Gbic security crypt 4 vn data crc error

GBIC_SECURITY_CRYPT through IPA

GBIC_SECURITY_CRYPT through IPA

GBIC_SECURITY_CRYPT through HAL_GENMEM

  • GBIC_SECURITY_CRYPT

  • GBIC_SECURITY_UNIQUE

  • GDOI

  • GENERIC_SUBBLOCK

  • GEN_DB

  • GEN_PROXY

  • GLBP

  • GRIP

  • HA

  • HAL_GENMEM

GBIC_SECURITY_CRYPT

%GBIC_SECURITY_CRYPT-4-UNRECOGNIZED_VENDOR : GBIC in port [dec] manufactured by an unrecognized vendor
Explanation

The GBIC was identified as a Cisco GBIC, but the system was unable to match its manufacturer with one on the known list of
Cisco GBIC vendors
Recommended Action

Check to see if the Cisco IOS software running on the system supports the GBIC. If the GBIC is newer, a system software upgrade
might be required.
%GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR : GBIC in port [dec] has bad crc
Explanation

The GBIC was identified as a Cisco GBIC, but it does not have valid CRC in the EEPROM data.
Recommended Action

Check to see if the Cisco IOS software running on the system supports the GBIC. If the GBIC is newer, a system software upgrade
might be required. Even if the GBIC is unrecognized by the system, the GBIC may still operate properly, but might have limited
functionality.
%GBIC_SECURITY_CRYPT-4-ID_MISMATCH : Identification check failed for GBIC in port [dec]
Explanation

The GBIC was identified as a Cisco GBIC, but the system was unable to verify its identity
Recommended Action

Check to see if the Cisco IOS software running on the system supports the GBIC. If the GBIC is newer, a system software upgrade
might be required. Otherwise, verify that the GBIC was obatined from Cisco or from a supported vendor.

GBIC_SECURITY_UNIQUE

%GBIC_SECURITY_UNIQUE-4-DUPLICATE_SN : GBIC interface [dec]/[dec] has the same serial number as another GBIC interface
Explanation

The GBIC was identified as a Cisco GBIC, but its serial number matches that of another interface on the system.
Recommended Action

Cisco GBICs are assigned unique serial numbers. Verify that the GBIC was obtained from Cisco or a supported vendor
%GBIC_SECURITY_UNIQUE-3-DUPLICATE_GBIC : GBIC interface [dec]/[dec] is a duplicate of GBIC interface [dec]/[dec]
Explanation

The GBIC was identified as a Cisco GBIC, but its vendor ID and serial number match that of another interface on the system.
Recommended Action

Cisco GBICs are assigned unique serial numbers. Verify that the GBIC was obtained from Cisco or a supported vendor

GDOI

%GDOI-1-GDOI_ACL_NUM : The ACL has too many entries. GDOI will honor only the first 100 ACL entries specified.
Explanation

The ACL has too many entries. GDOI will honor only the first 100 ACL entries specified.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-3-GDOI_ACL_RANGE : The ACL [chars] contains port range which is NOT supported. WARNING: No TEK policy will be created.
Explanation

GDOI does not support port range in the ACL policy.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-1-GDOI_ACE_DENY : A Group Member ACL policy containing deny was attempted. This is not supported.
Explanation

A Group Member ACL policy containing deny was attempted. This is not supported.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-1-UNREGISTERED_INTERFACE : Group [chars] received registration from unregistered interface.
Explanation

Receiving registration from unregistered interface. Stop processing it.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-1-UNAUTHORIZED_IDENTITY : Group [chars] received registration from unauthorized identity: [chars]
Explanation

The registration request was dropped because the requesting device was not authorized to join the group.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-1-UNAUTHORIZED_IPADDR : Group [chars] received registration from unauthorized ip address: [chars]
Explanation

The registration request was dropped because the requesting device was not authorized to join the group.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-4-GM_RE_REGISTER : The IPSec SA created for group [chars] may have expired/been cleared, or didn’t go through. Re-register
to KS.
Explanation

The IPSec SA created for one group may have expired/been cleared, or didn’t go through, need to re-register to KS.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-GM_REGS_COMPL : Registration to KS [chars] complete for group [chars] using address [chars] fvrf [chars] ivrf [chars]
Explanation

Complete registration
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-GM_FAILED_TO_INSTALL_POLICIES : FAILED: Installation of Reg/Rekey policies from KS [chars] for group [chars] & gm
identity [chars]
Explanation

Failed Policy installation
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-GM_INSTALL_POLICIES_SUCCESS : SUCCESS: Installation of Reg/Rekey policies from KS [chars] for group [chars] & gm
identity [chars] fvrf [chars] ivrf [chars]
Explanation

Policy Installation Success
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-GM_RECV_REKEY : Received Rekey for group [chars] from [chars] to [chars] with seq # [dec], spi [hex][hex]
Explanation

Received Rekey
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-KS_SEND_MCAST_REKEY : Sending Multicast Rekey [chars]for group [chars] from address [chars] to [chars] with seq #
[dec] spi: [hex][hex]
Explanation

Sending Multicast Rekey
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-KS_SEND_UNICAST_REKEY : Sending Unicast Rekey [chars]for group [chars] from address [chars] with seq # [dec] spi:
[hex][hex]
Explanation

Sending Unicast Rekey
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-3-KS_BAD_ID : Registration: [chars] config mismatch between KS and the GM [IP_address], in the group [chars].
Explanation

During GDOI registration protocol, a configuration mismatch between local key server and group member.
Recommended Action

Contact the Group member’s administrator.
%GDOI-3-GDOI_REKEY_FAILURE : Processing of REKEY payloads failed on GM [chars] in the group [chars], with peer at [chars]
Explanation

During GDOI rekey the payload parsing failed on this GM from the Key Server.
Recommended Action

Contact the Group member’s administrator.
%GDOI-3-GDOI_REKEY_SEQ_FAILURE : Failed to process rekey seq # [int] in seq payload for group [chars], last seq # [int]
Explanation

During GDOI rekey the seq payload parsing failed on this GM from the Key Server.
Recommended Action

Contact the Group member’s administrator.
%GDOI-4-KS_GM_REJECTS_SA_PAYLOAD : Registration: GM [IP_address] rejected a policy in the SA proposal sent by KS, in the
group [chars].
Explanation

During GDOI registration protocol, a proposal sent by the key server was refused by the group member.
Recommended Action

Contact the Group member’s administrator.
%GDOI-4-GM_REJECTING_SA_PAYLOAD : Registration: Policy in SA payload sent by KS [IP_address] rejected by GM in the group
[chars] reason [chars].
Explanation

During GDOI registration protocol, a proposal sent by the key server was refused by the local group member.
Recommended Action

Contact the Key server’s administrator.
%GDOI-4-KS_HASH_FAIL : Registration: Bad(No) Hash in Message sent by the GM [IP_address] to KS in the group [chars].
Explanation

During GDOI registration protocol, a message sent by the Group member has bad or no hash .
Recommended Action

Contact the Group member’s administrator.
%GDOI-4-GM_HASH_FAIL : Registration: Bad(No) hash in message sent by the KS [IP_address] to GM in the group [chars].
Explanation

During GDOI registration protocol, a message sent by the Key server has bad or no hash .
Recommended Action

Contact the Key Server’s administrator.
%GDOI-3-KS_UNAUTHORIZED : Registration: Unauthorized [IP_address] tried to join the group [chars].
Explanation

During GDOI registration protocol, an unauthorized member tried to join a group Some might consider this a hostile event.
Recommended Action

Contact the Key Server’s administrator.
%GDOI-3-KS_GM_REVOKED : Re-Key: GM [IP_address] revoked by KS in the group [chars].
Explanation

During Re-key protocol, an unauthorized member tried to join a group. Some might consider this a hostile event.
Recommended Action

Contact the Key Server’s administrator.
%GDOI-5-KS_GROUP_ADD : Config: KS [IP_address] added to the Group [chars].
Explanation

A Config command has been executed to add a Key Server in a group
Recommended Action

Informational message.
%GDOI-5-KS_GROUP_DELETE : Config: KS [IP_address] removed from the Group [chars].
Explanation

A Config command has been executed to remove a Key Server from a group
Recommended Action

Informational message.
%GDOI-6-KS_FIRST_GM : Re-key: First GM [IP_address] seen by KS in the group [chars].
Explanation

Local key server has received the first group member joining the group
Recommended Action

Informational message.
%GDOI-6-KS_LAST_GM : Re-key: Last GM [IP_address] left the group [chars].
Explanation

Last group member has left the group on the local key server
Recommended Action

Informational message.
%GDOI-5-GM_CM_ATTACH : Crypto map attached for GM in group [chars].
Explanation

A crypto map has been attached for the local group member.
Recommended Action

Informational message.
%GDOI-5-GM_CM_DETACH : Crypto map detached for GM in group [chars].
Explanation

A crypto map has been detached for the local group member.
Recommended Action

Informational message.
%GDOI-5-GM_UNREGISTER : GM left the group [chars].
Explanation

A Group member has left the group.
Recommended Action

Informational message.
%GDOI-4-GM_RECV_POLICY_REPLACE_NOW : GM received policy replace now rekey from KS in group [chars].
Explanation

A messages sent by the KS to immediately replace SAs policies on the GM has been received.
Recommended Action

Informational message.
%GDOI-4-GM_RECV_DELETE_IMMEDIATE : GM receive REMOVAL-NOW in group [chars] to cleanup downloaded policy now. Re-registration
will start in a randomly chosen period of [dec] sec
Explanation

A messages sent by the KS to delete the GM has been received.
Recommended Action

Informational message.
%GDOI-4-GM_RECV_RE_AUTH : GM received Re-auth-msg from KS in group [chars]. re-registration will start before SA expiry
Explanation

A message sent by the KS to have a GM re-auth has been received.
Recommended Action

Informational message.
%GDOI-4-GM_RECV_DELETE : GM received delete-msg from KS in group [chars]. TEKs lifetime are reduced and re-registration will
start before SA expiry
Explanation

A messages sent by the KS to delete the GM has been received.
Recommended Action

Informational message.
%GDOI-5-GM_CLEAR_REGISTER : Config: GM cleared gdoi configuration for the group [chars].
Explanation

clear crypto gdoi command has been executed by the local GM
Recommended Action

Informational message.
%GDOI-5-KS_CLEAR_REGISTER : Config: KS cleared gdoi configuration for the group [chars].
Explanation

clear crypto gdoi command has been executed by the local KS
Recommended Action

Informational message.
%GDOI-3-COOP_KS_UNREACH : Cooperative KS [chars] Unreachable in group [chars]. IKE SA Status = [chars]
Explanation

The reachability between the configugred cooperative key servers is lost. Some might consider this a hostile event.
Recommended Action

Contach the Administrator(s) of the configured key servers.
%GDOI-5-COOP_KS_REACH : Reachability restored with Cooperative KS [chars] in group [chars].
Explanation

The reachability between the configugred cooperative key servers is restored.
Recommended Action

Informational message
%GDOI-5-COOP_KS_ADD : [chars] added as COOP Key Server in group [chars].
Explanation

A key server has been added to the list of cooperative key servers in a group
Recommended Action

Informational message
%GDOI-5-COOP_KS_REMOVE : [chars] removed as COOP Key Server in group [chars].
Explanation

A key server has been removed from the list of cooperative key servers in a group
Recommended Action

Informational message
%GDOI-4-COOP_KS_UNAUTH : Contact from unauthorized KS [chars] in group [chars] at local address [chars] (Possible MISCONFIG
of peer/local address)
Explanation

An unauthorized remote server tried to contact the local KS may be at different key server address in a group. Some might
consider this a hostile event.
Recommended Action

Informational message
%GDOI-5-COOP_KS_ELECTION : KS entering election mode in group [chars] (Previous Primary = [chars])
Explanation

The local Key server has entered the election process in a group
Recommended Action

Informational message
%GDOI-5-COOP_KS_TRANS_TO_PRI : KS [chars] in group [chars] transitioned to Primary (Previous Primary = [chars])
Explanation

The local Key server transitioned to a primary role from being a secondary server in a group
Recommended Action

Informational message
%GDOI-5-COOP_KS_ADMN_USRP_PRI : Primary role Usurped by KS [chars] in group [chars].
Explanation

A network adminstrator has made the local KS as primary, by means of a CLI command. Currently Unimplemented.
Recommended Action

Informational message
%GDOI-5-GM_REKEY_TRANS_2_MULTI : Group [chars] transitioned to multicast rekey.
Explanation

GM has transitioned from using unicast rekey mechanism to multicast mechanism
Recommended Action

Informational message
%GDOI-5-KS_REKEY_TRANS_2_MULTI : Group [chars] transitioned to multicast rekey.
Explanation

Group has transitioned from using unicast rekey mechanism to multicast mechanism
Recommended Action

Informational message
%GDOI-5-GM_REKEY_TRANS_2_UNI : Group [chars] transitioned to Unicast Rekey.
Explanation

GM has transitioned from using multicast rekey mechanism to unicast mechanism
Recommended Action

Informational message
%GDOI-5-KS_REKEY_TRANS_2_UNI : Group [chars] transitioned to Unicast Rekey.
Explanation

Group has transitioned from using multicast rekey mechanism to unicast mechanism
Recommended Action

Informational message
%GDOI-4-GM_REKEY_NOT_RECD : GM did not receive rekey from KS [IP_address] in group [chars].
Explanation

GM has not received a rekey message from a key server in a group Currently Unimplemented.
Recommended Action

Informational message
%GDOI-5-KS_NACK_GM_EJECT : KS ejected GM [IP_address] in group [chars].
Explanation

Key server has reached a condition of not receiving an ACK from GM and has been ejected
Recommended Action

Informational message
%GDOI-3-KS_BLACKHOLE_ACK : KS blackholing GM [IP_address] in group [chars].
Explanation

Key server has reached a condition of blackholing messages from GM Some might consider this a hostile event.
Recommended Action

%GDOI-4-KS_UNSOL_ACK : KS received unsolicited ACK from GM [IP_address] in group [chars].
Explanation

Key server has received an unsolicited ACK from a past GM or is under a DOS attack. Some might consider this a hostile event.
Recommended Action

%GDOI-5-KS_REGS_COMPL : KS completed successful registration in group [chars] with GM [IP_address].
Explanation

Key server has successfully completed a registration in a group
Recommended Action

%GDOI-5-GM_ENABLE_GDOI_CM : GM has enabled ACL on GDOI crypto map in group [chars].
Explanation

Group member has enabled ACL on a GDOI Crypto map in a group with a key server
Recommended Action

%GDOI-5-GM_ACL_MERGE : ACL betweem KS and GM in group [chars] merged.
Explanation

The ACL differences between GM and KS are resolved and a merge took place
Recommended Action

%GDOI-5-GM_SA_INGRESS : Receive only ACL received from KS [IP_address] in group [chars].
Explanation

Received only acl has been received by GM from a KS in a group
Recommended Action

%GDOI-5-KS_CONV_SAS_DUPLEX : IPSec SAs converted to Duplex in group [chars].
Explanation

IPSec SAs have been converted to bidirectional mode in a group
Recommended Action

%GDOI-5-KS_CONV_SAS_INGRESS : IPSec SAs converted to Ingress in group [chars].
Explanation

IPSec SAs have been converted to receive only mode in a group
Recommended Action

%GDOI-5-GM_CONV_SA_DUPLEX : IPSec SAs converted to Duplex in group [chars] on the GM.
Explanation

IPSec SAs have been converted to bidirectional mode in a group on a GM
Recommended Action

%GDOI-5-GM_CONV_SA_DUPLEX_LOCAL : IPSec SAs converted to Duplex in group [chars] on a GM by a local event.
Explanation

IPSec SAs have been converted to bidirectional mode in a group on a GM by a CLI command
Recommended Action

%GDOI-5-LKH_ENABLE : LKH enabled in group [chars].
Explanation

LKH has been enabled in a group
Recommended Action

%GDOI-5-LKH_DISABLE : LKH disabled in group [chars].
Explanation

LKH has been disabled in a group
Recommended Action

%GDOI-4-LKH_GM_DELETE : GM [IP_address] deleted from LKH in group [chars].
Explanation

A Group member has been deleted in a group from LKH
Recommended Action

%GDOI-4-TIMEBASED_REPLAY_FAILED : An anti replay check has failed in group [chars]: my_pseudotime = [chars], peer_pseudotime
= [chars], replay_window = [dec] (sec), src_ip = [IP_address], dst_ip = [IP_address]
Explanation

A Group member or Key server has failed an anti replay check.
Recommended Action

%GDOI-3-PIP_PSEUDO_TIME_ERROR : An Anti-Replay check has failed for PIP in group [chars]: my_pseudotime = [chars], peer_pseudotime
= [chars], replay_window = %lld (sec), src_addr = [chars], dst_addr = [chars]
Explanation

A Group member has failed PIP anti replay check.
Recommended Action

%GDOI-3-P2P_KGS_INFRA_ERROR : PIP session with [chars] failed because of KGS Infra failure. Reason = [chars]
Explanation

A Group Member has encountered a KGS Infra failure.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-4-TIMEBASED_REPLAY_FAILED_IPV6 : An anti replay check has failed in group [chars]: my_pseudotime = [chars], peer_pseudotime
= [chars], replay_window = [dec] (sec), src_ip = [IPV6 address], dst_ip = [IPV6 address]
Explanation

A Group member or Key server has failed an anti replay check.
Recommended Action

%GDOI-3-GM_FAILED_TO_INITIALISE : GDOI GM Process has failed to initialise
Explanation

GDOI Group Member process has failed to initialise on this Network Element
Recommended Action

%GDOI-3-PSEUDO_TIME_LARGE : Pseudotime difference between KS ([dec] sec) and GM ([dec] sec) is larger than expected in group
[chars]. Adjust to new PST
Explanation

A Group member has received pseudotime which has large difference as compared to own pseudotime
Recommended Action

%GDOI-3-PSEUDO_TIME_TOO_OLD : Rekey received in group [chars] is too old and fail PST check: my_pst is [dec] sec, peer_pst
is [dec] sec, allowable_skew is [dec] sec
Explanation

A Group member has received pseudotime which has large difference as compared to own pseudotime
Recommended Action

%GDOI-3-GM_INCOMPLETE_CFG : Registration: incomplete config for group [chars]
Explanation

Registration can not be completed since the GDOI group configuration may be missing the group id, server id, or both
Recommended Action

Contact the Group member’s administrator.
%GDOI-1-KS_NO_RSA_KEYS : RSA Key — [chars] : Not found, Required for group [chars]
Explanation

Rsa Keys were not found in Key Server and they are required for signing and verifying rekey messages
Recommended Action

Contact the Key Server’s administrator and ask him to do create the RSA Key pair
%GDOI-4-RSA_KEYS_MODIFIED : WARNING: GMs for group [chars] will re-register due to signature verification failure
Explanation

Rekeys will be dropped by GM as signature verification would fail due to modification of RSA Keys
Recommended Action

Informational message
%GDOI-3-KS_REKEY_AUTH_KEY_LENGTH_INSUFFICIENT : Rejected [chars] change: using sig-hash algorithm [chars] requires an authentication
key length of at least [int] bits ([int] blocks in bytes) — [chars] [chars] key [chars] is only [int] blocks in bytes
Explanation

Using a sig-hash algorithm for rekeys requires that the RSA key modulus length for the rekey authentication be at least the
length of the hash generated by the sig-hash algorithm plus some padding bytes. If the RSA key modulus length is not large
enough, the Key Server administrator needs to generate a new RSA key pair wit a sufficient length.
Recommended Action

Contact the Key Server’s administrator to re-generate the RSA key pair with at least the modulus length given in the syslog.
%GDOI-3-COOP_CONFIG_MISMATCH : WARNING: Group [chars], [chars] configuration between Primary KS and Secondary KS are mismatched
Explanation

The configuration between Primary KS and Secondary KS are mismatched
Recommended Action

Contact the Key Sever’s administrator
%GDOI-3-GM_ACL_PERMIT : GM doesn’t support permit configured under local access-list. Traffic from [chars] to [chars] will
be dropped.
Explanation

GM can only support ACL for deny. Any traffic matching the permit entry will be dropped.
Recommended Action

Remove the permit entry from the ACL used by GDOI crypto map
%GDOI-3-GM_NO_IPSEC_FLOWS : IPSec FLOW limit possibly reached
Explanation

Hardware Limitation for IPSec Flow limit Reached. Cannot create any more IPSec SAs
Recommended Action

Contact the Group member’s administrator.
%GDOI-3-GM_NO_CRYPTO_ENGINE : No crypto engine is found due to lack of resource or unsupported feature requested
Explanation

Failed to select a suitable crypto engine because requested packet path not available, or requested feature not supported
Recommended Action

Check policy configured on KS
%GDOI-3-COOP_PACKET_DROPPED : Announcement message dropped due to packet size [dec] bytes.
Explanation

Hard limit set on the driver buffer size prevents sending packets of this size or bigger
Recommended Action

Informational message
%GDOI-3-UNEXPECTED_SIGKEY : Unexpected Signature Key detected: freeing it
Explanation

Unexpected Signature Key found: freeing the signature key
Recommended Action

Informational message
%GDOI-3-UNSUPPORTED_TEK_PROTO : Unexpected TEK Protocol : [dec]
Explanation

Unexpected TEK PROTOCOL
Recommended Action

Informational message
%GDOI-4-GM_DELETE : GM [chars] deleted from group [chars].
Explanation

A group member has been deleted in a group from Key Server
Recommended Action

Informational message
%GDOI-5-KS_USING_DEFAULT_TRANSFORM : GETVPN is using default transforms for profile [chars]
Explanation

Using default transformset
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-GM_REKEY_CIPHER_HASH_CHECK_FAIL : Rekey cipher/hash ([chars]) used in Group [chars] is unacceptable by this client.
Explanation

The key-server has chosen KEK rekey cipher/hash algorithms which are not acceptable by this group-member
Recommended Action

Contact the Key server’s administrator.
%GDOI-5-GM_REKEY_TRANSFORMSET_CHECK_FAIL : The transformset ([chars]) for data-protection in Group [chars] is unacceptable
by this client.
Explanation

The key-server has chosen a TEK transformset which is not acceptable by this group-member
Recommended Action

Contact the Key server’s administrator.
%GDOI-3-COOP_ANN_SEQ_FAILURE : COOP Ann msg seq check failed for group [chars], ann seq# [int], sess seq# [int]
Explanation

COOP Ann msg seq check failed
Recommended Action

Contact Administrator
%GDOI-4-GDOI_ANN_TIMESTAMP_TOO_OLD : COOP_KS ANN from KS [chars] in group [chars] is too old and fail PST check: my_pst is
[int] sec, peer_pst is [int] sec, allowable_skew is [dec] sec
Explanation

The KS has received an ANN msg from a primary KS in which the timestamp is too old
Recommended Action

