One of the most popular inverter brands for solar in Australia is the Fronius Inverters range. With a range of inverters from 1.5 to 27kW there’s guaranteed to be suitable inverter for virtually any solar system size from residential to large scale industrial.
Fallon Solutions have extensive experience with solar inverters and we realise not everything is perfect all the time. Here you can find a list is a list of common Fronius inverter Error Codes with potential errors and solutions to fix them.
Fronius IG Inverter
Fronius IG STATE codes beginning with 1xx
Fronius STATE codes beginning with 1 usually only occur temporarily and are caused by the power from the electrical mains (grid) being outside the inverters operating parameters.
Code | Description | Possible causes | Remedy (sequence) |
STATE 101 | Grid voltage beyond permitted limits | 1. Mains voltage error
2. Incorrect values in the service menu 3. Internal fault |
1. Check grid voltage, check circuit breakers are ON
2. Change values in the service menu 3. If problem persists contact your Fronius Service Partner |
STATE 104 | Mains frequency beyond permitted limits. | 1. Mains frequency error
2. Incorrect values in the service menu 3. Internal fault |
1. Check mains frequency, check circuit breakers are ON
2. Change values in the service menu 3. If problem persists contact your Fronius Service Partner |
STATE 107 | Synchronisation with the public mains supply not possible | 1. Mains not connected
2. Incorrect values in the service menu 3. Internal fault |
1. Connect mains power, check circuit breakers are ON
2. Check values in the service menu 3. If problem persists contact your Fronius Service Partner |
STATE 108 | Islanding detected | 1. Islanding detected
2. Severe disturbances in public mains 3. Internal fault |
1. Automatic correction
2. Automatic correction 3. If problem persists contact your Fronius Service Partner |
Fronius IG STATE codes beginning with 2xx
Fronius IG STATE codes beginning with 2 are messages from the grid monitoring device (ENS) integrated within the inverter and refer to the parameters of the public mains.
Code | Description | Possible causes | Remedy (sequence) |
STATE 101 | Grid voltage beyond permitted limits | 1. Mains voltage error
2. Incorrect values in the service menu 3. Internal fault |
1. Check grid voltage, check circuit breakers are ON
2. Change values in the service menu 3. If problem persists contact your Fronius Service Partner |
STATE 104 | Mains frequency beyond permitted limits. | 1. Mains frequency error
2. Incorrect values in the service menu 3. Internal fault |
1. Check mains frequency, check circuit breakers are ON
2. Change values in the service menu 3. If problem persists contact your Fronius Service Partner |
STATE 107 | Synchronisation with the public mains supply not possible | 1. Mains not connected
2. Incorrect values in the service menu 3. Internal fault |
1. Connect mains power, check circuit breakers are ON
2. Check values in the service menu 3. If problem persists contact your Fronius Service Partner |
STATE 108 | Islanding detected | 1. Islanding detected
2. Severe disturbances in public mains 3. Internal fault |
1. Automatic correction
2. Automatic correction 3. If problem persists contact your Fronius Service Partner |
Fronius IG STATE codes beginning with 3xx
Fronius IG STATE codes beginning with 3 are error states that can occur during grid feed-in operation, however, they do not indicate damaged electronics and do not lead to a remaining interruption of the feed-in operation.
Code | Description | Possible causes | Remedy (sequence) |
STATE 301 | Safety circuit detects a current peak on the mains supply. | 1. Voltage drop on the public mains
2. Internal fault |
1. Automatic correction
2. If problem persists contact your Fronius Service Partner |
STATE 302 | Safety circuit detects a current peak on the PV generator side | 1. Voltage drop on the public mains supply
2. Internal fault |
1. Automatic correction
2. If problem persists contact your Fronius Service Partner |
STATE 303 | Heat sink temperature on the DC-AC board is too high | 1. Ventilation slot congested
2. Very high ambient temperature 3. Distance between inverters too small 4. Internal fault |
1. Free ventilation slot
2. Change location of inverter 3. Increase distance between inverters 4. If problem persists contact your Fronius Service Partner |
STATE 304 | Heat sink temperature on the DC-DC board is too high | ||
STATE 305 | Feed-in process not possible, even though public mains parameter within the limits | Internal fault | If problem persists contact your Fronius Service Partner |
STATE 306 | POWER LOW | Intermediate circuit voltage has dropped below permissible threshold value for feed in. | 1. Check panels
2. Internal fault |
STATE 307 | DC LOW | 1. DC-input voltage is too low for feed in
2. Internal fault |
|
STATE 308 | Intermediate circuit voltage out of the maximum limit | 1. Public mains disturbances
2. Internal fault |
1. Reinforce mains cable
2. If problem persists contact your Fronius Service Partner |
Fronius IG STATE codes beginning with 4xx
Fronius IG STATE codes beginning with 4 are error states that require the intervention of a Fronius Service Partner. They are either temporary or lasting and are triggered by faulty hardware or a software problem.
Code | Description | Possible causes | Remedy (sequence) |
STATE 401 | Communication error between IG control and the DC-DC board | Internal fault | If problem persists contact your Fronius Service Partner |
STATE 402 | Write access to the internal Fronius IG memory failed | ||
STATE 403 | The area in the internal memory for the country setting is incomplete | ||
STATE 404 | Connection between the control unit and the ENS is faulty | 1. Public mains not connected
2. Internal fault |
1. Check the public mains
2.If problem persists contact your Fronius Service Partner |
STATE 405 | An old or incorrect version of the ENS microprocessors has been recognised | Internal fault | If problem persists contact your Fronius Service Partner |
STATE 406 | Temperature sensor on the DC-AC board faulty or not connected | ||
STATE 407 | Temperature sensor on the DC-DC board faulty or not connected | ||
STATE 408 | Unsymmetry on the public mains detected | 1. Public mains disturbances
2. Internal fault |
1. Error is remedied automatically
2. If problem persists contact your Fronius Service Partner |
STATE 409 | Supply of the DC-AC board not available | Internal fault | If problem persists contact your Fronius Service Partner |
STATE 410 | Service plug on the DC-AC board is not set correctly | ||
STATE 412 | Value for fixed voltage is set higher than the open circuit voltage of the PV generator | ||
STATE 413 | Open circuit voltage too high in the moment of transformer switching | ||
STATE 414 | Memory array for Fronius IG type in EE-PROM faulty | 1. One-off – memory error
2. Internal fault |
1. Error is remedied automatically
2. If problem persists contact your Fronius Service Partner |
STATE 415 | No END-enabling signal despite release by IG-control | Internal fault | If problem persists contact your Fronius Service Partner |
STATE 416 | Communication error between IG-Control and power stack | 1. One-off – communication error
2. Internal fault |
1. Error is remedied automatically
2. If problem persists contact your Fronius Service Partner |
STATE 417 | Hardware ID-collision | Internal fault | If problem persists contact your Fronius Service Partner |
STATE 419 | Two or more power stacks with identical Unique ID | ||
STATE 420 | Incomplete number of power stacks detected after reaching online threshold according to device type | ||
STATE 421 | Hardware ID sequence error | ||
STATE 425 | Receive time-out for data exchange with one or more power stacks exceeded | 1. One off error
2. Internal fault |
1. Automatic correction
2.If problem persists contact your Fronius Service Partner |
STATE 431 | All power stacks are in boot mode | Internal fault | If problem persists contact your Fronius Service Partner |
STATE 432 | Consistent error in power stack management | 1. One off error
2. Internal fault |
1. Automatic correction
2.If problem persists contact your Fronius Service Partner |
STATE 433 | Allocation error of dynamic addresses | ||
STATE 434 | Ground fault detected | ||
STATE 435 | Wrong configuration for EE-Prom | ||
STATE 436 | Error transmission faulty | ||
STATE 437 | Power stack work around is active | ||
STATE 438 | Error during state code transmission | 1. One-off error
2. Permanent error |
1. Automatic correction
2.If problem persists contact your Fronius Service Partner |
STATE 441 | Power rack fan faulty | Internal fault | If problem persists contact your Fronius Service Partner |
STATE 442 | Master for one phase could not be assigned | 1. Temporary communication error
2. Internal fault |
1. Error is remedied automatically
2. If problem persists contact your Fronius Service Partner |
STATE 443 | DC-DC energy transfer failure. | 1. Error during switching on a power stack
2. Internal fault |
1. Error is remedied automatically
2. If problem persists contact your Fronius Service Partner |
STATE 444 | AC monitoring self test interrupted | During the self test another error occurred | Quit the self test by pressing ESC and remedy the failure according to the error code list |
Fronius IG STATE codes beginning with 5xx
Fronius IG STATE codes beginning with 5 generally do not stop the feed-in operation of the Fronius IG inverter. The STATE codes will be displayed until the message is acknowledged by pushing a button on the display (the inverter will work in feed-in operation during this time).
STATE 501 | Heat sink temperature too high, although Fronius IG is on low output | 1. Ventilation slot congested
2. Internal fault |
1. Free ventilation slot
2.If problem persists contact your Fronius Service Partner |
STATE 502 | An isolation fault between DC+ or DC- to earth has been detected | Isolation fault at the solar generator | Check cables and solar generator |
STATE 504 | An error occured while scanning LocalNet addresses | Identical Fronius IG address used twice | Check address of the inverters and other components |
STATE 505 | The area in the internal memory for the “Setup” values is incomplete | 1. One off error
2. Internal fault |
1. Automatic correction
2.If problem persists contact your Fronius Service Partner |
STATE 506 | The area in the internal memory for the “Total” values is incomplete | ||
STATE 507 | The area in the internal memory for the “Day/Year” values is incomplete | ||
STATE 508 | The area in the internal memory for the “WR number” is damaged | ||
STATE 509 | No feed in operation for 24 hours | 1. Snow covered or very dirty solar panels
2. Insufficient power from the solar panels for feed in operation 3.Internal error |
1. Clean solar panels or remove snow
2. If problem persists contact your Fronius Service Partner |
STATE 510 | Errors detected by LocalNet self diagnostic system | 1. One-off memory error
2. Internal fault |
1. Automatic correction
2. If problem persists contact your Fronius Service Partner |
STATE 511 | Errors detected by LocalNet Sensor Card self diagnostic system | ||
STATE 512 | According to the device type too many power stacks have been detected | 1. One-off error
2. Internal fault |
|
STATE 513 | Power stacks in boot mode | ||
STATE 514 | Incomplete number of power stacks detected after reaching online threshold – Device type | ||
STATE 515 | One or more power stacks notified STATE 406/ 407/ 409/ 410 | Internal fault | If problem persists contact your Fronius Service Partner |
FRONIUS GALVO COMMON ERRORS
Fronius Galvo STATE codes beginning with 1xx
Fronius STATE codes beginning with 1 usually only occur momentarily and are caused by the power from the street (the grid) being outside the inverters operating parameters.
Code | Description | Behaviour | Remedy |
STATE 102 | AC voltage too high | Following careful testing and when the grid conditions are within the permissible range again, the inverter will resume feeding energy into the grid. | Check grid connections: If this STATE code keeps recurring contact your solar power system installer. |
STATE 103 | AC voltage too low | ||
STATE 105 | AC frequency too high | ||
STATE 106 | AC frequency too low | ||
STATE 107 | AC grid outside the permissible limits | ||
STATE 108 | Stand alone operation detected |
Fronius Galvo STATE codes beginning with 3xx
Fronius Galvo STATE codes beginning with 3 are status codes that may occur while feeding energy into the grid, but generally do not cause the process to be interrupted for any length of time. The inverter disconnects automatically from the grid, the grid is then monitored as specified and the inverter attempts to resume feeding energy into the grid.
Code | Description | Behaviour | Remedy |
STATE 301 | Overcurrent (AC) | Short-term interruption while feeding energy into the grid due to over current in the inverter.
The inverter resumes with its startup routine. |
Fault is rectified automatically; if this STATE code is displayed all the time: notify your local Fronius service partner. |
STATE 302 | Safety circuit detects a current peak on the PV generator side | ||
STATE 303 | Power stage set over temperature | Short term interruption while feeding energy into the grid due to over temperature.
