is indicated. What does that
mean?
The connection to the VAS 5054A has been interrupted. Possible reason:
The VAS 5054A was (temporarily) disconnected from the power supply during a diagnostic
session.
Plug the VAS 5054A back in. Click Aborting and restart your diagnostic session.
FAQ 10 I get the error message The EDIC-API delivers a system error. In the details, the
error IFH-0003 (DATATRANSMISSION TO INTERFACE DISTURBED) is indicated.
What does that mean?
The connection to the VAS 5054A has been interrupted. Possible reason:
The VAS 5054A was (temporarily) disconnected from the power supply during a diagnostic
session.
Plug the VAS 5054A back in. Click Aborting and restart your diagnostic session.
User Manual VAS 5054A V1.06
All rights reserved.
VAS 5054A User Manual
Page 33
После установки и запуска программы ODIS Service 3.1.3 у многих появляется с ней проблема — либо она не видела автомобиль и зажигание, либо всегда видела автомобиль и зажигание ПРИ ПОДКЛЮЧЕНИИ VAS5054 К АВТОМОБИЛЮ (когда вставлен в диагностический разъем!) но без ключа в замке зажигания.
Эти симптомы говорят о том, что драйвера установлены не правильно. Дело в том, что с этой версией ODIS идет новый внутренний драйвер для VAS5054, который многим не подходит к ПРИБОРУ.
Для проверки есть утилита Пуск -> Все программы -> Softing D-PDU API for VCIs V1.20.38 (либо бывают еще с другими версиями и двумя последними цифрами — 37, 35, 29, 23) -> Softing D-PDUAPI Test Application
.
1. Выбираем версию прошивки EDIC_D_PDU_API_1.20.038
2. Нажимаем Parse MDF File
3. В этом поле должен появится ваш диагностический модуль
4. Нажимаем кнопку PDUModuleConnect
5. Если все хорошо то в этом поле в конце будет написано
—————————————————-
Return of PDUGetResourceIds:
PDU_STATUS_NOERROR: PDU function call successful
—————————————————-
Number of matching resource IDs: 1
—————————————————-
Selected resource ID: 81
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
В случае если была ошибка
—————————————————-
Return of PDUModuleConnect:
PDU_ERR_FCT_FAILED: PDU Function call failed
.
Для обхода этой проблемы есть следующий способ. В папке ODIS_2.2.7VAS 5054A FIRMWARE UPGRATED-PDU_API’S есть установщик драйвера версии 1.20.23 (D-PDU_API V1.20.23.exe). Нужно его установить.
Затем зайти в каталог C:PROGRAM FILES (X86)SOFTINGD-PDU API 1.20.23VeCom и скопировать содержимое папки в каталог C:ODIS-DIAG-MODULESPDUAPIVEN-SOFTING1.20.23VeCom
Для версии ODIS ENGINEERING 6.6.1 скопировать папку в каталог C:ODIS-DIAG-MODULES-ENGINPDUAPIVEN-SOFTING1.20.23VeCom
После этого еще раз запускаем утилиту проверки и видим что драйвера и прошивка успешно ее проходят.
.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Запускаем программу и она успешно определяет автомобиль.
1/Без ключа в замке зажигания
2/С включенным зажиганием
Заранее скажу — В моем бортовом журнале CASA Sport$ а также Белуга 💯 будет много отчетов по ОДИСу, так что заходите в гости и подписывайтесь.
Спасибо всем кто дочитал до конца,
особенно тем кому НРАВИТСЯ блог и
нажал нужную кнопочку )