%GDOI-4-GDOI_ANN_TIMESTAMP_LARGE : COOP_KS ANN received from KS [chars] in group [chars] has PST bigger than myself. Adjust
to new PST: my_old_pst is [int] sec, peer_pst is [int] sec
Explanation

The KS receive an ANN from a KS in which the timestamp is bigger than expected; also update my PST to peer’s
Recommended Action

%GDOI-4-GDOI_ANN_TIMESTAMP_LARGE_NO_UPDATE : COOP_KS ANN received from KS [chars] in group [chars] has PST bigger than myself:
my_pst is [int] sec, peer_pst is [int] sec
Explanation

The KS receive an ANN from a KS in which the timestamp is bigger than expected; No update of my PST
Recommended Action

%GDOI-4-GDOI_ANN_INCONSISTENT_TBAR : COOP_KS ANN received from [chars] in group [chars] has inconsistent TBAR setting inconsistent
than mine
Explanation

The KS has received an ANN msg from a secondary KS in which the timestamp is too old
Recommended Action

%GDOI-5-COOP_KS_VALID_ANN_TIMER_EXPIRED : This sec-KS has NOT received an ANN with valid PST for an extended period in group
[chars]. It will block new GMs registration temporarily until a valid ANN is received
Explanation

No valid ANN message has been received in this secondary KS for a prolong period. Temporarily blocking new GM registrations
until a valid ANN is received
Recommended Action

Informational message
%GDOI-5-COOP_KS_BLOCK_NEW_GM_REGISTER_ANN : This KS temporarily blocks GM with ip-addr [chars] from registering in group
[chars] as it has not received an ANN with valid PST for prolonged period
Explanation

No valid ANN message has been received in this secondary KS for a prolong period. Temporarily blocking new GM registrations
until a valid ANN is received
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-COOP_KS_BLOCK_NEW_GM_REGISTER_ELECTION : This KS temporarily blocks GM with ip-addr [chars] from registering in group
[chars] as the KS election is underway
Explanation

The KS is in the process of electing a primary. Temporarily blocking new GM registrations until the election is complete
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-COOP_KS_BLOCK_NEW_GM_REGISTER_KSSID : This KS is blocking GM with ip-addr [chars] from registering in group [chars]
as it has overlapping KS Sender Identifier(s) (KSSID) with another COOP-KS peer (MISCONFIG)
Explanation

Another COOP-KS peer in the group has been configured with a KSSID value that is the same as one configured on this KS. GM
registration is blocked as a result until the overlap is fixed.
Recommended Action

Check the configured KSSID(s) for all COOP-KS peers by issuing ‘show crypto gdoi ks coop ident detail’ on the primary KS
%GDOI-5-COOP_KS_RESUME_NEW_GM_REGISTER : This KS will now resume new GM registration functionality in group [chars]
Explanation

This KS will now resume new GM registration functionality
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-SA_KEK_UPDATED : SA KEK was updated [hex][hex][hex][hex]
Explanation

KEK was updated in the Registration/Rekey and a new KEK SA was created
Recommended Action

Informational message.
%GDOI-5-SA_PIP_UPDATED : SA PIP was updated 0x[chars]
Explanation

PIP was updated in Registration/Rekey and a new PIP SA was created
Recommended Action

Informational message.
%GDOI-3-SA_KEK_INSATALL_FAILED : Failed to install KEK SA
Explanation

KEK SA instalation has failed
Recommended Action

Informational message.
%GDOI-3-P2P_PEER_MIGRATE_FAILED : Failed to install P2P rekey SA with peer [chars] in group [chars]
Explanation

Installation of P2P Rekey SA with an existing peer has failed
Recommended Action

Check the status of all peers using the command ‘show crypto gdoi gm p2p peers’ and wait for PIP initiation between the failed
peers. Traffic distruption may occur.
%GDOI-5-SA_TEK_UPDATED : SA TEK was updated
Explanation

TEK was updated in the Registration/Rekey and a new TEK IPSEC SA was created
Recommended Action

Informational message.
%GDOI-4-GM_MINOR_VERSION_MISMATCH : GM [IP_address] Minor Version mismatch. Use ‘show crypto gdoi ks members’ to see GM versions
Explanation

GM has different minor version.
Recommended Action

show crypto gdoi ks members
%GDOI-3-GM_MAJOR_VERSION_MISMATCH : GM [IP_address] registration rejected due to major version mismatch. GM must be using
major version [dec] in order to be compatible with this KS
Explanation

GM has a non-compatible major version.
Recommended Action

Check GDOI version compatibility on KS and GMs
%GDOI-4-KS_MINOR_VERSION_MISMATCH : COOP-KS Minor Version mistmatch in group [chars]. My version is [dec].[dec].[dec], peer
[chars] has version [dec].[dec].[dec]
Explanation

Coop KS has different minor version.
Recommended Action

show crypto gdoi ks coop
%GDOI-3-KS_MAJOR_VERSION_MISMATCH : COOP-KS Major Version mismatch in group [chars]. My version is [dec].[dec].[dec], peer
[chars] has version [dec].[dec].[dec]
Explanation

COOP-KS has a non-compatible major version.
Recommended Action

Check GDOI version compatibility on KS
%GDOI-2-COOP_MINOR_VERSION_MISMATCH : COOP-KS Minor version mistmatch in group [chars]. My COOP version is [dec].[dec].[dec],
peer [chars] has version [dec].[dec].[dec]. Upgrade [chars] [chars] to COOP version [dec].[dec].[dec] to prevent COOP outage.
Explanation

Coop KS has different minor version.
Recommended Action

show crypto gdoi ks coop
%GDOI-3-COOP_MAJOR_VERSION_MISMATCH : COOP-KS Major Version mismatch in group [chars]. My version is [dec].[dec].[dec], peer
[chars] has version [dec].[dec].[dec]
Explanation

COOP-KS has a non-compatible major version.
Recommended Action

Check COOP version compatibility on KS
%GDOI-3-COOP_LIMIT_REACHED : Peer [chars] has reached COOP limit of maximum number of gms. COOP GM database sync fails. Upgrade
to COOP version [dec].[dec].[dec] and above
Explanation

COOP-KS has a non-compatible peer.
Recommended Action

Check COOP version compatibility on peer KS
%GDOI-5-POLICY_CHANGE : GDOI group [chars] policy has changed. Use ‘crypto gdoi ks rekey’ to send a rekey, or the changes
will be send in the next scheduled rekey
Explanation

Reminder message that GDOI configuration has changed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-ESON_POLICY_CHANGE_RESTART1 : ESON group [chars] policy has changed. Must use ‘clear crypto gdoi ks members now’
to restart the group
Explanation

Reminder message that ESON configuration has changed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-ESON_POLICY_CHANGE_RESTART2 : ESON group [chars] policy has changed. Must use ‘crypto gdoi ks replace now’ to restart
the group
Explanation

Reminder message that ESON configuration has changed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-GM_DELETE_EXPIRED_KEK : KEK expired for group [chars] and was deleted
Explanation

Deleting Expired KEK
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-GM_DELETE_EXPIRED_PIP : PIP with SPI 0x[chars] expired for group [chars] and was deleted
Explanation

Deleting Expired PIP
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-GM_DELETE_EXPIRED_P2P : P2P SA with epoch hash 0x[chars] expired for group [chars] and was deleted
Explanation

Deleting Expired P2P
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-POLICY_CHANGE_TO_SUITEB : Group [chars] changed to Suite-B policy. Use ‘crypto gdoi ks rekey’ to generate the new
Suite-B policy and cause all GMs to re-register to download SIDs, or this will happen in the next scheduled rekey
Explanation

Migrating from non-Suite-B to Suite-B policy requires that the user issues ‘crypto gdoi ks rekey’ like any other POLICY_CHANGE,
but this will cause a re-initialization rather than just a rekey.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-KS_REINIT_GROUP : [chars] for group [chars] and will re-initialize the group.
Explanation

KS has reached one of the following conditions (indicated by the first part of the message) requiring re-initialization of
the group: — Group Size configuration changed — Previously used KSSID removed from configured KSSID set — KS runs out of KSSIDs
& GMSIDs — COOP SID client gets a re-initialization indication from COOP-KS — KSSID overlap detected by COOP is resolved —
TEK policy is changed from non-CTR to CTR (SIDs required).
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-KS_REINIT_FINISH : Re-initialization of group [chars] completed.
Explanation

A previously triggered re-initialization, as signified by a %GDOI-5-KS_REINIT_GROUP syslog, has completed after the expiry
of the old TEK.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-3-KS_NO_SID_AVAILABLE : GMs for group [chars] need SIDs but this KS has no KS SIDs configured or no more SIDs available.
Explanation

This KS has a counter-mode transform configured requiring SIDs and either has no KSSIDs configured or has run out of SIDs.
Registering GMs will not be able to register successfully until more KSSIDs are configured on this KS.
Recommended Action

Check the configured KSSID(s) for this KS by issuing ‘show crypto gdoi ks ident detail’ and consider configuring more KSSIDs
using the ‘identifier’ sub-mode under ‘server local’.
%GDOI-3-COOP_KSSID_OVERLAP : Overlapping KS Sender Identifier(s) (KSSID) {[chars]} with COOP-KS peer [chars] in group [chars]
blocking GM registration (MISCONFIG)
Explanation

Another COOP-KS peer in the group has been configured with a KSSID value that is the same as one configured on this KS. GM
registration is blocked as a result until the overlap is fixed.
Recommended Action

Check the configured KSSID(s) for all COOP-KS peers by issuing ‘show crypto gdoi ks coop ident detail’ on the primary KS
%GDOI-5-COOP_KSSID_OVERLAP_RESOLVED : Resolved overlapping KS Sender Identifier(s) (KSSID) with COOP-KS peer allowing GM
registrations once again
Explanation

Another COOP-KS peer in the group had been configured with a KSSID value that was the same as one configured on this KS, but
has been resolved so that GM registration is allowed again.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-GM_IV_EXHAUSTED : GM for group [chars] exhausted its IV space for interface [chars] and will re-register.
Explanation

One of the interfaces where a CTR transform (e.g. GCM-AES / GMAC-AES) has been installed as TEK policy with SIDs has exhausted
its IV space & must re-register to receive new SIDs.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-GM_REKEY_IPV4_POLICY_CHECK_FAIL : Non-IPv4 policies is received in IPv4 Group [chars]; rekey is rejected
Explanation

This GM is registering to an IPv4 group but erroneously receiving IPv6 policies in rekey
Recommended Action

Contact the Key server’s administrator.
%GDOI-5-GM_REKEY_IPV6_POLICY_CHECK_FAIL : Non-IPv6 policies is received in IPv6 Group [chars]; rekey is rejected
Explanation

This GM is registering to an IPv6 group but erroneously receiving IPv4 policies in rekey
Recommended Action

Contact the Key server’s administrator.
%GDOI-4-UNKNOWN_GM_VERSION_REGISTER : WARNING: GM [IP_address] with unknown GDOI ver registered to group [chars] (e.g old-IOS
or non-Cisco GM please check ‘show crypto gdoi ks members’ and ‘show crypto gdoi feature’ to ensure all your GMs can support
the GETVPN features enabled.
Explanation

A GM is registered with unknown GDOI SW version; cannot determine its feature capability.
Recommended Action

Check GMs can support all GETVPN features enabled in KS. Also check output of ‘show crypto gdoi feature’ and ‘debug crypto
gdoi ks infra detail’ (note: high volume of debugs). msgdef_ddts_component(ipsec-getvpn)
%GDOI-4-NEWER_GM_VERSION_REGISTER : WARNING: GM [IP_address] registers to group [chars] with newer GDOI version than KS.
Please check’show crypto gdoi ks members’ and ‘show crypto gdoi feature’ to ensure all GMs can support the GETVPN features
enabled.
Explanation

A GM is registered with newer GDOI SW version; cannot determine its feature capability.
Recommended Action

Check GMs can support all GETVPN features enabled in KS. Also check output of ‘show crypto gdoi feature’ and ‘debug crypto
gdoi ks infra detail’ (note: high volume of debugs). msgdef_ddts_component(ipsec-getvpn)
%GDOI-4-REJECT_GM_VERSION_REGISTER : Reject registration of GM [IP_address] (ver [hex]) in group [chars] as it cannot support
these GETVPN features enabled: [chars]
Explanation

Reject GM registration because it cannot support the GETVPN features enabled in the group.
Recommended Action

Check GMs can support all GETVPN features enabled in KS. Also check output of ‘show crypto gdoi feature’ and ‘debug crypto
gdoi ks infra detail’ (note: high volume of debugs). msgdef_ddts_component(ipsec-getvpn)
%GDOI-4-GM_RECOVERY_REGISTRATION : GM recovery re-registration for group [chars] will start in a randomly chosen period of
[dec] sec
Explanation

GM recovery feature detects dataplane error and will re-register to KS to refresh keys and policy
Recommended Action

Informational message.
%GDOI-4-GM_RECOVERY_REGISTRATION_POSTPONED : Detects data error in group [chars] but the previous recovery/rekey has occured
within the last recovery-check interval. Postpone recovery registration to start in [dec] sec
Explanation

GM recovery feature detects dataplane error and will re-register to KS to refresh keys and policy
Recommended Action

Informational message.
%GDOI-4-GM_SA_TRACK_SET_EOT_ERROR : Group [chars] encountered error in setting EOT object ID [dec] to state [chars].
Explanation

GM SA TRACK state change occur but fail to update EOT object ID accordingly
Recommended Action

Informational message. Check to make sure the EOT object ID is configured properly
%GDOI-5-POLICY_CHANGE_ERROR_MULTIPLE_PORTS : Multiple ports detected for ACL [chars] which is not supported. WARNING: No
TEK policy will be created.
Explanation

Informs user that there is an error in the ACL with regards to the number of ports.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-6-COOP_KS_VER_TRANSIT : Coop KS [chars] protocol version transits from version 1.0.1 to 2.0.0
Explanation

The KS is transitioning to a new version.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-4-COOP_KS_RBLY_FAILED : Coop KS [chars] in group [chars] session Reassembly failed in TransID [int]
Explanation

The KS COOP had an error reassmbling a packet from a peer KS
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-4-COOP_KS_CHECKPT_MISMATCH : Coop KS [chars] in group [chars] received Checkpoint Mismatch message.
Explanation

The KS COOP had received a checkpoint mismatch from a KS COOP peer
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-3-COOP_KS_CANNOT_FIND_PROFILE : Coop KS in group [chars] has a configured IKEv2 profile ‘[chars]’ that doesn’t exist.
The COOP will not come up until this error is fixed.
Explanation

The KS COOP coniguration redunadancy ikve2-profile specifies a profile that doesn’t exist. The COOP will not come up.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-IPSEC_INITIATE_GM_REGISTER : IPSEC initiate GDOI group [chars] to register
Explanation

IPSEC initiate a GM registration for the group
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-3-IPSEC_INITIATE_GM_REGISTER_POSTPONE : IPSEC triggering registration for group [chars] too frequently. Postpone the
registration to occur in [dec] msec.
Explanation

GM detects IPSEC triggering registration for the group too frequently. GDOI will rate-limit and postpone the registration.
Recommended Action

Contact the Group member’s administrator.
%GDOI-3-IPSEC_INITIATE_GM_REGISTER_IGNORE : IPSEC triggering registration for group [chars] too frequently. Ignore the request
as registartion has already been scheduled to occur in [dec] msec.
Explanation

GM detects IPSEC triggering registration for the group too frequently. GDOI will ignore the request as registration has already
been scheduled.
Recommended Action

Contact the Group member’s administrator.
%GDOI-3-COOP_KS_TOO_MANY_GROUPS_SHARE_IKE_SA : The COOP KS has too many groups sharing the same IKE SA for the peer addresses
local [chars] remote [chars]. Connectivity could be compromised. Please reduce to [dec].
Explanation

There is a limit to the number of COOP KS groups that can share the. same IKE SA. This can lead to intermittent connectivity
for the COOP KS in congested networks
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-3-COOP_KS_SEND_WINDOW_LIMIT_REACHED : The COOP KS has reached its window limit for the peer addresses local [chars]
remote [chars]. This is due to connectivity issues between the key servers in question.
Explanation

The COOP KS running over IKEv2 has a limit to the number of pending messages that can be sent. This limit has been reached
which is an indication that there is a connectivity issue between the key servers
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-4-REJECT_GM_CKM_REGISTER : Reject registration of GM [IP_address] in group [chars] as it has CKM enabled but this secondaryKS
has not sync up all KGS params yet
Explanation

Reject GM registration because this is a secondaryKS and it has not received KGS seed and rekey-epoch from primaryKS yet
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-4-COOP_KS_CKM_INCOMPATIBLE : Found incompatible COOP-KS that cannot support CKM in group [chars]. Please check ‘show
crypto gdoi feature ckm’and upgrade the incompatible KS immediately.
Explanation

Found incompatible COOP-KS that cannot support CKM in the group. Network administrator should check ‘show crypto gdoi feature
ckm’and upgrade the incompatible KS immediately
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-5-GM_REGISTER_UPDATE_TBAR : Platform HA forwarding-plane comes online, group [chars] gm-identity [chars] fvrf [chars]
ivrf [chars] re-register to refresh TBAR info.
Explanation

HA forwarding-plane comes online, group %s gm-identity %s fvrf %s ivrf %s is re-registering to refresh TBAR info.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GDOI-3-GM_IPD3P_NO_IPV6_SUPPORT : GETVPN group-member does not support IP-D3P for IPv6.
Explanation

GETVPN group-member does not support IP-D3P for IPv6.
Recommended Action

Contact the Administrator(s) to correct the key server policy.
%GDOI-3-GM_IPD3P_NO_TRANSPORT_SUPPORT : GETVPN group-member does not support IPD3P transport mode
Explanation

GETVPN group-member does not support IPD3P transport mode
Recommended Action

Contact the Administrator(s) to correct the key server policy.
%GDOI-3-GM_IPD3P_AND_CMD_CANT_COEXIST : GETVPN group-member does not support coexistance of IPD3P and Cisco-metadata features
Explanation

GETVPN group-member does not support the enabling of IPD3P and Cisco-metadata features (e.g TBAR-PST, SGT) at the time
Recommended Action

Contact the Administrator(s) to correct the key server policy.

GENERIC_SUBBLOCK

%GENERIC_SUBBLOCK-2-LATE_REGISTER : Late registration of GSB type [chars], with id [dec]
Explanation

An attempt to register a new generic subblock type was received after subblocks have already been allocated from the control
structure with previously registered types
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GENERIC_SUBBLOCK-2-BUILDXDR : Failed to build message for GSB: [chars]
Explanation

An attempt to build a message for distribution of generic subblock failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GENERIC_SUBBLOCK-2-UNPACKXDR : Unpacked [dec] bytes and attempted to consume [dec] bytes for GSB: [chars]
Explanation

A discrepancy was detected between length of message expected versus length of message received
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%GENERIC_SUBBLOCK-2-GSBNOTISSUAWARE : GSB [chars] is not ISSU aware. Cannot distribute it to ISSU-aware slots
Explanation

This GSB is expected to be ISSU aware but it is not. It cannot be distributed safely to ISSU-aware slots as it may not be
correctly interpreted
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

GEN_DB

%GEN_DB-3-NULL_TREE_NODE : Node is NULL [chars]
Explanation

This message indicates that the tree node being examined is NULL
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%GEN_DB-3-INVALID_RECORD_KEY : [chars]: invalid record key *
Explanation

This message indicates that the record key is invalid
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%GEN_DB-3-NO_KEY_FUNC : [chars]: [chars][chars]
Explanation

This message indicates that key functions are missing from the database handle, or key function is a NULL Pointer
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%GEN_DB-3-KEY_FUNC_DOESNT_EXIST : [chars]: Key function does not exist
Explanation

This message indicates that key function being considered does not exist in the database definition
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%GEN_DB-3-INVALID_CLIENT_TYPE : [chars]: Invalid client type, got [dec] (must be between 0 and [dec])
Explanation

This message indicates that client type is outside the expected range
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%GEN_DB-3-NULL_DB_HNDL : NULL Database Handle [chars]
Explanation

This message indicates the database handle was NULL
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%GEN_DB-3-NULL_DB_HNDL_ELEMENT : [chars]: NULL Database Element [chars]
Explanation

This message indicates the database handle element was NULL
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%GEN_DB-3-LIST_FAIL : [chars]:[chars]
Explanation

This message indicates that a list operations such as enqueue, dequeu failed
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%GEN_DB-3-LIST_FAIL_FOR_RECORD : [chars]:[dec]:[chars]
Explanation

This message indicates that a list operations such as enqueue, dequeu failed
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%GEN_DB-3-WAVL_FAIL : [chars]: [chars]
Explanation

This message indicates that a wavl tree operation failed
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%GEN_DB-3-RECORD_DELETE_FAIL : [chars]:[chars]
Explanation

This message indicates that a record could not be deleted
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%GEN_DB-3-PARSER_INIT_FAIL : [chars]:[dec]: Parser Could not be initialized
Explanation

This message indicates that the IOS Parser command could not be initialized
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%GEN_DB-3-UNKNOWN_PARSER_CMD : [chars]:[dec]: Unknown Parser Command
Explanation

This message indicates that the IOS Parser command was not recognized
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.