The inverter resumes with its startup routine. |
Purge openings for cooling air and heat sink if necessary; fault is rectified automatically; if this STATE code keeps recurring contact your solar power system installer. |
STATE 304 | Internal temperature too high | ||
STATE 306 | LOW PV OUTPUT
Intermediate circuit voltage too low for feeding energy into the grid |
Short term interruption while feeding energy into the grid.
The inverter resumes with its startup routine. |
Fault is rectified automatically; if this STATE code occurs when there is sufficient insolation (sunlight) contact your solar power system installer.
IMPORTANT! Due to the low level of insolation (sunlight) early in the morning and in the evening, the STATE codes 306 (LOW PV OUTPUT) and 307 LOW PV VOLTAGE) are displayed routinely at these times of day. These STATE codes do not indicate any kind of fault. |
STATE 307 | LOW PV VOLTAGE
DC input voltage too low for feeding energy into the grid |
||
STATE 308 | Intermediate circuit overvoltage | Short term interruption while feeding energy into the grid. The inverter resumes with its startup routine. | Fault is rectified automatically; if this STATE code is displayed all the time: notify your local Fronius service partner. |
STATE 309 | DC input voltage too high |
Fronius Galvo STATE codes beginning with 4xx
Fronius STATE codes beginning with 4 are error states that require the intervention of a Fronius Service Partner. They are either temporary or lasting and are triggered by faulty hardware or a software problem.
Code | Description | Behaviour | Remedy |
STATE 401 | No communication with power stage set possible | The inverter will automatically attempt to connect again and, if possible, will resume feeding energy into the grid. | If the STATE code is displayed all the time contact your local Fronius Service Partner |
STATE 406 | Power stage set temperature sensor faulty | ||
STATE 407 | Internal temperature sensor faulty | ||
STATE 408 | DC feeding into the grid detected | ||
STATE 412 | Fixed voltage mode has been selected instead of MPP voltage mode and the fixed voltage has been set to too low or too high a value | – | If this STATE code persists contact your solar power system installer |
STATE 415 | Safety cut out via option card or RECERBO has triggered | The inverter is not feeding any energy into the grid. | If the STATE code is displayed all the time contact your local Fronius Service Partner |
STATE 416 | No communication possible between power stage set and control system | The inverter will automatically attempt to reconnect again and, if possible, will resume feeding energy into the grid. | |
STATE 425 | No communication possible with the power stage set | ||
STATE 445 | Invalid limit value settings | The inverter is not feeding any energy into the grid for safety reasons. | Update the inverter firmware with the latest firmware here ; if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. |
STATE 452 | Communication error between the processors | The inverter will automatically attempt to connect again, and if possible, will resume feeding energy into the grid. | If the STATE code is displayed all the time: notify your local Fronius Service Partner. |
STATE 453 | Short term grid voltage error | ||
STATE 454 | Short term grid frequency error | ||
STATE 457 | Grid relay sticking | The inverter is not feeding any energy into the grid. | Contact your local Fronius Service Partner. |
STATE 459 | Error when recording the measuring signal for the insulation test | ||
STATE 460 | Reference voltage source for the digital signal processor (DSP) is working out of tolerance | ||
STATE 472 | Fuse for solar panel ground is faulty | Replace fuse for solar panel ground; if this STATE code keeps recurring contact your solar power system installer. | |
STATE 475 | Solar panel ground, insulation fault (connection between solar panel and ground) | If this STATE code keeps recurring, contact your solar power system installer | |
STATE 482 | Startup incomplete | Perform AC reset (turn AC circuit breaker off and on), complete startup. |
Fronius Galvo STATE codes beginning with 5xx
Fronius STATE codes beginning with 5 generally do not stop the feed in operation of the Fronius Galvo inverter. The STATE codes will be displayed until the message is acknowledged by pushing a button on the display (the inverter will work in feed in operation during this time).
Code | Description | Behaviour | Remedy |
STATE 502 | Insulation error on the solar panels | Warning message is shown on the display | If this STATE code keeps recurring, contact your solar power system installer. |
STATE 509 | No energy fed into the grid in the past 24 hours | It is normal to see the state 509 code when the inverter has just been installed.Acknowledge STATE code; check whether all the conditions for the problem free feeding of energy into the grid have been met. If the STATE code is displayed all the time: look out for further STATE codes. | |
STATE 516 | Firmware fault | Firmware fault with the inverter, firmware update required. | Update the inverter firmware; if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. |
STATE 517 | Derating caused by too high a temperature | When power derating occurs, a warning message is shown on the display | Purge cooling air openings and heat sink if necessary; fault is rectified automatically; if this STATE code keeps recurring contact your solar power system installer. |
STATE 551 | Fuse for solar panel ground is faulty | Warning is shown on display | Replace fuse for solar panel ground; if this STATE code keeps recurring contact your solar power system installer. |
STATE 558 | Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, e.g. after a PC board has been replaced) | Possible error displays or malfunction on the inverter | If this STATE code keeps recurring contact your solar power system installer. |
STATE 560 | Derating caused by over-frequency | This STATE code is displayed when the grid frequency becomes excessively high. The inverter will then reduce its output. The status indicator will continue to be displayed until the inverter has returned to normal operation. | As soon as the grid frequency is back within the permissible range and the inverter has returned to normal operation, the fault is rectified automatically. If this STATE code keep recurring contact your solar power system installer. |
STATE 567 | Grid Voltage Dependent Power Reduction is active | This state code is a warning informing you that the Grid Voltage Dependent Power Reduction mode (GVDPR or Volt – Watt mode) has been activated and the inverter will continue to operate with reduced power output. This is because the grid voltage has exceeded 250Vac and the GVDPR has been enabled to try to reduce the voltage rise at the inverters terminals. This mode must be enabled by default in accordance with the latest Australian Standards. | Acknowledge status code; if the STATE 567 code keeps recurring contact your local solar power system installer. |
STATE 568 | Incorrect input signal on the multifunction current interface | The STATE code is displayed in the case of an incorrect input signal on the multi-function current interface and with the following setting: Basic menu / Input signal / Mode of operation = Ext. Signal, triggering method = Warning | Acknowledge status code; check the devices connected to the multi-function current interface; if this STATE code keeps recurring contact your solar power system installer. |
Fronius Galvo STATE codes beginning with 6xx
Some of the class 6 STATE codes necessitate intervention by a Fronius Service Partner.
Code | Description | Behaviour | Remedy |
STATE 668 | Incorrect input signal on the multi-function current interface | The inverter is not feeding any energy into the grid. The STATE code is displayed in the case of an incorrect input signal at the multi-function current interface and with the following setting:
Basic menu / Input signal / Mode of operation = Ext. Signal, triggering method = Ext. Stop |
Check the devices connected to the multi-function interface; if this STATE code keeps recurring: notify your local Fronius service partner. |
Fronius Galvo STATE codes beginning with 7xx
Class 7 STATE codes on Fronius Galvo inverters relate to the control system, the configuration and inverter data recording, and may directly or indirectly affect the process of feeding energy into the grid.
Code | Description | Behaviour | Remedy |
STATE 705 | Conflict when setting the inverter number (e.g. number already assigned) | – | Correct the inverter number via the setup menu |
STATE 721 | EEPROM has been reinitialised or EEPROM is faulty | Warning message is shown on the display | Acknowledge STATE code; If the STATE code is displayed all the time contact your local Fronius Service Partner |
STATE 731 | Initialisation error – USB stick is not supported | Check or replace USB stick. Check the file system on the USB stick. If the STATE code is displayed all the time notify your local Fronius Service Partner. | |
STATE 732 | Over current on USB stick | ||
STATE 733 | No USB stick connected | Connect or check the USB stick. If STATE code is displayed all the time contact your local Fronius Service Partner. | |
STATE 734 | Update file not recognised or not present | Check update file (e.g. for correct file name). If STATE code is displayed all the time contact your local Fronius Service Partner. | |
STATE 735 | Update file does not match the device, update file too old | Warning message appears on the display, update process is interrupted. | Update the inverter firmware; if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. |
STATE 736 | Write or read error occurred | Warning message is shown on the display | Check USB stick and the data contained on it or replace USB stick.
Never unplug a USB stick if the ‘Data Transmission’ LED is still flashing or lit. If the STATE code is displayed all the contact your local Fronius Service Partner. |
STATE 738 | Log file cannot be saved (e.g. USB stick is write protected or full)t | Create storage space, remove write protection, check or replace USB stick if necessary.
If STATE code is displayed all the time contact your local Fronius Service Partner. |
|
STATE 743 | Error occurred during update process | Repeat the update process, check USB stick. If STATE code is displayed all the time contact your local Fronius Service Partner. | |
STATE 745 | Update file corrupt | Warning message appears on the display, update process is interrupted. | Re-download firmware, if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. |
STATE 751 | Time lost | Warning message is shown on the display | Reset the time and date on the inverter. Check update file (e.g. for correct file name). If STATE code is displayed all the time contact your local Fronius Service Partner. |
STATE 752 | Real Time Clock module communication error | ||
STATE 757 | Hardware error in the Real Time Clock module | Error message is shown on the display; the inverter is not feeding any energy into the grid. | If STATE code is displayed all the time contact your local Fronius Service Partner. |
STATE 758 | Internal error: Real Time Clock module is in emergency mode | Time may be inaccurate or lost (feeding energy into the grid normal).. | |
STATE 766 | Emergency power de-rating has been activated | Error message is shown on the display. |
Fronius Primo Inverter
Fronius Primo STATE codes beginning with 1xx
Fronius STATE codes beginning with 1 usually only occur momentarily and are caused by the power from the street (the grid) being outside the inverters operating parameters.
Code | Description | Behaviour | Remedy |
STATE 102 | AC voltage too high | Following careful testing and when the grid conditions are within the permissible range again, the inverter will resume feeding energy into the grid. | Check grid connections: If this STATE code keeps recurring contact your solar power system installer. |
STATE 103 | AC voltage too low | ||
STATE 105 | AC frequency too high | ||
STATE 106 | AC frequency too low | ||
STATE 107 | AC grid outside the permissible limits | ||
STATE 108 | Stand alone operation detected | ||
STATE 112 | RCMU error |
Fronius Primo STATE codes beginning with 3xx
Fronius Primo STATE codes beginning with 3 are status codes that may occur while feeding energy into the grid, but generally do not cause the process to be interrupted for any length of time.
STATE 301 | Overcurrent (AC) | Short-term interruption while feeding energy into the grid due to over current in the inverter.
The inverter resumes with its startup routine. |
Fault is rectified automatically; if this STATE code is displayed all the time: notify your local Fronius service partner. |
STATE 302 | Overcurrent (DC) | ||
STATE 303 | Power stage set over temperature | Short term interruption while feeding energy into the grid due to over temperature.
The inverter resumes with its startup routine. |
Purge openings for cooling air and heat sink if necessary; fault is rectified automatically; if this STATE code keeps recurring contact your solar power system installer. |
STATE 304 | Internal temperature too high | ||
STATE 306 | LOW PV OUTPUT
Intermediate circuit voltage too low for feeding energy into the grid |
Short term interruption while feeding energy into the grid.
The inverter resumes with its startup routine. |
Fault is rectified automatically; if this STATE code occurs when there is sufficient insolation (sunlight) contact your solar power system installer.
IMPORTANT! Due to the low level of insolation (sunlight) early in the morning and in the evening, the STATE codes 306 (LOW PV OUTPUT) and 307 LOW PV VOLTAGE) are displayed routinely at these times of day. These STATE codes do not indicate any kind of fault. |
STATE 307 | LOW PV VOLTAGE
DC input voltage too low for feeding energy into the grid |
||
STATE 308 | Intermediate circuit overvoltage | Short term interruption while feeding energy into the grid. The inverter resumes with its startup routine. | Fault is rectified automatically; if this STATE code is displayed all the time: notify your local Fronius service partner. |
STATE 309 | DC input voltage MPPT 1 too high | ||
STATE 313 | DC input voltage MPPT 2 too high |
Fronius Primo STATE codes beginning with 4xx
Fronius STATE codes beginning with 4 are error states that require the intervention of a Fronius Service Partner. They are either temporary or lasting and are triggered by faulty hardware or a software problem. Try switching off the Fronius inverter following the system shutdown procedure, leave off for a few minutes then attempt to restart. If the fault continues please contact your local Fronius Service Partner for further assistance.
