GBIC_SECURITY_CRYPT
%GBIC_SECURITY_CRYPT-4-UNRECOGNIZED_VENDOR : GBIC in port [dec] manufactured by an unrecognized vendor | |
---|---|
Explanation | The GBIC was identified as a Cisco GBIC, but the system was unable to match its manufacturer with one on the known list of Cisco GBIC vendors |
Recommended Action | Check to see if the Cisco IOS software running on the system supports the GBIC. If the GBIC is newer, a system software upgrade might be required. |
%GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR : GBIC in port [dec] has bad crc | |
---|---|
Explanation | The GBIC was identified as a Cisco GBIC, but it does not have valid CRC in the EEPROM data. |
Recommended Action
|
Check to see if the Cisco IOS software running on the system supports the GBIC. If the GBIC is newer, a system software upgrade might be required. Even if the GBIC is unrecognized by the system, the GBIC may still operate properly, but might have limited functionality. |
%GBIC_SECURITY_CRYPT-4-ID_MISMATCH : Identification check failed for GBIC in port [dec] | |
---|---|
Explanation | The GBIC was identified as a Cisco GBIC, but the system was unable to verify its identity |
Recommended Action | Check to see if the Cisco IOS software running on the system supports the GBIC. If the GBIC is newer, a system software upgrade might be required. Otherwise, verify that the GBIC was obatined from Cisco or from a supported vendor. |
GBIC_SECURITY_UNIQUE
%GBIC_SECURITY_UNIQUE-4-DUPLICATE_SN : GBIC interface [dec]/[dec] has the same serial number as another GBIC interface | |
---|---|
Explanation | The GBIC was identified as a Cisco GBIC, but its serial number matches that of another interface on the system. |
Recommended Action | Cisco GBICs are assigned unique serial numbers. Verify that the GBIC was obtained from Cisco or a supported vendor |
%GBIC_SECURITY_UNIQUE-3-DUPLICATE_GBIC : GBIC interface [dec]/[dec] is a duplicate of GBIC interface [dec]/[dec] | |
---|---|
Explanation | The GBIC was identified as a Cisco GBIC, but its vendor ID and serial number match that of another interface on the system. |
Recommended Action | Cisco GBICs are assigned unique serial numbers. Verify that the GBIC was obtained from Cisco or a supported vendor |
GDOI
%GDOI-1-GDOI_ACL_NUM : The ACL has too many entries. GDOI will honor only the first 100 ACL entries specified. | |
---|---|
Explanation | The ACL has too many entries. GDOI will honor only the first 100 ACL entries specified. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-3-GDOI_ACL_RANGE : The ACL [chars] contains port range which is NOT supported. WARNING: No TEK policy will be created. | |
---|---|
Explanation | GDOI does not support port range in the ACL policy. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-1-GDOI_ACE_DENY : A Group Member ACL policy containing deny was attempted. This is not supported. | |
---|---|
Explanation
|
A Group Member ACL policy containing deny was attempted. This is not supported. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-1-UNREGISTERED_INTERFACE : Group [chars] received registration from unregistered interface. | |
---|---|
Explanation | Receiving registration from unregistered interface. Stop processing it. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-1-UNAUTHORIZED_IDENTITY : Group [chars] received registration from unauthorized identity: [chars] | |
---|---|
Explanation | The registration request was dropped because the requesting device was not authorized to join the group. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-1-UNAUTHORIZED_IPADDR : Group [chars] received registration from unauthorized ip address: [chars] | |
---|---|
Explanation | The registration request was dropped because the requesting device was not authorized to join the group. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-4-GM_RE_REGISTER : The IPSec SA created for group [chars] may have expired/been cleared, or didn’t go through. Re-register to KS. |
|
---|---|
Explanation | The IPSec SA created for one group may have expired/been cleared, or didn’t go through, need to re-register to KS. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-GM_REGS_COMPL : Registration to KS [chars] complete for group [chars] using address [chars] fvrf [chars] ivrf [chars] | |
---|---|
Explanation
|
Complete registration |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-GM_FAILED_TO_INSTALL_POLICIES : FAILED: Installation of Reg/Rekey policies from KS [chars] for group [chars] & gm identity [chars] |
|
---|---|
Explanation | Failed Policy installation |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-GM_INSTALL_POLICIES_SUCCESS : SUCCESS: Installation of Reg/Rekey policies from KS [chars] for group [chars] & gm identity [chars] fvrf [chars] ivrf [chars] |
|
---|---|
Explanation | Policy Installation Success |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-GM_RECV_REKEY : Received Rekey for group [chars] from [chars] to [chars] with seq # [dec], spi [hex][hex] | |
---|---|
Explanation | Received Rekey |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-KS_SEND_MCAST_REKEY : Sending Multicast Rekey [chars]for group [chars] from address [chars] to [chars] with seq # [dec] spi: [hex][hex] |
|
---|---|
Explanation | Sending Multicast Rekey |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-KS_SEND_UNICAST_REKEY : Sending Unicast Rekey [chars]for group [chars] from address [chars] with seq # [dec] spi: [hex][hex] |
|
---|---|
Explanation
|
Sending Unicast Rekey |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-3-KS_BAD_ID : Registration: [chars] config mismatch between KS and the GM [IP_address], in the group [chars]. | |
---|---|
Explanation | During GDOI registration protocol, a configuration mismatch between local key server and group member. |
Recommended Action | Contact the Group member’s administrator. |
%GDOI-3-GDOI_REKEY_FAILURE : Processing of REKEY payloads failed on GM [chars] in the group [chars], with peer at [chars] | |
---|---|
Explanation | During GDOI rekey the payload parsing failed on this GM from the Key Server. |
Recommended Action | Contact the Group member’s administrator. |
%GDOI-3-GDOI_REKEY_SEQ_FAILURE : Failed to process rekey seq # [int] in seq payload for group [chars], last seq # [int] | |
---|---|
Explanation | During GDOI rekey the seq payload parsing failed on this GM from the Key Server. |
Recommended Action | Contact the Group member’s administrator. |
%GDOI-4-KS_GM_REJECTS_SA_PAYLOAD : Registration: GM [IP_address] rejected a policy in the SA proposal sent by KS, in the group [chars]. |
|
---|---|
Explanation | During GDOI registration protocol, a proposal sent by the key server was refused by the group member. |
Recommended Action | Contact the Group member’s administrator. |
%GDOI-4-GM_REJECTING_SA_PAYLOAD : Registration: Policy in SA payload sent by KS [IP_address] rejected by GM in the group [chars] reason [chars]. |
|
---|---|
Explanation
|
During GDOI registration protocol, a proposal sent by the key server was refused by the local group member. |
Recommended Action | Contact the Key server’s administrator. |
%GDOI-4-KS_HASH_FAIL : Registration: Bad(No) Hash in Message sent by the GM [IP_address] to KS in the group [chars]. | |
---|---|
Explanation | During GDOI registration protocol, a message sent by the Group member has bad or no hash . |
Recommended Action | Contact the Group member’s administrator. |
%GDOI-4-GM_HASH_FAIL : Registration: Bad(No) hash in message sent by the KS [IP_address] to GM in the group [chars]. | |
---|---|
Explanation | During GDOI registration protocol, a message sent by the Key server has bad or no hash . |
Recommended Action | Contact the Key Server’s administrator. |
%GDOI-3-KS_UNAUTHORIZED : Registration: Unauthorized [IP_address] tried to join the group [chars]. | |
---|---|
Explanation | During GDOI registration protocol, an unauthorized member tried to join a group Some might consider this a hostile event. |
Recommended Action | Contact the Key Server’s administrator. |
%GDOI-3-KS_GM_REVOKED : Re-Key: GM [IP_address] revoked by KS in the group [chars]. | |
---|---|
Explanation | During Re-key protocol, an unauthorized member tried to join a group. Some might consider this a hostile event. |
Recommended Action | Contact the Key Server’s administrator. |
%GDOI-5-KS_GROUP_ADD : Config: KS [IP_address] added to the Group [chars]. | |
---|---|
Explanation
|
A Config command has been executed to add a Key Server in a group |
Recommended Action | Informational message. |
%GDOI-5-KS_GROUP_DELETE : Config: KS [IP_address] removed from the Group [chars]. | |
---|---|
Explanation | A Config command has been executed to remove a Key Server from a group |
Recommended Action | Informational message. |
%GDOI-6-KS_FIRST_GM : Re-key: First GM [IP_address] seen by KS in the group [chars]. | |
---|---|
Explanation | Local key server has received the first group member joining the group |
Recommended Action | Informational message. |
%GDOI-6-KS_LAST_GM : Re-key: Last GM [IP_address] left the group [chars]. | |
---|---|
Explanation | Last group member has left the group on the local key server |
Recommended Action | Informational message. |
%GDOI-5-GM_CM_ATTACH : Crypto map attached for GM in group [chars]. | |
---|---|
Explanation | A crypto map has been attached for the local group member. |
Recommended Action | Informational message. |
%GDOI-5-GM_CM_DETACH : Crypto map detached for GM in group [chars]. | |
---|---|
Explanation
|
A crypto map has been detached for the local group member. |
Recommended Action | Informational message. |
%GDOI-5-GM_UNREGISTER : GM left the group [chars]. | |
---|---|
Explanation | A Group member has left the group. |
Recommended Action | Informational message. |
%GDOI-4-GM_RECV_POLICY_REPLACE_NOW : GM received policy replace now rekey from KS in group [chars]. | |
---|---|
Explanation | A messages sent by the KS to immediately replace SAs policies on the GM has been received. |
Recommended Action | Informational message. |
%GDOI-4-GM_RECV_DELETE_IMMEDIATE : GM receive REMOVAL-NOW in group [chars] to cleanup downloaded policy now. Re-registration will start in a randomly chosen period of [dec] sec |
|
---|---|
Explanation | A messages sent by the KS to delete the GM has been received. |
Recommended Action | Informational message. |
%GDOI-4-GM_RECV_RE_AUTH : GM received Re-auth-msg from KS in group [chars]. re-registration will start before SA expiry | |
---|---|
Explanation | A message sent by the KS to have a GM re-auth has been received. |
Recommended Action | Informational message. |
%GDOI-4-GM_RECV_DELETE : GM received delete-msg from KS in group [chars]. TEKs lifetime are reduced and re-registration will start before SA expiry |
|
---|---|
Explanation
|
A messages sent by the KS to delete the GM has been received. |
Recommended Action | Informational message. |
%GDOI-5-GM_CLEAR_REGISTER : Config: GM cleared gdoi configuration for the group [chars]. | |
---|---|
Explanation | clear crypto gdoi command has been executed by the local GM |
Recommended Action | Informational message. |
%GDOI-5-KS_CLEAR_REGISTER : Config: KS cleared gdoi configuration for the group [chars]. | |
---|---|
Explanation | clear crypto gdoi command has been executed by the local KS |
Recommended Action | Informational message. |
%GDOI-3-COOP_KS_UNREACH : Cooperative KS [chars] Unreachable in group [chars]. IKE SA Status = [chars] | |
---|---|
Explanation | The reachability between the configugred cooperative key servers is lost. Some might consider this a hostile event. |
Recommended Action | Contach the Administrator(s) of the configured key servers. |
%GDOI-5-COOP_KS_REACH : Reachability restored with Cooperative KS [chars] in group [chars]. | |
---|---|
Explanation | The reachability between the configugred cooperative key servers is restored. |
Recommended Action | Informational message |
%GDOI-5-COOP_KS_ADD : [chars] added as COOP Key Server in group [chars]. | |
---|---|
Explanation
|
A key server has been added to the list of cooperative key servers in a group |
Recommended Action | Informational message |
%GDOI-5-COOP_KS_REMOVE : [chars] removed as COOP Key Server in group [chars]. | |
---|---|
Explanation | A key server has been removed from the list of cooperative key servers in a group |
Recommended Action | Informational message |
%GDOI-4-COOP_KS_UNAUTH : Contact from unauthorized KS [chars] in group [chars] at local address [chars] (Possible MISCONFIG of peer/local address) |
|
---|---|
Explanation | An unauthorized remote server tried to contact the local KS may be at different key server address in a group. Some might consider this a hostile event. |
Recommended Action | Informational message |
%GDOI-5-COOP_KS_ELECTION : KS entering election mode in group [chars] (Previous Primary = [chars]) | |
---|---|
Explanation | The local Key server has entered the election process in a group |
Recommended Action | Informational message |
%GDOI-5-COOP_KS_TRANS_TO_PRI : KS [chars] in group [chars] transitioned to Primary (Previous Primary = [chars]) | |
---|---|
Explanation | The local Key server transitioned to a primary role from being a secondary server in a group |
Recommended Action | Informational message |
%GDOI-5-COOP_KS_ADMN_USRP_PRI : Primary role Usurped by KS [chars] in group [chars]. | |
---|---|
Explanation
|
A network adminstrator has made the local KS as primary, by means of a CLI command. Currently Unimplemented. |
Recommended Action | Informational message |
%GDOI-5-GM_REKEY_TRANS_2_MULTI : Group [chars] transitioned to multicast rekey. | |
---|---|
Explanation | GM has transitioned from using unicast rekey mechanism to multicast mechanism |
Recommended Action | Informational message |
%GDOI-5-KS_REKEY_TRANS_2_MULTI : Group [chars] transitioned to multicast rekey. | |
---|---|
Explanation | Group has transitioned from using unicast rekey mechanism to multicast mechanism |
Recommended Action | Informational message |
%GDOI-5-GM_REKEY_TRANS_2_UNI : Group [chars] transitioned to Unicast Rekey. | |
---|---|
Explanation | GM has transitioned from using multicast rekey mechanism to unicast mechanism |
Recommended Action | Informational message |
%GDOI-5-KS_REKEY_TRANS_2_UNI : Group [chars] transitioned to Unicast Rekey. | |
---|---|
Explanation | Group has transitioned from using multicast rekey mechanism to unicast mechanism |
Recommended Action | Informational message |
%GDOI-4-GM_REKEY_NOT_RECD : GM did not receive rekey from KS [IP_address] in group [chars]. | |
---|---|
Explanation
|
GM has not received a rekey message from a key server in a group Currently Unimplemented. |
Recommended Action | Informational message |
%GDOI-5-KS_NACK_GM_EJECT : KS ejected GM [IP_address] in group [chars]. | |
---|---|
Explanation | Key server has reached a condition of not receiving an ACK from GM and has been ejected |
Recommended Action | Informational message |
%GDOI-3-KS_BLACKHOLE_ACK : KS blackholing GM [IP_address] in group [chars]. | |
---|---|
Explanation | Key server has reached a condition of blackholing messages from GM Some might consider this a hostile event. |
Recommended Action |
%GDOI-4-KS_UNSOL_ACK : KS received unsolicited ACK from GM [IP_address] in group [chars]. | |
---|---|
Explanation | Key server has received an unsolicited ACK from a past GM or is under a DOS attack. Some might consider this a hostile event. |
Recommended Action |
%GDOI-5-KS_REGS_COMPL : KS completed successful registration in group [chars] with GM [IP_address]. | |
---|---|
Explanation | Key server has successfully completed a registration in a group |
Recommended Action |
%GDOI-5-GM_ENABLE_GDOI_CM : GM has enabled ACL on GDOI crypto map in group [chars]. | |
---|---|
Explanation
|
Group member has enabled ACL on a GDOI Crypto map in a group with a key server |
Recommended Action |
%GDOI-5-GM_ACL_MERGE : ACL betweem KS and GM in group [chars] merged. | |
---|---|
Explanation | The ACL differences between GM and KS are resolved and a merge took place |
Recommended Action |
%GDOI-5-GM_SA_INGRESS : Receive only ACL received from KS [IP_address] in group [chars]. | |
---|---|
Explanation | Received only acl has been received by GM from a KS in a group |
Recommended Action |
%GDOI-5-KS_CONV_SAS_DUPLEX : IPSec SAs converted to Duplex in group [chars]. | |
---|---|
Explanation | IPSec SAs have been converted to bidirectional mode in a group |
Recommended Action |
%GDOI-5-KS_CONV_SAS_INGRESS : IPSec SAs converted to Ingress in group [chars]. | |
---|---|
Explanation | IPSec SAs have been converted to receive only mode in a group |
Recommended Action |
%GDOI-5-GM_CONV_SA_DUPLEX : IPSec SAs converted to Duplex in group [chars] on the GM. | |
---|---|
Explanation
|
IPSec SAs have been converted to bidirectional mode in a group on a GM |
Recommended Action |
%GDOI-5-GM_CONV_SA_DUPLEX_LOCAL : IPSec SAs converted to Duplex in group [chars] on a GM by a local event. | |
---|---|
Explanation | IPSec SAs have been converted to bidirectional mode in a group on a GM by a CLI command |
Recommended Action |
%GDOI-5-LKH_ENABLE : LKH enabled in group [chars]. | |
---|---|
Explanation | LKH has been enabled in a group |
Recommended Action |
%GDOI-5-LKH_DISABLE : LKH disabled in group [chars]. | |
---|---|
Explanation | LKH has been disabled in a group |
Recommended Action |
%GDOI-4-LKH_GM_DELETE : GM [IP_address] deleted from LKH in group [chars]. | |
---|---|
Explanation | A Group member has been deleted in a group from LKH |
Recommended Action |
%GDOI-4-TIMEBASED_REPLAY_FAILED : An anti replay check has failed in group [chars]: my_pseudotime = [chars], peer_pseudotime = [chars], replay_window = [dec] (sec), src_ip = [IP_address], dst_ip = [IP_address] |
|
---|---|
Explanation
|
A Group member or Key server has failed an anti replay check. |
Recommended Action |
%GDOI-3-PIP_PSEUDO_TIME_ERROR : An Anti-Replay check has failed for PIP in group [chars]: my_pseudotime = [chars], peer_pseudotime = [chars], replay_window = %lld (sec), src_addr = [chars], dst_addr = [chars] |
|
---|---|
Explanation | A Group member has failed PIP anti replay check. |
Recommended Action |
%GDOI-3-P2P_KGS_INFRA_ERROR : PIP session with [chars] failed because of KGS Infra failure. Reason = [chars] | |
---|---|
Explanation | A Group Member has encountered a KGS Infra failure. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-4-TIMEBASED_REPLAY_FAILED_IPV6 : An anti replay check has failed in group [chars]: my_pseudotime = [chars], peer_pseudotime = [chars], replay_window = [dec] (sec), src_ip = [IPV6 address], dst_ip = [IPV6 address] |
|
---|---|
Explanation | A Group member or Key server has failed an anti replay check. |
Recommended Action |
%GDOI-3-GM_FAILED_TO_INITIALISE : GDOI GM Process has failed to initialise | |
---|---|
Explanation | GDOI Group Member process has failed to initialise on this Network Element |
Recommended Action |
%GDOI-3-PSEUDO_TIME_LARGE : Pseudotime difference between KS ([dec] sec) and GM ([dec] sec) is larger than expected in group [chars]. Adjust to new PST |
|
---|---|
Explanation
|
A Group member has received pseudotime which has large difference as compared to own pseudotime |
Recommended Action |
%GDOI-3-PSEUDO_TIME_TOO_OLD : Rekey received in group [chars] is too old and fail PST check: my_pst is [dec] sec, peer_pst is [dec] sec, allowable_skew is [dec] sec |
|
---|---|
Explanation | A Group member has received pseudotime which has large difference as compared to own pseudotime |
Recommended Action |
%GDOI-3-GM_INCOMPLETE_CFG : Registration: incomplete config for group [chars] | |
---|---|
Explanation | Registration can not be completed since the GDOI group configuration may be missing the group id, server id, or both |
Recommended Action | Contact the Group member’s administrator. |
%GDOI-1-KS_NO_RSA_KEYS : RSA Key — [chars] : Not found, Required for group [chars] | |
---|---|
Explanation | Rsa Keys were not found in Key Server and they are required for signing and verifying rekey messages |
Recommended Action | Contact the Key Server’s administrator and ask him to do create the RSA Key pair |
%GDOI-4-RSA_KEYS_MODIFIED : WARNING: GMs for group [chars] will re-register due to signature verification failure | |
---|---|
Explanation | Rekeys will be dropped by GM as signature verification would fail due to modification of RSA Keys |
Recommended Action | Informational message |
%GDOI-3-KS_REKEY_AUTH_KEY_LENGTH_INSUFFICIENT : Rejected [chars] change: using sig-hash algorithm [chars] requires an authentication key length of at least [int] bits ([int] blocks in bytes) — [chars] [chars] key [chars] is only [int] blocks in bytes |
|
---|---|
Explanation
|
Using a sig-hash algorithm for rekeys requires that the RSA key modulus length for the rekey authentication be at least the length of the hash generated by the sig-hash algorithm plus some padding bytes. If the RSA key modulus length is not large enough, the Key Server administrator needs to generate a new RSA key pair wit a sufficient length. |
Recommended Action | Contact the Key Server’s administrator to re-generate the RSA key pair with at least the modulus length given in the syslog. |
%GDOI-3-COOP_CONFIG_MISMATCH : WARNING: Group [chars], [chars] configuration between Primary KS and Secondary KS are mismatched | |
---|---|
Explanation | The configuration between Primary KS and Secondary KS are mismatched |
Recommended Action | Contact the Key Sever’s administrator |
%GDOI-3-GM_ACL_PERMIT : GM doesn’t support permit configured under local access-list. Traffic from [chars] to [chars] will be dropped. |
|
---|---|
Explanation | GM can only support ACL for deny. Any traffic matching the permit entry will be dropped. |
Recommended Action | Remove the permit entry from the ACL used by GDOI crypto map |
%GDOI-3-GM_NO_IPSEC_FLOWS : IPSec FLOW limit possibly reached | |
---|---|
Explanation | Hardware Limitation for IPSec Flow limit Reached. Cannot create any more IPSec SAs |
Recommended Action | Contact the Group member’s administrator. |
%GDOI-3-GM_NO_CRYPTO_ENGINE : No crypto engine is found due to lack of resource or unsupported feature requested | |
---|---|
Explanation | Failed to select a suitable crypto engine because requested packet path not available, or requested feature not supported |
Recommended Action | Check policy configured on KS |
%GDOI-3-COOP_PACKET_DROPPED : Announcement message dropped due to packet size [dec] bytes. | |
---|---|
Explanation
|
Hard limit set on the driver buffer size prevents sending packets of this size or bigger |
Recommended Action | Informational message |
%GDOI-3-UNEXPECTED_SIGKEY : Unexpected Signature Key detected: freeing it | |
---|---|
Explanation | Unexpected Signature Key found: freeing the signature key |
Recommended Action | Informational message |
%GDOI-3-UNSUPPORTED_TEK_PROTO : Unexpected TEK Protocol : [dec] | |
---|---|
Explanation | Unexpected TEK PROTOCOL |
Recommended Action | Informational message |
%GDOI-4-GM_DELETE : GM [chars] deleted from group [chars]. | |
---|---|
Explanation | A group member has been deleted in a group from Key Server |
Recommended Action | Informational message |
%GDOI-5-KS_USING_DEFAULT_TRANSFORM : GETVPN is using default transforms for profile [chars] | |
---|---|
Explanation | Using default transformset |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-GM_REKEY_CIPHER_HASH_CHECK_FAIL : Rekey cipher/hash ([chars]) used in Group [chars] is unacceptable by this client. | |
---|---|
Explanation
|
The key-server has chosen KEK rekey cipher/hash algorithms which are not acceptable by this group-member |
Recommended Action | Contact the Key server’s administrator. |
%GDOI-5-GM_REKEY_TRANSFORMSET_CHECK_FAIL : The transformset ([chars]) for data-protection in Group [chars] is unacceptable by this client. |
|
---|---|
Explanation | The key-server has chosen a TEK transformset which is not acceptable by this group-member |
Recommended Action | Contact the Key server’s administrator. |
%GDOI-3-COOP_ANN_SEQ_FAILURE : COOP Ann msg seq check failed for group [chars], ann seq# [int], sess seq# [int] | |
---|---|
Explanation | COOP Ann msg seq check failed |
Recommended Action | Contact Administrator |
%GDOI-4-GDOI_ANN_TIMESTAMP_TOO_OLD : COOP_KS ANN from KS [chars] in group [chars] is too old and fail PST check: my_pst is [int] sec, peer_pst is [int] sec, allowable_skew is [dec] sec |
|
---|---|
Explanation | The KS has received an ANN msg from a primary KS in which the timestamp is too old |
Recommended Action |
%GDOI-4-GDOI_ANN_TIMESTAMP_LARGE : COOP_KS ANN received from KS [chars] in group [chars] has PST bigger than myself. Adjust to new PST: my_old_pst is [int] sec, peer_pst is [int] sec |
|
---|---|
Explanation | The KS receive an ANN from a KS in which the timestamp is bigger than expected; also update my PST to peer’s |
Recommended Action |
%GDOI-4-GDOI_ANN_TIMESTAMP_LARGE_NO_UPDATE : COOP_KS ANN received from KS [chars] in group [chars] has PST bigger than myself: my_pst is [int] sec, peer_pst is [int] sec |
|
---|---|
Explanation
|
The KS receive an ANN from a KS in which the timestamp is bigger than expected; No update of my PST |
Recommended Action |
%GDOI-4-GDOI_ANN_INCONSISTENT_TBAR : COOP_KS ANN received from [chars] in group [chars] has inconsistent TBAR setting inconsistent than mine |
|
---|---|
Explanation | The KS has received an ANN msg from a secondary KS in which the timestamp is too old |
Recommended Action |
%GDOI-5-COOP_KS_VALID_ANN_TIMER_EXPIRED : This sec-KS has NOT received an ANN with valid PST for an extended period in group [chars]. It will block new GMs registration temporarily until a valid ANN is received |
|
---|---|
Explanation | No valid ANN message has been received in this secondary KS for a prolong period. Temporarily blocking new GM registrations until a valid ANN is received |
Recommended Action | Informational message |
%GDOI-5-COOP_KS_BLOCK_NEW_GM_REGISTER_ANN : This KS temporarily blocks GM with ip-addr [chars] from registering in group [chars] as it has not received an ANN with valid PST for prolonged period |
|
---|---|
Explanation | No valid ANN message has been received in this secondary KS for a prolong period. Temporarily blocking new GM registrations until a valid ANN is received |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-COOP_KS_BLOCK_NEW_GM_REGISTER_ELECTION : This KS temporarily blocks GM with ip-addr [chars] from registering in group [chars] as the KS election is underway |
|
---|---|
Explanation | The KS is in the process of electing a primary. Temporarily blocking new GM registrations until the election is complete |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-COOP_KS_BLOCK_NEW_GM_REGISTER_KSSID : This KS is blocking GM with ip-addr [chars] from registering in group [chars] as it has overlapping KS Sender Identifier(s) (KSSID) with another COOP-KS peer (MISCONFIG) |
|
---|---|
Explanation
|
Another COOP-KS peer in the group has been configured with a KSSID value that is the same as one configured on this KS. GM registration is blocked as a result until the overlap is fixed. |
Recommended Action | Check the configured KSSID(s) for all COOP-KS peers by issuing ‘show crypto gdoi ks coop ident detail’ on the primary KS |
%GDOI-5-COOP_KS_RESUME_NEW_GM_REGISTER : This KS will now resume new GM registration functionality in group [chars] | |
---|---|
Explanation | This KS will now resume new GM registration functionality |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-SA_KEK_UPDATED : SA KEK was updated [hex][hex][hex][hex] | |
---|---|
Explanation | KEK was updated in the Registration/Rekey and a new KEK SA was created |
Recommended Action | Informational message. |
%GDOI-5-SA_PIP_UPDATED : SA PIP was updated 0x[chars] | |
---|---|
Explanation | PIP was updated in Registration/Rekey and a new PIP SA was created |
Recommended Action | Informational message. |
%GDOI-3-SA_KEK_INSATALL_FAILED : Failed to install KEK SA | |
---|---|
Explanation | KEK SA instalation has failed |
Recommended Action | Informational message. |
%GDOI-3-P2P_PEER_MIGRATE_FAILED : Failed to install P2P rekey SA with peer [chars] in group [chars] | |
---|---|
Explanation
|
Installation of P2P Rekey SA with an existing peer has failed |
Recommended Action | Check the status of all peers using the command ‘show crypto gdoi gm p2p peers’ and wait for PIP initiation between the failed peers. Traffic distruption may occur. |
%GDOI-5-SA_TEK_UPDATED : SA TEK was updated | |
---|---|
Explanation | TEK was updated in the Registration/Rekey and a new TEK IPSEC SA was created |
Recommended Action | Informational message. |
%GDOI-4-GM_MINOR_VERSION_MISMATCH : GM [IP_address] Minor Version mismatch. Use ‘show crypto gdoi ks members’ to see GM versions | |
---|---|
Explanation | GM has different minor version. |
Recommended Action | show crypto gdoi ks members |
%GDOI-3-GM_MAJOR_VERSION_MISMATCH : GM [IP_address] registration rejected due to major version mismatch. GM must be using major version [dec] in order to be compatible with this KS |
|
---|---|
Explanation | GM has a non-compatible major version. |
Recommended Action | Check GDOI version compatibility on KS and GMs |
%GDOI-4-KS_MINOR_VERSION_MISMATCH : COOP-KS Minor Version mistmatch in group [chars]. My version is [dec].[dec].[dec], peer [chars] has version [dec].[dec].[dec] |
|
---|---|
Explanation | Coop KS has different minor version. |
Recommended Action | show crypto gdoi ks coop |
%GDOI-3-KS_MAJOR_VERSION_MISMATCH : COOP-KS Major Version mismatch in group [chars]. My version is [dec].[dec].[dec], peer [chars] has version [dec].[dec].[dec] |
|
---|---|
Explanation
|
COOP-KS has a non-compatible major version. |
Recommended Action | Check GDOI version compatibility on KS |
%GDOI-2-COOP_MINOR_VERSION_MISMATCH : COOP-KS Minor version mistmatch in group [chars]. My COOP version is [dec].[dec].[dec], peer [chars] has version [dec].[dec].[dec]. Upgrade [chars] [chars] to COOP version [dec].[dec].[dec] to prevent COOP outage. |
|
---|---|
Explanation | Coop KS has different minor version. |
Recommended Action | show crypto gdoi ks coop |
%GDOI-3-COOP_MAJOR_VERSION_MISMATCH : COOP-KS Major Version mismatch in group [chars]. My version is [dec].[dec].[dec], peer [chars] has version [dec].[dec].[dec] |
|
---|---|
Explanation | COOP-KS has a non-compatible major version. |
Recommended Action | Check COOP version compatibility on KS |
%GDOI-3-COOP_LIMIT_REACHED : Peer [chars] has reached COOP limit of maximum number of gms. COOP GM database sync fails. Upgrade to COOP version [dec].[dec].[dec] and above |
|
---|---|
Explanation | COOP-KS has a non-compatible peer. |
Recommended Action | Check COOP version compatibility on peer KS |
%GDOI-5-POLICY_CHANGE : GDOI group [chars] policy has changed. Use ‘crypto gdoi ks rekey’ to send a rekey, or the changes will be send in the next scheduled rekey |
|
---|---|
Explanation | Reminder message that GDOI configuration has changed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-ESON_POLICY_CHANGE_RESTART1 : ESON group [chars] policy has changed. Must use ‘clear crypto gdoi ks members now’ to restart the group |
|
---|---|
Explanation
|
Reminder message that ESON configuration has changed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-ESON_POLICY_CHANGE_RESTART2 : ESON group [chars] policy has changed. Must use ‘crypto gdoi ks replace now’ to restart the group |
|
---|---|
Explanation | Reminder message that ESON configuration has changed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-GM_DELETE_EXPIRED_KEK : KEK expired for group [chars] and was deleted | |
---|---|
Explanation | Deleting Expired KEK |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-GM_DELETE_EXPIRED_PIP : PIP with SPI 0x[chars] expired for group [chars] and was deleted | |
---|---|
Explanation | Deleting Expired PIP |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-GM_DELETE_EXPIRED_P2P : P2P SA with epoch hash 0x[chars] expired for group [chars] and was deleted | |
---|---|
Explanation | Deleting Expired P2P |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-POLICY_CHANGE_TO_SUITEB : Group [chars] changed to Suite-B policy. Use ‘crypto gdoi ks rekey’ to generate the new Suite-B policy and cause all GMs to re-register to download SIDs, or this will happen in the next scheduled rekey |
|
---|---|
Explanation | Migrating from non-Suite-B to Suite-B policy requires that the user issues ‘crypto gdoi ks rekey’ like any other POLICY_CHANGE, but this will cause a re-initialization rather than just a rekey. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-KS_REINIT_GROUP : [chars] for group [chars] and will re-initialize the group. | |
---|---|
Explanation | KS has reached one of the following conditions (indicated by the first part of the message) requiring re-initialization of the group: — Group Size configuration changed — Previously used KSSID removed from configured KSSID set — KS runs out of KSSIDs & GMSIDs — COOP SID client gets a re-initialization indication from COOP-KS — KSSID overlap detected by COOP is resolved — TEK policy is changed from non-CTR to CTR (SIDs required). |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-KS_REINIT_FINISH : Re-initialization of group [chars] completed. | |
---|---|
Explanation | A previously triggered re-initialization, as signified by a %GDOI-5-KS_REINIT_GROUP syslog, has completed after the expiry of the old TEK. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-3-KS_NO_SID_AVAILABLE : GMs for group [chars] need SIDs but this KS has no KS SIDs configured or no more SIDs available. | |
---|---|
Explanation | This KS has a counter-mode transform configured requiring SIDs and either has no KSSIDs configured or has run out of SIDs. Registering GMs will not be able to register successfully until more KSSIDs are configured on this KS. |
Recommended Action | Check the configured KSSID(s) for this KS by issuing ‘show crypto gdoi ks ident detail’ and consider configuring more KSSIDs using the ‘identifier’ sub-mode under ‘server local’. |
%GDOI-3-COOP_KSSID_OVERLAP : Overlapping KS Sender Identifier(s) (KSSID) {[chars]} with COOP-KS peer [chars] in group [chars] blocking GM registration (MISCONFIG) |
|
---|---|
Explanation | Another COOP-KS peer in the group has been configured with a KSSID value that is the same as one configured on this KS. GM registration is blocked as a result until the overlap is fixed. |
Recommended Action | Check the configured KSSID(s) for all COOP-KS peers by issuing ‘show crypto gdoi ks coop ident detail’ on the primary KS |
%GDOI-5-COOP_KSSID_OVERLAP_RESOLVED : Resolved overlapping KS Sender Identifier(s) (KSSID) with COOP-KS peer allowing GM registrations once again |
|
---|---|
Explanation | Another COOP-KS peer in the group had been configured with a KSSID value that was the same as one configured on this KS, but has been resolved so that GM registration is allowed again. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-GM_IV_EXHAUSTED : GM for group [chars] exhausted its IV space for interface [chars] and will re-register. | |
---|---|
Explanation | One of the interfaces where a CTR transform (e.g. GCM-AES / GMAC-AES) has been installed as TEK policy with SIDs has exhausted its IV space & must re-register to receive new SIDs. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-GM_REKEY_IPV4_POLICY_CHECK_FAIL : Non-IPv4 policies is received in IPv4 Group [chars]; rekey is rejected | |
---|---|
Explanation | This GM is registering to an IPv4 group but erroneously receiving IPv6 policies in rekey |
Recommended Action | Contact the Key server’s administrator. |
%GDOI-5-GM_REKEY_IPV6_POLICY_CHECK_FAIL : Non-IPv6 policies is received in IPv6 Group [chars]; rekey is rejected | |
---|---|
Explanation | This GM is registering to an IPv6 group but erroneously receiving IPv4 policies in rekey |
Recommended Action | Contact the Key server’s administrator. |
%GDOI-4-UNKNOWN_GM_VERSION_REGISTER : WARNING: GM [IP_address] with unknown GDOI ver registered to group [chars] (e.g old-IOS or non-Cisco GM please check ‘show crypto gdoi ks members’ and ‘show crypto gdoi feature’ to ensure all your GMs can support the GETVPN features enabled. |
|
---|---|
Explanation | A GM is registered with unknown GDOI SW version; cannot determine its feature capability. |
Recommended Action | Check GMs can support all GETVPN features enabled in KS. Also check output of ‘show crypto gdoi feature’ and ‘debug crypto gdoi ks infra detail’ (note: high volume of debugs). msgdef_ddts_component(ipsec-getvpn) |
%GDOI-4-NEWER_GM_VERSION_REGISTER : WARNING: GM [IP_address] registers to group [chars] with newer GDOI version than KS. Please check’show crypto gdoi ks members’ and ‘show crypto gdoi feature’ to ensure all GMs can support the GETVPN features enabled. |
|
---|---|
Explanation | A GM is registered with newer GDOI SW version; cannot determine its feature capability. |
Recommended Action | Check GMs can support all GETVPN features enabled in KS. Also check output of ‘show crypto gdoi feature’ and ‘debug crypto gdoi ks infra detail’ (note: high volume of debugs). msgdef_ddts_component(ipsec-getvpn) |
%GDOI-4-REJECT_GM_VERSION_REGISTER : Reject registration of GM [IP_address] (ver [hex]) in group [chars] as it cannot support these GETVPN features enabled: [chars] |
|
---|---|
Explanation | Reject GM registration because it cannot support the GETVPN features enabled in the group. |
Recommended Action | Check GMs can support all GETVPN features enabled in KS. Also check output of ‘show crypto gdoi feature’ and ‘debug crypto gdoi ks infra detail’ (note: high volume of debugs). msgdef_ddts_component(ipsec-getvpn) |
%GDOI-4-GM_RECOVERY_REGISTRATION : GM recovery re-registration for group [chars] will start in a randomly chosen period of [dec] sec |
|
---|---|
Explanation | GM recovery feature detects dataplane error and will re-register to KS to refresh keys and policy |
Recommended Action | Informational message. |
%GDOI-4-GM_RECOVERY_REGISTRATION_POSTPONED : Detects data error in group [chars] but the previous recovery/rekey has occured within the last recovery-check interval. Postpone recovery registration to start in [dec] sec |
|
---|---|
Explanation | GM recovery feature detects dataplane error and will re-register to KS to refresh keys and policy |
Recommended Action | Informational message. |
%GDOI-4-GM_SA_TRACK_SET_EOT_ERROR : Group [chars] encountered error in setting EOT object ID [dec] to state [chars]. | |
---|---|
Explanation | GM SA TRACK state change occur but fail to update EOT object ID accordingly |
Recommended Action | Informational message. Check to make sure the EOT object ID is configured properly |
%GDOI-5-POLICY_CHANGE_ERROR_MULTIPLE_PORTS : Multiple ports detected for ACL [chars] which is not supported. WARNING: No TEK policy will be created. |
|
---|---|
Explanation | Informs user that there is an error in the ACL with regards to the number of ports. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-6-COOP_KS_VER_TRANSIT : Coop KS [chars] protocol version transits from version 1.0.1 to 2.0.0 | |
---|---|
Explanation | The KS is transitioning to a new version. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-4-COOP_KS_RBLY_FAILED : Coop KS [chars] in group [chars] session Reassembly failed in TransID [int] | |
---|---|
Explanation | The KS COOP had an error reassmbling a packet from a peer KS |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-4-COOP_KS_CHECKPT_MISMATCH : Coop KS [chars] in group [chars] received Checkpoint Mismatch message. | |
---|---|
Explanation | The KS COOP had received a checkpoint mismatch from a KS COOP peer |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-3-COOP_KS_CANNOT_FIND_PROFILE : Coop KS in group [chars] has a configured IKEv2 profile ‘[chars]’ that doesn’t exist. The COOP will not come up until this error is fixed. |
|
---|---|
Explanation | The KS COOP coniguration redunadancy ikve2-profile specifies a profile that doesn’t exist. The COOP will not come up. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-IPSEC_INITIATE_GM_REGISTER : IPSEC initiate GDOI group [chars] to register | |
---|---|
Explanation | IPSEC initiate a GM registration for the group |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-3-IPSEC_INITIATE_GM_REGISTER_POSTPONE : IPSEC triggering registration for group [chars] too frequently. Postpone the registration to occur in [dec] msec. |
|
---|---|
Explanation | GM detects IPSEC triggering registration for the group too frequently. GDOI will rate-limit and postpone the registration. |
Recommended Action | Contact the Group member’s administrator. |
%GDOI-3-IPSEC_INITIATE_GM_REGISTER_IGNORE : IPSEC triggering registration for group [chars] too frequently. Ignore the request as registartion has already been scheduled to occur in [dec] msec. |
|
---|---|
Explanation | GM detects IPSEC triggering registration for the group too frequently. GDOI will ignore the request as registration has already been scheduled. |
Recommended Action | Contact the Group member’s administrator. |
%GDOI-3-COOP_KS_TOO_MANY_GROUPS_SHARE_IKE_SA : The COOP KS has too many groups sharing the same IKE SA for the peer addresses local [chars] remote [chars]. Connectivity could be compromised. Please reduce to [dec]. |
|
---|---|
Explanation | There is a limit to the number of COOP KS groups that can share the. same IKE SA. This can lead to intermittent connectivity for the COOP KS in congested networks |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-3-COOP_KS_SEND_WINDOW_LIMIT_REACHED : The COOP KS has reached its window limit for the peer addresses local [chars] remote [chars]. This is due to connectivity issues between the key servers in question. |
|
---|---|
Explanation | The COOP KS running over IKEv2 has a limit to the number of pending messages that can be sent. This limit has been reached which is an indication that there is a connectivity issue between the key servers |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-4-REJECT_GM_CKM_REGISTER : Reject registration of GM [IP_address] in group [chars] as it has CKM enabled but this secondaryKS has not sync up all KGS params yet |
|
---|---|
Explanation | Reject GM registration because this is a secondaryKS and it has not received KGS seed and rekey-epoch from primaryKS yet |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-4-COOP_KS_CKM_INCOMPATIBLE : Found incompatible COOP-KS that cannot support CKM in group [chars]. Please check ‘show crypto gdoi feature ckm’and upgrade the incompatible KS immediately. |
|
---|---|
Explanation | Found incompatible COOP-KS that cannot support CKM in the group. Network administrator should check ‘show crypto gdoi feature ckm’and upgrade the incompatible KS immediately |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-5-GM_REGISTER_UPDATE_TBAR : Platform HA forwarding-plane comes online, group [chars] gm-identity [chars] fvrf [chars] ivrf [chars] re-register to refresh TBAR info. |
|
---|---|
Explanation | HA forwarding-plane comes online, group %s gm-identity %s fvrf %s ivrf %s is re-registering to refresh TBAR info. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GDOI-3-GM_IPD3P_NO_IPV6_SUPPORT : GETVPN group-member does not support IP-D3P for IPv6. | |
---|---|
Explanation | GETVPN group-member does not support IP-D3P for IPv6. |
Recommended Action | Contact the Administrator(s) to correct the key server policy. |
%GDOI-3-GM_IPD3P_NO_TRANSPORT_SUPPORT : GETVPN group-member does not support IPD3P transport mode | |
---|---|
Explanation | GETVPN group-member does not support IPD3P transport mode |
Recommended Action | Contact the Administrator(s) to correct the key server policy. |
%GDOI-3-GM_IPD3P_AND_CMD_CANT_COEXIST : GETVPN group-member does not support coexistance of IPD3P and Cisco-metadata features | |
---|---|
Explanation | GETVPN group-member does not support the enabling of IPD3P and Cisco-metadata features (e.g TBAR-PST, SGT) at the time |
Recommended Action | Contact the Administrator(s) to correct the key server policy. |
GENERIC_SUBBLOCK
%GENERIC_SUBBLOCK-2-LATE_REGISTER : Late registration of GSB type [chars], with id [dec] | |
---|---|
Explanation | An attempt to register a new generic subblock type was received after subblocks have already been allocated from the control structure with previously registered types |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GENERIC_SUBBLOCK-2-BUILDXDR : Failed to build message for GSB: [chars] | |
---|---|
Explanation | An attempt to build a message for distribution of generic subblock failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GENERIC_SUBBLOCK-2-UNPACKXDR : Unpacked [dec] bytes and attempted to consume [dec] bytes for GSB: [chars] | |
---|---|
Explanation | A discrepancy was detected between length of message expected versus length of message received |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GENERIC_SUBBLOCK-2-GSBNOTISSUAWARE : GSB [chars] is not ISSU aware. Cannot distribute it to ISSU-aware slots | |
---|---|
Explanation | This GSB is expected to be ISSU aware but it is not. It cannot be distributed safely to ISSU-aware slots as it may not be correctly interpreted |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
GEN_DB
%GEN_DB-3-NULL_TREE_NODE : Node is NULL [chars] | |
---|---|
Explanation | This message indicates that the tree node being examined is NULL |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%GEN_DB-3-INVALID_RECORD_KEY : [chars]: invalid record key * | |
---|---|
Explanation | This message indicates that the record key is invalid |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%GEN_DB-3-NO_KEY_FUNC : [chars]: [chars][chars] | |
---|---|
Explanation | This message indicates that key functions are missing from the database handle, or key function is a NULL Pointer |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%GEN_DB-3-KEY_FUNC_DOESNT_EXIST : [chars]: Key function does not exist | |
---|---|
Explanation | This message indicates that key function being considered does not exist in the database definition |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%GEN_DB-3-INVALID_CLIENT_TYPE : [chars]: Invalid client type, got [dec] (must be between 0 and [dec]) | |
---|---|
Explanation | This message indicates that client type is outside the expected range |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%GEN_DB-3-NULL_DB_HNDL : NULL Database Handle [chars] | |
---|---|
Explanation | This message indicates the database handle was NULL |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%GEN_DB-3-NULL_DB_HNDL_ELEMENT : [chars]: NULL Database Element [chars] | |
---|---|
Explanation | This message indicates the database handle element was NULL |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%GEN_DB-3-LIST_FAIL : [chars]:[chars] | |
---|---|
Explanation | This message indicates that a list operations such as enqueue, dequeu failed |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%GEN_DB-3-LIST_FAIL_FOR_RECORD : [chars]:[dec]:[chars] | |
---|---|
Explanation | This message indicates that a list operations such as enqueue, dequeu failed |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%GEN_DB-3-WAVL_FAIL : [chars]: [chars] | |
---|---|
Explanation | This message indicates that a wavl tree operation failed |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%GEN_DB-3-RECORD_DELETE_FAIL : [chars]:[chars] | |
---|---|
Explanation | This message indicates that a record could not be deleted |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%GEN_DB-3-PARSER_INIT_FAIL : [chars]:[dec]: Parser Could not be initialized | |
---|---|
Explanation | This message indicates that the IOS Parser command could not be initialized |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%GEN_DB-3-UNKNOWN_PARSER_CMD : [chars]:[dec]: Unknown Parser Command | |
---|---|
Explanation | This message indicates that the IOS Parser command was not recognized |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
GEN_PROXY
%GEN_PROXY-3-IPC_UNHANDLED : failure | |
---|---|
Explanation | An unknown message type: %d was received by the Generic Client Proxy. |
Recommended Action | LOG_STD_ACTION |
%GEN_PROXY-3-REPLY_MSG : wrong version [dec] | |
---|---|
Explanation | An incorrect SBS message was received by the Generic Client Proxy. |
Recommended Action | LOG_STD_ACTION |
%GEN_PROXY-3-STACK_ALLOC_FAILED : Stack allocation for reply failed reply_size [hex] | |
---|---|
Explanation | Stack space could not be allocated for reply. |
Recommended Action | LOG_STD_ACTION |
%GEN_PROXY-3-GPM_ALLOC_FAILED : GPM allocation for reply failed pak_size [hex] reply_size [hex] | |
---|---|
Explanation | GPM could not be allocated for reply. |
Recommended Action | LOG_STD_ACTION |
%GEN_PROXY-3-IPC_SEND_FAILED : IPC send reply failed [chars] | |
---|---|
Explanation | GEN proxy failed to send of reply to IPC msg. |
Recommended Action | LOG_STD_ACTION |
GLBP
%GLBP-4-BADAUTH : Bad authentication received from [chars], group [dec] | |
---|---|
Explanation | Two routers participating in a Gateway Load Balancing Protocol group disagree on the valid authentication string. |
Recommended Action | Use the glbp authentication interface command to repair the GLBP authentication discrepancy between the local system and the one whose IP address is reported. |
%GLBP-3-MISCONFIG : Cannot add MAC address [enet] to interface [chars] — not supported | |
---|---|
Explanation | A software or hardware error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%GLBP-6-STATECHANGE : [chars] Grp [int] state [chars] -> [chars] | |
---|---|
Explanation | The GLBP gateway has changed state |
Recommended Action | No action is required. |
%GLBP-6-FWDSTATECHANGE : [chars] Grp [int] Fwd [int] state [chars] -> [chars] | |
---|---|
Explanation | The GLBP forwarder has changed state |
Recommended Action | No action is required. |
%GLBP-4-DUPADDR : Duplicate address [chars] on [chars], sourced by [enet] | |
---|---|
Explanation | The IP address in a GLBP message received on the interface is the same as the router’s own IP address. This may be because of misconfiugration, or because of a malfunctioning switch |
Recommended Action | Check the configurations on all the GLBP routers, and make sure that any switches you have are functioning properly. |
%GLBP-4-DUPVIP1 : [chars] Grp [dec] address [chars] is already assigned to [chars] group [dec] | |
---|---|
Explanation | The GLBP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to a different GLBP group. |
Recommended Action | Check the configuration on all GLBP routers. |
%GLBP-4-DUPVIP2 : [chars] Grp [dec] address [chars] is already assigned on this interface | |
---|---|
Explanation | The GLBP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to this interface. |
Recommended Action | Check the configuration on all GLBP routers. |
%GLBP-4-DUPVIP3 : [chars] Grp [dec] address [chars] is already assigned to, or overlaps with, an address on another interface or application |
|
---|---|
Explanation | The GLBP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to, or overlaps with, an address on another interface or application. |
Recommended Action | Check the configuration on all GLBP routers. |
%GLBP-4-BADVIP : [chars] Grp [dec] address [chars] is in the wrong subnet for this interface | |
---|---|
Explanation | The GLBP virtual IP address contained in the Hello message cannot be learnt as it is not within a subnet configured on the interface. |
Recommended Action | Check the configuration on all GLBP routers and ensure that the virtual IP address is within a configured subnet. |
%GLBP-4-DIFFVIP1 : [chars] Grp [dec] active routers virtual IP address [chars] is different to the locally configured address [chars] |
|
---|---|
Explanation | The GLBP virtual IP address contained in the Hello message from the Active router is different to that configured locally. |
Recommended Action | Check the configuration on all GLBP routers. |
GRIP
%GRIP-3-BADPATHS : Invalid number of paths ([dec]) for %q | |
