Error no pduapi module found

VAG ODIS 2.2.4 + Postsetup + FlashData 2015 (06-22-2015, 01:28 AM) vinha916 Wrote: you install 2.2.4 or upgrade from 2.2.3? Im trying to do a new install. Is this only upgrade? Because when i try to import data i it fails. Se attached image. (06-23-2015, 07:53 PM) Russel Wrote: Is it possible to flash […]

Содержание

  1. VAG ODIS 2.2.4 + Postsetup + FlashData 2015
  2. Odis-E cant see vas5054a
  3. Odis over Vas-PC (vas5054 v2 w/OKI chip)

VAG ODIS 2.2.4 + Postsetup + FlashData 2015

(06-22-2015, 01:28 AM) vinha916 Wrote: you install 2.2.4 or upgrade from 2.2.3?

Im trying to do a new install.
Is this only upgrade? Because when i try to import data i it fails.
Se attached image.

(06-23-2015, 07:53 PM) Russel Wrote: Is it possible to flash offline?? and how

Downloaded the 2.2.4 and install it like in video guide. all went just the same. only problem that the ODIS cannot see my clone 5054 . how do i get it to work ?

if i use my previous 2.0.2 everything work just fine. the 2.2.4 seem to have communication issue which does not allow the ODIS to «see» the 5054 (always via usb).

i used the PDU-API to test the communication but the drop down menu has only «XS_D_PDU_API_OS» which i think is the incorrect hardware :

Root description file contains 1 MVCI modules.

—————————————————-
Selected MVCI module: XS_D_PDU_API_OS
—————————————————-
PDU-API dll:
C:ODIS-DIAG-MODULESPDUAPIVEN-IMEPDUAPI_I+ME_ACTIA_XS.dll
PDU-API ModuleDescriptionFile:
C:ODIS-DIAG-MODULESPDUAPIVEN-IMEMDF_I+ME_ACTIA_XS.xml
PDU-API CableDescriptionFile:
C:ODIS-DIAG-MODULESPDUAPIVEN-IMECDF_I+ME_ACTIA_XS.xml
Loading PDU-API library file.

LoadLibrary Error:126
Error LoadLibrary(C:ODIS-DIAG-MODULESPDUAPIVEN-IMEPDUAPI_I+ME_ACTIA_XS.dll).
Trying LoadLibraryEx.
LoadLibraryEx succeeded.
Loading successful!
—————————————————-
Parsing MDF file.
MDF parser initialisation successful, MDF file loaded!
MDF parsing completed!
Fixing references completed!
Warning: ComParam value Overflow (Max or Min value is set) !
Warning: ComParam value Overflow (Max or Min value is set) !
Warning: ComParam value Overflow (Max or Min value is set) !
Warning: ComParam value Overflow (Max or Min value is set) !
Warning: ComParam value Overflow (Max or Min value is set) !
Warning: ComParam value Overflow (Max or Min value is set) !
Warning: ComParam value Overflow (Max or Min value is set) !
Warning: ComParam value Overflow (Max or Min value is set) !
—————————————————-
Parsing CDF file.
CDF parser initialisation successful, CDF file loaded!
CDF parsing completed!
—————————————————-
Return of PDUConstruct:
PDU_STATUS_NOERROR: PDU function call successful
—————————————————-
Return of PDUGetModuleIds:
PDU_STATUS_NOERROR: PDU function call successful
Error: No PduApi module found!

under the 2.0.2, the PDU-API has a different line in this drop down menu — «EDIC_D_PDU_API_1_20_012 » so when i choose it, it actually works.

Thanks a lot for great thread and help!!

(06-25-2015, 03:02 PM) yoll Wrote: i used the PDU-API to test the communication but the drop down menu has only «XS_D_PDU_API_OS» which i think is the incorrect hardware :

under the 2.0.2, the PDU-API has a different line in this drop down menu — «EDIC_D_PDU_API_1_20_012 » so when i choose it, it actually works.

Thanks a lot for great thread and help!!

Select the EDIC_D_PDU_API_OE or the EDIC_D_PDU_API_1_20_023 then click the Parse MDF File . It should detect and display VAS5054Softing AG xxxxxxxx (the xxxxx being your serial number) in the drop down. Then click PDUModuleConnect from there you can select the protocol and such.

Good luck
WOPR
Now I have a question for you ODIS Guru’s

I successfully installed ODIS E although the video would be much better if it was remade, slowed down and narrated. I work on computers all day and it was hard for even me to follow. But thanks for the great effort and support. I just think this would help with all of the same questions.

So my first question:

Is there a way to test the installation of ODIS-E using a VAS5054 and a Dummy CAN bus simulator? The reason I ask, is on the Diagnosis screen if I select any vehicle project then click the Vehicle Selection button (On any of the Project Options) I get a Fault

ODS4009E
Internal:
An internal system error has occurred. The system is unstable.
Please send a feedback and contact support
End system and restart.

I would think that at least the model selection would display but I know it can not connect to the car. Is this normal operation with no actual connection or wrong car detected?

Also Question #2.

If I want to reRun the ODX Update then how is this done. Do I delete the Files under the DSVR-ProdiMCD folder in MCD-Projects-Engineering

(06-25-2015, 03:02 PM) yoll Wrote: i used the PDU-API to test the communication but the drop down menu has only «XS_D_PDU_API_OS» which i think is the incorrect hardware :

under the 2.0.2, the PDU-API has a different line in this drop down menu — «EDIC_D_PDU_API_1_20_012 » so when i choose it, it actually works.

Thanks a lot for great thread and help!!