GEN_PROXY

%GEN_PROXY-3-IPC_UNHANDLED : failure
Explanation

An unknown message type: %d was received by the Generic Client Proxy.
Recommended Action

LOG_STD_ACTION
%GEN_PROXY-3-REPLY_MSG : wrong version [dec]
Explanation

An incorrect SBS message was received by the Generic Client Proxy.
Recommended Action

LOG_STD_ACTION
%GEN_PROXY-3-STACK_ALLOC_FAILED : Stack allocation for reply failed reply_size [hex]
Explanation

Stack space could not be allocated for reply.
Recommended Action

LOG_STD_ACTION
%GEN_PROXY-3-GPM_ALLOC_FAILED : GPM allocation for reply failed pak_size [hex] reply_size [hex]
Explanation

GPM could not be allocated for reply.
Recommended Action

LOG_STD_ACTION
%GEN_PROXY-3-IPC_SEND_FAILED : IPC send reply failed [chars]
Explanation

GEN proxy failed to send of reply to IPC msg.
Recommended Action

LOG_STD_ACTION

GLBP

%GLBP-4-BADAUTH : Bad authentication received from [chars], group [dec]
Explanation

Two routers participating in a Gateway Load Balancing Protocol group disagree on the valid authentication string.
Recommended Action

Use the glbp authentication interface command to repair the GLBP authentication discrepancy between the local system and the
one whose IP address is reported.
%GLBP-3-MISCONFIG : Cannot add MAC address [enet] to interface [chars] — not supported
Explanation

A software or hardware error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%GLBP-6-STATECHANGE : [chars] Grp [int] state [chars] -> [chars]
Explanation

The GLBP gateway has changed state
Recommended Action

No action is required.
%GLBP-6-FWDSTATECHANGE : [chars] Grp [int] Fwd [int] state [chars] -> [chars]
Explanation

The GLBP forwarder has changed state
Recommended Action

No action is required.
%GLBP-4-DUPADDR : Duplicate address [chars] on [chars], sourced by [enet]
Explanation

The IP address in a GLBP message received on the interface is the same as the router’s own IP address. This may be because
of misconfiugration, or because of a malfunctioning switch
Recommended Action

Check the configurations on all the GLBP routers, and make sure that any switches you have are functioning properly.
%GLBP-4-DUPVIP1 : [chars] Grp [dec] address [chars] is already assigned to [chars] group [dec]
Explanation

The GLBP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to a different GLBP
group.
Recommended Action

Check the configuration on all GLBP routers.
%GLBP-4-DUPVIP2 : [chars] Grp [dec] address [chars] is already assigned on this interface
Explanation

The GLBP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to this interface.
Recommended Action

Check the configuration on all GLBP routers.
%GLBP-4-DUPVIP3 : [chars] Grp [dec] address [chars] is already assigned to, or overlaps with, an address on another interface
or application
Explanation

The GLBP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to, or overlaps with,
an address on another interface or application.
Recommended Action

Check the configuration on all GLBP routers.
%GLBP-4-BADVIP : [chars] Grp [dec] address [chars] is in the wrong subnet for this interface
Explanation

The GLBP virtual IP address contained in the Hello message cannot be learnt as it is not within a subnet configured on the
interface.
Recommended Action

Check the configuration on all GLBP routers and ensure that the virtual IP address is within a configured subnet.
%GLBP-4-DIFFVIP1 : [chars] Grp [dec] active routers virtual IP address [chars] is different to the locally configured address
[chars]
Explanation

The GLBP virtual IP address contained in the Hello message from the Active router is different to that configured locally.
Recommended Action

Check the configuration on all GLBP routers.

GRIP

%GRIP-3-BADPATHS : Invalid number of paths ([dec]) for %q
Explanation

An internal inconsistency was detected in the XNS routing table structure.
Recommended Action

Note the parameters associated with this message and call your technical support representative for assistance.
%GRIP-2-BADROUTE : Error [chars] route — null table
Explanation

A hardware or software error occurred.
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.

HA

%HA-6-TOOBIG : Running config too big, config sync failed
Explanation

The running config was too big to be synced
Recommended Action

No action is required.
%HA-6-SWITCHOVER : Route Processor switched from standby to being active
Explanation

This RP switched to become the active RP
Recommended Action

No action is required.

HAL_GENMEM

%HAL_GENMEM-3-HAL_MISMATCHED_GENMEM : VADDR:[int] LINE: [dec]
Explanation

Mismatched genmem.
Recommended Action

LOG_STD_ACTION

HAL_PACKET through HTSP

  • HAL_PACKET

  • HA_EM

  • HA_PROXY

  • HDLC

  • HFSLIB

  • HMAN

  • HMAN_CPU

  • HPI

  • HSRP

  • HTSP

HAL_PACKET

%HAL_PACKET-3-HAL_GATHER_ASYNC_WAIT_TIMEOUT : seqnum=[int] pak-type=[int]
Explanation

Packet Hardware Transmit Error
Recommended Action

LOG_STD_ACTION

HA_EM

%HA_EM-7-FMCMN_PTHREAD_MUTEX_LOCK : [chars]: Error locking mutex [chars]; [chars]
Explanation

The pthread_mutex_lock function reported an error while attempting to lock the specified mutex.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMCMN_PTHREAD_MUTEX_UNLOCK : [chars]: Error unlocking mutex [chars]; [chars]
Explanation

The pthread_mutex_unlock function reported an error while attempting to unlock the specified mutex.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFDCMN_DM_CREATE : [chars]: could not create dispatch manager: [chars]
Explanation

The event detector has failed to create an dispatch manager.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFDCMN_EA_ATTACH : [chars]: could not register for asynchronous message events: [chars]
Explanation

The event detector has failed to attach an event handler for asynchronous messages.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFDCMN_INV_TM : [chars]: invalid timer: type=[dec], timer=[IPV6 address]
Explanation

Internal error. The timer value is invalid or not as expected.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFDCMN_INV_TM_TYPE : [chars]: invalid timer type: [dec]
Explanation

Internal error. The timer type is invalid or not supported.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFDCMN_MSGSEND_EVT : [chars]: error returned from event_send_pulse; [chars]
Explanation

The event detector has failed to send a pulse to itself to notify of a pending message send event.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFDCMN_PUB_RBLD : [chars]: [chars]
Explanation

Internal error. The event detector has failed to rebuild the publish list from the checkpointed records.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFDCMN_XDM_DISPATCH_FAIL : [chars]: XOS Dispatch Manager dispatch error: [dec]
Explanation

XOS Dispatch Manager reports an error when dispatching an event.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFDCMN_XDM_WAIT_FAIL : [chars]: XOS Dispatch Manager wait error: [dec]
Explanation

XOS Dispatch Manager reports an error when waiting for an event.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_ADD_PARSER : [chars]: Unable to add [chars] event detector command;
Explanation

The Event detector failed to add command.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_CHKPT_INIT : [chars]: [chars]
Explanation

Internal error. The event detector has failed to initialize with the checkpointing server.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_CHKPT_TBL_ADD : [chars]: [chars]
Explanation

Internal error. The event detector has failed to add a record to the checkpointing table.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_CHKPT_TBL_INIT : [chars]: [chars]
Explanation

Internal error. The event detector has failed to initialize a table with the checkpointing server.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_CHKPT_TBL_ITERATE : [chars]: [chars]
Explanation

Internal error. The event detector has failed to iterate the checkpointing table.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_CHKPT_TBL_REMOVE : [chars]: [chars]
Explanation

Internal error. The event detector has failed to remove a record from the checkpointing table.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_COND_WAIT : [chars]: conditional wait error: [chars]
Explanation

Internal error. The event detector has failed to do pthread conditional wait.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_CONNECTION_FAIL : Could not connect to [chars] : [chars]
Explanation

Could not connect to event detector on the remote node. Node may be invalid or not available or the process may not be available
to accept the connection.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_DE_FETCH : [chars]: [chars][[dec]]
Explanation

Internal error. The event detector has failed to fetch a data elementfrom the statistics data engine.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_DE_INIT : [chars]: [chars]
Explanation

Internal error. The event detector has failed to initialize the statistics data engine.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_DM_CREATE : [chars]: could not create dispatch manager: [chars]
Explanation

The event detector has failed to create an dispatch manager.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_EA_ATTACH : [chars]: could not register for asynchronous message events: [chars]
Explanation

The event detector has failed to attach an event handler for asynchronous messages.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMFD_EMPTY_QUEUE : [chars]: The [chars] event detector I/O queue empty.
Explanation

The I/O queue is empty at this point, and should not be.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_ENQUEUE_FAIL : [chars]: Unable to enqueue [chars];
Explanation

The enqueue function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_EV_BLOCK : [chars]: [chars]
Explanation

The event_block function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_EVM_CREATE : Could not create event manager: [chars]
Explanation

The event detector has failed to create an Event Manager.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_HIST_QERR : [chars]
Explanation

Internal error. The event detector has failed to get a free history listentry.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_HIST_RBLD : [chars]: [chars]
Explanation

Internal error. The event detector has failed to rebuild the history list from the checkpointed records.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_INV_COMPARE_OP : [chars]: invalid comparison operator: [dec]
Explanation

Internal error. The value comparison operator is invalid or notsupported.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_INV_STATS_TYPE : [chars]: invalid statistics value type: [dec]
Explanation

Internal error. The statistics data type is invalid or not supported.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_INV_TM : [chars]: invalid timer: type=[dec], timer=[IPV6 address]
Explanation

Internal error. The timer value is invalid or not as expected.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_INV_TM_TYPE : [chars]: invalid timer type: [dec]
Explanation

Internal error. The timer type is invalid or not supported.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_LOCAL_NODEID : Could not get local nodeid: [chars]
Explanation

Could not get local node identifier.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_MALLOC : [chars]: Unable to allocate [chars]; [chars]
Explanation

The malloc function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_MET_ENQUEUE : [chars]: could not enqueue metric data: [chars]
Explanation

Internal error. The system manager event detector has failed to add a metric data entry to the list.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_MET_RBLD : [chars]: [chars]
Explanation

Internal error. The event detector has failed to rebuild the metriclist from the checkpointed records.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_MISC_ERR : [chars]: [chars]
Explanation

An unexpected error occurred.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_MSGSEND_EVT : [chars]: error returned from event_send_pulse; [chars]
Explanation

The event detector has failed to send a pulse to itself to notify of a pending message send event.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_MSGSEND_RETRY_ERR : [chars]: [dec]
Explanation

The event detector has exceeded its maximum number of retries to send apulse to the embedded event manager to notify of an
event publish.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_NO_CLOCK : [chars]: unable to read clock using clock_gettime: [chars]
Explanation

The clock_gettime function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_NO_MEM : [chars]: not enough memory: [chars]
Explanation

Allocating memory failed due to a low-memory condition.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_OE_CREATE : [chars]: could not create an occurrence entry
Explanation

Internal error. The event detector has failed to create an entry for thematched occurrence list.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_OE_REMOVE : [chars]: could not remove an occurrence entry
Explanation

Internal error. The event detector has failed to remove an entry for thematched occurrence list.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMFD_OID_UNAVAIL : [chars]: The following oid has become unavailable: [chars]
Explanation

The registered oid is no longer available in the system.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_OPEN_CONF : [chars]: could not open event detector config file: [chars]
Explanation

The event detector has failed to open the config file for event detector type information.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_PTHRD_CREATE : [chars]: could not create a Posix thread
Explanation

The pthread_create function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_PUB_RBLD : [chars]: [chars]
Explanation

Internal error. The event detector has failed to rebuild the publish list from the checkpointed records.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_PUB_TM_ALLOC : [chars]: Unable to allocate memory for event publish timer block
Explanation

Internal error. The event detector has failed to allocate memoryfor the event publish timer block.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMFD_QUEUE_INIT : [chars]: Unable to initialize queue;
Explanation

The queue initialization function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_RESOURCE_MONITOR_REGISTER_FAIL : [chars]: resource_monitor_register failed; return code = [dec]
Explanation

The resource_monitor_register function reported an error trying toregister for RMI notifications.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_RM_ATTACH : [chars]: could not attach resource manager funtions to event manager: [chars]
Explanation

The event detector has failed to attach a Resource Manager to an Event Manager.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SM_PROC_EXIT : [chars]: [chars]
Explanation

The system manager failed to execute the default action of the terminated process.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SNMP_ADDR_ILLEGAL : [chars]: Illegal SNMP address type
Explanation

The SNMP address is illegal.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SNMP_ADDR_IPV6 : [chars]: SNMP IPV6 address is not supported
Explanation

The IPV6 address is not supported.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SNMP_BUILD_PDU_FAILED : [chars]: SNMP build pdu failed
Explanation

The SNMP pdu build has failed.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SNMP_COMM_FAIL : [chars]: Unable to create SNMP octet community string; string = [chars]
Explanation

The community string was not able to build into a SNMP octet string
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SNMP_COMMUNICATE_FAIL : [chars]: [chars] [chars]
Explanation

Unable to communicate with SNMPD process
Recommended Action

Check whether SNMP is configured on this Router.
%HA_EM-7-FMFD_SNMP_ERRCODE : [chars]: [chars]
Explanation

The SNMP error code.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SNMP_MAKE_PDU_FAILED : [chars]: SNMP make pdu failed
Explanation

The SNMP pdu make has failed.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMFD_SNMP_MIB_OBJ_REP_FAIL : [chars]: SNMP MIB object info replace failed [dec]
Explanation

The SNMP MIB object info replace function has failed.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SNMP_MSG_FAIL : [chars]: Unable to create a SNMP message; community = [chars]
Explanation

The SNMP message failed to be created
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-4-FMFD_SNMP_NO_OBJECT_VALUE : [chars]: SNMP MIB object value not provided
Explanation

The SNMP MIB object value is not provided for substitution.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMFD_SNMP_OBJECT_UNKNOWN_RESPONSE_CODE : [chars]: Unknown SNMP object response code [dec]
Explanation

The SNMP MIB object response code is unknown.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SNMP_OID_INVALID : [chars]: Invalid SNMP oid length [dec]
Explanation

The SNMP oid has invalid length
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SNMP_OID_MAKE_FAIL : [chars]: Unable to build an oid string into a SNMP oid; oid = [chars]
Explanation

The oid string was not able to build into a SNMP oid
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SNMP_REQ_FAILED : [chars]: SNMP request failed
Explanation

The SNMP request has failed.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SNMP_RESP_CANCEL : [chars]: SNMP response cancelled
Explanation

The SNMP response has been cancelled.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SNMP_RESP_ERROR : [chars]: SNMP response error; error_status = [dec]
Explanation

The SNMP response has error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SNMP_RESP_Q_EMPTY : [chars]: SNMP proxy exec got event, but queue is empty
Explanation

The SNMP proxy got event but the queue is empty.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SNMP_RESP_TIMEOUT : [chars]: SNMP response has timed out
Explanation

The SNMP response has timed out.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SNMP_UNKNOWN_TYPE : [chars]: Unknown SNMP operation or response type [dec]
Explanation

The operation or response type is unknown.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SNMP_VARBIND_FAIL : [chars]: Unable to create a SNMP varbind
Explanation

The oid failed to make into a SNMP varbind
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_STATS_VAL_GET_ERR : [chars]: [chars]
Explanation

Internal error. The event detector has failed retrieving a valid statistics value.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SYSDB_BIND : [chars]: [chars]
Explanation

Failed to bind to SysDB.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SYSDB_GET : [chars]: [chars]
Explanation

Failed to retrieve an item from SysDB.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_SYSDB_REG_NOTIFY : [chars]: [chars]
Explanation

Failed to register for notification of a set of items in SysDB.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_TM_CRTICK_INIT : [chars]: [chars]
Explanation

Internal error. The initialization of the cron-tick function has failed.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_TM_LEAF_NEW : [chars]: could not create a leaf timer
Explanation

Internal error. The event detector has failed to create a managedleaf timer.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMFD_TTY_NUM : [chars]: Error occurred while fetching TTY number.
Explanation

The Embedded Event Manager failed to fetch a TTY number.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_XDM_DISPATCH_FAIL : [chars]: XOS Dispatch Manager dispatch error: [dec]
Explanation

XOS Dispatch Manager reports an error when dispatching an event.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMFD_XDM_WAIT_FAIL : [chars]: XOS Dispatch Manager wait error: [dec]
Explanation

XOS Dispatch Manager reports an error when waiting for an event.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMC_APPL_CBH_PULSE : [chars]: Unable to locate application publish callback entry for pulse code [dec]
Explanation

The application publish callback handler was unable to validate the pulse code received.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMC_APPL_CBH_SEND : [chars]: Unable to send response for FH_MSG_CALLBACK_DONE [chars]
Explanation

The registration callback handler was unable to send the FH_MSG_CALLBACK_DONE message to the Embedded Event Manager Server.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMC_CB_CLOSE : [chars]: fh_close failed [chars]
Explanation

The fh_close function reported an error trying to initialize the internal callback connection.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMC_CB_EV_CREATE : [chars]: event_manager_create failed [chars]
Explanation

The event_manager_create function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMC_CBH_PROCESS_CREATE : [chars]: callback handler process create failed for eid: [dec]
Explanation

The process_create function reported an error trying to create thecallback handler process.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMC_CB_INIT : [chars]:[dec] (thread:[dec]) fh_init failed [chars]
Explanation

The fh_init function reported an error trying to initialize the internal callback connection.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMC_CBS_PT_CREATE : [chars]: pthread_create failed [chars]
Explanation

The pthread_create function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMC_ENQUEUE_FAIL : [chars]: Unable to enqueue [chars];
Explanation

The enqueue function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMC_FH_INIT : [chars]: fh_init failed : [dec]
Explanation

The fh_init function reported an error trying to initialize EEM fora callback process.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMC_INV_REPLY : [chars]: Application client library unable to handle message receive.
Explanation

The API received a msg reply when it was not in a state to acceptsuch messages.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMC_MALLOC : [chars]: Unable to allocate [chars];
Explanation

The malloc function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMC_REG_CBH_PULSE : [chars]: Unable to locate reg callback entry for pulse code [dec]
Explanation

The registration callback handler was unable to validate the pulse codereceived.
Recommended Action

The pthread_create function reported an error.
%HA_EM-7-FMC_REG_CBH_SEND : [chars]: Unable to send response for FH_MSG_CALLBACK_DONE [chars] [dec]
Explanation

The registration callback handler was unable to send theFH_MSG_CALLBACK_DONE message to the Embedded Event Manager Server.
Recommended Action

The pthread_create function reported an error.
%HA_EM-7-FMC_XDM_DISPATCH_FAIL : [chars]: XOS Dispatch Manager dispatch error: [dec]
Explanation

XOS Dispatch Manager reports an error when dispatching an event.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMC_XDM_WAIT_FAIL : [chars]: XOS Dispatch Manager wait error: [dec]
Explanation

XOS Dispatch Manager reports an error when waiting for an event.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_ACTION : [chars]: Error occurred while performing action: [chars].
Explanation

The Embedded Event Manager Policy Director failed to perform anaction for the registered event.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_ACTION_INFO : [chars]: Error occurred while fetching action information: [dec].
Explanation

The Embedded Event Manager Policy Director failed to gather actioninformation registered for the event.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_ACTION_NOTRACK : [chars]: unable to set state for tracking object number [int]; object does not exist or is
not a stub-object.
Explanation

The Embedded Event Manager applet attempted to set the state ofa tracking object that does not exist.
Recommended Action

Only set the state of tracking objects that have already been configured in the system. If the message continues to occur,
copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_CHECKSUM_MISMATCH : [chars]: file checksum mismatch
Explanation

The checksum value of an installed policy does not match the valueprovided by the installation manager.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_CHKPT_INIT : [chars]: could not register the application with the checkpointing server: [chars]
Explanation

Failed to register an application with the checkpointing server.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_CHKPT_ITERATE_END : [chars]: call to chkpt_iterate_end returned unexpected failure.
Explanation

Failed to register an application with the checkpointing server.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_CHKPT_NULL_PTR : [chars]: Got a null [chars] but non-null value was expected
Explanation

Failed to do further processing because we got a null data when a non-null value was expected.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_CHKPT_TBL_ADD : [chars]: could not save a record into a checkpointing table: [chars]
Explanation

Failed to save a record into the given checkpointing table.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_CHKPT_TBL_INFO_READ : [chars]: could not read the existing table information: [chars]
Explanation

Failed to read the existing table information using checkpointing API.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_CHKPT_TBL_INIT : [chars]: failed to initialize [chars]: [chars]
Explanation

Could not initialize a table with the checkpointing server.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_CHKPT_TBL_RECOVER : [chars]: could not recover the checkpointed [chars]: [chars]
Explanation

Failed to recover a checkpointed table.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_CHKPT_TBL_REMOVE : [chars]: could not delete a record from a checkpointing table: [chars]
Explanation

Failed to delete a record from the given checkpointing table.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_CHKPT_TBL_RESET : [chars]: could not reset a record in a checkpointing table: [chars]
Explanation

Failed to reset a record in the given checkpointing table.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_CLI_CONNECT : Unable to establish CLI session: [chars]
Explanation

Unable to establish CLI session.
Recommended Action

%HA_EM-3-FMPD_CLI_DISCONNECT : Error disconnecting from CLI session: [chars]
Explanation

An error occurred while disconnecting from the CLI session.
Recommended Action

%HA_EM-3-FMPD_CLI_NOTTY : Error attempting to access an unopened CLI session: [chars]
Explanation

An error occurred attempting to access an unopened CLI session: %s
Recommended Action

%HA_EM-3-FMPD_CLI_READ : Unable to read CLI response: [chars]
Explanation

Unable to read CLI response.
Recommended Action

%HA_EM-3-FMPD_CLI_WRITE : Unable to send CLI command: [chars]
Explanation

Unable to send CLI command.
Recommended Action

%HA_EM-6-FMPD_CONTEXT_RETRIEVE : Failed to retrieve context for key [chars]: [chars]
Explanation

Failed to context retrieve variable information for event.
Recommended Action

Ensure context information with the given key is saved. If the message continues to occur, copy the message exactly as it
appears, and report it your technical support representative.
%HA_EM-6-FMPD_CONTEXT_SAVE : Failed to save variable context for key [chars]: [chars]
Explanation

Failed to context save variable information for event.
Recommended Action

Ensure context information with the same key is not already saved. If the message continues to occur, copy the message exactly
as it appears, and report it your technical support representative.
%HA_EM-4-FMPD_DIRECTORY_NOT_EXIST : User policy directory [chars] could not be found on [chars]
Explanation

A policy directory could not be found. Cold start on this location may result in startup configuration failure.
Recommended Action

Create the directory on this location.
%HA_EM-6-FMPD_DIVIDE_ZERO : Invalid operand in arithmetic division, cannot divide by zero
Explanation

Arithmetic division does not allow divide by zero.
Recommended Action

Ensure denominator provided to division action is non-zero.
%HA_EM-4-FMPD_DSIG_TYPE_CHANGE : Cisco Signature not found or invalid. [chars] has been registered as a user policy.
Explanation

Cisco Signature not found or invalid.
Recommended Action

Sign with Cisco signature.
%HA_EM-6-FMPD_EEM_CONFIG : [chars]: [chars]
Explanation

The Embedded Event Manager reports an error on Event Managerconfiguration
Recommended Action

Check the EEM applet or policy configuration
%HA_EM-6-FMPD_EEM_LOG_MSG : [chars]
Explanation

The Embedded Event Manager reports errors when registering a TCL policy.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_ERROR : Error executing applet [chars] statement [chars]
Explanation

The Embedded Event Manager policy director found an error whenprocessing an applet.
Recommended Action

Check syntax of applet statement. If the message continues to occur, copy the message exactly as it appears, and report it
your technical support representative.
%HA_EM-4-FMPD_EVENT_CREATE : [chars]: failed to create an event: [chars]
Explanation

Failed to create an Embedded Event Manager event.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-4-FMPD_EVENT_REG : [chars]: failed to register an event: [chars]
Explanation

Failed to register an Embedded Event Manager event.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_EVENT_TYPE : [chars]: unknown event type [dec]
Explanation

An unknown Embedded Event Manager even type was detected.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_EVM_CREATE : [chars]: could not create event manager: [chars]
Explanation

An internal error was detected when creating Event Manager.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_EVM_EVENT_BLOCK : [chars]: failed to block waiting for Event Manager events: [chars]
Explanation

An internal error was detected when block waiting for Event Manager events.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_EXECUTE_CALLBACK : [chars]: failed to execute callback
Explanation