---|---|
Explanation | An internal inconsistency was detected in the XNS routing table structure. |
Recommended Action | Note the parameters associated with this message and call your technical support representative for assistance. |
%GRIP-2-BADROUTE : Error [chars] route — null table | |
---|---|
Explanation | A hardware or software error occurred. |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
HA
%HA-6-TOOBIG : Running config too big, config sync failed | |
---|---|
Explanation | The running config was too big to be synced |
Recommended Action | No action is required. |
%HA-6-SWITCHOVER : Route Processor switched from standby to being active | |
---|---|
Explanation | This RP switched to become the active RP |
Recommended Action | No action is required. |
HAL_GENMEM
%HAL_GENMEM-3-HAL_MISMATCHED_GENMEM : VADDR:[int] LINE: [dec] | |
---|---|
Explanation | Mismatched genmem. |
Recommended Action | LOG_STD_ACTION |
HAL_PACKET through HTSP
-
HAL_PACKET
-
HA_EM
-
HA_PROXY
-
HDLC
-
HFSLIB
-
HMAN
-
HMAN_CPU
-
HPI
-
HSRP
-
HTSP
HAL_PACKET
%HAL_PACKET-3-HAL_GATHER_ASYNC_WAIT_TIMEOUT : seqnum=[int] pak-type=[int] | |
---|---|
Explanation | Packet Hardware Transmit Error |
Recommended Action | LOG_STD_ACTION |
HA_EM
%HA_EM-7-FMCMN_PTHREAD_MUTEX_LOCK : [chars]: Error locking mutex [chars]; [chars] | |
---|---|
Explanation | The pthread_mutex_lock function reported an error while attempting to lock the specified mutex. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMCMN_PTHREAD_MUTEX_UNLOCK : [chars]: Error unlocking mutex [chars]; [chars] | |
---|---|
Explanation | The pthread_mutex_unlock function reported an error while attempting to unlock the specified mutex. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFDCMN_DM_CREATE : [chars]: could not create dispatch manager: [chars] | |
---|---|
Explanation | The event detector has failed to create an dispatch manager. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFDCMN_EA_ATTACH : [chars]: could not register for asynchronous message events: [chars] | |
---|---|
Explanation | The event detector has failed to attach an event handler for asynchronous messages. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFDCMN_INV_TM : [chars]: invalid timer: type=[dec], timer=[IPV6 address] | |
---|---|
Explanation | Internal error. The timer value is invalid or not as expected. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFDCMN_INV_TM_TYPE : [chars]: invalid timer type: [dec] | |
---|---|
Explanation | Internal error. The timer type is invalid or not supported. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFDCMN_MSGSEND_EVT : [chars]: error returned from event_send_pulse; [chars] | |
---|---|
Explanation | The event detector has failed to send a pulse to itself to notify of a pending message send event. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFDCMN_PUB_RBLD : [chars]: [chars] | |
---|---|
Explanation | Internal error. The event detector has failed to rebuild the publish list from the checkpointed records. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFDCMN_XDM_DISPATCH_FAIL : [chars]: XOS Dispatch Manager dispatch error: [dec] | |
---|---|
Explanation | XOS Dispatch Manager reports an error when dispatching an event. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFDCMN_XDM_WAIT_FAIL : [chars]: XOS Dispatch Manager wait error: [dec] | |
---|---|
Explanation | XOS Dispatch Manager reports an error when waiting for an event. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_ADD_PARSER : [chars]: Unable to add [chars] event detector command; | |
---|---|
Explanation | The Event detector failed to add command. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_CHKPT_INIT : [chars]: [chars] | |
---|---|
Explanation | Internal error. The event detector has failed to initialize with the checkpointing server. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_CHKPT_TBL_ADD : [chars]: [chars] | |
---|---|
Explanation | Internal error. The event detector has failed to add a record to the checkpointing table. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_CHKPT_TBL_INIT : [chars]: [chars] | |
---|---|
Explanation | Internal error. The event detector has failed to initialize a table with the checkpointing server. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_CHKPT_TBL_ITERATE : [chars]: [chars] | |
---|---|
Explanation | Internal error. The event detector has failed to iterate the checkpointing table. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_CHKPT_TBL_REMOVE : [chars]: [chars] | |
---|---|
Explanation | Internal error. The event detector has failed to remove a record from the checkpointing table. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_COND_WAIT : [chars]: conditional wait error: [chars] | |
---|---|
Explanation | Internal error. The event detector has failed to do pthread conditional wait. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_CONNECTION_FAIL : Could not connect to [chars] : [chars] | |
---|---|
Explanation | Could not connect to event detector on the remote node. Node may be invalid or not available or the process may not be available to accept the connection. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_DE_FETCH : [chars]: [chars][[dec]] | |
---|---|
Explanation | Internal error. The event detector has failed to fetch a data elementfrom the statistics data engine. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_DE_INIT : [chars]: [chars] | |
---|---|
Explanation | Internal error. The event detector has failed to initialize the statistics data engine. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_DM_CREATE : [chars]: could not create dispatch manager: [chars] | |
---|---|
Explanation | The event detector has failed to create an dispatch manager. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_EA_ATTACH : [chars]: could not register for asynchronous message events: [chars] | |
---|---|
Explanation | The event detector has failed to attach an event handler for asynchronous messages. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMFD_EMPTY_QUEUE : [chars]: The [chars] event detector I/O queue empty. | |
---|---|
Explanation | The I/O queue is empty at this point, and should not be. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_ENQUEUE_FAIL : [chars]: Unable to enqueue [chars]; | |
---|---|
Explanation | The enqueue function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_EV_BLOCK : [chars]: [chars] | |
---|---|
Explanation | The event_block function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_EVM_CREATE : Could not create event manager: [chars] | |
---|---|
Explanation | The event detector has failed to create an Event Manager. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_HIST_QERR : [chars] | |
---|---|
Explanation | Internal error. The event detector has failed to get a free history listentry. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_HIST_RBLD : [chars]: [chars] | |
---|---|
Explanation | Internal error. The event detector has failed to rebuild the history list from the checkpointed records. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_INV_COMPARE_OP : [chars]: invalid comparison operator: [dec] | |
---|---|
Explanation | Internal error. The value comparison operator is invalid or notsupported. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_INV_STATS_TYPE : [chars]: invalid statistics value type: [dec] | |
---|---|
Explanation | Internal error. The statistics data type is invalid or not supported. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_INV_TM : [chars]: invalid timer: type=[dec], timer=[IPV6 address] | |
---|---|
Explanation | Internal error. The timer value is invalid or not as expected. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_INV_TM_TYPE : [chars]: invalid timer type: [dec] | |
---|---|
Explanation | Internal error. The timer type is invalid or not supported. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_LOCAL_NODEID : Could not get local nodeid: [chars] | |
---|---|
Explanation | Could not get local node identifier. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_MALLOC : [chars]: Unable to allocate [chars]; [chars] | |
---|---|
Explanation | The malloc function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_MET_ENQUEUE : [chars]: could not enqueue metric data: [chars] | |
---|---|
Explanation | Internal error. The system manager event detector has failed to add a metric data entry to the list. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_MET_RBLD : [chars]: [chars] | |
---|---|
Explanation | Internal error. The event detector has failed to rebuild the metriclist from the checkpointed records. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_MISC_ERR : [chars]: [chars] | |
---|---|
Explanation | An unexpected error occurred. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_MSGSEND_EVT : [chars]: error returned from event_send_pulse; [chars] | |
---|---|
Explanation | The event detector has failed to send a pulse to itself to notify of a pending message send event. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_MSGSEND_RETRY_ERR : [chars]: [dec] | |
---|---|
Explanation | The event detector has exceeded its maximum number of retries to send apulse to the embedded event manager to notify of an event publish. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_NO_CLOCK : [chars]: unable to read clock using clock_gettime: [chars] | |
---|---|
Explanation | The clock_gettime function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_NO_MEM : [chars]: not enough memory: [chars] | |
---|---|
Explanation | Allocating memory failed due to a low-memory condition. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_OE_CREATE : [chars]: could not create an occurrence entry | |
---|---|
Explanation | Internal error. The event detector has failed to create an entry for thematched occurrence list. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_OE_REMOVE : [chars]: could not remove an occurrence entry | |
---|---|
Explanation | Internal error. The event detector has failed to remove an entry for thematched occurrence list. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMFD_OID_UNAVAIL : [chars]: The following oid has become unavailable: [chars] | |
---|---|
Explanation | The registered oid is no longer available in the system. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_OPEN_CONF : [chars]: could not open event detector config file: [chars] | |
---|---|
Explanation | The event detector has failed to open the config file for event detector type information. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_PTHRD_CREATE : [chars]: could not create a Posix thread | |
---|---|
Explanation | The pthread_create function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_PUB_RBLD : [chars]: [chars] | |
---|---|
Explanation | Internal error. The event detector has failed to rebuild the publish list from the checkpointed records. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_PUB_TM_ALLOC : [chars]: Unable to allocate memory for event publish timer block | |
---|---|
Explanation | Internal error. The event detector has failed to allocate memoryfor the event publish timer block. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMFD_QUEUE_INIT : [chars]: Unable to initialize queue; | |
---|---|
Explanation | The queue initialization function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_RESOURCE_MONITOR_REGISTER_FAIL : [chars]: resource_monitor_register failed; return code = [dec] | |
---|---|
Explanation | The resource_monitor_register function reported an error trying toregister for RMI notifications. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_RM_ATTACH : [chars]: could not attach resource manager funtions to event manager: [chars] | |
---|---|
Explanation | The event detector has failed to attach a Resource Manager to an Event Manager. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SM_PROC_EXIT : [chars]: [chars] | |
---|---|
Explanation | The system manager failed to execute the default action of the terminated process. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SNMP_ADDR_ILLEGAL : [chars]: Illegal SNMP address type | |
---|---|
Explanation | The SNMP address is illegal. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SNMP_ADDR_IPV6 : [chars]: SNMP IPV6 address is not supported | |
---|---|
Explanation | The IPV6 address is not supported. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SNMP_BUILD_PDU_FAILED : [chars]: SNMP build pdu failed | |
---|---|
Explanation | The SNMP pdu build has failed. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SNMP_COMM_FAIL : [chars]: Unable to create SNMP octet community string; string = [chars] | |
---|---|
Explanation | The community string was not able to build into a SNMP octet string |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SNMP_COMMUNICATE_FAIL : [chars]: [chars] [chars] | |
---|---|
Explanation | Unable to communicate with SNMPD process |
Recommended Action | Check whether SNMP is configured on this Router. |
%HA_EM-7-FMFD_SNMP_ERRCODE : [chars]: [chars] | |
---|---|
Explanation | The SNMP error code. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SNMP_MAKE_PDU_FAILED : [chars]: SNMP make pdu failed | |
---|---|
Explanation | The SNMP pdu make has failed. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMFD_SNMP_MIB_OBJ_REP_FAIL : [chars]: SNMP MIB object info replace failed [dec] | |
---|---|
Explanation | The SNMP MIB object info replace function has failed. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SNMP_MSG_FAIL : [chars]: Unable to create a SNMP message; community = [chars] | |
---|---|
Explanation | The SNMP message failed to be created |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-4-FMFD_SNMP_NO_OBJECT_VALUE : [chars]: SNMP MIB object value not provided | |
---|---|
Explanation | The SNMP MIB object value is not provided for substitution. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMFD_SNMP_OBJECT_UNKNOWN_RESPONSE_CODE : [chars]: Unknown SNMP object response code [dec] | |
---|---|
Explanation | The SNMP MIB object response code is unknown. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SNMP_OID_INVALID : [chars]: Invalid SNMP oid length [dec] | |
---|---|
Explanation | The SNMP oid has invalid length |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SNMP_OID_MAKE_FAIL : [chars]: Unable to build an oid string into a SNMP oid; oid = [chars] | |
---|---|
Explanation | The oid string was not able to build into a SNMP oid |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SNMP_REQ_FAILED : [chars]: SNMP request failed | |
---|---|
Explanation | The SNMP request has failed. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SNMP_RESP_CANCEL : [chars]: SNMP response cancelled | |
---|---|
Explanation | The SNMP response has been cancelled. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SNMP_RESP_ERROR : [chars]: SNMP response error; error_status = [dec] | |
---|---|
Explanation | The SNMP response has error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SNMP_RESP_Q_EMPTY : [chars]: SNMP proxy exec got event, but queue is empty | |
---|---|
Explanation | The SNMP proxy got event but the queue is empty. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SNMP_RESP_TIMEOUT : [chars]: SNMP response has timed out | |
---|---|
Explanation | The SNMP response has timed out. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SNMP_UNKNOWN_TYPE : [chars]: Unknown SNMP operation or response type [dec] | |
---|---|
Explanation | The operation or response type is unknown. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SNMP_VARBIND_FAIL : [chars]: Unable to create a SNMP varbind | |
---|---|
Explanation | The oid failed to make into a SNMP varbind |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_STATS_VAL_GET_ERR : [chars]: [chars] | |
---|---|
Explanation | Internal error. The event detector has failed retrieving a valid statistics value. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SYSDB_BIND : [chars]: [chars] | |
---|---|
Explanation | Failed to bind to SysDB. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SYSDB_GET : [chars]: [chars] | |
---|---|
Explanation | Failed to retrieve an item from SysDB. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_SYSDB_REG_NOTIFY : [chars]: [chars] | |
---|---|
Explanation | Failed to register for notification of a set of items in SysDB. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_TM_CRTICK_INIT : [chars]: [chars] | |
---|---|
Explanation | Internal error. The initialization of the cron-tick function has failed. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_TM_LEAF_NEW : [chars]: could not create a leaf timer | |
---|---|
Explanation | Internal error. The event detector has failed to create a managedleaf timer. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMFD_TTY_NUM : [chars]: Error occurred while fetching TTY number. | |
---|---|
Explanation | The Embedded Event Manager failed to fetch a TTY number. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_XDM_DISPATCH_FAIL : [chars]: XOS Dispatch Manager dispatch error: [dec] | |
---|---|
Explanation | XOS Dispatch Manager reports an error when dispatching an event. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMFD_XDM_WAIT_FAIL : [chars]: XOS Dispatch Manager wait error: [dec] | |
---|---|
Explanation | XOS Dispatch Manager reports an error when waiting for an event. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMC_APPL_CBH_PULSE : [chars]: Unable to locate application publish callback entry for pulse code [dec] | |
---|---|
Explanation | The application publish callback handler was unable to validate the pulse code received. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMC_APPL_CBH_SEND : [chars]: Unable to send response for FH_MSG_CALLBACK_DONE [chars] | |
---|---|
Explanation | The registration callback handler was unable to send the FH_MSG_CALLBACK_DONE message to the Embedded Event Manager Server. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMC_CB_CLOSE : [chars]: fh_close failed [chars] | |
---|---|
Explanation | The fh_close function reported an error trying to initialize the internal callback connection. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMC_CB_EV_CREATE : [chars]: event_manager_create failed [chars] | |
---|---|
Explanation | The event_manager_create function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMC_CBH_PROCESS_CREATE : [chars]: callback handler process create failed for eid: [dec] | |
---|---|
Explanation | The process_create function reported an error trying to create thecallback handler process. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMC_CB_INIT : [chars]:[dec] (thread:[dec]) fh_init failed [chars] | |
---|---|
Explanation | The fh_init function reported an error trying to initialize the internal callback connection. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMC_CBS_PT_CREATE : [chars]: pthread_create failed [chars] | |
---|---|
Explanation | The pthread_create function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMC_ENQUEUE_FAIL : [chars]: Unable to enqueue [chars]; | |
---|---|
Explanation | The enqueue function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMC_FH_INIT : [chars]: fh_init failed : [dec] | |
---|---|
Explanation | The fh_init function reported an error trying to initialize EEM fora callback process. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMC_INV_REPLY : [chars]: Application client library unable to handle message receive. | |
---|---|
Explanation | The API received a msg reply when it was not in a state to acceptsuch messages. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMC_MALLOC : [chars]: Unable to allocate [chars]; | |
---|---|
Explanation | The malloc function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMC_REG_CBH_PULSE : [chars]: Unable to locate reg callback entry for pulse code [dec] | |
---|---|
Explanation | The registration callback handler was unable to validate the pulse codereceived. |
Recommended Action | The pthread_create function reported an error. |
%HA_EM-7-FMC_REG_CBH_SEND : [chars]: Unable to send response for FH_MSG_CALLBACK_DONE [chars] [dec] | |
---|---|
Explanation | The registration callback handler was unable to send theFH_MSG_CALLBACK_DONE message to the Embedded Event Manager Server. |
Recommended Action | The pthread_create function reported an error. |
%HA_EM-7-FMC_XDM_DISPATCH_FAIL : [chars]: XOS Dispatch Manager dispatch error: [dec] | |
---|---|
Explanation | XOS Dispatch Manager reports an error when dispatching an event. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMC_XDM_WAIT_FAIL : [chars]: XOS Dispatch Manager wait error: [dec] | |
---|---|
Explanation | XOS Dispatch Manager reports an error when waiting for an event. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_ACTION : [chars]: Error occurred while performing action: [chars]. | |
---|---|
Explanation | The Embedded Event Manager Policy Director failed to perform anaction for the registered event. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_ACTION_INFO : [chars]: Error occurred while fetching action information: [dec]. | |
---|---|
Explanation | The Embedded Event Manager Policy Director failed to gather actioninformation registered for the event. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_ACTION_NOTRACK : [chars]: unable to set state for tracking object number [int]; object does not exist or is not a stub-object. |
|
---|---|
Explanation | The Embedded Event Manager applet attempted to set the state ofa tracking object that does not exist. |
Recommended Action | Only set the state of tracking objects that have already been configured in the system. If the message continues to occur, copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_CHECKSUM_MISMATCH : [chars]: file checksum mismatch | |
---|---|
Explanation | The checksum value of an installed policy does not match the valueprovided by the installation manager. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_CHKPT_INIT : [chars]: could not register the application with the checkpointing server: [chars] | |
---|---|
Explanation | Failed to register an application with the checkpointing server. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_CHKPT_ITERATE_END : [chars]: call to chkpt_iterate_end returned unexpected failure. | |
---|---|
Explanation | Failed to register an application with the checkpointing server. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_CHKPT_NULL_PTR : [chars]: Got a null [chars] but non-null value was expected | |
---|---|
Explanation | Failed to do further processing because we got a null data when a non-null value was expected. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_CHKPT_TBL_ADD : [chars]: could not save a record into a checkpointing table: [chars] | |
---|---|
Explanation | Failed to save a record into the given checkpointing table. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_CHKPT_TBL_INFO_READ : [chars]: could not read the existing table information: [chars] | |
---|---|
Explanation | Failed to read the existing table information using checkpointing API. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_CHKPT_TBL_INIT : [chars]: failed to initialize [chars]: [chars] | |
---|---|
Explanation | Could not initialize a table with the checkpointing server. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_CHKPT_TBL_RECOVER : [chars]: could not recover the checkpointed [chars]: [chars] | |
---|---|
Explanation | Failed to recover a checkpointed table. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_CHKPT_TBL_REMOVE : [chars]: could not delete a record from a checkpointing table: [chars] | |
---|---|
Explanation | Failed to delete a record from the given checkpointing table. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_CHKPT_TBL_RESET : [chars]: could not reset a record in a checkpointing table: [chars] | |
---|---|
Explanation | Failed to reset a record in the given checkpointing table. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_CLI_CONNECT : Unable to establish CLI session: [chars] | |
---|---|
Explanation | Unable to establish CLI session. |
Recommended Action |
%HA_EM-3-FMPD_CLI_DISCONNECT : Error disconnecting from CLI session: [chars] | |
---|---|
Explanation | An error occurred while disconnecting from the CLI session. |
Recommended Action |
%HA_EM-3-FMPD_CLI_NOTTY : Error attempting to access an unopened CLI session: [chars] | |
---|---|
Explanation | An error occurred attempting to access an unopened CLI session: %s |
Recommended Action |
%HA_EM-3-FMPD_CLI_READ : Unable to read CLI response: [chars] | |
---|---|
Explanation | Unable to read CLI response. |
Recommended Action |
%HA_EM-3-FMPD_CLI_WRITE : Unable to send CLI command: [chars] | |
---|---|
Explanation | Unable to send CLI command. |
Recommended Action |
%HA_EM-6-FMPD_CONTEXT_RETRIEVE : Failed to retrieve context for key [chars]: [chars] | |
---|---|
Explanation | Failed to context retrieve variable information for event. |
Recommended Action | Ensure context information with the given key is saved. If the message continues to occur, copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-6-FMPD_CONTEXT_SAVE : Failed to save variable context for key [chars]: [chars] | |
---|---|
Explanation | Failed to context save variable information for event. |
Recommended Action | Ensure context information with the same key is not already saved. If the message continues to occur, copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-4-FMPD_DIRECTORY_NOT_EXIST : User policy directory [chars] could not be found on [chars] | |
---|---|
Explanation | A policy directory could not be found. Cold start on this location may result in startup configuration failure. |
Recommended Action | Create the directory on this location. |
%HA_EM-6-FMPD_DIVIDE_ZERO : Invalid operand in arithmetic division, cannot divide by zero | |
---|---|
Explanation | Arithmetic division does not allow divide by zero. |
Recommended Action | Ensure denominator provided to division action is non-zero. |
%HA_EM-4-FMPD_DSIG_TYPE_CHANGE : Cisco Signature not found or invalid. [chars] has been registered as a user policy. | |
---|---|
Explanation | Cisco Signature not found or invalid. |
Recommended Action | Sign with Cisco signature. |
%HA_EM-6-FMPD_EEM_CONFIG : [chars]: [chars] | |
---|---|
Explanation | The Embedded Event Manager reports an error on Event Managerconfiguration |
Recommended Action | Check the EEM applet or policy configuration |
%HA_EM-6-FMPD_EEM_LOG_MSG : [chars] | |
---|---|
Explanation | The Embedded Event Manager reports errors when registering a TCL policy. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_ERROR : Error executing applet [chars] statement [chars] | |
---|---|
Explanation | The Embedded Event Manager policy director found an error whenprocessing an applet. |
Recommended Action | Check syntax of applet statement. If the message continues to occur, copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-4-FMPD_EVENT_CREATE : [chars]: failed to create an event: [chars] | |
---|---|
Explanation | Failed to create an Embedded Event Manager event. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-4-FMPD_EVENT_REG : [chars]: failed to register an event: [chars] | |
---|---|
Explanation | Failed to register an Embedded Event Manager event. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_EVENT_TYPE : [chars]: unknown event type [dec] | |
---|---|
Explanation | An unknown Embedded Event Manager even type was detected. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_EVM_CREATE : [chars]: could not create event manager: [chars] | |
---|---|
Explanation | An internal error was detected when creating Event Manager. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_EVM_EVENT_BLOCK : [chars]: failed to block waiting for Event Manager events: [chars] | |
---|---|
Explanation | An internal error was detected when block waiting for Event Manager events. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_EXECUTE_CALLBACK : [chars]: failed to execute callback | |
---|---|
Explanation | Failed to execute callback routine. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_FH_INIT : [chars]: could not initialize Embedded Event Manager service: [chars] | |
---|---|
Explanation | An internal error was detected when initializing Embedded Event Managerservice. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_FILE_CLOSE : [chars]: failed to close fd [chars] : [chars] | |
---|---|
Explanation | Failed to close the given file descriptor due to some internal error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_FILE_DELETE : [chars]: failed to delete file: [chars] : [chars] | |
---|---|
Explanation | Failed to delete the given file. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_FILE_OPEN : [chars]: failed to open file [chars] : [chars] | |
---|---|
Explanation | Failed to open the given file due to some internal error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_FILE_READ : [chars]: failed to read from fd [chars] : [chars] | |
---|---|
Explanation | Failed to read from the given file descriptor due to some internal error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_FILE_WRITE : [chars]: failed to write to fd [chars] : [chars] | |
---|---|
Explanation | Failed to write to the given file descriptor due to some internal error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_FORMAT_TIME : [chars]: error attemting to format time string | |
---|---|
Explanation | Format time failure. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_GET_PRIO : [chars]: failed to get process priority: [chars] | |
---|---|
Explanation | Internal error. A call to get process scheduling priority failed. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-4-FMPD_IPC_GET_PAK : [chars]: failed to allocate an IPC buffer | |
---|---|
Explanation | Embedded Event Manager failed to allocate a buffer from IPC. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_IPC_PORT_CREATE : [chars]: failed to create an IPC port: [chars] | |
---|---|
Explanation | Embedded Event Manager failed to create an IPC port. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_IPC_PORT_OPEN : [chars]: failed to open an IPC port: [chars] | |
---|---|
Explanation | Embedded Event Manager failed to open an IPC port. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_IPC_PORT_REGISTER : [chars]: failed to register an IPC port: [chars] | |
---|---|
Explanation | Embedded Event Manager failed to register an IPC port. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-4-FMPD_IPC_SEND_MSG : [chars]: failed to send an IPC message: [chars] | |
---|---|
Explanation | Embedded Event Manager failed to send a message through IPC. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_LAST_POLICY : [chars]: invalid last policy name replied [chars] | |
---|---|
Explanation | Internal error. The last policy name the script director repliedto show fm policy registered command is an invalid policy name. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_MEM_ALLOC : Not enough memory ([dec] bytes) | |
---|---|
Explanation | Allocating memory failed due to a low-memory condition. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-4-FMPD_NO_ACTION : No action configured for applet [chars] | |
---|---|
Explanation | No action has been configured for this applet. |
Recommended Action | Configure at least one action for this applet. |
%HA_EM-7-FMPD_NO_CLOCK : [chars]: unable to read clock using clock_gettime: [chars] | |
---|---|
Explanation | The clock_gettime function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_NOEID : [chars]: No such event id found. | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_NOESID : [chars]: No such event spec id found. | |
---|---|
Explanation | The Embedded Event Manager Policy Director could not find the eventfor the event spec. ID. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-4-FMPD_NO_EVENT : No event configured for applet [chars] | |
---|---|
Explanation | No event has been configured for this applet. |
Recommended Action | Configure an event for this applet. |
%HA_EM-7-FMPD_NO_MEM : [chars]: not enough memory: [chars] | |
---|---|
Explanation | Allocating memory failed due to a low-memory condition. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_NO_PROC : [chars]: Failed to create process | |
---|---|
Explanation | The process create function reports an error |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-4-FMPD_NOTAGNAME : [chars]: No tag [chars] found corresponding to this event publish. | |
---|---|
Explanation | The Embedded Event Manager policy director could not associate the tagname with a published event. |
Recommended Action | Only use tagnames in the action info type event reqinfo command which correspond to the published event. |
%HA_EM-6-FMPD_OPERAND_INVALID : Invalid operand in action, expected value within range %ld to %ld, received: [chars] | |
---|---|
Explanation | Arithmetic actions only accept valid long integer values. |
Recommended Action | Ensure value provided to action is long integer. |
%HA_EM-3-FMPD_OVL_NOTIF_REG : [chars]: could not register for Version Manager notification: [chars] | |
---|---|
Explanation | An internal error was detected when registering for Version Manager notification. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_OVL_SETUP_ENV : [chars]: [chars] | |
---|---|
Explanation | Updating environment variables of the process according to system variables stored in sysdb failed. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-4-FMPD_POLICY_APPLY : Could not apply policy ‘[chars]’: [chars] | |
---|---|
Explanation | A policy could not be applied. This message signaled an unsuccessful apply of the policy. |
Recommended Action | Remove the configuration for the policy (and commit), and then attempt to configure the registration of the same policy. |
%HA_EM-6-FMPD_POLICY_CHANGED : [chars]: registered policy [chars] changed by the last installation update | |
---|---|
Explanation | A registered policy was changed by the last installation update. If the update used the start option, the old policy was automatically unregistered and the new policy registered. Otherwise, the old policy would remain registered and functional until the user unregisters it manually. |
Recommended Action | None. |
%HA_EM-4-FMPD_POLICY_CONFIG_INCONSISTENT : Policy ‘[chars]’: [chars] | |
---|---|
Explanation | Some policy configuration is potentially inconsistent, and the user should follow the guidelines in the message to amend this. |
Recommended Action | Examine the guidelines in the message, and the event manager configuration,to determine the potential problem. Note that this is just a warning message, not an error message, as the configuration is legal — it may be the case that the user has intentionally set this configuration. |
%HA_EM-6-FMPD_POLICY_DELETED : [chars]: registered policy [chars] deleted by the last installation update | |
---|---|
Explanation | A registered policy was deleted by the last installation update. If the update used the start option, the policy was automatically unregistered. Otherwise, the policy would remain registered and functional until the user unregisters it manually. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_POLICY_HASH : [chars]: The hash computation routine reported an error; [chars] | |
---|---|
Explanation | The policy dir checksum function reported the specified error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-4-FMPD_POLICY_NOT_EXIST : Policy file [chars] could not be found on [chars] | |
---|---|
Explanation | A policy file could not be found. Cold start on this location may result in startup |
Recommended Action | Copy the policy file to this location. |
%HA_EM-6-FMPD_POLICY_REG_SUCC : [chars]: Policy ‘[chars]’ registered successfully, by user [chars], with persist time [dec] and type [dec] |
|
---|---|
Explanation | A new policy has been registered with Embedded Event Manager. This message signaled a successful registration. |
Recommended Action | None. |
%HA_EM-7-FMPD_POLICY_TBL_REMOVE : [chars]: could not delete a record from a checkpointing table: [chars] | |
---|---|
Explanation | Failed to delete a record from the given checkpointing table. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-4-FMPD_POLICY_TUPLE_UNPACK : Failed to unpack_tuple to get username (Err: [dec]) for [chars] | |
---|---|
Explanation | Failed to unpack sysdb tuple to get the username for the scripts. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_POLICY_UNREG_ERR : [chars]: could not unregister policy [chars]: [chars] | |
---|---|
Explanation | A registered policy changed or deleted by the last installation update was detected. Since the update used the start option, the old policy was automatically unregistered. This message signaled an unsuccessful unregistration. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_POLICY_UNREGREG_ERR : [chars]: could not replace policy [chars]: [chars] | |
---|---|
Explanation | A registered policy changed by the last installation update was detected. Since the update used the start option, the old policy was automatically replaced by the new policy. This message signaled an unsuccessful replacement of the policy. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-6-FMPD_POLICY_UNREGREG_SUCC : [chars]: policy [chars] replaced successfully | |
---|---|
Explanation | A registered policy changed by the last installation update was detected. Since the update used the start option, the old policy was automatically replaced by the new policy. This message signaled a successful replacement of the policy. |
Recommended Action | None. |
%HA_EM-6-FMPD_POLICY_UNREG_SUCC : [chars]: policy [chars] unregistered successfully | |
---|---|
Explanation | A registered policy changed or deleted by the last installation update was detected. Since the update used the start option, the old policy was automatically unregistered. This message signaled a successful unregistration. |
Recommended Action | None. |
%HA_EM-3-FMPD_PROCESS_XML : [chars]: error processing xml buffer | |
---|---|
Explanation | An error occurred processing the event publish information xml buffer. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_QUEUE_INIT : [chars]: could not initialize queue | |
---|---|
Explanation | An internal error was detected when initializing Embedded Event Managerqueue. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_REFRESHTIMER_INIT : Failed to initialize a refresh timer ([chars]): [chars] | |
---|---|
Explanation | Failed to initialize a Embedded Event Manager refresh timer. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-6-FMPD_REGCOMP : Error compiling regular expression: [chars] | |
---|---|
Explanation | An error was encountered when compiling the given regular expression. |
Recommended Action | Check syntax of regular expression pattern. If the message continues to occur, copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_REQINFO : [chars]: Error attempting to fetch event information: [chars]. | |
---|---|
Explanation | The Embedded Event Manager Policy Director failed to receive event infofor a callback. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_SET_INFO : [chars]: Error occurred while fetching variable information: [dec]. | |
---|---|
Explanation | The Embedded Event Manager Policy Director was unable to set thevariable with the requested information. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_SHM_OPEN : [chars]: ERROR opening shared mem IDB | |
---|---|
Explanation | An internal error was detected when attempting to open the IDB shared memory area |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_SMTP : Error occurred when sending mail to SMTP server: [chars] : [chars] | |
---|---|
Explanation | An unexpected error occurred when sending mail to SMTP server. |
Recommended Action |
%HA_EM-3-FMPD_SMTP_SEND : Unable to send notification using all SMTP servers | |
---|---|
Explanation | An unexpected error occurred when sending mail to all SMTP servers. |
Recommended Action |
%HA_EM-6-FMPD_SNMP_DUP_OID : [chars]: duplicate oid | |
---|---|
Explanation | The oid is a duplicate |
Recommended Action | Check the EEM applet or policy configuration |
%HA_EM-6-FMPD_SNMP_NO_VAR : [chars]: No variable [chars] | |
---|---|
Explanation | The variable is not defined. |
Recommended Action | Check the EEM applet or policy configuration |
%HA_EM-6-FMPD_SNMP_TRAPVAR_ADD : [chars]: Error adding trapvar to queue [chars] | |
---|---|
Explanation | The trap variable was not added to the queue. |
Recommended Action | Check the EEM applet or policy configuration |
%HA_EM-6-FMPD_SNMP_VARS_EXCEEDED : [chars]: number of values exceeded [dec] | |
---|---|
Explanation | The number of values per variable exceeded the maximum |
Recommended Action | Check the EEM applet or policy configuration |
%HA_EM-7-FMPD_SWITCH_FAIL : [chars]: The system is unable to switch to standby processor. Switchover cancelled. | |
---|---|
Explanation | Switchovers must occur when STANDBY is available and ready. |
Recommended Action | None Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-6-FMPD_SWITCH_HARDWARE : [chars]: Policy has requested a hardware switchover | |
---|---|
Explanation | An Embedded Event Manager policy requested that a hardware switchoveroccur. |
Recommended Action | None |
%HA_EM-7-FMPD_SYSDB_VERIFY_REG : Could not register for SysDB verification: [chars] | |
---|---|
Explanation | An internal error was detected when trying to register verify function and/or apply function for SysDB tuple operations upon the given item within the given namespace. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_THREAD_POOL : [chars]: [chars] | |
---|---|
Explanation | An internal error was detected while initialization of threadpool. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_UNKNOWN_ENV : [chars]: could not find environment variable: [chars] | |
---|---|
Explanation | The Embedded Event Manager policy director could not find the environmentvariable specified in the action message. |
Recommended Action | Only use well known Embedded Event Manager environment variables. If the message continues to occur, copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMPD_UNKNOWNTYPE : [chars]: Unknown event type found in applet. | |
---|---|
Explanation | The Embedded Event Manager applet had an unknown event type. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-6-FMPD_UPDATE_POLICY_COPY : Policy update has copied [dec] bytes from [chars] to [chars] | |
---|---|
Explanation | An EEM policy has been copied as a result of an event manager update command |
Recommended Action |
%HA_EM-6-FMPD_UPDATE_POLICY_REGISTER : Policy update has successfully re-registered policy [chars] | |
---|---|
Explanation | An EEM policy has been successfully re-registered as a result of an event manager update command |
Recommended Action |
%HA_EM-6-FMPD_UPDATE_POLICY_REGISTER_FAIL : Policy update has failed to register policy [chars] [chars] | |
---|---|
Explanation | An EEM policy has failed to be registered as a result of an event manager update command |
Recommended Action |
%HA_EM-6-FMPD_UPDATE_POLICY_UNREGISTER_FAIL : Policy update has failed to unregister policy [chars] [chars] | |
---|---|
Explanation | An EEM policy has failed to be unregistered as a result of an event manager update command |
Recommended Action |
%HA_EM-3-FMPD_WRONGTYPE : [chars]: Published event type does not match event spec. | |
---|---|
Explanation | The Embedded Event Manager Policy Director detected a mis-match in eventtype between the published event and the event spec. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_XDM_DISPATCH_FAIL : [chars]: XOS Dispatch Manager dispatch error: [dec] | |
---|---|
Explanation | XOS Dispatch Manager reports an error when dispatching an event. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMPD_XDM_WAIT_FAIL : [chars]: XOS Dispatch Manager wait error: [dec] | |
---|---|
Explanation | XOS Dispatch Manager reports an error when waiting for an event. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-ACTION_ADD_PARSER : [chars]: Unable to add action [chars] command; | |
---|---|
Explanation | Failed to add action command. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-ACTION_CNS_AGENT_UNAVAIL : [chars]: CNS Event Agent not available: [dec] | |
---|---|
Explanation | The CNS Event Agent is currently not available. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-ACTION_CNS_CLEAR_RESTART : [chars]: Unable to clear restart callback; | |
---|---|
Explanation | The CNS Action process failed to clear restart callback. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-ACTION_CNS_OPEN_FAIL : [chars]: Unable to open connection to CNS Event Agent: [dec] | |
---|---|
Explanation | The CNS Action process failed to open CNS handle to Event Agent. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-ACTION_CNS_SET_RESTART : [chars]: Unable to set restart callback; | |
---|---|
Explanation | The CNS Action process failed to set the restart callback. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-ACTION_ENQUEUE_FAIL : [chars]: Unable to enqueue [chars]; | |
---|---|
Explanation | The enqueue function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-ACTION_WB_CREATE : [chars]: create_watched_boolean failed: [chars] | |
---|---|
Explanation | The create_watched_boolean function reported an error trying to createthe watched boolean. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-ACTION_WB_DELETE : [chars]: delete_watched_boolean failed: [chars] | |
---|---|
Explanation | The delete_watched_boolean function reported an error trying to delete the watched boolean. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_ASYNC_ATTACH_CHKPT : [chars]: Failed to attach to handle chkpt asynchronous events; [chars] | |
---|---|
Explanation | The event_pulse_attach_event function reported an error trying to attach the chkpt pulse handler. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_ASYNC_ATTACH_DEFAULT : [chars]: Failed to attach to handle default asychronous events; [chars] | |
---|---|
Explanation | The event_pulse_attach_event function reported an error trying to attach the default pulse handler. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_CHKPT_INIT : [chars]: could not register the application with the checkpointing server: [chars] | |
---|---|
Explanation | Failed to register an application with the checkpointing server. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_CHKPT_ITERATE_END : [chars]: call to chkpt_iterate_end returned unexpected failure. | |
---|---|
Explanation | Unexpected error when iterating over a checkpointing table. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_CHKPT_NULL_PTR : [chars]: Got a null [chars] when non-null value was expected | |
---|---|
Explanation | Failed to do further processing because we got a null data when a non-null value was expected. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_CHKPT_TBL_ADD : [chars]: could not add to the checkpointed [chars]: [chars] | |
---|---|
Explanation | Failed to add a record to the checkpointed table. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_CHKPT_TBL_INFO_READ : [chars]: could not read the existing table information: [chars] | |
---|---|
Explanation | Failed to read the existing table information using checkpointing API. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_CHKPT_TBL_INIT : [chars]: failed to initialize [chars]: [chars] | |
---|---|
Explanation | Could not initialize a table with the checkpointing server. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_CHKPT_TBL_RECOVER : [chars]: could not recover for the checkpointed [chars]: [chars] | |
---|---|
Explanation | Failed to recover a record from the checkpointed table. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_CHKPT_TBL_REMOVE : [chars]: could not remove from the checkpointed [chars]: [chars] | |
---|---|
Explanation | Failed to remove a record from a checkpointed table. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_CHKPT_TBL_SAVE : [chars]: could not save to the checkpointed [chars]: [chars] | |
---|---|
Explanation | Failed to save a record to a checkpointed table. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_CHKPT_TBL_UNREG : [chars]: could not unregister the checkpointed table [chars]: [chars] | |
---|---|
Explanation | Failed to unregister a checkpointed table. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMS_CNS_FAIL : [chars]: Failed to perform CNS action: [chars] | |
---|---|
Explanation | The Embedded Event Manager failed attempting to send a CNS message. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_CREATE_THREAD_POOL : [chars]: Error reported by create_thread_pool function; [chars] | |
---|---|
Explanation | The create_thread_pool function reported an error while attempting to create the thread pool. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMS_EMPTY_QUEUE : [chars]: The I/O queue empty. | |
---|---|
Explanation | The I/O queue is empty at this point, and should not be. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMS_ENQUEUE_FAIL : [chars]: The Unable to enqueue packet onto queue. | |
---|---|
Explanation | The queue is not in a state to handle enqueues. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_EVM_CREATE : [chars]: event_manager_create failed; [chars] | |
---|---|
Explanation | The event_manager_create function reported an error trying to initialize the event manager. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_EVM_EVENT_BLOCK : An error occurred while waiting for an event: [chars] | |
---|---|
Explanation | The event infrastructure will ignore this error and continue to wait for the next event. If this error is seen repeatedly, the process may not be able to function and will need to be restarted. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_FDC_ALLOCATE : [chars]: Failed to allocate Event Detector context control block; [chars] | |
---|---|
Explanation | The get_fd function reported an error trying to allocate a Event Detectorcontext control block. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_FDC_OPEN : [chars]: Failed to open Event Detector context control block | |
---|---|
Explanation | The open_fd function reported an error trying to open a Event Detectorcontext control block. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_GET_NODE_NAME : [chars]: platform_get_node_name failed; [chars] | |
---|---|
Explanation | The platform_get_node_name function reported an error trying to obtain the node name. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_GET_NODE_STATE : Failed to get the current nodes state: [chars] | |
---|---|
Explanation | The call to get the nodes current state failed. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_GET_PRIO : [chars]: Failed to get process priority; [chars] | |
---|---|
Explanation | The getprio function reported an error trying to obtain the default process priority. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_GUARD_WORD_VER : [chars]: [chars] guard word corrupted; [IPV6 address] | |
---|---|
Explanation | The guard word for the specified control block does not contain what isexpected. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_INV_ARG_STRING : [chars]: Invalid argument string: [chars] | |
---|---|
Explanation | An invalid argument string was passed to the specified function. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_INV_ENV_STRING : [chars]: Invalid environment string: [chars] | |
---|---|
Explanation | An invalid environment string was passed to the specified function. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_KILL : [chars]: Unable to kill process [chars]; [chars] | |