Select the EDIC_D_PDU_API_OE or the EDIC_D_PDU_API_1_20_023 then click the Parse MDF File . It should detect and display VAS5054Softing AG xxxxxxxx (the xxxxx being your serial number) in the drop down. Then click PDUModuleConnect from there you can select the protocol and such.

Dear WOPR, thanks for your quick respond !!
My problem is that in the drop down menu i can only select «XS_D_PDU_API_OS»

it happen on both 1.20.023 and 1.20.020.
however if i install ODIS 2.0.2 which have 1.20.012, the drop down menu have only EDIC_D_PDU_API_somethimg and it works ok.
looks like this drop down menu is dependent of the ODIS itself rather than the 1.20.xxx driver installation.

i have found that if i change the file : «C:ProgramDataD-PDU APIpdu_api_root.xml» so it points to EDIC_D_PDU_API_1_20_012.dll or EDIC_D_PDU_API_1_20_020.dll or EDIC_D_PDU_API_1_20_023.dll instead of «PDUAPI_I+ME_ACTIA_XS.dll — the result is that the PDU-API Test application will work and show good communication to the 5054 ( i also made sure the 1.20.023, 1.20.020 and 1.20.012 libraries are inside C:ODIS-DIAG-MODULESPDUAPIVEN-SOFTING ) :

Root description file contains 1 MVCI modules.

—————————————————-
Selected MVCI module: EDIC_D_PDU_API_1_20_012
—————————————————-
PDU-API dll:
C:ODIS-DIAG-MODULESPDUAPIVEN-SOFTING1.20.012vecomPDUAPI_SoftingAG_1.20.012.dll
PDU-API ModuleDescriptionFile:
C:ODIS-DIAG-MODULESPDUAPIVEN-SOFTING1.20.012vecomMDF_SoftingAG_EDIC-PDU-API_1.20.012.xml
PDU-API CableDescriptionFile:
C:ODIS-DIAG-MODULESPDUAPIVEN-SOFTING1.20.012vecomCDF_SoftingAG_EDIC-PDU-API_1.20.012.xml
Loading PDU-API library file.

PduApiLibPath:»C:ODIS-DIAG-MODULESPDUAPIVEN-SOFTING1.20.012vecomPDUAPI_SoftingAG_1.20.012.dll»
Loading successful!
—————————————————-
Parsing MDF file.
MDF parser initialisation successful, MDF file loaded!
MDF parsing completed!
Fixing references completed!
Warning: ComParam value Overflow (Max or Min value is set) !
Warning: ComParam value Overflow (Max or Min value is set) !
Warning: ComParam value Overflow (Max or Min value is set) !
Warning: ComParam value Overflow (Max or Min value is set) !
Warning: ComParam value Overflow (Max or Min value is set) !
Warning: ComParam value Overflow (Max or Min value is set) !
Warning: ComParam value Overflow (Max or Min value is set) !
Warning: ComParam value Overflow (Max or Min value is set) !
Warning: ComParam value Overflow (Max or Min value is set) !
—————————————————-
Parsing CDF file.
CDF parser initialisation successful, CDF file loaded!
CDF parsing completed!
—————————————————-
Return of PDUConstruct:
PDU_STATUS_NOERROR: PDU function call successful
—————————————————-
Return of PDUGetModuleIds:
PDU_STATUS_NOERROR: PDU function call successful
—————————————————-
Number of modules found: 6
hMod: 1, ModuleStatus: PDU_MODST_AVAIL,
Module Type ID: 542,
Vendor Module Name: Type=’MVCI_ISO_13400_DoIP_Vehicle’ VIN=’VEHICLEVIN0000001′,
Vendor Additional Info: Count=’002′
LA000=’0x4010′ IP000=’192.168.000.030′ EID000=’0x0A0A0A0A0A0A’ GroupID000=’0x010101010101′
LA001=’0x1001′ IP001=’192.168.150.183′ EID001=’0x0B0B0B0B0B0B’ GroupID001=’0x010101010101′

hMod: 2, ModuleStatus: PDU_MODST_AVAIL,
Module Type ID: 531,
Vendor Module Name: VendorName=’Softing AG’ ModuleName=’VAS5054′ SerialNumber=’082145725′,
Vendor Additional Info:
hMod: 3, ModuleStatus: PDU_MODST_AVAIL,
Module Type ID: 527,
Vendor Module Name: VendorName=’Intrepid’ ModuleName=’Intrepid’ J2534 Standard Version=’4.04′,
Vendor Additional Info:
hMod: 4, ModuleStatus: PDU_MODST_AVAIL,
Module Type ID: 527,
Vendor Module Name: VendorName=’Intrepid’ ModuleName=’Intrepid neoVI Fire/Red’ J2534 Standard Version=’4.04′,
Vendor Additional Info:
hMod: 5, ModuleStatus: PDU_MODST_AVAIL,
Module Type ID: 527,
Vendor Module Name: VendorName=’Intrepid’ ModuleName=’Intrepid neoVI Yellow’ J2534 Standard Version=’4.04′,
Vendor Additional Info:
hMod: 6, ModuleStatus: PDU_MODST_AVAIL,
Module Type ID: 527,
Vendor Module Name: VendorName=’Intrepid’ ModuleName=’Intrepid ValueCAN3′ J2534 Standard Version=’4.04′,
Vendor Additional Info:
—————————————————-
Return of PDUModuleConnect:
PDU_STATUS_NOERROR: PDU function call successful