Code | Description | Behaviour | Remedy |
STATE 401 | No communication with power stage set possible | The inverter will automatically attempt to connect again and, if possible, will resume feeding energy into the grid. | If the STATE code is displayed all the time contact your local Fronius Service Partner |
STATE 406 | Power stage set temperature sensor faulty | ||
STATE 407 | Internal temperature sensor faulty | ||
STATE 408 | DC feeding into the grid detected | ||
STATE 412 | Fixed voltage mode has been selected instead of MPP voltage mode and the fixed voltage has been set to too low or too high a value | – | If this STATE code persists contact your solar power system installer |
STATE 415 | Safety cut out via option card or RECERBO has triggered | The inverter is not feeding any energy into the grid. | If the STATE code is displayed all the time contact your local Fronius Service Partner |
STATE 416 | No communication possible between power stage set and control system | The inverter will automatically attempt to reconnect again and, if possible, will resume feeding energy into the grid. | |
STATE 417 | Hardware ID problem | ||
STATE 419 | Unique ID conflict | ||
STATE 421 | HID range error | ||
STATE 425 | No communication possible with the power stage set | ||
STATE 426-428 | Possible hardware fault | ||
STATE 431 | Software problem | The inverter is not feeding any energy into the grid. | Carry out an AC reset (switch the AC circuit breaker off and on); update the firmware; if this status code is displayed all the time please contact your local Fronius Service Partner. |
STATE 436 | Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, e.g. after a PC board has been replaced. | The inverter will automatically attempt to connect again and, if possible, will resume feeding energy into the grid. | Update the inverter firm ware; if this status code is displayed all the time please contact your local Fronius Service Partner. |
STATE 437 | Power stage set problem | ||
STATE 438 | Functional incompatibility (one or more PC boards in the inverter in the inverter are not compatible with each other, e.g. after a PC board has been replaced) | ||
STATE 443 | Intermediate circuit voltage too low or asymmetric | The inverter is not feeding any energy into the grid. | If the status code is displayed all the time contact your local Fronius Service Partners. |
STATE 445 | Invalid limit value settings | The inverter is not feeding any energy into the grid for safety reasons. | Update the inverter firmware; if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. |
STATE 447 | Insulation fault | If this status code is displayed all the time: notify a local Fronius Service Partner | |
STATE 448 | Neutral conductor not connected | ||
STATE 450 | Guard cannot be found | ||
STATE 452 | Memory error detected | The inverter will automatically attempt to connect again, and if possible, will resume feeding energy into the grid. | If the STATE code is displayed all the time: notify your local Fronius Service Partner. |
STATE 452 | Communication error between the processors | ||
STATE 453 | Short term grid voltage error | ||
STATE 454 | Short term grid frequency error | ||
STATE 456 | Anti-islanding function is no longer implemented correctly | ||
STATE 457 | Grid relay sticking | The inverter is not feeding any energy into the grid. | Contact your local Fronius Service Partner. |
STATE 459 | Error when recording the measuring signal for the insulation test | ||
STATE 460 | Reference voltage source for the digital signal processor (DSP) is working out of tolerance | ||
STATE 461 | Fault in the DSP data memory | ||
STATE 462 | Error with DC feed monitoring routine | ||
STATE 463 | Reversed AC polarity, AC connector inserted incorrectly | ||
STATE 474 | RCMU sensor faulty | If this STATE code keeps recurring, contact your solar power system installer | |
STATE 475 | Solar panel ground fault, insulation fault (connection between solar panel and ground) | ||
STATE 476 | Driver supply voltage too low | ||
STATE 480, 481 | Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, e.g. after a PC board has been replaced) | Update the inverter firmware; if the STATE code persists contact your local Fronius Service Partner | |
STATE 482 | Startup incomplete | Perform AC reset (turn AC circuit breaker off and on), complete startup. | |
STATE 483 | Voltage UDC fixed on MPP2 string out of limits | Check the MPP settings; if the status code is displayed all the time contact your local Fronius Service Partner | |
STATE 485 | CAN transmit buffer is full | Carry out an AC reset (turn AC circuit breaker off and on), if the STATE code continues to be displayed notify your local Fronius Service Partner. |
Fronius Primo STATE codes beginning with 5xx
Fronius STATE codes beginning with 5 generally do not stop the feed in operation of the Fronius Primo inverter. The STATE codes will be displayed until the message is acknowledged by pushing a button on the display (the inverter will work in feed in operation during this time).
Code | Description | Behaviour | Remedy |
STATE 502 | Insulation error on the solar panels | Warning message is shown on the display | If this STATE code keeps recurring, contact your solar power system installer. |
STATE 509 | No energy fed into the grid in the past 24 hours | Acknowledge STATE code; check whether all the conditions for the problem free feeding of energy into the grid have been met. If the STATE code is displayed all the time: look out for further STATE codes. | |
STATE 515 | No communication with filter possible | If the status code is displayed all the time notify your local Fronius Service Partner. | |
STATE 516 | No communication possible with the storage unit | Storage unit warning message. | |
STATE 517 | Derating caused by too high a temperature | When power derating occurs, a warning message is shown on the display | Purge cooling air openings and heat sink if necessary; fault is rectified automatically; if this STATE code keeps recurring contact your solar power system installer. |
STATE 522 | DC1 Input Voltage too low | The DC voltage on input 1 of the inverter is too low | Check voltage & polarity on input 1 of the inverter. If this STATE code keeps recurring please contact your solar power system installer. |
STATE 523 | DC2 Input Voltage too low | The DC voltage on input 2 of the inverter is too low | Check voltage & polarity on input 2 of the inverter. Check MPP settings / voltage at the “Installer Menu Basic”. If this STATE code keeps recurring please contact your solar power system installer. |
STATE 558 | Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, e.g. after a PC board has been replaced) | Possible error displays or malfunction on the inverter | If this STATE code keeps recurring contact your solar power system installer. |
STATE 560 | Derating caused by over-frequency | This STATE code is displayed when the grid frequency becomes excessively high. The inverter will then reduce its output. The status indicator will continue to be displayed until the inverter has returned to normal operation. | As soon as the grid frequency is back within the permissible range and the inverter has returned to normal operation, the fault is rectified automatically. If this STATE code keep recurring contact your solar power system installer. |
STATE 566 | Arc detector switched off (e.g. during external arc monitoring) | The STATE code is displayed every day until the arc detector is reactivated. | No error, Confirm status code by pressing ‘Enter’. |
STATE 567 | Grid Voltage Dependent Power Reduction is active | This state code is a warning informing you that the Grid Voltage Dependent Power Reduction mode (GVDPR or Volt – Watt mode) has been activated and the inverter will continue to operate with reduced power output. This is because the grid voltage has exceeded 250Vac and the GVDPR has been enabled to try to reduce the voltage rise at the inverters terminals. This mode must be enabled by default in accordance with the latest Australian Standards. | Acknowledge status code; if this STATE 567 code keeps recurring contact your local solar power system installer. |
Fronius Primo STATE codes beginning with 7xx
Class 7 STATE codes on Fronius Primo inverters relate to the control system, the configuration and inverter data recording, and may directly or indirectly affect the process of feeding energy into the grid.
Code | Description | Behaviour | Remedy |
STATE 705 | Conflict when setting the inverter number (e.g. number already assigned) | – | Correct the inverter number via the setup menu |
STATE 721 | EEPROM has been reinitialised or EEPROM is faulty | Warning message is shown on the display | Acknowledge STATE code; If the STATE code is displayed all the time contact your local Fronius Service Partner |
STATE 731 | Initialisation error – USB stick is not supported | Check or replace USB stick. Check the file system on the USB stick. If the STATE code is displayed all the time notify your local Fronius Service Partner. | |
STATE 732 | Over current on USB stick | ||
STATE 733 | No USB stick connected | Connect or check the USB stick. If STATE code is displayed all the time contact your local Fronius Service Partner. | |
STATE 734 | Update file not recognised or not present | Check update file (e.g. for correct file name). If STATE code is displayed all the time contact your local Fronius Service Partner. | |
STATE 735 | Update file does not match the device, update file too old | Warning message appears on the display, update process is interrupted. | Update the inverter firmware; if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. If STATE code is displayed all the time contact your local Fronius Service Partner. |
STATE 736 | Write or read error occurred | Warning message is shown on the display | Check USB stick and the data contained on it or replace USB stick.
Never unplug a USB stick if the ‘Data Transmission’ LED is still flashing or lit. If the STATE code is displayed all the contact your local Fronius Service Partner. |
STATE 738 | Log file cannot be saved (e.g. USB stick is write protected or full)t | Create storage space, remove write protection, check or replace USB stick if necessary.
If STATE code is displayed all the time contact your local Fronius Service Partner. |
|
STATE 743 | Error occurred during update process | Repeat the update process, check USB stick. If STATE code is displayed all the time contact your local Fronius Service Partner. | |
STATE 745 | Update file corrupt | Warning message appears on the display, update process is interrupted. | Redownload the firmware. If STATE code is displayed all the time contact your local Fronius Service Partner. |
STATE 751 | Time lost | Warning message is shown on the display | Reset the time and date on the inverter. Check update file (e.g. for correct file name). If STATE code is displayed all the time contact your local Fronius Service Partner. |
STATE 752 | Real Time Clock module communication error | ||
STATE 757 | Hardware error in the Real Time Clock module | Error message is shown on the display; the inverter is not feeding any energy into the grid. | If STATE code is displayed all the time contact your local Fronius Service Partner. |
STATE 758 | Internal error: Real Time Clock module is in emergency mode | Time may be inaccurate or lost (feeding energy into the grid normal).. | |
STATE 766 | Emergency power de-rating has been activated | Error message is shown on the display. |
Fronius Symo
Fronius SYMO STATE codes beginning with 1xx
Fronius STATE codes beginning with 1 usually only occur momentarily and are caused by the power from the street (the grid) being outside the inverters operating parameters. The Fronius inverter reacts by disconnecting from the grid and attempts to switch on again after the specified mains monitoring period, if no further errors occur during this period. The STATE code is displayed whilst the grid is being checked.
Code | Description | Behaviour | Remedy |
STATE 102 | AC voltage too high | Following careful testing and when the grid conditions are within the permissible range again, the inverter will resume feeding energy into the grid. | Check grid connections: If this STATE code keeps recurring contact your solar power system installer. |
STATE 103 | AC voltage too low | ||
STATE 105 | AC frequency too high | ||
STATE 106 | AC frequency too low | ||
STATE 107 | AC grid outside the permissible limits | ||
STATE 108 | Stand alone operation detected | ||
STATE 112 | RCMU error |
Fronius SYMO STATE codes beginning with 3xx
Fronius SYMO STATE codes beginning with 3 are status codes that may occur while feeding energy into the grid, but generally do not cause the process to be interrupted for any length of time. The inverter disconnects automatically from the grid, the grid is then monitored as specified and the inverter attempts to resume feeding energy into the grid.
Code | Description | Behaviour | Remedy |
STATE 301 | Overcurrent (AC) | Short-term interruption while feeding energy into the grid due to over current in the inverter.
The inverter resumes with its startup routine. |
Fault is rectified automatically; if this STATE code is displayed all the time: notify your local Fronius service partner. |
STATE 302 | Overcurrent (DC) | ||
STATE 303 | DC module over temperature | Short term interruption while feeding energy into the grid due to over temperature.
The inverter resumes with its startup routine. |
Purge openings for cooling air and heat sink if necessary; fault is rectified automatically; if this STATE code keeps recurring contact your solar power system installer. |
STATE 304 | AC module over temperature | ||
STATE 305 | No power being fed in, despite closed relay | Short term interruption while feeding energy into the grid due to over temperature.