Failed to execute callback routine.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_FH_INIT : [chars]: could not initialize Embedded Event Manager service: [chars]
Explanation

An internal error was detected when initializing Embedded Event Managerservice.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_FILE_CLOSE : [chars]: failed to close fd [chars] : [chars]
Explanation

Failed to close the given file descriptor due to some internal error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_FILE_DELETE : [chars]: failed to delete file: [chars] : [chars]
Explanation

Failed to delete the given file.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_FILE_OPEN : [chars]: failed to open file [chars] : [chars]
Explanation

Failed to open the given file due to some internal error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_FILE_READ : [chars]: failed to read from fd [chars] : [chars]
Explanation

Failed to read from the given file descriptor due to some internal error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_FILE_WRITE : [chars]: failed to write to fd [chars] : [chars]
Explanation

Failed to write to the given file descriptor due to some internal error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_FORMAT_TIME : [chars]: error attemting to format time string
Explanation

Format time failure.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_GET_PRIO : [chars]: failed to get process priority: [chars]
Explanation

Internal error. A call to get process scheduling priority failed.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-4-FMPD_IPC_GET_PAK : [chars]: failed to allocate an IPC buffer
Explanation

Embedded Event Manager failed to allocate a buffer from IPC.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_IPC_PORT_CREATE : [chars]: failed to create an IPC port: [chars]
Explanation

Embedded Event Manager failed to create an IPC port.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_IPC_PORT_OPEN : [chars]: failed to open an IPC port: [chars]
Explanation

Embedded Event Manager failed to open an IPC port.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_IPC_PORT_REGISTER : [chars]: failed to register an IPC port: [chars]
Explanation

Embedded Event Manager failed to register an IPC port.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-4-FMPD_IPC_SEND_MSG : [chars]: failed to send an IPC message: [chars]
Explanation

Embedded Event Manager failed to send a message through IPC.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_LAST_POLICY : [chars]: invalid last policy name replied [chars]
Explanation

Internal error. The last policy name the script director repliedto show fm policy registered command is an invalid policy
name.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_MEM_ALLOC : Not enough memory ([dec] bytes)
Explanation

Allocating memory failed due to a low-memory condition.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-4-FMPD_NO_ACTION : No action configured for applet [chars]
Explanation

No action has been configured for this applet.
Recommended Action

Configure at least one action for this applet.
%HA_EM-7-FMPD_NO_CLOCK : [chars]: unable to read clock using clock_gettime: [chars]
Explanation

The clock_gettime function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_NOEID : [chars]: No such event id found.
Explanation

An internal software error occurred.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_NOESID : [chars]: No such event spec id found.
Explanation

The Embedded Event Manager Policy Director could not find the eventfor the event spec. ID.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-4-FMPD_NO_EVENT : No event configured for applet [chars]
Explanation

No event has been configured for this applet.
Recommended Action

Configure an event for this applet.
%HA_EM-7-FMPD_NO_MEM : [chars]: not enough memory: [chars]
Explanation

Allocating memory failed due to a low-memory condition.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_NO_PROC : [chars]: Failed to create process
Explanation

The process create function reports an error
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-4-FMPD_NOTAGNAME : [chars]: No tag [chars] found corresponding to this event publish.
Explanation

The Embedded Event Manager policy director could not associate the tagname with a published event.
Recommended Action

Only use tagnames in the action info type event reqinfo command which correspond to the published event.
%HA_EM-6-FMPD_OPERAND_INVALID : Invalid operand in action, expected value within range %ld to %ld, received: [chars]
Explanation

Arithmetic actions only accept valid long integer values.
Recommended Action

Ensure value provided to action is long integer.
%HA_EM-3-FMPD_OVL_NOTIF_REG : [chars]: could not register for Version Manager notification: [chars]
Explanation

An internal error was detected when registering for Version Manager notification.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_OVL_SETUP_ENV : [chars]: [chars]
Explanation

Updating environment variables of the process according to system variables stored in sysdb failed.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-4-FMPD_POLICY_APPLY : Could not apply policy ‘[chars]’: [chars]
Explanation

A policy could not be applied. This message signaled an unsuccessful apply of the policy.
Recommended Action

Remove the configuration for the policy (and commit), and then attempt to configure the registration of the same policy.
%HA_EM-6-FMPD_POLICY_CHANGED : [chars]: registered policy [chars] changed by the last installation update
Explanation

A registered policy was changed by the last installation update. If the update used the start option, the old policy was automatically
unregistered and the new policy registered. Otherwise, the old policy would remain registered and functional until the user
unregisters it manually.
Recommended Action

None.
%HA_EM-4-FMPD_POLICY_CONFIG_INCONSISTENT : Policy ‘[chars]’: [chars]
Explanation

Some policy configuration is potentially inconsistent, and the user should follow the guidelines in the message to amend this.
Recommended Action

Examine the guidelines in the message, and the event manager configuration,to determine the potential problem. Note that this
is just a warning message, not an error message, as the configuration is legal — it may be the case that the user has intentionally
set this configuration.
%HA_EM-6-FMPD_POLICY_DELETED : [chars]: registered policy [chars] deleted by the last installation update
Explanation

A registered policy was deleted by the last installation update. If the update used the start option, the policy was automatically
unregistered. Otherwise, the policy would remain registered and functional until the user unregisters it manually.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_POLICY_HASH : [chars]: The hash computation routine reported an error; [chars]
Explanation

The policy dir checksum function reported the specified error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-4-FMPD_POLICY_NOT_EXIST : Policy file [chars] could not be found on [chars]
Explanation

A policy file could not be found. Cold start on this location may result in startup
Recommended Action

Copy the policy file to this location.
%HA_EM-6-FMPD_POLICY_REG_SUCC : [chars]: Policy ‘[chars]’ registered successfully, by user [chars], with persist time [dec]
and type [dec]
Explanation

A new policy has been registered with Embedded Event Manager. This message signaled a successful registration.
Recommended Action

None.
%HA_EM-7-FMPD_POLICY_TBL_REMOVE : [chars]: could not delete a record from a checkpointing table: [chars]
Explanation

Failed to delete a record from the given checkpointing table.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-4-FMPD_POLICY_TUPLE_UNPACK : Failed to unpack_tuple to get username (Err: [dec]) for [chars]
Explanation

Failed to unpack sysdb tuple to get the username for the scripts.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_POLICY_UNREG_ERR : [chars]: could not unregister policy [chars]: [chars]
Explanation

A registered policy changed or deleted by the last installation update was detected. Since the update used the start option,
the old policy was automatically unregistered. This message signaled an unsuccessful unregistration.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_POLICY_UNREGREG_ERR : [chars]: could not replace policy [chars]: [chars]
Explanation

A registered policy changed by the last installation update was detected. Since the update used the start option, the old
policy was automatically replaced by the new policy. This message signaled an unsuccessful replacement of the policy.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-6-FMPD_POLICY_UNREGREG_SUCC : [chars]: policy [chars] replaced successfully
Explanation

A registered policy changed by the last installation update was detected. Since the update used the start option, the old
policy was automatically replaced by the new policy. This message signaled a successful replacement of the policy.
Recommended Action

None.
%HA_EM-6-FMPD_POLICY_UNREG_SUCC : [chars]: policy [chars] unregistered successfully
Explanation

A registered policy changed or deleted by the last installation update was detected. Since the update used the start option,
the old policy was automatically unregistered. This message signaled a successful unregistration.
Recommended Action

None.
%HA_EM-3-FMPD_PROCESS_XML : [chars]: error processing xml buffer
Explanation

An error occurred processing the event publish information xml buffer.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_QUEUE_INIT : [chars]: could not initialize queue
Explanation

An internal error was detected when initializing Embedded Event Managerqueue.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_REFRESHTIMER_INIT : Failed to initialize a refresh timer ([chars]): [chars]
Explanation

Failed to initialize a Embedded Event Manager refresh timer.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-6-FMPD_REGCOMP : Error compiling regular expression: [chars]
Explanation

An error was encountered when compiling the given regular expression.
Recommended Action

Check syntax of regular expression pattern. If the message continues to occur, copy the message exactly as it appears, and
report it your technical support representative.
%HA_EM-3-FMPD_REQINFO : [chars]: Error attempting to fetch event information: [chars].
Explanation

The Embedded Event Manager Policy Director failed to receive event infofor a callback.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_SET_INFO : [chars]: Error occurred while fetching variable information: [dec].
Explanation

The Embedded Event Manager Policy Director was unable to set thevariable with the requested information.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_SHM_OPEN : [chars]: ERROR opening shared mem IDB
Explanation

An internal error was detected when attempting to open the IDB shared memory area
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_SMTP : Error occurred when sending mail to SMTP server: [chars] : [chars]
Explanation

An unexpected error occurred when sending mail to SMTP server.
Recommended Action

%HA_EM-3-FMPD_SMTP_SEND : Unable to send notification using all SMTP servers
Explanation

An unexpected error occurred when sending mail to all SMTP servers.
Recommended Action

%HA_EM-6-FMPD_SNMP_DUP_OID : [chars]: duplicate oid
Explanation

The oid is a duplicate
Recommended Action

Check the EEM applet or policy configuration
%HA_EM-6-FMPD_SNMP_NO_VAR : [chars]: No variable [chars]
Explanation

The variable is not defined.
Recommended Action

Check the EEM applet or policy configuration
%HA_EM-6-FMPD_SNMP_TRAPVAR_ADD : [chars]: Error adding trapvar to queue [chars]
Explanation

The trap variable was not added to the queue.
Recommended Action

Check the EEM applet or policy configuration
%HA_EM-6-FMPD_SNMP_VARS_EXCEEDED : [chars]: number of values exceeded [dec]
Explanation

The number of values per variable exceeded the maximum
Recommended Action

Check the EEM applet or policy configuration
%HA_EM-7-FMPD_SWITCH_FAIL : [chars]: The system is unable to switch to standby processor. Switchover cancelled.
Explanation

Switchovers must occur when STANDBY is available and ready.
Recommended Action

None Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-6-FMPD_SWITCH_HARDWARE : [chars]: Policy has requested a hardware switchover
Explanation

An Embedded Event Manager policy requested that a hardware switchoveroccur.
Recommended Action

None
%HA_EM-7-FMPD_SYSDB_VERIFY_REG : Could not register for SysDB verification: [chars]
Explanation

An internal error was detected when trying to register verify function and/or apply function for SysDB tuple operations upon
the given item within the given namespace.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_THREAD_POOL : [chars]: [chars]
Explanation

An internal error was detected while initialization of threadpool.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_UNKNOWN_ENV : [chars]: could not find environment variable: [chars]
Explanation

The Embedded Event Manager policy director could not find the environmentvariable specified in the action message.
Recommended Action

Only use well known Embedded Event Manager environment variables. If the message continues to occur, copy the message exactly
as it appears, and report it your technical support representative.
%HA_EM-3-FMPD_UNKNOWNTYPE : [chars]: Unknown event type found in applet.
Explanation

The Embedded Event Manager applet had an unknown event type.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-6-FMPD_UPDATE_POLICY_COPY : Policy update has copied [dec] bytes from [chars] to [chars]
Explanation

An EEM policy has been copied as a result of an event manager update command
Recommended Action

%HA_EM-6-FMPD_UPDATE_POLICY_REGISTER : Policy update has successfully re-registered policy [chars]
Explanation

An EEM policy has been successfully re-registered as a result of an event manager update command
Recommended Action

%HA_EM-6-FMPD_UPDATE_POLICY_REGISTER_FAIL : Policy update has failed to register policy [chars] [chars]
Explanation

An EEM policy has failed to be registered as a result of an event manager update command
Recommended Action

%HA_EM-6-FMPD_UPDATE_POLICY_UNREGISTER_FAIL : Policy update has failed to unregister policy [chars] [chars]
Explanation

An EEM policy has failed to be unregistered as a result of an event manager update command
Recommended Action

%HA_EM-3-FMPD_WRONGTYPE : [chars]: Published event type does not match event spec.
Explanation

The Embedded Event Manager Policy Director detected a mis-match in eventtype between the published event and the event spec.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_XDM_DISPATCH_FAIL : [chars]: XOS Dispatch Manager dispatch error: [dec]
Explanation

XOS Dispatch Manager reports an error when dispatching an event.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMPD_XDM_WAIT_FAIL : [chars]: XOS Dispatch Manager wait error: [dec]
Explanation

XOS Dispatch Manager reports an error when waiting for an event.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-ACTION_ADD_PARSER : [chars]: Unable to add action [chars] command;
Explanation

Failed to add action command.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-ACTION_CNS_AGENT_UNAVAIL : [chars]: CNS Event Agent not available: [dec]
Explanation

The CNS Event Agent is currently not available.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-ACTION_CNS_CLEAR_RESTART : [chars]: Unable to clear restart callback;
Explanation

The CNS Action process failed to clear restart callback.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-ACTION_CNS_OPEN_FAIL : [chars]: Unable to open connection to CNS Event Agent: [dec]
Explanation

The CNS Action process failed to open CNS handle to Event Agent.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-ACTION_CNS_SET_RESTART : [chars]: Unable to set restart callback;
Explanation

The CNS Action process failed to set the restart callback.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-ACTION_ENQUEUE_FAIL : [chars]: Unable to enqueue [chars];
Explanation

The enqueue function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-ACTION_WB_CREATE : [chars]: create_watched_boolean failed: [chars]
Explanation

The create_watched_boolean function reported an error trying to createthe watched boolean.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-ACTION_WB_DELETE : [chars]: delete_watched_boolean failed: [chars]
Explanation

The delete_watched_boolean function reported an error trying to delete the watched boolean.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_ASYNC_ATTACH_CHKPT : [chars]: Failed to attach to handle chkpt asynchronous events; [chars]
Explanation

The event_pulse_attach_event function reported an error trying to attach the chkpt pulse handler.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_ASYNC_ATTACH_DEFAULT : [chars]: Failed to attach to handle default asychronous events; [chars]
Explanation

The event_pulse_attach_event function reported an error trying to attach the default pulse handler.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_CHKPT_INIT : [chars]: could not register the application with the checkpointing server: [chars]
Explanation

Failed to register an application with the checkpointing server.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_CHKPT_ITERATE_END : [chars]: call to chkpt_iterate_end returned unexpected failure.
Explanation

Unexpected error when iterating over a checkpointing table.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_CHKPT_NULL_PTR : [chars]: Got a null [chars] when non-null value was expected
Explanation

Failed to do further processing because we got a null data when a non-null value was expected.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_CHKPT_TBL_ADD : [chars]: could not add to the checkpointed [chars]: [chars]
Explanation

Failed to add a record to the checkpointed table.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_CHKPT_TBL_INFO_READ : [chars]: could not read the existing table information: [chars]
Explanation

Failed to read the existing table information using checkpointing API.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_CHKPT_TBL_INIT : [chars]: failed to initialize [chars]: [chars]
Explanation

Could not initialize a table with the checkpointing server.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_CHKPT_TBL_RECOVER : [chars]: could not recover for the checkpointed [chars]: [chars]
Explanation

Failed to recover a record from the checkpointed table.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_CHKPT_TBL_REMOVE : [chars]: could not remove from the checkpointed [chars]: [chars]
Explanation

Failed to remove a record from a checkpointed table.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_CHKPT_TBL_SAVE : [chars]: could not save to the checkpointed [chars]: [chars]
Explanation

Failed to save a record to a checkpointed table.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_CHKPT_TBL_UNREG : [chars]: could not unregister the checkpointed table [chars]: [chars]
Explanation

Failed to unregister a checkpointed table.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMS_CNS_FAIL : [chars]: Failed to perform CNS action: [chars]
Explanation

The Embedded Event Manager failed attempting to send a CNS message.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_CREATE_THREAD_POOL : [chars]: Error reported by create_thread_pool function; [chars]
Explanation

The create_thread_pool function reported an error while attempting to create the thread pool.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMS_EMPTY_QUEUE : [chars]: The I/O queue empty.
Explanation

The I/O queue is empty at this point, and should not be.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMS_ENQUEUE_FAIL : [chars]: The Unable to enqueue packet onto queue.
Explanation

The queue is not in a state to handle enqueues.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_EVM_CREATE : [chars]: event_manager_create failed; [chars]
Explanation

The event_manager_create function reported an error trying to initialize the event manager.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_EVM_EVENT_BLOCK : An error occurred while waiting for an event: [chars]
Explanation

The event infrastructure will ignore this error and continue to wait for the next event. If this error is seen repeatedly,
the process may not be able to function and will need to be restarted.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_FDC_ALLOCATE : [chars]: Failed to allocate Event Detector context control block; [chars]
Explanation

The get_fd function reported an error trying to allocate a Event Detectorcontext control block.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_FDC_OPEN : [chars]: Failed to open Event Detector context control block
Explanation

The open_fd function reported an error trying to open a Event Detectorcontext control block.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_GET_NODE_NAME : [chars]: platform_get_node_name failed; [chars]
Explanation

The platform_get_node_name function reported an error trying to obtain the node name.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_GET_NODE_STATE : Failed to get the current nodes state: [chars]
Explanation

The call to get the nodes current state failed.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_GET_PRIO : [chars]: Failed to get process priority; [chars]
Explanation

The getprio function reported an error trying to obtain the default process priority.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_GUARD_WORD_VER : [chars]: [chars] guard word corrupted; [IPV6 address]
Explanation

The guard word for the specified control block does not contain what isexpected.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_INV_ARG_STRING : [chars]: Invalid argument string: [chars]
Explanation

An invalid argument string was passed to the specified function.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_INV_ENV_STRING : [chars]: Invalid environment string: [chars]
Explanation

An invalid environment string was passed to the specified function.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_KILL : [chars]: Unable to kill process [chars]; [chars]
Explanation

The kill function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_KILL_RUN : [chars]: Unable to kill run process [dec] for [chars]; [chars]
Explanation

The kill function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-6-FMS_LAST_POLICY : [chars]: Cannot change a class [chars] [chars] to priority LAST. LAST is for default policies
only
Explanation

Embedded Event Manager Scheduler Command can only change a default policy to priority LAST.
Recommended Action

The command is applicable to default policies only.
%HA_EM-7-FMS_MALLOC : [chars]: Unable to allocate [chars]; [chars]
Explanation

The malloc function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_MISC_ERR : [chars] ([chars])
Explanation

An unexpected error occurred.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-6-FMS_MODIFY_LAST_POLICY : [chars]: Cannot modify a LAST policy to class [chars]. LAST policies are for class default
only.
Explanation

Embedded Event Manager LAST policy is for default class only.
Recommended Action

The command is applicable to default policies only.
%HA_EM-6-FMS_MODIFY_POLICY : [chars]: unable to modify the policy to class [chars]: scheduling rule unavailable.
Explanation

There is no scheduler rule configured to service this event class.
Recommended Action

Please configure a scheduler rule before modifying the event.
%HA_EM-7-FMS_NO_CLOCK : [chars]: unable to read clock using clock_gettime: [chars]
Explanation

The clock_gettime function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-4-FMS_NO_SCHED_THREAD : No threads are configured to service event class [chars]
Explanation

The Embedded Event Manager has no scheduler threads to service this event class.
Recommended Action

Track ED is not available in this image Configure threads for the event class using the ‘event manager scheduler’ command.
%HA_EM-3-FMS_NO_TRACK : keyword in the correlate statement is not supported in this image.
Explanation

The Embedded Event Manager Track ED is not supported in this image.
Recommended Action

Track ED is not available in this image
%HA_EM-7-FMS_NULL_SCRIPT_NAME : [chars]: The script name is NULL
Explanation

An invalid script name was passed as an argument into the specifiedfunction.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMS_OPEN : [chars]: Unable to open [chars]; [chars]
Explanation

The open function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_OVL_NOTIFY_REG : [chars]: ovl_notification_register failed when registering to handle OVL notifications; [chars]
Explanation

The ovl_register_notification function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_OVL_SETUP_ENV : [chars]: [chars]
Explanation

Updating environment variables of the process according to system variables stored in sysdb failed.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMS_POLICY_CHECKSUM : [chars]: Checksum error for policy [chars] — this policy will not be run
Explanation

The checksum computed for the specified policy does not match the original checksum computed when the policy was registered.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_POLICY_EXEC : [chars]: Policy execution [chars]
Explanation

The Embedded Event Manager policy excution state has been changed to thestate named in the message.
Recommended Action

%HA_EM-3-FMS_POLICY_HASH : [chars]: The hash computation routine reported an error; [chars]
Explanation

The fh_hash_md5_fd() function reported the specified error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-3-FMS_POLICY_LOOKUP_FAIL : [chars]: Failed to look up in the table the registration specification for policy [chars].
Explanation

A table lookup for the registration specification for the policy failed.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_POLICY_MAX_ENTRIES : [chars]: Class [chars]: Maximum number of [dec] [chars] publish entries exceeded; some
events have been discarded
Explanation

An attempt to publish an event failed because there is no more room in the publish queue
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative
%HA_EM-6-FMS_POLICY_TIMEOUT : Policy ‘[chars]’ has hit its maximum execution time of [dec].%9.9ld seconds, and so has been
halted
Explanation

The policy has exceeded its maximum execution time, and so has been halted part way through execution.If this policy is expected
to take a long time to run, it may need to have ‘maxrun_sec’ added to the policy registration line (or its value increased
if it is already specified).
Recommended Action

*NONE*
%HA_EM-3-FMS_QUEUE_INIT : [chars]: The Unable to initialize queue.
Explanation

The queue cannot be initialized.An attempt to publish an event failed because there is no more roomin the publish queue.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.Copy the message exactly as it
appears, and report it your technical support representative.
%HA_EM-7-FMS_REALLOC_FAIL : [chars]: Unable to reallocate [chars]; [chars]
Explanation

The realloc function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_REG_NODE_STATE_CHANGE : Failed to register for node state changes: [chars]
Explanation

The call to register for node state changes failed.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-6-FMS_RELOAD_SYSTEM : [chars]: Policy has requested a system reload;
Explanation

An Embedded Event Manager policy requested that the system be reloaded.
Recommended Action

%HA_EM-6-FMS_RUNNING_POLICY : [chars]: cannot [chars] a running policy with jobid [dec].
Explanation

Embedded Event Manager Scheduler Command cannot change a running policy.
Recommended Action

The command is not applicable to a running policy.
%HA_EM-7-FMS_SPAWN : [chars]: Unable to spawn [chars]; [chars]
Explanation

The spawn function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_STRDUP : [chars]: Failed to duplicate string [chars]; [chars]
Explanation

The strdup function reported an error.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_SWITCH_FAIL : [chars]: The system is unable to switch to standby processor. Switchover cancelled.
Explanation

Switchovers must occur when STANDBY is available and ready.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-6-FMS_SWITCH_HARDWARE : [chars]: Policy has requested a hardware switchover
Explanation

An Embedded Event Manager policy requested that a hardware switchoveroccur.
Recommended Action

%HA_EM-3-FMS_SWITCH_NOT_RF_ACTIVE : [chars]: This processor is not in ACTIVE state (state = [dec]). Switchover must be performed
on ACTIVE processor.
Explanation

Switchovers must occur on ACTIVE unit, not STANDBY unit.
Recommended Action

%HA_EM-7-FMS_SYSLOG_SCAN_RESIGN : [chars]: Failed to unload Syslog FD DLL [chars]; return code=[dec]
Explanation

The syslog_scan_resign function reported an error trying to unload the specified Syslog Event Detector DLL library.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_SYSLOG_SCAN_SIGNUP : [chars]: Failed to load Syslog FD DLL [chars]; return code=[dec]
Explanation

The syslog_scan_signup function reported an error trying to load the specified Syslog Event Detector DLL library.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_SYSMGR_RELOAD_FM : [chars]: Failed to load Sysmgr FD DLL [chars]; return code=[dec]
Explanation

The sysmgr_reload_fh_detector function reported an error trying to load the specified Sysmgr Event Detector DLL library.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_THREADPOOL_MAX : Maximum number ([dec]) of callback events exceeded for [chars]; There is no available thread
in the threadpool to service the event.
Explanation

An attempt to schedule an event requiring a callback failed because there is no available thread in the threadpool.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_THREAD_POOL_START : [chars]: Error reported by thread_pool_start function; [chars]
Explanation

The thread_pool_start function reported an error while attempting to start the thread pool.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_WB_CREATE : [chars]: create_watched_boolean failed; [chars]
Explanation

The create_watched_boolean function reported an error trying to createthe watched boolean.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_WDSYSMON_RELOAD_FM : [chars]: Failed to load WDSysMon FD DLL [chars]; return code=[dec]
Explanation

The wd_reload_fh_detector function reported an error trying to load the specified WDSysMon Event Detector DLL library.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_WQ_CREATE : [chars]: create_watched_queue failed; [chars]
Explanation

The create_watched_queue function reported an error trying to createthe watched queue.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_XDM_DISPATCH_FAIL : [chars]: XOS Dispatch Manager dispatch error: [dec]
Explanation

XOS Dispatch Manager reports an error when dispatching an event.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_XDM_WAIT_FAIL : [chars]: XOS Dispatch Manager wait error: [dec]
Explanation

XOS Dispatch Manager reports an error when waiting for an event.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.
%HA_EM-7-FMS_XOS_DM_EXECUTE : [chars]: Failed to attach a handler to process child process exit; [chars]
Explanation

The xos_dm_execute function reported an error trying to attach the handler to process child process exit.
Recommended Action

Copy the message exactly as it appears, and report it your technical support representative.