—————————————————-
Module Short Name : Type=’MVCI_ISO_13400_DoIP_Vehicle’ VIN=’VEHICLEVIN0000001′
Module Vendor Name : Softing Automotive Electronics GmbH
Module HwName : DoIP_Vehicle
Module SerialNumber : 0
Module FW Name : VeCom
Module FW-Version : 2.20.12
Module FW-Date : 18.4.2013 (Calendar week 16)
Module PDU-API SW Name : Softing D-PDU API for VCIs
Module PDU-API Version : 1.20.12
Module PDU-API SW Date : 18.4.2013 (Calendar week 16)
—————————————————-
Return of PDUGetResourceIds:
PDU_STATUS_NOERROR: PDU function call successful
—————————————————-
Number of matching resource IDs: 1
—————————————————-
Selected resource ID: 225
—————————————————-
Return of PDUGetResourceIds:
PDU_STATUS_NOERROR: PDU function call successful
—————————————————-
Number of matching resource IDs: 1
—————————————————-
Selected resource ID: 225

so far so good.
however, when i go to ODIS, i yet have no link to the 5054 :

any clues what may make the ODIS link to the 5054 ?

Источник

Odis-E cant see vas5054a

Im trying to install odis-e 12.2.0 but I have a problem that odis-e cant find my vas5054.

I have previously installed odis-s and in pdu-api test application i can see only «EDIC_D_PDU_API_OS» and «XS_D_PDU_API_OE». When i check API_OS its working fine but when i check XS_D_PDU_API_OE its just saying «error no PduApi module found!» Im trying to install it on windows 7 ultimate.

does anyone know what im missing here?

(11-21-2021, 07:26 PM) hs82 Wrote: Im trying to install odis-e 12.2.0 but I have a problem that odis-e cant find my vas5054.

I have previously installed odis-s and in pdu-api test application i can see only «EDIC_D_PDU_API_OS» and «XS_D_PDU_API_OE». When i check API_OS its working fine but when i check XS_D_PDU_API_OE its just saying «error no PduApi module found!» Im trying to install it on windows 7 ultimate.

does anyone know what im missing here?

1. Take — its a general aspect. — WIN10 64 bit —
The newer versions of ODIS S and ODIS E are only for WIN10 — win7 is not supported anymore .

2. You will need to copy the plugins that you became with the ODIS E installer (cracked versions for clone VAS5054A) inside the plugins folder of ODIS E

Источник

Odis over Vas-PC (vas5054 v2 w/OKI chip)

(01-04-2016, 05:22 AM) 153771739 Wrote: Quote (Mr. fantomel) : » BEFORE ODIS INSTALL :
HymeHW.dll located in C:SIDIShomebin
Make a backup for the actual file also . «

Good day!
One say do that so . Others say — do the opposite .
So , very well . )))
I do not ask how to do it . It’s written everywhere . I ask why do so .

1) Need (or no) to install VAS UDS additional exe files ?

Answer : (For VAS-PC v19 and WinXP)

For old Adapter = VID_077E&PID_0220 = Not Need
Device Name = Softing Vehicle Interface VAS5054
DRV = C:/SIDIS/home/DBaseSys2/Driver/EDIC/win2000 (Default VAS-PC v19)

For new adapter ( v2.05 ) = VID_0403&PID_6001 = Need .
Device Name = VAS5054 BUS
DRV = REQUIRED = VAS5054A UDS Redist Drivers Package
After Install Drv Path = C:Program FilesVCIUSB

2) Default D-PDU API = v1.10 (for Vas-Pc v19.01.01) .
Need (or no) update it to v1.23 ?

Answer : (may be for ODIS only . )
Good China adapter must work to API 1.35
Bad China adapter don’t work after API 1.20 . 1.23
Version reduced if the adapter can not communicate with the car .
For change path = may be here ? : pdu_api_root.xml

3) Will both of these programs work on the same PC ?

Answer : Yes, if the condition is fulfilled .
3a = Adapter VAS5054 have the same setting in both soft’s
3b = ImporterID , DealerID have the same setting in both soft’s
3c = If VAS-PC v19.01.01 = It should be no problem .
3d = If VAS-PC NOT v19.01.01 = Install VAS-PC, ODIS, Re-Install VAS-PC (or recovery)

4) What should I do before starting the installation ?

Answer : for ODIS ; nothing special . Clean new OS Win7 .
Install Java j2sdk-1_4_2_15 or j2re-1_4_2_15 (reccomended by VAG)
Edit License (to match to PC)
Best regards,
Dmitry

Good day!
Here I want to consider need or not = to downgrade version of the API
This info for ODIS v2.2.7 and VAS5054 v2.05 new adapter .
For case : VAS5054 don’t connect via USB ; don’t read few ECU of car . (a few ECU is reads) .

Install new win7 and ODIS v227 ps670180 .
Connect VAS5054 via USB .
Drivers installed automatically .
But not for USB . For Bluetooth . Although port for BT can see as real for USB .
Check : PDU_ERR_FCT_FAILED: PDU function call failed

Connect VAS5054 via Bluetooth .
Check : PDU_ERR_FCT_FAILED: PDU function call failed

Good . Will downgrade version D-PDU API .

PATH = СProgram FilesSoftingD-PDU API
PATH OLD = CODIS-DIAG-MODULESPDUAPIVEN-SOFTING
PATH CONFIG = C:/ProgramData/D-PDU API/pdu_api_root.xml

D-PDUAPI_Test.exe = C:Program FilesSoftingD-PDU API1.xx.xxxpduapitestD-PDUAPI_Test.exe

Change D-PDU API Version Instruction
Example from 1.20.029 to 1.20.020 .