---|---|
Explanation | The kill function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_KILL_RUN : [chars]: Unable to kill run process [dec] for [chars]; [chars] | |
---|---|
Explanation | The kill function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-6-FMS_LAST_POLICY : [chars]: Cannot change a class [chars] [chars] to priority LAST. LAST is for default policies only |
|
---|---|
Explanation | Embedded Event Manager Scheduler Command can only change a default policy to priority LAST. |
Recommended Action | The command is applicable to default policies only. |
%HA_EM-7-FMS_MALLOC : [chars]: Unable to allocate [chars]; [chars] | |
---|---|
Explanation | The malloc function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_MISC_ERR : [chars] ([chars]) | |
---|---|
Explanation | An unexpected error occurred. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-6-FMS_MODIFY_LAST_POLICY : [chars]: Cannot modify a LAST policy to class [chars]. LAST policies are for class default only. |
|
---|---|
Explanation | Embedded Event Manager LAST policy is for default class only. |
Recommended Action | The command is applicable to default policies only. |
%HA_EM-6-FMS_MODIFY_POLICY : [chars]: unable to modify the policy to class [chars]: scheduling rule unavailable. | |
---|---|
Explanation | There is no scheduler rule configured to service this event class. |
Recommended Action | Please configure a scheduler rule before modifying the event. |
%HA_EM-7-FMS_NO_CLOCK : [chars]: unable to read clock using clock_gettime: [chars] | |
---|---|
Explanation | The clock_gettime function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-4-FMS_NO_SCHED_THREAD : No threads are configured to service event class [chars] | |
---|---|
Explanation | The Embedded Event Manager has no scheduler threads to service this event class. |
Recommended Action | Track ED is not available in this image Configure threads for the event class using the ‘event manager scheduler’ command. |
%HA_EM-3-FMS_NO_TRACK : keyword in the correlate statement is not supported in this image. | |
---|---|
Explanation | The Embedded Event Manager Track ED is not supported in this image. |
Recommended Action | Track ED is not available in this image |
%HA_EM-7-FMS_NULL_SCRIPT_NAME : [chars]: The script name is NULL | |
---|---|
Explanation | An invalid script name was passed as an argument into the specifiedfunction. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMS_OPEN : [chars]: Unable to open [chars]; [chars] | |
---|---|
Explanation | The open function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_OVL_NOTIFY_REG : [chars]: ovl_notification_register failed when registering to handle OVL notifications; [chars] | |
---|---|
Explanation | The ovl_register_notification function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_OVL_SETUP_ENV : [chars]: [chars] | |
---|---|
Explanation | Updating environment variables of the process according to system variables stored in sysdb failed. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMS_POLICY_CHECKSUM : [chars]: Checksum error for policy [chars] — this policy will not be run | |
---|---|
Explanation | The checksum computed for the specified policy does not match the original checksum computed when the policy was registered. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_POLICY_EXEC : [chars]: Policy execution [chars] | |
---|---|
Explanation | The Embedded Event Manager policy excution state has been changed to thestate named in the message. |
Recommended Action |
%HA_EM-3-FMS_POLICY_HASH : [chars]: The hash computation routine reported an error; [chars] | |
---|---|
Explanation | The fh_hash_md5_fd() function reported the specified error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-3-FMS_POLICY_LOOKUP_FAIL : [chars]: Failed to look up in the table the registration specification for policy [chars]. | |
---|---|
Explanation | A table lookup for the registration specification for the policy failed. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_POLICY_MAX_ENTRIES : [chars]: Class [chars]: Maximum number of [dec] [chars] publish entries exceeded; some events have been discarded |
|
---|---|
Explanation | An attempt to publish an event failed because there is no more room in the publish queue |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative |
%HA_EM-6-FMS_POLICY_TIMEOUT : Policy ‘[chars]’ has hit its maximum execution time of [dec].%9.9ld seconds, and so has been halted |
|
---|---|
Explanation | The policy has exceeded its maximum execution time, and so has been halted part way through execution.If this policy is expected to take a long time to run, it may need to have ‘maxrun_sec’ added to the policy registration line (or its value increased if it is already specified). |
Recommended Action | *NONE* |
%HA_EM-3-FMS_QUEUE_INIT : [chars]: The Unable to initialize queue. | |
---|---|
Explanation | The queue cannot be initialized.An attempt to publish an event failed because there is no more roomin the publish queue. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative.Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_REALLOC_FAIL : [chars]: Unable to reallocate [chars]; [chars] | |
---|---|
Explanation | The realloc function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_REG_NODE_STATE_CHANGE : Failed to register for node state changes: [chars] | |
---|---|
Explanation | The call to register for node state changes failed. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-6-FMS_RELOAD_SYSTEM : [chars]: Policy has requested a system reload; | |
---|---|
Explanation | An Embedded Event Manager policy requested that the system be reloaded. |
Recommended Action |
%HA_EM-6-FMS_RUNNING_POLICY : [chars]: cannot [chars] a running policy with jobid [dec]. | |
---|---|
Explanation | Embedded Event Manager Scheduler Command cannot change a running policy. |
Recommended Action | The command is not applicable to a running policy. |
%HA_EM-7-FMS_SPAWN : [chars]: Unable to spawn [chars]; [chars] | |
---|---|
Explanation | The spawn function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_STRDUP : [chars]: Failed to duplicate string [chars]; [chars] | |
---|---|
Explanation | The strdup function reported an error. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_SWITCH_FAIL : [chars]: The system is unable to switch to standby processor. Switchover cancelled. | |
---|---|
Explanation | Switchovers must occur when STANDBY is available and ready. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-6-FMS_SWITCH_HARDWARE : [chars]: Policy has requested a hardware switchover | |
---|---|
Explanation | An Embedded Event Manager policy requested that a hardware switchoveroccur. |
Recommended Action |
%HA_EM-3-FMS_SWITCH_NOT_RF_ACTIVE : [chars]: This processor is not in ACTIVE state (state = [dec]). Switchover must be performed on ACTIVE processor. |
|
---|---|
Explanation | Switchovers must occur on ACTIVE unit, not STANDBY unit. |
Recommended Action |
%HA_EM-7-FMS_SYSLOG_SCAN_RESIGN : [chars]: Failed to unload Syslog FD DLL [chars]; return code=[dec] | |
---|---|
Explanation | The syslog_scan_resign function reported an error trying to unload the specified Syslog Event Detector DLL library. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_SYSLOG_SCAN_SIGNUP : [chars]: Failed to load Syslog FD DLL [chars]; return code=[dec] | |
---|---|
Explanation | The syslog_scan_signup function reported an error trying to load the specified Syslog Event Detector DLL library. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_SYSMGR_RELOAD_FM : [chars]: Failed to load Sysmgr FD DLL [chars]; return code=[dec] | |
---|---|
Explanation | The sysmgr_reload_fh_detector function reported an error trying to load the specified Sysmgr Event Detector DLL library. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_THREADPOOL_MAX : Maximum number ([dec]) of callback events exceeded for [chars]; There is no available thread in the threadpool to service the event. |
|
---|---|
Explanation | An attempt to schedule an event requiring a callback failed because there is no available thread in the threadpool. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_THREAD_POOL_START : [chars]: Error reported by thread_pool_start function; [chars] | |
---|---|
Explanation | The thread_pool_start function reported an error while attempting to start the thread pool. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_WB_CREATE : [chars]: create_watched_boolean failed; [chars] | |
---|---|
Explanation | The create_watched_boolean function reported an error trying to createthe watched boolean. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_WDSYSMON_RELOAD_FM : [chars]: Failed to load WDSysMon FD DLL [chars]; return code=[dec] | |
---|---|
Explanation | The wd_reload_fh_detector function reported an error trying to load the specified WDSysMon Event Detector DLL library. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_WQ_CREATE : [chars]: create_watched_queue failed; [chars] | |
---|---|
Explanation | The create_watched_queue function reported an error trying to createthe watched queue. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_XDM_DISPATCH_FAIL : [chars]: XOS Dispatch Manager dispatch error: [dec] | |
---|---|
Explanation | XOS Dispatch Manager reports an error when dispatching an event. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_XDM_WAIT_FAIL : [chars]: XOS Dispatch Manager wait error: [dec] | |
---|---|
Explanation | XOS Dispatch Manager reports an error when waiting for an event. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
%HA_EM-7-FMS_XOS_DM_EXECUTE : [chars]: Failed to attach a handler to process child process exit; [chars] | |
---|---|
Explanation | The xos_dm_execute function reported an error trying to attach the handler to process child process exit. |
Recommended Action | Copy the message exactly as it appears, and report it your technical support representative. |
HA_PROXY
%HA_PROXY-3-PROXY_IPC_PAK_ALLOC_FAILED : | |
---|---|
Explanation | Allocation of IPC packet failed. |
Recommended Action | LOG_STD_ACTION |
%HA_PROXY-2-HA_SESSION_ALLOC_FAILED : [chars]: unable to allocate entry for [chars] binding | |
---|---|
Explanation | HA could not allocate a control block to manage the service |
Recommended Action | LOG_STD_ACTION |
%HA_PROXY-2-HA_FIND_SERVICE_FAILED : [chars]: unable to find [chars] service | |
---|---|
Explanation | HA could not find the specified service |
Recommended Action | LOG_STD_ACTION |
%HA_PROXY-3-HA_DUP_SERVICE_NAME : [chars]: Duplicate service name: [chars] on bind | |
---|---|
Explanation | Duplicate service name on ha service bind |
Recommended Action | LOG_STD_ACTION |
%HA_PROXY-3-HA_DUP_SERVICE_INDEX : [chars]: Duplicate service index: [dec] on bind | |
---|---|
Explanation | Duplicate service index on ha service bind |
Recommended Action | LOG_STD_ACTION |
%HA_PROXY-3-HA_INVALID_REQUEST : [chars]: Unknown request: [dec] | |
---|---|
Explanation | HA control services received unknown request |
Recommended Action | LOG_STD_ACTION |
%HA_PROXY-3-HA_MALFORMED_PKT : Malformed packet bad [chars] [hex], MSGDEF_LIMIT_MEDIUM | |
---|---|
Explanation | HA Sync packet was malformed, may not have been fully processed |
Recommended Action | LOG_STD_ACTION |
%HA_PROXY-4-HA_UNKNOWN_SERVICE : Sync msg for unknown service [hex] rg [hex], MSGDEF_LIMIT_MEDIUM | |
---|---|
Explanation | HA Sync received a message for an unknown service |
Recommended Action | LOG_STD_ACTION |
%HA_PROXY-4-HA_PKT_ERROR : Error processing HA sync pkt, rg [hex], MSGDEF_LIMIT_MEDIUM | |
---|---|
Explanation | HA Sync packet was dropped while processing |
Recommended Action | LOG_STD_ACTION |
HDLC
%HDLC-1-ISSU_NOMEMORY : msgtxt_nomemory | |
---|---|
Explanation | The requested operation could not be accomplished because of a low memory condition. |
Recommended Action | Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. |
%HDLC-4-ISSU_SENDFAILED : HDLC ISSU: send message failed, rc = [dec] | |
---|---|
Explanation | The sending of a message has failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HDLC-4-ISSU_INCOMPATIBLE : hdlc-issu-compat: returned FALSE | |
---|---|
Explanation | The compatibility checking has failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HDLC-4-ISSU_XFORM : [chars]: failed, rc=[chars] | |
---|---|
Explanation | The transform has failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
HFSLIB
%HFSLIB-3-HFSOPEN : Problem accessing the udev generated file: [chars] | |
---|---|
Explanation | No explanation. |
Recommended Action | No action is required. |
%HFSLIB-3-HFSINOFAILED : Inotify failed to initialize : [chars] | |
---|---|
Explanation | This error occurs when the inotify sub-system is misbehaving |
Recommended Action | No action is required. |
%HFSLIB-3-HFSINOWATCH : Inotify failed to add a watch: [chars] | |
---|---|
Explanation | This error occurs when the inotify sub-system is misbehaving |
Recommended Action | No action is required. |
HMAN
%HMAN-3-CONSOLE_SETUP_FAILED : Failed to setup console service. It should be enabled on [chars] | |
---|---|
Explanation | Setup of a console service failed. |
Recommended Action | Check the host manager launch parameters and correct as required. |
%HMAN-3-HOSTNAME_SET_FAILED : Failed to set hostname: [chars] | |
---|---|
Explanation | The host manager received notification that the system hostname has been set. The host manager failed to pass this value to the ASR kernel. |
Recommended Action | Repeat the process to configure the hostname. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case, or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HMAN-2-INITIALIZATION_FAILED : Host Manager initialization failed. | |
---|---|
Explanation | Initialization of the host manager failed. |
Recommended Action | Review Host Manager logs taking note of the timestamp information to select specific information to review. Copy the message and other related information exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case, or contact your Cisco technical support representative and provide the representative with the gathered information. |
HMAN_CPU
%HMAN_CPU-3-PAGE_FAULT_HIGH : CPU Usage due to Memory Pressure exceeds threshold on [chars]. Below are the top 5 memory consuming processes: [chars] (PID=[dec] RSS=[dec] MB), |
|
---|---|
Explanation | When CPU usage due to Major Page Fault exceeds a pre-defined threshold for a CPU core, this error message is emitted. |
Recommended Action | No action is needed if system continues to perform as expected. If sytem performance deteriorate (and eventually, system reloads due to unspecified reason) around the time when this message is observed, open a case with the Technical Assistance Center via the following Internet link, or contact your Cisco technical support representative: https://mycase.cloudapps.cisco.com/case |
HPI
%HPI-3-FAILED_START : channel:[chars] DSP ID:[hex], failed mode [dec] for service [dec] | |
---|---|
Explanation | Failed to start DSP services |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HPI-3-INVALID_PAYLOAD : wrong payload size, channel:[chars] DSP ID:[hex], failed mode [dec] for service [dec] | |
---|---|
Explanation | Failed to start DSP services |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HPI-3-CODEC_NOT_LOADED : channel:[chars] DSP ID:[hex], command failed as codec not loaded [dec] | |
---|---|
Explanation | Sending messages to DSP without a loaded codec can result with the DSP failing |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HPI-4-INVALID_CODEC_LOAD : channel:[chars] DSP ID:[hex], invalid hpi mode [dec] for loading codec [dec] | |
---|---|
Explanation | Attempt to load codec when the DSP is in an invalid mode which can result with DSP failure |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HPI-4-NO_CLOSE : channel:[chars] DSP ID:[hex] | |
---|---|
Explanation | Attempt to release DSP without sending close message |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HPI-4-INVALID_ECAN_TYPE : [chars] ECAN is not available in voice-card [dec], [chars] ECAN will be used | |
---|---|
Explanation | All voice cards participated in DSPFarm must have the same echo canceller type |
Recommended Action | Make sure all voice cards participated in DSPFarm have the same echo canceller type configured |
%HPI-3-GSMAMRNB_LICENSE_NOT_ACTIVATED : ********************************************************* GSM AMR-NB License is not yet activated. Please configure ‘license feature gsmamrnb-codec-pack’ and accept the EULA to activate the license. ********************************************************* |
|
---|---|
Explanation | Failed to start DSP services for GSM AMR-NB codec |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HPI-6-SRTP_EVAL_LIMIT : The SRTP bandwidth and tunnels usage exceed the license limits | |
---|---|
Explanation | The SRTP bandwidth and tunnels exceed the license limits |
Recommended Action | No action is required. |
%HPI-3-SRTP_EVAL_FREE_ERROR : Error encountered on release SRTP bandwidth and tunnels reservation | |
---|---|
Explanation | Error encountered on release SRTP bandwidth and tunnels |
Recommended Action | No action is required. |
%HPI-3-NACK_HIGH : DSP to IOS Nack message with severity [chars] [chars] [chars] | |
---|---|
Explanation | DSP to IOS Nack message with high severity |
Recommended Action | Check the NACKed message’s parameters for configuration errors. These messages tend to affect call flow, thus they are labeled with high severity. |
%HPI-4-NACK_MED : DSP to IOS Nack message with severity [chars] [chars] [chars] | |
---|---|
Explanation | DSP to IOS Nack message with medium severity |
Recommended Action | Check the NACKed message’s parameters for minor configuration errors. |
%HPI-6-NACK_LOW : DSP to IOS Nack message with severity [chars] [chars] [chars] | |
---|---|
Explanation | DSP to IOS Nack message with low severity |
Recommended Action | Information only, displaying NACKed messages that are for debugging purposes. |
%HPI-6-NACK : DSP to IOS Nack message [chars] [chars] | |
---|---|
Explanation | DSP to IOS Nack message with no severity in order to work with dspware without Nack severity implementation |
Recommended Action | Information only, displaying NACKed messages. |
HSRP
%HSRP-3-NOSOCKET : Unable to open socket | |
---|---|
Explanation | The system was unable to initialize an IP connection for the Hot Standby protocol. |
Recommended Action | Make sure that there is at least one interface configured to run IP. |
%HSRP-4-BADAUTH : Bad authentication from [chars], group [dec], remote state [chars] | |
---|---|
Explanation | Two routers participating in HSRP disagree on the valid authentication string. |
Recommended Action | Use the standby authentication command to repair the HSRP authentication discrepancy between the local system and the one whose IP address is reported. |
%HSRP-4-BADAUTH2 : Bad authentication from [chars] | |
---|---|
Explanation | Two routers participating in HSRP disagree on the valid authentication string. |
Recommended Action | Use the standby authentication command to repair the HSRP authentication discrepancy between the local system and the one whose IP address is reported. |
%HSRP-3-MISCONFIG : Attempt to change [chars] MAC address to [enet] when DECNET already running | |
---|---|
Explanation | An HSRP group attempted to become active on an interface that can only support a single MAC address and which is running DECnet. If standby use-bia is not configured then HSRP would normally set the interface MAC address to the HSRP virtual MAC address, but this is not allowed if DECnet is running. |
Recommended Action | Enable standby use-bia on the interface. |
%HSRP-5-STATECHANGE : [chars] Grp [dec] state [chars] -> [chars] | |
---|---|
Explanation | The router has changed state |
Recommended Action | No action is required. |
%HSRP-4-DUPADDR : Duplicate address [chars] on [chars], sourced by [enet] | |
---|---|
Explanation | The IP address in an HSRP message received on the specified interface is the same as the IP address of the router. Another router might be configured with the same IP address. The most likely cause is a network loop or a misconfigured switch that is causing the router to see its own HSRP Hello messages. |
Recommended Action | Check the configurations on all the HSRP routers to ensure that the interface IP addresses are unique. Check that no network loops exist. If port channels are configured check that the switch is correctly configured for port-channels. Enable standby use-bia so that the error message displays the interface MAC address of the sending router. This can be used to determine if the error message is caused by a misconfigured router or a network loop. |
%HSRP-4-DUPVIP1 : [chars] Grp [dec] address [chars] is already assigned to [chars] group [dec] | |
---|---|
Explanation | The HSRP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to a different HSRP group. |
Recommended Action | Check the configuration on all HSRP routers and ensure that the virtual IP address of each HSRP group is unique. |
%HSRP-4-DUPVIP2 : [chars] Grp [dec] address [chars] is already assigned on this interface | |
---|---|
Explanation | The HSRP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to this interface. |
Recommended Action | Check the configuration on all HSRP routers and ensure that the virtual IP address of each HSRP group is unique. |
%HSRP-4-DUPVIP3 : [chars] Grp [dec] address [chars] is already assigned to, or overlaps with, an address on another interface or application |
|
---|---|
Explanation | The HSRP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to, or overlaps with, an address on another interface or application. |
Recommended Action | Check the configuration on all HSRP routers and ensure that the virtual IP address of each HSRP group is unique. |
%HSRP-4-BADVIP : [chars] Grp [dec] address [chars] is in the wrong subnet for this interface | |
---|---|
Explanation | The HSRP virtual IP address contained in the Hello message cannot be learnt as it is not within a subnet configured on the interface. |
Recommended Action | Check the configuration on all HSRP routers and ensure that the virtual IP address is within a configured subnet. |
%HSRP-4-DIFFVIP1 : [chars] Grp [dec] active routers virtual IP address [chars] is different to the locally configured address [chars] |
|
---|---|
Explanation | The HSRP virtual IP address contained in the Hello message from the Active router is different from the virtual IP address configured locally. |
Recommended Action | Check the configuration on all HSRP routers in the group and ensure they are all configured with the same virtual IP address. |
HTSP
%HTSP-3-NOEVENT : no free event structure available from [chars] for DSP message | |
---|---|
Explanation | There were no event structures remaining in the system pools to alert the router of a voice or signaling event. |
Recommended Action | Check that the voice port for which the event was reported is still operational. If not, clear the voice port. |
%HTSP-3-CAPABILITYMISMATCH : voice port [chars]: call connection id [[hex] [hex] [hex] [hex]] | |
---|---|
Explanation | There was a capabilities mismatch between the two call legs. capabilities are negotiated between call legs for CODEC, VAD and FAX rate. |
Recommended Action | Check that the dial peer configuration is appropriate for the interface in question. Also check that and configuration on the interface is correct. |
%HTSP-3-DSPALARM : voice port [chars]: status=[hex] message=[hex] text=[chars] | |
---|---|
Explanation | The DSP reported a fatal error. All calls on the DSP were dropped and a DSP reload was attempted. |
Recommended Action | Verify that the DSP reloaded properly by attempting to place a call on the affected voice port. Contact your technical support representative, include the full text of the error message. |
%HTSP-3-TRUNKNOTSUPPORTED : voice port [chars]: Ground Start trunking not supported | |
---|---|
Explanation | This voice port does not support the ‘connection trunk’ command when ground start signaling is configured. Trunking mode on this voice is supported when using loop start signaling. |
Recommended Action | Shut down the voice port, remove the ‘connection trunk’ and/or ‘signal groundStart’ command from the voice port configuration, and unshut the voice port. |
%HTSP-5-UPDOWN : Trunk port(channel) [[chars]] is [chars] | |
---|---|
Explanation | Trunk port:channel changed state. |
Recommended Action | No action is required. |
%HTSP-3-CADENCENOTSUPPORTED : voice port [chars]: ring cadence not suitable for caller id. on_time_first=[dec] off_time_first=[dec] on_time_second=[dec] off_time_second=[dec] |
|
---|---|
Explanation | Ring off period is not sufficient for caller id transmission. If caller id transmission during ring is configured make sure that the ring off duration is long enough. |
Recommended Action | If caller id transmission during ring is configured make sure that the ring off duration is long enough. Make sure that the cptone setting and caller-id alerting settings are correct. |
%HTSP-5-VPM_BUSYOUT : voice port [chars]: [chars] busyout | |
---|---|
Explanation | voice port busyout status changed |
Recommended Action | use SHOW VOICE BUSYOUT to find out the reason why voice port busyout monitoring is triggered |
%HTSP-5-VPM_PCM_CAPTURE : User trigger PCM capture is [chars] on voice port [chars] | |
---|---|
Explanation | User trigger PCM capture is enabled or disable on this voice port |
Recommended Action | This is just for information only |
%HTSP-5-VPM_CABLE_STAT : voice port [chars]: cable [chars] | |
---|---|
Explanation | Cable for analog voice port is reconnected or removed |
Recommended Action | Check the cable connection for this analog voice port |
HTTP through IDB_IDENTITY
-
HTTP
-
HTTPC
-
HUNTGRP
-
HW_API
-
HW_FLOWDB
-
HW_IDPROM_ENVMON
-
HW_PFU
-
ICC
-
IDBMAN
-
IDB_IDENTITY
HTTP
%HTTP-3-PROC_NOCREAT : Unable to create HTTP process. | |
---|---|
Explanation | An error occurred during initialization of the HTTP process. The HTTP process that processes all HTTP requests and responses could not be created. |
Recommended Action | Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. |
%HTTP-4-SERVER_CONN_RATE_EXCEED : Number of connections per minute has exceeded the maximum limit([dec]) as specified by the platform. |
|
---|---|
Explanation | The message indicates that the current number of connections requested per minute has exceeded the limit specified by the platform. HTTP server will resume accepting the connections 15 seconds from the time the message is issued. This restriction is done as per the HTTP throttling functionality. |
Recommended Action | Reduce connection rate to the server. |
%HTTP-3-OUTOF_MEM : HTTP out of memory. | |
---|---|
Explanation | An error occurred during initialization of the HTTP process. The HTTP process could not create crucial internal data structures that are required for operation of the HTTP subsystem. The most likely reason for this condition is an exhaustion of system memory. |
Recommended Action | Reduce other system activity to ease memory demands. if conditions warrant, upgrade to a larger memory configuration. |
%HTTP-3-INIT_FAIL : HTTP Process Init failed. | |
---|---|
Explanation | Initialization of the HTTP Subsystem has failed |
Recommended Action | Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. |
%HTTP-6-SERVER_SETUP_FAILED : Server setup failed | |
---|---|
Explanation | Setup of the HTTP(S) server to listen on the specified port number has failed. |
Recommended Action | Disable the server, verify that port number is correct and enable the server. Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration. |
HTTPC
%HTTPC-3-PROC_NOCREAT : Unable to create HTTP Client process. | |
---|---|
Explanation | |
Recommended Action |
%HTTPC-3-OUTOF_MEM : HTTP Client out of memory. | |
---|---|
Explanation | |
Recommended Action |
%HTTPC-3-CACHE_MEM : HTTP Client Cache Init out of memory. | |
---|---|
Explanation | |
Recommended Action |
%HTTPC-3-INIT_FAIL : HTTP Client Process Init failed. | |
---|---|
Explanation | |
Recommended Action |
%HTTPC-3-OUTOF_SYNC : HTTP Client header tables out of sync. | |
---|---|
Explanation | |
Recommended Action |
%HTTPC-6-CONNECT_FAILED : The connection to server [IP_address] failed | |
---|---|
Explanation | |
Recommended Action |
%HTTPC-3-RECEIVE_SOCK_READ_EVENT_WHILE_DISABLED : Received socket read event while read interest is disabled callID([dec]) fd([dec]) — closing socket. |
|
---|---|
Explanation | The HTTP Client is receiving the socket READ event while the READ interest is being disabled. Something has gone wrong between the http client and the socket interfaced. |
Recommended Action | Record the error and report it to the system administrator. |
%HTTPC-3-CONNECT_NULL : NULL connection structure for fd([dec]) — closing socket. | |
---|---|
Explanation | The HTTP Client is receiving the socket READ event but it fails to locate the connection structure for this file descriptor(fd). If this is seen continuously in a loop, it is an indication that something has gone wrong in the socket code. Since the socket is immediately closed after this event, the HTTP client should stop seeing READ event. |
Recommended Action | Record the error and traceback and report it to the system administrator. |
%HTTPC-6-REQUEST_FAILED : request URI [chars] failed | |
---|---|
Explanation | |
Recommended Action |
%HTTPC-6-CLOSE_SRV_CONNECT : The connection to server [IP_address] appears to be hung and will be closed. | |
---|---|
Explanation | Messages are being backed up in the HTTP Client’s write queue in the connection with the specified server. The connection is assumed to have gone bad and the HTTP Client is closing the connection. |
Recommended Action | Check with the specified server for possible connection error. |
%HTTPC-3-COOKIE_MEM : HTTP Client runs out of allowable memory to store cookies. | |
---|---|
Explanation | The total memory allocated for storing cookies has run out. All cookies received from the HTTP server will be dropped. Users may no longer be able to interact with a session-based origin server until memory is freed up. |
Recommended Action | Users may want to try their requests at a later time or contact the system administrator to increase the maximum RAM allowed for saving HTTP cookies. |
HUNTGRP
%HUNTGRP-3-INVALID_URL : Could not open the file provided in URL: <[chars]> | |
---|---|
Explanation | URL path provided can’t be accessed. This usually indicates that path provided is invalid but may also be because the the path doesn’t allow anonymous access to create files or open it in write mode |
Recommended Action | Check that the url path provided is valid |
%HUNTGRP-3-WRITE_FAIL : Could not write data to the URL: <[chars]>t %%bytes written=[dec] out of [dec] | |
---|---|
Explanation | Write attempt to the url path provided was unsuccessful. This usually indicates that the file was successfully opened with write and append permissions but writing all the content from buffer or may be some of it to the file failed. |
Recommended Action |
HW_API
%HW_API-3-RESILIENCE_NO_HANDLER : No handlers in place for [chars] sw object creation failure. | |
---|---|
Explanation | COMMON_HW_API_INTERNAL_ERROR |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HW_API-3-INVALID_OBJ : Invalid object [hex] | |
---|---|
Explanation | HW_API_INTERNAL_ERROR |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HW_API-3-INVALID_TYPE : Invalid type [dec] | |
---|---|
Explanation | HW_API_INTERNAL_ERROR |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HW_API-3-INVALID_WALK_SPEC : Invalid walk spec [hex] | |
---|---|
Explanation | HW_API_INTERNAL_ERROR |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HW_API-3-WALK_MODE_UNSUPPORTED : Walk mode ‘[chars]’ unsupported | |
---|---|
Explanation | HW_API_INTERNAL_ERROR |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HW_API-3-INVALID_CONTEXT : Invalid context [hex] | |
---|---|
Explanation | HW_API_INTERNAL_ERROR |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HW_API-3-BACKWALK_REQUEST : Backwalk request failed, [chars] | |
---|---|
Explanation | A request to walk internal data structures has failed. Depending on criticality of the data, accuracy of forwarding may impacted. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HW_API-3-BACKWALK_REQUEST_VALUE : Backwalk request failed, [chars] ([hex]) | |
---|---|
Explanation | A request to walk internal data structures has failed. Depending on criticality of the data, accuracy of forwarding may impacted. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HW_API-3-VECTOR : Failed to set [chars] vector for [chars], [chars] | |
---|---|
Explanation | HW_API_INTERNAL_ERROR |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HW_API-3-NO_OBJ_TYPE_LIST_ENTRY : Invalid sw_obj_type ([dec]) used with obj_type_list | |
---|---|
Explanation | HW_API_INTERNAL_ERROR |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HW_API-3-NO_OBJ_TYPE_LIST_ENTRY2 : Invalid sw_obj_link_type ([dec]) used with obj_type_list | |
---|---|
Explanation | HW_API_INTERNAL_ERROR |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HW_API-3-INIT_FAIL : HW-API init [chars] failed[chars] | |
---|---|
Explanation | HW_API_INTERNAL_ERROR |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
HW_FLOWDB
%HW_FLOWDB-3-HW_FLOWDB_OOM : FlowDB memory usage exceeded 95[int]sage. OOM condition can occur. | |
---|---|
Explanation | FlowDB running low on memory. Out-of-memory condition can occur |
Recommended Action | Check sw-distrib for actual utilization of FlowDB memory |
HW_IDPROM_ENVMON
%HW_IDPROM_ENVMON-3-HW_IDPROM_FIELD_INVALID : The idprom contains an invalid environmental monitoring field. | |
---|---|
Explanation | If this error occurs then parsing of the environmental monitoring data is aborted. Environmental monitoring will be either incomplete or absent entirely. |
Recommended Action | If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HW_IDPROM_ENVMON-3-HW_IDPROM_CHECKSUM_INVALID : The idprom contains an invalid checksum in a sensor entry. Expected: [hex], calculated: [hex] |
|
---|---|
Explanation | If this error occurs then parsing of the environmental monitoring data is aborted. Environmental monitoring will be either incomplete or absent entirely. |
Recommended Action | If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HW_IDPROM_ENVMON-2-ACT2_UDI_DATA_INVALID : The act2 udi secure area format mismatch with unsecure area | |
---|---|
Explanation | This Router may not have been manufactured by Cisco or with Cisco’s authorization. This product may contain software that was copied in violation of Cisco’s license terms. If your use of this product is the cause of a support issue, Cisco may deny operation of the product, support under your warranty or under a Cisco technical support program such as Smartnet. Please contact Cisco’s Technical Assistance Center for more information. |
Recommended Action | If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HW_IDPROM_ENVMON-3-PS_IDPROM_INVALID_PID : [chars] in slot PFU[dec] has INVALID PID [chars] and it needs to be replaced immediately | |
---|---|
Explanation | The PID read from the PEM IDPROM is not supported in this hardware configuration. It will be allowed to continue but immediate replacement is required |
Recommended Action | If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
HW_PFU
%HW_PFU-3-PFU_IDPROM_READ_ERR : Could not read the PEM/FM idprom in slot P[dec].The system will run without environmental monitoring for this component |
|
---|---|
Explanation | The idprom contains information required in order to properly operate the environmental monitoring subsystems. The idprom could not be read, therefore no monitoring will take place. |
Recommended Action | If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HW_PFU-3-PFU_IDPROM_CORRUPT : The PEM/FM idprom could be read, but is corrupt in slot P[dec] The system will run without environmental monitoring for this component |
|
---|---|
Explanation | The idprom contains information required in order to properly operate the environmental monitoring subsystems. The idprom could not be read, therefore no monitoring will take place. |
Recommended Action | If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%HW_PFU-3-PFU_IDPROM_INVALID_PID : The PEM/FM idprom has invalid PID in slot PFU[dec] The system will run without environmental monitoring for this component |
|
---|---|
Explanation | The idprom contains PID information required in order to properly operate the environmental monitoring subsystems. The idprom PID is invalid , therefore no monitoring will take place. |
Recommended Action | If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
ICC
%ICC-2-NOMEM : No memory available for [chars] | |
---|---|
Explanation | The ICC subsystem could not obtain the memory it needed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%ICC-4-CONSISTENCY : Internal consistency check: [chars] | |
---|---|
Explanation | An internal inconsistency was found in some ICC data structures. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%ICC-4-COMM : Communication failure occurred while [chars] | |
---|---|
Explanation | |
Recommended Action |
%ICC-4-BAD_ACCOUNTING : ICC received a bad class [dec] | |
---|---|
Explanation | A communication failure has occurred between this card and another card in the system. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%ICC-4-HEARTBEAT : Card [dec] failed to respond to heartbeat | |
---|---|
Explanation | A communication failure has occurred between the primary and the specified line card. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%ICC-5-WATERMARK : [dec] [chars] [chars] pkts for class [chars] are waiting to be processed | |
---|---|
Explanation | Processor got packets for the class and are waiting to be procssed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%ICC-2-OPEN : ICC Create Session Failed for card <[hex]> Queue <[chars]> | |
---|---|
Explanation | ICC was not able to create a session for the destination seat |
Recommended Action | collect output from ‘show oir debug swover_global_mask’ from SP |
%ICC-2-JOIN : ICC mcast joining failed member <[hex]> to group <[hex]> with ipc error <[chars]> | |
---|---|
Explanation | ICC was not able to join a member for the mcast group |
Recommended Action | collect output ‘show icc mcast status’ from RP |
%ICC-5-HUGE_BUFFER : Class [[chars]] with Request id [dec] requested a huge buffer of Size [dec]. | |
---|---|
Explanation | Huge packet requests would deplete the memory at the linecards |
Recommended Action | ICC client is trying to request huge packet buffer Please use the command Show icc internal to get get the traceback and file a DDTS against the component |
%ICC-3-MAST_BAD_FREE : ICC multicast memory already freed | |
---|---|
Explanation | One of the ICC multicast request’s memory was found to be free when response arrived |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
IDBMAN
%IDBMAN-3-VLANINUSE : [chars]: Vlan [dec] is in use by [chars] | |
---|---|
Explanation | Each L3 interface has a Vlan associated with it. This message indicates that the Vlan associated with the interface is being used by some other L3 Interface, which is not anticipated to happen |
Recommended Action | No action is required. |
%IDBMAN-3-INVALIDVLAN : [chars]: trying to use invalid Vlan [dec] | |
---|---|
Explanation | There is an internal error that caused an invalid Vlan to be used by the software. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDBMAN-3-VLANNOTSET : [chars]: Vlan [dec] not set since it already has Vlan [dec] | |
---|---|
Explanation | There is an internal error that caused an interface to not have its Vlan set to the requested value |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDBMAN-6-VLANMAPPED : Vlan [dec] is mapped to [chars] | |
---|---|
Explanation | Informational message indicating that the given Vlan is mapped to the given interface |
Recommended Action | No action is required. |
%IDBMAN-3-AGGPORTMISMATCH : [chars]([dec] / [dec]) does match internal slot/port state [chars]([dec] / [dec]) | |
---|---|
Explanation | There is an internal error that caused an invalid aggregate port to be used by the software. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDBMAN-3-INVALIDAGGPORTBANDWIDTH : [chars]([dec] / [dec]) has an invalid bandwidth value of [dec] | |
---|---|
Explanation | There is an internal error that caused an invalid bandwidth to be used for an aggregate port. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDBMAN-3-DELETEDAGGPORT : [chars]([dec] / [dec]) Group [dec] has been deleted, but is being reused. | |
---|---|
Explanation | There is an internal error that caused an interface that has been deleted to be reused for a new aggregate port. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDBMAN-3-NOTANAGGPORT : [chars]( [dec] / [dec] ) is not an aggregate port | |
---|---|
Explanation | There is an internal error that caused an interface that is not an aggregate port to be used for aggregate port operations |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDBMAN-3-INVALIDPORT : [chars]: trying to use invalid port number [dec] ( Max [dec] ) | |
---|---|
Explanation | There is an internal error that caused an invalid port numer to be used by the software. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDBMAN-4-ACTIVEPORTSINAGGPORT : [chars]( [dec] / [dec] ) has [dec] active ports, but is being removed | |
---|---|
Explanation | There is an internal error that caused an aggregate port with active ports to be removed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDBMAN-3-PORTNOTINAGGPORT : [chars]([dec] / [dec]) is not present in Aggport [chars]([dec] / [dec]) | |
---|---|
Explanation | There is an internal error that caused an invalid port to be referred to be part of an aggregate port. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDBMAN-4-REMOVED_NONDEFAULT_CONFIG : Removed non default configuration for interfaces in slot [dec] | |
---|---|
Explanation | In SSO mode, the non-default configuration for any removed linecard is not synced to the standby during the bulk sync, and it is removed from the configuration to avoid a config mismatch between active and standby supervisors. |
Recommended Action | No action is required. |
%IDBMAN-3-IIF_ID_REGISTRATION_FAILED : IIF_ID registration failed for Port [chars] due to memory allocation failure. Port has been shutdown |
|
---|---|
Explanation | The system is low on memory due to which IIF-ID registration failed. This results in failure to apply polices such as QoS and Security acls on this port. |
Recommended Action | LOG_STD_REDUCE_ACTION Once memory is available, run ‘no shutdown’ on the port. |
IDB_IDENTITY
%IDB_IDENTITY-3-MALLOC : Memory allocation failure for HWIDB type [dec] | |
---|---|
Explanation | A memory allocation failure occured when trying to allocate the identity for this HWIDB. This HWIDB will not be allocated an IF Index which will prevent it from being used for forwarding data. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IDB_SGI through ILPOWER
-
IDB_SGI
-
IDMGR
-
IEDGE
-
IF
-
IFDAMP
-
IFMAP
-
IFMGR
-
IFS
-
IKEV2
-
ILPOWER
IDB_SGI
%IDB_SGI-2-XDRREG : [chars] | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDB_SGI-2-MEMREQ : [chars] | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDB_SGI-3-BADPTR : [chars] of interface with ifindex [int] is invalid | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDB_SGI-3-MEMFAIL : [chars] | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDB_SGI-4-MEMBERREQ : member request failure for interface with ifindex [int] returned err — [chars] | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDB_SGI-3-XDRREQ : [chars] | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDB_SGI-4-INTERR : [chars] for interface with ifindex [int] | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDB_SGI-4-UNEXPINP : [chars] | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IDMGR
%IDMGR-3-MALLOC_FAILURE : [chars] | |
---|---|
Explanation | A malloc failure occured in ID Manager. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDMGR-3-INTERRUPT : [chars] | |
---|---|
Explanation | An id_get attempted at interrupt level. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDMGR-3-INVALID_ID : bad id in [chars] (id: [hex]) | |
---|---|
Explanation | An ID Manager error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDMGR-3-INVALID_ID_TABLE_SIZE : bad new ID table size | |
---|---|
Explanation | A bad new table request to ID Manager occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IDMGR-3-ID_MANAGER_INTERNAL_ERROR : [chars] | |
---|---|
Explanation | Internal Error occured with ID Manager. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IEDGE
%IEDGE-4-PBHK_DEPLETED_INDICES : No more portbundles can be allocated | |
---|---|
Explanation | The source interfaces configured for Portbundle Hostkey feature are not sufficient and the number of portbundles available are all used up. Add more source interfaces in the configuration. |
Recommended Action | Check configuration on the ISG |
%IEDGE-4-TC_UNDEFINED_ACL : Traffic class ACL [chars] is not defined, creating permit all ACL | |
---|---|
Explanation | The ACL specified for classification of traffic is not configured on the ISG. Creating a permit all ACL. ACL should be configured on the ISG. |
Recommended Action | Configure the ACL on the ISG |
%IEDGE-4-CLOCK_CHANGE_TIMER_INV : A Local clock change has caused a running timer to be invalid | |
---|---|
Explanation | A change in local clock has made a currently running timer to be invalid |
Recommended Action | Check the clock configuration |
%IEDGE-3-CH_INTERNAL_ERROR : Internal error in command processing — session handle=[hex] | |
---|---|
Explanation | There has been an internal error relating to CoA command processing. |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IEDGE-3-CH_REGISTER_ERROR : CoA registration error in command processing — type ‘[chars]’ | |
---|---|
Explanation | There has been an internal error relating to CoA command processing. |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
IF
%IF-3-IDB_LIST_BAD_REF_COUNT : A bad reference count was encountered in an idb list element. | |
---|---|
Explanation | A software error occurred. |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IF-2-IDB_TABLE_INIT : Malloc failed while initializing idb table | |
---|---|
Explanation | |
Recommended Action |
%IF-3-BAD_MTU : Internal error. MTU on [chars] too large or negative. Truncating from %ld to [int]. | |
---|---|
Explanation | An internal software error occurred. The system attempted to set the MTU on an interface to an invalid value. |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IF-3-BADLOCK : Invalid lock use for [chars]: [chars][chars] | |
---|---|
Explanation | Application layer code attempted to access an unlocked interface. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IF-3-BADHWUNLOCK : ([chars]) attempted to unlock [chars] ([dec]). Locked by [chars] ([dec]). | |
---|---|
Explanation | Attempt to release semaphore held by another process. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IF-3-SEMAHOG : ([chars]) could not get [chars] semaphore. Held by ([chars]). | |
---|---|
Explanation | Unable to obtain interface semaphore. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IF-4-BACKWARD_COUNTERS : Corrected for backward [chars] counters ([int] -> [int]) on [chars] | |
---|---|
Explanation | The interface specified in the message has a packet counter that has decreased in number. This condition can occur if a packet is counted and then dropped. This event was detected and corrected. |
Recommended Action | If this condition persists, copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from the error message text or from the show tech-support command output, contact your Cisco technical support representative and provide the representative with the gathered information. |
%IF-3-BADMACADDRTYPE : illegal mac address type, [dec] | |
---|---|
Explanation | This is an interal error that was recovered gracefully. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IF-4-NOBGPROCESS : Network background process not running. [chars] | |
---|---|
Explanation | A process which manages network interface background processing is not yet running, but another system process has tried to send the process a message. |
Recommended Action | An interface on the router may have missed a request to bring itself up. If that happens, it may be necessary to reset the interface using a shutdown operation and then a no shutdown. |
IFDAMP
%IFDAMP-5-UPDOWN : interface [chars] update [chars] state to [chars], interface is [chars]suppressed | |
---|---|
Explanation | dampening interface changed state. |
Recommended Action | No action is required. |
%IFDAMP-5-ZERODELAY : dampening reuse timer is updated with 0 delay time | |
---|---|
Explanation | Inconsistency of dampening reuse timer wheel |
Recommended Action | No action is required. |
IFMAP
%IFMAP-3-CAUSE_CFG : hash table not initialized | |
---|---|
Explanation | PAL interface handle to uidb hash table not initialized |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IFMGR
%IFMGR-3-IFINDEX_PERSIST_ENTRY_CORRUPT : [chars] seems to be corrupted. Trying to read [dec] size | |
---|---|
Explanation | The ifIndex-table seems to be corrupted. |
Recommended Action | Delete the ifindex-table. |
%IFMGR-3-INVALID_PERSISTENT_DATA : Invalid persistent data | |
---|---|
Explanation | Trying to write invalid persistent data |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IFMGR-3-NOVECTOR : Interface manager failed to allocate IF vector. size [dec] | |
---|---|
Explanation | The interface vector was not able to be allocated with the number of elements required—initially or resize (see size in the error message). |
Recommended Action | TBD |
%IFMGR-3-VECTOREXD : IF manager attempted to use interface [dec] outside vector range. | |
---|---|
Explanation | This message indicates that an interface with too large of an ifIndex value was attempted to be added to the IF-MGR DB. |
Recommended Action | Additional IF-MGR warning and/or error messages should accompany indication of this error. These additional messages should provide more details on the effected interface. |
%IFMGR-3-VECTORPOSUSED : IF manager attempted to add interface [dec] which was already added. | |
---|---|
Explanation | This message comes from the IF-MGR DB when it is trying to add an ifIndex value for this interface which already exists in the ifIndex DB. |
Recommended Action | TBD |
%IFMGR-4-VECTORIFSUSPECT : IF manager added interface [dec] which is unexpectedly large. | |
---|---|
Explanation | The ifIndex allocation scheme gives out sequential ifIndex values. This message comes from the IF-MGR DB when it is trying to add an ifIndex value much larger than the former greatest ifIndex value in the DB. |
Recommended Action | TBD |
%IFMGR-3-IFDB : IF manager interface database [chars] failure- [dec] | |
---|---|
Explanation | |
Recommended Action | TBD |
%IFMGR-3-IFTDB : IF manager interface table database [chars] failure- [dec] | |
---|---|
Explanation | |
Recommended Action | TBD |
%IFMGR-3-NOTYPEVECTOR : Interface manager failed to allocate IF type vector. size [dec] | |
---|---|
Explanation | The interface type vector was not able to be allocated with the number of elements required—initially or resize. |
Recommended Action | TBD |
%IFMGR-3-NOIMACP : IF manager control process failed to start | |
---|---|
Explanation | |
Recommended Action | TBD |
%IFMGR-4-NOIFINDEX : All SNMP if indices are exhausted | |
---|---|
Explanation | All SNMP MIB indices have been exhausted. Interfaces will not be able to obtain an interface index that they can use to register with the interface MIB. |