HA_PROXY

%HA_PROXY-3-PROXY_IPC_PAK_ALLOC_FAILED :
Explanation

Allocation of IPC packet failed.
Recommended Action

LOG_STD_ACTION
%HA_PROXY-2-HA_SESSION_ALLOC_FAILED : [chars]: unable to allocate entry for [chars] binding
Explanation

HA could not allocate a control block to manage the service
Recommended Action

LOG_STD_ACTION
%HA_PROXY-2-HA_FIND_SERVICE_FAILED : [chars]: unable to find [chars] service
Explanation

HA could not find the specified service
Recommended Action

LOG_STD_ACTION
%HA_PROXY-3-HA_DUP_SERVICE_NAME : [chars]: Duplicate service name: [chars] on bind
Explanation

Duplicate service name on ha service bind
Recommended Action

LOG_STD_ACTION
%HA_PROXY-3-HA_DUP_SERVICE_INDEX : [chars]: Duplicate service index: [dec] on bind
Explanation

Duplicate service index on ha service bind
Recommended Action

LOG_STD_ACTION
%HA_PROXY-3-HA_INVALID_REQUEST : [chars]: Unknown request: [dec]
Explanation

HA control services received unknown request
Recommended Action

LOG_STD_ACTION
%HA_PROXY-3-HA_MALFORMED_PKT : Malformed packet bad [chars] [hex], MSGDEF_LIMIT_MEDIUM
Explanation

HA Sync packet was malformed, may not have been fully processed
Recommended Action

LOG_STD_ACTION
%HA_PROXY-4-HA_UNKNOWN_SERVICE : Sync msg for unknown service [hex] rg [hex], MSGDEF_LIMIT_MEDIUM
Explanation

HA Sync received a message for an unknown service
Recommended Action

LOG_STD_ACTION
%HA_PROXY-4-HA_PKT_ERROR : Error processing HA sync pkt, rg [hex], MSGDEF_LIMIT_MEDIUM
Explanation

HA Sync packet was dropped while processing
Recommended Action

LOG_STD_ACTION

HDLC

%HDLC-1-ISSU_NOMEMORY : msgtxt_nomemory
Explanation

The requested operation could not be accomplished because of a low memory condition.
Recommended Action

Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.
%HDLC-4-ISSU_SENDFAILED : HDLC ISSU: send message failed, rc = [dec]
Explanation

The sending of a message has failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%HDLC-4-ISSU_INCOMPATIBLE : hdlc-issu-compat: returned FALSE
Explanation

The compatibility checking has failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%HDLC-4-ISSU_XFORM : [chars]: failed, rc=[chars]
Explanation

The transform has failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.

HFSLIB

%HFSLIB-3-HFSOPEN : Problem accessing the udev generated file: [chars]
Explanation

No explanation.
Recommended Action

No action is required.
%HFSLIB-3-HFSINOFAILED : Inotify failed to initialize : [chars]
Explanation

This error occurs when the inotify sub-system is misbehaving
Recommended Action

No action is required.
%HFSLIB-3-HFSINOWATCH : Inotify failed to add a watch: [chars]
Explanation

This error occurs when the inotify sub-system is misbehaving
Recommended Action

No action is required.

HMAN

%HMAN-3-CONSOLE_SETUP_FAILED : Failed to setup console service. It should be enabled on [chars]
Explanation

Setup of a console service failed.
Recommended Action

Check the host manager launch parameters and correct as required.
%HMAN-3-HOSTNAME_SET_FAILED : Failed to set hostname: [chars]
Explanation

The host manager received notification that the system hostname has been set. The host manager failed to pass this value to
the ASR kernel.
Recommended Action

Repeat the process to configure the hostname. If the problem persists, copy the message exactly as it appears on the console
or in the system log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using
the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case,
or contact your Cisco technical support representative and provide the representative with the gathered information.
%HMAN-2-INITIALIZATION_FAILED : Host Manager initialization failed.
Explanation

Initialization of the host manager failed.
Recommended Action

Review Host Manager logs taking note of the timestamp information to select specific information to review. Copy the message
and other related information exactly as it appears on the console or in the system log. Research and attempt to resolve the
issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using
the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case,
or contact your Cisco technical support representative and provide the representative with the gathered information.

HMAN_CPU

%HMAN_CPU-3-PAGE_FAULT_HIGH : CPU Usage due to Memory Pressure exceeds threshold on [chars]. Below are the top 5 memory consuming
processes: [chars] (PID=[dec] RSS=[dec] MB),
Explanation

When CPU usage due to Major Page Fault exceeds a pre-defined threshold for a CPU core, this error message is emitted.
Recommended Action

No action is needed if system continues to perform as expected. If sytem performance deteriorate (and eventually, system reloads
due to unspecified reason) around the time when this message is observed, open a case with the Technical Assistance Center
via the following Internet link, or contact your Cisco technical support representative: https://mycase.cloudapps.cisco.com/case

HPI

%HPI-3-FAILED_START : channel:[chars] DSP ID:[hex], failed mode [dec] for service [dec]
Explanation

Failed to start DSP services
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HPI-3-INVALID_PAYLOAD : wrong payload size, channel:[chars] DSP ID:[hex], failed mode [dec] for service [dec]
Explanation

Failed to start DSP services
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HPI-3-CODEC_NOT_LOADED : channel:[chars] DSP ID:[hex], command failed as codec not loaded [dec]
Explanation

Sending messages to DSP without a loaded codec can result with the DSP failing
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HPI-4-INVALID_CODEC_LOAD : channel:[chars] DSP ID:[hex], invalid hpi mode [dec] for loading codec [dec]
Explanation

Attempt to load codec when the DSP is in an invalid mode which can result with DSP failure
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HPI-4-NO_CLOSE : channel:[chars] DSP ID:[hex]
Explanation

Attempt to release DSP without sending close message
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HPI-4-INVALID_ECAN_TYPE : [chars] ECAN is not available in voice-card [dec], [chars] ECAN will be used
Explanation

All voice cards participated in DSPFarm must have the same echo canceller type
Recommended Action

Make sure all voice cards participated in DSPFarm have the same echo canceller type configured
%HPI-3-GSMAMRNB_LICENSE_NOT_ACTIVATED : ********************************************************* GSM AMR-NB License is not
yet activated. Please configure ‘license feature gsmamrnb-codec-pack’ and accept the EULA to activate the license. *********************************************************
Explanation

Failed to start DSP services for GSM AMR-NB codec
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HPI-6-SRTP_EVAL_LIMIT : The SRTP bandwidth and tunnels usage exceed the license limits
Explanation

The SRTP bandwidth and tunnels exceed the license limits
Recommended Action

No action is required.
%HPI-3-SRTP_EVAL_FREE_ERROR : Error encountered on release SRTP bandwidth and tunnels reservation
Explanation

Error encountered on release SRTP bandwidth and tunnels
Recommended Action

No action is required.
%HPI-3-NACK_HIGH : DSP to IOS Nack message with severity [chars] [chars] [chars]
Explanation

DSP to IOS Nack message with high severity
Recommended Action

Check the NACKed message’s parameters for configuration errors. These messages tend to affect call flow, thus they are labeled
with high severity.
%HPI-4-NACK_MED : DSP to IOS Nack message with severity [chars] [chars] [chars]
Explanation

DSP to IOS Nack message with medium severity
Recommended Action

Check the NACKed message’s parameters for minor configuration errors.
%HPI-6-NACK_LOW : DSP to IOS Nack message with severity [chars] [chars] [chars]
Explanation

DSP to IOS Nack message with low severity
Recommended Action

Information only, displaying NACKed messages that are for debugging purposes.
%HPI-6-NACK : DSP to IOS Nack message [chars] [chars]
Explanation

DSP to IOS Nack message with no severity in order to work with dspware without Nack severity implementation
Recommended Action

Information only, displaying NACKed messages.

HSRP

%HSRP-3-NOSOCKET : Unable to open socket
Explanation

The system was unable to initialize an IP connection for the Hot Standby protocol.
Recommended Action

Make sure that there is at least one interface configured to run IP.
%HSRP-4-BADAUTH : Bad authentication from [chars], group [dec], remote state [chars]
Explanation

Two routers participating in HSRP disagree on the valid authentication string.
Recommended Action

Use the standby authentication command to repair the HSRP authentication discrepancy between the local system and the one
whose IP address is reported.
%HSRP-4-BADAUTH2 : Bad authentication from [chars]
Explanation

Two routers participating in HSRP disagree on the valid authentication string.
Recommended Action

Use the standby authentication command to repair the HSRP authentication discrepancy between the local system and the one
whose IP address is reported.
%HSRP-3-MISCONFIG : Attempt to change [chars] MAC address to [enet] when DECNET already running
Explanation

An HSRP group attempted to become active on an interface that can only support a single MAC address and which is running DECnet.
If standby use-bia is not configured then HSRP would normally set the interface MAC address to the HSRP virtual MAC address,
but this is not allowed if DECnet is running.
Recommended Action

Enable standby use-bia on the interface.
%HSRP-5-STATECHANGE : [chars] Grp [dec] state [chars] -> [chars]
Explanation

The router has changed state
Recommended Action

No action is required.
%HSRP-4-DUPADDR : Duplicate address [chars] on [chars], sourced by [enet]
Explanation

The IP address in an HSRP message received on the specified interface is the same as the IP address of the router. Another
router might be configured with the same IP address. The most likely cause is a network loop or a misconfigured switch that
is causing the router to see its own HSRP Hello messages.
Recommended Action

Check the configurations on all the HSRP routers to ensure that the interface IP addresses are unique. Check that no network
loops exist. If port channels are configured check that the switch is correctly configured for port-channels. Enable standby
use-bia so that the error message displays the interface MAC address of the sending router. This can be used to determine
if the error message is caused by a misconfigured router or a network loop.
%HSRP-4-DUPVIP1 : [chars] Grp [dec] address [chars] is already assigned to [chars] group [dec]
Explanation

The HSRP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to a different HSRP
group.
Recommended Action

Check the configuration on all HSRP routers and ensure that the virtual IP address of each HSRP group is unique.
%HSRP-4-DUPVIP2 : [chars] Grp [dec] address [chars] is already assigned on this interface
Explanation

The HSRP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to this interface.
Recommended Action

Check the configuration on all HSRP routers and ensure that the virtual IP address of each HSRP group is unique.
%HSRP-4-DUPVIP3 : [chars] Grp [dec] address [chars] is already assigned to, or overlaps with, an address on another interface
or application
Explanation

The HSRP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to, or overlaps with,
an address on another interface or application.
Recommended Action

Check the configuration on all HSRP routers and ensure that the virtual IP address of each HSRP group is unique.
%HSRP-4-BADVIP : [chars] Grp [dec] address [chars] is in the wrong subnet for this interface
Explanation

The HSRP virtual IP address contained in the Hello message cannot be learnt as it is not within a subnet configured on the
interface.
Recommended Action

Check the configuration on all HSRP routers and ensure that the virtual IP address is within a configured subnet.
%HSRP-4-DIFFVIP1 : [chars] Grp [dec] active routers virtual IP address [chars] is different to the locally configured address
[chars]
Explanation

The HSRP virtual IP address contained in the Hello message from the Active router is different from the virtual IP address
configured locally.
Recommended Action

Check the configuration on all HSRP routers in the group and ensure they are all configured with the same virtual IP address.

HTSP

%HTSP-3-NOEVENT : no free event structure available from [chars] for DSP message
Explanation

There were no event structures remaining in the system pools to alert the router of a voice or signaling event.
Recommended Action

Check that the voice port for which the event was reported is still operational. If not, clear the voice port.
%HTSP-3-CAPABILITYMISMATCH : voice port [chars]: call connection id [[hex] [hex] [hex] [hex]]
Explanation

There was a capabilities mismatch between the two call legs. capabilities are negotiated between call legs for CODEC, VAD
and FAX rate.
Recommended Action

Check that the dial peer configuration is appropriate for the interface in question. Also check that and configuration on
the interface is correct.
%HTSP-3-DSPALARM : voice port [chars]: status=[hex] message=[hex] text=[chars]
Explanation

The DSP reported a fatal error. All calls on the DSP were dropped and a DSP reload was attempted.
Recommended Action

Verify that the DSP reloaded properly by attempting to place a call on the affected voice port. Contact your technical support
representative, include the full text of the error message.
%HTSP-3-TRUNKNOTSUPPORTED : voice port [chars]: Ground Start trunking not supported
Explanation

This voice port does not support the ‘connection trunk’ command when ground start signaling is configured. Trunking mode on
this voice is supported when using loop start signaling.
Recommended Action

Shut down the voice port, remove the ‘connection trunk’ and/or ‘signal groundStart’ command from the voice port configuration,
and unshut the voice port.
%HTSP-5-UPDOWN : Trunk port(channel) [[chars]] is [chars]
Explanation

Trunk port:channel changed state.
Recommended Action

No action is required.
%HTSP-3-CADENCENOTSUPPORTED : voice port [chars]: ring cadence not suitable for caller id. on_time_first=[dec] off_time_first=[dec]
on_time_second=[dec] off_time_second=[dec]
Explanation

Ring off period is not sufficient for caller id transmission. If caller id transmission during ring is configured make sure
that the ring off duration is long enough.
Recommended Action

If caller id transmission during ring is configured make sure that the ring off duration is long enough. Make sure that the
cptone setting and caller-id alerting settings are correct.
%HTSP-5-VPM_BUSYOUT : voice port [chars]: [chars] busyout
Explanation

voice port busyout status changed
Recommended Action

use SHOW VOICE BUSYOUT to find out the reason why voice port busyout monitoring is triggered
%HTSP-5-VPM_PCM_CAPTURE : User trigger PCM capture is [chars] on voice port [chars]
Explanation

User trigger PCM capture is enabled or disable on this voice port
Recommended Action

This is just for information only
%HTSP-5-VPM_CABLE_STAT : voice port [chars]: cable [chars]
Explanation

Cable for analog voice port is reconnected or removed
Recommended Action

Check the cable connection for this analog voice port

HTTP through IDB_IDENTITY

  • HTTP

  • HTTPC

  • HUNTGRP

  • HW_API

  • HW_FLOWDB

  • HW_IDPROM_ENVMON

  • HW_PFU

  • ICC

  • IDBMAN

  • IDB_IDENTITY

HTTP

%HTTP-3-PROC_NOCREAT : Unable to create HTTP process.
Explanation

An error occurred during initialization of the HTTP process. The HTTP process that processes all HTTP requests and responses
could not be created.
Recommended Action

Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.
%HTTP-4-SERVER_CONN_RATE_EXCEED : Number of connections per minute has exceeded the maximum limit([dec]) as specified by
the platform.
Explanation

The message indicates that the current number of connections requested per minute has exceeded the limit specified by the
platform. HTTP server will resume accepting the connections 15 seconds from the time the message is issued. This restriction
is done as per the HTTP throttling functionality.
Recommended Action

Reduce connection rate to the server.
%HTTP-3-OUTOF_MEM : HTTP out of memory.
Explanation

An error occurred during initialization of the HTTP process. The HTTP process could not create crucial internal data structures
that are required for operation of the HTTP subsystem. The most likely reason for this condition is an exhaustion of system
memory.
Recommended Action

Reduce other system activity to ease memory demands. if conditions warrant, upgrade to a larger memory configuration.
%HTTP-3-INIT_FAIL : HTTP Process Init failed.
Explanation

Initialization of the HTTP Subsystem has failed
Recommended Action

Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.
%HTTP-6-SERVER_SETUP_FAILED : Server setup failed
Explanation

Setup of the HTTP(S) server to listen on the specified port number has failed.
Recommended Action

Disable the server, verify that port number is correct and enable the server. Reduce other system activity to ease memory
demands. If conditions warrant, upgrade to a larger memory configuration.

HTTPC

%HTTPC-3-PROC_NOCREAT : Unable to create HTTP Client process.
Explanation

Recommended Action

%HTTPC-3-OUTOF_MEM : HTTP Client out of memory.
Explanation

Recommended Action

%HTTPC-3-CACHE_MEM : HTTP Client Cache Init out of memory.
Explanation

Recommended Action

%HTTPC-3-INIT_FAIL : HTTP Client Process Init failed.
Explanation

Recommended Action

%HTTPC-3-OUTOF_SYNC : HTTP Client header tables out of sync.
Explanation

Recommended Action

%HTTPC-6-CONNECT_FAILED : The connection to server [IP_address] failed
Explanation

Recommended Action

%HTTPC-3-RECEIVE_SOCK_READ_EVENT_WHILE_DISABLED : Received socket read event while read interest is disabled callID([dec])
fd([dec]) — closing socket.
Explanation

The HTTP Client is receiving the socket READ event while the READ interest is being disabled. Something has gone wrong between
the http client and the socket interfaced.
Recommended Action

Record the error and report it to the system administrator.
%HTTPC-3-CONNECT_NULL : NULL connection structure for fd([dec]) — closing socket.
Explanation

The HTTP Client is receiving the socket READ event but it fails to locate the connection structure for this file descriptor(fd).
If this is seen continuously in a loop, it is an indication that something has gone wrong in the socket code. Since the socket
is immediately closed after this event, the HTTP client should stop seeing READ event.
Recommended Action

Record the error and traceback and report it to the system administrator.
%HTTPC-6-REQUEST_FAILED : request URI [chars] failed
Explanation

Recommended Action

%HTTPC-6-CLOSE_SRV_CONNECT : The connection to server [IP_address] appears to be hung and will be closed.
Explanation

Messages are being backed up in the HTTP Client’s write queue in the connection with the specified server. The connection
is assumed to have gone bad and the HTTP Client is closing the connection.
Recommended Action

Check with the specified server for possible connection error.
%HTTPC-3-COOKIE_MEM : HTTP Client runs out of allowable memory to store cookies.
Explanation

The total memory allocated for storing cookies has run out. All cookies received from the HTTP server will be dropped. Users
may no longer be able to interact with a session-based origin server until memory is freed up.
Recommended Action

Users may want to try their requests at a later time or contact the system administrator to increase the maximum RAM allowed
for saving HTTP cookies.