Install D-PDU API v1.20.020
Goto C:/ProgramData/D-PDU API/
Copy and save in other location as pdu_api_root_1.20.029.xml
Open in notepad
Save as pdu_api_root_1.20.020.xml
Replace all 1_20_029 to 1_20_020
Replace all 1.20.029 to 1.20.020
Save
Save as pdu_api_root.xml and close
Copy pdu_api_root.xml and replace to C:/ProgramData/D-PDU API/
Restart PC

Now open D-PDUAPI_Test.exe
and you will see (select) that now ver = 1.20.020
check adapter :
select EDIC_D_PDU_API_1_20_020 => Load successful !
Parse MDF File => MVCI Module VAS5054 Softing AG xxxxxxxxx
=> PDU_STATUS_NOERROR: PDU function call successful
=> Module Type ID: 531
PDUModuleConnect =>
=> Return of PDUModuleConnect:
=> PDU_ERR_FCT_FAILED: PDU function call failed

THIS WAY IS NOT GOOD . WILL DO NEXT .

Goto Softing D-PDU API for VCIs V1.20.020 => EDIC Configuration Manager
Delete Adapter .

Then I check driver version .
C:Program FilesSoftingEdicDriverwin7 .
Of course . This for old adapter . SOFTINGEDIC7_NTx86.INF .
%DESC_5054%=DI_EUSB,USBVID_077E&PID_0220

Not only for VAS-PC . ODIS also required to install VAS UDS Redist Drivers .
Not (VAS-PC or ODIS) , but VAS5054 new adapter required this drivers .
Install it .
Do not run AutoSetup ; Install step by step . As Admin .
01 VAS_UDS_Redist
02 DATA20130325
03 DATA20130402
04 UDS_VW_SKODA_v1.2
05 UDS_VW_SKODA_v1.4
Reboot PC

PC => Bluetooth => switch OFF
Start => My PC => Device Mgr => Radio BT => Generic BT Adapter => OFF
Connect VAS5054 to OBD next to USB .
Unknown Device => Auto Search and Install Drivers => Found VAS5054 BUS => REQUIRED RESTART PC .
Reboot PC

Start => D-PDUAPI_Test.exe
PDU_STATUS_NOERROR: PDU function call successful
Error: No PduApi module found!
=> Not possible to select MVCI Module . ( . )

Check VAS5054 BUS driver version => = 2.8.28.0
Update driver . STOP . Don’t use update because it for old adapter . What’s to do .

Start > All Program > Softing D-PDU API for VCIs V1.20.020 > EDIC Hardware Installation
Add EDIC => Select VAS5054 > Added .

Start > All Program > Softing D-PDU API for VCIs V1.20.020 > EDIC Configuration Manager
VAS5054 S# xxxxxxxxxx
Bluetooth Port : COM4

Start => D-PDUAPI_Test.exe
EDIC_D_PDU_API_1_20_020 => Load successful !
Parse MDF => MVCI = VAS5054 Softing AG xxxxxxxxx => Module Type ID: 531
PDUModuleConnect .
Return of PDUModuleConnect:
PDU_ERR_FCT_FAILED: PDU function call failed

ODIS also not works . Error date structure .
Switch back to v1.20.029
Start API Test
. SEE NOTE => Vendor Additional Info: ConnectionType=’Bluetooth’
. Is this means that driver is crookedly . Do not support USB always .
PC > BT > SET ON
Connect adapter via BT .

A brief note :
I read somewhere the instruction .
When install the adapter for Bluetooth .
Will be allocated 2 ports (for example) an outbound port 5; Incoming Port 6 .
For VAS5054 use as a port for installing = last port . In this case, the incoming port 6 .
Additionally = EDIC Hardware Configurator lets you do this .
However, this advice does not work . usually work ports must be port 5 .

Open BT > Setting > Check = InComing Connection . (checked)
Return of PDUModuleConnect:
PDU_ERR_FCT_FAILED: PDU function call failed .

This adapter bad work and for VAS-PC .
I think — that the adapter is defective .
Or the Chinese people at this time — much too clever by half .
Best regards,
Dmitry

Источник

  • Realtime Posts
  • Downloads
  • Chatbox
  • Donate Crypto
  • What’s New?
  • Forum
    • New Posts
    • FAQ
    • Calendar
  • Satellite Forums
  • Garage Forum
  • Cable Forum
  • Apple Forum
  • Android Forum
  • Donate Crypto

Register

  • Home
  • Forum
  • The Garage
  • Commercial/Industrial/Agricultural
  • Diagnostic/Workshop
  • ODIS 2.2.3 + PostSetup 6.20.25

  1. 16th April, 2015, 07:44 AM


    #1

    Aleck is offline


    Newbie


    Default ODIS 2.2.3 + PostSetup 6.20.25

    ODIS 2.2.3 + PostSetup 6.20.25(Multilingual)FREE. NO PASS.
    I don’t understand why people put password and ask thanks. All thanks should go from the heart.

    Working well. Tested by my own.

    ODIS_2.2.3.rar


  2. The Following 16 Users Say Thank You to Aleck For This Useful Post:

    admiralx (25th April, 2015), antsus1000 (17th December, 2015), bukolit (15th May, 2015), DOCKERS (25th June, 2015), engert (15th May, 2015), flor (29th April, 2015), gelencserg (3rd May, 2015), jakesman (27th April, 2015), jihyu (14th November, 2015), jm6734 (14th April, 2017), makura (22nd April, 2015), mrbellman (9th May, 2015), piscinarasx (28th April, 2015), tomushas (16th April, 2015), yvespapou (11th May, 2015), zirafin (1st October, 2015)


  3. 24th June, 2015, 07:55 PM


    #2

    Default

    Hi and thank you for your info!!!

    i downloaded everything. all ODIS installation is quite simple.
    just one thing — i cannot make the hardware (VAS5054A) installation.
    i get the following in the PDU-API test applicaion :

    ************ Getting MVCI Module paths *************

    Root description file contains 1 MVCI modules.