Recommended Action | Attempt a system reload. If the problem persists after the system reload, copy the message exactly as it appears on the console or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered information. |
%IFMGR-3-BADIFINDEXTABLE : The file nvram:ifIndex-table is corrupt. | |
---|---|
Explanation | The file is not in the expected format. |
Recommended Action | If possible, please delete the file. |
%IFMGR-4-NOSYNC : ifIndex not being synced between active and standby | |
---|---|
Explanation | When the standby comes up, then the tuple of ifIndex and ifDescr is synced so that when interfaces comes up they get the same ifIndex. This error happens when the interface doesn’t get the ifIndex for the given ifDescr |
Recommended Action | Inform the technical support to raise the ddts |
%IFMGR-5-RESTART : [chars] | |
---|---|
Explanation | The IF MGR process has restarted |
Recommended Action | This is an informational message. The system should recover on its own. |
%IFMGR-4-STACK_RELATIONSHIP_ADD_ERROR : [chars]: Request for creating invalid stack relationship [dec], [dec] | |
---|---|
Explanation | The IF MGR received the call to add invalid stack relationship. The higher and lower ifIndex are shown in the message. The module of the IF MGR from where this message is generated is also shown in the message |
Recommended Action | Inform the technical support to raise the ddts |
%IFMGR-3-DUP_IFINDEX : Duplicate ifIndex ([dec]) found for ifDescr [chars]; exists in ifTable for ifDescr [chars]. | |
---|---|
Explanation | Interfaces have same ifIndex in IF-MGR assigned list. The 2nd interface registered with IF-MGR will be assigned with new index |
Recommended Action | 1. No Action, if ifIndex persist is not required. 2. Reload the standby RP, if ERR msg only seen in standby RP 3. Reload the router with the proper ifindex-table and image |
%IFMGR-7-NO_IFINDEX_FILE : Unable to open [chars] [chars] | |
---|---|
Explanation | This is a informational message. This means system found no saved ifIndex information, and ifIndex is not persisted across reboots. The ifIndices will be reassigned. |
Recommended Action | 1. No Action, if ‘snmp-server ifIndex persist’ is not configured. 2. If ‘snmp-server ifindex persist’ is configured then copy the error message exactly as it appears, and report it to your technical support representative. |
IFS
%IFS-4-FILEMAX : Failed to open [chars], maximum open files [dec]) | |
---|---|
Explanation | The router has reached the maximum number of files that may be open at one time. |
Recommended Action | Close some files and try again. If this messages recurs, contact your technical support representative. |
%IFS-3-FSMAX : Failed to add [chars], maximum filesystems [dec] | |
---|---|
Explanation | The router has reached the maximum number of file systems that can be supported at one time. |
Recommended Action | Contact your technical support representative. |
%IFS-3-FSDUP : Failed to add [chars], filesystem prefix exists | |
---|---|
Explanation | A file system cound not be added because another file system exists with the same name. |
Recommended Action | Contact your technical support representative. |
%IFS-3-FS_CREATE_FAIL : Failed to create [chars] file system, [chars] | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | Call your technical support representative for assistance. |
%IFS-3-FS_CREATE_FAIL2 : Failed to create [chars] simple file system, [chars] | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | Call your technical support representative for assistance. |
%IFS-3-FS_MISSING_FUNCTIONS : ‘[chars]’ file system missing required functions, not created | |
---|---|
Explanation | Some file systems require a certain set of function to be present in order to be usable. This file sustem does not support all the mandatory functionality. |
Recommended Action | Call your technical support representative for assistance. |
%IFS-3-FS_STRUCT_ERROR : Data does not match expected internal representation | |
---|---|
Explanation | A mismatch exists between the representation of data extracted from the filesystem and the expectation of its formatting. This may occur when running in a dual-RP environment, with different IOS versions running on the two RPs. |
Recommended Action | Ensure both RPs are running the IOS same version, if running in a dual-RP environment. If not, call your technical support representative for assistance. |
IKEV2
%IKEV2-5-OSAL_INITIATE_TUNNEL : NULL | |
---|---|
Explanation | |
Recommended Action |
%IKEV2-5-RECV_CONNECTION_REQUEST : NULL | |
---|---|
Explanation | |
Recommended Action |
%IKEV2-3-NEG_ABORT : NULL | |
---|---|
Explanation | |
Recommended Action |
%IKEV2-1-SEND_COOKIE_CHALLENGE : NULL | |
---|---|
Explanation | |
Recommended Action |
%IKEV2-5-IPSEC_COLLISION : NULL | |
---|---|
Explanation | |
Recommended Action |
%IKEV2-5-SA_UP : NULL | |
---|---|
Explanation | |
Recommended Action |
%IKEV2-5-SA_DOWN : NULL | |
---|---|
Explanation | |
Recommended Action |
%IKEV2-5-SA_REJECTED_RESOURCE_LOW : NULL | |
---|---|
Explanation | |
Recommended Action |
%IKEV2-5-SA_REJECTED_LIMIT_REACHED : [chars] | |
---|---|
Explanation | |
Recommended Action |
%IKEV2-5-INCREASE_PEER_WINDOW_SIZE : NULL | |
---|---|
Explanation | |
Recommended Action |
ILPOWER
%ILPOWER-3-ILPOWER_INTERNAL_IF_ERROR : Inline Power internal error, interface [chars]: [chars] | |
---|---|
Explanation | A software check failed during Power over Ethernet (PoE) processing. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%ILPOWER-5-ILPOWER_POWER_DENY : Interface [chars]: inline power denied. Reason: [chars] | |
---|---|
Explanation | There is not enough power remaining in the switch to supply to the Power over Ethernet (PoE) port. |
Recommended Action | No action is required. |
%ILPOWER-5-ILPOWER_POWER_CDP_SHUT : Interface [chars]: inline power shut | |
---|---|
Explanation | Inline power is shut because cdp consumption power on this Power over Ethernet (PoE) port is greater than 1. allocation power or 2. hardware interface limit or 3. user configured max power or 4. available power on this switch. |
Recommended Action | No action is required. |
%ILPOWER-3-CONTROLLER_ERR : Controller error, Controller number [dec]: [chars] | |
---|---|
Explanation | An error reported or caused by the Power over Ethernet (PoE) controller is detected. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%ILPOWER-3-CONTROLLER_POST_ERR : Inline Power Feature is disabled on this switch because Power On Self Test (POST) failed on this switch. Please consult TECH support for further assistance |
|
---|---|
Explanation | An error reported or caused by the Power over Ethernet (PoE) controller is detected during POST. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%ILPOWER-3-CONTROLLER_IF_ERR : Controller interface error, [chars]: [chars] | |
---|---|
Explanation | An interface error is detected between the Power over Ethernet (PoE) controller and system. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%ILPOWER-3-CONTROLLER_PORT_ERR : Controller port error, Interface [chars]: [chars] | |
---|---|
Explanation | A port error reported by the Power over Ethernet (PoE) controller is detected. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%ILPOWER-5-POWER_GRANTED : Interface [chars]: Power granted | |
---|---|
Explanation | There is enough power available in the switch, and the switch is providing power on the interface. |
Recommended Action | No action is required. |
%ILPOWER-5-LINKDOWN_DISCONNECT : Interface [chars]: Link down disconnect | |
---|---|
Explanation | The powered device is no longer connected to the switch, or the connected powered device is being powered by an external AC power source. The switch is no longer providing power on the interface. |
Recommended Action | No action is required. |
%ILPOWER-5-IEEE_DISCONNECT : Interface [chars]: PD removed | |
---|---|
Explanation | The powered device is no longer connected to the switch, or the connected powered device is being powered by an external AC power source. The switch is no longer providing power on the interface. |
Recommended Action | No action is required. |
%ILPOWER-7-DETECT : Interface [chars]: Power Device detected: [chars] | |
---|---|
Explanation | The switch has detected the attached power device. |
Recommended Action | No action is required. |
%ILPOWER-5-INVALID_IEEE_CLASS : Interface [chars]: has detected invalid IEEE class: [dec] device. Power denied | |
---|---|
Explanation | The power device has invalid IEEE class. switch won’t powerup the device |
Recommended Action | No action is required. |
%ILPOWER-3-SHUT_OVERDRAWN : Interface [chars] is shutdown as it is consuming more than the maximum configured power ([dec]) milliwatts. |
|
---|---|
Explanation | Interface is shutdown because it is consuming more than the maximum configured power |
Recommended Action | Make sure correct power is budgeted for this interface based on the power device electrical specifications or ratings. It is recommended to change the police cutoff power to a higher value to keep the device powered on |
%ILPOWER-4-LOG_OVERDRAWN : Interface [chars] is overdrawing power. it is consuming [dec] milliwatts where as maximum configured power is ([dec]) milliwatts. |
|
---|---|
Explanation | |
Recommended Action | Make sure correct power is budgeted for this interface based on the power device electrical specifications or ratings. Otherwise you might risk overloading the switch. It is recommended to change the police cutoffpower appropriately if needed |
%ILPOWER-5-CLR_OVERDRAWN : Interface [chars] is NOT overdrawing power. it is consuming [dec] milliwatts where as maximum configured value is ([dec]) milliwatts. |
|
---|---|
Explanation | |
Recommended Action | No action is required. |
%ILPOWER-5-POLICE_POWER_INVALID : Interface [chars]: invalid power police [dec] milliwatts current [dec] mA voltage [dec] mV |
|
---|---|
Explanation | power policing current or voltage value is invalid. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%ILPOWER-5-SENSE_POWER_INVALID : Interface [chars]: invalid power sense [dec] milliwatts current [dec] mA voltage [dec] mV | |
---|---|
Explanation | power sensing current or voltage value is invalid. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%ILPOWER-4-ILPOWER_POWER_SUPPLY : PoE Power Supply [chars]: [chars] | |
---|---|
Explanation | The power supply for PoE is OIR |
Recommended Action | Make sure power supply to PoE input is inserted after removal |
%ILPOWER-4-ILPOWER_PS_ABSENCE : PoE module Power Supply not present Inline Power Feature is disabled on [chars] because Power On Self Test (POST) failed : [chars] |
|
---|---|
Explanation | The power supply for PoE expansion module is not present or not inserted properly or faulty |
Recommended Action | Make sure power supply to expansion module is inserted properly and reload the switch with PoE power supply present |
%ILPOWER-5-PWRGOOD_SPARE_PAIR : Interface [chars]: spare pair power good | |
---|---|
Explanation | Spare pair power request was successful and power is available on spare pair |
Recommended Action | No action is required. |
%ILPOWER-5-TSTART_SPARE_PAIR : Interface [chars]: spare pair power error: TSTART | |
---|---|
Explanation | spare pair tstart error has occurred, power on spare pair will not be supplied |
Recommended Action | No action is required. |
%ILPOWER-5-PGOOD_TIMEOUT_SPARE_PAIR : Interface [chars]: spare pair power good timeout error | |
---|---|
Explanation | spare pair power good timeout error has occurred, power on spare pair will not be supplied |
Recommended Action | No action is required. |
%ILPOWER-5-DET_SHORT_SPARE_PAIR : Interface [chars]: spare pair short detected | |
---|---|
Explanation | spare pair short detect error has occurred, power on spare pair will not be supplied |
Recommended Action | No action is required. |
%ILPOWER-5-DET_TIMEOUT_SPARE_PAIR : Interface [chars]: spare pair detect timeout | |
---|---|
Explanation | spare pair timeout detect error has occurred, power on spare pair will not be supplied |
Recommended Action | No action is required. |
%ILPOWER-6-SET_ILPOWER : Set power allocated to POE to [dec] for slot [dec] | |
---|---|
Explanation | The power allocated to POE has changed |
Recommended Action | No action is required. |
%ILPOWER-5-SINGLE_PAIRSET_FAULT : Interface [chars]: shutting down [chars] pairset due to fault | |
---|---|
Explanation | The dual signature PD on this port has hit a critcal fault on one pairset and hence that pairset will be shutdown |
Recommended Action | No action is required. |
%ILPOWER-5-LLDP_SHUTDOWN : Interface [chars]: PD requested shutdown for [dec] sec via LLDP MDI TLV | |
---|---|
Explanation | Inline power is removed because PD requested shutdown via LLDP MDI TLV |
Recommended Action | No action is required. |
IM through IOSD_INFRA
-
IM
-
IMGR
-
INDXOBJ
-
INFRA
-
INSTALL
-
INTERCHASSIS_REDUNDANCY
-
INTERFACE_API
-
IOMD_INFRA
-
IOSD
-
IOSD_INFRA
IM
%IM-0-UIPEER_CREATE : Failed to create user interface peer. | |
---|---|
Explanation | The system failed to create a user interface peer. |
Recommended Action | In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative. |
%IM-2-INITIALIZATION_FAILED : | |
---|---|
Explanation | Initialization of IOx Manager process failed. |
Recommended Action | Review ioxman logs taking note of the timestamp information to select specific information to review. Copy the message and other related information exactly as it appears on the console or in the system log. |
%IM-0-EVENT_LIBRARY : | |
---|---|
Explanation | An event facility initialization or maintenance function failed. This could be due to a software defect or system resource exhaustion. |
Recommended Action | In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative. |
%IM-2-INVALID_ACT_MSG : Virtualization Service[chars] | |
---|---|
Explanation | The virtualization service activate message was received, however, the data it contained could not be interpreted |
Recommended Action | Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause. |
%IM-2-INVALID_DEACT_MSG : Failed to process virtualization service deactivate message | |
---|---|
Explanation | The virtualization service deactivate message was received, however, the data it contained could not be interpreted |
Recommended Action | Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause. |
%IM-2-ALLOC_VIRT_INST_RCS : Virtualization Service[chars] | |
---|---|
Explanation | A memory allocation request failed to allocate a data structure required to activate the virtualization service. |
Recommended Action | Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause. |
%IM-2-START_FAILED : Virtualization Service[chars] | |
---|---|
Explanation | The named virtualization service failed to start. |
Recommended Action | Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause. |
%IM-2-VIRT_INST_MEMORY : Virtualization Service[chars] | |
---|---|
Explanation | The virtualization service requires physical memory in excess of the free memory available to virtualization services. |
Recommended Action | Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause. |
%IM-2-VIRT_INST_DISK : Virtualization Service[chars] | |
---|---|
Explanation | The virtualization service requires Disk Storage in excess of the Free Disk Storage available to virtualization services. |
Recommended Action | Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause. |
%IM-2-MEMORY_LIMIT : Virtualization Service[chars] | |
---|---|
Explanation | The virtualization service machine definition file is requesting more memory than the system has available for virtualization services. |
Recommended Action | Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause. |
%IM-2-VCPU_LIMIT : Virtualization Service[chars] | |
---|---|
Explanation | The virtualization service machine definition file is requesting more VCPUs than the system has reserved for virtualization services. |
Recommended Action | Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause. |
%IM-2-DISK_IMAGE_PATH : Virtualization Service[chars] | |
---|---|
Explanation | The virtualization service machine definition file contains an invalid disk image path for one of the disk devices. This may be a Harddisk, CDROM or USB storage device. |
Recommended Action | Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause. |
%IM-2-VIRT_INST_LOG_UNTHROTTLE : Failed to unthrottle the log for virtualization service [chars] | |
---|---|
Explanation | The named virtualization service had sent overwhelming sys log messages and its log had been throttled as a result, but system has failed to unthrottle it for some reason. |
Recommended Action | For debugging collect the iox-manager logs and scan them for the cause. |
%IM-2-VIRT_INST_STATE : Virtualization Service[chars] | |
---|---|
Explanation | The named virtualization service has failed. It is no longer running either because the guest OS has failed, the guest OS has shut down the machine or the emulator has failed. |
Recommended Action | An attempt at restarting the virtualization service can be made from the IOS configuration by doing a no activate/activate. For debugging collect the IOx-manager logs and scan them for the cause. |
%IM-2-FIND_VIRT_INST_ENTRY : Failed to find virtualization service with id [int] in the IOx-manager list | |
---|---|
Explanation | The virtualization service with the ID named could not be located in the IOx-manager list. |
Recommended Action | Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause. |
%IM-5-AUX : Virtualization Service[chars] | |
---|---|
Explanation | The AUX login to a virtualization service may allow the user access to system functions that may not have been tested or may interact with the system in unintended ways. Use with caution. |
Recommended Action | No action is required |
%IM-2-INVALID_UNPROV_MSG : Failed to process virtualization service unprovision message | |
---|---|
Explanation | The virtualization service unprovision message was received, however, the data it contained could not be interpreted |
Recommended Action | Enable the IOx-manager trace logs and repeat the activation followed by deactivation and then unprovision of the virtualization service. Collect the IOx-manager logs and scan them for the cause. |
%IM-2-VCPU_INVALID : Virtualization Service[chars] | |
---|---|
Explanation | The virtualization service machine definition file is requesting invalid VCPU value. |
Recommended Action | Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause. |
%IM-2-CPUSHARES_LIMIT : Virtualization Service[chars] | |
---|---|
Explanation | The virtualization service machine definition file is requesting more CPU shares than the system has available for virtualization services. |
Recommended Action | Deactivate any other virtualization services to free up CPU share resources and activate this virtualization service. If that does not address the problem, then enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and scan them for the cause. |
%IM-2-INSTALL_FAILURE : Virtualization Service[chars] | |
---|---|
Explanation | The installation of the virtualization service failed. |
Recommended Action | Enable the IOx-manager trace logs and repeat the installation of the virtualization service. Collect the IOx-manager logs and scan them for the cause. |
%IM-2-INSTALL_MEDIA_RETRY : VM install media still unavailable.[chars] | |
---|---|
Explanation | The install media was not detected. Waiting for udev to complete install media(harddisk) detection. |
Recommended Action | After IOx-manager exceeds the maximum retry limit, verify if install media (harddisk) is accessible and retry the installation again. |
%IM-2-VIRT_INST_MGMT_INTERFACE : Virtualization service [chars] has no management interface defined but it is configured in CLI. |
|
---|---|
Explanation | A management interface is configured but none is defined. |
Recommended Action | Deactivate the virtualization service, remove the management interface configuration CLI, and reactivate the virtual-service. |
%IM-2-GENERAL_FAILURE : Virtualization Service[chars] | |
---|---|
Explanation | The named virtualization service has triggered the log. Please interpret the log in the context of the virtualization services. |
Recommended Action | No action is required |
%IM-3-SDWRAP_ERR : Description: [chars], errcode: [dec] | |
---|---|
Explanation | Debug infrastructure error |
Recommended Action | Collect the IOx-manager logs and scan them for the cause. |
%IM-3-PSS_ERR : Purpose: [chars], URI: [chars], errcode: [dec] | |
---|---|
Explanation | Persistent Storage Service handling error |
Recommended Action | Collect the IOx-manager logs and scan them for the cause. |
%IM-3-PSS_SNAPSHOT_ERR : Source URI: [chars], Destination URI: [chars], errcode: [dec] | |
---|---|
Explanation | Persistent Storage Service snapshot error |
Recommended Action | Collect the IOx-manager logs and scan them for the cause. |
%IM-2-NETWORK_CONFIG_ERROR : Virtualization Service[chars] | |
---|---|
Explanation | A network configuration error has been detected for the named virtualization service. |
Recommended Action | No action is required |
%IM-2-INSTALL_LOG : [chars] [chars] [chars] [chars] | |
---|---|
Explanation | The installation log of the named virtualization service, is to provide more information about long running operation, that could affect the control of CLI |
Recommended Action | No action is required |
%IM-2-UPGRADE_LOG : [chars] [chars] [chars] [chars] | |
---|---|
Explanation | The upgrade log of the named virtualization service, is to provide more information about long running operation, that could affect the control of CLI |
Recommended Action | No action is required |
%IM-2-INSTALL_STATE : [chars] ‘[chars]'[chars] [chars] | |
---|---|
Explanation | The installation state of the named virtualization service has changed as notified by IOx-manager. |
Recommended Action | In the failed case, check IOx-manager’s logs for the cause of the failure. In the successful case, this notification can be ignored. |
%IM-2-UNINSTALL_ALL_VMS : All Virtualization Services are being uninstalled [chars][chars] [chars] | |
---|---|
Explanation | All virtualization services are being uninstalled by IOx-manager. |
Recommended Action | Examine the reason given as to why all virtualization services are being uninstalled for more information. If the reason indicated is due to some error condition, check IOx-manager’s logs for the cause of the failure. |
%IM-2-ACTIVATION_STATE : [chars] ‘[chars]’ [chars] [chars] | |
---|---|
Explanation | The activation state of the named virtualization service has changed as notified by IOx-manager. |
Recommended Action | In the failed case, check IOx-manager’s logs for the cause of the failure. In the successful case, this notification can be ignored. |
%IM-4-WATCHDOG_TIMER : [chars] ‘[chars]’ [chars] [chars] | |
---|---|
Explanation | The watchdog timer configured for the named virtual service has expired. |
Recommended Action | Check any logs produced by the virtualization service to determine the cause. |
%IM-2-HA_SYNC_ERR : [chars] ‘[chars]’ [chars] | |
---|---|
Explanation | The ha-sync persistent storage disk for the virtualization service cannot be watched for sync to standby RP. |
Recommended Action | Collect the IOx-manager logs and scan them for the cause. |
%IM-2-DEACT_FOR_ISSU : [chars] Max ([int]s) | |
---|---|
Explanation | An ISSU event is pending. Any active VMs will be automatically deactivated to allow ISSU preprocessing to validate the environment. Any ISSU-deactivated VMs will be automatically restarted if the ISSU is cancelled. |
Recommended Action | None. Allow the ISSU to continue and the VMs will restart when the ISSU completes or cancel the ISSU and IOx-manager will automatically |
%IM-2-RESET_FORCE : Virtualization Services non-recoverable reset command processed | |
---|---|
Explanation | A ‘virtualization service reset force’ command has been entered and processed. This action initiates a cleanup of last resort. Occasionally a VM will get into an unrecoverable state that prevents it from activating but also from uninstalling. This is a rare event but when it happens the only resort may be to remove the .conf control file and reboot, which forces a cleanup of all previously installed VM files and artifacts. Note that once this command is used, current VMs are considered to be in an unstable or unpredictable state, and all future install, uninstall, upgrade, and activation commands will be blocked. |
Recommended Action | Once the command is entered and accepted, there is no recourse but to restart the system. |
%IM-2-MOVE_STATE : [chars] ‘[chars]’ [chars] [chars] | |
---|---|
Explanation | The move of the core or log file of the named virtualization service has as been successful or failed as notified by IOx-manager. |
Recommended Action | In the failed case, check IOx-manager’s logs for the cause of the failure. In the successful case, this notification can be ignored. |
%IM-2-RSYNC_STATE : [chars] [chars] [chars] [chars] | |
---|---|
Explanation | IOx-manager tries to remote sync the virtual-instance configuration file and the OVA repository to all online nodes. If rsync fails even after consecutive retries, this notification would be raised. |
Recommended Action | In the failed case, check IOx-manager’s logs for the cause of the failure. Check for the rsync error code and root cause the same. |
%IM-2-HA_SYNC_THREAD_STATE : HA remote sychronize thread has failed and exited. | |
---|---|
Explanation | IOx-manager tries to remote sync the OVA repository to all online nodes using a separate thread. If that thread fails, this notification would be raised. |
Recommended Action | In the failed case, check IOx-manager’s logs for the cause of the failure. Check for the pthread error msg and root cause the same. |
%IM-2-HA_STATE : [chars] [chars] [chars] [chars] | |
---|---|
Explanation | IOx-manager tries to detect the role/slot of various nodes on HA events from the platform. If any of those event callbacks fail, this notification would be raised. |
Recommended Action | In the failed case, check IOx-manager’s logs for the cause of the failure. Check for the HA event error msg and root cause the same. |
%IM-2-HA_SWITCHOVER_STATE : [chars] [chars] [chars] [chars] | |
---|---|
Explanation | IOx-manager HA switchover state related messages for a virtual-service whilst it is being recovered on newly active RP after a HA switchover. |
Recommended Action | In the failed case, check IOx-manager’s logs for the cause of the failure. Check for the HA event error msg and root cause the same. |
%IM-4-HA_SYNC_NEEDED : If using the guest shell, please use ‘guestshell sync’ if you want to preserve state on standby in case of supervisor switchover |
|
---|---|
Explanation | Message notifying user that he needs to manually synchronize the Virtualization service contents to standby supervisor in order to preserve these contents in case of a supervisor switchover. Currently only applicable to the guest shell |
Recommended Action | User can type the ‘guestshell sync’ command on active supervisor to synchronize it’s contents to the standby supervisor if desired. |
%IM-2-RESIZE_OPER_STATE : Virtualization service ‘[chars]’ [chars][chars] to ‘[int]’ [chars] | |
---|---|
Explanation | IOx-manager attempts to resize various VM parameters like rootfs size, CPU share, memory if requested by user. Success/failure status messages for these resize operations are communicated by this syslog. |
Recommended Action | In the failed case, check IOx-manager’s logs for the cause of the failure. Check for the HA event error msg and root cause the same. |
%IM-2-GUESTSHELL_ENABLED : The guest shell has been enabled. The command ‘[chars]’ may be used to access it, ‘[chars] destroy’ to remove it. |
|
---|---|
Explanation | Informs the user that the guest shell virtualization service has been enabled (which is done by default). |
Recommended Action | The user may use or remove the guest shell with the commands specified. |
%IM-5-PERMISSION_DENIED : Virtualization Service ‘[chars]’ is not owned by client IOSd | |
---|---|
Explanation | An attempt was made to modify a virtual-service that is not owned by by the client. The request was rejected. |
Recommended Action | No action is required. |
%IM-2-IOX_INST_CRIT : IOX SERVICE [chars] LOG: [chars] | |
---|---|
Explanation | The named virtual service has triggered the log. Please interpret the log in the context of the virtual services. |
Recommended Action | No action is required |
%IM-3-IOX_INST_ERR : IOX SERVICE [chars] LOG: [chars] | |
---|---|
Explanation | The named IOX service has triggered the log. Please interpret the log in the context of the IOX services. |
Recommended Action | No action is required |
%IM-4-IOX_INST_WARN : IOX SERVICE [chars] LOG: [chars] | |
---|---|
Explanation | The named IOX service has triggered the log. Please interpret the log in the context of the IOX services. |
Recommended Action | No action is required |
%IM-5-IOX_INST_NOTICE : IOX SERVICE [chars] LOG: [chars] | |
---|---|
Explanation | The named IOX service has triggered the log. Please interpret the log in the context of the IOX services. |
Recommended Action | No action is required |
%IM-6-IOX_INST_INFO : IOX SERVICE [chars] LOG: [chars] | |
---|---|
Explanation | The named IOX service has triggered the log. Please interpret the log in the context of the IOX services. |
Recommended Action | No action is required |
%IM-7-IOX_INST_DEBUG : IOX SERVICE [chars] LOG: [chars] | |
---|---|
Explanation | The named IOX service has triggered the log. Please interpret the log in the context of the IOX services. |
Recommended Action | No action is required |
%IM-2-IOX_INST_LOG_UNTHROTTLE : Failed to unthrottle the log for IOX service [chars] | |
---|---|
Explanation | The named IOX service had sent overwhelming sys log messages and its log had been throttled as a result, but system has failed to unthrottle it for some reason. |
Recommended Action | For debugging collect the ioxman logs and scan them for the cause. |
%IM-6-IOX_RECONCILE_INFO : App-hosting application reconcile process [chars] | |
---|---|
Explanation | Indicates stage of reconcile (application recovery) process. |
Recommended Action | No action is required |
%IM-6-IOX_START_INFO : [chars] cannot be started because it is not installed | |
---|---|
Explanation | Indicates starting an app before installation. |
Recommended Action | No action is required |
%IM-6-IOX_START_SUCCESS : [chars] is in RUNNING state | |
---|---|
Explanation | Indicates starting an app after installation. |
Recommended Action | No action is required |
%IM-6-IOX_START_FAIL : [chars] failed to start | |
---|---|
Explanation | Indicates starting an app after installation. |
Recommended Action | No action is required |
%IM-6-START_MSG : app-hosting: [chars] | |
---|---|
Explanation | Message for starting an app. |
Recommended Action | In the failed case, check Ioxman’s trace log for the cause of the failure. In the successful case, this notification can be ignored. |
%IM-6-INSTALL_MSG : app-hosting: [chars] | |
---|---|
Explanation | Message for installing an app. |
Recommended Action | In the failed case, check Ioxman’s trace log for the cause of the failure. In the successful case, this notification can be ignored. |
%IM-6-ACTIVATE_MSG : app-hosting: [chars] | |
---|---|
Explanation | Message for activating an app. |
Recommended Action | In the failed case, check Ioxman’s trace log for the cause of the failure. In the successful case, this notification can be ignored. |
%IM-6-DEACTIVATE_MSG : app-hosting: [chars] | |
---|---|
Explanation | Message for deactivating an app. |
Recommended Action | In the failed case, check Ioxman’s trace log for the cause of the failure. In the successful case, this notification can be ignored. |
%IM-2-IOX_ENABLEMENT : IOX is ready. | |
---|---|
Explanation | Message for IOX enablement. |
Recommended Action | No action is required |
%IM-6-UPGRADE_MSG : app-hosting: [chars] | |
---|---|
Explanation | Message for upgrading an app. |
Recommended Action | In the failed case, check Ioxman’s trace log for the cause of the failure. In the successful case, this notification can be ignored. |
%IM-6-VERIFICATION_MSG : app-hosting: [chars] | |
---|---|
Explanation | Message for signature verification |
Recommended Action | In the failed case, check Ioxman’s trace log for the cause of the failure. In the successful case, this notification can be ignored. |
IMGR
%IMGR-0-FIPS_FMFP_BYPASS_TEST : NIST bypass test failed for [chars]. | |
---|---|
Explanation | Forwarding Manager IPsec component detected a discrepancy when adding or deleting a security sensitive object. This could be due to a hardware or software resouce limitation or a software defect. |
Recommended Action | Check the logs for information on the relevant object download states. Remove the object or a parent object in question. If the problem persists reboot the forwarding processor (ESP). |
%IMGR-6-FIPS_FMFP_CRNG_TEST : continuous [chars]approved RNG test failed. | |
---|---|
Explanation | Forwarding Manager IPsec component detected two identical random number sequences. This could be due to a hardware mulfunction or a software defect. |
Recommended Action | If the problem persists reboot the forwarding processor (ESP). |
%IMGR-6-FIPS_FMFP_OLAP_TEST : FIPS-approved RNG key seed and state overlap. | |
---|---|
Explanation | Forwarding Manager IPsec component detected an overlap in FIPS-approved RNG key seed and state. This could be due to a hardware mulfunction or a software defect. |
Recommended Action | If the problem persists reboot the forwarding processor (ESP). |
%IMGR-6-FIPS_FMFP_KAT_TEST : power up cryptographic self-test didnot run to completion: [chars]. | |
---|---|
Explanation | Forwarding Manager power up known answer self-test (KAT) failed. This could be due to a hardware malfunction or a software defect. |
Recommended Action | If using ipsec, reboot the forwarding processor (ESP). |
%IMGR-0-FIPS_CPP_CLIENT_BYPASS_TEST : CPP Client FIPS bypass test failed for [chars]. | |
---|---|
Explanation | Forwarding Manager CPP client IPSEC bypass test failed. This could be due to a hardware malfunction or a software defect. |
Recommended Action | If the problem persists reboot the forwarding processor (ESP). |
%IMGR-6-FIPS_FMFP_N2_ERR_FAIL : Cryptographic coprocessor non-critical failure: [chars]. | |
---|---|
Explanation | Cryptographic coprocessor non-critical operation failed. If the problem persists reboot the forwarding processor(ESP) |
Recommended Action | If the problem persists reboot the forwarding processor (ESP). |
%IMGR-0-FIPS_FMFP_N2_SEVERE_ERR_FAIL : Cryptographic coprocessor severe failure: [chars]. | |
---|---|
Explanation | Cryptographic coprocessor critical operation failed. Further data processing on ESP is halted |
Recommended Action | forwarding processor (ESP) is rebooted automatically. no action needed |
%IMGR-6-FMFP_KAT_TEST_RESULT : crypto self-test for algorithm: ([chars] … passed). | |
---|---|
Explanation | Forwarding Manager power up known answer self-test (KAT) success. This is not an error message |
Recommended Action | No action needed. |
%IMGR-6-FMFP_IPSEC_MIN_MTU_INFO : MTU smaller than minimum IPSec MTU, [chars]. | |
---|---|
Explanation | Minimum MTU supported by crypto processor is 256B, MTU lower than 256B is set to 256B |
Recommended Action | No action needed |
%IMGR-6-FMFP_IPSEC_UNSUPPORTED_CIPHER : Cipher [chars] is not supported on this ESP. | |
---|---|
Explanation | This ESP does not support this IPSec cipher |
Recommended Action | No action needed |
%IMGR-6-FMFP_IPSEC_CRYPTO_CTRL_THROTTLED : IPsec Control Plane Overload Crypto Device: [chars]. | |
---|---|
Explanation | This ESP crypto device is overloaded. |
Recommended Action | May need to config platform ipsec control-plane medium|heavy |
%IMGR-6-FMFP_CRYPTO_DEVICE_BUSY : All Crypto Device cores are busy with data packets. | |
---|---|
Explanation | All ESP crypto device are busy. |
Recommended Action | May need to lower crypto traffic rate. |
INDXOBJ
%INDXOBJ-3-INTERRUPT : index object routine [chars] called from interrupt context | |
---|---|
Explanation | inappropriate index object routine called from interrupt routine. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%INDXOBJ-3-ADD_ERROR : index add for [chars] failed: [chars] | |
---|---|
Explanation | index object routine error |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
INFRA
%INFRA-3-INVALID_GPM_ACCESS : Invalid GPM [chars] at [hex] HAL start [hex] HAL end [hex] INFRA start [hex] INFRA [hex] NET [hex], MSGDEF_LIMIT_MEDIUM |
|
---|---|
Explanation | Processing packet went beyond valid packet data, packet was possibly invalid, ppe info and encrypted pkt dump follow |
Recommended Action | LOG_STD_ACTION |
%INFRA-3-INVALID_GPM_ACCESS_INFO : [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] |
|
---|---|
Explanation | Registers associated with previous exception error |
Recommended Action | LOG_STD_ACTION |
%INFRA-3-INVALID_GPM_ACCESS_DATA : | |
---|---|
Explanation | Packet associated with previous exception error The packet data has been encrypted |
Recommended Action | LOG_STD_ACTION |
INSTALL
%INSTALL-5-OPERATION_START_INFO : Started [chars] package [chars] | |
---|---|
Explanation | This message is used to indicate the beginning of operations. |
Recommended Action | No action required. This is not an error, it is an indication that the system is starting the operation. |
%INSTALL-5-OPERATION_COMPLETED_INFO : Completed [chars] package [chars] | |
---|---|
Explanation | This message is used to indicate the completion of operations. |
Recommended Action | No action required. This is not an error, it is an indication that the system completed the operation. |
%INSTALL-3-OPERATION_ERROR_MESSAGE : Failed to [chars] package [chars], Error: [chars] | |
---|---|
Explanation | This message is used to inform the failure reason. |
Recommended Action | Please refer to the error message to analyze the cause of failure. |
%INSTALL-5-INSTALL_START_INFO : Started [chars] [chars] [chars] | |
---|---|
Explanation | This message is used to indicate the beginning of install operations. |
Recommended Action | No action required. This is not an error, it is an indication that the system is starting this operation. |
%INSTALL-5-INSTALL_COMPLETED_INFO : Completed [chars] [chars] [chars] | |
---|---|
Explanation | This message is used to indicate the completion of install operations. |
Recommended Action | No action required. This is not an error, it is an indication that the system completed this operation. |
%INSTALL-3-INSTANT_ERROR_MESSAGE : Error Message: [chars] | |
---|---|
Explanation | This message is used to send a instant erorr message. |
Recommended Action | No action required. |
%INSTALL-5-INSTALL_AUTO_ABORT : Install auto abort timer expired: initiating abort | |
---|---|
Explanation | An install operation has been aborted because the auto abort timer has expired. |
Recommended Action | No user action is needed. If you want to commit the ISSU upgrade, redo the upgrade. Otherwise, this is an informational message only. |
%INSTALL-5-INSTALL_AUTO_ABORT_TIMER_PROGRESS : Install auto abort timer will expire in [dec] seconds | |
---|---|
Explanation | An install operation will be aborted after specified seconds of time. |
Recommended Action | No user action is needed. If you want to commit the ISSU upgrade, redo the upgrade. Otherwise, this is an informational message only. |
INTERCHASSIS_REDUNDANCY
%INTERCHASSIS_REDUNDANCY-4-STDBY_PRESENT : Removal of standby RP in location [chars] is recommended for inter-chassis redundancy configuration |
|
---|---|
Explanation | Removal of standby RP from the chassis is recommended for inter-chassis redundancy |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
INTERFACE_API
%INTERFACE_API-4-BADSWIDB : [chars] may not be referencing the correct swidb | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%INTERFACE_API-4-BADPAKINPUT : pak->if_input is not initialized | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%INTERFACE_API-1-NAMESTRTOOLONG : Interface name [chars].[int] exceeded maximum allowed length [dec] | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%INTERFACE_API-3-NOADDSUBBLOCK : The [chars] subblock named [chars] was not added to [chars] | |
---|---|
Explanation | A software error has occured, this message is displayed when IDB subblocks cannot be added. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%INTERFACE_API-3-INVALIDSUBBLOCKPARAMETERS : Invalid subblock parameters for [chars] were supplied. | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show idb and show tech-support commands to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit BUG_TOOLKIT . If you still require assistance, open a case with the Technical Assistance Center via the Internet TAC_CASE_OPEN , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%INTERFACE_API-3-SUBNUMDBERR : subnum [hex] error in [chars] | |
---|---|
Explanation | A software error has occured, this message is displayed when a problem has occured with a sub_number db. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%INTERFACE_API-1-NOMORESWIDB : No more SWIDB can be allocated, maximum allowed [dec] | |
---|---|
Explanation | No more Interfaces can be created because the maximum number of SWIDB allowed for this platform has been reached |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%INTERFACE_API-1-NOMORE_HASWIDBS : No more IDBS can be created. The maximum allowed numbers, [int], has been reached on Standby Please force redundancy mode to RPR if full Active Capacity, [int], is needed |
|
---|---|
Explanation | No more Software IDB numbers can be Created. The maximum allowed numbers has been reached for this High Available System. |
Recommended Action |
%INTERFACE_API-1-NOMOREHWIDBNUMBERS : No more hardware IDB numbers can be issued. The maximum allowed numbers, [dec], has been reached for this platform. |
|
---|---|
Explanation | No more hardware IDB numbers can be issued. The maximum allowed numbers has been reached for this platform. |
Recommended Action | In addition to the following, copy the information from show idb. LOG_STD_ACTION |
%INTERFACE_API-1-NOMORESWIDBNUMBERS : No more software IDB numbers can be issued. The maximum allowed numbers, [dec], has been reached for this platform. |
|
---|---|
Explanation | No more software IDB numbers can be issued. The maximum allowed numbers has been reached for this platform. |
Recommended Action | In addition to the following, copy the information from show idb. LOG_STD_ACTION |
%INTERFACE_API-4-BADPAKOUTPUT : pak->if_output is not initialized on interface [chars] | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%INTERFACE_API-4-BADPOINTER : Function [chars] detected an invalid [chars] pointer of %08lX, ignoring | |
---|---|
Explanation | A software error has occurred, this message is displayed when an invalid pointer is detected. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%INTERFACE_API-3-NODESTROYSUBBLOCK : The [chars] subblock named [chars] was not removed | |
---|---|
Explanation | A software error has occured, this message is displayed when IDB subblocks cannot be removed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%INTERFACE_API-3-CANNOTGETMTU : Error [dec] received while getting MTU: [chars]. Using default [int] | |
---|---|
Explanation | A software error has occurred while attempting to retrieve the MTU value from the interface. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%INTERFACE_API-3-NOSUBBLOCK : [chars] subblock does not exist on interface [chars] | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%INTERFACE_API-4-TBLERROR : A error occurred while using the Index Table utility for [chars]. | |
---|---|
Explanation | A software error has occurred; this message is displayed when an Index table feature could not be used successfully. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%INTERFACE_API-3-BADIDBSTATUSCHANGECALL : Invalid function call at interrupt level. | |
---|---|
Explanation | An internal function was illegally called at interrupt level. This error might be caused by incorrectly coded creation or deletion of an interface, or during an OIR operation. |
Recommended Action | Perform a search of the Bug Toolkit, BUG_TOOLKIT . If you still require assistance, copy the error message exactly as it appears on the console or in the system log. Issue the show tech command and copy the output. If you performed any actions before the error message appeared, make a note of this. Open a case with the Technical Assistance Center via the Internet TAC_CASE_OPEN , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%INTERFACE_API-3-IFNUMTOIDBERROR : Error occurred while using the ifnum to idb table for interface [chars], if number [dec], during [chars] |
|
---|---|
Explanation | A software error has occurred. This message is displayed when an operation on the if_number to idb mapping table could not be performed successfully. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%INTERFACE_API-3-HWIDBQREENTRANT : [chars] in progress of being inserted/removed, ignoring new request to [chars] | |
---|---|
Explanation | A software error has occurred while attempting to insert or remove the interface into the system as there’s already another attempt in progress to insert or remove this interface. The first attempt must complete before a new attempt can be started. The user should retry this operation at a later time. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOMD_INFRA
%IOMD_INFRA-4-BADPOINTER : Function [chars] detected an invalid [chars] pointer of %08lX, ignoring | |
---|---|
Explanation | A software error has occurred, this message is displayed when an invalid pointer is detected. |
Recommended Action | Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case, or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOMD_INFRA-3-IPCSENDFAIL : IOMD failed to send a message [chars] reason: [chars] | |
---|---|
Explanation | IOMD failed to send message to the RP |
Recommended Action | Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case, or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOMD_INFRA-3-IPCALLOCFAIL : Failed to allocate IPC buffer [chars] | |
---|---|
Explanation | The IM failed to allocate a buffer for communication with RSP |
Recommended Action | Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case, or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOMD_INFRA-6-TDLMSG_INCOMPATIBLE : Failed to copy message [chars] to buffer, not allowed for current domain. | |
---|---|
Explanation | Failure to marshal a message indicates an incompatibility with the intended recipient. |
Recommended Action | Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case, or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOMD_INFRA-3-INVALID_SLOT_NUM : An invalid slot number is specified in one of the internal APIs. slot=[dec] max_slot=[dec] | |
---|---|
Explanation | Invalid slot number to find the TDL domain |
Recommended Action | Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case, or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOMD_INFRA-3-INVALID_BAY_NUM : An invalid bay number is specified in one of the internal APIs. bay=[dec] max_bay=[dec] | |
---|---|
Explanation | Invalid bay number to find the TDL domain |
Recommended Action | Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case, or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOMD_INFRA-4-INTR_OVER_LIMIT : IOMd main thread disabled interrupt for [int] msec. | |
---|---|
Explanation | IOMd main thread process disabled interrupt too long |
Recommended Action | Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case, or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOMD_INFRA-3-INTR_EVENT : IOMd fast thread event ([dec]). | |
---|---|
Explanation | IOMd fast thread event |
Recommended Action | Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case, or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOMD_INFRA-3-I2C_WRITE : An I2C write has failed because [chars] | |
---|---|
Explanation | An I2C write has failed. This could be due to a hardware or software defect. |
Recommended Action | Note the time of the error message and examine the logs for I2C errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative. |
%IOMD_INFRA-3-I2C_READ : An I2C read has failed because [chars] | |
---|---|
Explanation | An I2C read has failed. This could be due to a hardware or software defect. |
Recommended Action | Note the time of the error message and examine the logs for I2C errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative. |
%IOMD_INFRA-3-LINECARDDIAGSFAILED : Module [chars] in Slot [dec] failed online diagnostics. Please use ‘show post’ for more details |
|
---|---|
Explanation | Online Diag has failed. This could be due to a hardware or software defect. |
Recommended Action | Note the time of the error message and examine the logs for errors. If the logs provide information about a correctable problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative. |
IOSD
%IOSD-3-BIPC_REJECT : Could not accept ipc connection: [chars] | |
---|---|
Explanation | This error occurs if shell-manager has denied an ipc connection request from IOS. |
Recommended Action | Check the connection request parameters. |
%IOSD-3-TDL_PROPERTIES : Could not set message properties for connection: [chars] | |
---|---|
Explanation | This error occurs if shell-manager is unable to set message properties for the IOS-sman connection |
Recommended Action | Check the connection request parameters. |
IOSD_INFRA
%IOSD_INFRA-6-IFS_DEVICE_OIR : Device [chars] [chars] | |
---|---|
Explanation | USB inserted/removed |
Recommended Action | No action is required. |
%IOSD_INFRA-3-IFS_DEVICE_DETECT_FAIL : Device [chars] [chars] | |
---|---|
Explanation | USB detection failed |
Recommended Action | USB Insertion could not be handled completely. Device needs to be removed and re-inserted |
IOSXE_APS through IOSXE_FMANRP_CCE
-
IOSXE_APS
-
IOSXE_CSLIFS
-
IOSXE_CXSC
-
IOSXE_DNS
-
IOSXE_EPA
-
IOSXE_ETHERCHAN
-
IOSXE_EZMENU
-
IOSXE_FMANRP
-
IOSXE_FMANRP_ADJ
-
IOSXE_FMANRP_CCE
IOSXE_APS
%IOSXE_APS-3-GROUP_CONFIG_FAIL : Group change for interface [chars] Group [dec] failed | |
---|---|
Explanation | Group change for interface has failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_APS-3-CONFIG_FAIL : config change for interface [chars] Group [dec] failed | |
---|---|
Explanation | config for an interface to forwarding plane has failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_APS-3-FLOWIDDELETIONFAILED : Deletion of APS flow ID with manager failed for interface [chars] group [dec] | |
---|---|
Explanation | An unexpected condition has occurred that deletion of APS flow ID. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_APS-3-FLOWIDALLOCFAILED : Allocation of APS flow ID with manager failed for interface [chars] group [dec] | |
---|---|
Explanation | An unexpected condition has occurred that allocation of APS flow ID. failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_APS-3-PAIR_CONFIG_FAIL : Pair config for interface [chars] Group [dec] failed | |
---|---|
Explanation | Pair config for interface has failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_APS-3-CCCONFIGFAILED : Pair config for interface [chars] Group [dec] failed | |
---|---|
Explanation | Pair config for interface has failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_APS-3-FLOWCONFIGTOCCFAILED : Flow id to cc for interface [chars] Group [dec] failed | |
---|---|
Explanation | Flow id to cc for an interface has failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_APS-3-DOWNLOADFAIL : Unable to download [chars] message to [chars] | |
---|---|
Explanation | An unexpected condition has occurred which resulted in a configuration not being sent to the reported process. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_CSLIFS