HUNTGRP

%HUNTGRP-3-INVALID_URL : Could not open the file provided in URL: <[chars]>
Explanation

URL path provided can’t be accessed. This usually indicates that path provided is invalid but may also be because the the
path doesn’t allow anonymous access to create files or open it in write mode
Recommended Action

Check that the url path provided is valid
%HUNTGRP-3-WRITE_FAIL : Could not write data to the URL: <[chars]>t %%bytes written=[dec] out of [dec]
Explanation

Write attempt to the url path provided was unsuccessful. This usually indicates that the file was successfully opened with
write and append permissions but writing all the content from buffer or may be some of it to the file failed.
Recommended Action

HW_API

%HW_API-3-RESILIENCE_NO_HANDLER : No handlers in place for [chars] sw object creation failure.
Explanation

COMMON_HW_API_INTERNAL_ERROR
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HW_API-3-INVALID_OBJ : Invalid object [hex]
Explanation

HW_API_INTERNAL_ERROR
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HW_API-3-INVALID_TYPE : Invalid type [dec]
Explanation

HW_API_INTERNAL_ERROR
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HW_API-3-INVALID_WALK_SPEC : Invalid walk spec [hex]
Explanation

HW_API_INTERNAL_ERROR
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HW_API-3-WALK_MODE_UNSUPPORTED : Walk mode ‘[chars]’ unsupported
Explanation

HW_API_INTERNAL_ERROR
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HW_API-3-INVALID_CONTEXT : Invalid context [hex]
Explanation

HW_API_INTERNAL_ERROR
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HW_API-3-BACKWALK_REQUEST : Backwalk request failed, [chars]
Explanation

A request to walk internal data structures has failed. Depending on criticality of the data, accuracy of forwarding may impacted.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HW_API-3-BACKWALK_REQUEST_VALUE : Backwalk request failed, [chars] ([hex])
Explanation

A request to walk internal data structures has failed. Depending on criticality of the data, accuracy of forwarding may impacted.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HW_API-3-VECTOR : Failed to set [chars] vector for [chars], [chars]
Explanation

HW_API_INTERNAL_ERROR
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HW_API-3-NO_OBJ_TYPE_LIST_ENTRY : Invalid sw_obj_type ([dec]) used with obj_type_list
Explanation

HW_API_INTERNAL_ERROR
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HW_API-3-NO_OBJ_TYPE_LIST_ENTRY2 : Invalid sw_obj_link_type ([dec]) used with obj_type_list
Explanation

HW_API_INTERNAL_ERROR
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%HW_API-3-INIT_FAIL : HW-API init [chars] failed[chars]
Explanation

HW_API_INTERNAL_ERROR
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

HW_FLOWDB

%HW_FLOWDB-3-HW_FLOWDB_OOM : FlowDB memory usage exceeded 95[int]sage. OOM condition can occur.
Explanation

FlowDB running low on memory. Out-of-memory condition can occur
Recommended Action

Check sw-distrib for actual utilization of FlowDB memory

HW_IDPROM_ENVMON

%HW_IDPROM_ENVMON-3-HW_IDPROM_FIELD_INVALID : The idprom contains an invalid environmental monitoring field.
Explanation

If this error occurs then parsing of the environmental monitoring data is aborted. Environmental monitoring will be either
incomplete or absent entirely.
Recommended Action

If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search
of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%HW_IDPROM_ENVMON-3-HW_IDPROM_CHECKSUM_INVALID : The idprom contains an invalid checksum in a sensor entry. Expected: [hex],
calculated: [hex]
Explanation

If this error occurs then parsing of the environmental monitoring data is aborted. Environmental monitoring will be either
incomplete or absent entirely.
Recommended Action

If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search
of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%HW_IDPROM_ENVMON-2-ACT2_UDI_DATA_INVALID : The act2 udi secure area format mismatch with unsecure area
Explanation

This Router may not have been manufactured by Cisco or with Cisco’s authorization. This product may contain software that
was copied in violation of Cisco’s license terms. If your use of this product is the cause of a support issue, Cisco may deny
operation of the product, support under your warranty or under a Cisco technical support program such as Smartnet. Please
contact Cisco’s Technical Assistance Center for more information.
Recommended Action

If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search
of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%HW_IDPROM_ENVMON-3-PS_IDPROM_INVALID_PID : [chars] in slot PFU[dec] has INVALID PID [chars] and it needs to be replaced immediately
Explanation

The PID read from the PEM IDPROM is not supported in this hardware configuration. It will be allowed to continue but immediate
replacement is required
Recommended Action

If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search
of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.

HW_PFU

%HW_PFU-3-PFU_IDPROM_READ_ERR : Could not read the PEM/FM idprom in slot P[dec].The system will run without environmental
monitoring for this component
Explanation

The idprom contains information required in order to properly operate the environmental monitoring subsystems. The idprom
could not be read, therefore no monitoring will take place.
Recommended Action

If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search
of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%HW_PFU-3-PFU_IDPROM_CORRUPT : The PEM/FM idprom could be read, but is corrupt in slot P[dec] The system will run without
environmental monitoring for this component
Explanation

The idprom contains information required in order to properly operate the environmental monitoring subsystems. The idprom
could not be read, therefore no monitoring will take place.
Recommended Action

If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search
of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%HW_PFU-3-PFU_IDPROM_INVALID_PID : The PEM/FM idprom has invalid PID in slot PFU[dec] The system will run without environmental
monitoring for this component
Explanation

The idprom contains PID information required in order to properly operate the environmental monitoring subsystems. The idprom
PID is invalid , therefore no monitoring will take place.
Recommended Action

If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search
of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.

ICC

%ICC-2-NOMEM : No memory available for [chars]
Explanation

The ICC subsystem could not obtain the memory it needed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%ICC-4-CONSISTENCY : Internal consistency check: [chars]
Explanation

An internal inconsistency was found in some ICC data structures.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%ICC-4-COMM : Communication failure occurred while [chars]
Explanation

Recommended Action

%ICC-4-BAD_ACCOUNTING : ICC received a bad class [dec]
Explanation

A communication failure has occurred between this card and another card in the system.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%ICC-4-HEARTBEAT : Card [dec] failed to respond to heartbeat
Explanation

A communication failure has occurred between the primary and the specified line card.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%ICC-5-WATERMARK : [dec] [chars] [chars] pkts for class [chars] are waiting to be processed
Explanation

Processor got packets for the class and are waiting to be procssed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%ICC-2-OPEN : ICC Create Session Failed for card <[hex]> Queue <[chars]>
Explanation

ICC was not able to create a session for the destination seat
Recommended Action

collect output from ‘show oir debug swover_global_mask’ from SP
%ICC-2-JOIN : ICC mcast joining failed member <[hex]> to group <[hex]> with ipc error <[chars]>
Explanation

ICC was not able to join a member for the mcast group
Recommended Action

collect output ‘show icc mcast status’ from RP
%ICC-5-HUGE_BUFFER : Class [[chars]] with Request id [dec] requested a huge buffer of Size [dec].
Explanation

Huge packet requests would deplete the memory at the linecards
Recommended Action

ICC client is trying to request huge packet buffer Please use the command Show icc internal to get get the traceback and file
a DDTS against the component
%ICC-3-MAST_BAD_FREE : ICC multicast memory already freed
Explanation

One of the ICC multicast request’s memory was found to be free when response arrived
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.

IDBMAN

%IDBMAN-3-VLANINUSE : [chars]: Vlan [dec] is in use by [chars]
Explanation

Each L3 interface has a Vlan associated with it. This message indicates that the Vlan associated with the interface is being
used by some other L3 Interface, which is not anticipated to happen
Recommended Action

No action is required.
%IDBMAN-3-INVALIDVLAN : [chars]: trying to use invalid Vlan [dec]
Explanation

There is an internal error that caused an invalid Vlan to be used by the software.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDBMAN-3-VLANNOTSET : [chars]: Vlan [dec] not set since it already has Vlan [dec]
Explanation

There is an internal error that caused an interface to not have its Vlan set to the requested value
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDBMAN-6-VLANMAPPED : Vlan [dec] is mapped to [chars]
Explanation

Informational message indicating that the given Vlan is mapped to the given interface
Recommended Action

No action is required.
%IDBMAN-3-AGGPORTMISMATCH : [chars]([dec] / [dec]) does match internal slot/port state [chars]([dec] / [dec])
Explanation

There is an internal error that caused an invalid aggregate port to be used by the software.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDBMAN-3-INVALIDAGGPORTBANDWIDTH : [chars]([dec] / [dec]) has an invalid bandwidth value of [dec]
Explanation

There is an internal error that caused an invalid bandwidth to be used for an aggregate port.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDBMAN-3-DELETEDAGGPORT : [chars]([dec] / [dec]) Group [dec] has been deleted, but is being reused.
Explanation

There is an internal error that caused an interface that has been deleted to be reused for a new aggregate port.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDBMAN-3-NOTANAGGPORT : [chars]( [dec] / [dec] ) is not an aggregate port
Explanation

There is an internal error that caused an interface that is not an aggregate port to be used for aggregate port operations
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDBMAN-3-INVALIDPORT : [chars]: trying to use invalid port number [dec] ( Max [dec] )
Explanation

There is an internal error that caused an invalid port numer to be used by the software.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDBMAN-4-ACTIVEPORTSINAGGPORT : [chars]( [dec] / [dec] ) has [dec] active ports, but is being removed
Explanation

There is an internal error that caused an aggregate port with active ports to be removed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDBMAN-3-PORTNOTINAGGPORT : [chars]([dec] / [dec]) is not present in Aggport [chars]([dec] / [dec])
Explanation

There is an internal error that caused an invalid port to be referred to be part of an aggregate port.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDBMAN-4-REMOVED_NONDEFAULT_CONFIG : Removed non default configuration for interfaces in slot [dec]
Explanation

In SSO mode, the non-default configuration for any removed linecard is not synced to the standby during the bulk sync, and
it is removed from the configuration to avoid a config mismatch between active and standby supervisors.
Recommended Action

No action is required.
%IDBMAN-3-IIF_ID_REGISTRATION_FAILED : IIF_ID registration failed for Port [chars] due to memory allocation failure. Port
has been shutdown
Explanation

The system is low on memory due to which IIF-ID registration failed. This results in failure to apply polices such as QoS
and Security acls on this port.
Recommended Action

LOG_STD_REDUCE_ACTION Once memory is available, run ‘no shutdown’ on the port.

IDB_IDENTITY

%IDB_IDENTITY-3-MALLOC : Memory allocation failure for HWIDB type [dec]
Explanation

A memory allocation failure occured when trying to allocate the identity for this HWIDB. This HWIDB will not be allocated
an IF Index which will prevent it from being used for forwarding data.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IDB_SGI through ILPOWER

  • IDB_SGI

  • IDMGR

  • IEDGE

  • IF

  • IFDAMP

  • IFMAP

  • IFMGR

  • IFS

  • IKEV2

  • ILPOWER

IDB_SGI

%IDB_SGI-2-XDRREG : [chars]
Explanation

An internal software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDB_SGI-2-MEMREQ : [chars]
Explanation

An internal software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDB_SGI-3-BADPTR : [chars] of interface with ifindex [int] is invalid
Explanation

An internal software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDB_SGI-3-MEMFAIL : [chars]
Explanation

An internal software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDB_SGI-4-MEMBERREQ : member request failure for interface with ifindex [int] returned err — [chars]
Explanation

An internal software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDB_SGI-3-XDRREQ : [chars]
Explanation

An internal software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDB_SGI-4-INTERR : [chars] for interface with ifindex [int]
Explanation

An internal software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDB_SGI-4-UNEXPINP : [chars]
Explanation

An internal software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IDMGR

%IDMGR-3-MALLOC_FAILURE : [chars]
Explanation

A malloc failure occured in ID Manager.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDMGR-3-INTERRUPT : [chars]
Explanation

An id_get attempted at interrupt level.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDMGR-3-INVALID_ID : bad id in [chars] (id: [hex])
Explanation

An ID Manager error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDMGR-3-INVALID_ID_TABLE_SIZE : bad new ID table size
Explanation

A bad new table request to ID Manager occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IDMGR-3-ID_MANAGER_INTERNAL_ERROR : [chars]
Explanation

Internal Error occured with ID Manager.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IEDGE

%IEDGE-4-PBHK_DEPLETED_INDICES : No more portbundles can be allocated
Explanation

The source interfaces configured for Portbundle Hostkey feature are not sufficient and the number of portbundles available
are all used up. Add more source interfaces in the configuration.
Recommended Action

Check configuration on the ISG
%IEDGE-4-TC_UNDEFINED_ACL : Traffic class ACL [chars] is not defined, creating permit all ACL
Explanation

The ACL specified for classification of traffic is not configured on the ISG. Creating a permit all ACL. ACL should be configured
on the ISG.
Recommended Action

Configure the ACL on the ISG
%IEDGE-4-CLOCK_CHANGE_TIMER_INV : A Local clock change has caused a running timer to be invalid
Explanation

A change in local clock has made a currently running timer to be invalid
Recommended Action

Check the clock configuration
%IEDGE-3-CH_INTERNAL_ERROR : Internal error in command processing — session handle=[hex]
Explanation

There has been an internal error relating to CoA command processing.
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IEDGE-3-CH_REGISTER_ERROR : CoA registration error in command processing — type ‘[chars]’
Explanation

There has been an internal error relating to CoA command processing.
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.

IF

%IF-3-IDB_LIST_BAD_REF_COUNT : A bad reference count was encountered in an idb list element.
Explanation

A software error occurred.
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IF-2-IDB_TABLE_INIT : Malloc failed while initializing idb table
Explanation

Recommended Action

%IF-3-BAD_MTU : Internal error. MTU on [chars] too large or negative. Truncating from %ld to [int].
Explanation

An internal software error occurred. The system attempted to set the MTU on an interface to an invalid value.
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IF-3-BADLOCK : Invalid lock use for [chars]: [chars][chars]
Explanation

Application layer code attempted to access an unlocked interface.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IF-3-BADHWUNLOCK : ([chars]) attempted to unlock [chars] ([dec]). Locked by [chars] ([dec]).
Explanation

Attempt to release semaphore held by another process.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IF-3-SEMAHOG : ([chars]) could not get [chars] semaphore. Held by ([chars]).
Explanation

Unable to obtain interface semaphore.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IF-4-BACKWARD_COUNTERS : Corrected for backward [chars] counters ([int] -> [int]) on [chars]
Explanation

The interface specified in the message has a packet counter that has decreased in number. This condition can occur if a packet
is counted and then dropped. This event was detected and corrected.
Recommended Action

If this condition persists, copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather data that may help identify the nature of the error. If you cannot determine the nature of the error from
the error message text or from the show tech-support command output, contact your Cisco technical support representative and provide the representative with the gathered information.
%IF-3-BADMACADDRTYPE : illegal mac address type, [dec]
Explanation

This is an interal error that was recovered gracefully.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IF-4-NOBGPROCESS : Network background process not running. [chars]
Explanation

A process which manages network interface background processing is not yet running, but another system process has tried to
send the process a message.
Recommended Action

An interface on the router may have missed a request to bring itself up. If that happens, it may be necessary to reset the
interface using a shutdown operation and then a no shutdown.

IFDAMP

%IFDAMP-5-UPDOWN : interface [chars] update [chars] state to [chars], interface is [chars]suppressed
Explanation

dampening interface changed state.
Recommended Action

No action is required.
%IFDAMP-5-ZERODELAY : dampening reuse timer is updated with 0 delay time
Explanation

Inconsistency of dampening reuse timer wheel
Recommended Action

No action is required.

IFMAP

%IFMAP-3-CAUSE_CFG : hash table not initialized
Explanation

PAL interface handle to uidb hash table not initialized
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IFMGR

%IFMGR-3-IFINDEX_PERSIST_ENTRY_CORRUPT : [chars] seems to be corrupted. Trying to read [dec] size
Explanation

The ifIndex-table seems to be corrupted.
Recommended Action

Delete the ifindex-table.
%IFMGR-3-INVALID_PERSISTENT_DATA : Invalid persistent data
Explanation

Trying to write invalid persistent data
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IFMGR-3-NOVECTOR : Interface manager failed to allocate IF vector. size [dec]
Explanation

The interface vector was not able to be allocated with the number of elements required—initially or resize (see size in the
error message).
Recommended Action

TBD
%IFMGR-3-VECTOREXD : IF manager attempted to use interface [dec] outside vector range.
Explanation

This message indicates that an interface with too large of an ifIndex value was attempted to be added to the IF-MGR DB.
Recommended Action

Additional IF-MGR warning and/or error messages should accompany indication of this error. These additional messages should
provide more details on the effected interface.
%IFMGR-3-VECTORPOSUSED : IF manager attempted to add interface [dec] which was already added.
Explanation

This message comes from the IF-MGR DB when it is trying to add an ifIndex value for this interface which already exists in
the ifIndex DB.
Recommended Action

TBD
%IFMGR-4-VECTORIFSUSPECT : IF manager added interface [dec] which is unexpectedly large.
Explanation

The ifIndex allocation scheme gives out sequential ifIndex values. This message comes from the IF-MGR DB when it is trying
to add an ifIndex value much larger than the former greatest ifIndex value in the DB.
Recommended Action

TBD
%IFMGR-3-IFDB : IF manager interface database [chars] failure- [dec]
Explanation

Recommended Action

TBD
%IFMGR-3-IFTDB : IF manager interface table database [chars] failure- [dec]
Explanation

Recommended Action

TBD
%IFMGR-3-NOTYPEVECTOR : Interface manager failed to allocate IF type vector. size [dec]
Explanation

The interface type vector was not able to be allocated with the number of elements required—initially or resize.
Recommended Action

TBD
%IFMGR-3-NOIMACP : IF manager control process failed to start
Explanation

Recommended Action

TBD
%IFMGR-4-NOIFINDEX : All SNMP if indices are exhausted
Explanation

All SNMP MIB indices have been exhausted. Interfaces will not be able to obtain an interface index that they can use to register
with the interface MIB.
Recommended Action

Attempt a system reload. If the problem persists after the system reload, copy the message exactly as it appears on the console
or in the system log, contact your Cisco technical support representative, and provide the representative with the gathered
information.
%IFMGR-3-BADIFINDEXTABLE : The file nvram:ifIndex-table is corrupt.
Explanation

The file is not in the expected format.
Recommended Action

If possible, please delete the file.
%IFMGR-4-NOSYNC : ifIndex not being synced between active and standby
Explanation

When the standby comes up, then the tuple of ifIndex and ifDescr is synced so that when interfaces comes up they get the same
ifIndex. This error happens when the interface doesn’t get the ifIndex for the given ifDescr
Recommended Action

Inform the technical support to raise the ddts
%IFMGR-5-RESTART : [chars]
Explanation

The IF MGR process has restarted
Recommended Action

This is an informational message. The system should recover on its own.
%IFMGR-4-STACK_RELATIONSHIP_ADD_ERROR : [chars]: Request for creating invalid stack relationship [dec], [dec]
Explanation

The IF MGR received the call to add invalid stack relationship. The higher and lower ifIndex are shown in the message. The
module of the IF MGR from where this message is generated is also shown in the message
Recommended Action

Inform the technical support to raise the ddts
%IFMGR-3-DUP_IFINDEX : Duplicate ifIndex ([dec]) found for ifDescr [chars]; exists in ifTable for ifDescr [chars].
Explanation

Interfaces have same ifIndex in IF-MGR assigned list. The 2nd interface registered with IF-MGR will be assigned with new index
Recommended Action

1. No Action, if ifIndex persist is not required. 2. Reload the standby RP, if ERR msg only seen in standby RP 3. Reload the
router with the proper ifindex-table and image
%IFMGR-7-NO_IFINDEX_FILE : Unable to open [chars] [chars]
Explanation

This is a informational message. This means system found no saved ifIndex information, and ifIndex is not persisted across
reboots. The ifIndices will be reassigned.
Recommended Action

1. No Action, if ‘snmp-server ifIndex persist’ is not configured. 2. If ‘snmp-server ifindex persist’ is configured then copy
the error message exactly as it appears, and report it to your technical support representative.

IFS

%IFS-4-FILEMAX : Failed to open [chars], maximum open files [dec])
Explanation

The router has reached the maximum number of files that may be open at one time.
Recommended Action

Close some files and try again. If this messages recurs, contact your technical support representative.
%IFS-3-FSMAX : Failed to add [chars], maximum filesystems [dec]
Explanation

The router has reached the maximum number of file systems that can be supported at one time.
Recommended Action

Contact your technical support representative.
%IFS-3-FSDUP : Failed to add [chars], filesystem prefix exists
Explanation

A file system cound not be added because another file system exists with the same name.
Recommended Action

Contact your technical support representative.
%IFS-3-FS_CREATE_FAIL : Failed to create [chars] file system, [chars]
Explanation

An internal software error occurred.
Recommended Action

Call your technical support representative for assistance.
%IFS-3-FS_CREATE_FAIL2 : Failed to create [chars] simple file system, [chars]
Explanation

An internal software error occurred.
Recommended Action

Call your technical support representative for assistance.
%IFS-3-FS_MISSING_FUNCTIONS : ‘[chars]’ file system missing required functions, not created
Explanation

Some file systems require a certain set of function to be present in order to be usable. This file sustem does not support
all the mandatory functionality.
Recommended Action

Call your technical support representative for assistance.
%IFS-3-FS_STRUCT_ERROR : Data does not match expected internal representation
Explanation

A mismatch exists between the representation of data extracted from the filesystem and the expectation of its formatting.
This may occur when running in a dual-RP environment, with different IOS versions running on the two RPs.
Recommended Action

Ensure both RPs are running the IOS same version, if running in a dual-RP environment. If not, call your technical support
representative for assistance.