    *********** Changing the PDU-API module ************

    —————————————————-
    Selected MVCI module: XS_D_PDU_API_OS
    —————————————————-
    PDU-API dll:
    C:ODIS-DIAG-MODULESPDUAPIVEN-IMEPDUAPI_I+ME_ACTIA_XS.dll
    PDU-API ModuleDescriptionFile:
    C:ODIS-DIAG-MODULESPDUAPIVEN-IMEMDF_I+ME_ACTIA_XS.xml
    PDU-API CableDescriptionFile:
    C:ODIS-DIAG-MODULESPDUAPIVEN-IMECDF_I+ME_ACTIA_XS.xml
    Loading PDU-API library file…

    PduApiLibPath:»C:ODIS-DIAG-MODULESPDUAPIVEN-IMEPDUAPI_I+ME_ACTIA_XS.dll»

    LoadLibrary Error:126
    Error LoadLibrary(C:ODIS-DIAG-MODULESPDUAPIVEN-IMEPDUAPI_I+ME_ACTIA_XS.dll).
    Trying LoadLibraryEx…
    LoadLibraryEx succeeded.
    Loading successful!
    —————————————————-
    Parsing MDF file…
    MDF parser initialisation successful, MDF file loaded!
    MDF parsing completed!
    Fixing references completed!
    Warning: ComParam ID=3, value Overflow (Max or Min value is set) !
    Warning: ComParam ID=33, value Overflow (Max or Min value is set) !
    Warning: ComParam ID=34, value Overflow (Max or Min value is set) !
    Warning: ComParam ID=36, value Overflow (Max or Min value is set) !
    Warning: ComParam ID=86, value Overflow (Max or Min value is set) !
    Warning: ComParam ID=89, value Overflow (Max or Min value is set) !
    Warning: ComParam ID=91, value Overflow (Max or Min value is set) !
    Warning: ComParam ID=128, value Overflow (Max or Min value is set) !
    —————————————————-
    Parsing CDF file…
    CDF parser initialisation successful, CDF file loaded!
    CDF parsing completed!
    —————————————————-
    Return of PDUConstruct:
    PDU_STATUS_NOERROR: PDU function call successful
    —————————————————-
    Return of PDUGetModuleIds:
    PDU_STATUS_NOERROR: PDU function call successful
    Error: No PduApi module found!

    ************************************************** *************

    what am i missing ?

    i know that my clone (chinese) 5054A is good as i can use it with the 2.0.2 ODIS with no problem.

    Thanks a lot for any further help!!


  4. 25th August, 2015, 11:26 PM


    #3

    usiex is offline


    Newbie


    Default

    Hi I need links to ODIS 2.2.3+postestup 6.20.25 on fast servers not torrent links
    Thanks


  5. 22nd November, 2015, 12:47 AM


    #4

    Default

    PostSetup6.70.180.txt

    POSTSETUP 6.70.180 for 2.2.6/2.2.7

    If a man goes on a seven-day trip, he?ll pack five days worth of clothes and will wear some things twice; if a woman goes on a seven-day trip she?ll pack 21 outfits because she doesn?t know what she?ll feel like wearing each day.


  6. 27th November, 2015, 06:10 PM


    #5

    Default

    Can i make flashing modules with Alecks 2.2.3 version odis?


  7. 27th November, 2015, 06:21 PM


    #6


  8. 27th November, 2015, 06:45 PM


    #7

    Default

    Quote Originally Posted by Aleck
    View Post

    you need odis-e

    I installed version 5.xxxx E, but in edic configuration manager i see «device is not accessible». Also in Odis is » no hardware available». I got Bluetooth-port com 8 in softing edic configuration menager. I heard that is problem with VAS head firmware. My VAS contain all parts on the boards, also oki chip.
    Any help?
    I got firmware but no idea how to update.
    VAS5054.rar

    Last edited by JareckiPL; 27th November, 2015 at 08:10 PM.


 

Bookmarks

Bookmarks


Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
  • BB code is On
  • Smilies are On
  • [IMG] code is On
  • [VIDEO] code is On
  • HTML code is Off

Forum Rules

All times are GMT +1. The time now is 03:50 PM.

Powered by vBulletin® Version 4.2.5
Copyright ©2000 — 2023, Jelsoft Enterprises Ltd.

vBulletin Optimisation provided by
vB Optimise (Pro) —
vBulletin Mods & Addons Copyright © 2023 DragonByte Technologies Ltd.

Digital Kaos does not condone any illegal operations, including obtaining premium tv for free. Digital Kaos does not accept responsibilty for the loss of any equipment used.
Everything discussed on this forum is for experimental and educational purposes only. Use the information at your own risk.

vBulletin Skin By: PurevB.com

Содержание

  1. 25. Китайский VAS5054A и установка ODIS (Service 7.1.1 & Engineering 12.2)
  2. VAS 5054 VAS PC установка
  3. VAS5054 — Инструкция о правильной установке драйверов
  4. Установка VAS-PC на Win7x64 без виртуальной системы, напрямую
  5. Установка и подключение VAS PC 5054A
  6. Подготовка к установке vas 5054a
  7. Установка 19.01
  8. Марочный диск
  9. Установка флеш диска
  10. Установка драйверов для устройства VAS5054A

25. Китайский VAS5054A и установка ODIS (Service 7.1.1 & Engineering 12.2)

dkAAAgLX OA 100

Все выходные провел ковыряясь в VAS5054a и ODIS-S/E.