%IOSXE_CSLIFS-3-ERROR_SETTING : Error setting default file system ([dec]) | |
---|---|
Explanation | There is an error happened after calling function ifs_set_default_directory |
Recommended Action | Check the csl filesystem |
IOSXE_CXSC
%IOSXE_CXSC-3-ALLOC : Failed to allocate message for proposition | |
---|---|
Explanation | When attempting to program the dataplane with a CXSC proposition object, there was no enough memory to allocate the message. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_CXSC-3-MESSAGE : Failed to send message for proposition | |
---|---|
Explanation | When the proposition was being prepared for sending to the data plane, there was an error. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_CXSC-3-ACTION : Unknown proposition action ([dec]) | |
---|---|
Explanation | When the proposition was being sent to the data plane, the action was unknown error. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_CXSC-3-BAD_PROPOSITION : Proposition obj corrupt | |
---|---|
Explanation | When the proposition was being sent to the data plane, the object itself is corrupt. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_CXSC-3-BAD_SUMMARY : Summary obj corrupt | |
---|---|
Explanation | When the proposition summary was being sent to the data plane, the object itself is corrupt. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_CXSC-4-DUAL_RP_UNSUPPORTED : Dual RPs are not supported in conjunction with CXSC | |
---|---|
Explanation | CXSC is not supported in a dual RP environment. To resolve this warning, either unconfigure CXSC or remove the redundant Route Processor. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_CXSC-3-RF_INIT : Failed to initialize CXSC Redundancy Facility client | |
---|---|
Explanation | An unexpected condition occurred where the CXSC Redundancy Facility failed to initialize. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_CXSC-3-STILE_ACTIVATE : Failed to activate NBAR classification: ([dec]) | |
---|---|
Explanation | An unexpected condition occurred where the CXSC NBAR protocol classification failed to activate. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_CXSC-3-STATISTICS_ALLOCATION : Unable to allocate space for statistics | |
---|---|
Explanation | During initialization, there was failure in the allocation of the memory to gather the statistics. It is non fatal, but after seeing this message, the CXSC subsystem will not be able to gather statistics. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_CXSC-3-BAD_PROTOCOLPACK : Invalid Protocol Pack object | |
---|---|
Explanation | When the Protocol Pack was being sent to the data plane, the object’s contents were invalid. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_CXSC-3-FILESYSTEM_ERR : FileSystem Error ([chars]): Unable to Copy File from [chars] to [chars] | |
---|---|
Explanation | Unable to copy the NBAR Protocol Pack File to the file system for subsequent loading. The system will revert to the previously loaded Protocol Pack. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_CXSC-3-INSUFFICIENT_ALLOC_IOSXE_VER : Insufficent memory allocated for IOSXE version String | |
---|---|
Explanation | The input IOSXE Version String has insufficient memory to hold the IOSXE Version. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_CXSC-3-INSUFFICIENT_ALLOC_NBAR_VER : Insufficent memory allocated for NBAR Engine Version String | |
---|---|
Explanation | The input NBAR Engine Version string has insufficient memory to hold the NBAR Engine Version. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_CXSC-3-PLATFORM_TYPE : Unrecognised platform type. CPU ID [dec] | |
---|---|
Explanation | The platform that the cxsc service is being installed on is not recognised. The most likely cause is that this platform is not supported. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_DNS
%IOSXE_DNS-3-UPDATE_FAILED : Update resolv.conf, vrf [chars], rc [dec] | |
---|---|
Explanation | An unexpected condition has occurred while updating the DNS file |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_DNS-3-VRF_FAILED : Operation ([chars]) on /etc/netns/[chars], rc [dec] | |
---|---|
Explanation | An unexpected condition has occurred while updating the DNS directory |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_EPA
%IOSXE_EPA-3-CREATION_FAILURE : slot=[dec] subslot=[dec], spa_type=[hex], lc_type=[hex]. | |
---|---|
Explanation | Failed to create a SPA object. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_EPA-3-ACT2_AUTHENTICATION_FAILURE : slot=[dec] subslot=[dec], spa_type=[hex], lc_type=[hex]. | |
---|---|
Explanation | ACT2 dev authentication Failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_EPA-3-NULL_EPASENSOR_PTR : | |
---|---|
Explanation | Pointer to a DEVSENSOR object is NULL. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_EPA-3-NULL_PORT_PTR : | |
---|---|
Explanation | Pointer to a PORT object is NULL. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_EPA-3-NULL_DEVPSEQ_PTR : | |
---|---|
Explanation | Pointer to a DEVPSEQ object is NULL. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_EPA-3-NULL_DEVOBJ_PTR : | |
---|---|
Explanation | Pointer to a DEVOBJ object is NULL. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_EPA-3-NULL_FPGA_PTR : | |
---|---|
Explanation | Pointer to a FPGA object is NULL. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_EPA-3-NULL_EPA_PTR : | |
---|---|
Explanation | Pointer to an EPA object is NULL. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_EPA-3-NULL_VSC_PHY_INFO_PTR : | |
---|---|
Explanation | Pointer to a VSC PHY INFO object is NULL. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_EPA-3-NULL_VFT : | |
---|---|
Explanation | Pointer to a DEVSENSOR object is NULL. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_EPA-3-UNSUPPORTED_XCVR : Transceiver type [chars] is not allowed on spa [chars], port [dec], | |
---|---|
Explanation | This transceiver is not allowed on the SPA |
Recommended Action | Consult the documentation and ensure supported transceivers are plugged into the SPA |
%IOSXE_EPA-3-AUTONEG_CFG_ERR : interface [chars] autoneg state ‘[chars]’ is incompatible with transciever. Remove ‘[chars]’ to allow the transceiver. |
|
---|---|
Explanation | Autoneg Config is not compatible. Remove autoneg config on the interface to allow the transceiver |
Recommended Action | Remove the negotiation auto config or reinsert the previously enabled transceiver. |
%IOSXE_EPA-3-XCVR_EC_BWMISMATCH : Trasnsceiver bandwidth is incompatible with Port-channel[dec] allowed bandwidth. Remove ‘channel-group [dec]’ config for interface [chars] to allow the transceiver |
|
---|---|
Explanation | The interface port into which the transceiver is inserted is part of a Port-channel. The Port-channel has member links whose bandwidth doesn’t match with the inserted transceier’s bandwidth. Since, port-channel cannot allow heterogenous bandwidth links, this transceiver is not allowed in to the port. |
Recommended Action | Remove the channel-group config for the port where transceiver is inserted or insert a transceiver whose bandwidth is compatible with the port-channel bandwidth |
%IOSXE_EPA-3-XCVR_PROHIBIT : Transceiver is prohibited to come online for interface [chars] | |
---|---|
Explanation | XCVR is prohibited on the interface |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_ETHERCHAN
%IOSXE_ETHERCHAN-6-LINK_MTU : Interface [chars] MTU set to port-channel [chars] MTU [dec] | |
---|---|
Explanation | The MTU for the interface mentioned in the message is changed to match the MTU configured on the port channel interface |
Recommended Action | No action is required. |
%IOSXE_ETHERCHAN-3-LINK_MTU_FAIL : Failure in changing MTU of interface [chars] to port-channel [chars] MTU | |
---|---|
Explanation | The MTU for the interface mentioned in the message cannot be changed to match the MTU configured on the port channel interface |
Recommended Action | Remove the link mentioned in the message from the port-channel group |
IOSXE_FMANRP
%IOSXE_FMANRP-4-MSGDISPATCHNULL : TDL messages NULL from IOS. | |
---|---|
Explanation | An unexpected condition has occurred while IOS trying to dispatch the TDL message handler functions for received TDL messages from Forwarding Manager. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP-4-MSGDISPATCH : Unable to dispatch received TDL message ‘[chars]’ from Forwarding Manager. LUID: [chars] | |
---|---|
Explanation | An unexpected condition has occurred while IOS trying to dispatch the TDL message handler functions for received TDL messages from Forwarding Manager. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP-4-MSGIPCERR : Unable to process received IPC messages from Forwarding Manager, error: [chars]. | |
---|---|
Explanation | An unexpected condition has occurred while IOS trying to process received IPC message from Forwarding Manager. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP-3-EPOCHTDLMSGMARSHAL : Failed to copy epoch TDL message to IPC buffer, epoch number [dec] | |
---|---|
Explanation | This operation to build a TDL messages for epoch message has failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP-3-MSGMARSHALERR : Unable to copy IPC messages into transport buffer. Message: [chars] | |
---|---|
Explanation | An unexpected condition has occurred while IOS trying to copy IPC message to transport buffer in order to send the message from IOSd to Forwarding Manager. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP-3-MSGENQERR : Unable to enqueue IPC messages to IOS IPC queue. Message: [chars]. | |
---|---|
Explanation | An unexpected condition has occurred while IOS trying to enqueue IPC message to IOS IPC queue in order to send the message to Forwarding Manager. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP-4-MSGNONTDLSTATSERR : Unable to process received non-TDL stats message from Forwarding Manager, error: [chars] ([dec]). |
|
---|---|
Explanation | An unexpected condition has occurred while IOS trying to process received non-TDL stats message from Forwarding Manager. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_FMANRP_ADJ
%IOSXE_FMANRP_ADJ-3-NOADJ : Adjacency entry is null | |
---|---|
Explanation | An unexpected condition has occurred which is due to the absence of an adjacency entry structure. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show adjacency command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_ADJ-3-NOFIBHWIDB : FIB Interface [chars] is null | |
---|---|
Explanation | An unexpected condition has occurred which is due to the absence of a FIB interface structure. |
Recommended Action | LOG_STD_SH_CMD_ACTION(show adj) |
%IOSXE_FMANRP_ADJ-3-ENQUEFAIL : Unable to send [chars] [chars] message to Forwarding Manager Process | |
---|---|
Explanation | An unexpected condition has occurred which resulted in a configuration not being sent to the Forwarding Manager Processs. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_ADJ-3-ENCSIZE : Invalid encap length [dec] which is larger than max allowed [dec] bytes | |
---|---|
Explanation | An unexpected condition has occurred which is due to invalid adjacency encapsulation size being larger than the maximum value allowed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_FMANRP_CCE
%IOSXE_FMANRP_CCE-4-CCE_STACK_LIMIT : Failed to create class [dec] filter list | |
---|---|
Explanation | An operation to send a filter list to the forwarding processor for a particular class has failed due to a resource issue. This may imply that the notification was dropped. |
Recommended Action | LOG_STD_SH_CMD_ACTION(show class-map [type <class type> <name>]) |
%IOSXE_FMANRP_CCE-3-CCE_INVALID_FILTER_RELN : Invalid filter relation [int] | |
---|---|
Explanation | An internal error occured when trying to build class-map information for one of the classes in a policy-map. |
Recommended Action | LOG_STD_SH_CMD_ACTION(show policy-map [type <policy type> <name>]) |
%IOSXE_FMANRP_CCE-3-CCE_FILTER_OVERFLOW : Filter list overflow at type [chars] | |
---|---|
Explanation | An internal error occured when trying to build class-map information for one of the classes in a policy-map. |
Recommended Action | LOG_STD_SH_CMD_ACTION(show class-map [type <class type> <name>]) |
%IOSXE_FMANRP_CCE-3-CCE_CLASS_CREATE : Unable to create class [int].[int] | |
---|---|
Explanation | An error occured when trying to create a class-map. |
Recommended Action | LOG_STD_SH_CMD_ACTION(show policy-map [type <policy type> <name>]) |
%IOSXE_FMANRP_CCE-4-CCE_NESTED_CLASS_LIMIT : Nested class [dec] layers cannot exceed 4 | |
---|---|
Explanation | When configure nested classes as match statements, the total levels of nested classes cannot exceed 4 layers |
Recommended Action | LOG_STD_SH_CMD_ACTION(show class-map [type <class type> <name>]) |
IOSXE_FMANRP_CEF through IOSXE_MEMPOOL_MIB
-
IOSXE_FMANRP_CEF
-
IOSXE_FMANRP_FPM
-
IOSXE_FMANRP_OBJID
-
IOSXE_FMANRP_OBJID2
-
IOSXE_FMANRP_RTMAP
-
IOSXE_FMANRP_URPF
-
IOSXE_FMANRP_ZONES
-
IOSXE_INFRA
-
IOSXE_LICENSE_POLICY_MANAGER
-
IOSXE_MEMPOOL_MIB
IOSXE_FMANRP_CEF
%IOSXE_FMANRP_CEF-3-NOFIB : FIB entry is null | |
---|---|
Explanation | An unexpected condition has occurred which is due to the absence of a FIB entry structure. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show ip cef command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_CEF-3-NOFIBSB : FIB SB entry is null | |
---|---|
Explanation | An unexpected condition has occurred which is due to the absence of a FIB SB entry structure. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show ip cef command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_CEF-3-NOFIBTABLE : FIB table is null | |
---|---|
Explanation | An unexpected condition has occurred which is due to the absence of a FIB table structure. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show ip cef command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_CEF-3-NOFIBIDB : FIB interface is null | |
---|---|
Explanation | An unexpected condition has occurred which is due to the absence of a FIB interface structure. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show ip cef command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_CEF-3-ENQUEFAIL : Unable to send [chars] [chars] message to Forwarding Manager Process | |
---|---|
Explanation | An unexpected condition has occurred which resulted in a configuration not being sent to the Forwarding Manager Processs. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_CEF-4-UPDFRAGSTATSERR : Update IP Fragmentation statistics error | |
---|---|
Explanation | An unexpected condition has occurred when updating fragmentation statistics |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_CEF-4-UPDREASSSTATSERR : Update IP Reassembly statistics error | |
---|---|
Explanation | An unexpected condition has occurred when updating reassembly statistics |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_CEF-4-UPDSTATSERR : Update CEF statistics error | |
---|---|
Explanation | An unexpected condition has occurred when updating cef statistics |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_CEF-3-ROUTEMSGMARSHAL : Failed to copy route essage to IPC buffer for prefix [chars]/[dec] — [chars] | |
---|---|
Explanation | This operation to build a TDL messages for route download has failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_CEF-3-NOFIBPUSHCNT : FIB push counter is null | |
---|---|
Explanation | An unexpected condition has occurred which is due to the absence of a FIB push counter structure. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show ip cef command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_CEF-3-NOFIBSIGNAL : FIB signal is null | |
---|---|
Explanation | An unexpected condition has occurred which is due to the absence of a FIB signal structure. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show ip cef command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_CEF-3-NONATADDR : NAT address is null | |
---|---|
Explanation | An unexpected condition has occurred which is due to the absence of an NAT address. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show ip alias command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_FMANRP_FPM
%IOSXE_FMANRP_FPM-4-INVALIDLENTYPE : Field length type in PHDF file is invalid | |
---|---|
Explanation | An unexpected condition has occurred which is due to the invalid field length type in PHDF file. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_FPM-4-INVALIDMATCHTYPE : FPM match type is invalid [dec] | |
---|---|
Explanation | An unexpected condition has occurred which is due to the invalid FPM match type in one of FPM class-map filter match entry |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_FPM-4-INVALIDACTION : FPM feature action is invalid [dec] | |
---|---|
Explanation | An unexpected condition has occurred which is due to the invalid action type when trying to bind FPM action with target class group. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_FPM-3-NOSTATUPDATE : Failed to update class-map statistics during periodic update | |
---|---|
Explanation | A statistics update for a class-map has failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_FMANRP_OBJID
%IOSXE_FMANRP_OBJID-5-DUPCREATE : Duplicate forwarding object creation obj_handle [hex], type [int], existing obj_id [hex], type [int] |
|
---|---|
Explanation | An unexpected condition has occurred which results in duplicate forwarding object creation. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_FMANRP_OBJID2
%IOSXE_FMANRP_OBJID2-3-DUPCREATE : Duplicate forwarding object creation obj_handle [hex], type [int], existing obj_id [hex], type [int] |
|
---|---|
Explanation | An unexpected condition has occurred which results in duplicate forwarding object creation with different object types. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_FMANRP_RTMAP
%IOSXE_FMANRP_RTMAP-3-RTMAPNULL : The route-map structure for [chars] is null | |
---|---|
Explanation | An unexpected condition has occurred which is due to the absence of a route-map data structure. |
Recommended Action | show route-map |
%IOSXE_FMANRP_RTMAP-4-UNKOWNCLIANT : Unknown client type [dec] received | |
---|---|
Explanation | An unexpected known client type is received for route-map download. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_RTMAP-3-INVALID_LIST : NULL | |
---|---|
Explanation | An internal list structure has been detected as invalid. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_RTMAP-3-RTMAP_UNSUPPORTED : Routemap ([chars]) contain unsupported match/set clause, ignored | |
---|---|
Explanation | A map contains unsupported match or set clause |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_FMANRP_URPF
%IOSXE_FMANRP_URPF-4-NOV4SWIDB : v4 sub-interface is null | |
---|---|
Explanation | An unexpected condition has occurred which is due to the absence of a v4 swidb structure. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show ip interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_URPF-4-NOV6SWIDB : v6 sub-interface is null | |
---|---|
Explanation | An unexpected condition has occurred which is due to the absence of a v6 swidb structure. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show ipv6 interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_URPF-3-INVALIDIFHDL : Invalid interface handle [int] for interface (number= [int], swidb= [hex], name= [chars]) | |
---|---|
Explanation | An unexpected condition has occurred which is due to an invalid interface handle |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_URPF-4-UPDV4STATSERR : Update v4 URPF statistics error | |
---|---|
Explanation | An unexpected condition has occurred when updating v4 URPF statistics |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show ip interface <name> command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_FMANRP_URPF-4-UPDV6STATSERR : Update v6 URPF statistics error | |
---|---|
Explanation | An unexpected condition has occurred when updating v6 URPF statistics |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show ipv6 interface <name> command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_FMANRP_ZONES
%IOSXE_FMANRP_ZONES-3-NOSTATUPDATE : Failed to update zone-pair statistics during periodic update (zone [chars], class [int]) | |
---|---|
Explanation | A statistics update for a zone-pair has failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_INFRA
%IOSXE_INFRA-3-INVALID_ERRMSG : Error message type [dec] not defined | |
---|---|
Explanation | Error message type used is not defined in IOSXE infrastruction |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-SHIM_INIT_WQ_FAIL : IOSXE shim layer initialization failed: Can not create receiving queues | |
---|---|
Explanation | IOSXE IOS shim layer initialization of watched queue failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-SHIM_INIT_WQ_CHASFS_FAIL : IOSXE shim layer initialization failed: Can not create receiving chasfs watched queue |
|
---|---|
Explanation | IOSXE IOS shim layer initialization of watched queue failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-SHIM_INIT_PROC_FAIL : IOSXE shim layer initialization failed: Dispatch process creation failed | |
---|---|
Explanation | IOSXE IOS shim layer initialization creating dispatch process failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-SHIM_INIT_MEM_FAIL : IOSXE shim layer initialization failed: Memory initialization failed. | |
---|---|
Explanation | IOSXE IOS shim layer initialization of memory failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-SHIM_NO_IPC_DISPATCH_HDL : IOSXE shim layer [chars] process message without IPC dispatch handler. | |
---|---|
Explanation | IOSXE IOS shim layer has no ipc dispatch handler set |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-SHIM_RXMSG_NO_IPC_HDL : IOSXE shim layer without IPC handler for fd [dec], seqnum [dec]. | |
---|---|
Explanation | IOSXE IOS shim layer cannot find ipc handler |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-SHIM_INIT_TDL_FAIL : IOSXE shim layer initialization TDL Lib [chars] failed. | |
---|---|
Explanation | IOSXE IOS shim layer initialization of TDL library |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-SHIM_INIT_DISPATCH_INIT_FAIL : IOSXE shim layer initialization, dispatch path init failed. | |
---|---|
Explanation | IOSXE IOS shim layer initialization of TDL disatch path |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-INVALID_RUNTIME_IDX : Thread runtime index [dec] is not valid | |
---|---|
Explanation | Export the thread’s running time failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-6-THEAD_SELECT_ERR : Inbound message or packet select error, [chars]. | |
---|---|
Explanation | Socket select operation error in threads |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-INJECT_HDR_LENGTH_ERR : Inject hdr size [int] exceeds limit | |
---|---|
Explanation | Inject header length exceeds pak header space |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-INJECT_EMBEDDED_HDR_LENGTH_ERR : Can’t allot space needed for embedded inject hdr size [int] exceeds limit | |
---|---|
Explanation | Can’t allot space needed for embedded inject header, exceeds pak header space |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-INJECT_NO_IF_OUTPUT_ERR : Output intf is NULL, [chars] | |
---|---|
Explanation | Output intf is requred to proceed, else skip the feautre |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-4-PUNT_KEEPALIVE_LOG_ERR_INV_PARAM : Invalid parameter: [chars] | |
---|---|
Explanation | Invalid parameter was passed when generating punt err log |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-4-PUNT_KEEPALIVE_LOG_ERR_GET_FILE_NAME : Failed to get file name: [chars] | |
---|---|
Explanation | Could not form a file name when generating punt err logPunt keepalive log error seen |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-4-PUNT_KEEPALIVE_LOG_ERR_INV_FILE_ID : Invalid file descriptor: [dec] | |
---|---|
Explanation | Invalid file descriptor was found when generating punt err log |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-PUNT_KEEPALIVE_LOG_ERR_OPEN_FILE : Failed to open file: [chars] | |
---|---|
Explanation | Failed to open file when generating punt err log |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-4-PUNT_KEEPALIVE_LOG_ERR_CLOSE_FILE : Failed to close file with descriptor: [dec] | |
---|---|
Explanation | Closing of file failed when generating punt err log |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-PUNT_KEEPALIVE_LOG_ERR_WRITE_TO_FILE : Write to file Id [dec] failed [dec] bytes, expected [dec] bytes | |
---|---|
Explanation | Write to file failed when generating punt err log |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-PUNT_KEEPALIVE_LOG_ERR_ALLOC_TTY : Failed to allocate a tty | |
---|---|
Explanation | Can’t allocate a TTY when generating punt err log |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-PUNT_KEEPALIVE_LOG_ERR_ALLOC_CSB : Failed to allocate a csb | |
---|---|
Explanation | Can’t allocate a csb when generating punt err log |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-PUNT_KEEPALIVE_LOG_ERR_PARSE_CMD : Failed to parse command: [chars] | |
---|---|
Explanation | Failed to parse a command when generating punt err log |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-4-PUNT_KEEPALIVE_LOG_ERR_GET_PROCID : Failed to get process id | |
---|---|
Explanation | Can’t get identifier of the process generating punt err log |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-4-PUNT_KEEPALIVE_LOG_ERR_INV_PROCID : Invalid proc id [dec], expected [dec] | |
---|---|
Explanation | Invalid process trying to generate punt err log |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-4-NO_PUNT_KEEPALIVE : Keepalive not received for [int] seconds | |
---|---|
Explanation | Punt Inject keepalive message was not received |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-2-FATAL_NO_PUNT_KEEPALIVE : Keepalive not received for [int] seconds resetting | |
---|---|
Explanation | Punt Inject keepalive message was not received |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-2-FATAL_PUNT_LINK_DOWN : Punt Inject link went down resetting | |
---|---|
Explanation | Punt Inject link went down |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-INJECT_GSB_CTL_INIT_FAIL : Inject adjacency subblock init failed | |
---|---|
Explanation | Adj subblock control or register failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-PUNT_ADDR_RES_ENCAP_ERR : Punted address resolution packet with unknown encap [chars] | |
---|---|
Explanation | Punted packet for ARP/ND with encap not supported |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-PUNT_SVC_PROC_ERR : Punt service [chars] create failed | |
---|---|
Explanation | Punt service process can not be created |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-VM_PAGE_TABLE_ERR : VM guarded page operation failed, address [hex], [chars] | |
---|---|
Explanation | VM guarded page avl tree operation error |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-PUNT_SVC_TYPE_UNKNOWN : Punted packet with unknown service type [int] | |
---|---|
Explanation | Punted pak with an unsupported service type |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-5-PUNT_SVC_CANT_ENQUEUE : Punted pak can’t be enqueued for service | |
---|---|
Explanation | Punted pak enqueue failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-5-PUNT_SVC_INVALID_OPT_PKT : Invalid IPv4 options packet punted to RP | |
---|---|
Explanation | Invalid IPv4 options packet dropped in RP |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-4-INJECT_TUN_NONIP_WARN : pak with linktype [chars] gets into non-ip tunnel | |
---|---|
Explanation | IP/IPv6/MPLS packet should to go through GRE tunnel for non-IP payload |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-INJECT_FEATURE_ESS_ERR : ESS segment not found, type [dec] hdl [hex] | |
---|---|
Explanation | Packets to be injected to an unsupported ESS segment |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-6-PROCPATH_CLIENT_HOG : IOS shim client ‘[chars]’ has taken %ld msec (runtime: %ld msec) to process a ‘[chars]’ message |
|
---|---|
Explanation | The specified IOSXE IOS shim client has taken too long to process a received IPC or chasfs message |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-6-AUXTHD_REQUEST : Too many outstanding requests for file system access | |
---|---|
Explanation | Resource temporarily unavailable |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-APP_SESS_OPEN_FAILED : An attempt to open [chars] with handle number [dec] has failed ([dec]) | |
---|---|
Explanation | Application session between processes failed to estabish. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-CONSOLE_DBUG_DROP : System dropped [dec] bytes of console debug messages. | |
---|---|
Explanation | Debugging messages are being generated faster than they can be displayed on the console. The messages can not be guaranteed to be seen so this message replaces the lost messages. |
Recommended Action | Consider using conditional debugging or turning off console logging. |
%IOSXE_INFRA-3-PUNT_INCOMP_WRONG_ADJID : Punted address resolution packet linktype [chars], adj-id [dec] is with linktype [chars] |
|
---|---|
Explanation | CPP needs to punt incomplete adjacency for resolution by specifying the adjacency-id, but the included adjacency-id does not match the incomplete adjacency this packet triggered. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-IFS_EXTLINK_ADD_FAIL : Could not add filesystem [chars] to IFS links | |
---|---|
Explanation | Attempt to add filesystem root to allow for links failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-IFS_UDEV_REMOVE_FAIL : Could not remove udev device [chars] | |
---|---|
Explanation | Attempt to remove udev device failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-IFS_DFLT_FS_REG_FAIL : Unable to set [chars] as a default file system. | |
---|---|
Explanation | IOSXE’s platform dependent code failed to register the default file system. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-IFS_INIT_HIDDEN_FAIL : IOSXE shim layer initialization failed: Can not create receiving queues | |
---|---|
Explanation | IOSXE IOS shim layer initialization of hidden path watch failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-BSO_MSG_HDR_LENGTH_ERR : BSO message header length [int] is incorrect | |
---|---|
Explanation | BSO message header length is incorrect |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-BSO_MSG_HDR_MSGTYPE_ERR : BSO message header msgtype [int] is incorrect | |
---|---|
Explanation | BSO message header msgtype is incorrect |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-BSO_MSG_UNMARSHAL_ERR : BSO message unmarshalling has failed | |
---|---|
Explanation | BSO message unmarshalling has failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-BSO_MSG_CACHE_ERR : BSO message query cache update error — [chars] | |
---|---|
Explanation | BSO message query cache update error |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-4-BSO_MSG_RIB_WATCH_WARN : BSO message RIB watch start error | |
---|---|
Explanation | BSO message RIB watch start error |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-RELOAD_INFO_SAVE_FAIL : Unable to save reload information: [dec]: [chars]. | |
---|---|
Explanation | IOSXE’s platform dependent code failed to save the reload information. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-SN_IPFRR_PROC_ERR : Static Nexthop IPFRR [chars] create failed | |
---|---|
Explanation | SN IPFRR process can not be created |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-6-CONSOLE_ACTIVE : [chars] | |
---|---|
Explanation | Indicates that the current instance of IOS is assuming active control of the console. This is informational. |
Recommended Action | No action is required. |
%IOSXE_INFRA-6-PLATFORM_RELOAD : [chars] | |
---|---|
Explanation | Indicates that the current instance of IOS is being reset by the platform code. This is part of a normal reset sequence and the message is informational. |
Recommended Action | No action is required. |
%IOSXE_INFRA-6-CHASFS_CLOCK_SET_FAIL : Failed to set Chasfs property on system time change | |
---|---|
Explanation | Unable to set chasfs property on system time change |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-CYAN_API_ERROR : Failed to retrieve platform dependent value of [chars] (err=[dec]) | |
---|---|
Explanation | CYAN API function failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-6-SHIM_RXMSG_IPC_INFO : IOS shim layer process IPC msg for fd [dec], seq_num [dec], ipc_status [dec] | |
---|---|
Explanation | |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-SHIM_IPC_NOT_PROCESSED : msg handler returned FALSE for IPC msg for fd [dec], seq_num [dec], service [chars] | |
---|---|
Explanation | |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-SWIFT_ORCH_PROC_FAIL : IOSXE SWIFT Orchestrator process creation failed | |
---|---|
Explanation | The SWIFT Orchestrator process could not be created |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-BAD_GLIBC_BUF_FREE : An IOS buffer is freed into GLIBC buffer pool, buffer blockmagic [hex], flags [hex] | |
---|---|
Explanation | An IOS buffer is freed into GLIBC buffer pool. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-BIPC_MGS_ALLOC_FAIL : Allocating [dec] byte for IPC [chars] msg failed: out of memory | |
---|---|
Explanation | system is out of memory |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-SOCKET_PEEK_ERR : Interrupt processing of Punt received packets over socket failed as peek of packet returned error: [chars] |
|
---|---|
Explanation | Peek at incoming message hit error |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-GET_BUFFER_ERR : Interrupt processing of Punt received packets over socket failed to get a packet buffer for len [dec] |
|
---|---|
Explanation | Failed to get a packet buffer from the specified pool. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-SOCKET_RECV_ERR : Interrupt processing of Punt received packets over socket failed as receive packet hit error: [chars] |
|
---|---|
Explanation | Hit error when receives packet from a socket. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-SOCKET_SEND_ERR : Transmit packet to the socket hit error: [chars] | |
---|---|
Explanation | Transmit a packet to another socket hit error. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-INJECT_HEADER_ERR : Transmit packet to the socket failed as packet header length is greater than datagram size. It’s an incorrect packet and cannot proceed sending. header length is [dec], datagram size is [dec]. |
|
---|---|
Explanation | Packet header length is wrong. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-IDB_CREATE_ERR : Failed to create IDB(Interface Descriptor Block) for Punt/Inject socket interface | |
---|---|
Explanation | Creating an idb corresponding to an interface failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-MALLOC_FAST_ERR : Failed to allocate memory for Punt/Inject socket instance | |
---|---|
Explanation | malloc_fast failed to allocate memory. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-IDB_INIT_ERR : Failed to initialize IDB(Interface Descriptor Block) for Punt/Inject socket interface | |
---|---|
Explanation | Hit error when we initialize idb. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-PI_SOCKET_RAW_PRE_INIT_ERR : Punt/Inject socket pre-initialization(IDB creation) failed | |
---|---|
Explanation | PI Socket Raw pre-initialization failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-PI_SOCKET_RAW_INIT_ERR : Punt/Inject socket initialization failed | |
---|---|
Explanation | PI Socket Raw initialization failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-MCPRP_INIT_PUNTPATH_FD_ERR : Initializing the ipc control for the puntpath fd failed | |
---|---|
Explanation | Initializing the ipc control for the puntpath fd failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_INFRA-3-LIIN_TUN_MSG_ERR : LIIN error — [chars] [chars] [dec] | |
---|---|
Explanation | LIIN in Tunnel mode experiencing error |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_LICENSE_POLICY_MANAGER
%IOSXE_LICENSE_POLICY_MANAGER-2-CONFIG_NULL : [chars]: Configuration is unavailable | |
---|---|
Explanation | License Configuration is undefined for this platform. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_LICENSE_POLICY_MANAGER-2-FEATURE_CONFIG_NULL : [chars]: Feature Configuration is unavailable | |
---|---|
Explanation | Feature Configuration is undefined for this platform. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_LICENSE_POLICY_MANAGER-2-FEATURE_MALLOC_FAILED : [chars]: Policy Mgr Feature Registration struct malloc failed | |
---|---|
Explanation | Memory allocation for Feature Registration Struct failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_LICENSE_POLICY_MANAGER-2-FEATURE_NAME_NULL : [chars]: Feature name is NULL | |
---|---|
Explanation | License feature name string is NULL |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_LICENSE_POLICY_MANAGER-2-LIC_REG_FAILED : [chars]: Failed to register [chars] license feature, result = [hex] | |
---|---|
Explanation | License Registration failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_LICENSE_POLICY_MANAGER-2-LIC_REQ_FAILED : [chars]: [dec]/[dec]: Lic request failed (idx:[dec]), feature=[chars], lic_cnt=[dec], err=[dec] |
|
---|---|
Explanation | License Request failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_LICENSE_POLICY_MANAGER-2-LIC_REL_FAILED : [chars]: [dec]/[dec]: Lic release failed (idx:[dec]), feature=[chars], lic_cnt=[dec], err=[dec] |
|
---|---|
Explanation | License Release failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_LICENSE_POLICY_MANAGER-2-LIC_REQ_GEN_FAIL : [chars]: [dec]/[dec]: Lic request failed | |
---|---|
Explanation | License Request failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_LICENSE_POLICY_MANAGER-2-LIC_REL_GEN_FAIL : [chars]: [dec]/[dec]: Lic request failed | |
---|---|
Explanation | License Release failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_LICENSE_POLICY_MANAGER-2-BAY_MALLOC_FAILED : [chars]: Policy Mgr Bay DB malloc failed for [dec]/[dec] | |
---|---|
Explanation | Memory allocation for SPA/EPA failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_LICENSE_POLICY_MANAGER-2-IF_MALLOC_FAILED : [chars]: Policy Mgr IF DB malloc failed for [dec]/[dec] | |
---|---|
Explanation | Memory allocation for SPA/EPA interfaces failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_LICENSE_POLICY_MANAGER-6-LIC_REQ_SUC : [int]/[int]/[int]: License request is successful for [chars] feature | |
---|---|
Explanation | License release is successful, port allowed to go down |
Recommended Action | Nothing the system is working properly |
%IOSXE_LICENSE_POLICY_MANAGER-6-LIC_REL_SUC : [int]/[int]/[int]: License release is successful for [chars] feature | |
---|---|
Explanation | License release is successful, port allowed to go down |
Recommended Action | Nothing the system is working properly |
%IOSXE_LICENSE_POLICY_MANAGER-4-INSUF_LIC : [int]/[int]/[int]: Insufficient [chars] license, skipping license request assuming customer has honor license |
|
---|---|
Explanation | Permanent/Evaluation licenses have exhausted, skipping license request asuming customer has purchased license |
Recommended Action | Nothing the system is working properly |
%IOSXE_LICENSE_POLICY_MANAGER-4-DISABLE_MACSEC : [chars]: Disabling MACsec configuration due to insufficient license | |
---|---|
Explanation | Disabling MACsec configuration from port due to insufficient MACsec license |
Recommended Action | Purchase/Install MACsec license |
IOSXE_MEMPOOL_MIB
%IOSXE_MEMPOOL_MIB-3-BUFFPOOL_REG_ERROR : Bufferpool register data exceeds allocated memory; Retrieved only [dec] entries. | |
---|---|
Explanation | Memory allocated is not enough |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_MGMTVRF through IOSXE_RP_IF_FLOW_IDS
-
IOSXE_MGMTVRF
-
IOSXE_MLP
-
IOSXE_OIR
-
IOSXE_PEM
-
IOSXE_PLATFORM
-
IOSXE_QFP
-
IOSXE_RP_ALARM
-
IOSXE_RP_CFG_NOT
-
IOSXE_RP_DPIDB
-
IOSXE_RP_IF_FLOW_IDS
IOSXE_MGMTVRF
%IOSXE_MGMTVRF-3-PROCESS_CREATE_FAIL : Management VRF process creation failed, [chars] | |
---|---|
Explanation | Can not create IOS process for mgmt port init |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_MGMTVRF-3-VRF_CREATE_FAIL : Management VRF creation failed [chars] | |
---|---|
Explanation | Can not create mgmt vrf during system init |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_MGMTVRF-3-AFI_ATTACH_FAIL : Management VRF AFI [chars] attach failed | |
---|---|
Explanation | Can not create afi subblock for mgmt vrf |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_MGMTVRF-3-INTF_ATTACH_FAIL : Management VRF attach to mgmt [chars] failed | |
---|---|
Explanation | Can not associate mgmt port to mgmt vrf |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_MGMTVRF-3-SET_TABLEID_FAIL : Installing [chars] Management interface tableid [hex] failed | |
---|---|
Explanation | Fail to set mgmt port tableid into Linux kernel |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_MGMTVRF-6-CREATE_SUCCESS_INFO : Management vrf [chars] created with ID [dec], ipv4 table-id [hex], ipv6 table-id [hex] | |
---|---|
Explanation | mgmt vrf and ipv4, ipv6 tables created for mgmt port |
Recommended Action |
IOSXE_MLP
%IOSXE_MLP-3-ENQUEFAIL : Unable to send [chars] [chars] message to Forwarding Manager Process | |
---|---|
Explanation | An unexpected condition has occurred which resulted in a configuration not being sent to the Forwarding Manager Processs. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_MLP-4-UPDSTATSERR : Update MLP statistics error | |
---|---|
Explanation | An unexpected condition has occurred when updating mlp statistics |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_MLP-2-DB_ENTRY_ALLOC_FAIL : MLP link db entry allocation for link [chars] failed | |
---|---|
Explanation | MLP link database error. Memory chunk allocation for MLP link database entry has failed. |
Recommended Action | Check for accurate memory management. Perform memory leak checks and look for memory corruption causes. Execute ‘show proc memory’ command. |
%IOSXE_MLP-2-DB_INSERT_FAIL : MLP link db entry add for interface [chars] failed | |
---|---|
Explanation | MLP link database error. Insertion of a new entry into MLP link database has failed. |
Recommended Action | Check for accurate memory management. Perform memory leak checks, look for memory corruption causes, verify correct database management. Execute ‘show proc memory’ command. |
%IOSXE_MLP-2-DB_DELETE_FAIL : MLP link db entry delete for link [chars] failed | |
---|---|
Explanation | MLP link database error. Removal of entry from MLP link database has failed. |
Recommended Action | Check for accurate memory management. Perform memory leak checks, look for mamory corruption causes and check for correct database management. Execute ‘show proc memory’ command. |
%IOSXE_MLP-2-DB_ENTRY_FREE_FAIL : MLP link entry free failed | |
---|---|
Explanation | MLP link database error. Memory chunk free of MLP link database entry has failed. |
Recommended Action | Check for accurate memory management. Perform memory leak checks and look for memory corruption causes. Execute ‘show proc memory’ command. |
%IOSXE_MLP-2-DB_ALLOC_FAIL : MLP link db allocation failed | |
---|---|
Explanation | MLP link database error. Memory chunk creation for MLP link database has failed. |
Recommended Action | Check for accurate memory management. Perform memory leak checks and look for memory corruption causes. Execute ‘show proc memory’ command. |
%IOSXE_MLP-2-DB_DESTROY_FAIL : MLP link database destroy failed | |
---|---|
Explanation | MLP link database error. Memory chunk destroy has failed for MLP link database. |
Recommended Action | Check for accurate memory management. Perform memory leak checks and look for memory corruption causes. Execute show proc memory command. |
IOSXE_OIR
%IOSXE_OIR-6-INSCARD : Card ([chars]) inserted in [chars]slot [chars] | |
---|---|
Explanation | The OIR facility detected the insertion of a card in the slot number specified in the message. |
Recommended Action | No action is required. |
%IOSXE_OIR-6-REMCARD : Card ([chars]) removed from [chars]slot [chars] | |
---|---|
Explanation | The OIR facility detected the removal of a card from the slot number specified in the message. |
Recommended Action | No action is required. |
%IOSXE_OIR-6-ONLINECARD : Card ([chars]) online in [chars]slot [chars] | |
---|---|
Explanation | The OIR facility detected the state change to online for the card in the slot number specified in the message. |
Recommended Action | No action is required. |
%IOSXE_OIR-6-OFFLINECARD : Card ([chars]) offline in [chars]slot [chars] | |
---|---|
Explanation | The OIR facility detected the state change to offline for the card in the slot number specified in the message. |
Recommended Action | No action is required. |
%IOSXE_OIR-3-CARDERR : Could not read state property for [chars] slot [dec] | |
---|---|
Explanation | The OIR facility detected a failure for exceeding the number of retries to find state chasfs property. |
Recommended Action | No action is required. |
%IOSXE_OIR-6-SOFT_STARTSPA : SPA([chars]) restarted in [chars] | |
---|---|
Explanation | The SPA in the specified subslot is restarted by the command hw-module subslot slot#/subslot# start |
Recommended Action | No action is required. |
%IOSXE_OIR-3-SPA_INTF_ID_ALLOC_FAILED : Failed to allocate interface identifiers for SPA([chars]) in slot/bay: [int]/[int] | |
---|---|
Explanation | Failed to get CC buffer and flow control identifiers for the SPA in the specified subslot Traffic cannot flow through the SPA under this failure condition. This can happen if the system runs out of available identifiers. |
Recommended Action | Try to reduce the number of interfaces configured in the system either by physically removing the SPAs or by changing the system configuration |
%IOSXE_OIR-6-SOFT_STOPSPA : SPA([chars]) stopped in [chars], interfaces disabled | |
---|---|
Explanation | The SPA in the specified subslot is stopped by the command hw-module subslot slot#/subslot# stop The interfaces on that processor will be administratively shut down and marked as removed. The routing table will be flushed of any routes through the removed interfaces. |
Recommended Action | No action is required. |
%IOSXE_OIR-6-SOFT_RELOADSPA : SPA([chars]) reloaded on [chars] | |
---|---|
Explanation | The SPA in the specified subslot is reloaded by the command hw-module subslot slot#/subslot# reload |
Recommended Action | No action is required. |
%IOSXE_OIR-6-SYNCSPA : SPA ([chars]) reloading to come up in [chars] mode | |
---|---|
Explanation | The SPA in the specified subslot is reloaded by the command hw-module subslot slot#/subslot# reload |
Recommended Action | No action is required. |
%IOSXE_OIR-6-INSSPA : SPA inserted in [chars]/[int] | |
---|---|
Explanation | The OIR facility detected the insertion of a SPA in the subslot number specified in the message. |
Recommended Action | No action is required. |
%IOSXE_OIR-6-REMSPA : SPA removed from [chars]/[int], interfaces disabled | |
---|---|
Explanation | The OIR facility detected the removal of a SPA from the subslot number specified in the message. The interfaces on that processor will be administratively shut down and marked as removed. The routing table will be flushed of any routes through the removed interfaces. |
Recommended Action | No action is required. |
%IOSXE_OIR-6-INSSSFP : Smart SFP inserted in port [chars] | |
---|---|
Explanation | The OIR facility detected the insertion of TSoP/VCoP SSFP in the port number specified in the message. |
Recommended Action | No action is required. |
%IOSXE_OIR-6-REMSSFP : Smart SFP removed from port [chars] | |
---|---|
Explanation | The OIR facility detected the removal of TSoP/VCoP SSFP in the port number specified in the message. |
Recommended Action | No action is required. |
%IOSXE_OIR-6-SPARELOAD : SPA reloaded on subslot [int]/[int] | |
---|---|
Explanation | The SPA in the specified subslot is reloaded. |
Recommended Action | No action is required. |
%IOSXE_OIR-6-CARDRECONCILE : SPA type changed on subslot [int]/[int] from [int] to [int] | |
---|---|
Explanation | The SPA in the specified subslot has been initialized, and it has been detected that it is of a different type to the SPA that was previously in this subslot. |
Recommended Action | No action is required. |
%IOSXE_OIR-3-OIRTWICE : Subslot [int]/[int] OIR insertion/removal not paired up: [chars] | |
---|---|
Explanation | An internal OIR-related error occured for the specified SPA. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_OIR-3-QUIESCE_FAIL : Quiesce failed for subslot [int]/[int] (error = [dec]) | |
---|---|
Explanation | The RP failed to contact the SPA during failover. The SPA will be reset. |
Recommended Action | No action is required. |
%IOSXE_OIR-3-UNQUIESCE_FAIL : Unquiesce failed for subslot [int]/[int] (error = [dec]) | |
---|---|
Explanation | The RP failed to unquiesce the SPA in the specified subslot. The SPA will be reset. |
Recommended Action | No action is required. |
%IOSXE_OIR-3-POWER_CYCLE_IMMINENT : The SPA in subslot [int]/[int] will be power cycled in [dec] seconds. | |
---|---|
Explanation | The SPA in the specified subslot will be power cycled in the amount of time specified in the error message. |
Recommended Action | No action is required. |
%IOSXE_OIR-3-PROCMSG : Process msg send failed for process[dec] | |
---|---|
Explanation | Process message send failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_OIR-3-MODULE : Missing [chars] for [chars] | |
---|---|
Explanation | A hardware or software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_OIR-3-SPA_MDR_FAIL : Minimal Disruptive Restart process failed for SPA in subslot [int]/[int], reason [chars]. | |
---|---|
Explanation | The SPA in the subslot failed Minimal Disruptive Restart. Minimal Disruptive Restart process is aborted and an attempt will be made to recover the SPA by resetting the SPA hardware. |
Recommended Action | No action is required. |
IOSXE_PEM
%IOSXE_PEM-6-INSPEM_FM : PEM/FM [chars] inserted | |
---|---|
Explanation | The platform detected the insertion of a power/fan module in the slot number specified in the message. |
Recommended Action | No action is required. |
%IOSXE_PEM-6-REMPEM_FM : PEM/FM [chars] removed | |
---|---|
Explanation | The platform detected the removal of a power/fan module in the slot number specified in the message. |
Recommended Action | No action is required. |
%IOSXE_PEM-6-PEMOK : The PEM in [chars] is functioning properly | |
---|---|
Explanation | The PEM hardware may have been either switched off, or reporting a failure condition. This message indicates that the PEM is no longer either switched off, or reporting a failure |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_PEM-3-PEMFAIL : The PEM in [chars] is switched off or encountering a failure condition. | |
---|---|
Explanation | The PEM hardware has been either switched off, or is reporting a failure condition. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_PEM-6-FANOK : The fan in [chars]/[dec] is functioning properly | |
---|---|
Explanation | The fan was reporting a failure condition. This message indicates that the fan is no longer reporting a failure |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_PEM-3-FANFAIL : The fan in [chars]/[dec] is encountering a failure condition | |
---|---|