IKEV2

%IKEV2-5-OSAL_INITIATE_TUNNEL : NULL
Explanation

Recommended Action

%IKEV2-5-RECV_CONNECTION_REQUEST : NULL
Explanation

Recommended Action

%IKEV2-3-NEG_ABORT : NULL
Explanation

Recommended Action

%IKEV2-1-SEND_COOKIE_CHALLENGE : NULL
Explanation

Recommended Action

%IKEV2-5-IPSEC_COLLISION : NULL
Explanation

Recommended Action

%IKEV2-5-SA_UP : NULL
Explanation

Recommended Action

%IKEV2-5-SA_DOWN : NULL
Explanation

Recommended Action

%IKEV2-5-SA_REJECTED_RESOURCE_LOW : NULL
Explanation

Recommended Action

%IKEV2-5-SA_REJECTED_LIMIT_REACHED : [chars]
Explanation

Recommended Action

%IKEV2-5-INCREASE_PEER_WINDOW_SIZE : NULL
Explanation

Recommended Action

ILPOWER

%ILPOWER-3-ILPOWER_INTERNAL_IF_ERROR : Inline Power internal error, interface [chars]: [chars]
Explanation

A software check failed during Power over Ethernet (PoE) processing.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%ILPOWER-5-ILPOWER_POWER_DENY : Interface [chars]: inline power denied. Reason: [chars]
Explanation

There is not enough power remaining in the switch to supply to the Power over Ethernet (PoE) port.
Recommended Action

No action is required.
%ILPOWER-5-ILPOWER_POWER_CDP_SHUT : Interface [chars]: inline power shut
Explanation

Inline power is shut because cdp consumption power on this Power over Ethernet (PoE) port is greater than 1. allocation power
or 2. hardware interface limit or 3. user configured max power or 4. available power on this switch.
Recommended Action

No action is required.
%ILPOWER-3-CONTROLLER_ERR : Controller error, Controller number [dec]: [chars]
Explanation

An error reported or caused by the Power over Ethernet (PoE) controller is detected.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%ILPOWER-3-CONTROLLER_POST_ERR : Inline Power Feature is disabled on this switch because Power On Self Test (POST) failed
on this switch. Please consult TECH support for further assistance
Explanation

An error reported or caused by the Power over Ethernet (PoE) controller is detected during POST.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%ILPOWER-3-CONTROLLER_IF_ERR : Controller interface error, [chars]: [chars]
Explanation

An interface error is detected between the Power over Ethernet (PoE) controller and system.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%ILPOWER-3-CONTROLLER_PORT_ERR : Controller port error, Interface [chars]: [chars]
Explanation

A port error reported by the Power over Ethernet (PoE) controller is detected.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%ILPOWER-5-POWER_GRANTED : Interface [chars]: Power granted
Explanation

There is enough power available in the switch, and the switch is providing power on the interface.
Recommended Action

No action is required.
%ILPOWER-5-LINKDOWN_DISCONNECT : Interface [chars]: Link down disconnect
Explanation

The powered device is no longer connected to the switch, or the connected powered device is being powered by an external AC
power source. The switch is no longer providing power on the interface.
Recommended Action

No action is required.
%ILPOWER-5-IEEE_DISCONNECT : Interface [chars]: PD removed
Explanation

The powered device is no longer connected to the switch, or the connected powered device is being powered by an external AC
power source. The switch is no longer providing power on the interface.
Recommended Action

No action is required.
%ILPOWER-7-DETECT : Interface [chars]: Power Device detected: [chars]
Explanation

The switch has detected the attached power device.
Recommended Action

No action is required.
%ILPOWER-5-INVALID_IEEE_CLASS : Interface [chars]: has detected invalid IEEE class: [dec] device. Power denied
Explanation

The power device has invalid IEEE class. switch won’t powerup the device
Recommended Action

No action is required.
%ILPOWER-3-SHUT_OVERDRAWN : Interface [chars] is shutdown as it is consuming more than the maximum configured power ([dec])
milliwatts.
Explanation

Interface is shutdown because it is consuming more than the maximum configured power
Recommended Action

Make sure correct power is budgeted for this interface based on the power device electrical specifications or ratings. It
is recommended to change the police cutoff power to a higher value to keep the device powered on
%ILPOWER-4-LOG_OVERDRAWN : Interface [chars] is overdrawing power. it is consuming [dec] milliwatts where as maximum configured
power is ([dec]) milliwatts.
Explanation

Recommended Action

Make sure correct power is budgeted for this interface based on the power device electrical specifications or ratings. Otherwise
you might risk overloading the switch. It is recommended to change the police cutoffpower appropriately if needed
%ILPOWER-5-CLR_OVERDRAWN : Interface [chars] is NOT overdrawing power. it is consuming [dec] milliwatts where as maximum
configured value is ([dec]) milliwatts.
Explanation

Recommended Action

No action is required.
%ILPOWER-5-POLICE_POWER_INVALID : Interface [chars]: invalid power police [dec] milliwatts current [dec] mA voltage [dec]
mV
Explanation

power policing current or voltage value is invalid.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%ILPOWER-5-SENSE_POWER_INVALID : Interface [chars]: invalid power sense [dec] milliwatts current [dec] mA voltage [dec] mV
Explanation

power sensing current or voltage value is invalid.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%ILPOWER-4-ILPOWER_POWER_SUPPLY : PoE Power Supply [chars]: [chars]
Explanation

The power supply for PoE is OIR
Recommended Action

Make sure power supply to PoE input is inserted after removal
%ILPOWER-4-ILPOWER_PS_ABSENCE : PoE module Power Supply not present Inline Power Feature is disabled on [chars] because Power
On Self Test (POST) failed : [chars]
Explanation

The power supply for PoE expansion module is not present or not inserted properly or faulty
Recommended Action

Make sure power supply to expansion module is inserted properly and reload the switch with PoE power supply present
%ILPOWER-5-PWRGOOD_SPARE_PAIR : Interface [chars]: spare pair power good
Explanation

Spare pair power request was successful and power is available on spare pair
Recommended Action

No action is required.
%ILPOWER-5-TSTART_SPARE_PAIR : Interface [chars]: spare pair power error: TSTART
Explanation

spare pair tstart error has occurred, power on spare pair will not be supplied
Recommended Action

No action is required.
%ILPOWER-5-PGOOD_TIMEOUT_SPARE_PAIR : Interface [chars]: spare pair power good timeout error
Explanation

spare pair power good timeout error has occurred, power on spare pair will not be supplied
Recommended Action

No action is required.
%ILPOWER-5-DET_SHORT_SPARE_PAIR : Interface [chars]: spare pair short detected
Explanation

spare pair short detect error has occurred, power on spare pair will not be supplied
Recommended Action

No action is required.
%ILPOWER-5-DET_TIMEOUT_SPARE_PAIR : Interface [chars]: spare pair detect timeout
Explanation

spare pair timeout detect error has occurred, power on spare pair will not be supplied
Recommended Action

No action is required.
%ILPOWER-6-SET_ILPOWER : Set power allocated to POE to [dec] for slot [dec]
Explanation

The power allocated to POE has changed
Recommended Action

No action is required.
%ILPOWER-5-SINGLE_PAIRSET_FAULT : Interface [chars]: shutting down [chars] pairset due to fault
Explanation

The dual signature PD on this port has hit a critcal fault on one pairset and hence that pairset will be shutdown
Recommended Action

No action is required.
%ILPOWER-5-LLDP_SHUTDOWN : Interface [chars]: PD requested shutdown for [dec] sec via LLDP MDI TLV
Explanation

Inline power is removed because PD requested shutdown via LLDP MDI TLV
Recommended Action

No action is required.

IM through IOSD_INFRA

  • IM

  • IMGR

  • INDXOBJ

  • INFRA

  • INSTALL

  • INTERCHASSIS_REDUNDANCY

  • INTERFACE_API

  • IOMD_INFRA

  • IOSD

  • IOSD_INFRA

IM

%IM-0-UIPEER_CREATE : Failed to create user interface peer.
Explanation

The system failed to create a user interface peer.
Recommended Action

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number
reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output
of show tech-support and provide the gathered information to a Cisco technical support representative.
%IM-2-INITIALIZATION_FAILED :
Explanation

Initialization of IOx Manager process failed.
Recommended Action

Review ioxman logs taking note of the timestamp information to select specific information to review. Copy the message and
other related information exactly as it appears on the console or in the system log.
%IM-0-EVENT_LIBRARY :
Explanation

An event facility initialization or maintenance function failed. This could be due to a software defect or system resource
exhaustion.
Recommended Action

In most cases, the problem can be corrected by reloading the impacted hardware using the hw-module [slot | subslot] slot-number
reload command. If the reload fails to correct the problem, collect the output of the error message, the logs, and the output
of show tech-support and provide the gathered information to a Cisco technical support representative.
%IM-2-INVALID_ACT_MSG : Virtualization Service[chars]
Explanation

The virtualization service activate message was received, however, the data it contained could not be interpreted
Recommended Action

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and
scan them for the cause.
%IM-2-INVALID_DEACT_MSG : Failed to process virtualization service deactivate message
Explanation

The virtualization service deactivate message was received, however, the data it contained could not be interpreted
Recommended Action

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and
scan them for the cause.
%IM-2-ALLOC_VIRT_INST_RCS : Virtualization Service[chars]
Explanation

A memory allocation request failed to allocate a data structure required to activate the virtualization service.
Recommended Action

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and
scan them for the cause.
%IM-2-START_FAILED : Virtualization Service[chars]
Explanation

The named virtualization service failed to start.
Recommended Action

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and
scan them for the cause.
%IM-2-VIRT_INST_MEMORY : Virtualization Service[chars]
Explanation

The virtualization service requires physical memory in excess of the free memory available to virtualization services.
Recommended Action

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and
scan them for the cause.
%IM-2-VIRT_INST_DISK : Virtualization Service[chars]
Explanation

The virtualization service requires Disk Storage in excess of the Free Disk Storage available to virtualization services.
Recommended Action

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and
scan them for the cause.
%IM-2-MEMORY_LIMIT : Virtualization Service[chars]
Explanation

The virtualization service machine definition file is requesting more memory than the system has available for virtualization
services.
Recommended Action

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and
scan them for the cause.
%IM-2-VCPU_LIMIT : Virtualization Service[chars]
Explanation

The virtualization service machine definition file is requesting more VCPUs than the system has reserved for virtualization
services.
Recommended Action

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and
scan them for the cause.
%IM-2-DISK_IMAGE_PATH : Virtualization Service[chars]
Explanation

The virtualization service machine definition file contains an invalid disk image path for one of the disk devices. This may
be a Harddisk, CDROM or USB storage device.
Recommended Action

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and
scan them for the cause.
%IM-2-VIRT_INST_LOG_UNTHROTTLE : Failed to unthrottle the log for virtualization service [chars]
Explanation

The named virtualization service had sent overwhelming sys log messages and its log had been throttled as a result, but system
has failed to unthrottle it for some reason.
Recommended Action

For debugging collect the iox-manager logs and scan them for the cause.
%IM-2-VIRT_INST_STATE : Virtualization Service[chars]
Explanation

The named virtualization service has failed. It is no longer running either because the guest OS has failed, the guest OS
has shut down the machine or the emulator has failed.
Recommended Action

An attempt at restarting the virtualization service can be made from the IOS configuration by doing a no activate/activate.
For debugging collect the IOx-manager logs and scan them for the cause.
%IM-2-FIND_VIRT_INST_ENTRY : Failed to find virtualization service with id [int] in the IOx-manager list
Explanation

The virtualization service with the ID named could not be located in the IOx-manager list.
Recommended Action

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and
scan them for the cause.
%IM-5-AUX : Virtualization Service[chars]
Explanation

The AUX login to a virtualization service may allow the user access to system functions that may not have been tested or may
interact with the system in unintended ways. Use with caution.
Recommended Action

No action is required
%IM-2-INVALID_UNPROV_MSG : Failed to process virtualization service unprovision message
Explanation

The virtualization service unprovision message was received, however, the data it contained could not be interpreted
Recommended Action

Enable the IOx-manager trace logs and repeat the activation followed by deactivation and then unprovision of the virtualization
service. Collect the IOx-manager logs and scan them for the cause.
%IM-2-VCPU_INVALID : Virtualization Service[chars]
Explanation

The virtualization service machine definition file is requesting invalid VCPU value.
Recommended Action

Enable the IOx-manager trace logs and repeat the activation of the virtualization service. Collect the IOx-manager logs and
scan them for the cause.
%IM-2-CPUSHARES_LIMIT : Virtualization Service[chars]
Explanation

The virtualization service machine definition file is requesting more CPU shares than the system has available for virtualization
services.
Recommended Action

Deactivate any other virtualization services to free up CPU share resources and activate this virtualization service. If that
does not address the problem, then enable the IOx-manager trace logs and repeat the activation of the virtualization service.
Collect the IOx-manager logs and scan them for the cause.
%IM-2-INSTALL_FAILURE : Virtualization Service[chars]
Explanation

The installation of the virtualization service failed.
Recommended Action

Enable the IOx-manager trace logs and repeat the installation of the virtualization service. Collect the IOx-manager logs
and scan them for the cause.
%IM-2-INSTALL_MEDIA_RETRY : VM install media still unavailable.[chars]
Explanation

The install media was not detected. Waiting for udev to complete install media(harddisk) detection.
Recommended Action

After IOx-manager exceeds the maximum retry limit, verify if install media (harddisk) is accessible and retry the installation
again.
%IM-2-VIRT_INST_MGMT_INTERFACE : Virtualization service [chars] has no management interface defined but it is configured in
CLI.
Explanation

A management interface is configured but none is defined.
Recommended Action

Deactivate the virtualization service, remove the management interface configuration CLI, and reactivate the virtual-service.
%IM-2-GENERAL_FAILURE : Virtualization Service[chars]
Explanation

The named virtualization service has triggered the log. Please interpret the log in the context of the virtualization services.
Recommended Action

No action is required
%IM-3-SDWRAP_ERR : Description: [chars], errcode: [dec]
Explanation

Debug infrastructure error
Recommended Action

Collect the IOx-manager logs and scan them for the cause.
%IM-3-PSS_ERR : Purpose: [chars], URI: [chars], errcode: [dec]
Explanation

Persistent Storage Service handling error
Recommended Action

Collect the IOx-manager logs and scan them for the cause.
%IM-3-PSS_SNAPSHOT_ERR : Source URI: [chars], Destination URI: [chars], errcode: [dec]
Explanation

Persistent Storage Service snapshot error
Recommended Action

Collect the IOx-manager logs and scan them for the cause.
%IM-2-NETWORK_CONFIG_ERROR : Virtualization Service[chars]
Explanation

A network configuration error has been detected for the named virtualization service.
Recommended Action

No action is required
%IM-2-INSTALL_LOG : [chars] [chars] [chars] [chars]
Explanation

The installation log of the named virtualization service, is to provide more information about long running operation, that
could affect the control of CLI
Recommended Action

No action is required
%IM-2-UPGRADE_LOG : [chars] [chars] [chars] [chars]
Explanation

The upgrade log of the named virtualization service, is to provide more information about long running operation, that could
affect the control of CLI
Recommended Action

No action is required
%IM-2-INSTALL_STATE : [chars] ‘[chars]'[chars] [chars]
Explanation

The installation state of the named virtualization service has changed as notified by IOx-manager.
Recommended Action

In the failed case, check IOx-manager’s logs for the cause of the failure. In the successful case, this notification can be
ignored.
%IM-2-UNINSTALL_ALL_VMS : All Virtualization Services are being uninstalled [chars][chars] [chars]
Explanation

All virtualization services are being uninstalled by IOx-manager.
Recommended Action

Examine the reason given as to why all virtualization services are being uninstalled for more information. If the reason indicated
is due to some error condition, check IOx-manager’s logs for the cause of the failure.
%IM-2-ACTIVATION_STATE : [chars] ‘[chars]’ [chars] [chars]
Explanation

The activation state of the named virtualization service has changed as notified by IOx-manager.
Recommended Action

In the failed case, check IOx-manager’s logs for the cause of the failure. In the successful case, this notification can be
ignored.
%IM-4-WATCHDOG_TIMER : [chars] ‘[chars]’ [chars] [chars]
Explanation

The watchdog timer configured for the named virtual service has expired.
Recommended Action

Check any logs produced by the virtualization service to determine the cause.
%IM-2-HA_SYNC_ERR : [chars] ‘[chars]’ [chars]
Explanation

The ha-sync persistent storage disk for the virtualization service cannot be watched for sync to standby RP.
Recommended Action

Collect the IOx-manager logs and scan them for the cause.
%IM-2-DEACT_FOR_ISSU : [chars] Max ([int]s)
Explanation

An ISSU event is pending. Any active VMs will be automatically deactivated to allow ISSU preprocessing to validate the environment.
Any ISSU-deactivated VMs will be automatically restarted if the ISSU is cancelled.
Recommended Action

None. Allow the ISSU to continue and the VMs will restart when the ISSU completes or cancel the ISSU and IOx-manager will
automatically
%IM-2-RESET_FORCE : Virtualization Services non-recoverable reset command processed
Explanation

A ‘virtualization service reset force’ command has been entered and processed. This action initiates a cleanup of last resort.
Occasionally a VM will get into an unrecoverable state that prevents it from activating but also from uninstalling. This is
a rare event but when it happens the only resort may be to remove the .conf control file and reboot, which forces a cleanup
of all previously installed VM files and artifacts. Note that once this command is used, current VMs are considered to be
in an unstable or unpredictable state, and all future install, uninstall, upgrade, and activation commands will be blocked.
Recommended Action

Once the command is entered and accepted, there is no recourse but to restart the system.
%IM-2-MOVE_STATE : [chars] ‘[chars]’ [chars] [chars]
Explanation

The move of the core or log file of the named virtualization service has as been successful or failed as notified by IOx-manager.
Recommended Action

In the failed case, check IOx-manager’s logs for the cause of the failure. In the successful case, this notification can be
ignored.
%IM-2-RSYNC_STATE : [chars] [chars] [chars] [chars]
Explanation

IOx-manager tries to remote sync the virtual-instance configuration file and the OVA repository to all online nodes. If rsync
fails even after consecutive retries, this notification would be raised.
Recommended Action

In the failed case, check IOx-manager’s logs for the cause of the failure. Check for the rsync error code and root cause the
same.
%IM-2-HA_SYNC_THREAD_STATE : HA remote sychronize thread has failed and exited.
Explanation

IOx-manager tries to remote sync the OVA repository to all online nodes using a separate thread. If that thread fails, this
notification would be raised.
Recommended Action

In the failed case, check IOx-manager’s logs for the cause of the failure. Check for the pthread error msg and root cause
the same.
%IM-2-HA_STATE : [chars] [chars] [chars] [chars]
Explanation

IOx-manager tries to detect the role/slot of various nodes on HA events from the platform. If any of those event callbacks
fail, this notification would be raised.
Recommended Action

In the failed case, check IOx-manager’s logs for the cause of the failure. Check for the HA event error msg and root cause
the same.
%IM-2-HA_SWITCHOVER_STATE : [chars] [chars] [chars] [chars]
Explanation

IOx-manager HA switchover state related messages for a virtual-service whilst it is being recovered on newly active RP after
a HA switchover.
Recommended Action

In the failed case, check IOx-manager’s logs for the cause of the failure. Check for the HA event error msg and root cause
the same.
%IM-4-HA_SYNC_NEEDED : If using the guest shell, please use ‘guestshell sync’ if you want to preserve state on standby in
case of supervisor switchover
Explanation

Message notifying user that he needs to manually synchronize the Virtualization service contents to standby supervisor in
order to preserve these contents in case of a supervisor switchover. Currently only applicable to the guest shell
Recommended Action

User can type the ‘guestshell sync’ command on active supervisor to synchronize it’s contents to the standby supervisor if
desired.
%IM-2-RESIZE_OPER_STATE : Virtualization service ‘[chars]’ [chars][chars] to ‘[int]’ [chars]
Explanation

IOx-manager attempts to resize various VM parameters like rootfs size, CPU share, memory if requested by user. Success/failure
status messages for these resize operations are communicated by this syslog.
Recommended Action

In the failed case, check IOx-manager’s logs for the cause of the failure. Check for the HA event error msg and root cause
the same.
%IM-2-GUESTSHELL_ENABLED : The guest shell has been enabled. The command ‘[chars]’ may be used to access it, ‘[chars] destroy’
to remove it.
Explanation

Informs the user that the guest shell virtualization service has been enabled (which is done by default).
Recommended Action

The user may use or remove the guest shell with the commands specified.
%IM-5-PERMISSION_DENIED : Virtualization Service ‘[chars]’ is not owned by client IOSd
Explanation

An attempt was made to modify a virtual-service that is not owned by by the client. The request was rejected.
Recommended Action

No action is required.
%IM-2-IOX_INST_CRIT : IOX SERVICE [chars] LOG: [chars]
Explanation

The named virtual service has triggered the log. Please interpret the log in the context of the virtual services.
Recommended Action

No action is required
%IM-3-IOX_INST_ERR : IOX SERVICE [chars] LOG: [chars]
Explanation

The named IOX service has triggered the log. Please interpret the log in the context of the IOX services.
Recommended Action

No action is required
%IM-4-IOX_INST_WARN : IOX SERVICE [chars] LOG: [chars]
Explanation

The named IOX service has triggered the log. Please interpret the log in the context of the IOX services.
Recommended Action

No action is required
%IM-5-IOX_INST_NOTICE : IOX SERVICE [chars] LOG: [chars]
Explanation

The named IOX service has triggered the log. Please interpret the log in the context of the IOX services.
Recommended Action

No action is required
%IM-6-IOX_INST_INFO : IOX SERVICE [chars] LOG: [chars]
Explanation

The named IOX service has triggered the log. Please interpret the log in the context of the IOX services.
Recommended Action

No action is required
%IM-7-IOX_INST_DEBUG : IOX SERVICE [chars] LOG: [chars]
Explanation

The named IOX service has triggered the log. Please interpret the log in the context of the IOX services.
Recommended Action

No action is required
%IM-2-IOX_INST_LOG_UNTHROTTLE : Failed to unthrottle the log for IOX service [chars]
Explanation

The named IOX service had sent overwhelming sys log messages and its log had been throttled as a result, but system has failed
to unthrottle it for some reason.
Recommended Action

For debugging collect the ioxman logs and scan them for the cause.
%IM-6-IOX_RECONCILE_INFO : App-hosting application reconcile process [chars]
Explanation

Indicates stage of reconcile (application recovery) process.
Recommended Action

No action is required
%IM-6-IOX_START_INFO : [chars] cannot be started because it is not installed
Explanation

Indicates starting an app before installation.
Recommended Action

No action is required
%IM-6-IOX_START_SUCCESS : [chars] is in RUNNING state
Explanation

Indicates starting an app after installation.
Recommended Action

No action is required
%IM-6-IOX_START_FAIL : [chars] failed to start
Explanation

Indicates starting an app after installation.
Recommended Action

No action is required
%IM-6-START_MSG : app-hosting: [chars]
Explanation

Message for starting an app.
Recommended Action

In the failed case, check Ioxman’s trace log for the cause of the failure. In the successful case, this notification can be
ignored.
%IM-6-INSTALL_MSG : app-hosting: [chars]
Explanation

Message for installing an app.
Recommended Action

In the failed case, check Ioxman’s trace log for the cause of the failure. In the successful case, this notification can be
ignored.
%IM-6-ACTIVATE_MSG : app-hosting: [chars]
Explanation

Message for activating an app.
Recommended Action

In the failed case, check Ioxman’s trace log for the cause of the failure. In the successful case, this notification can be
ignored.
%IM-6-DEACTIVATE_MSG : app-hosting: [chars]
Explanation

Message for deactivating an app.
Recommended Action

In the failed case, check Ioxman’s trace log for the cause of the failure. In the successful case, this notification can be
ignored.
%IM-2-IOX_ENABLEMENT : IOX is ready.
Explanation

Message for IOX enablement.
Recommended Action

No action is required
%IM-6-UPGRADE_MSG : app-hosting: [chars]
Explanation

Message for upgrading an app.
Recommended Action

In the failed case, check Ioxman’s trace log for the cause of the failure. In the successful case, this notification can be
ignored.
%IM-6-VERIFICATION_MSG : app-hosting: [chars]
Explanation

Message for signature verification
Recommended Action

In the failed case, check Ioxman’s trace log for the cause of the failure. In the successful case, this notification can be
ignored.

