I think DGroves deserves the solution kudos here, not me. His prior answer on this issue includes a link to the black plastic «diverter» that holds the 60 x 25 mm fan, and that link still works. Here is a 60 x 25 mm fan (EDIT: It actually is a 70 x 25 mm fan for the Z2 G4 SFF rear chassis fan if present) that probably would work fine:
https://www.ebay.com/itm/392575404159?hash=item5b6751487f:g:-5UAAOSwysFcIWXL
Be careful with small fans that have higher amperages… I saw some up to 3.3A which are whiner fans for servers. The one from Europe I found for 834547-001 is in the pic below (0.55A) but if you look at the fan plug end it does not look like the usual red-brown end we see in HP case fans so often… check your header on the motherboard. You’ll have to go to the original address shown in the pic to shift the pic to the plug end: The DGroves YouTube HP video link shows the usual HP case fan plug end, by the way.
EDIT: THE INFORMATION THAT THIS 60X25 REAR FAN FROM A Z240 WILL FIT APPEARS TO BE IN ERROR. ALSO THIS FAN’S PLUG END SHOWN IN THE ONLINE AD BELOW DOES NOT APPEAR TO BE A STANDARD HP CASE FAN TYPE>>> NOTE LATER IN THIS THREAD THAT THE CORRECT HP FAN FOR A Z2 G4 SFF REAR CASE FAN (IF PRESENT) HAS A DIFFERENT FOXCONN PART NUMBER AND IS ACTUALLY 70x70x25mm IN SIZE… AND ALSO HAS A TYPICAL HP CASE FAN PLUG END WITH THE USUAL RED-BROWN PLASTIC COLOR HP OFTEN USES FOR THESE.
If you go to eBay and look up pva060g12n you’ll see a fair number of those Foxconn fans… the ones with the red brown plastic plug end are easy to spot in there… from HP. Of interest sometimes HP fans will have their part number on the fan label and sometimes not. The little added alphanumerics (-P16-AB in the pic above) are unique codes for lead length and fan plug type. Fans always blow towards their round label… face it out of the case.
I recently dug up a couple of my old posts for my «Ghetto Mods» that I always did to get case fans added to the older xw generation of workstations… go to this forum’s search bar above and type in Ghetto and you’ll see those for a while now. The easy access you show to the case perforations will help you, and the size/length of screws I used were for my HP ghetto 92 x 25 mm fans so they also would work for you perfectly. I got them from Ace Hardware and used stainless. Ferrous can be nice, however, because magnetic screwdrivers can hold them nicely. Add a 60 mm fan grill to the inside face of the fan if you don’t get a HP black plastic mount cage.
In conclusion, it truly is a mystery that the motherboard would demand a fan now when it did not before. This raises a concern that it will still demand one after you feed it. I’m amazed that HP would not put a rear case fan in all of these… it is not that expensive a kit to use if they just did it for all!
Control panel message
419-Out of Memory Space for Option ROMs
41A-Front USB1/USB2 Not Connected
41B-Device in PCI Express Slot Failed To
Initialize
43A-USB Type-C I2C Not Connected
43B-More Than One USB type-C Cards Are
Installed
500–BIOS Recovery
70x-Wireless Mode Not Supported
800-Keyboard Error
801-Keyboard or System Unit Error
900-CPU Fan Not Detected
901-Chassis, Rear Chassis, or Front Chassis Fan
not Detected
903-Computer Cover Has Been Removed Since
Last System Startup
904-SATA Cabling Error
106 Chapter 7 POST error messages and diagnostic front panel LEDs and audible codes
Description
Recently added PCI expansion card contains an
option ROM too large to download during POST.
Front USB cable has been detached or unseated
from system board.
There is an incompatibility or problem with a
PCIe device and the system or PCIe link could
not be configured to a valid bus width or speed.
Cable is required between I2C on card and USB-
C on the system board.
More than one USB type-C card is installed.
A system BIOS recovery has occurred.
The system has detected a wireless module
installed in the system that is not supported
and has been disabled.
Keyboard failure.
Keyboard failure.
CPU fan is not connected or may have
malfunctioned.
Chassis, rear chassis, or front chassis fan is not
connected or may have malfunctioned.
One or more SATA devices are improperly
attached. For optimal performance, the SATA 0
and SATA 1 ports should be used for hard drives
before other ports.
Recommended action
3.
Reconfigure card resources and/or run
Computer Setup or Windows utilities.
▲
If a PCI expansion card was recently
added, remove it to see if the problem
remains.
Reconnect or replace front USB cable.
Try rebooting the system. If the error reoccurs,
the device may not work with this system
Install cable between I2C on card and USB-C on
the system board.
Remove USB type-C card so only one is
installed.
Not applicable.
Replace with a supported module.
1.
Reconnect keyboard with computer
turned off.
2.
Check connector for bent or missing pins.
3.
Ensure that none of the keys are
depressed.
4.
Replace keyboard.
1.
Reconnect the keyboard with computer
turned off.
2.