Покупка VAS5054
Сам китайский клон адаптера VAS5054a я приобрел тут:
_aliexpress.ru/item/138612…127288&sku_id=66920011198 за 6300 руб (цена 6800, но у меня был купон на 500 руб).
Нормальную оперативную память (K6R4016C1D-UI10) на 5В
_aliexpress.ru/item/32829323715.html за 290 руб

Описание с али гласило, что в адаптере должно быть:
SAF-XC167CI-32F40F (167, но хотя бы на 40 Гц)
SAMSUNG K6T4016V3C-TB70 на 3В (поэтому и заказывал сразу память на 5В)
Оригинальный OKI M6636 (который мне, по сути, не нужен)

Имееется куча отзывов, что все супер, однако это не так. Дело в том, что все отзывы пишутся людьми не вникающими в суть. Они ставят ODIS от продавца с уже патченым PDU, так что вроде как работает, но качество адаптера на самом деле — хрень.

Что пришло мне:
SAF-XC167CI-16F20F
Память от Fujitsu 29F160BE-90PFTN
SAMSUNG K6X4016C3F-UF55
Фальшивый OKI (внешне он очень похож на оригинал, но диод стоит в неправильном положении и внутреннее кольцо ключа не глянцевое)
КРЕНка вместо регулятора напряжения LTAEF (LT3010HMS8E-5)

То есть медленный чип на 20 ГЦ и 5В оперативная память, на которую на самом деле подается 3В (хз, как оно так работает, но вроде я верно замерил мультиметром) UPD 10.09.2022 подается 5В, дело было в разряженном аккумуляторе (я проверял на столе). Я сразу дополнительно заказывал K6R4016C1D-UI10 на 5В, так как думал, что будет стоять память на 3В, но пришла память на 5В и теперь думаю, есть ли смысл ее менять. Так же видимо придется докупать нормальный микроконтроллер.
Из плюсов — хорошее качество пайки.
Прибор полностью разобрал и сфоткал со всех сторон.

4Hb5 7oOlZyz3b1qZUOKqsnRnyg 960

3ujzvcu0JbvgrP6UqEOUBDiy578 960

zBrspB1B3CA37a81NsQ6eam2s60 960

NCJxooHdGrl8WRqqyoNKaiHNJmY 960

RShbveH QuMAAzPb9TMMmthV1MM 960

Bh8tsKVdDKOvQ32HrUvNEfhiX0U 960

Установка ODIS
Действительно ставится весь софт не совсем очевидно, к тому же нет единой инструкции, подходящей всем.

В итоге после запуска Softing D-PDUAPI Test Application мы должны увидеть:
EDIC_D_PDU_API_OE
EDIC_D_PDU_API_OS

18R 8l34js1KXvHbn VAFomRSd4 960

Первый будет значить, что ODIS E сможет подключиться к адаптеру, а второй, что ODIS S.

Так как у меня китайский клон, то естественно, что без патчей он проверку PDU 42 не прошел, а при первом нажатии PDUModuleConnect выдавалась ошибка:
PDU_ERR_MODULE_FW_OUT_OF_DATE: Firmware software out of date.
Если нажать повторно, то проверка значилась вроде как успешная, но к машине подключиться не получалось (выдавалась ошибка ODS4009E).

Видео с проведением проверки в Softing D-PDUAPI Test Application:

Поэтому скачиваем тут PDU-42_patch v3 (любые флеш, TJA1054, OKI 6636).zip, все заменяем, согласно инструкции:
Для копирования папки пути следующие:
Для 64-битной системы путь такой:
C:Program Files (x86)SoftingD-PDU API1.20.042VeComVAS5054

делаем проверку, которая теперь проходит успешно с первого раза.

i0jy TYuNju lee5AyDiBQ3Q6Sc 960

И получаем полностью рабочие ODIS S и E.

KoqrsCz7mYmf2Nod xfwOeCRj4w 960

Проект в ODIS для Skoda Octavia A7 FL — SK37X.

Выводы:
Вообще адаптер я брал с целью обновления блоков (двигатель, коробка и др), но я сначала заказал, а потом начал смотреть наличие этих самых обновлений.а их нет, видимо слишком свежая машина еще. Блоки, собственно, не прошивал, но думаю с этой задачей этот кривой клон VAS5054A должен справиться.
Буду открывать диспут на али и пытаться вернуть хотя бы 1-2к, посмотрим, что из этого выйдет.
Приятный UPD 10.09.2022:
Собственно подал диспут, но не на 1-2к, а на 50% стоимости, т.е. 3.4к (от изначальной цены 6.8к, несмотря на купон и итоговую цену для меня 6.3к). Я приложил скриншоты с выделением другого микроконтроллера, оперативки, указал, что OKI — кривой, а не оригинал (на одном из фото в описании заказа, почему то, оказался диод VD7 в правильном положении — это фото и использовал для сравнения), а продавец даже ничего не ответил и в итоге спор ТП алиэкспресса отдала полностью в мою пользу.
Причем самому продавцу я описывал претензии в обычном чате, но он решил мне ничего не отвечать, кроме: посмотрите внимательнее описание заказа.