Explanation | The fan’s hardware is reporting that the fan is failing. This is most likely because the hardware detects the fan as spinning below the minimum speed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_PEM-3-PEMCHASFSERR : The PEM in [chars] has encountered a system software error. | |
---|---|
Explanation | The PEM’s underlying software for storing PEM state is not working properly. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_PEM-3-TEMPERATURE_RAISE : Sensor [chars] has reached maximum temeprature value, Leads to shutdown the system | |
---|---|
Explanation | The Temperature sensor reaching maximum threshold value working properly. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_PEM-3-FAN_FAIL_SHUTDOWN : More thatn one [chars] has failed, Leads to shutdown the system | |
---|---|
Explanation | The Temperature sensor reaching maximum threshold value working properly. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_PEM-3-SSFP_TEMPERATURE_RAISE : [chars] transceiver temeprature reached threshold value, Leads to shutdown the system | |
---|---|
Explanation | The Temperature sensor reaching maximum threshold value working properly. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_PEM-3-PEMREDLOWSTANDBY : Cannot activate [chars] configuration. Total power budget of standby power supplies is [dec]W. Standby power must be greater than or equal to the largest power supply capacity ([dec]W). |
|
---|---|
Explanation | Operating in unprotected mode Should insert at least one ps in standby slots with a capacity greater than or equal to the largest capacity power supply in the system. The configuration will be applied automatically once requirements are met. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_PEM-3-PEMREDNOPWR : Cannot enable power redundancy mode [chars] because config would create mode with insufficient [chars] power |
|
---|---|
Explanation | Configuration set by user is not valid as power supplies in the active slots do not contain enough power to meet the power requirements |
Recommended Action | Insert additional power supplies and configure them to be active or configure current standby power supplies to active such that power requirements are met |
IOSXE_PLATFORM
%IOSXE_PLATFORM-3-WDC_INVALID_LENGTH : WDC length can not be determined: [dec] | |
---|---|
Explanation | WDC length was not retrieved properly |
Recommended Action | Check if WDC is programmed on this device |
%IOSXE_PLATFORM-3-WDC_NOT_FOUND : WDC returned length: [dec] | |
---|---|
Explanation | WDC length was set to 0, which specifies probably WDC does not exist |
Recommended Action | Check if WDC is programmed on this device |
%IOSXE_PLATFORM-3-WDC_TLV_NOT_FOUND : WDC TLV could not be read from the Quack device | |
---|---|
Explanation | WDC TLV couldn’t be read from the Quack device |
Recommended Action | Check if WDC is programmed on this device |
IOSXE_QFP
%IOSXE_QFP-2-LOAD_EXCEED : Slot: [int], QFP:[int], Load [int]%[hex]ceeds the setting threshold. | |
---|---|
Explanation | QFP Load exceeds setting threshold. |
Recommended Action | Monitor the traffic load. |
%IOSXE_QFP-2-LOAD_RECOVER : Slot: [int], QFP:[int], Load [int]%% recovered. | |
---|---|
Explanation | QFP Load recovered. |
Recommended Action | No action required (normal operation). |
IOSXE_RP_ALARM
%IOSXE_RP_ALARM-6-INFO : [chars] [chars] [chars]: [chars] [chars] | |
---|---|
Explanation | |
Recommended Action |
%IOSXE_RP_ALARM-6-INFO : [chars] [chars] [chars] [chars] [chars] | |
---|---|
Explanation | Alarm assertion or deassertion information. |
Recommended Action | No action is required. |
%IOSXE_RP_ALARM-2-PEM : [chars] [chars] [chars]: [chars] [chars] | |
---|---|
Explanation | |
Recommended Action |
%IOSXE_RP_ALARM-2-PEM : [chars] [chars] [chars] [chars] [chars] | |
---|---|
Explanation | Power Entity Module missing information |
Recommended Action | No action is required. |
%IOSXE_RP_ALARM-2-ESP : [chars] [chars] [chars]: [chars] [chars] | |
---|---|
Explanation | |
Recommended Action |
%IOSXE_RP_ALARM-2-ESP : [chars] [chars] [chars] [chars] [chars] | |
---|---|
Explanation | No ESP running alarm information |
Recommended Action | No action is required. |
IOSXE_RP_CFG_NOT
%IOSXE_RP_CFG_NOT-3-MSGNOCAND : Can not construct a candidate entry for configuration export | |
---|---|
Explanation | This error usually indicates either an out of memory condition or a TDL error. If ample memory is available, then the the TDL error may indicate a version conflict with respect to configuration. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-3-MSGNOPWARR : Can not construct an array for configuration export | |
---|---|
Explanation | This error usually indicates either an out of memory condition or a TDL error. If ample memory is available, then the the TDL error may indicate a version conflict with respect to configuration. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-3-MSGNOUPDATEMSG : Can not construct an update message for configuration export | |
---|---|
Explanation | This error usually indicates either an out of memory condition or a TDL error. If ample memory is available, then the the TDL error may indicate a version conflict with respect to configuration. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-3-MSGNOREPLMSG : Can not construct a replace message for configuration export | |
---|---|
Explanation | This error usually indicates either an out of memory condition or a TDL error. If ample memory is available, then the the TDL error may indicate a version conflict with respect to configuration. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-2-MSGNOEXP : Can not construct a ‘[chars]’ message for configuration export: [chars] | |
---|---|
Explanation | This error usually indicates either an out of memory condition or a TDL error. If ample memory is available, then the the TDL error may indicate a version conflict with respect to configuration. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-2-MSGTDLINITERROR : Configuration Notification messaging module initialization failed: Unable to initialize messaging: [chars] |
|
---|---|
Explanation | The Configuration Notification subsystem has failed to initialize the infrastructure for messaging with the Pluggable Services Daemon. Notification of configuration to critical modules cannot proceed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-2-MSGTDLERROR : Error processing TDL message. [dec] | |
---|---|
Explanation | An unexpected condition in which IOS has received a TDL message which it can not process. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-2-MSGIPCINITERROR : Error initializing IPC queue | |
---|---|
Explanation | An unexpected condition in which IOS could not initialize a message queue to the PSD. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-3-MSGIPCTXERROR : IPC transmit error. [dec] | |
---|---|
Explanation | An unexpected condition in which IOS encountered an error trying to send a message to another process. %d |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-3-MSGOBJNULL : An unexpected condition in which IOS has received a null pointer that it expects to be non-null. | |
---|---|
Explanation | An unexpected condition has occurred while IOS is trying to process a username command. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-3-MSGENCRYPTINVALID : The mcprp_cfg_notify subsystem has seen an encryption type it does not recognize. [dec] |
|
---|---|
Explanation | An unexpected condition has occurred while IOS is trying to process a username command. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-3-NVWRITE_EXPORT : Failed to export [chars] notification: [dec] | |
---|---|
Explanation | When a ‘write memory’ or ‘write erase’ operation occurs, the Configuration Notification subsystem exports this event into the chassis file system. This message indicates that the export failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-3-MCP_DBPERSIST_STAT : Failed to read [chars] property: [dec] | |
---|---|
Explanation | When a ‘reload’ operation occurs, this chasfs property is read to determine the status of the DB persist/restore/delete operation. This message indicates that the read failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-3-MCP_DBPERSIST_ERROR : System configuration update could not complete | |
---|---|
Explanation | When a ‘reload’ operation occurs, this chasfs property is read to determine the status of the DB persist/restore/delete operation. This message indicates that the operation failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-3-MCP_FRU_LOCATION : Failed to get local FRU location: [dec] | |
---|---|
Explanation | Unable to get local FRU location |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-3-MCP_FRU_INVALID : Unknow FRU location: [chars] | |
---|---|
Explanation | Unknown FRU location |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-3-BOOT_VAR_NOT_SET : Boot variable either does not exist or buffer is too small. Keeping it blank. | |
---|---|
Explanation | Boot variable either does not exist or buffer is too small. Not able to set boot variable. Ignoring it.Aborting reload. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-3-BOOT_IMAGE_NOT_FOUND : Primary image is not found, the system is going to reload as per user request. | |
---|---|
Explanation | Primary image which is set in boot statement either does not exist or not found. Primary image is not found, it should prompt the user to see if they wish to proceed. Aborting reload. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_CFG_NOT-6-IOX_SERVICE_NOTSUPPORTED : IOx service not supported. | |
---|---|
Explanation | IOx service is not supported in this platform currently. This may be either due to the feature unavailability or due the current inadequate license level of the system. |
Recommended Action |
IOSXE_RP_DPIDB
%IOSXE_RP_DPIDB-3-IDXBADRANGE : Datapath IDB index [dec] is not in a valid range | |
---|---|
Explanation | An unexpected condition has occurred as the index of a datapath IDB is not valid. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-IDXALLOCFAILED : Datapath IDB index allocation failed: [chars] | |
---|---|
Explanation | An unexpected condition has occurred as all the available of datapath IDB indices are used. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-IDXINSERTFAILED : Insertion of datapath IDB index [dec] into database failed | |
---|---|
Explanation | An unexpected condition has occurred that insertion of datapath IDB indices failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-IDXLOOKUPFAILED : Lookup of datapath IDB index from the database failed ([chars]) | |
---|---|
Explanation | An unexpected condition has occurred that lookup of datapath IDB indices failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-IDXDELETIONFAILED : Deletion of datapath IDB index from the database failed ([chars] — [hex]) rc [dec] | |
---|---|
Explanation | An unexpected condition has occurred that deletion of datapath IDB indices failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-NOHWSUBBLOCK : HWIDB [chars] does not have a hardware subblock | |
---|---|
Explanation | An unexpected condition has occurred that no hardware subblock was previously allocated for a HWIDB. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-NOSWSUBBLOCK : SWIDB [chars] does not have a software subblock | |
---|---|
Explanation | An unexpected condition has occurred that no software subblock was previously allocated for a SWIDB. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-IDBBADTYPE : Datapath IDB type [dec] is not valid | |
---|---|
Explanation | An unexpected condition has occurred as the type of a datapath IDB is not valid. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-IDBEXIST : Datapath IDB already exists in this mapping entry: [chars]-[dec] | |
---|---|
Explanation | An unexpected condition has occurred that an attempt is made to save datapath IDB in a mapping entry filled by another. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-IDBNONEXIST : Datapath IDB does not exist in this mapping entry: [chars]-[dec] | |
---|---|
Explanation | Datapath IDB lookup points to empty mapping entry. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-RF : Datapath IDB RF operation failed — [chars] | |
---|---|
Explanation | Failure in some datapath ID RF activity. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-CF : Datapath IDB CF operation failed — [chars] | |
---|---|
Explanation | Failure in some datapath ID CF activity. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-RPC : Datapath IDB RPC operation failed — [chars] | |
---|---|
Explanation | Failure in some datapath ID RPC activity. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-REGISTRATION : ISSU [chars] failed for [chars]; [chars] | |
---|---|
Explanation | An ISSU registration for the set of initial capabilities and sessions failed due to the reason specified. This will have the effect of the DPIDX ISSU support being unavailable between peers. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-ISSU : [chars] [chars] failed; [chars] | |
---|---|
Explanation | An operation pertaining to the ISSU support for DPIDX failed to complete using either the CF or IPC transport context with the reason specified |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-TRANSFORM : [chars] of [chars] via [chars] failed for dpidx [int] | |
---|---|
Explanation | An attempt to either encode or decode a versioned synchronization message has failed due to an internal error encountered by the ISSU component. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-RECEIVE : Message via [chars] is [chars] | |
---|---|
Explanation | An attempt to receive and process a versioned negotiation or synchronization message has failed due to an internal error being detected by the information received from the IPC or CF components. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-TRANSMIT : Unable to send via [chars] [chars] [chars] [chars]; [chars] | |
---|---|
Explanation | An attempt to send a versioned negotiation or synchronization message has failed due to an internal error encountered by the IPC or CF components. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-NEGOTIATION : Failed to start ISSU [chars] session negotiation; [chars] | |
---|---|
Explanation | The ISSU negotiation with the peer failed to start for either the CF or IPC transport with the reason specified. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-6-READY : [chars] peer not ready, discarding [chars] | |
---|---|
Explanation | The synchronization attempt for the message has determined that the transport has lost communication with its peer. This is a normal situation which indicates that the standby route-processor is currently out of service implying a simplex redundancy mode. |
Recommended Action |
%IOSXE_RP_DPIDB-6-RELOAD : [chars], reloading [chars] | |
---|---|
Explanation | A synchronization attempt between the active and standby RP peers has failed with the reason indicated. The standby peer is reloaded in an attempt to resynchronize when operating in a stateful redundant mode. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-DECODE : Decode via [chars] of [chars] failed | |
---|---|
Explanation | A message of the transport and type described failed in its attempt to be decoded on the standby. The resultant action taken by the standby route processor is an attempt to resynchronize. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-PROGRESSION : Unable to inform RF of bulk sync completion; [chars] | |
---|---|
Explanation | The active route processor has sent a notification to the standby to inform of the completion of the bulk synchronization of the DPIDX configuration. The standby has failed to respond to the active informing that it received the notification noting the reason for the failure. The resultant action taken by the standby route processor is an attempt to resynchronize. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-BULK_SYNC : Failed to send [chars] information to peer | |
---|---|
Explanation | The bulk synchronization of the DPIDX configuration to the standby RP has failed to complete successfully; DPIDX has therefore taken the action which will result in a reload of the peer in order to once more attempt to successfully synchronize the configuration state which may have failed initially to a transient condition. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-DYN_SYNC : Failed to process [chars] dynamic state | |
---|---|
Explanation | The incremental synchronization of the DPIDX configuration to the standby RP has failed to complete successfully. This implies that the configuration state between the active and standby RP is inconsistent. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interfaces command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-6-TIMEOUT : Bulk sync is flow controlled by [chars] | |
---|---|
Explanation | The bulk synchronization of the DPIDX configuration to the standby RP has encountered a flow control condition which has effected a timeout awaiting the condition to clear. This will result in a reload of the standby RP to allow the bulk synchronization to restart. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-IDBNOTVAI : Invalid API call for [chars] | |
---|---|
Explanation | Failure in an internal API |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-NULLTIMER : NULL timer | |
---|---|
Explanation | A timer is NULL |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-LIST : List [chars] failed for [chars] | |
---|---|
Explanation | List enqueue or removal failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-FASTNOTIFY : Fast notify failed for [chars] | |
---|---|
Explanation | A fast notify message failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-DOWNLOADFAIL : Unable to download [chars] message to [chars] | |
---|---|
Explanation | An unexpected condition has occurred which resulted in a configuration not being sent to the reported process. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-FRRLDFLOWIDDELETIONFAILED : Deletion of fast-reroute flow ID with manager failed | |
---|---|
Explanation | An unexpected condition has occurred that deletion of fast-reroute flow ID. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-EFPSTATSFAILED : EFP stats message data get error: ([dec]) for EFP [int] on [chars] | |
---|---|
Explanation | An unexpected error occurred extracting fields from an EFP stats message. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_DPIDB-3-MTU_ALLOC_FAIL : No hardware resources for [int] byte MTU on [chars] | |
---|---|
Explanation | We reached to the threshold of maximum supported unique MTU on this platform. |
Recommended Action | No action is required. |
%IOSXE_RP_DPIDB-3-IP_MTU_ALLOC_FAIL : No hardware resources for [int] byte IP MTU on [chars] | |
---|---|
Explanation | We reached to the threshold of maximum supported unique IP MTU on this platform. |
Recommended Action | No action is required. |
IOSXE_RP_IF_FLOW_IDS
%IOSXE_RP_IF_FLOW_IDS-3-NO_BUFF_FOR_SYNC : The Checkpoint Faclity reported the error [chars] during a request for a buffer length of [dec]. This [chars] CF client has failed to synchronize a transaction to the Standby RP. |
|
---|---|
Explanation | This error indicates that the buffer management within the Checkpoint Facility has either run out of buffers, or has some other problem. If this occurs during Bulk Sync then Bulk Sync will terminate without completing. Otherwise the incremental Sync will fail. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-BUFF_OFFSET_NULL : Unable to utilize the memory buffer provided by the Checkpoint Facility. This [chars] CF client has failed to Bulk Sync. |
|
---|---|
Explanation | This error indicates the Checkpoint Facility is having problems recognizing its own buffer layout. If this occurs during Bulk Sync then Bulk Sync will terminate without completing. Otherwise the incremental Sync will fail. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-CF_SEND_BULK_NONBLOCKED : The Checkpoint Facility reported the error [chars] while attempting to send a message. Bulk Sync of this [chars] CF client is terminating. |
|
---|---|
Explanation | This error indicates the Checkpoint Facility has internal problems related to IPC, and cannot perform a non-blocked send operation. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-DEFERRED_DURING_BULK_SYNC : Encountered error [chars] while trying to place an [chars] transaction on the Deferred list during Bulk Sync for the [chars] CF client. |
|
---|---|
Explanation | Unable to cache a deferred transaction while Bulk Sync is underway. This can adversely impact SSO state on the Standby RP. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-CF_SEND_INCR_NONBLOCKED : The Checkpoint Facility reported the error [chars] while attempting to send a non-blocked message. The Incremental Sync transaction for this [chars] CF client cannot be sent to the Standby RP. |
|
---|---|
Explanation | This error indicates the Checkpoint Facility has internal problems related to IPC. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-6-CFPEER_CANNOT_RECV : The Checkpoint Peer is not ready to receive messages. The Incremental Sync transaction for this [chars] CF client will not occur. |
|
---|---|
Explanation | This error indicates the Checkpoint Facility has signalled the peer has gone away. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-SEND_FAIL_RELOAD : Checkpoint Facility Failed to send a [chars] transaction for this [chars] CF client. Reloading the Standby RP. |
|
---|---|
Explanation | This indicates the underlying Checkpoint Facility could not deliver a message sent from the active RP to the standby RP. The process will automatically reload the standby RP. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-4-DEF_LIST_REMOVE : Failed to remove one entry from the Deferred Sync list, for the [chars] CF client. | |
---|---|
Explanation | An unexpected condition occured during list maintenance. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-CF_CANNOT_REGISTER : The call to add this [chars] CF client to the Checkpoint Facility failed with the error [chars]. This client is unable to proceed and will not be registered. |
|
---|---|
Explanation | For some reason the Checkpoint Facility will not register this client. As a result the Standby will never receive synchronized state from this CF client on the Active RP, The system is not capable of SSO and HA switchover. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-RF_PEER_EVENT_BUFFER : This [chars] RF client is unable to acquire an event buffer to send an RF peer message, the error [chars] was returned. |
|
---|---|
Explanation | This indicates the RF facility is unable to provide a message buffer needed to communicate with the RF peer. As a consequence the RF progression may be compromised. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-RF_SEND_PEER : This [chars] RF client encountered error [chars], when attempting to send a peer message. | |
---|---|
Explanation | This indicates the RF facility could not send a message to the RF peer. As a consequence the RF progression may be compromised. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-RF_PROCESS_FAILED : This [chars] RF client Failed to create the Bulk Sync Process. | |
---|---|
Explanation | The background process which performs the RF Bulk Sync failed to be created. As a consequence the Standby will never obtain the relevent SSO state to enable HA switchover. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-RF_POOL_REGEN_PROCESS_FAILED : The [chars] RF client Failed to create the Id Pool Regeneration process. | |
---|---|
Explanation | The background process which performs Flow Control Id Pool regeneration failed to start. As a consequence the Standby will never obtain the relevent SSO state to enable HA switchover. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-RF_POOL_REGEN_ERROR : Id Pool Regeneration encountered error code [dec], cannot switchover. | |
---|---|
Explanation | The background process which performs Flow Control Id Pool regeneration encountered an error. As a consequence the Standby does not have valid Flow Id pools and cannot progress to Active state. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-RF_SPA_ID_REGEN_ERROR : Error code [dec] encountered trying to regenerate spa [chars] identifier in slot/subslot ([int]/[int]) |
|
---|---|
Explanation | The background process which performs Flow Control Id Pool regeneration encountered an error. As a consequence the Standby does not have valid Id pools and cannot progress to Active state. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-RF_IF_ID_REGEN_ERROR : Error code [dec] encountered trying to regenerate interface flow-control identifer. If id [int] resides in slot/subslot/port ([int]/[int]/[int]). |
|
---|---|
Explanation | The background process which performs Flow Control Id Pool regeneration encountered an error. As a consequence the Standby does not have valid Id pools and cannot progress to Active state. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-RF_ADD_CLIENT_FAILED : The RF facility failed to add this [chars] client, reason given is [chars]. | |
---|---|
Explanation | This indicates the RF facility could not add the client. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-REGISTRATION : ISSU [chars] failed for [chars]; [chars] | |
---|---|
Explanation | An ISSU registration for the set of initial capabilities and sessions failed due to the reason specified. This will have the effect of the SPA MARMOT ID ISSU support being unavailable between peers. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-ISSU_OP : [chars] [chars] failed; [chars] | |
---|---|
Explanation | An operation pertaining to the ISSU support for SPA MARMOT IDs failed to complete using the CF transport context with the reason specified |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-TRANSFORM : [chars] of [chars] via CF failed | |
---|---|
Explanation | An attempt to either encode or decode a versioned synchronization message has failed due to an internal error encountered by the ISSU component. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-TRANSMIT : Unable to send via [chars] [chars] [chars] [chars]; [chars] | |
---|---|
Explanation | An attempt to send a versioned negotiation or synchronization message has failed due to an internal error encountered by the CF component. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-NEGOTIATION : Failed to start ISSU [chars] session negotiation; [chars] | |
---|---|
Explanation | The ISSU negotiation with the peer failed to start for either the CF or IPC transport with the reason specified. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-6-READY : [chars] peer not ready, discarding [chars] | |
---|---|
Explanation | The synchronization attempt for the message has determined that the transport has lost communication with its peer. This is a normal situation which indicates that the standby route-processor is currently out of service implying a simplex redundancy mode. |
Recommended Action |
%IOSXE_RP_IF_FLOW_IDS-3-DECODE : Decode via CF of [chars] failed | |
---|---|
Explanation | A message sent via the CF transport failed in its attempt to be decoded on the standby. The resultant action taken by the standby route processor is an attempt to resynchronize. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_IF_FLOW_IDS-3-RECEIVE : Client reports message CF is [chars] | |
---|---|
Explanation | An attempt to receive and process a versioned negotiation or synchronization message has failed due to an internal error being detected by the information received from the CF component. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_RP_MGMTE through IOSXE_TIMESTAMP_ENGINE
-
IOSXE_RP_MGMTE
-
IOSXE_RP_NV
-
IOSXE_RP_SPA
-
IOSXE_RP_VTYMGT
-
IOSXE_SERVICE_ENGINE
-
IOSXE_SIP_SPA
-
IOSXE_SPA
-
IOSXE_SYS_INFRA
-
IOSXE_THROUGHPUT
-
IOSXE_TIMESTAMP_ENGINE
IOSXE_RP_MGMTE
%IOSXE_RP_MGMTE-3-MSGCREATENULL : Cannot allocate [chars] TDL message | |
---|---|
Explanation | An unexpected condition in which IOS cannot allocate TDL message for Management ethernet. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_MGMTE-3-MSGTDLINITERROR : Management ethernet interface messaging module initialization failed: Unable to initialize messaging: [chars] |
|
---|---|
Explanation | The Management ethernet interface subsystem has failed to initialize the infrastructure for messaging with the Pluggable Services Daemon. Configuration of management ethernet modules cannot proceed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_MGMTE-3-PROCESS_CREATE_FAIL : Management ethernet statistics process creation failed | |
---|---|
Explanation | Can not create IOS process for RP management ethernet port statistics collection |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_MGMTE-3-MGMT_MAC_MODIFY_FAIL : Management ethernet interface mac address modification failed | |
---|---|
Explanation | Can not override mac-address for management ethernet interface |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_RP_NV
%IOSXE_RP_NV-3-NV_ACCESS_FAIL : Initial read of NVRAM contents failed | |
---|---|
Explanation | This error happens when the contents of the NVRAM cannot be read during system initialization. The failure may be due to data corruption of the NVRAM contents. The initial configuration dialog will be entered and the configuration must be restored. |
Recommended Action | LOG_STD_ACTION |
%IOSXE_RP_NV-3-BACKUP_NV_ACCESS_FAIL : Initial read of backup NVRAM contents failed | |
---|---|
Explanation | This error happens when the contents of the backup NVRAM cannot be read during system initialization. The failure may be due to data corruption of the backup NVRAM contents. The primary nvram contents will be backed up here again. |
Recommended Action | LOG_STD_ACTION |
IOSXE_RP_SPA
%IOSXE_RP_SPA-3-SEND_NGIO_MSG_FAIL : NGIO Module message send failed for slot [dec] subslot [dec] | |
---|---|
Explanation | Failed to send ngio msg to iomd. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-3-MAC_FILTER_ADD_FAIL : All the available [dec] mac filters for [chars] have been consumed. Failed to add [enet] for interface [chars] |
|
---|---|
Explanation | The hardware cannot support any more filters. |
Recommended Action | The interface configuration should be reworked to not cross the limit set by the hardware. If the error is still seen please LOG_STD_SH_TECH_ACTION |
%IOSXE_RP_SPA-3-SEND_L2_HDR_MSG_FAIL : slot [dec] subslot [dec] | |
---|---|
Explanation | Failed to send ngio L2 header to iomd. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-3-NO_HOST_INFO : slot [dec] subSlot [dec], spaType [hex] | |
---|---|
Explanation | Failed to get information about the host linecard. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-3-MAX_SPA : Power to IPSEC-SPA-2G in [chars] is denied because it has exceeded the number allowed([dec]) | |
---|---|
Explanation | The number of IPSEC-SPA-2G in a chassis is limited. This message is displayed when the number of IPSEC-SPA-2G in the chassis has exceeded this limit. |
Recommended Action | Use only the number of supported IPSEC-SPA-2G |
%IOSXE_RP_SPA-3-SPA_NO_HOST_INFO : slot [dec] subSlot [dec], PID [chars] | |
---|---|
Explanation | Failed to get information about the host linecard. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-3-HWIDB_FAILURE : Creation: slot [dec] subSlot [dec] port [dec] vc [dec] | |
---|---|
Explanation | Failed to create an interface hwidb. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-3-INVALID_PORT_NUM : slot=[dec] port=[dec], hwidbType=[hex], max_port_num=[dec], LCtype=[hex] | |
---|---|
Explanation | The port number is out of range. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-4-SPA_RESP_CMD_MISMATCH : [chars]: Expecting response to interface configuration command [int] but received response to command [int]. |
|
---|---|
Explanation | An internal synchronization error occurred while configuring the interface. The configuration may not have succeeded. |
Recommended Action | Check that the running configuration for the interface is correct. If this message occurred on the standby, try reloading the standby to ensure that its configuration is in sync. If this message is repeatable, please LOG_STD_SH_TECH_ACTION |
%IOSXE_RP_SPA-6-CARDRELOAD : Module [int] reload due to SPA insert in [int]/[int]. | |
---|---|
Explanation | When inserting a SPA on this carrier card, the card is reset. |
Recommended Action | No action is required. |
%IOSXE_RP_SPA-6-CTRLRSWITCH : switching controller type from [chars]([dec]) to [chars]([dec]) for subslot [int]/[int]. | |
---|---|
Explanation | When IOSXE-SIP40 is inserted in the slot previously occupied by IOSXE-SIP10 or vice-versa the controller type of the card is overwritten to reflect the current SIP. |
Recommended Action | No action is required. |
%IOSXE_RP_SPA-4-SPA_CMD_NO_RESP : [chars]: No response for interface configuration command [int] | |
---|---|
Explanation | A timeout occurred while RP was waiting for a response from line card. This may happen due to line card CPU being too busy to respond to the command. |
Recommended Action | No action is required. |
%IOSXE_RP_SPA-3-IPCALLOCFAIL : Failed to allocate IPC buffer [chars] | |
---|---|
Explanation | The RP failed to allocate a buffer for communication with a SPA |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-3-DPIDX_LKUP_FAIL : Failed to retrieve datapath identifier for interface [chars] | |
---|---|
Explanation | The SPA driver is not able to retrieve the datapath identifier for the interface specified in the message. This indicates a software error. |
Recommended Action | No action is required. |
%IOSXE_RP_SPA-3-FLOWID_ALLOC_FAIL : Failed to allocate a flow control identifier for interface [chars] | |
---|---|
Explanation | The SPA driver is not able to allocate the datapath flow control identifier for the interface specified in the message. This indicates a software error. |
Recommended Action | No action is required. |
%IOSXE_RP_SPA-3-FLOWID_RELEASE_FAIL : Failed to release a flow control identifier for interface [chars] (status = [dec]) | |
---|---|
Explanation | The SPA driver is not able to release the datapath flow control identifier for the interface specified in the message. This indicates a software error. |
Recommended Action | No action is required. |
%IOSXE_RP_SPA-3-VC_PROV_FAIL : Failed to provision interface [chars] | |
---|---|
Explanation | The SPA driver is not able to provision the interface specified in the message. Verify that the SPA hardware is not provisioned above the supported limit. Otherwise, this indicates a hardware error. |
Recommended Action | No action is required. |
%IOSXE_RP_SPA-3-CI_UPDATE_FAIL : Failed to update connection identifier for interface [chars] | |
---|---|
Explanation | The SPA driver is not able to update the datapath connection identifier for the interface specified in the message. This indicates a software error. |
Recommended Action | No action is required. |
%IOSXE_RP_SPA-3-NULL_DATA_STRUCTURE : common_str_empty_str | |
---|---|
Explanation | A SPA driver is not able to retrieve the data structure mentioned in the message. This indicates a software error. |
Recommended Action | No action is required. |
%IOSXE_RP_SPA-3-HWIDB_INIT_FAIL : Failed to initialize data structure for SPA port [dec]/[dec]/[dec] | |
---|---|
Explanation | A SPA driver was not able to properly initialize a data structure mentioned in the message. This indicates a software error. |
Recommended Action | No action is required. |
%IOSXE_RP_SPA-3-ERROR : common_str_empty_str | |
---|---|
Explanation | This message can take many forms. It provides information about a software error. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-4-LCLOG_TOOLONG : Message too long from slot [int]/[int]: [int] bytes | |
---|---|
Explanation | The SPA module passed down a logger message that is too long for the RP to handle. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-4-LCLOG_PARSE_ERR : Error parsing logger message: [chars] from subslot [int]/[int] | |
---|---|
Explanation | The SPA module passed down a logger message that could not be parsed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-3-BAD_IFCOMTYPE : Bad ifcom message type=[int] | |
---|---|
Explanation | A SPA module passed down a message that the RP software was not prepared to handle. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-4-IPCFAILED : IPC failed to send RPC message to SPA module | |
---|---|
Explanation | The RP failed to send an RPC message via IPC to a SPA module. |
Recommended Action | No action is required. |
%IOSXE_RP_SPA-3-FOREVER : cmd [int] to [chars] (slot [int]/[int]) took [int]secs, done [hex] | |
---|---|
Explanation | A CCB command from the RP to a SPA module took longer than expected. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-4-SEMAHOG : Process [dec] ([chars]) hogging [chars]! calling proc [dec] ([chars]) | |
---|---|
Explanation | The RP waited too long for a reply to a command sent to a SPA module. |
Recommended Action | No action is required. |
%IOSXE_RP_SPA-3-IPCPORTFAIL : Failed to open IPC port ‘[chars]’ with error [chars] | |
---|---|
Explanation | The RP failed to open a port for communication with a SPA module. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-4-CCB_PLAYBACK_ERROR : CCB playback failed for slot [dec]. | |
---|---|
Explanation | The High Availability component for SPA modules failed to synchronize some new state information for the specified slot. |
Recommended Action | Reload the standby supervisor module to force a fresh bulk synchronization. If this error recurs, LOG_STD_ACTION |
%IOSXE_RP_SPA-4-CCB_RECORD_ERROR : CCB record failed for slot [dec]. | |
---|---|
Explanation | The High Availability component for SPA modules failed to record some new state information for the specified slot. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-3-IPCSENDFAIL : Failed to send IPC message [chars] | |
---|---|
Explanation | The RP failed to send a message to a SPA module. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-3-IFCFG_NO_UNIQUE_KEY : No unique-key generator registered for interface configuration command [int]. | |
---|---|
Explanation | The High Availability component for SPA modules is unable to properly synchronize state information for the current configuration. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-3-IFCFG_FOREVER : to [chars] (slot [int]/[int]) took [int]secs, ret_val [int] | |
---|---|
Explanation | A interface config command from the RP to a SPA module took longer than expected. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-4-IFCFG_CMD_TIMEOUT : Interface configuration command ([hex]) to slot [int]/[int] timed out | |
---|---|
Explanation | The RP sent an configuration command to the slot specified in the error message and received no confirmation for the command. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-3-IFCFG_CMD_NOT_OWNER : Process ‘[chars]’ waiting for interface configuration command ([hex]) to slot [int]/[int] without acquiring lock owned by process ‘[chars]’ |
|
---|---|
Explanation | A process on the RP sent an configuration command to the slot specified in the error message and a different process waited for the result. This could cause incorrect line card configuration states. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-4-IFCFG_DFLT_LIST_ERROR : For Interface Configuration command [int], default retval list search resulted [hex] for slot [int]/[int] |
|
---|---|
Explanation | The High Availability component for SPA modules failed to synchronize some new state information for the specified slot. |
Recommended Action | LOG_STD_SH_CMD_ACTION(show platform redundancy if-config default-retvals) |
%IOSXE_RP_SPA-4-IFCFG_PLAYBACK_ERROR : Interface Configuration command [int] playback failed for slot [int]/[int]. | |
---|---|
Explanation | The High Availability component for SPA modules failed to synchronize some new state information for the specified slot. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-4-IFCFG_RECORD_ERROR : Interface Configuration command [int] record failed for slot [int]/[int]. | |
---|---|
Explanation | The High Availability component for SPA modules failed to record some new state information for the specified slot. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-4-INCR_CFG_SYNC_FAIL : [chars] incremental running-config sync for [[dec]/[dec]] failed — [chars]([dec]) , Reload Standby |
|
---|---|
Explanation | The specified IOSXE incremental running-config sync failed |
Recommended Action | Power cycle the redundant supervisor |
%IOSXE_RP_SPA-3-IPCPORT : Failed to [chars] IPC port ‘[chars]’, error [chars] | |
---|---|
Explanation | The Linecard failed to create a port for communication with the Route Processor (IOSXE-RP). |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IOSXE_RP_SPA-3-PROGRESSION : Unable to inform RF of bulk sync completion; [chars] | |
---|---|
Explanation | The standby has failed to notify the active that its bulks synchronization of the SPA TSM has completed. The resultant action taken by the standby route processor is an attempt to resynchronize. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-3-VC_FLOWID_ALLOC_FAIL : Failed to allocate a flow control identifier for VC [dec] under interface [chars] | |
---|---|
Explanation | The SPA driver is not able to allocate the datapath flow control identifier for the VC/interface specified in the message. This indicates a software error. |
Recommended Action | No action is required. |
%IOSXE_RP_SPA-3-VC_INGID_ALLOC_FAIL : Failed to allocate a ingress identifier for VC [dec] interface [chars] | |
---|---|
Explanation | The SPA driver is not able to allocate the datapath ingress identifier for the VC/interface specified in the message. This indicates a software error. |
Recommended Action | No action is required. |
%IOSXE_RP_SPA-4-SPA_RESP_CMD_ERR : [chars]: Received response to interface configuration command [chars] with wrong return value [int]. |
|
---|---|
Explanation | An internal error occurred while configuring the interface. The configuration may not have succeeded. |
Recommended Action | Check that the running configuration for the interface is correct. If this message is repeatable, please LOG_STD_SH_TECH_ACTION |
%IOSXE_RP_SPA-3-FRR_CFG_REC_FAIL : Failed to record fast reroute conifguration on [chars]: [chars] | |
---|---|
Explanation | This message is displayed when a fast reroute configuration is not properly recorded. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-3-MISSING_SPA_PKG_ERR : sipspa[chars] package is not installed for slot = [dec] and subslot = [dec], SPA bootup failed. |
|
---|---|
Explanation | This message is displayed when attempting to bootup a SPA without installing a subpackage required for the same. |
Recommended Action | Download the sub-package required for the affected SPA from the Cisco CCO software download site and install the same. This SPA can be booted in sub-package mode only. Please refer to the Cisco ASR platform documentation for obtaining and installing sub-packages. |
%IOSXE_RP_SPA-3-UNSUPPORTED_SRVCS_SPA : Service SPA ([hex]) in [dec]/[dec] is not supported. SPA bootup failed. | |
---|---|
Explanation | This message is displayed when attempting to bootup any service SPA in router running non K9 image, i.e., non-crypto image. |
Recommended Action | Download the K9 IOS XE sub-packages and the required sub-package for the given service SPA from the Cisco CCO software download site and install the same. This SPA can be booted in sub-package mode only. Please refer to the Cisco ASR platform documentation for obtaining and installing sub-packages. |
%IOSXE_RP_SPA-3-MISSING_SPA_PKG_WARN : sipspa[chars] package is not installed in standby for slot = [dec] and subslot = [dec]. | |
---|---|
Explanation | This message is displayed in standby console when attempting to bootup or restart or reload a WMA SPA without installing a subpackage in the standby RP, although the SPA is or will be operational due to prior wma spa package installation in active RP. If switchover takes place the WMA SPA will still be operational. But any subsequent soft or hard oir of the SPA will fail due to missing sub package required to boot up the SPA. Hence it is recommended to complete the wma spa package installation in standby also before switchover or immidiately after switchover. |
Recommended Action | Download the sub-package required for the affected SPA from the Cisco CCO software download site and install the same for the standby RP as is done on active RP. Please refer to the Cisco ASR platform documentation for obtaining and installing sub-packages. |
%IOSXE_RP_SPA-3-SPA_WRONGTYPE : Mismatched SPA type ([dec]) in slot [dec]/[dec]. Expected type [dec]. Use ‘no card [dec]/[dec]’ command to override preprovisioning and update card type. |
|
---|---|
Explanation | The SPA inserted does not match the currently provisioned SPA type. |
Recommended Action | Replace wrong SPA with currently provisioned SPA type, or type ‘no card’ to allow new card type to be discovered. |
%IOSXE_RP_SPA-6-MEDIA_AUTOFAILOVER : Media Fail over from ([chars]) to ([chars]) | |
---|---|
Explanation | Gige Media Failover. |
Recommended Action | This is inforamtional message, Not an error message. Use ‘show interface gig’ to see the current active media type. |
%IOSXE_RP_SPA-3-SONET_ALARM_PROC_ERR : [chars] Error has occurred while processing in the sonet alarm-proc | |
---|---|
Explanation | Either free/create of the memory failed in SONET alarm proc |
Recommended Action |
%IOSXE_RP_SPA-3-LIC_REQ_FAILED : [int]/[int]/[int]: Interface enable not allowed — license request failed , err=[hex] | |
---|---|
Explanation | A 10 Gig License is required to enable this port. License request has been denied by license manager |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-3-LIC_REL_FAILED : [int]/[int]/[int]: Failed to release license feature [chars], handle=[hex], err=[hex] | |
---|---|
Explanation | License release has been denied by license manager |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_SPA-3-LIC_REG_FAILED : [int]/[int]/[int]: Failed to register license feature [chars], err=[hex] | |
---|---|
Explanation | License registration has been denied by license manager |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_RP_VTYMGT
%IOSXE_RP_VTYMGT-3-MSGDISPATCHNULL : Received NULL TDL message | |
---|---|
Explanation | An unexpected condition in which IOS has received a NULL TDL message for Vty Management. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_VTYMGT-3-MSGDISPATCH : Unable to dispatch received TDL messages for Vty Management | |
---|---|
Explanation | An unexpected condition has occurred while IOS is trying to dispatch to the TDL message handler functions for received TDL messages for Vty Management. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_VTYMGT-3-MSGMISSINGFIELD : Missing field ‘[chars]’ in TDL Vty Management message ‘[chars]’ received | |
---|---|
Explanation | A message missing a required field was received for Vty Management |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_VTYMGT-3-MSGINVALIDFIELDINT : Invalid field ‘[chars]’ in TDL message ‘[chars]’ received: value ‘[int]’ for Vty Management |
|
---|---|
Explanation | A message with an invalid field value was received for Vty Management |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_VTYMGT-3-MSGINVALIDFIELDSTR : Invalid field ‘[chars]’ value ‘[chars]’ in TDL message ‘[chars]’ received for Vty Management |
|
---|---|
Explanation | A message with an invalid field value was received for Vty Management |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_VTYMGT-3-MSGERROR : Error ‘[dec]’ handling a received TDL message ‘[chars]’ for Vty Management: [chars] | |
---|---|
Explanation | An unexpected condition has occurred while IOS is processing a received Vty Management TDL message |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_VTYMGT-3-MSGBUILDERROR : Error ‘[dec]’ building TDL Vty Management message ‘[chars]’: [chars] | |
---|---|
Explanation | An unexpected condition has occurred while IOS is building a TDL response message for Vty Management |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_VTYMGT-3-MSGMARSHALERROR : Error ‘[dec]’ marshaling TDL Vty Management message ‘[chars]’: [chars] | |
---|---|
Explanation | An unexpected condition has occurred while IOS is marshaling TDL response message for Vty Management |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_VTYMGT-3-MSGENQUEUEERROR : Error queueing TDL Vty Management message ‘[chars]’ | |
---|---|
Explanation | An unexpected condition has occurred when IOS attempted to queue a TDL response message for Vty Management |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_VTYMGT-3-MSGBIPCERR : Unable to process received BIPC messages for Vty Management, error: [chars] | |
---|---|
Explanation | An unexpected condition has occurred while IOS was trying to process a received BIPC message for Vty Management. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_VTYMGT-3-MSGBIPCBUFFER : Unable to acquire a BIPC buffer of length [dec] for sending messages. | |
---|---|
Explanation | A message was to be sent by IOS, but no BIPC buffer was available. The message to be sent has been discarded and the associated operation failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_VTYMGT-3-MSGEXTAPPUPDATE : Unable to update external application data for line ‘[dec]’ | |
---|---|
Explanation | An attempt to update the external application for a line failed unexpectedly. The line update failed and if the line number specified is valid, the line was released. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_VTYMGT-3-MSGVTYSVCINIT : Unable to initialize the Vty Management service listen port | |
---|---|
Explanation | The platform IPC services failed to register the Vty Management service’s need for a listen port. The Vty Management service will be unable to process requests. IOS services will be unavailable to external access methods. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_VTYMGT-3-MSGVTYCOUNT : Invalid vty count [dec] detected on initialization | |
---|---|
Explanation | Upon initialization, the Vty Management subsystem checks that the number of available vtys for the platform is valid. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_RP_VTYMGT-3-SET_ACCESS_FAIL : Installing LIIN interface access control failed | |
---|---|
Explanation | This error happens when the Vty Management subsystem failed to set the access control function for the LIIN, possibly due to IOS out of memory or corruption. Persistent access features into IOS will not work. |
Recommended Action | LOG_STD_ACTION |
IOSXE_SERVICE_ENGINE
%IOSXE_SERVICE_ENGINE-3-MSGOPENFAIL : Cannot open interface [chars] ([dec]) | |
---|---|
Explanation | During the creation of a Service-Engine interface, it is necessary to program the system parameters in the driver. The driver cannot be opened. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SERVICE_ENGINE-3-MSGSETFAIL : Set id on interface [chars] ([dec]) | |
---|---|
Explanation | During the creation of a Service-Engine interface, it is necessary to program the system parameters in the driver. The failed to accept the programming. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SERVICE_ENGINE-3-MSGINITFAIL : Initialization of interface [chars] failed | |
---|---|
Explanation | The initialization of the interface mentioned in the error message has failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_SIP_SPA
%IOSXE_SIP_SPA-3-HWIDB_FAILURE : Creation: port [dec] vc [dec] | |
---|---|
Explanation | Failed to create a hwidb. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SIP_SPA-3-DEVICE_ERROR : subSlot [dec], spatype [hex]. Device error: [chars] | |