The inverter resumes with its startup routine. |
fault is rectified automatically; if this STATE code keeps recurring contact your solar power system installer. |
STATE 306 | PV output too low for feeding energy into the grid | Short term interruption while feeding energy into the grid.
The inverter resumes with its startup routine. |
Fault is rectified automatically; if this STATE code occurs when there is sufficient insolation (sunlight) contact your solar power system installer.
IMPORTANT! Due to the low level of insolation (sunlight) early in the morning and in the evening, the STATE codes 306 (LOW PV OUTPUT) and 307 LOW PV VOLTAGE) are displayed routinely at these times of day. These STATE codes do not indicate any kind of fault. |
STATE 307 | LOW PV VOLTAGE
DC input voltage too low for feeding energy into the grid |
||
STATE 308 | Intermediate circuit voltage too high | Short term interruption while feeding energy into the grid. The inverter resumes with its startup routine. | Fault is rectified automatically; if this STATE code is displayed all the time: notify your local Fronius service partner. |
STATE 309 | DC input voltage MPPT 1 too high | ||
STATE 311 | Polarity of DC strings reversed | ||
STATE 313 | DC input voltage MPPT 2 too high | ||
STATE 314 | Current sensor calibration timeout | Short term interruption while feeding energy into the grid. The inverter resumes with its startup routine. | Fault is rectified automatically; if this STATE code is displayed all the time: notify your local Fronius service partner. |
STATE 315 | AC current sensor erro | ||
STATE 316 | Interrupt Check fail | ||
STATE 325 | Overtemperature in the connection area | ||
STATE 326 | Fan 1 error | ||
STATE 327 | Fan 2 error |
Fronius SYMO STATE codes beginning with 4xx
Fronius STATE codes beginning with 4 are error states that require the intervention of a Fronius Service Partner. They are either temporary or lasting and are triggered by faulty hardware or a software problem. Try switching off the Fronius inverter following the system shutdown procedure, leave off for a few minutes then attempt to restart.
Code | Description | Behaviour | Remedy |
STATE 401 | No communication possible with the power stage set | The inverter will automatically attempt to connect again and, if possible, will resume feeding energy into the grid. | If the STATE code is displayed all the time contact your local Fronius Service Partner |
STATE 406 | AC module temperature sensor faulty (L1) | ||
STATE 407 | AC module temperature sensor faulty (L2) | ||
STATE 408 | DC component measured in the grid too high | ||
STATE 412 | Fixed voltage mode has been selected instead of MPP voltage mode and the fixed voltage has been set to too low or too high a value | – | If this STATE code persists contact your solar power system installer |
STATE 415 | Safety cut out via option card or RECERBO has triggered | The inverter is not feeding any energy into the grid. | If the STATE code is displayed all the time contact your local Fronius Service Partner |
STATE 416 | No communication possible between power stage set and control system | The inverter will automatically attempt to reconnect again and, if possible, will resume feeding energy into the grid. | |
STATE 417 | Hardware ID problem | Update the inverter firmware; if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. | |
STATE 419 | Unique ID conflict | ||
STATE 420 | No communication possible with the Hybrid manager | ||
STATE 421 | HID range error | ||
STATE 425 | No communication with the power stage set possible | ||
STATE 426-428 | Possible hardware fault | ||
STATE 431 | Software problem | The inverter is not feeding any energy into the grid. | Carry out an AC reset (switch the AC circuit breaker off and on); update inverter firmware; if this status code is displayed all the time please contact your local Fronius Service Partner. |
STATE 436 | Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, e.g. after a PC board has been replaced. | The inverter will automatically attempt to connect again and, if possible, will resume feeding energy into the grid. | Update the inverter firmware; if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. |
STATE 437 | Power stage set problem | ||
STATE 438 | Functional incompatibility (one or more PC boards in the inverter in the inverter are not compatible with each other, e.g. after a PC board has been replaced) | ||
STATE 443 | Intermediate circuit voltage too low or asymmetric | The inverter is not feeding any energy into the grid. | If the status code is displayed all the time contact your local Fronius Service Partners. |
STATE 445 | – Compatability error (e.g. due to replacement of a PC board)
– invalid power stage set configuration |
The inverter is not feeding any energy into the grid for safety reasons. | Update the inverter firmware; if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. |
STATE 447 | Insulation fault | If this status code is displayed all the time: notify a local Fronius Service Partner | |
STATE 448 | Neutral conductor not connected | ||
STATE 450 | Guard cannot be found | ||
STATE 451 | Memory error detected | The inverter will automatically attempt to connect again, and if possible, will resume feeding energy into the grid. | If the STATE code is displayed all the time: notify your local Fronius Service Partner. |
STATE 452 | Communication error between the processors | ||
STATE 453 | Grid voltage and power stage set are incompatible | ||
STATE 454 | Grid frequency and power stage set are incompatible | ||
STATE 456 | Anti-islanding function is no longer implemented correctly | ||
STATE 457 | Grid relay sticking or the neutral conductor ground voltage is too high | The inverter is not feeding any energy into the grid. | Check the grounding (the neutral conductor ground voltage must be less than 30V. If problem persists contact your local Fronius Service Partner. |
STATE 458 | Error when recording the measuring signal | Contact your local Fronius Service Partner. | |
STATE 459 | Error when recording the measuring signal for the insulation test | ||
STATE 460 | Reference voltage source for the digital signal processor (DSP) is working out of tolerance | ||
STATE 461 | Fault in the DSP data memory | ||
STATE 462 | Error with DC feed monitoring routine | ||
STATE 463 | Reversed AC polarity, AC connector inserted incorrectly | ||
STATE 474 | RCMU sensor faulty | ||
STATE 475 | Solar panel ground fault, insulation fault (connection between solar panel and ground) | ||
STATE 476 | Driver supply voltage too low | ||
STATE 480, 481 | Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, e.g. after a PC board has been replaced) | Update the inverter firmware; if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. | |
STATE 482 | Setup after the initial start-up was interrupted | Perform AC reset (turn AC circuit breaker off and on), complete startup. | |
STATE 483 | Voltage UDC fixed on MPP2 string out of limits | Check the MPP settings; if the status code is displayed all the time contact your local Fronius Service Partner | |
STATE 485 | CAN transmit buffer is full | Carry out an AC reset (turn AC circuit breaker off and on), if the STATE code continues to be displayed notify your local Fronius Service Partner. |
Fronius SYMO STATE codes beginning with 5xx
Fronius STATE codes beginning with 5 generally do not stop the feed in operation of the Fronius SYMO inverter. The STATE codes will be displayed until the message is acknowledged by pushing a button on the display (the inverter will work in feed in operation during this time).
Code | Description | Behaviour | Remedy |
STATE 502 | Insulation error on the solar panels | Warning message is shown on the display | If this STATE code keeps recurring, contact your solar power system installer. |
STATE 509 | No energy fed into the grid in the past 24 hours | Acknowledge STATE code; check whether all the conditions for the problem free feeding of energy into the grid have been met. If the STATE code is displayed all the time: look out for further STATE codes. | |
STATE 515 | No communication with filter possible | If the status code is displayed all the time notify your local Fronius Service Partner. | |
STATE 516 | No communication possible with the storage unit | Storage unit warning message. | |
STATE 517 | Power derating caused by too high a temperature | When power derating occurs, a warning message is shown on the display | Purge cooling air openings and heat sink if necessary; fault is rectified automatically; if this STATE code keeps recurring contact your solar power system installer. |
STATE 518 | Internal DSP malfunction | Warning message on the display | If this STATE code keeps recurring contact your solar power system installer. |
STATE 519 | No communication possible with the storage unit | Storage unit warning message | |
STATE 520 | No energy fed into the grid by MPPT1 in the past 24 hours | Warning message is shown on the display | Acknowledge status code; check whether all the conditions for the problem free feeding of energy into the grid has been met. If this STATE code keeps recurring contact your solar power system installer. |
STATE 522 | DC low string 1 | Warning message on the display | |
STATE 523 | DC low string 2 | ||
STATE 558, 559 | Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, e.g. after a PC board has been replaced) | Update the inverter firmware;if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. | |
STATE 560 | Derating caused by over-frequency | This STATE code is displayed when the grid frequency becomes excessively high. The inverter will then reduce its output. The status indicator will continue to be displayed until the inverter has returned to normal operation. | As soon as the grid frequency is back within the permissible range and the inverter has returned to normal operation, the fault is rectified automatically. If this STATE code keep recurring contact your solar power system installer. |
STATE 564 | Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, e.g. after a PC board has been replaced) | Warning message on the display | Update the inverter firmware if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. |
STATE 566 | Arc detector switched off (e.g. during external arc monitoring) | The STATE code is displayed every day until the arc detector is reactivated. | No error
Confirm status code by pressing ‘Enter’. |
STATE 567 | Grid Voltage Dependent Power Reduction is active | This state code is a warning informing you that the Grid Voltage Dependent Power Reduction mode (GVDPR or Volt – Watt mode) has been activated and the inverter will continue to operate with reduced power output. This is because the grid voltage has exceeded 250Vac and the GVDPR has been enabled to try to reduce the voltage rise at the inverters terminals. This mode must be enabled by default in accordance with the latest Australian Standards. | Acknowledge status code; if this STATE 567 code keeps recurring contact your local solar power system installer. |
Fronius SYMO STATE codes beginning with 6xx
Class 6 STATE codes on Fronius SYMO inverters necessitate intervention by a Fronius trained service engineer.
Code | Description | Behaviour | Remedy |
STATE 601 | CAN bus is full | The inverter is not feeding any energy into the grid. | Update the inverter firmware; if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. |
STATE 603 | AC module temperature sensor faulty (L3) | The inverter will automatically attempt to connect again and, if possible, will resume feeding energy into the grid. | If this STATE code keeps recurring contact your solar power system installer. |
STATE 604 | DC module temperature sensor faulty | ||
STATE 607 | RCMU error | The inverter is not feeding any energy into the grid. | Reset status code by pressing ‘Enter’. The inverter resumes the feeding of energy into the grid; if the status code keeps appearing, check the complete solar system for damage. |
STATE 608 | Functional incompatibility (one or more PC boards in the inverter are not compatible with each other, e.g. after a PC board has been replaced) | Update the inverter firmware; if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. |
Fronius SYMO STATE codes beginning with 7xx
Class 7 STATE codes on Fronius SYMO inverters relate to the control system, the configuration and inverter data recording, and may directly or indirectly affect the process of feeding energy into the grid.
Code | Description | Behaviour | Remedy |
STATE 701-716 | Provides information about the internal processor status | Warning message is shown on the display | If the STATE code is displayed all the time notify your local Fronius Service Partner. |
STATE 721 | EEPROM has been re-initialised | Acknowledge STATE code; If the STATE code is displayed all the time contact your local Fronius Service Partner | |
STATE 722-730 | Provides information about the internal processor status | If the STATE code is displayed all the time contact your local Fronius Service Partner | |
STATE 731 | Initialisation error – USB flash drive is not supported | Check or replace USB flash drive. Check the file system on the USB flash drive. If the STATE code is displayed all the time notify your local Fronius Service Partner. | |
STATE 732 | Initialisation erro – Over current on USB stick | ||
STATE 733 | No USB flash drive connected | Connect or check the USB flash drive. If STATE code is displayed all the time contact your local Fronius Service Partner. | |
STATE 734 | Update file not recognised or not present | Check update file (e.g. for correct file name). If STATE code is displayed all the time contact your local Fronius Service Partner. | |
STATE 735 | Update file does not match the device, update file too old | Warning message appears on the display, update process is interrupted. | Check the update file; if the STATE code is displayed all the time after the firmware update contact your local Fronius Service Partner. |
STATE 736 | Write or read error occurred | Warning message is shown on the display | Check USB flash drive and the data contained on it or replace USB flash drive.
Never unplug a USB flash drive if the ‘Data Transmission’ LED is still flashing or lit. If the STATE code is displayed all the time contact your local Fronius Service Partner. |
STATE 737 | File could not be opened | Remove and then reinsert USB flash drive; check or replace USB flash drive | |
STATE 738 | Log file cannot be saved (e.g. USB flash drive is write protected or full) | Create storage space, remove write protection, check or replace USB stick if necessary.