Источник

VAS 5054 VAS PC установка

9eff9c2s 100

f06dde4s 960

0. Качаем или не качаем ORACLE VM. Создаем виртуальную машину.
1. Качаем: Windows XP SP3 eng (rutracker.org/forum/viewtopic.php?t=4461985) + Russian MUI For Windows XP 32-bit SP0-SP3 (если нужен)
2. Устанавливаем Java SE Development Kit 7u2-win-x86.exe
3. Устанавливаем Эмулятор (например Alcohol 120%)
4. Устанавливаем VAS PC v.19.01RU + таблетка Crack_19.01 (ADM.ехе copy :SIDIShomebin)
5. Тыкаем ярлык VAS PC на рабочем столе ОДИН РАЗ!
6. Тыкаем Admin / Вводим идентификатора станции (Любой номер); Номер импортера (935), Номер предприятия (00255), нажимаем «Q».
7. Монтирует в виртуальный привод марочник Skoda 19.47 (у меня стоит и 19.61 они друг друга дополняют, я их к друг другу привязал, как не скажу =) ). Так же потом устанавливайте марочник Audi 19.50
8. Заходим в выполнить / regedit далее HKEY_LOCAL_MACHINESOFTWARESIDISENV — THE_REAL_CDROOT – указываем букву CDROM (каждый раз придется менять, при установки/обновления марочника).
9. Переходим обратно в VAS — Админ — Обновлениеустановка с диска. Установили.
10. Вставляем VAS в порт авто, подключаем его с ноутом, через провод, автоматически устанавливаются драйверы.
11. Далее проверяем, идем по адресу: C:SIDIShomeDBaseSys2EIDBSSEAConfig.еxе тыкаем, должно быть запись «Any EDIC» «All applications».
12. Так же проверяем по адресу C:SIDIShomeDBaseSys2DRIVEREDIChwconfig.eхe должна быть запись «VAS 5054-USB-SERIAL Number». Все.
13. Запускам VAS PC.

p/s/ Добавлено 2016 год.
Если вылазит ошибка «EDIC не инсталлирован» после присоединения ШНУРКА, то
1.Запуск программы «EDIC Hardware Installation».
2.Клик по кнопке «Add EDIC». Выбрать пункт меню «VAS 5054» и кликнуть по «OK».
3. Запуск программы «EDIC Software config»
4. Кликнуть «Add EDIC» и кликнуть «ОК»

Чтобы не бегать по инету и ничего не искать, то большинство файлов Java, марочники, базы берем у уважаемого sanchopanso998
disk.yandex.ru/public/?ha…T7cxTSgHGp/7gi4KnaZ8vs%3D

Установка связи VAS PC c VAS5054 посредством Bluetooth — (самое сложное).

Я для интереса пробовал и TOSHIBA Bluetooth Stack 5,8,9 версии. Не работает. Просто не видит VAS5054. Так же пробовал прописать VID и PID в настройках TOSHIBA, Результат не удачен. Пришлось устанавливать BlueSoleil 1.6 версия. Так же советую найти нормальный блюпуп, а не китайский.

Источник

VAS5054 — Инструкция о правильной установке драйверов

380d8bes 100

21245bas 960

a5b9bas 960

После установки и запуска программы ODIS Service 3.1.3 у многих появляется с ней проблема — либо она не видела автомобиль и зажигание, либо всегда видела автомобиль и зажигание ПРИ ПОДКЛЮЧЕНИИ VAS5054 К АВТОМОБИЛЮ (когда вставлен в диагностический разъем!) но без ключа в замке зажигания.

Эти симптомы говорят о том, что драйвера установлены не правильно. Дело в том, что с этой версией ODIS идет новый внутренний драйвер для VAS5054, который многим не подходит к ПРИБОРУ.

165b9bas 960

1. Выбираем версию прошивки EDIC_D_PDU_API_1.20.038
2. Нажимаем Parse MDF File
3. В этом поле должен появится ваш диагностический модуль
4. Нажимаем кнопку PDUModuleConnect
5. Если все хорошо то в этом поле в конце будет написано
—————————————————-
Return of PDUGetResourceIds:
PDU_STATUS_NOERROR: PDU function call successful
—————————————————-
Number of matching resource IDs: 1
—————————————————-
Selected resource ID: 81

В случае если была ошибка
—————————————————-

Return of PDUModuleConnect:
PDU_ERR_FCT_FAILED: PDU Function call failed

f65b9bas 960

Для обхода этой проблемы есть следующий способ. В папке ODIS_2.2.7VAS 5054A FIRMWARE UPGRATED-PDU_API’S есть установщик драйвера версии 1.20.23 (D-PDU_API V1.20.23.exe). Нужно его установить.
Затем зайти в каталог C:PROGRAM FILES (X86)SOFTINGD-PDU API 1.20.23VeCom и скопировать содержимое папки в каталог C:ODIS-DIAG-MODULESPDUAPIVEN-SOFTING1.20.23VeCom

Для версии ODIS ENGINEERING 6.6.1 скопировать папку в каталог C:ODIS-DIAG-MODULES-ENGINPDUAPIVEN-SOFTING1.20.23VeCom

После этого еще раз запускаем утилиту проверки и видим что драйвера и прошивка успешно ее проходят.

3f9ab0ds 960

Запускаем программу и она успешно определяет автомобиль.

Источник

Установка VAS-PC на Win7x64 без виртуальной системы, напрямую

380d8bes 100

23af46s 960

Суть методы проста: VAS-PC при установке пытается пошебуршить в системных делах, право на которые имеет только «TrustedInstaller».

Соответственно система это пресекает.

Отсюда вывод — провести установку от имени «Trustedinstaller»-а, и не из проводника Windows,

проводник не позволит, а из Тоталкоммандер-а (или Фар-а, у меня Тотал, Фар не пробовал но думаю пойдет).

Тоталкоммандер (или Фар).

Программа «devxexec.exe» — она и позволит запускать Тотал или Фар от имени «Trustedinstaller»-а.