---|---|
Explanation | An error related to a device on the SPA is detected. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SIP_SPA-3-ISR_RC_ERROR : ISR return code out of range. rc=[dec] | |
---|---|
Explanation | The ISR error return code is out of range. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SIP_SPA-3-SPA_INTF_ID_CC_ALLOC_FAILED : Failed to allocate interface identifiers for SPA ([chars]) in slot/bay: [int]/[int] | |
---|---|
Explanation | Failed to get CC buffer and flow control identifiers for the SPA in the specified subslot Traffic cannot flow through the SPA under this failure condition. This can happen if the system runs out of available identifiers. |
Recommended Action | Try to reduce the number of interfaces configured in the system either by physically removing the SPAs or by changing the system configuration |
%IOSXE_SIP_SPA-4-SPABUS : Subslot [dec], [chars] SPA BUS access failed. timeout=[int] err=[int] par=[int] err_c=[hex] addr=[hex] data =[hex] |
|
---|---|
Explanation | SPABUS has reported an error. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SIP_SPA-4-SPABUS2 : Subslot [dec] SPA BUS access failed. No SPA present error | |
---|---|
Explanation | SPABUS has reported an error. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SIP_SPA-6-OIR : Bay [dec] [chars] changed to [chars] | |
---|---|
Explanation | SPA OIR Sequence |
Recommended Action | No action is required. |
%IOSXE_SIP_SPA-4-MAX_BANDWIDTH : Total SPA bandwidth exceeds line card capacity of [int] Mbps | |
---|---|
Explanation | The total bandwidth of SPAs exceeds the rated capacity of this line card. |
Recommended Action | Refer to the line card guidelines for the maximum allowed aggregated SPA bandwidth for the line card |
%IOSXE_SIP_SPA-4-MAX_BANDWIDTH_NS : Total SPA bandwidth exceeds line card capacity, full utilization of installed SPA interfaces is not supported |
|
---|---|
Explanation | The total bandwidth of SPAs exceeds the rated capacity of this line card. |
Recommended Action | Refer to the line card guidelines for the maximum allowed aggregated SPA bandwidth for the line card |
%IOSXE_SIP_SPA-3-POWER : Bay [dec] 12V power is [chars] | |
---|---|
Explanation | SPA 12V power fault indicator |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SIP_SPA-3-SPI4_INIT_FAILURE : Bay [dec] initialization failure | |
---|---|
Explanation | Failed to create SPI4 subblock |
Recommended Action | Seach for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, LOG_STD_ACTION |
%IOSXE_SIP_SPA-3-MESSAGE_ERROR : Bay [dec]: [chars] | |
---|---|
Explanation | An unexpected error has occurred. |
Recommended Action | Seach for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, LOG_STD_ACTION |
%IOSXE_SIP_SPA-3-SPI4_CONFIG_FAILURE : Bay [dec], spi4 configuration failure, error [dec] | |
---|---|
Explanation | Failed to configure SPI4 interface |
Recommended Action | Seach for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, LOG_STD_ACTION |
%IOSXE_SIP_SPA-3-SPI4_NOTSYNC : [chars]: Can not synchronize SPI4 bus (host: src [chars]in sync, sink [chars]in sync, spa: src [chars]in sync, sink [chars]in sync). |
|
---|---|
Explanation | SPI4 bus between modular services card and SPA is not synchronized. It indicates either a not properly seated SPA, a hardware failure or an outdated ROMMON/FPGA image. |
Recommended Action | Ensure that the SPA is properly seated in its subslot and reseat it if required. |
%IOSXE_SIP_SPA-3-SPA_CTRL_INIT_FAILURE : Subslot [dec], spa controller initialisation failure, error [dec] | |
---|---|
Explanation | Failed to initialise SPA controller |
Recommended Action | Seach for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, LOG_STD_ACTION |
%IOSXE_SIP_SPA-3-SPA_CTRL_EFC_CONFIG_FAILURE : Subslot, spa controller EFC configuration failure, error [dec] | |
---|---|
Explanation | Failed to configure SPA controller EFC |
Recommended Action | Seach for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, LOG_STD_ACTION |
%IOSXE_SIP_SPA-3-FCI_NOT_SET : Bay [dec] — FCI type not set | |
---|---|
Explanation | An FCI type of zero was detected |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SIP_SPA-3-EFC_CHAN_ERR : EFC error — interface [chars], vc [dec], anyphy [dec], err_code [dec] : [chars] | |
---|---|
Explanation | Failed to configure efc channel/parameters |
Recommended Action | Seach for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, LOG_STD_ACTION |
%IOSXE_SIP_SPA-3-INVALID_ANYPHY : Bay [dec] — Invalid anyphy number [int] for vc [dec] | |
---|---|
Explanation | Interface has invalid anyphy mumber |
Recommended Action | Seach for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case or contact your Cisco technical support representative. Be sure to provide the the information you have gathered and a ‘show tech-support’ to your support representative, or attach it to your case in non-zipped, plain text format (.txt). |
%IOSXE_SIP_SPA-3-LINKREC_ERROR : Link record error — Bay [dec] vc [dec], error code [dec] | |
---|---|
Explanation | Error processing link record structure |
Recommended Action | Seach for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case or contact your Cisco technical support representative. Be sure to provide the the information you have gathered and a ‘show tech-support’ to your support representative, or attach it to your case in non-zipped, plain text format (.txt). |
%IOSXE_SIP_SPA-3-SONET_CLOCK_FAILED : SPA Sonet clock has failed (status = [hex]) | |
---|---|
Explanation | The SPA SONET clock has failed. SPAs that rely on the SPA SONET clock for proper operation, such as POS and ATM will be affected. |
Recommended Action | If the SPA Sonet clock does not recover, perform an OIR. LOG_STD_RECUR_ACTION |
%IOSXE_SIP_SPA-3-SONET_CLOCK_RECOVERED : SPA Sonet clock has recovered (status = [hex]) | |
---|---|
Explanation | SPA Sonet clock has recovered |
Recommended Action | No action is required. |
%IOSXE_SIP_SPA-3-INVALID_IF : Attempted to access HWIDB for port [int] on slot [dec] subSlot [dec] | |
---|---|
Explanation | The ASR1000 attempted to access the HWIDB associated with a non-existent port. |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IOSXE_SIP_SPA-3-ASR1000IPCALLOCFAIL : Failed to allocate Common IPC buffer [chars] | |
---|---|
Explanation | The Carrier Card failed to allocate a buffer for communication with the Route Processor. |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IOSXE_SIP_SPA-3-CMDNOINT : HWIDB Null for command [dec], port [hex] | |
---|---|
Explanation | The Route Processor passed down a port number that is unknown on the carrier card. |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IOSXE_SIP_SPA-3-EFC_FC_MAP_FAIL : Failed to update EFC flow control identifier for interface [chars] (status = [dec]) | |
---|---|
Explanation | The SPA driver is not able to update the datapath EFC flow control identifier for the interface specified in the message. This indicates a hardware error. |
Recommended Action | No action is required. |
%IOSXE_SIP_SPA-3-EFC_PROV_FAIL : Failed to provision EFC for interface [chars] (status = [dec]) | |
---|---|
Explanation | The SPA driver is not able to provision EFC for the interface specified in the message. This indicates a hardware error. |
Recommended Action | No action is required. |
%IOSXE_SIP_SPA-3-EFC_UNPROV_FAIL : Failed to unprovision EFC for VC [chars] (status = [dec]) | |
---|---|
Explanation | The SPA driver is not able to unprovision EFC for the interface specified in the message. This indicates a hardware error. |
Recommended Action | No action is required. |
%IOSXE_SIP_SPA-3-C2W_MAIN_INIT_FAIL : Failed to initialize SPA main c2w bus for subslot [dec] (status = [dec]) | |
---|---|
Explanation | The SPA driver is not able to initialize SPA main c2w. This indicates a hardware error. |
Recommended Action | No action is required. |
%IOSXE_SIP_SPA-3-NETCLK_FAIL : Failed to [chars] SPA reference clock on [chars] | |
---|---|
Explanation | The SPA driver is not able to correctly configure the SPA reference clock on the specified interface. This indicates a hardware error. |
Recommended Action | No action is required. |
%IOSXE_SIP_SPA-3-LVLTRTOOBIG : Loveletter length exceeds max, [int] bytes | |
---|---|
Explanation | The ASR1000-SIP line card attempted to send a large message to the Route Processor (ASR1000-RP). |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IOSXE_SIP_SPA-3-NODISPATCH : Dispatch vector Null, cmd=[dec], dintf=[dec] | |
---|---|
Explanation | No command dispatch vector was found for the specified interface. |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IOSXE_SIP_SPA-3-BADMALUCMD2 : Unsupported MALU cmd/arg0=[hex][hex], arg1arg2=[hex][hex] , hwidb=[chars] | |
---|---|
Explanation | The Route Processor (ASR1000-RP) passed down a command that the software was not prepared to handle. |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IOSXE_SIP_SPA-3-BADMALUCMD : Unsupported MALU command [dec], arg=[hex], pascb=[hex] | |
---|---|
Explanation | The Route Processor (ASR1000-RP) passed down a command that the software was not prepared to handle. |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IOSXE_SIP_SPA-3-BAD_IFCOMTYPE : Bad ifcom message type=[int] | |
---|---|
Explanation | The Route Processor (ASR1000-RP) passed down a message that the software was not prepared to handle. |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IOSXE_SIP_SPA-3-IPCSENDFAIL : Failed to send IPC message [chars] | |
---|---|
Explanation | The Linecard failed to send a message to the Route Processor (ASR1000-RP). |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IOSXE_SIP_SPA-3-IPCALLOCFAIL : Failed to allocate IPC buffer [chars] | |
---|---|
Explanation | The SPA failed to allocate a buffer for communication with the Route Processor (ASR1000-RP). |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IOSXE_SIP_SPA-3-IPCPORTFAIL : Failed to open IPC port ‘[chars]’ [chars] with error [chars] | |
---|---|
Explanation | The RP failed to open a port for communication with a SPA module. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SIP_SPA-3-IPCPORT : Failed to [chars] IPC port ‘[chars]’, error [chars] | |
---|---|
Explanation | The Linecard failed to create a port for communication with the Route Processor (ASR1000-RP). |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IOSXE_SIP_SPA-3-FAST_NOTIFY_ERROR : Failed to send fast notification to [chars] for [chars] [chars]. | |
---|---|
Explanation | The SPA driver failed to deliver a fast notification. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SIP_SPA-6-LOGGERMSGTOOBIG : Logger message length ([int] bytes) exceeds the maximum allowed size | |
---|---|
Explanation | The carrier card attempted to send a large message to the Route Processor |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SIP_SPA-3-FRR_CFG_FAIL : Failed to configure fast reroute on [chars]: [chars]. | |
---|---|
Explanation | The SPA driver failed to configure fast rerouting on an interface. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SIP_SPA-3-APS_CFG_FAIL : Failed to configure APS on [chars]: [chars]. | |
---|---|
Explanation | The SPA driver failed to configure APS on an interface. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SIP_SPA-3-APS_PGP_FAIL : APS PGP Message send failed toslot/tobay [dec]: [dec]. | |
---|---|
Explanation | APS PGP between working and protect has failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SIP_SPA-3-MDR_BACKUP_FAIL : Minimal Disruptive Restart backup failed for slot [int], bay [int]; reason ([chars]) | |
---|---|
Explanation | The SPA driver could not backup data required for Minimal Disruptive Restart process. The Minimal Disruptive Restart process for the SPA may be terminated as a consequence. |
Recommended Action | The Minimal Disruptive Restart backup is stored in RP harddisk or Bootflash. If sufficient space is available on these devices, copy the error message exactly as it appears, and report it to your technical support representative. |
%IOSXE_SIP_SPA-3-MDR_BACKUP_OPEN_FAIL : Failed to open Minimal Disruptive Restart backup for slot [int], bay [int], type [dec]; reason ([chars]) |
|
---|---|
Explanation | The SPA driver could not open Minimal Disruptive Restart backup file. The Minimal Disruptive Restart process may be terminated as a consequence. |
Recommended Action | The Minimal Disruptive Restart backup is stored in RP harddisk or Bootflash. If sufficient space is available on these devices, copy the error message exactly as it appears, and report it to your technical support representative. |
%IOSXE_SIP_SPA-3-MDR_BACKUP_WRITE_FAIL : Failed to write [dec] bytes to Minimal Disruptive Restart backup[chars] for slot [int], bay [int], type [dec]; reason ([chars]) |
|
---|---|
Explanation | The SPA driver could not write to Minimal Disruptive Restart backup file. The Minimal Disruptive Restart process may be terminated as a consequence. |
Recommended Action | The Minimal Disruptive Restart backup is stored in RP harddisk or Bootflash. If sufficient space is available on these devices, copy the error message exactly as it appears, and report it to your technical support representative. |
%IOSXE_SIP_SPA-3-MDR_BACKUP_READ_FAIL : Failed to read [dec] from Minimal Disruptive Restart backup for slot [int], bay [int], type [dec]; reason ([chars]) |
|
---|---|
Explanation | The SPA driver could not read from Minimal Disruptive Restart backup file. The Minimal Disruptive Restart process may be terminated as a consequence. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SIP_SPA-3-MDR_CONFIG_REPLAY : Configuration replay failed during Minimal Disruptive Restart for slot [int], bay [int]; reason ([chars]) |
|
---|---|
Explanation | The SPA driver failed to process config replay during Minimal Disruptive Restart. The Minimal Disruptive Restart process may be terminated as a consequence. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SIP_SPA-3-SPA_ETHER_SUSPEND_ERROR : SPA ETHER process suspended too long; totally for [dec] milliseconds | |
---|---|
Explanation | The SPA ETHER process is not able to write to ezman as ezman is blocked for writes. Copy the error message exactly as it appears and report it to your technical support representative. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_SPA
%IOSXE_SPA-3-CREATION_FAILURE : slot=[dec] subslot=[dec], spa_type=[hex], lc_type=[hex]. | |
---|---|
Explanation | Failed to create a SPA object. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-SPA_CREATION_FAILURE : slot=[dec] subslot=[dec], PID=[chars] lc_type=[hex]. | |
---|---|
Explanation | Failed to create a SPA object. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-NULL_VFT : [chars] virtual function table is not initialized. spaType=[hex] | |
---|---|
Explanation | A required function table is not initialized |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-NULL_VFUNC : [chars] vector is not initialized. spaType=[hex] | |
---|---|
Explanation | A required function vector is not initialized |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-MEM_ALLOC_ERROR : [chars] | |
---|---|
Explanation | Memory allocation error. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-NULL_SPA_PTR : | |
---|---|
Explanation | Pointer to a SPA object is NULL. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-NULL_BAY_PTR : | |
---|---|
Explanation | Pointer to SPA bay is NULL. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-INVALID_SLOT_NUM : slot= [dec], max slot = [dec] | |
---|---|
Explanation | An invalid slot number is specified in one of the internal APIs. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-INVALID_SUBSLOT_NUM : subslot= [dec], max subslot = [dec] | |
---|---|
Explanation | An invalid subslot number is specified in one of the internal APIs. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-INVALID_DB_NUM : db = [dec], max db = [dec], db intf = [dec], max db intf = [dec] | |
---|---|
Explanation | An invalid daughter board number is specified in one of the internal APIs. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-INVALID_RP_SLOT_NUM : slot= [dec], max slot = [dec] | |
---|---|
Explanation | An invalid RP slot number is specified in one of the internal APIs. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-INVALID_CPU_NUM : cpu= [dec], max cpu = [dec] | |
---|---|
Explanation | An invalid CPU number is specified in one of the internal APIs. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-INVALID_SLOTUNIT_NUM : cardwide-port = [dec], max cardwide-port = [dec] | |
---|---|
Explanation | An invalid cardwide-port number is specified in one of the internal APIs. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-INVALID_INDX_RANGE : index1= [dec], index2= [dec], maxIndex= [dec] | |
---|---|
Explanation | An invalid index range is specified in one of the internal APIs. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-INVALID_IF_INDEX : index= [dec], spaType=[hex], slot [dec] subSlot [dec] slotunit [dec] vc [dec] | |
---|---|
Explanation | Index for the interface is not valid. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-INVALID_DATA_INSTANCE : interface type [chars], slot [dec] port [dec] vc [dec] : [chars] | |
---|---|
Explanation | Data required to support the interface is not available. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-POWER_CYCLE : [chars] occurred on Shared Port Adapter [int]/[int] | |
---|---|
Explanation | An error has occurred which will cause the Shared Port Adapter to be power cycled |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-DIAG_CONFIG : [chars] did not complete [dec]/[dec] | |
---|---|
Explanation | An error has occured during diagnostic test. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-UNSUPPORTED_DATA : Data conversion error ([chars], [hex]) | |
---|---|
Explanation | An internal software error has occured when converting the data specified in the message from one representation to another. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-IPC_FAILURE : IPC failure while [chars] | |
---|---|
Explanation | An error has occurred while prepareing or sending an IPC message. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-SENDCFGFAIL : Failed to send configuration for [chars] to carrier-card for subslot=[dec]/[dec] | |
---|---|
Explanation | Sending configuration failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-CREATE_TDLH_FAILURE : Failed to create SPA [dec]/[dec] handle | |
---|---|
Explanation | Failed to create message handle for SPA communication. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-DOMAIN_TDLH_FAILURE : [chars], rc = [dec] | |
---|---|
Explanation | Failed to bind message handle for SPA communication. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-SETUP_TDLH_FAILURE : Failed to set the alloc/free handler for SPA [dec]/[dec] handle | |
---|---|
Explanation | Failed to set the alloc/free handler for SPA communication. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-DISPATCH_INIT_TDLH_FAILURE : Failed to initialize dispatch path for SPA [dec]/[dec] handle | |
---|---|
Explanation | Failed to initialize dispatch path handle for SPA communication. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-INVALID_SPA_TDL_CCAPI_USAGE : | |
---|---|
Explanation | Incorrect usage of an internal API that should only be used on CC. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-6-TDLMSG_INCOMPATIBLE : Failed to copy message [chars] to buffer, not allowed for current domain. | |
---|---|
Explanation | Failure to marshal a message indicates an incompatibility with the intended recipient. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-CREATE_TDLMSG_FAILURE : Failed to create [chars] message for [chars]. | |
---|---|
Explanation | Failed to create/allocate necessary TDL message for SPA communication. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-INVALID_HANDLE : Failed to get a valid IPC handle for type [int], slot [dec], subslot [dec]. | |
---|---|
Explanation | The client handle was found to be NULL for the given type/slot/subslot. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-6-UPDOWN : Interface [chars], link down due to [chars] | |
---|---|
Explanation | Ethernet link is down due to remote/local fault. |
Recommended Action | Replace the faulty cable. |
%IOSXE_SPA-6-DUAL_RATE_CHANGE : [chars]: [chars] | |
---|---|
Explanation | Change in rate of the link. |
Recommended Action | No action is required. |
%IOSXE_SPA-3-SPA_SETUP_FAILURE : Failed to properly setup for SPA communication on slot [dec], subslot [dec]. | |
---|---|
Explanation | Discovery of the linux interface used to communicate with a SPA failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SPA-3-ABANDON_SPA_CONFIGURATION : Abandon configuration for subslot [dec]/[dec], the SPA type([dec]) is NOT match with SUP card. |
|
---|---|
Explanation | Abandon SPA configuration. |
Recommended Action | Please check the startup configuration, use no card command to override wrong card configuration and update card type. |
IOSXE_SYS_INFRA
%IOSXE_SYS_INFRA-6-BIPC_READ_ERR : connection read error from [chars], rc [dec], bring down IPC id [dec] for fd [dec] seq [dec] |
|
---|---|
Explanation | BIPC error during IPC read |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-6-BIPC_READBUF_ERR : process receive buffer error from [chars], rc [dec], bring down IPC | |
---|---|
Explanation | BIPC error during IPC read from buffer |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-6-BIPC_DISCONNECT : disconnect by application for [chars], bring down IPC | |
---|---|
Explanation | BIPC disconnect requested by an application |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-6-BIPC_WRITE_ERR : write bipc error for [chars], rc [dec], bring down IPC | |
---|---|
Explanation | BIPC error during IPC read |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-6-BIPC_CREATE : bipc connect succeeded for [chars], ipc_ctl_id [dec], ipc_fd [dec], seq [dec] | |
---|---|
Explanation | BIPC connect succeeded |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-3-BIPC_CREATE_FAIL : Failed to open IPC port ‘[chars]’ for service ‘[chars]’ with error [chars]. | |
---|---|
Explanation | BIPC connect failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-3-BIPC_DISCONNECT_FAIL : Failed to disconnect IPC port ‘[chars]’ for service ‘[chars]’ with error [chars]. | |
---|---|
Explanation | BIPC disconnect failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-4-BIPC_TX_Q_THRESHOLD : BIPC transmit queue threshold reached for the channel ‘[chars]’: ipc_ctl_id [dec] (ipc_fd [dec], seq_num [dec]), Tx Q size [dec] |
|
---|---|
Explanation | Large number of unsent IPC messages are queued in a BIPC send buffer |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-4-BIPC_RX_IN_APPL_THRESHOLD : Number of IPC messages held in the application reached the maximum channel threshold. IPC channel ‘[chars]’: ipc_ctl_id [dec] (ipc_fd [dec], seq_num [dec]), curr IPC msg hel in appl [dec] |
|
---|---|
Explanation | Application is holding large number of received IPC messages |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-3-EVLIB_EPOLL_ARGS : evGetEpollArgs returned fd [dec] | |
---|---|
Explanation | Evlib retuned a huge FD value that IOS can not handle. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-6-EOBC_ADDR_CACHE : EOBC ip-table cache: [chars] | |
---|---|
Explanation | Unable to setup internal address for eobc communication |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-3-EOBC_SOCK : Socket event for [chars] | |
---|---|
Explanation | An internal socket level event has returned an error which is indicated. This may have been the result of a bind, peek, receive or send operation with respect to the EOBC interface listed. |
Recommended Action | LOG_STD_SH_CMD_ACTION(show eobc, show platform software infrastructure bipc) |
%IOSXE_SYS_INFRA-3-EWRITE_EVENT_FD : Write to [chars] wakeup fd failed, errno [dec], current signal/wakeup cnt: [int]/[int] | |
---|---|
Explanation | Trigering a thread by writing to its wakeup fd failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-3-EREAD_EVENT_FD : [chars] read from wakeup fd failed, errno [dec] | |
---|---|
Explanation | A thread reading from its wakeup fd failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-3-EIOS_POLL : IOS thread poll on event lib and wakeup fds failed, errno [dec] | |
---|---|
Explanation | IOS thread poll on event lib and wakeup fds failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-3-EIOS_EVDISPATCH : IOS scheduler event dispatch failed, ev_ret [dec], errno [dec] | |
---|---|
Explanation | IOS scheduler event dispatch failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-3-EIOS_EVGETNEXT : IOS scheduler get next event failed, ev_ret [dec], errno [dec] | |
---|---|
Explanation | IOS scheduler get next event failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-3-EFP_EVDISPATCH : Fastpath thread event dispatch failed, ev_ret [dec], errno [dec] | |
---|---|
Explanation | fastpath thread event dispatch failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-3-EFP_EVGETNEXT : Fastpath thread get next event failed, ev_ret [dec], errno [dec] | |
---|---|
Explanation | Fastpath thread get next event failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-3-EFP_EPOLL_WAIT : Fastpath thread epoll wait failed, errno [dec] | |
---|---|
Explanation | Fastpath epoll wait failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-3-EFP_TOP_EPOLL_CTL_FAILED : Fastpath thread top level efd epoll [chars] failed, fd [dec], errno [dec] | |
---|---|
Explanation | Fastpath top level efd epoll_ctl operation failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-3-EFP_IPC_EPOLL_CTL_FAILED : Fastpath thread [chars] [chars] for IPC channel [chars] (ipc id [dec], ipc fd [dec], seqnum [dec]) failed, efd [dec], errno [dec] |
|
---|---|
Explanation | Fastpath epoll_ctl operation for an IPC channel failed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-3-EFP_IPC_EPOLL_NO_IPC_ENTRY : IPC entry not found for ipc fd [dec], seq [dec], events [hex] while processing [chars] from epoll fd [dec] |
|
---|---|
Explanation | Fastpath failed to find IPC entry after epoll_wait |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-6-FP_IPC_DISCONNECT : IPC channel disconnect for [chars], ipc_ctl_id [dec], fd [dec], seq_num [dec], loc [chars], err [dec] ([chars]) |
|
---|---|
Explanation | An IPC channel in fastpath is terminated |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-6-IOS_IPC_CTL_DESTROY : IPC control blk destroy: name [chars], ipc_ctl_id [dec], refcout [dec], need_free [dec] |
|
---|---|
Explanation | An IPC control block is requested to be destroyed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-6-IOS_FREE_IPC_CTL : IPC control blk free: name [chars], ipc_ctl_id [dec], refcount [dec] | |
---|---|
Explanation | An IPC control block is freed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_SYS_INFRA-4-BIPC_CLEAR_CONN : IPC channel (fd [dec], seq_num [dec]) for service ‘[chars]’ cleared by user | |
---|---|
Explanation | BIPC disconnect requested by an user with clear command |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_THROUGHPUT
%IOSXE_THROUGHPUT-3-INVALID_CONFIG : No valid license found for the configured throughput level: [chars] kbps | |
---|---|
Explanation | Users has the boot up throughput set to non-default level without having the valid license. |
Recommended Action | Install valid throughput license |
%IOSXE_THROUGHPUT-3-EULA_NOT_ACCEPTED : The EULA has to be accepted prior to throughput configuration. | |
---|---|
Explanation | Users need to accept EULA to activate the license |
Recommended Action | Accept EULA for throughput license |
%IOSXE_THROUGHPUT-3-CONF_FAILED : Configuration failed. Installed license does not support the throughput level. Please install the valid license |
|
---|---|
Explanation | An error occurred when the throughput configuration was attempted. |
Recommended Action |
%IOSXE_THROUGHPUT-3-INVALID_LEVEL : An invalid throughput level: [chars] kbps was selected. | |
---|---|
Explanation | The configured throughput level is unknown |
Recommended Action |
%IOSXE_THROUGHPUT-6-LEVEL : Throughput level has been set to [dec]00000 kbps | |
---|---|
Explanation | Throughput level has been set to a number |
Recommended Action |
%IOSXE_THROUGHPUT-3-SETUP_FAILED : Throughput level setup failed. Boot up will be at the default throughput | |
---|---|
Explanation | An error occurred when licensing tried to setup the througput |
Recommended Action |
IOSXE_TIMESTAMP_ENGINE
%IOSXE_TIMESTAMP_ENGINE-4-ERROR : NULL | |
---|---|
Explanation | An unexpected condition has occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_TIMESTAMP_ENGINE-3-TSU_ERR : An unexpected condition has occurred at module ([chars]) | |
---|---|
Explanation | An unexpected condition has occurred at the Interface Module TSU. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_UPGRADE_ROMMON through IPA
-
IOSXE_UPGRADE_ROMMON
-
IOSXE_USB
-
IOSXE_UTD
-
IOSXE_VMAN
-
IOSXE_WCCP
-
IOSXE_WD
-
IOS_LICENSE_IMAGE_APPLICATION
-
IOXN_APP
-
IP
-
IPA
IOSXE_UPGRADE_ROMMON
%IOSXE_UPGRADE_ROMMON-0-ROMMON_UPGRADE_FAIL : ROMMON upgrade failed: partition [chars] | |
---|---|
Explanation | An attempt to upgrade the ROMmon failed. |
Recommended Action | Check the system messages to see if any messages appeared that might indicate the source of the ROMmon problem. If you do not find any additional information indicating a correctable problem, collect all output on the screen, in particular the console port output after the upgrade rom-monitor command was entered and the output of show rom-monitor, and provide the collected information to a Cisco technical support representative. |
%IOSXE_UPGRADE_ROMMON-0-ROMMON_LOADTEST_FAIL : ROMMON FIPS_140-3 Load test *FAILED*: file [chars] | |
---|---|
Explanation | FIPS 140-3 Related Load test failed for the ROMmon. |
Recommended Action | Check the system messages to see if any messages appeared that might indicate the source of the ROMmon Load test problem. If you do not find any additional information indicating a correctable problem, collect all output on the screen, in particular the console port output after the upgrade rom-monitor command was entered and the output of show rom-monitor, and provide the collected information to a Cisco technical support representative. |
IOSXE_USB
%IOSXE_USB-3-ESHOW_USB : Internal Error locating database for USB Devices. | |
---|---|
Explanation | The mcp_usb_devices is incorrect and needs to be changed |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_UTD
%IOSXE_UTD-3-ALLOC : Failed to allocate message | |
---|---|
Explanation | When attempting to program the dataplane there was not enough memory to allocate the message. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_UTD-3-MESSAGE : Failed to send message | |
---|---|
Explanation | When the message was being prepared for sending to the data plane, there was an error. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_UTD-4-VERSION_INCOMPATIBILITY : UTD package version [chars] does not match recommended UTD package version [chars] | |
---|---|
Explanation | The UTD package version does not match the recommended UTD package version embedded in this IOS-XE version. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_UTD-2-VERSION_UNSUPPORTED : UTD package version [chars] is not supported, recommended version is [chars] | |
---|---|
Explanation | The UTD package version does not match the required UTD version embedded in this IOS-XE version. This is an unsupported configuration and may behave unexpectedly. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_UTD-4-SIG_UPDATE_CFG : UTD signature updates have been configured — A brief service interruption at the time of update is expected |
|
---|---|
Explanation | The UTD service will be restarted if a new signature package is found. During this time, if fail-close has been configured (recommended), traffic that would be inspected by UTD will be dropped. Otherwise (default), traffic that would be inspected by UTD will be allowed to pass uninspected. To minimize this service interruption, it is recommended to schedule this operation outside of normal business hours. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_UTD-4-SIG_UPDATE_EXEC : UTD signature update has been executed — A brief service interruption is expected | |
---|---|
Explanation | The UTD service will be restarted if a new signature package is found. During this time, if fail-close has been configured (recommended), traffic that would be inspected by UTD will be dropped. Otherwise (default), traffic that would be inspected by UTD will be allowed to pass uninspected. To minimize this service interruption, it is recommended to execute this operation outside of normal business hours. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_UTD-4-MT_CONFIG_DOWNLOAD : UTD MT configuration download has [chars] | |
---|---|
Explanation | In UTD multitenancy mode, the configuration download to the container can take a while. Please be patient. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_UTD-4-MT_CONTAINER_MESSAGE_TIMEOUT : UTD message sent to the container has timed out | |
---|---|
Explanation | The UTD message sent to the container has timed out. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_UTD-4-MT_CONTAINER_MESSAGE_NAK : Container responded to UTD message with an error: [dec] | |
---|---|
Explanation | The container rejected the UTD message |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_UTD-4-MT_CONTAINER_SESSION_TIMEOUT : UTD container download has timed out | |
---|---|
Explanation | The container did not respond with an up/down status before the session timed out. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_UTD-4-MT_CONTAINER_STATUS_DOWN : UTD poll: container status is DOWN | |
---|---|
Explanation | The container sent a down status to the poll message |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_VMAN
%IOSXE_VMAN-3-MSGINITFAIL : Failed to initialize required Virt-manager resource: [chars] | |
---|---|
Explanation | During the initialization of the resources required by Virt-manager, a failure occurred. This has prevented virtual services from being activated. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_VMAN-3-MSGDISPATCH : Unable to dispatch received TDL message from Virt-manager | |
---|---|
Explanation | An unexpected condition has occurred while IOS was trying to dispatch a TDL message received from Virt-manager. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_VMAN-3-RSPMSGHDLR : Failed to deliver response message: [chars] | |
---|---|
Explanation | An unexpected condition has occurred while IOS was trying to deliver a response message to a virtual service received from Virt-manager. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_WCCP
%IOSXE_WCCP-4-NOINPUT : NULL input, [chars] | |
---|---|
Explanation | An unexpected condition has occurred which is due to the NULL value of the input parameter. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show ip wccp command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_WCCP-4-NOSVCGRP : [chars] Service Group ([dec], [dec], [int]) NOT exist | |
---|---|
Explanation | An unexpected condition has occurred which is due to the absence of the service group structure. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show ip wccp command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_WCCP-4-NOACL : Access list is null | |
---|---|
Explanation | An unexpected condition has occurred which is due to the absence of an access list structure. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show ip access-lists command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_WCCP-4-ACELIMIT : Too many ACEs in MASK ACL, please switch to Hash mode | |
---|---|
Explanation | Mask merged ACL generate too many ACEs. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show ip access-lists command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_WCCP-4-BADACE : Access list contains invalid ace | |
---|---|
Explanation | An unexpected condition has occurred which is due to an invalid statement in the access list structure. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show ip access-lists command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_WCCP-4-NOINTF : No [chars] interface info for Service Group ([dec], [dec], [int]) | |
---|---|
Explanation | An unexpected condition has occurred which is due to the absence of MCP WCCP interface info for the specific service group. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show platform software wccp command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_WCCP-4-UNKNOWNDIR : Unknown [chars] interface direction [hex] for Service Group ([dec], [dec], [int]) | |
---|---|
Explanation | An unexpected condition has occurred which is due to the unknown direction has been applied to the interface for the service group. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show platform software wccp command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_WCCP-4-NOSTATS : WCCP [chars] message error | |
---|---|
Explanation | An unexpected condition has occurred which is due to the error in receiving WCCP stats update message. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show platform software wccp <id> counters command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_WCCP-4-NOSTATSSVC : Service Group ([dec], [dec], [int]) not exist for the stats message | |
---|---|
Explanation | An unexpected condition has occurred which can’t find the service group for the service group stats message. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show platform software wccp command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOSXE_WCCP-4-NOSTATSINTF : Interface handle [int] not exsit for the stats message | |
---|---|
Explanation | An unexpected condition has occurred which can’t find the interface handle for the interface stats message. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show platform software wccp <id> int counters command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
IOSXE_WD
%IOSXE_WD-2-HEARTBEAT_FAIL : Heartbeat is not emitted. Heartbeat count:[dec] | |
---|---|
Explanation | Failure in IOS to generate a heartbeat is an abnormal condition |
Recommended Action | This message may be related to an abnormal configuration and system load, or transient high processing demand. When reporting this message, copy the message text exactly as it appears, include the stack trace and report to your technical support representative |
%IOSXE_WD-2-HOG_DETECT_FAIL : CPUHOG detection failed to start. | |
---|---|
Explanation | Failure in setting up CPUHOG detection mechanism is an abnormal condition |
Recommended Action | This message may be related to an abnormal configuration and system load, or transient high processing demand. When reporting this message, copy the message text exactly as it appears, include the stack trace and report to your technical support representative |
IOS_LICENSE_IMAGE_APPLICATION
%IOS_LICENSE_IMAGE_APPLICATION-3-FAILED : [chars] | |
---|---|
Explanation | The ios licensing subsystem failed to create a process/watched boolean etc to watch request from the remote show subsys license commands |
Recommended Action | please capture the error msg and forward it to the appropriate licensing component |
%IOS_LICENSE_IMAGE_APPLICATION-3-UNKNOWN_EVENT : [chars] | |
---|---|
Explanation | The ios image licensing subsystem received an event which it does not understand or recognizes |
Recommended Action | please capture the error msg and forward it to the appropriate licensing component |
%IOS_LICENSE_IMAGE_APPLICATION-3-UNKNOWN_VERSION : [chars] | |
---|---|
Explanation | |
Recommended Action |
%IOS_LICENSE_IMAGE_APPLICATION-6-NO_LICENSE : No valid license available: [chars] = [chars]; [chars] = [dec]; [chars] = [chars]:[chars] | |
---|---|
Explanation | The ios image licensing subsystem received an event for an unknown version of a feature There is no valid license available on the box and we are running on a default feature |
Recommended Action | please capture the error msg and forward it to the appropriate licensing component please purchase a license to activate required features |
%IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL : Module name = [chars] Next reboot level = [chars] and License = [chars] | |
---|---|
Explanation | This is an informational message to display the change in the next reboot license level |
Recommended Action | This is an informational message, no action is required |
%IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL_CONFIG : Please issue ‘license boot’ config command to make extension license ([chars]) available for use. |
|
---|---|
Explanation | This is an informational message to info user that to make extension license available to support image level, licensing image level needs to be configured |
Recommended Action | This is an informational message, no action is required |
%IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_CONFIG : EULA must be accepted for license level = [chars] | |
---|---|
Explanation | This is an informational message to inform user that the user needs to reissue the command from an interactive terminal |
Recommended Action | This is an informational message, no action is required |
IOXN_APP
%IOXN_APP-3-INITFAIL : Failed to create chasfs property ioxman (rc =[chars]) or caf (rc = [chars]) is not up | |
---|---|
Explanation | An unexpected condition resulted into failure to start an application. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOXN_APP-3-CLEANUPFAIL : Failed to create chasfs property to indicate cleanup of previous app installation (rc = [chars]) | |
---|---|
Explanation | An unexpected condition resulted in failure to setup the start of an application. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOXN_APP-3-GSFAIL : [chars] [int] | |
---|---|
Explanation | An unexpected condition resulted into failure to start an application. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOXN_APP-3-CFGFAIL : [chars] [chars] | |
---|---|
Explanation | An unexpected condition resulted into failure to apply auto config |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOXN_APP-3-PREVOPFAIL : Overriding previous operation ([chars] iox) that is taking longer than [int] secs to complete | |
---|---|
Explanation | An unexpected condition resulted in failure to apply iox config |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOXN_APP-3-MSGFAIL : Message dispatch failure ([chars]). | |
---|---|
Explanation | Message could not be dispatched to an application. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOXN_APP-6-STARTUP_CONFIG_INFO : [chars] | |
---|---|
Explanation | Informational logs for startup config injection. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOXN_APP-6-STARTUP_CONFIG_CHASSIS_INFO : [chars] [dec]/[chars]/[dec]/[dec] | |
---|---|
Explanation | Chassis information at startup config injection. |
Recommended Action | No action is required. |
%IOXN_APP-3-STARTUP_CONFIG_FAIL : [chars] [chars] | |
---|---|
Explanation | Error while creating startup config |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOXN_APP-3-IPCINITFAIL : [chars] | |
---|---|
Explanation | A critical IPC initialization error occured |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IOXN_APP-6-SLOT_NOTIFICATION : [chars] [dec] | |
---|---|
Explanation | Slot addition or removal information |
Recommended Action | No action is required. |
IP
%IP-4-CLASS : Bad IP address and mask [IP_address]%m in class_resolve() | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IP-4-DUPADDR : Duplicate address [IP_address] on [chars], sourced by [enet] | |
---|---|
Explanation | Another system is using your IP address. |
Recommended Action | Change the IP address of one of the two systems. |
%IP-4-ZERO_ADDR : Zero MAC address for [IP_address] in ARP cache | |
---|---|
Explanation | An entry in the ARP cache have a NULL MAC address |
Recommended Action | If this message recurs, call your technical support representative for assistance. |
%IP-3-DESTHOST : src=[IP_address], dst=[IP_address], NULL desthost | |
---|---|
Explanation | An internal software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IP-3-BADIPALIGN : Invalid alignment in packet for IP. [chars]=[hex] | |
---|---|
Explanation | The packet data structure is misaligned. This condition may result in a small amount of overhead in processing IP traffic. |
Recommended Action | Enter a show hardware command and report the output, along with this error message, to your technical support representative. |
%IP-3-BADSROUTE : Improper source route. Length [dec] Ptr [dec] | |
---|---|
Explanation | A hardware or software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IP-6-PHYBCASTDROP : Physical broadcast packet detected and dropped, src=[IP_address], dst=[IP_address] | |
---|---|
Explanation | Physical broadcast packet was dropped. |
Recommended Action | No action is required. |
%IP-6-L2MCASTDROP : Layer 2 Multicast packet detected and dropped, src=[IP_address], dst=[IP_address] | |
---|---|
Explanation | Layer 2 Multicast packet with Layer3 Unicast Destination was dropped. |
Recommended Action | No action is required. |
%IP-3-LOOPPAK : Looping packet detected and dropped — src=[IP_address], dst=[IP_address], hl=[int], tl=[int], prot=[int], sport=[int], dport=[int] in=[chars], nexthop=[IP_address], out=[chars]options=[chars] |
|
---|---|
Explanation | A software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IP-5-WEBINST_START : Attempting web install from host [IP_address] | |
---|---|
Explanation | A hardware or software error occurred. |
Recommended Action | Copy the error message exactly as it appears, and report it to your technical support representative. |
%IP-5-WEBINST_KILL : Terminating DNS process | |
---|---|
Explanation | A hardware or software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IP-5-WEBINST_COMP : Selected IP address [IP_address] | |
---|---|
Explanation | A hardware or software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IP-5-WEBINST_RESP : Sending DNS response to [IP_address] (request was for [IP_address]) | |
---|---|
Explanation | A hardware or software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IP-3-CNTRFULL : IP counter block is full (setting protocol [dec]) | |
---|---|
Explanation | An internal software error occured. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IP-5-TURBOACL : [chars] | |
---|---|
Explanation | Error occured in intialisation of TURBOACL. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show process command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IP-5-ACL : [chars] | |
---|---|
Explanation | Error occured in IP access checks. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IP-4-UNICASTRPF : IP unicast reverse-path check disabled on [chars] | |
---|---|
Explanation | The IP verify unicast reverse-path feature was disabled because CEF was disabled (either through configuration or due to an internal error. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IP-3-LOOPOUTIF : Output interface for packet has been changed for [dec] times and dropped — src=[IP_address], dst=[IP_address], hl=[int], tl=[int], prot=[int], in=[chars], nexthop=[IP_address], out=[chars] |
|
---|---|
Explanation | A software error occurred. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IP-3-MAXIRDP : Attempt to send IRDP to proxies exceeding configurable limit: [dec], interface: [chars], secondary = [dec], proxy = [dec] |
|
---|---|
Explanation | The sum of configured secondary addresses and configured proxy addresses exceeds the number of total addresses that the IRDP can support in its implementation. |
Recommended Action | Reduce the number of either the secondary IP addresses or proxy addresses configured for the interface. |
%IP-4-IPPOOLS : Detected a local pool and a DHCP pool with the same name: [chars] | |
---|---|
Explanation | A local pool and a DHCP pool have been configured with the same name. This may cause conflict during address allocations. |
Recommended Action | Change the name of one of the two pools |
%IP-3-ICMPRATELIMIT : [int]nreachables rate-limited within [int] milliseconds on [chars]. [int] log messages suppressed since last log message displayed on [chars] |
|
---|---|
Explanation | An excessive number of packets are triggering log messages on this interface |
Recommended Action | change the log threshold with the icmp rate-limit command or find the source of the packets and block the packets from this router |
%IP-3-ICMPRATELIMITDF : [int] DF unreachables rate-limited within [int] milliseconds on [chars]. [int] DF log messages suppressed since last log message displayed on [chars] |
|
---|---|
Explanation | An excessive number of packets are triggering log messages on this interface |
Recommended Action | change the log threshold with the icmp rate-limit command or find the source of the packets and block the packets from this router |
%IP-3-NOOUTINTF : Output interface not available. source address: [IP_address], destination address: [IP_address], routing type: [int] |
|
---|---|
Explanation | The output interface for this packet is not set |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IP-3-NONALIAS : non-alias address [IP_address] in table [chars] found in IP alias list | |
---|---|
Explanation | The IP alias list holds IP aliases only but non-alias entries are found. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IP-3-IPTOPOID : Topology ID [hex] is invalid, can’t get the base topology ID. | |
---|---|
Explanation | An internal software error occurred |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IP-3-SBINIT : Error initializing [chars] subblock data structure. [chars] | |
---|---|
Explanation | Initialization of the specified subblock data structure could not be accomplished. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information. |
IPA
%IPA-3-PORTCONN : bay [[int]] failed to establish [chars] connection ([hex]) | |
---|---|
Explanation | An attempt to establish the console or debugger connection with the channel port adapter failed. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IPA-3-PORTIOKILL : Port IO [chars] process terminating. | |
---|---|
Explanation | Unexpected termination of a port io process. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IPA-3-NEVER : bay [[chars]] mailbox response timed out after ([int] + [int]) usecs, mbx=[hex] | |
---|---|
Explanation | A mailbox command sent from driver to the channel port adapter never completed within the expected time limit. As a result of this error, the channel port adapter driver will reset the port adapter and reload microcode to it. |
Recommended Action | The reset and reload rectified the problem. If that did not occur, then try the microcode reload operation again. <Body><par>If the error still occurs, record the output from the following commands: <Bullet><par>show tech <Bullet><par>dir slot0: <Bullet><par>dir slot1: <Bullet><par>show log <Body><par>Provide this information to your technical support representative. |
%IPA-3-UKNMBXCMD : [chars]: unknown mailbox command: [hex] [hex] [hex] [hex] | |
---|---|
Explanation | The channel port adapter sent a mailbox command that the driver did not expect. This may occur if there is a version mismatch between the system image and the microcode. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
%IPA-3-INVMBXCMD : [chars]: invalid mailbox command: [hex] | |
---|---|
Explanation | A subsytem attempted to register a mailbox command that is out of range. |
Recommended Action | Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information. |
Stumped: gbic-invalid error, bad crc — anyone see this before?