Ensure that none of the keys are
depressed.
3.
Replace the keyboard.
4.
Replace the system board.
1.
Reseat CPU fan.
2.
Reseat fan cable.
3.
Replace CPU fan.
1.
Reseat chassis, rear chassis, or front
chassis fan.
2.
Reseat fan cable.
3.
Replace chassis, rear chassis, or front
chassis fan.
N/A
Ensure SATA connectors are used in ascending
order. For one device, use SATA 0. For two
devices, use SATA 0 and SATA 1. For three
devices, use SATA 0, SATA 1, and SATA 2.
Чёрный экран с непонятной надписью вместо привычного окна Windows пугает, но проблема решается довольно просто.
Что означает ошибка CPU Fan Error
Полный текст описания такой неполадки выглядит как CPU Fan Error! Press F1 to Resume
или CPU Fan Error! Press F1 to Run SETUP
. Как можно догадаться по названию, система самодиагностики компьютера сообщает об ошибке вентилятора охлаждения процессора и предлагает продолжить или запустить настройки.
По сути, можно нажать клавишу F1 для загрузки системы и работать в обычном режиме. Но делать это стоит лишь в том случае, если уверены, что с охлаждением всё в порядке и нет риска перегрева процессора.
Из‑за чего возникает ошибка CPU Fan Error
Перед запуском и во время работы компьютера BIOS контролирует напряжение и другие параметры оборудования, включая обороты вентиляторов. Работоспособность последних определяется по их частоте вращения.
Ошибка CPU Fan Error!
появляется в тех случаях, когда система фиксирует низкие обороты вентилятора или их полное отсутствие. Без активного охлаждения процессор быстро перегреется, поэтому пользователя предупреждают об этом.
Как исправить ошибку CPU Fan Error
1. Убедитесь, что вентилятор вращается
Загляните внутрь системного блока, а лучше аккуратно снимите боковую крышку с левой стороны и проверьте вращение вентилятора процессора.
Если кулер не крутится, то ему, вероятно, что‑то мешает. Чаще всего вращение лопастей блокируют свисающие от блока питания провода или большое скопление пыли.
Решение простое и понятное: кабели подвязать с помощью пластиковых стяжек, а пыль — удалить сжатым воздухом и кисточкой. При сильных загрязнениях вентилятор, возможно, придётся снять, отвернув винты или отщёлкнув фиксаторы. Делать всё это нужно, разумеется, когда компьютер выключен.
2. Проверьте правильность подключения
Если вентилятор чист и легко крутится от руки, но при этом во время работы ПК не вращается — скорее всего, он неправильно подсоединён к разъёму на материнской плате.
На коннекторе есть специальный ключ, не дающий вставить его в предусмотренное место неправильно. И всё же по незнанию или невнимательности это можно сделать. Особенно если подключать вентилятор с тремя проводами.
Иногда пользователи путаются и подсоединяют кулер не к тому разъёму. На плате их несколько, и вентилятор процессора нужно подключить к тому, который обозначен как CPU_FAN
. Его легко спутать с находящимся неподалеку CHA_FAN
, который на самом деле предназначен для корпусного кулера.
В обоих случаях нужно лишь вставить штекер в правильный разъём и так, чтобы пазы на коннекторах совпали. При следующем включении всё заработает как надо.
3. Увеличьте обороты вентилятора
В настройках BIOS можно изменять скорость вращения кулера. И ошибка CPU Fan Error!
часто появляется, если установлены слишком низкие обороты. Система попросту считает, что вентилятор не вращается.
Если вы изменяли эти настройки, нужно отключить функцию управления оборотами Smart Q‑FAN и нажать F10 для сохранения. Еще можно подобрать частоту вращения, при которой ошибка не будет появляться. Для этого надо постепенно повышать обороты, сохранять параметры и перезагружаться для проверки.
4. Замените вентилятор
В очень редких случаях отсутствие вращения может быть вызвано поломкой самого кулера. Проверить его работоспособность можно, подав на разъём напряжение от 5 до 12 вольт. Удобнее всего использовать батарейку «Крона» или четыре последовательно соединённых элемента AA.
Для этого «минус» батарейки соединяют с контактом разъёма под номером 1 (чёрный провод), а «плюс» — с выводом номер 2 (красный или жёлтый провод). Если вентилятор не включится, придётся заменить его новым.
5. Отключите слежение за оборотами
Если кулер подсоединён к другому разъёму на материнской плате или вы намеренно снизили его обороты, чтобы добиться бесшумной работы, — можно отключить функцию контроля вращения и, соответственно, избавиться от надоедливой ошибки. Делать это стоит лишь в том случае, если вы понимаете риск перегрева или отдельно контролируете температуру с помощью дополнительного ПО вроде SpeedFan.
Для этого найдите в BIOS опцию CPU FAN Fail Warning и отключите её, установив значение Disabled или Ignored, а затем сохраните настройки и перезагрузите компьютер. В некоторых платах она может называться CPU FAN Speed или немного иначе, но примерно так же по смыслу.