Если Win7x32, то скопируйте файл «devxexec.exe» в папку «C:WindowsSystem32»

Если Win7x64, то скопируйте файл «devxexec.exe» в папки: «C:WindowsSystem32» и «C:WindowsSysWOW64»

Отредактируйте разрешения (Свойства-Безопасность) для этого файла по аналогии

с соседними системными файлами (в целях типа безопасности. чтобы добавить «TrustedInstaller» в разрешения для объекта

нажмите кнопку Другие пользователи или группы… и в качестве имени объекта в текстовом поле введите: NT ServiceTrustedInstaller ).

Теперь можно запустить от имени «TrustedInstaller» различные программы:

Пример на Registry Workshop:

Выполнить из меню Пуск (Win+R)

Ввести команду: devxexec.exe /user:TrustedInstaller «C:Program FilesRegistry WorkshopRegWorkshopX64.exe»

Можно просто отредактировать в ярлыках программ путь к исполняемому файлу, добавив в начало пути

Пример для ярлыка программы Registry Workshop:

devxexec.exe /user:TrustedInstaller «C:Program FilesRegistry WorkshopRegWorkshopX64.exe»

(кавычки нужны, если путь к файлу содержит пробелы).

Обязательно полностью указать путь к программе, которую хотите запустить от имени «TrustedInstaller».

Копируем дистрибутив VAS-PC скажем на диск «D:»

В свойствах файлов

выбираем «Совместимость»— «Изменить параметры для всех пользователей» (для страховки, поскольку установка будет не от текущего пользователя)

ставим «галки» «Совместимость с WinXP_SP3» и «Выполнять от имени администратора».

У файла «VAS-PC_RT.msi» — «совместимость с предшествующей версией Windows».

Теперь запускаем Тотал или Фар от имени «TrustedInstaller»-а, выбираем в нем файл установки VAS-PC «setupstart.exe»

По окончании установки необходимо перенести в реестре раздел «SIDIS» (целиком)

из «HKEY_LOCAL_MACHINESOFTWARE» в «HKEY_LOCAL_MACHINESOFTWAREWow6432Node»

Далее все как при установке на WinXP.

После установки VAS-PC на W7x64, в свойствах всех батников и ехе-шников, что VAS поставил, целесообразно установить атрибуты-«галки» — «для всех пользователей» — «Совместимость с WinXP_SP3» и «Выполнять от имени администратора».

Потратить время, но подстраховаться от неожиданностей и каверз.

Ну и не забываем для программы правильно пристроить прибор VAS5054 — Инструкция о правильной установке драйверов

Источник

Установка и подключение VAS PC 5054A

Покупал сканер на Али, вот ссылка http://ali.pub/3v6njv. Также этот прибор можно использовать и с программой ОДИС.

Я решил установить на отдельный комп с Win ХР, так как старенький НетБук ASUS имеется, и как раз подходит для роли автомобильного компьютера.

Подготовка к установке vas 5054a

Установил на нетбук операционную систему Windows xp sp2 и поставил дополнительный пакет обновлений sp3.

Для начала необходим виртуальный диск на компьютере, так как все установочные диски в виде образов. Я использую программу DaemonTools Lite (https://yadi.sk/d/aDOhvckqceMJc). При установке выберете «Бесплатную версию», прога коротенькая, но всё самое необходимое имеет.

Теперь можно установить JAVA, без неё vas не будет работать. Скачивайте папку Java: (https://yadi.sk/d/nP3O9U99ceLxu) запускаете установочный файл (jre-6u23-windows-i586.exe). Теперь необходимая Джава есть на Вашем компьютере, идём дальше.

Установка 19.01

Теперь качаем папку TAB: (https://yadi.sk/d/iAsg41Cnivgoc) и берём из неё файл (ADM.exe) и копируем его с замещением в папку на компе, куда установилась прога.: C:SIDIShomebin
Установка закончена, делаем перезагрузку системы!

Марочный диск

install vas ps

Установка флеш диска

Как я понял ФЛЕШ диск нужен для обновления программного обеспечения мозгов авто. При внесении изменений каких-либо настроек или диагностики, с помощью VAS PC, если ПО автомобиля будет устаревшим, прога автоматически предложит обновить его. (Читал на форуме Touareg, у одного товарища после обновления ПО, двигатель запел новыми нотами).

Опытные ребята рекомендуют Флеш диск VW: (https://yadi.sk/d/1xZ5sMZrceXWp), качаем VWFL74 и копируем с диска папку datflash и вставляем её в: C:SIDIShome

Открываем c:sidishomedbasesys2edibasbinedibas.ini (так же открыть можно блокнотом) и меняем последнюю строку:
SearchOrder=EXTERNAL-LOCAL
на
SearchOrder=LOCAL-EXTERNAL
Диск с обновлениями установлен!

Установка драйверов для устройства VAS5054A

Качаем драйвера: (https://yadi.sk/d/WVsIshTZceZHj) и запускаем файл (AutoSetup.cmd). Все драйвера автоматически установятся, во время установки несколько раз необходимо будет подтвердить действие в выпадающем окне.

Подключаем сканер с помощью USB шнура к компьютеру (к авто пока не надо), и устанавливаем драйвера для нового устройства в автоматическом режиме. Установщик запросит две установки.

Вот в принципе и вся инсталляция. Теперь можно подключиться к сети автомобиля, запустить программу и начинать работать, к примеру сделать самодиагностику! Во время открытия проги будут выпадать разные окна, что что-то там не правильно установлено и т.д., не обращайте внимание, закрывайте их работайте дальше ))).Всем удачи в установке!

Рейтинг статьи: 4

Источник

Понравилась статья? Поделить с друзьями:
  • Error number 0x8000ffff
  • Error number 0x80004005
  • Error num 80040218 kmplayer не удается найти комбинацию фильтров
  • Error no nvidia display adapters found как исправить
  • Error num 40242