If STATE code is displayed all the time contact your local Fronius Service Partner. |
|
STATE 740 | Initialisation error-error in file system on USB flash drive | Check USB flash drive; reformat on PC for FAT12, FAT16 or FAT32. | |
STATE 741 | Error during recording of logging data | Remove and then reinsert USB flash drive; check or replace USB flash drive | |
STATE 743 | Error occurred during update process | Repeat the update process, check USB stick. If STATE code is displayed all the time contact your local Fronius Service Partner. | |
STATE 745 | Update file corrupt | Warning message appears on the display, update process is interrupted. | Re-download update file. If STATE code is displayed all the time contact your local Fronius Service Partner. |
STATE 746 | Error occurred during update process | Wait for 2 minutes, then start the update again. If STATE code is displayed all the time contact your local Fronius Service Partner. | |
STATE 751 | Time lost | Warning message is shown on the display | Reset the time and date on the inverter. Check update file (e.g. for correct file name). If STATE code is displayed all the time contact your local Fronius Service Partner. |
STATE 752 | Real Time Clock module communication error | ||
STATE 753 | Internal error: Real Time Clock module is in emergency mode | Time may be inaccurate or lost (feeding energy into the grid normal) | |
STATE 754-755 | Provides information about the processor status | Warning message on the display | If STATE code is displayed all the time contact your local Fronius Service Partner. |
STATE 757 | Hardware error in the Real Time Clock module | Error message is shown on the display; the inverter is not feeding any energy into the grid. | |
STATE 758 | Internal error: Real Time Clock module is in emergency mode | Time may be inaccurate or lost (feeding energy into the grid normal). | Reset time and date on the inverter |
STATE 760 | Internal hardware error | Error message is shown on the display. | If STATE code is displayed all the time contact your local Fronius Service Partner. |
STATE 761-765 | Provides information about the internal processor status | Warning message is shown on the display. | |
STATE 766 | Emergency power de-rating has been activated | Error message is shown on the display. | |
STATE 767 | Provides information about the internal processor status | Warning message is shown on the display. | |
STATE 768 | Different power limitation in the hardware modules | ||
STATE 772 | Storage unit not available | ||
STATE 773 | Software update group 0 (invalid country setup) | ||
STATE 775 | PMC power stage set not available | Warning message is shown on the display. | Press ‘Enter’ key to acknowledge error. If STATE code is displayed all the time contact your local Fronius Service Partner. |
STATE 776 | Invalid device type | ||
STATE 781-794 | Provides information about the internal processor status | Warning message is shown on the display. | If STATE code is displayed all the time contact your local Fronius Service Partner. |
Fallon Solutions can take care of all your Fronius solar Inverter issues and offer upgrades to your solar installation or we can offer a 26 point safety check of your existing system. Simply call us on 1300 762 260 or fill in an online solar inverter enquiry form and one of our friendly team will contact you.
Рекомендуемые сообщения
-
#1
где найти таблицу кодов ошибок для фрониус ВариоСинержик 5000 и если кто знает какие основные болячки у этого аппарата бывают
Поделиться сообщением
Ссылка на сообщение
-
#2
Что интересует конкретно?? Какие то проблемы??
Поделиться сообщением
Ссылка на сообщение
-
#3
проблема в следуюшем на работе стоит трактор фрониус документов к нему нет вообще переодичеки выдаёт ошибку е42 приходится всё исправлять методом тыка что очень неудобно, хотелось бы найти документы к нему и ели кто сталкивался с таким аппаратом что у него чаще бывают за проблемы т.е. куда сразу стоит обратить внимание.
Поделиться сообщением
Ссылка на сообщение
-
#4
E42 КЗ во вторичных цепях, возможные проблемы горелка или силовые провода.
Изменено 04.03.2012 10:16 пользователем s_even
Поделиться сообщением
Ссылка на сообщение
-
#5
Поделиться сообщением
Ссылка на сообщение
-
#6
Добрый день! Аппарат фрониус 320ТСР, постоянно выдает ошибку 9649, варим АМг5
Поделиться сообщением
Ссылка на сообщение
Для публикации сообщений создайте учётную запись или авторизуйтесь
Вы должны быть пользователем, чтобы оставить комментарий
Войти
Уже есть аккаунт? Войти в систему.
Войти
-
Последние посетители
0 пользователей онлайн
Ни одного зарегистрированного пользователя не просматривает данную страницу
07:37
Fronius Acctiva Professional 35A
04:19
Fronius: Battery Charging System Acctiva Professional Flash during diagnosis and software updates
04:19
Acctiva Professional Flash EN.wmv
04:19
Fronius: Batterieladesystem Acctiva Professional Flash bei Diagnose & Software-Updates
06:28
Prostownik Fronius Acctiva Professional Flash 70A — prezentacja
00:33
Fronius Acctiva Professional prezentacja produktu
01:29
Como configurar Fronius Selectiva 3 kW
00:51
fronius korea distributor’s initial setting of acctiva professional flash 70A
79
RU
Диагностика и устранение ошибок
Поиск и
устранение
неисправностей
Зарядные клеммы подсоединены к неправильным полюсам
Причина
Зарядные клеммы подсоединены к неправильным полюсам
Решение
Поменяйте местами зарядные клеммы
Короткое замыкание зарядных клемм
Причина
Короткое замыкание зарядных клемм
Решение
Устраните короткое замыкание зарядных клемм
Причина
Не обнаружена аккумуляторная батарея
Решение
Убедитесь, что зарядные клеммы правильно
подсоединены, нажмите кнопку «Старт/стоп» и
удерживайте ее 5 секунд
Перегрев
Причина
Перегрев — зарядное устройство слишком горячее
Решение
Дайте зарядному устройству охладиться
Причина
Перекрыты отверстия для притока и оттока воздуха
Решение
Устраните перекрытие отверстий для притока и оттока
воздуха
Защитное отключение
Причина
Неисправность аккумуляторной батареи
Решение
Проверьте аккумуляторную батарею
Причина
Неправильная настройка зарядного устройства
Решение
Проверьте настройки: A•ч, напряжение
Причина
Неправильный тип аккумуляторной батареи (например,
NiCd), неправильное количество элементов (напряжение)
Решение
Проверьте тип аккумуляторной батареи
80
Вентилятор заблокирован/неисправен
Причина
Вентилятор заблокирован
Решение
Проверьте отверстие для притока воздуха, при
необходимости удалите посторонние тела
Причина
Вентилятор неисправен
Решение
Обратитесь к первичному дилеру
Неисправность плавкого предохранителя
Причина
Неисправность предохранителя на вторичной стороне
Решение
Обратитесь к первичному дилеру
Неисправность зарядного устройства
Причина
Неисправность зарядного устройства
Решение
Обратитесь к первичному дилеру
Нет индикации на дисплее
Причина
Прерывание подачи питания
Решение
Подсоедините источник питания
Причина
Неисправность сетевого штекера или сетевого кабеля
Решение
Замените сетевой штекер или сетевой кабель
Причина
Неисправность зарядного устройства
Решение
Обратитесь к первичному дилеру
Зарядное устройство не начинает зарядку
Причина
Неисправны зарядные клеммы или провод зарядного
устройство
Решение
Замените зарядные клеммы или провод зарядного
устройства
(момент затяжки гайки M8 = 15 Н•м)
81
RU
Используемые символы
Предупреждающ
ие знаки на
зарядном
устройстве
Соблюдайте инструкции, изложенные в руководстве по эксплуатации
Правильно подсоединяйте полюса аккумуляторной батареи:
(+) красный (-) черный
В процессе зарядки в аккумуляторе образуется детонирующий газ.
Существует опасность взрыва!
Зарядное устройство нагревается в зависимости от условий
эксплуатации.
Прежде чем отсоединить провод зарядного устройства от аккумуляторной
батареи, прервите процесс зарядки.
Открывать зарядные устройства может только квалифицированный
электрик.
Избегайте открытого огня и искр во время зарядки.
Обеспечьте надлежащую вентиляцию в процессе зарядки.
В аккумуляторной батарее используется коррозионная кислота.
Только для внутреннего использования.
Исключите возможность попадания на устройство дождевых капель.
82
Технические характеристики
Acctiva
Professional
Flash,
Acctiva
Professional
Flash AUS,
Acctiva
Professional
Flash JP,
Acctiva
Professional 30A
JP
*
При повышении температуры окружающей среды выше 35 °C (95 °F) или
около того (в зависимости от напряжения вторичного контура) ток вторичного
контура уменьшается (снижение номинальной мощности).
Напряжение сети (+/- 15 %)
Acctiva Professional Flash
Acctiva Professional Flash AUS
Acctiva Professional Flash JP
Acctiva Professional 30A JP
230 В пер. тока, 50/60 Гц
240 В пер. тока, 50/60 Гц
100 В пер. тока, 50/60 Гц
100 В пер тока, 50/60 Гц
Макс. номинальная
производительность
Acctiva Professional Flash
Acctiva Professional Flash AUS
Acctiva Professional Flash JP
Acctiva Professional 30A JP
1080 Вт
1080 Вт
1080 Вт
710 Вт
Зарядное напряжение
12,0 – 15,5 В
Ток зарядки I
2
(регулируемый)
Acctiva Professional Flash
Acctiva Professional Flash AUS
Acctiva Professional Flash JP
Acctiva Professional 30A JP
2 — 50 A
2 — 50 A
2 — 50 A
2 — 30 A
Ток зарядки в повышающем режиме
t
2 max
(tI
2 max
= 30 с, tI
2
= 60 с)
Acctiva Professional Flash
Acctiva Professional Flash AUS
Acctiva Professional Flash JP
Acctiva Professional 30A JP
макс. 70 A
макс. 70 A
макс. 70 A
макс. 30 A
Номинальная емкость зарядки
10 – 250/300 А•ч
Количество элементов:
6
Графическая характеристика заряда
IUoU/IUa/IU
Рабочая температура *
от 0 до +60 °C
от 32 °F до 140 °F
Температура хранения
от -20 °C до +80 °C
от 4 °F до 176 °F
Интерфейс
USB
Климатический класс (EN50178)
B
Класс ЭМС
Acctiva Professional Flash
Acctiva Professional Flash AUS
Acctiva Professional Flash JP
Acctiva Professional 30A JP
IEC/EN 61000-6-4/2 (класс ЭМСA)
IEC/EN 61000-6-4/2 (класс ЭMC A)
IEC/EN 61000-6-4 (класс ЭМС A)
J 55014
Класс защиты
IP 21
Знаки соответствия стандартам
см. заводскую табличку зарядного
устройства
Масса, включая сетевой и зарядный
провода
6,5 кг
14,33 фунта
Размеры (Ш x В x Г)
315 x 200 x 110 мм
12,40 x 7,87 x 4,33 дюйма
83
FI
Hyvä lukija,
Einleitung
Wir danken Ihnen für Ihr entgegengebrachtes Vertrauen und gratulieren Ihnen zu Ihrem
technisch hochwertigen Fronius Produkt. Die vorliegende Anleitung hilft Ihnen, sich mit
diesem vertraut zu machen. Indem Sie die Anleitung sorgfältig lesen, lernen Sie die vielfäl-
tigen Möglichkeiten Ihres Fronius-Produktes kennen. Nur so können Sie seine Vorteile
bestmöglich nutzen.
Bitte beachten Sie auch die Sicherheitsvorschriften und sorgen Sie so für mehr Sicherheit
am Einsatzort des Produktes. Sorgfältiger Umgang mit Ihrem Produkt unterstützt dessen
langlebige Qualität und Zuverlässigkeit. Das sind wesentliche Voraussetzungen für her-
vorragende Ergebnisse.
84
Sicherheitsvorschriften
Erklärung Sicher-
heitshinweise
Wenn Sie eines der im Kapitel „Sicherheitsvorschriften“ abgebildeten Symbole sehen, ist
erhöhte Achtsamkeit erforderlich.