so I’ve been successfully able to make a fiber etherchannel between my 3750G’s upon themselves, but I’m trying to connect the 3750G (Master) in a uplink to my HP Procurve 2910al and I’m getting a bad crc error:
00:10:02: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port 65564 has bad crc
00:10:02: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/28, putting Gi1/0/28 in err-disable state
00:10:04: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/28, changed state to down
.
here is the config on the 3750G — it’s a factory reset, basic config only. anyone see something I’m missing? — at the bottom will be the HP Procurve. Only thing I can think of is maybe the 3750G needs a firmware update. I’ve tried a Netgear, Dell, and HP Gbic stick and they all give the same crc. Even brand-new Netgeat carrot sticks; i’m perplexed.
Switch#
Switch#show ver
Cisco IOS Software, C3750 Software (C3750-IPBASEK9-M), Version 12.2(25)SEB1, RELEASE SOFTWARE (fc1)
Copyright (c) 1986-2005 by Cisco Systems, Inc.
Compiled Sat 30-Apr-05 02:33 by yenanh
ROM: Bootstrap program is C3750 boot loader
BOOTLDR: C3750 Boot Loader (C3750-HBOOT-M) Version 12.1(14r)EA1a, RELEASE SOFTWARE (fc1)
Switch uptime is 8 hours, 12 minutes
System returned to ROM by power-on
System image file is «flash:c3750-ipbasek9-mz.122-25.SEB1/c3750-ipbasek9-mz.122-25.SEB1.bin»
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
Switch#
Switch#
Switch#
Switch#
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>enable
Switch#
Switch#
Switch#
Switch#
Switch#
Switch#
Switch#
Switch#show config
Using 1891 out of 524288 bytes
!
version 12.2
no service pad
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
!
hostname Switch
!
!
no aaa new-model
switch 1 provision ws-c3750g-24ts
ip subnet-zero
ip routing
!
!
!
!
!
!
no file verify auto
spanning-tree mode pvst
spanning-tree extend system-id
!
vlan internal allocation policy ascending
!
interface Port-channel1
switchport trunk encapsulation dot1q
switchport mode trunk
!
interface GigabitEthernet1/0/1
!
interface GigabitEthernet1/0/2
!
interface GigabitEthernet1/0/3
!
interface GigabitEthernet1/0/4
!
interface GigabitEthernet1/0/5
!
interface GigabitEthernet1/0/6
!
interface GigabitEthernet1/0/7
!
interface GigabitEthernet1/0/8
!
interface GigabitEthernet1/0/9
!
interface GigabitEthernet1/0/10
!
interface GigabitEthernet1/0/11
!
interface GigabitEthernet1/0/12
!
interface GigabitEthernet1/0/13
!
interface GigabitEthernet1/0/14
!
interface GigabitEthernet1/0/15
!
interface GigabitEthernet1/0/16
!
interface GigabitEthernet1/0/17
!
interface GigabitEthernet1/0/18
!
interface GigabitEthernet1/0/19
!
interface GigabitEthernet1/0/20
switchport mode access
!
interface GigabitEthernet1/0/21
switchport mode access
!
interface GigabitEthernet1/0/22
switchport mode access
!
interface GigabitEthernet1/0/23
switchport mode access
!
interface GigabitEthernet1/0/24
switchport mode access
!
interface GigabitEthernet1/0/25
!
interface GigabitEthernet1/0/26
!
interface GigabitEthernet1/0/27
!
interface GigabitEthernet1/0/28
switchport trunk encapsulation dot1q
switchport mode trunk
channel-group 1 mode active
!
interface Vlan1
description ‘Primary Vlan’
no ip address
!
interface Vlan100
ip address 192.168.225.31 255.255.255.192
ip helper-address 192.168.225.1
!
ip classless
ip http server
ip http secure-server
!
!
control-plane
!
!
line con 0
line vty 0 4
no login
line vty 5 15
no login
!
!
end
Switch#show inter giga1/0/28
GigabitEthernet1/0/28 is down, line protocol is down (err-disabled)
Hardware is Gigabit Ethernet, address is 0013.c444.809c (bia 0013.c444.809c)
MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive not set
Auto-duplex, Auto-speed, link type is auto, media type is unknown
input flow-control is off, output flow-control is unsupported
ARP type: ARPA, ARP Timeout 04:00:00
Last input never, output never, output hang never
Last clearing of «show interface» counters never
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: fifo
Output queue: 0/40 (size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts (0 multicast)
0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 watchdog, 0 multicast, 0 pause input
0 input packets with dribble condition detected
0 packets output, 0 bytes, 0 underruns
—More—
Switch#
Switch#config t
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#inter giga1/0/28
Switch(config-if)#no shut
Switch(config-if)#exit
Switch(config)#exit
Switch#show inter giga1/0/28
08:18:43: %SYS-5-CONFIG_I: Configured from console by console
GigabitEthernet1/0/28 is down, line protocol is down (err-disabled)
Hardware is Gigabit Ethernet, address is 0013.c444.809c (bia 0013.c444.809c)
MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive not set
Auto-duplex, Auto-speed, link type is auto, media type is unknown
input flow-control is off, output flow-control is unsupported
ARP type: ARPA, ARP Timeout 04:00:00
Last input never, output never, output hang never
Last clearing of «show interface» counters never
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: fifo
Output queue: 0/40 (size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts (0 multicast)
0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 watchdog, 0 multicast, 0 pause input
0 input packets with dribble condition detected
0 packets output, 0 bytes, 0 underruns
—More—
@
@
File «flash:c3750-ipbasek9-mz.122-25.SEB1/c3750-ipbasek9-mz.122-25.SEB1.bin» unc ompressed and installed, entry point: 0x3000
executing.
Restricted Rights Legend
Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software — Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.
cisco Systems, Inc.
170 West Tasman Drive
San Jose, California 95134-1706
Cisco IOS Software, C3750 Software (C3750-IPBASEK9-M), Version 12.2(25)SEB1, REL EASE SOFTWARE (fc1)
Copyright (c) 1986-2005 by Cisco Systems, Inc.
Compiled Sat 30-Apr-05 02:33 by yenanh
Image text-base: 0x00003000, data-base: 0x00DB5330
flashfs[1]: 358 files, 5 directories
flashfs[1]: 0 orphaned files, 0 orphaned directories
flashfs[1]: Total bytes: 15998976
flashfs[1]: Bytes used: 7683072
flashfs[1]: Bytes available: 8315904
flashfs[1]: flashfs fsck took 4 seconds.
flashfs[1]: Initialization complete. done Initializing flashfs.
POST: CPU MIC register Tests : Begin
POST: CPU MIC register Tests : End, Status Passed
POST: PortASIC Memory Tests : Begin
POST: PortASIC Memory Tests : End, Status Passed
POST: CPU MIC PortASIC interface Loopback Tests : Begin
POST: CPU MIC PortASIC interface Loopback Tests : End, Status Passed
POST: PortASIC RingLoopback Tests : Begin
POST: PortASIC RingLoopback Tests : End, Status Passed
Waiting for Stack Master Election (around 30 seconds).
POST: PortASIC CAM Subsystem Tests : Begin
POST: PortASIC CAM Subsystem Tests : End, Status Passed
POST: No Cable found on stack port 1
POST: No Cable found on stack port 2
POST: PortASIC Stack Port Loopback Tests : Begin
POST: PortASIC Stack Port Loopback Tests : End, Status Passed
POST: PortASIC Port Loopback Tests : Begin
POST: PortASIC Port Loopback Tests : End, Status Passed
Election Complete
Switch 1 booting as Master
Waiting for Port download. Complete
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
Export Compliance Product Report Application
If you require further assistance please contact us by sending email to
[email protected] .
cisco WS-C3750G-24TS (PowerPC405) processor (revision H0) with 118784K/12280K by tes of memory.
Processor board ID CAT0916Y04G
Last reset from power-on
1 Virtual Ethernet interface
28 Gigabit Ethernet interfaces
The password-recovery mechanism is enabled.
512K bytes of flash-simulated non-volatile configuration memory.
Base ethernet MAC Address : 00:13:C4:44:80:80
Motherboard assembly number : 73-7058-12
Power supply part number : 341-0045-01
Motherboard serial number : CAT091605VP
Power supply serial number : LIT091003WE
Model revision number : H0
Motherboard revision number : A0
Model number : WS-C3750G-24TS-S
System serial number : CAT0916Y04G
Hardware Board Revision Number : 0x09
Switch Ports Model SW Version SW Image * 1 28 WS-C3750G-24TS 12.2(25)SEB1 C3750-IPBASEK9-M
Failed to generate persistent self-signed certificate.
Secure server will use temporary self-signed certificate.
Press RETURN to get started!
00:01:25: %STACKMGR-6-SWITCH_ADDED: Switch 1 has been ADDED to the stack
00:01:26: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state t o down
00:01:28: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
00:01:30: %SYS-5-CONFIG_I: Configured from memory by console
00:01:30: %STACKMGR-6-SWITCH_READY: Switch 1 is READY
00:01:30: %STACKMGR-6-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to st ate DOWN
00:01:30: %STACKMGR-6-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to st ate DOWN
00:01:30: %STACKMGR-6-MASTER_READY: Master Switch 1 is READY
00:01:30: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port 65564 has bad c rc
00:01:30: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/28, putting Gi 1/0/28 in err-disable state
00:01:30: %SYS-5-RESTART: System restarted —
Cisco IOS Software, C3750 Software (C3750-IPBASEK9-M), Version 12.2(25)SEB1, REL EASE SOFTWARE (fc1)
Copyright (c) 1986-2005 by Cisco Systems, Inc.
Compiled Sat 30-Apr-05 02:33 by yenanh
Switch>
Switch>enable
Switch#config t
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#inter giga1/0/28
Switch(config-if)#keep
Switch(config-if)#keepalive 10
Switch(config-if)#exit
Switch(config)#exit
Switch#wr
00:09:17: %SYS-5-CONFIG_I: Configured from console by consoleme
Translating «wrme». domain server (255.255.255.255)
% Unknown command or computer name, or unable to find computer address
Switch#
Switch#
Switch#copy
Switch#copy ru
Switch#copy running-config st
Switch#copy running-config startup-config
Destination filename [startup-config]?
Building configuration.
[OK]
Switch#
Switch#
Switch#
Switch#config t
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#inter giga1/0/28
Switch(config-if)#shut
Switch(config-if)#no
00:09:58: %LINK-5-CHANGED: Interface GigabitEthernet1/0/28, changed state to administratively downshut
Switch(config-if)#
00:10:02: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port 65564 has bad crc
00:10:02: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/28, putting Gi1/0/28 in err-disable state
00:10:04: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/28, changed state to down
Switch>$col on Interface Vlan1, changed state t o down
00:01:26: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state t^ o down
% Invalid input detected at ‘^’ marker.
Switch>$SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
00:01:28: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
^
% Invalid input detected at ‘^’ marker.
Switch>00:01:30: %SYS-5-CONFIG_I: Configured from memory by console
^
% Invalid input detected at ‘^’ marker.
Switch>00:01:30: %STACKMGR-6-SWITCH_READY: Switch 1 is READY
^
% Invalid input detected at ‘^’ marker.
Switch>$Stack Port 1 Switch 1 has changed to st ate DOWN
00:01:30: %STACKMGR-6-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to st^ ate DOWN
% Invalid input detected at ‘^’ marker.
Switch>$Stack Port 2 Switch 1 has changed to st ate DOWN
00:01:30: %STACKMGR-6-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to st^ ate DOWN
% Invalid input detected at ‘^’ marker.
Switch>00:01:30: %STACKMGR-6-MASTER_READY: Master Switch 1 is READY
^
% Invalid input detected at ‘^’ marker.
Switch>$CRC_ERROR: GBIC in port 65564 has bad c rc
00:01:30: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port 65564 has bad c^ rc
% Invalid input detected at ‘^’ marker.
Switch>$i1/0/28, putting Gi 1/0/28 in err-disable state
00:01:30: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/28, putting Gi^ 1/0/28 in err-disable state
% Invalid input detected at ‘^’ marker.
Switch>00:01:30: %SYS-5-RESTART: System restarted —
^
% Invalid input detected at ‘^’ marker.
Switch>$n 12.2(25)SEB1, REL EASE SOFTWARE (fc1)
Cisco IOS Software, C3750 Software (C3750-IPBASEK9-M), Version 12.2(25)SEB1, REL ^ EASE SOFTWARE (fc1)
% Invalid input detected at ‘^’ marker.
Switch>Copyright (c) 1986-2005 by Cisco Systems, Inc.
^
% Invalid input detected at ‘^’ marker.
Switch>Compiled Sat 30-Apr-05 02:33 by yenanh
^
% Invalid input detected at ‘^’ marker.
Switch>$abitEthernet1/0/23, changed state to up
00:01:33: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/23,^ changed state to up
% Invalid input detected at ‘^’ marker.
Switch>$LINK-3-UPDOWN: Interface GigabitEthernet1/0/23, changed state to up
00:01:34: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/23, changed state to up
^
% Invalid input detected at ‘^’ marker.
Switch>$col on Interface Vlan1, changed state t o up
00:02:03: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state t^ o up
% Invalid input detected at ‘^’ marker.
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>enable
Switch#config t
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#inter giga1/0/28
Switch(config-if)#keep
Switch(config-if)#keepalive 10
Switch(config-if)#exit
Switch(config)#exit
Switch#wr
00:09:17: %SYS-5-CONFIG_I: Configured from console by consoleme
Translating «wrme». domain server (255.255.255.255)
% Unknown command or computer name, or unable to find computer address
Switch#
Switch#
Switch#copy
Switch#copy ru
Switch#copy running-config st
Switch#copy running-config startup-config
Destination filename [startup-config]?
Building configuration.
[OK]
Switch#
Switch#
Switch#
Switch#config t
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#inter giga1/0/28
Switch(config-if)#shut
Switch(config-if)#no
00:09:58: %LINK-5-CHANGED: Interface GigabitEthernet1/0/28, changed state to administratively downshut
Switch(config-if)#
00:10:02: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port 65564 has bad crc
00:10:02: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/28, putting Gi1/0/28 in err-disable state
00:10:04: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/28, changed state to down
00:13:57: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port 65564 has bad crc
Switch(config-if)#
Switch(config-if)#
Switch(config-if)#
Switch(config-if)#
00:15:17: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port 65562 has bad crc
00:15:17: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/26, putting Gi1/0/26 in err-disable state
00:15:37: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port 65561 has bad crc
00:15:37: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/25, putting Gi1/0/25 in err-disable state
Switch con0 is now available
Press RETURN to get started.
00:24:20: %SYS-5-CONFIG_I: Configured from console by console
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>enable
Switch#show ip inter br
Interface IP-Address OK? Method Status Protocol
Vlan1 unassigned YES NVRAM up up
Vlan100 192.168.225.31 YES NVRAM up down
GigabitEthernet1/0/1 unassigned YES unset down down
GigabitEthernet1/0/2 unassigned YES unset down down
GigabitEthernet1/0/3 unassigned YES unset down down
GigabitEthernet1/0/4 unassigned YES unset down down
GigabitEthernet1/0/5 unassigned YES unset down down
GigabitEthernet1/0/6 unassigned YES unset down down
GigabitEthernet1/0/7 unassigned YES unset down down
GigabitEthernet1/0/8 unassigned YES unset down down
GigabitEthernet1/0/9 unassigned YES unset down down
GigabitEthernet1/0/10 unassigned YES unset down down
GigabitEthernet1/0/11 unassigned YES unset down down
GigabitEthernet1/0/12 unassigned YES unset down down
GigabitEthernet1/0/13 unassigned YES unset down down
GigabitEthernet1/0/14 unassigned YES unset down down
GigabitEthernet1/0/15 unassigned YES unset down down
GigabitEthernet1/0/16 unassigned YES unset down down
GigabitEthernet1/0/17 unassigned YES unset down down
GigabitEthernet1/0/18 unassigned YES unset down down
GigabitEthernet1/0/19 unassigned YES unset down down
GigabitEthernet1/0/20 unassigned YES unset down down
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset up up
GigabitEthernet1/0/24 unassigned YES unset down down
GigabitEthernet1/0/25 unassigned YES unset down down
GigabitEthernet1/0/26 unassigned YES unset down down
GigabitEthernet1/0/27 unassigned YES unset down down
GigabitEthernet1/0/28 unassigned YES unset down down
Port-channel1 unassigned YES unset down down
Switch#
Switch#
Switch#
Switch#
Switch#
Switch#
Switch#
ProCurve J9148A 2910al-48G-PoE Switch
Software revision W.14.49
Copyright (C) 1991-2010 Hewlett-Packard Co. All Rights Reserved.
RESTRICTED RIGHTS LEGEND
Use, duplication, or disclosure by the Government is subject to restrictions
as set forth in subdivision (b) (3) (ii) of the Rights in Technical Data and
Computer Software clause at 52.227-7013.
HEWLETT-PACKARD COMPANY, 3000 Hanover St., Palo Alto, CA 94303
We’d like to keep you up to date about:
* Software feature updates
* New product announcements
* Special events
Please register your products now at: www.ProCurve.com
Smith-MDF# show config
; J9148A Configuration Editor; Created on release #W.14.49
hostname «Smith-MDF»
module 1 type J9148A
interface 25
disable
exit
interface 46
disable
exit
interface 48
disable
exit
trunk 47 Trk2 LACP
ip default-gateway 192.168.225.1
ip routing
vlan 1
name «DATA-vlan»
untagged 25-26,44,48
no untagged 1-24,27-43,45-46,Trk2
no ip address
exit
vlan 2
name «smith-camera’s»
untagged 35-36,39-40
ip address 192.200.102.1 255.255.255.224
exit
vlan 4
name «disabled-ports»
untagged 46
no ip address
exit
vlan 15
name «Wireless»
untagged 30-34
ip helper-address 172.16.35.8
ip address 172.16.35.2 255.255.255.224
exit
vlan 5
name «dell switch»
untagged 37-38,45
ip helper-address 192.168.2.6
ip address 192.168.2.5 255.255.255.0
exit
vlan 100
name «Primary-Vlan»
untagged 1-24,27-29,41-43,Trk2
ip helper-address 192.168.225.1
ip address 192.168.225.15 255.255.255.192
exit
ip route 0.0.0.0 0.0.0.0 192.168.225.1
ip route 172.16.7.0 255.255.255.0 192.225.225.6
ip route 172.16.8.0 255.255.255.0 192.225.225.6
ip route 172.16.35.0 255.255.255.224 172.16.35.3
ip route 192.168.102.0 255.255.255.0 192.225.225.6
ip route 192.168.104.0 255.255.255.0 192.225.225.6
ip route 192.168.106.0 255.255.255.0 192.225.225.6
ip route 192.168.108.0 255.255.255.0 192.225.225.6
ip route 192.168.120.0 255.255.255.0 192.225.225.6
ip route 192.168.130.0 255.255.255.0 192.225.225.6
snmp-server community «public» unrestricted
spanning-tree
spanning-tree Trk2 priority 4
primary-vlan 100
management-vlan 100
no autorun
password manager
Smith-MDF#
Smith-MDF#
Smith-MDF#
Источник
Hi We are having an issue with a 3750X. 7 Ports are down showing the same error:
*Mar 1 02:20:36.791: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/14
*Mar 1 02:20:36.791: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/14
*Mar 1 02:20:36.800: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/14 has bad crc
We have done shutdown and no shutdown but to no avail. Also we have tested ports with known working SFP’s and still get the same errors.
Any help would be appreciated, Thanks: Here are the error logs:
This is after inserting each GBIC
=================================
SILSSWC-WTTSL2#
*Mar 1 02:20:36.791: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/14
*Mar 1 02:20:36.791: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/14
*Mar 1 02:20:36.800: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/14 has bad crc
SILSSWC-WTTSL2#
*Mar 1 02:20:41.892: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/15
*Mar 1 02:20:41.900: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/15 has bad crc
SILSSWC-WTTSL2#
*Mar 1 02:20:45.490: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/16
*Mar 1 02:20:45.499: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/16 has bad crc
SILSSWC-WTTSL2#
*Mar 1 02:20:49.064: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/17
*Mar 1 02:20:49.072: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/17 has bad crc
SILSSWC-WTTSL2#
*Mar 1 02:20:52.394: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/18
*Mar 1 02:20:52.403: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/18 has bad crc
SILSSWC-WTTSL2#
*Mar 1 02:20:55.221: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/19
*Mar 1 02:20:55.230: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/19 has bad crc
SILSSWC-WTTSL2#
*Mar 1 02:20:58.308: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/20
*Mar 1 02:20:58.317: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/20 has bad crc
SILSSWC-WTTSL2#
*Mar 1 02:21:36.602: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/0/3: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -13.5 dBm.
*Mar 1 02:21:37.550: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/0/6: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -13.5 dBm.
SILSSWC-WTTSL2#
*Mar 1 02:21:38.683: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/0/8: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -13.5 dBm.
*Mar 1 02:21:39.152: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/0/9: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -13.5 dBm.
*Mar 1 02:21:39.614: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/0/10: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -13.5 dBm.
SILSSWC-WTTSL2#
*Mar 1 02:21:40.151: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/0/11: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -13.5 dBm.
*Mar 1 02:21:40.520: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/0/12: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -13.5 dBm.
SILSSWC-WTTSL2#
Output of ‘show log’ after inserting GBICs in ports 14 through 20.
===================================================================
*Mar 1 02:18:42.379: %SYS-5-CONFIG_I: Configured from console by vty0 (100.0.0.199)
*Mar 1 02:19:11.303: %LINK-5-CHANGED: Interface GigabitEthernet1/0/20, changed state to administratively down
*Mar 1 02:19:18.350: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/20
*Mar 1 02:19:18.358: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/20 has bad crc
*Mar 1 02:19:18.358: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/20, putting Gi1/0/20 in err-disable state
*Mar 1 02:19:19.734: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/20, changed state to down
*Mar 1 02:19:30.161: %SYS-5-CONFIG_I: Configured from console by vty0 (100.0.0.199)
*Mar 1 02:20:36.791: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/14
*Mar 1 02:20:36.791: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/14
*Mar 1 02:20:36.800: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/14 has bad crc
*Mar 1 02:20:41.892: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/15
*Mar 1 02:20:41.900: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/15 has bad crc
*Mar 1 02:20:45.490: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/16
*Mar 1 02:20:45.499: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/16 has bad crc
*Mar 1 02:20:49.064: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/17
*Mar 1 02:20:49.072: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/17 has bad crc
*Mar 1 02:20:52.394: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/18
*Mar 1 02:20:52.403: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/18 has bad crc
*Mar 1 02:20:55.221: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/19
*Mar 1 02:20:55.230: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/19 has bad crc
*Mar 1 02:20:58.308: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/20
*Mar 1 02:20:58.317: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/20 has bad crc
Output of ‘show interface status’
=================================
See each of those ports shows unknown. Also just noticed port Gi1/0/5 showing the same error.
SILSSWC-WTTSL2#sh int status
Port Name Status Vlan Duplex Speed Type
Gi1/0/1 WTTSL2-MCA notconnect 2 auto auto 10/100/1000BaseTX SFP
Gi1/0/2 WTTSL2-MCB notconnect 2 auto auto 10/100/1000BaseTX SFP
Gi1/0/3 WTTSL2-DLA (When F notconnect 2 full 1000 1000BaseSX SFP
Gi1/0/4 WTTSL2-DLB notconnect 2 auto auto 10/100/1000BaseTX SFP
Gi1/0/5 WTTSL2-DP3A notconnect 2 full 1000 unknown
Gi1/0/6 WTTSL2-DP4A (When notconnect 2 full 1000 1000BaseSX SFP
Gi1/0/7 WTTSL2-NAS connected 2 a-full a-1000 10/100/1000BaseTX SFP
Gi1/0/8 notconnect 2 full 1000 1000BaseSX SFP
Gi1/0/9 notconnect 2 full 1000 1000BaseSX SFP
Gi1/0/10 notconnect 2 full 1000 1000BaseSX SFP
Gi1/0/11 notconnect 2 full 1000 1000BaseSX SFP
Gi1/0/12 notconnect 2 full 1000 1000BaseSX SFP
Gi1/0/13 WTTSL2-PSIM notconnect 3 auto auto 10/100/1000BaseTX SFP
Gi1/0/14 WTTSL2-OMNI1-Link1 err-disabled 3 full 1000 unknown
Gi1/0/15 WTTSL2-OMNI2-Link1 err-disabled 3 full 1000 unknown
Gi1/0/16 WTTSL2-TGRSRV err-disabled 3 full 1000 unknown
Gi1/0/17 WTTSL2-TGRCLNT (Wh err-disabled 3 full 1000 unknown
Gi1/0/18 err-disabled 3 full 1000 unknown
Gi1/0/19 err-disabled 3 full 1000 unknown
Gi1/0/20 err-disabled 3 full 1000 unknown
Gi1/0/21 connected 3 full 1000 1000BaseSX SFP
Gi1/0/22 notconnect 3 full 1000 1000BaseSX SFP
Gi1/0/23 notconnect 3 full 1000 1000BaseSX SFP
Gi1/0/24 WTTSL2-TIMESOURCE connected 66 a-full a-100 10/100/1000BaseTX SFP
Fa0 notconnect routed auto auto 10/100BaseTX
SILSSWC-WTTSL2#
Output when all ports are set to shutdown and then no shut.
===========================================================
SILSSWC-WTTSL2(config)#int range gi1/0/14 — 20
SILSSWC-WTTSL2(config-if-range)#shut
SILSSWC-WTTSL2(config-if-range)#
*Mar 1 02:26:39.045: %LINK-5-CHANGED: Interface GigabitEthernet1/0/14, changed state to administratively down
*Mar 1 02:26:39.045: %LINK-5-CHANGED: Interface GigabitEthernet1/0/15, changed state to administratively down
*Mar 1 02:26:39.053: %LINK-5-CHANGED: Interface GigabitEthernet1/0/16, changed state to administratively down
*Mar 1 02:26:39.053: %LINK-5-CHANGED: Interface GigabitEthernet1/0/17, changed state to administratively down
*Mar 1 02:26:39.062: %LINK-5-CHANGED: Interface GigabitEthernet1/0/18, changed state to administratively down
*Mar 1 02:26:39.062: %LINK-5-CHANGED: Interface GigabitEthernet1/0/19, changed state to administratively down
SILSSWC-WTTSL2(config-if-range)#
*Mar 1 02:26:39.070: %LINK-5-CHANGED: Interface GigabitEthernet1/0/20, changed state to administratively down
SILSSWC-WTTSL2(config-if-range)#no shut
SILSSWC-WTTSL2(config-if-range)#
*Mar 1 02:26:52.677: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/17
*Mar 1 02:26:52.685: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/17 has bad crc
*Mar 1 02:26:52.685: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/17, putting Gi1/0/17 in err-disable state
*Mar 1 02:26:52.727: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/15
*Mar 1 02:26:52.735: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/15 has bad crc
*Mar 1 02:26:52.735: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/15, putting Gi1/0/15 in err-disable state
*Mar 1 02:26:52.777: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/14
*Mar 1 02:26:52.777: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/14
*Mar 1 02:26:52.786: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/14 has bad crc
*Mar 1 02:26:52.786: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/14, putting Gi1/0/14 in err-disable state
*Mar 1 02:26:52.819: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/18
*Mar 1 02:26:52.828: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/18 has bad crc
*Mar 1 02:26:52.828: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/18, putting Gi1/0/18 in err-disable state
*Mar 1 02:26:52.861: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/20
*Mar 1 02:26:52.869: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/20 has bad crc
*Mar 1 02:26:52.869: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/20, putting Gi1/0/20 in err-disable state
*Mar 1 02:26:52.903: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/19
*Mar 1 02:26:52.911: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/19 has bad crc
SILSSWC-WTTSL2(config-if-range)#
*Mar 1 02:26:52.911: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/19, putting Gi1/0/19 in err-disable state
*Mar 1 02:26:53.020: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/16
*Mar 1 02:26:53.029: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/16 has bad crc
*Mar 1 02:26:53.029: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/16, putting Gi1/0/16 in err-disable state
SILSSWC-WTTSL2(config-if-range)#
*Mar 1 02:26:54.010: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/14, changed state to down
*Mar 1 02:26:54.036: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/15, changed state to down
*Mar 1 02:26:54.052: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/16, changed state to down
*Mar 1 02:26:54.069: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/17, changed state to down
*Mar 1 02:26:54.094: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/18, changed state to down
*Mar 1 02:26:54.111: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/19, changed state to down
*Mar 1 02:26:54.128: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/20, changed state to down
SILSSWC-WTTSL2(config-if-range)#
Same again on port 5
====================
SILSSWC-WTTSL2#conf t
Enter configuration commands, one per line. End with CNTL/Z.
SILSSWC-WTTSL2(config)#int gi1/0/5
SILSSWC-WTTSL2(config-if)#shut
*Mar 1 02:28:14.113: %LINK-5-CHANGED: Interface GigabitEthernet1/0/5, changed state to administratively down
SILSSWC-WTTSL2(config-if)#no shut
SILSSWC-WTTSL2(config-if)#
*Mar 1 02:28:24.079: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/5, changed state to down
SILSSWC-WTTSL2(config-if)#^Z
SILSSWC-WTTSL2#dh
*Mar 1 02:28:31.654: %SYS-5-CONFIG_I: Configured from console by vty0 (100.0.0.199)
SILSSWC-WTTSL2#sh log
Syslog logging: enabled (0 messages dropped, 0 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)
No Active Message Discriminator.
I am trying to connect «sfp-1ge-fe-e-t» sfp module to CISCO Catalyst C3560G-48TS switch.
When i pluged module to the port and following error was shown:
%GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi0/49 has bad crc
Then I searched solution for the problem, so I found several solution that describes same steps.
like that:
how to connect 3rd party sfp to the cisco switches
I tried following commands:
# service unsupported-transceiver
# no errdisable detect cause sfp-config-mismatch
# no errdisable detect cause gbic-invalid
But it didn’t help actually. I couldn’t turn on GBIC ports. It always shows «status down, protocol down».
Even show idprom interface gigabitEthernet 0/49
command doesn’t show anything.
I have been experiencing with the proplem for two days.
Which steps should i follow? what is the real solution?
Thanks in advance
asked Jul 25, 2018 at 7:52
1
I’m afraid the real solution is to use either Cisco transceivers or third-party transceivers — from reputable vendors- that are specifically «tagged» to be used on Cisco switches.
Using random transceivers will only cause troubles and the time you will loose will vastly overcome the economy made on the hardware.
Edit:
As you can see in this datasheet the C3560G-48TS has SFP (1Gb) ports, not SFP+ (10Gb). So you cannot use a SFP+ transceiver like sfp-10g-sr
You can use this compatibility matrix to check which transceiver are compatible with your switch.
answered Jul 25, 2018 at 8:09
JFLJFL
19k1 gold badge31 silver badges64 bronze badges
3
You SFP has to be Cisco tagged.
Please note that some SFP supplier can provide a programmer to retag SFP on the fly.
We used this a lot, this is very convenient for spare management when you used mixed devices brands/models. Now we have lots of spare for every devices…
We use a specific programmer from a specific SFP vendor, but there is also generic solutions and DIY solutions (search SFP programmer on google)
answered Aug 1, 2018 at 21:03
GolgotGolgot
4272 silver badges9 bronze badges
try this command :
(note that you should type it and it is not auto complete )
# no errdisable detect cause gbic-inv service unsupported-transceiver
then remove SFP. then shut/no shut. then put it back.
if it doesn’t work try default the port:
conf t # default int gig1/1/1
if it doesn’t work, you should test all of combination of above command + physical job.
answered Jul 25, 2018 at 12:15
hamid bayathamid bayat
2042 silver badges8 bronze badges
4