Yleistä
VAARA! Bezeichnet eine unmittelbar drohende Gefahr. Wenn sie nicht gemie-
den wird, sind Tod oder schwerste Verletzungen die Folge.
VAROITUS! Bezeichnet eine möglicherweise gefährliche Situation. Wenn sie
nicht gemieden wird, können Tod und schwerste Verletzungen die Folge sein.
VARO! Bezeichnet eine möglicherweise schädliche Situation. Wenn sie nicht ge-
mieden wird, können leichte oder geringfügige Verletzungen sowie Sachschäden
die Folge sein.
HUOMIO! Bezeichnet die Gefahr beeinträchtigter Arbeitsergebnisse und mögli-
cher Schäden an der Ausrüstung.
TÄRKEÄÄ! Bezeichnet Anwendungstipps und andere besonders nützliche Informationen.
Es ist kein Signalwort für eine schädliche oder gefährliche Situation.
Laite on valmistettu uusimman teknisen tietämyksen ja yleisesti hyväksyttyjen
turvallisuusteknisten sääntöjen mukaisesti. Laitteen väärä ja epäasianmukai-
nen käyttö voi silti aiheuttaa
—
hengen- ja onnettomuusvaaran käyttäjälle tai kolmannelle osapuolelle
—
laitevaurioiden ja muiden aineellisten vahinkojen vaaran omistajalle
—
laitteen tehon heikentymisen.
Kaikkien laitteen käyttöönottoon, käyttöön, huoltoon ja kunnossapitoon osal-
listuvien on
—
oltava päteviä tehtäväänsä
—
osattava toimia varaajien ja akkujen kanssa
—
luettava käyttöohje kokonaan ja noudatettava sitä.
Käyttöohje on säilytettävä aina laitteen käyttöpaikassa. Käyttöohjeen lisäksi
on noudatettava voimassa olevia paikallisia tapaturmantorjunta- ja ympäris-
tönsuojelumääräyksiä.
Laitteen turvallisuus- ja varoitusmerkinnät
—
Merkit on pidettävä luettavassa kunnossa.
—
Merkkejä ei saa vaurioittaa.
—
Merkkejä ei saa poistaa.
—
Merkkejä ei saa peittää.
Laitteeseen merkittyjen turvallisuus- ja varoitusmerkintöjen paikat on kerrottu
laitteen käyttöohjeen kohdassa Yleisiä tietoja.
Turvallisuutta haittaavat häiriöt voi täytyy korjata ennen laitteen päällekytke-
mistä.
Kyseessä on oma turvallisuutesi.
85
FI
Bestimmungsge-
mäße Verwen-
dung
Umgebungsbe-
dingungen
Netzanschluss
Gefahren durch
Netz- und La-
destrom
Das Gerät ist ausschließlich für den Einsatz im Sinne der bestimmungsge-
mäßen Verwendung zu benutzen. Eine andere oder darüber hinaus gehende
Benutzung gilt als nicht bestimmungsgemäß. Für hieraus entstandene Schä-
den, sowie für mangelhafte oder fehlerhafte Arbeitsergebnisse haftet der
Hersteller nicht.
Zur bestimmungsgemäßen Verwendung gehört auch
—
das vollständige Lesen und Befolgen der Bedienungsanleitung und aller
Sicherheits- und Gefahrenhinweise
—
die Einhaltung der Inspektions- und Wartungsarbeiten
—
die Einhaltung aller Hinweise der Batterie- und Fahrzeughersteller
Betrieb oder Lagerung des Gerätes außerhalb des angegebenen Bereiches
gilt als nicht bestimmungsgemäß. Für hieraus entstandene Schäden haftet
der Hersteller nicht.
Genaue Informationen über die zulässigen Umgebungsbedingungen entneh-
men Sie den technischen Daten Ihrer Bedienungsanleitung.
Geräte mit hoher Leistung können auf Grund ihrer Stromaufnahme die Ener-
giequalität des Netzes beeinflussen.
Das kann einige Gerätetypen betreffen in Form von:
—
Anschluss-Beschränkungen
—
Anforderungen hinsichtlich maximal zulässiger Netzimpedanz
*)
—
Anforderungen hinsichtlich minimal erforderlicher Kurzschluss-Leistung
*)
*)
jeweils an der Schnittstelle zum öffentlichen Netz
siehe technische Daten
In diesem Fall muss sich der Betreiber oder Anwender des Gerätes ver-
sichern, ob das Gerät angeschlossen werden darf, gegebenenfalls durch
Rücksprache mit dem Energieversorgungs-Unternehmen.
Beim Arbeiten mit Ladegeräten setzen Sie sich zahlreichen Gefahren aus, wie
z.B.:
—
elektrische Gefährdung durch Netz- und Ladestrom
—
schädliche elektromagnetische Felder, die für Träger von herzschritt-
machern Lebensgefahr bedeuten können
86
Gefahr durch Sä-
uren, Gase und
Dämpfe
Allgemeine Hin-
weise zum Um-
gang mit
Batterien
Ein elektrischer Schlag kann tödlich sein. Jeder elektrische Schlag ist grund-
sätzlich lebensgefährlich. Um elektrische Schläge während des Betriebes zu
vermeiden:
—
keine spannungsführenden Teile innerhalb und außerhalb des Gerätes
berühren.
—
keinesfalls die Batteriepole berühren
—
Ladekabel oder Ladeklemmen nicht kurzschließen
Sämtliche Kabel und Leitungen müssen fest, unbeschädigt, isoliert und aus-
reichend dimensioniert sein. Lose Verbindungen, angeschmorte, beschädigte
oder unterdimensionierte Kabel und Leitungen sofort von einem autorisierten
Fachbetrieb instandsetzen lassen.
Batterien enthalten augen- und hautschädigende Säuren. Zudem entstehen
beim Laden von Batterien Gase und Dämpfe, die Gesundheitsschäden verur-
sachen können und die unter gewissen Umständen hoch explosiv sind.
—
Ladegerät ausschließlich in gut belüfteten Räumen verwenden, um das
Ansammeln von explosiven Gasen zu verhindern. Batterieräume gelten
nicht als explosionsgefährdet, wenn durch natürliche oder technische Lüf-
tung eine Wasserstoffkonzentration unter 4 % gewährleistet ist.
—
Während des Ladens einen Mindestabstand von 0,5 m (19.69 in.) zwi-
schen Batterie und Ladegerät einhalten. Mögliche Zündquellen sowie
Feuer und offenes Licht von der Batterie fernhalten
—
Die Verbindung zur Batterie (z.B. Ladeklemmen) keinesfalls während des
Ladevorganges abklemmen
—
Entstehende Gase und Dämpfe keinesfalls einatmen
—
Für ausreichend Frischluftzufuhr sorgen.
—
Keine Werkzeuge oder elektrisch leitende Metalle auf die Batterie legen,
um Kurzschlüsse zu vermeiden
—
Batteriesäure darf keinesfalls in die Augen, auf Haut oder Kleidung gera-
ten. Schutzbrillen und geeignete Schutzkleidung tragen. Säurespritzer
sofort und gründlich mit klarem Wasser abspülen, notfalls Arzt aufsuchen.
—
Batterien vor Schmutz und mechanischer Beschädigung schützen.
—
Aufgeladene Batterien in kühlen Räumen lagern. Bei ca. +2 °C (35.6 °F)
besteht die geringste Selbstentladung.
—
Durch wöchentliche Sichtprüfung sicherstellen, dass Batterie bis zur max.
Markierung mit Säure (Elektrolyt) gefüllt ist.
—
Betrieb des Gerätes nicht starten oder sofort stoppen und Batterie von au-
torisierter Fachwerkstätte überprüfen lassen bei:
—
ungleichmäßigem Säurestand oder hohem Wasserverbrauch in einzel-
nen Zellen, hervorgerufen durch einen möglichen Defekt.
—
unzulässiger Erwärmung der Batterie über 55 °C (131 °F).
87
FI
Selbst- und Per-
sonenschutz
Sicherheitsmaß-
nahmen im Nor-
malbetrieb
EMV Geräte-Klas-
sifizierungen
EMV-Maßnahmen
Personen, vor allem Kinder, während des Betriebes vom Gerät und vom Ar-
beitsbereich fernhalten. Befinden sich dennoch Personen in der Nähe
—
diese über alle Gefahren (gesundheitsschädliche Säuren und Gase,
Gefährdung durch Netz- und Ladestrom, …) unterrichten,
—
geeignete Schutzmittel zur Verfügung stellen.
Vor Verlassen des Arbeitsbereiches sicherstellen, dass auch in Abwesenheit
keine Personen- oder Sachschäden auftreten können.
—
Geräte mit Schutzleiter nur an einem Netz mit Schutzleiter und einer Steck-
dose mit Schutzleiter-Kontakt betreiben. Wird das Gerät an einem Netz
ohne Schutzleiter oder an einer Steckdose ohne Schutzleiterkontakt betrie-
ben, gilt dies als grob fahrlässig. Für hieraus entstandene Schäden haftet
der Hersteller nicht.
—
Das Gerät nur gemäß der am Leistungsschild angegebenen Schutzart bet-
reiben.
—
Das Gerät keinesfalls in Betrieb nehmen, wenn es Beschädigungen auf-
weist.
—
Sicherstellen, dass die Kühlluft ungehindert durch die Luftschlitze am Gerät
ein- und austreten kann.
—
Netz- und Gerätezuleitung regelmäßig von einer Elektro-Fachkraft auf
Funktionstüchtigkeit des Schutzleiters überprüfen lassen.
—
Nicht voll funktionstüchtige Sicherheitseinrichtungen und Bauteile in nicht
einwandfreiem Zustand vor dem Einschalten des Gerätes von einem auto-
risierten Fachbetrieb instandsetzen lassen.
—
Schutzeinrichtungen niemals umgehen oder außer Betrieb setzen.
—
Nach dem Einbau ist ein frei zugänglicher Netzstecker erforderlich.
Geräte der Emissionsklasse A:
—
sind nur für den Gebrauch in Industriegebieten vorgesehen
—
können in anderen Gebieten leitungsgebundene und gestrahlte
Störungen verursachen.
Geräte der Emissionsklasse B:
—
erfüllen die Emissionsanforderungen für Wohn- und Industrie-
gebiete. Dies gilt auch für Wohngebiete, in denen die Energie-
versorgung aus dem öffentlichen Niederspannungsnetz erfolgt.
EMV Geräte-Klassifizierung gemäß Leistungsschild oder techni-
schen Daten.
In besonderen Fällen können trotz Einhaltung der genormten Emissions-
Grenzwerte Beeinflussungen für das vorgesehene Anwendungsgebiet auftre-
ten (z.B. wenn empfindliche Geräte am Aufstellungsort sind oder wenn der
Aufstellungsort in der Nähe von Radio- oder Fernsehempfängern ist).
In diesem Fall ist der Betreiber verpflichtet, angemessene Maßnahmen für die
Störungsbehebung zu ergreifen.
88
Tietojen varmis-
tukset
Wartung und In-
standsetzung
Gewährleistung
und Haftung
Sicherheits-
technische Über-
prüfung
Käyttäjä on vastuussa tehdasasetuksista poikkeavien muutosten tallentami-
sesta. Valmistaja ei ota vastuuta yksilöllisten asetusten tuhoutumisesta.
Das Gerät benötigt unter normalen Betriebsbedingungen nur ein Minimum an
Pflege und Wartung. Das Beachten einiger Punkte ist jedoch unerlässlich, um
es über Jahre hinweg einsatzbereit zu halten.
—
Vor jeder Inbetriebnahme Netzstecker und Netzkabel sowie Ladeleitun-
gen und Ladeklemmen auf Beschädigung prüfen.
—
Bei Verschmutzung Gehäuseoberfläche des Gerätes mit weichem Tuch
und ausschließlich mit lösungsmittelfreien Reinigungsmitteln reinigen
Reparatur- und Instandsetzungsarbeiten dürfen ausschließlich durch einen
autorisierten Fachbetrieb erfolgen. Nur Original-Ersatz- und Verschleißteile
verwenden (gilt auch für Normteile). Bei fremdbezogenen Teilen ist nicht
gewährleistet, dass diese beanspruchngs- und sicherheitsgerecht konstruiert
und gefertigt sind.
Ohne Genehmigung des Herstellers keine Veränderungen, Ein- oder Umbau-
ten am Gerät vornehmen.
Die Entsorgung nur gemäß den geltenden nationalen und regionalen Bestim-
mungen durchführen.
Die Gewährleistungszeit für das Gerät beträgt 2 Jahre ab Rechnungsdatum.
Der Hersteller übernimmt jedoch keine Gewährleistung, wenn der Schaden
auf eine oder mehrere der folgenden Ursachen zurückzuführen sind:
—
Nicht bestimmungsgemäße Verwendung des Gerätes
—
Unsachgemäßes Montieren und Bedienen
—
Betreiben des Gerätes bei defekten Schutzeinrichtungen
—
Nichtbeachten der Hinweise in der Bedienungsanleitung
—
Eigenmächtige Veränderungen am Gerät
—
Katastrophenfälle durch Fremdkörpereinwirkung und höhere Gewalt
Der Hersteller empfiehlt, mindestens alle 12 Monate eine sicherheitstechni-
sche Überprüfung am Gerät durchführen zu lassen.
Eine sicherheitstechnische Überprüfung durch eine geprüfte Elektro-Fach-
kraft wird empfohlen
—
nach Veränderung
—
nach Ein- oder Umbauten
—
nach Reparatur, Pflege und Wartung
—
mindestens alle zwölf Monate.
Für die sicherheitstechnische Überprüfung die entsprechenden nationalen
und internationalen Normen und Richtlinien befolgen.
Nähere Informationen für die sicherheitstechnische Überprüfung erhalten Sie
bei Ihrer Servicestelle. Diese stellt Ihnen auf Wunsch die erforderlichen Unter-
lagen zur Verfügung.
Комментарии
Do you have a Fronius inverter? If so, bookmark this post now. Before doing anything else, it’s about to become your new best friend should one of these Fronius inverter state codes arise. If however, you’re experiencing a warning instance now, your Fronius solar inverter is likely to be displaying a particular code that is fairly uninterpretable without this guide.
Find your Fronius inverter state codes with ease, follow this process;
1. Record the number (or numbers) displayed on the inverter.
2. Jump to the relevant Fronius inverter state code selection using one of the buttons below.
3. (example) if error code 502 is displayed, tap the 5xx button below, locate 502 and select the State Code – #502 tab.
Need additional insight? Post your Fronius inverter state codes and related question within the comments at the bottom of this post.
Tap one of the bellow buttons to jump to your Fronius inverter state codes;
If you’re experiencing an issue, don’t worry Fronius make excellent solar inverter technologies. Chances are something external could be Influencing the state code. After all, this intelligent piece of equipment is potentially just protecting itself from a critical failure.
LIVE POLL: Most common Fronius inverter state codes.
Your Fronius inverter state codes matter. Contribute to a global audience with Solar Analitica Polls and compare how common your Fronius inverter state codes are;
Safe select with Solar Analytica® Polls.
#1xx
Fronius inverter STATE codes.
Description: The AC voltage is too high.
What to do: Contact your solar installer.
Description: The AC voltage is too low.
What to do: Contact your solar installer.
Description: The AC frequency is too high.
What to do: Contact your solar installer.
Description: The AC frequency is too low.
What to do: Contact your solar installer.
Description: The AC grid outside the allowed limits.
What to do: Contact your solar installer.
Description: Independent operation detected.
What to do: Contact your solar installer.
Description: A residual current monitoring unit (RCMU) error has occurred.
What to do: Contact your solar installer.
Description: Grid frequency jump too high.
What to do: This value can be adjusted to the grid via menupoint RoCoF (Rate of Change of Frequency) in the Profi Menu. Alternatively, contact your solar installer.
#2xx
Fronius inverter STATE codes.
Description: Over-voltage on Line 1.
What to do: This fault will fix itself; If the fault keeps showing, contact your solar installer.
Description: Under-voltage on Line 1.
What to do: This fault will fix itself; if the fault keeps showing, contact your solar installer.
Description: Over-voltage on Line 2.
What to do: This fault will fix itself; if the fault keeps showing, contact your solar installer.
Description: Under-voltage on Line 2.
What to do: This fault will fix itself; if the fault keeps showing, contact your solar installer.
Description: Over-voltage on Line 3.
What to do: This fault will fix itself; if the fault keeps showing, contact your solar installer.
Description: Under-voltage on Line 3.
What to do: This fault will fix itself; if the fault keeps showing, contact your solar installer.
Description: Arc detected.
What to do: If the fault keeps showing, contact your solar installer.
Description: Arc detected. This code will display immediately after State Code 240.
What to do: If the fault keeps showing, contact your solar installer.
Description: Arc detected. This code will display immediately after State Code 241 is reset.
What to do: If the fault keeps showing, contact your solar installer.
Description: Self-test failure for Arc detection.
What to do: Perform AC reset, repeat test; If the fault keeps showing, contact your solar installer.
Description: Faulty current sensor for Arc detector.
What to do: If the fault keeps showing, contact your solar installer.
Description: Faulty Arc detector.
What to do: If the fault keeps showing, contact your solar installer.
#3xx
Fronius inverter STATE codes.
Description: Excess AC current
What to do: This fault will fix itself; If the fault keeps showing, contact your solar installer.
Description: Excess DC current.
What to do: This fault will fix itself; If the fault keeps showing, contact your solar installer.
Description: DC module overheating.
What to do: This fault will fix itself; If the fault keeps showing, contact your solar installer.
Description: AC module overheating.
What to do: This fault will fix itself; If the fault keeps showing, contact your solar installer.
Description: Power is not being fed in, although the relay is closed.
What to do: This fault will fix itself; If the fault keeps showing, contact your solar installer.
Description: The PV output is too low to feed.
What to do: This fault will fix itself; If the fault keeps showing even when sufficient sunlight contact your solar installer.
NOTE: These codes are shown at morning and night because of the low levels of sunlight at these times.
Description: The PV output is too low to feed.
What to do: Contact your solar installer.
NOTE: These codes are shown at morning and night because of the low levels of sunlight at these times.
Description: The intermediate circuit voltage is too high.
What to do: This fault will fix itself; If the fault keeps showing contact your solar installer.
Description: The DC input voltage MPPT (maximum power point tracker) 1 is too high.
What to do: This fault will fix itself; If the fault keeps showing contact your solar installer.
Description: The polarity of the DC strings reversed.
What to do: The fault will fix itself; If the fault keeps showing, contact your solar installer.
Description: The DC input voltage MPPT (maximum power point tracker) 2 is too high.
What to do: The fault will fix itself; If the fault keeps showing, contact your solar installer.
Description: Current sensor calibration timeout.
What to do: The fault will fix itself; If the fault keeps showing, contact your solar installer.
Description: AC current sensor error.
What to do: Contact your solar installer.
Description: Interrupt check fail.
What to do: Contact your solar installer.
Description: Unbalanced Intermediate circuit voltage.
What to do: Contact your installer.
Description: DC back current detected.
What to do: Contact your installer.
Description: Connection area overheating.
What to do: Contact your solar installer.
Description: Error with fan 1
What to do: Contact your solar installer.
Description: Error with fan 2
What to do: Contact your solar installer.
#4xx
Fronius inverter STATE codes.
Description: Unable to communicate with the power stage set.
What to do: Contact your solar installer.
Description: Temperature sensor for AC module is faulty (L1)
What to do: Contact your solar installer.
Description: Temperature sensor for AC module is faulty (L2)
What to do: Contact your solar installer.
Description: DC component measured in the grid is too high.
What to do: Contact your solar installer.
Description: Fixed voltage mode has selected instead of MPP voltage mode and the fixed voltage mode has been set at the wrong value.
What to do: If this code keeps showing contact your solar installer.
Description: Safety cut out has triggered via option card or RECERBO.
What to do: Contact your solar installer.
Description: Power stage set has no communication with control system.
What to do: Contact your solar installer.
Description: Hardware ID issue.
What to do: Update the inverter firmware.
Description: Unique ID issue.
What to do: Update the inverter firmware.
Description: Unable to communicate with Fronius Datamanager.
What to do: Update the inverter firmware.
Description: HID range error.
What to do: Update the inverter firmware.
Description: Unable to communicate with power stage set.
What to do: Update the inverter firmware.
Description: Hardware fault.
What to do: Update the inverter firmware.
Description: Software fault.
What to do: Conduct an AC reset (switch the AC circuit breaker off and on); update the inverter firmware, if the fault code keeps showing contact your solar installer.
Description: Functional incompatibility.
What to do: Update the inverters firmware; if the fault keeps showing, contact your solar installer.
Description: Power stage fault.
What to do: Update the inverters firmware; if the fault keeps showing, contact your solar installer.
Description: Functional incompatability.
What to do: Update the inverters firmware; if the fault keeps showing, contact your solar installer.
Description: The intermediate circuit voltage is too low or asymmetric.
What to do: If the fault keeps showing, contact your solar installer.
Description: Compatibility fault – Invalid power stage set configuration.
What to do: Update the inverter firmware, if the fault keeps showing, contact your solar installer.
Description: Insulation problem.
What to do: If the fault keeps showing, contact your solar installer.
Description: The neutral conductor is not connected.
What to do: If the fault keeps showing, contact your solar installer.
Description: The guard can’t be found.
What to do: If the fault keeps showing, contact your solar installer.
Description: Memory fault detected.
What to do: If the fault keeps showing, contact your solar installer.
Description: Communication problem between processors.
What to do: If the fault keeps showing, contact your solar installer.
Description: Power stage set and grid voltage are not compatible.
What to do: If the fault keeps showing, contact your solar installer.
Description: Power stage set and grid frequency are not compatible.
What to do: If the fault keeps showing, contact your solar installer.
Description: Anti-islanding function is no longer implemented correctly.
What to do: If the fault keeps showing, contact your solar installer.
Description: The grid relay sticking or the neutral conductor ground voltage is too high.
What to do: Check grounding (neutral conductor ground voltage has to be less than 30V); If code keeps showing, contact your solar installer.
Description: Issues when recording the measuring signal.
What to do: Contact your solar installer
Description: Issues when recording the measuring signal for insulation test.
What to do: Contact your solar installer
Description: Reference voltage source for the DSP (digital signal processor) is working out of tolerance.
What to do: Contact your solar installer
Description: Error in the DSP (digital signal processor) data memory.
What to do: Contact your solar installer
Description: Fault with the DC feed monitoring routine.
What to do: Contact your solar installer
Description: Reversed AC polarity, the AC connector has been incorrectly inserted.
What to do: Contact your solar installer
Description: The RCMU sensor is faulty.
What to do: Contact your solar installer
Description: Insulation fault (The connection between the solar panel and the ground is faulty)
What to do: Contact your solar installer
Description: The driver supply voltage is too low.
What to do: Contact your solar installer
Description: Intermediate circuit relay has switched off.
What to do: Contact your solar installer.
Description: Functional incompatibility (One or more PC boards in the inverter are not compatible together).
What to do: Update the inverters firmware, if the code keeps showing , contact your solar installer.
Description: The setup phase after the initial start-up was interrupted.
What to do: Conduct and AC reset (turn off the AC circuit breaker, and then back on) Complete the start-up.
Description: The voltage UDC fixed on MPP2 string is out of limits.
What to do: Check MPP settings, if this code keeps showing contact your solar installer.
Description: The CAN transmit buffer is full.
What to do: Conduct an AC reset (turn the AC circuit breaker off and then back on again). Contact your solar installer if this code persists.
Description: Permanent intermediate circuit capacitor overvoltage.
What to do: Contact your solar installer.
#5xx
Fronius inverter STATE codes.
Description: Insulation fault on the solar panels.
What to do: If the code keeps showing, contact your solar installer.
Description: No energy has been fed into the grid in the last 24 hours.
What to do: Check for any other state code, if none, contact your solar installer.
Description: Unable to communicate with filter.
What to do: If the code keeps showing, contact your solar installer.
Description: Unable to communicate with storage unit.
What to do: If the code keeps showing, contact your solar installer.
Description: Overheating which is causing power derating.
What to do: Purge cooling air openings, the fault will fix itself; If the code keeps showing, contact your solar installer.
Description: Internal DSP fault.
What to do: If this code keeps showing, contact your solar installer.
Description: Unable to communicate with storage unit.
What to do: If this code keeps showing, contact your solar installer.
Description: No energy has been fed into the grid by MPPT1 in the past 24 hours.
What to do: If this code keeps showing, contact your solar installer.
Description: The DC is low in string 1.
What to do: If the code keeps showing, contact your solar installer.
Description: The DC is low in string 2.
What to do: If the code keeps showing, contact your solar installer.
Description: There is a functional incompatibility (one or more of the PC boards are not compatible).
What to do: Update the inverters firmware; if this code keeps showing, contact your solar installer.
Description: The grid frequency has become excessively high which is causing power derating.
What to do: This fault will fix itself, if the code keeps showing, contact your solar installer.
Description: There is a functional incompatibility (one or more of the PC boards are not compatible).
What to do: Update the inverters firmware; if this code keeps showing, contact your solar installer.
Description: The arc detector has been deactivated.
What to do: No Error. Press enter (4th button from the left) to confirm status code.
Description: The GVDPR (grid voltage depedent power reduction mode) is active and the inverter will operate with reduced power output.
What to do: If this code keeps showing, contact your solar installer.
Description: Incorrect input signal on the multifunction current interface.
What to do: Check the devices connected to the multifunction current interface; If this code keeps showing, contact your solar installer.
Description: Power is limited by the power stage set.
What to do: If this code keeps showing, contact your solar installer.
Description: Low temperature warning.
What to do: If this code keeps showing, contact your solar installer.
Description: Special Purpose Utility-Inter- active (SPUI) setup activated.
What to do: No error. Press enter (4th button from the left) to confirm status code.
#6xx
Fronius inverter STATE codes.
Description: The CAN bus is full.
What to do: Update your inverters firmware; If the code keeps showing, contact your solar installer.
Description: The AC module temperature sensor is faulty.
What to do: If the code keeps showing, contact your solar installer.
Description: The DC module sensor is faulty.
What to do: If the code keeps showing, contact your solar installer.
Description: RCMU fault.
What to do: Press enter (4th button from your left) to reset status code; If the code keeps showing, contact your solar installer.
Description: There is a functional incompatibility (one or more of the PC board are not compatible).
What to do: Update your inverters firmware; If this code keeps showing, contact your solar installer.
Description: Configuration Value Out of Limits .
What to do: Seek intervention by a Fronius-trained service engineer.
#7xx
Fronius inverter STATE codes.
Description: Information about the internal processors status.
What to do: If the code keeps showing, contact your solar installer.
Description: Issue when setting the inverter number.
What to do: Correct inverter number in Setup menu; If the code keeps showing, contact your solar installer.
Description: Information about the internal processors status.
What to do: If the code keeps showing, contact your solar installer.
Description: EEPROM has been re-initialised.
What to do: If the code keeps showing, contact your solar installer.
Description: Information about the internal processors status.
What to do: If the code keeps showing, contact your solar installer.
Description: Initialisation error – USB flash drive not supported.
What to do: Check the USB flash drive and the files, if necessary, replace.
Description: Initialisation error with USB flash drive.
What to do: Check the USB flash drive and the files, if necessary, replace.
Description: USB flash drive not connected.
What to do: Check the USB flash drive and the files, if necessary, replace; If the code keeps showing, contact your solar installer.
Description: Update file not recognised or missing.
What to do: Check the update file for issues; If the code keeps showing, contact your solar installer.
Description: Update file is too old or does not match the device.
What to do: Check the update file for issues, if necessary change file to match device; If the code keeps showing, contact your solar installer.
Description: Write or read error.
What to do: Check the USB flash drive and contents, replace if necessary; If the code keeps showing, contact your solar installer.
Description: Unable to open file.
What to do: Check the USB flash drive and contents, replace if necessary; If the code keeps showing, contact your solar installer.
Description: Unable to save log file.
What to do: Create space on USB flash drive;Check the USB flash drive and contents, replace if necessary; If the code keeps showing, contact your solar installer.
Description: Error in file system on USB flash drive.
What to do: Check the USB flash drive and contents, replace if necessary; If the code keeps showing, contact your solar installer.
Description: Error recording logging data.
What to do: Check the USB flash drive and contents, replace if necessary; If the code keeps showing, contact your solar installer.
Description: Error during update.
What to do: Try update again, check USB flash drive and replace if necessary; If the code keeps showing, contact your solar installer.
Description: The update file is corrupt.
What to do: Re-download update file, check USB flash drive and replace if necessary; If the code keeps showing, contact your solar installer.
Description: Error while updating.
What to do: Wait a few minutes and try updating again; If the code keeps showing, contact your solar installer.
Description: Time lost.
What to do: Reset the time and date on the inverter; If the code keeps showing, contact your solar installer.
Description: Communication error with real time clock module.
What to do: Reset the time and date on the inverter; If the code keeps showing, contact your solar installer.
Description: The real time clock module is in emergency mode
What to do: Reset the time and date on the inverter; If the code keeps showing, contact your solar installer.
Description: Information about the processors status.
What to do: If the code keeps showing, contact your solar installer.
Description: Real time clock module hardware error.
What to do: If the code keeps showing, contact your solar installer.
Description: Real time clock module is in emergency mode.
What to do: Reset the time and date on your inverter.
Description: Internal hardware fault.
What to do: If this code keeps showing, contact your solar installer.
Description: Information about the internal processors status.
What to do: If this code keeps showing, contact your solar installer.
Description: Emergency power derating has triggered.
What to do: If this code keeps showing, contact your solar installer.
Description: Information about the internal processors status.
What to do: If this code keeps showing, contact your solar installer.
Description: There is contrasting power limitation in the hardware modules
What to do: If this code keeps showing, contact your solar installer.
Description: Storage unit unavailable.
What to do: If this code keeps showing, contact your solar installer.
Description: Invalid country setup.
What to do: If this code keeps showing, contact your solar installer.
Description: The PMC power stage set unavailable.
What to do: Press the enter key(4th button on your from left); If this code keeps showing, contact your solar installer.
Description: The device type is invalid.
What to do: Press the enter key(4th button on your from left); If this code keeps showing, contact your solar installer.
Description: CAN bus transmission error.
What to do: Contact your solar installer.
Description: Information about the internal processors status.
What to do: If this code keeps showing, contact your solar installer.
#9xx
Fronius inverter STATE codes.
Description: Inconsistent software on device.
What to do: Update inverter firmware; If the code keeps showing, contact your solar installer.
Description: Unregistered battery module detected.
What to do: Enter activation key for battery module; If the code keeps showing, contact your solar installer.
Description: Incorrect number of battery modules connected to Fronius solar battery.
What to do: Enter activation key for battery module; If the code keeps showing, contact your solar installer.
Description: Communication fault between Fronius solar battery and Fronius Symo hybrid.
What to do: If the code keeps showing, contact your solar installer.
Description: No communication between Fronius solar battery and Fronius Symo hybrid.
What to do: Switch on Fronius solar battery; If the code keeps showing, contact your solar installer.
Description: Inconsistent software version for Fronius solar battery.
What to do: If the code keeps showing, contact your solar installer.
Description: Communication fault between battery controller and battery modules.
What to do: If the code keeps showing, contact your solar installer.
Description: Charge mode on battery controller has stopped.
What to do: If the code keeps showing, contact your solar installer.
Description: Under-voltage ate Fronius battery.
What to do: If the code keeps showing, contact your solar installer.
Description: Over-temperature at Fronius solar battery.
What to do: Reduce ambient temperature; Switch off Fronius solar battery and after some time switch back on; If the code keeps showing, contact your solar installer.
Description: Under-temperature at Fronius solar battery.
What to do: Increase ambient temperature; Switch off Fronius solar battery and after some time switch back on; If the code keeps showing, contact your solar installer.
Description: Communication fault between Smart meter and Fronius Symo hybrid.
What to do: If the code keeps showing, contact your solar installer.
Description: No communication between Smart meter and Fronius Symo hybrid.
What to do: If the code keeps showing, contact your solar installer.
Description: Status code 994 is registered if there is no data available for the “Earnings comparison” function that can be compared.
What to do: Check Solar.web under “Settings” –> “Components” to see whether the DC power of the inverters has been specified correctly. Check the settings for the “Earnings comparison” function under “Settings” –> “Service Messages”. Check that the settings for deviation, threshold and inverter selection (DC channels) have been correctly stored. Your installer can give you the correct values and settings.
If you are unable to solve the problem yourself, or if you are unsure of a point, please contact your installer.
Description: The status code 995 is registered on Fronius Solar.web if no data is received from the storage system for a specified time.
What to do: You can manually adjust the time period for receiving this service message on Fronius Solar.web under “Settings”–> “Service messages” –> “Battery blackout detection”. Please note that live data (bubble chart) is not taken into account. Verify that the storage system has been set to “Standby” mode. Check whether your Fronius Solar.web system might be “offline” and whether other status codes have been registered under “Service messages.” If your system is “offline”, please navigate to the “Solar.web offline” area. If your system is “online” and the status of the storage system is not in “Standby” mode, please contact your installer immediately.
Description: Status code 996 is an indicator of a communication error between the inverter and Fronius Solar.web.
What to do: If the connection to the inverter fails due to an unstable Internet connection, you can increase the blackout detection time on Solar.web under “Settings” –> “Service messages” –> “Edit”. Increase the blackout detection period to at least 12 hours. If your system is “offline” for more than 12 hours, check that your router is turned on and that there is an Internet connection. Restart your router. If your system is still offline, do the following:
- De-energise the inverter on the AC side (circuit breaker or residual current circuit breaker, etc.).
- Switch the DC disconnector below the inverter to the “O” (Off) position.
- Wait a few minutes.
- Switch the DC disconnector back on. Then switch on the grid on the AC side (secure circuit breakers and residual current circuit breakers).
- If your system is still offline, open the Datamanager web interface and reconnect to your home network (router). Under “Settings” à, select “Network” and select your network.”
Description: Status code 997 is triggered on Fronius Solar.web by the “Earnings comparison” function.
What to do: If there is a defect on the PV generator side or if your PV modules are covered with snow, you will receive this status code as a result. Check Fronius Solar.web under “Settings” –> “Components” to see if the DC power of the inverters has been specified correctly. If you are unsure whether the values are displayed correctly, contact your installer.
Description: Status code 999 is triggered by Fronius Solar.web if inverter data is not recorded on Solar.web for a certain period of time.
What to do: You can adjust the time span under “Settings” –> “Service messages” –> “Inverter blackout detection”. Check the “DATCOM status” on the display of the inverter under “Setup” –> “DATCOM”. If the status is “Error”, contact your installer.
#10xx — 12xx
Fronius inverter STATE codes.
Description: If the inverter is working properly and only appears in the set up parameters, it is of no concern.
What to do: In the event of an error and the code keeps showing, contact your solar installer. This status code will assist Fronius technical support for analysis.
LIVE POLL: Most common Fronius inverter state codes.
Haven’t contributed yet? Your Fronius inverter state codes matter. Contribute to a global audience with Solar Analitica Polls and compare how common your Fronius inverter fault codes are;
Safe select with Solar Analytica® Polls.
Reference.
We love Fronius inverters. A testament to fine technology, often Fronius inverter state codes evolve with new firmware updates to better accommodate your regional electricity supply or alternative system parameters to ensure enhanced operation. Below are the most up to date (at the time of writing) reference materials used to compile this easily accessible online information.
- Fronius global download centre (external site).
- Fronius Primo single-phase manual.
- Fronius Symo & Eco three-phase manual.
- Fronius Symo three-phase manual.