IMGR

%IMGR-0-FIPS_FMFP_BYPASS_TEST : NIST bypass test failed for [chars].
Explanation

Forwarding Manager IPsec component detected a discrepancy when adding or deleting a security sensitive object. This could
be due to a hardware or software resouce limitation or a software defect.
Recommended Action

Check the logs for information on the relevant object download states. Remove the object or a parent object in question. If
the problem persists reboot the forwarding processor (ESP).
%IMGR-6-FIPS_FMFP_CRNG_TEST : continuous [chars]approved RNG test failed.
Explanation

Forwarding Manager IPsec component detected two identical random number sequences. This could be due to a hardware mulfunction
or a software defect.
Recommended Action

If the problem persists reboot the forwarding processor (ESP).
%IMGR-6-FIPS_FMFP_OLAP_TEST : FIPS-approved RNG key seed and state overlap.
Explanation

Forwarding Manager IPsec component detected an overlap in FIPS-approved RNG key seed and state. This could be due to a hardware
mulfunction or a software defect.
Recommended Action

If the problem persists reboot the forwarding processor (ESP).
%IMGR-6-FIPS_FMFP_KAT_TEST : power up cryptographic self-test didnot run to completion: [chars].
Explanation

Forwarding Manager power up known answer self-test (KAT) failed. This could be due to a hardware malfunction or a software
defect.
Recommended Action

If using ipsec, reboot the forwarding processor (ESP).
%IMGR-0-FIPS_CPP_CLIENT_BYPASS_TEST : CPP Client FIPS bypass test failed for [chars].
Explanation

Forwarding Manager CPP client IPSEC bypass test failed. This could be due to a hardware malfunction or a software defect.
Recommended Action

If the problem persists reboot the forwarding processor (ESP).
%IMGR-6-FIPS_FMFP_N2_ERR_FAIL : Cryptographic coprocessor non-critical failure: [chars].
Explanation

Cryptographic coprocessor non-critical operation failed. If the problem persists reboot the forwarding processor(ESP)
Recommended Action

If the problem persists reboot the forwarding processor (ESP).
%IMGR-0-FIPS_FMFP_N2_SEVERE_ERR_FAIL : Cryptographic coprocessor severe failure: [chars].
Explanation

Cryptographic coprocessor critical operation failed. Further data processing on ESP is halted
Recommended Action

forwarding processor (ESP) is rebooted automatically. no action needed
%IMGR-6-FMFP_KAT_TEST_RESULT : crypto self-test for algorithm: ([chars] … passed).
Explanation

Forwarding Manager power up known answer self-test (KAT) success. This is not an error message
Recommended Action

No action needed.
%IMGR-6-FMFP_IPSEC_MIN_MTU_INFO : MTU smaller than minimum IPSec MTU, [chars].
Explanation

Minimum MTU supported by crypto processor is 256B, MTU lower than 256B is set to 256B
Recommended Action

No action needed
%IMGR-6-FMFP_IPSEC_UNSUPPORTED_CIPHER : Cipher [chars] is not supported on this ESP.
Explanation

This ESP does not support this IPSec cipher
Recommended Action

No action needed
%IMGR-6-FMFP_IPSEC_CRYPTO_CTRL_THROTTLED : IPsec Control Plane Overload Crypto Device: [chars].
Explanation

This ESP crypto device is overloaded.
Recommended Action

May need to config platform ipsec control-plane medium|heavy
%IMGR-6-FMFP_CRYPTO_DEVICE_BUSY : All Crypto Device cores are busy with data packets.
Explanation

All ESP crypto device are busy.
Recommended Action

May need to lower crypto traffic rate.

INDXOBJ

%INDXOBJ-3-INTERRUPT : index object routine [chars] called from interrupt context
Explanation

inappropriate index object routine called from interrupt routine.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%INDXOBJ-3-ADD_ERROR : index add for [chars] failed: [chars]
Explanation

index object routine error
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

INFRA

%INFRA-3-INVALID_GPM_ACCESS : Invalid GPM [chars] at [hex] HAL start [hex] HAL end [hex] INFRA start [hex] INFRA [hex] NET
[hex], MSGDEF_LIMIT_MEDIUM
Explanation

Processing packet went beyond valid packet data, packet was possibly invalid, ppe info and encrypted pkt dump follow
Recommended Action

LOG_STD_ACTION
%INFRA-3-INVALID_GPM_ACCESS_INFO : [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex] [hex]
[hex]
Explanation

Registers associated with previous exception error
Recommended Action

LOG_STD_ACTION
%INFRA-3-INVALID_GPM_ACCESS_DATA :
Explanation

Packet associated with previous exception error The packet data has been encrypted
Recommended Action

LOG_STD_ACTION

INSTALL

%INSTALL-5-OPERATION_START_INFO : Started [chars] package [chars]
Explanation

This message is used to indicate the beginning of operations.
Recommended Action

No action required. This is not an error, it is an indication that the system is starting the operation.
%INSTALL-5-OPERATION_COMPLETED_INFO : Completed [chars] package [chars]
Explanation

This message is used to indicate the completion of operations.
Recommended Action

No action required. This is not an error, it is an indication that the system completed the operation.
%INSTALL-3-OPERATION_ERROR_MESSAGE : Failed to [chars] package [chars], Error: [chars]
Explanation

This message is used to inform the failure reason.
Recommended Action

Please refer to the error message to analyze the cause of failure.
%INSTALL-5-INSTALL_START_INFO : Started [chars] [chars] [chars]
Explanation

This message is used to indicate the beginning of install operations.
Recommended Action

No action required. This is not an error, it is an indication that the system is starting this operation.
%INSTALL-5-INSTALL_COMPLETED_INFO : Completed [chars] [chars] [chars]
Explanation

This message is used to indicate the completion of install operations.
Recommended Action

No action required. This is not an error, it is an indication that the system completed this operation.
%INSTALL-3-INSTANT_ERROR_MESSAGE : Error Message: [chars]
Explanation

This message is used to send a instant erorr message.
Recommended Action

No action required.
%INSTALL-5-INSTALL_AUTO_ABORT : Install auto abort timer expired: initiating abort
Explanation

An install operation has been aborted because the auto abort timer has expired.
Recommended Action

No user action is needed. If you want to commit the ISSU upgrade, redo the upgrade. Otherwise, this is an informational message
only.
%INSTALL-5-INSTALL_AUTO_ABORT_TIMER_PROGRESS : Install auto abort timer will expire in [dec] seconds
Explanation

An install operation will be aborted after specified seconds of time.
Recommended Action

No user action is needed. If you want to commit the ISSU upgrade, redo the upgrade. Otherwise, this is an informational message
only.

INTERCHASSIS_REDUNDANCY

%INTERCHASSIS_REDUNDANCY-4-STDBY_PRESENT : Removal of standby RP in location [chars] is recommended for inter-chassis redundancy
configuration
Explanation

Removal of standby RP from the chassis is recommended for inter-chassis redundancy
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

INTERFACE_API

%INTERFACE_API-4-BADSWIDB : [chars] may not be referencing the correct swidb
Explanation

An internal software error occurred.
Recommended Action

If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search
of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%INTERFACE_API-4-BADPAKINPUT : pak->if_input is not initialized
Explanation

An internal software error occurred.
Recommended Action

If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search
of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%INTERFACE_API-1-NAMESTRTOOLONG : Interface name [chars].[int] exceeded maximum allowed length [dec]
Explanation

An internal software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%INTERFACE_API-3-NOADDSUBBLOCK : The [chars] subblock named [chars] was not added to [chars]
Explanation

A software error has occured, this message is displayed when IDB subblocks cannot be added.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%INTERFACE_API-3-INVALIDSUBBLOCKPARAMETERS : Invalid subblock parameters for [chars] were supplied.
Explanation

An internal software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show idb and show tech-support
commands to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit BUG_TOOLKIT
. If you still require assistance, open a case with the Technical Assistance Center via the Internet TAC_CASE_OPEN , or contact
your Cisco technical support representative and provide the representative with the gathered information.
%INTERFACE_API-3-SUBNUMDBERR : subnum [hex] error in [chars]
Explanation

A software error has occured, this message is displayed when a problem has occured with a sub_number db.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%INTERFACE_API-1-NOMORESWIDB : No more SWIDB can be allocated, maximum allowed [dec]
Explanation

No more Interfaces can be created because the maximum number of SWIDB allowed for this platform has been reached
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%INTERFACE_API-1-NOMORE_HASWIDBS : No more IDBS can be created. The maximum allowed numbers, [int], has been reached on Standby
Please force redundancy mode to RPR if full Active Capacity, [int], is needed
Explanation

No more Software IDB numbers can be Created. The maximum allowed numbers has been reached for this High Available System.
Recommended Action

%INTERFACE_API-1-NOMOREHWIDBNUMBERS : No more hardware IDB numbers can be issued. The maximum allowed numbers, [dec], has
been reached for this platform.
Explanation

No more hardware IDB numbers can be issued. The maximum allowed numbers has been reached for this platform.
Recommended Action

In addition to the following, copy the information from show idb. LOG_STD_ACTION
%INTERFACE_API-1-NOMORESWIDBNUMBERS : No more software IDB numbers can be issued. The maximum allowed numbers, [dec], has
been reached for this platform.
Explanation

No more software IDB numbers can be issued. The maximum allowed numbers has been reached for this platform.
Recommended Action

In addition to the following, copy the information from show idb. LOG_STD_ACTION
%INTERFACE_API-4-BADPAKOUTPUT : pak->if_output is not initialized on interface [chars]
Explanation

An internal software error occurred.
Recommended Action

If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search
of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%INTERFACE_API-4-BADPOINTER : Function [chars] detected an invalid [chars] pointer of %08lX, ignoring
Explanation

A software error has occurred, this message is displayed when an invalid pointer is detected.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%INTERFACE_API-3-NODESTROYSUBBLOCK : The [chars] subblock named [chars] was not removed
Explanation

A software error has occured, this message is displayed when IDB subblocks cannot be removed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%INTERFACE_API-3-CANNOTGETMTU : Error [dec] received while getting MTU: [chars]. Using default [int]
Explanation

A software error has occurred while attempting to retrieve the MTU value from the interface.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%INTERFACE_API-3-NOSUBBLOCK : [chars] subblock does not exist on interface [chars]
Explanation

An internal software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%INTERFACE_API-4-TBLERROR : A error occurred while using the Index Table utility for [chars].
Explanation

A software error has occurred; this message is displayed when an Index table feature could not be used successfully.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%INTERFACE_API-3-BADIDBSTATUSCHANGECALL : Invalid function call at interrupt level.
Explanation

An internal function was illegally called at interrupt level. This error might be caused by incorrectly coded creation or
deletion of an interface, or during an OIR operation.
Recommended Action

Perform a search of the Bug Toolkit, BUG_TOOLKIT . If you still require assistance, copy the error message exactly as it appears
on the console or in the system log. Issue the show tech command and copy the output. If you performed any actions before the error message appeared, make a note of this. Open a
case with the Technical Assistance Center via the Internet TAC_CASE_OPEN , or contact your Cisco technical support representative
and provide the representative with the gathered information.
%INTERFACE_API-3-IFNUMTOIDBERROR : Error occurred while using the ifnum to idb table for interface [chars], if number [dec],
during [chars]
Explanation

A software error has occurred. This message is displayed when an operation on the if_number to idb mapping table could not
be performed successfully.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%INTERFACE_API-3-HWIDBQREENTRANT : [chars] in progress of being inserted/removed, ignoring new request to [chars]
Explanation

A software error has occurred while attempting to insert or remove the interface into the system as there’s already another
attempt in progress to insert or remove this interface. The first attempt must complete before a new attempt can be started.
The user should retry this operation at a later time.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOMD_INFRA

%IOMD_INFRA-4-BADPOINTER : Function [chars] detected an invalid [chars] pointer of %08lX, ignoring
Explanation

A software error has occurred, this message is displayed when an invalid pointer is detected.
Recommended Action

Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system
log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using
the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case,
or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOMD_INFRA-3-IPCSENDFAIL : IOMD failed to send a message [chars] reason: [chars]
Explanation

IOMD failed to send message to the RP
Recommended Action

Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system
log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using
the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case,
or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOMD_INFRA-3-IPCALLOCFAIL : Failed to allocate IPC buffer [chars]
Explanation

The IM failed to allocate a buffer for communication with RSP
Recommended Action

Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system
log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using
the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case,
or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOMD_INFRA-6-TDLMSG_INCOMPATIBLE : Failed to copy message [chars] to buffer, not allowed for current domain.
Explanation

Failure to marshal a message indicates an incompatibility with the intended recipient.
Recommended Action

Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system
log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using
the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case,
or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOMD_INFRA-3-INVALID_SLOT_NUM : An invalid slot number is specified in one of the internal APIs. slot=[dec] max_slot=[dec]
Explanation

Invalid slot number to find the TDL domain
Recommended Action

Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system
log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using
the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case,
or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOMD_INFRA-3-INVALID_BAY_NUM : An invalid bay number is specified in one of the internal APIs. bay=[dec] max_bay=[dec]
Explanation

Invalid bay number to find the TDL domain
Recommended Action

Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system
log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using
the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case,
or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOMD_INFRA-4-INTR_OVER_LIMIT : IOMd main thread disabled interrupt for [int] msec.
Explanation

IOMd main thread process disabled interrupt too long
Recommended Action

Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system
log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using
the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case,
or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOMD_INFRA-3-INTR_EVENT : IOMd fast thread event ([dec]).
Explanation

IOMd fast thread event
Recommended Action

Examine the logs for IOMD. If the problem persists, copy the message exactly as it appears on the console or in the system
log. Research and attempt to resolve the issue using the tools and utilities provided at http://www.cisco.com/tac. With some messages, these tools and utilities will supply clarifying information. Search for resolved software issues using
the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case,
or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOMD_INFRA-3-I2C_WRITE : An I2C write has failed because [chars]
Explanation

An I2C write has failed. This could be due to a hardware or software defect.
Recommended Action

Note the time of the error message and examine the logs for I2C errors. If the logs provide information about a correctable
problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error
message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.
%IOMD_INFRA-3-I2C_READ : An I2C read has failed because [chars]
Explanation

An I2C read has failed. This could be due to a hardware or software defect.
Recommended Action

Note the time of the error message and examine the logs for I2C errors. If the logs provide information about a correctable
problem, correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error
message, the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.
%IOMD_INFRA-3-LINECARDDIAGSFAILED : Module [chars] in Slot [dec] failed online diagnostics. Please use ‘show post’ for more
details
Explanation

Online Diag has failed. This could be due to a hardware or software defect.
Recommended Action

Note the time of the error message and examine the logs for errors. If the logs provide information about a correctable problem,
correct the problem. If the problem is not correctable or the logs are not helpful, collect the output of the error message,
the logs, and the output of show tech-support and provide the gathered information to a Cisco technical support representative.

IOSD

%IOSD-3-BIPC_REJECT : Could not accept ipc connection: [chars]
Explanation

This error occurs if shell-manager has denied an ipc connection request from IOS.
Recommended Action

Check the connection request parameters.
%IOSD-3-TDL_PROPERTIES : Could not set message properties for connection: [chars]
Explanation

This error occurs if shell-manager is unable to set message properties for the IOS-sman connection
Recommended Action

Check the connection request parameters.

IOSD_INFRA

%IOSD_INFRA-6-IFS_DEVICE_OIR : Device [chars] [chars]
Explanation

USB inserted/removed
Recommended Action

No action is required.
%IOSD_INFRA-3-IFS_DEVICE_DETECT_FAIL : Device [chars] [chars]
Explanation

USB detection failed
Recommended Action

USB Insertion could not be handled completely. Device needs to be removed and re-inserted

IOSXE_APS through IOSXE_FMANRP_CCE

  • IOSXE_APS

  • IOSXE_CSLIFS

  • IOSXE_CXSC

  • IOSXE_DNS

  • IOSXE_EPA

  • IOSXE_ETHERCHAN

  • IOSXE_EZMENU

  • IOSXE_FMANRP

  • IOSXE_FMANRP_ADJ

  • IOSXE_FMANRP_CCE

IOSXE_APS

%IOSXE_APS-3-GROUP_CONFIG_FAIL : Group change for interface [chars] Group [dec] failed
Explanation

Group change for interface has failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_APS-3-CONFIG_FAIL : config change for interface [chars] Group [dec] failed
Explanation

config for an interface to forwarding plane has failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_APS-3-FLOWIDDELETIONFAILED : Deletion of APS flow ID with manager failed for interface [chars] group [dec]
Explanation

An unexpected condition has occurred that deletion of APS flow ID.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_APS-3-FLOWIDALLOCFAILED : Allocation of APS flow ID with manager failed for interface [chars] group [dec]
Explanation

An unexpected condition has occurred that allocation of APS flow ID. failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_APS-3-PAIR_CONFIG_FAIL : Pair config for interface [chars] Group [dec] failed
Explanation

Pair config for interface has failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_APS-3-CCCONFIGFAILED : Pair config for interface [chars] Group [dec] failed
Explanation

Pair config for interface has failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_APS-3-FLOWCONFIGTOCCFAILED : Flow id to cc for interface [chars] Group [dec] failed
Explanation

Flow id to cc for an interface has failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_APS-3-DOWNLOADFAIL : Unable to download [chars] message to [chars]
Explanation

An unexpected condition has occurred which resulted in a configuration not being sent to the reported process.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_CSLIFS

%IOSXE_CSLIFS-3-ERROR_SETTING : Error setting default file system ([dec])
Explanation

There is an error happened after calling function ifs_set_default_directory
Recommended Action

Check the csl filesystem

IOSXE_CXSC

%IOSXE_CXSC-3-ALLOC : Failed to allocate message for proposition
Explanation

When attempting to program the dataplane with a CXSC proposition object, there was no enough memory to allocate the message.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_CXSC-3-MESSAGE : Failed to send message for proposition
Explanation

When the proposition was being prepared for sending to the data plane, there was an error.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_CXSC-3-ACTION : Unknown proposition action ([dec])
Explanation

When the proposition was being sent to the data plane, the action was unknown error.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_CXSC-3-BAD_PROPOSITION : Proposition obj corrupt
Explanation

When the proposition was being sent to the data plane, the object itself is corrupt.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_CXSC-3-BAD_SUMMARY : Summary obj corrupt
Explanation

When the proposition summary was being sent to the data plane, the object itself is corrupt.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_CXSC-4-DUAL_RP_UNSUPPORTED : Dual RPs are not supported in conjunction with CXSC
Explanation

CXSC is not supported in a dual RP environment. To resolve this warning, either unconfigure CXSC or remove the redundant Route
Processor.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_CXSC-3-RF_INIT : Failed to initialize CXSC Redundancy Facility client
Explanation

An unexpected condition occurred where the CXSC Redundancy Facility failed to initialize.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_CXSC-3-STILE_ACTIVATE : Failed to activate NBAR classification: ([dec])
Explanation

An unexpected condition occurred where the CXSC NBAR protocol classification failed to activate.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_CXSC-3-STATISTICS_ALLOCATION : Unable to allocate space for statistics
Explanation

During initialization, there was failure in the allocation of the memory to gather the statistics. It is non fatal, but after
seeing this message, the CXSC subsystem will not be able to gather statistics.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_CXSC-3-BAD_PROTOCOLPACK : Invalid Protocol Pack object
Explanation

When the Protocol Pack was being sent to the data plane, the object’s contents were invalid.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_CXSC-3-FILESYSTEM_ERR : FileSystem Error ([chars]): Unable to Copy File from [chars] to [chars]
Explanation

Unable to copy the NBAR Protocol Pack File to the file system for subsequent loading. The system will revert to the previously
loaded Protocol Pack.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_CXSC-3-INSUFFICIENT_ALLOC_IOSXE_VER : Insufficent memory allocated for IOSXE version String
Explanation

The input IOSXE Version String has insufficient memory to hold the IOSXE Version.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_CXSC-3-INSUFFICIENT_ALLOC_NBAR_VER : Insufficent memory allocated for NBAR Engine Version String
Explanation

The input NBAR Engine Version string has insufficient memory to hold the NBAR Engine Version.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_CXSC-3-PLATFORM_TYPE : Unrecognised platform type. CPU ID [dec]
Explanation

The platform that the cxsc service is being installed on is not recognised. The most likely cause is that this platform is
not supported.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_DNS

%IOSXE_DNS-3-UPDATE_FAILED : Update resolv.conf, vrf [chars], rc [dec]
Explanation

An unexpected condition has occurred while updating the DNS file
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_DNS-3-VRF_FAILED : Operation ([chars]) on /etc/netns/[chars], rc [dec]
Explanation

An unexpected condition has occurred while updating the DNS directory
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_EPA

%IOSXE_EPA-3-CREATION_FAILURE : slot=[dec] subslot=[dec], spa_type=[hex], lc_type=[hex].
Explanation

Failed to create a SPA object.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_EPA-3-ACT2_AUTHENTICATION_FAILURE : slot=[dec] subslot=[dec], spa_type=[hex], lc_type=[hex].
Explanation

ACT2 dev authentication Failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_EPA-3-NULL_EPASENSOR_PTR :
Explanation

Pointer to a DEVSENSOR object is NULL.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_EPA-3-NULL_PORT_PTR :
Explanation

Pointer to a PORT object is NULL.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_EPA-3-NULL_DEVPSEQ_PTR :
Explanation

Pointer to a DEVPSEQ object is NULL.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_EPA-3-NULL_DEVOBJ_PTR :
Explanation

Pointer to a DEVOBJ object is NULL.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_EPA-3-NULL_FPGA_PTR :
Explanation

Pointer to a FPGA object is NULL.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_EPA-3-NULL_EPA_PTR :
Explanation

Pointer to an EPA object is NULL.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_EPA-3-NULL_VSC_PHY_INFO_PTR :
Explanation

Pointer to a VSC PHY INFO object is NULL.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_EPA-3-NULL_VFT :
Explanation

Pointer to a DEVSENSOR object is NULL.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_EPA-3-UNSUPPORTED_XCVR : Transceiver type [chars] is not allowed on spa [chars], port [dec],
Explanation

This transceiver is not allowed on the SPA
Recommended Action

Consult the documentation and ensure supported transceivers are plugged into the SPA
%IOSXE_EPA-3-AUTONEG_CFG_ERR : interface [chars] autoneg state ‘[chars]’ is incompatible with transciever. Remove ‘[chars]’
to allow the transceiver.
Explanation

Autoneg Config is not compatible. Remove autoneg config on the interface to allow the transceiver
Recommended Action

Remove the negotiation auto config or reinsert the previously enabled transceiver.
%IOSXE_EPA-3-XCVR_EC_BWMISMATCH : Trasnsceiver bandwidth is incompatible with Port-channel[dec] allowed bandwidth. Remove
‘channel-group [dec]’ config for interface [chars] to allow the transceiver
Explanation

The interface port into which the transceiver is inserted is part of a Port-channel. The Port-channel has member links whose
bandwidth doesn’t match with the inserted transceier’s bandwidth. Since, port-channel cannot allow heterogenous bandwidth
links, this transceiver is not allowed in to the port.
Recommended Action

Remove the channel-group config for the port where transceiver is inserted or insert a transceiver whose bandwidth is compatible
with the port-channel bandwidth
%IOSXE_EPA-3-XCVR_PROHIBIT : Transceiver is prohibited to come online for interface [chars]
Explanation

XCVR is prohibited on the interface
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_ETHERCHAN

%IOSXE_ETHERCHAN-6-LINK_MTU : Interface [chars] MTU set to port-channel [chars] MTU [dec]
Explanation

The MTU for the interface mentioned in the message is changed to match the MTU configured on the port channel interface
Recommended Action

No action is required.
%IOSXE_ETHERCHAN-3-LINK_MTU_FAIL : Failure in changing MTU of interface [chars] to port-channel [chars] MTU
Explanation

The MTU for the interface mentioned in the message cannot be changed to match the MTU configured on the port channel interface
Recommended Action

Remove the link mentioned in the message from the port-channel group

IOSXE_FMANRP

%IOSXE_FMANRP-4-MSGDISPATCHNULL : TDL messages NULL from IOS.
Explanation

An unexpected condition has occurred while IOS trying to dispatch the TDL message handler functions for received TDL messages
from Forwarding Manager.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP-4-MSGDISPATCH : Unable to dispatch received TDL message ‘[chars]’ from Forwarding Manager. LUID: [chars]
Explanation

An unexpected condition has occurred while IOS trying to dispatch the TDL message handler functions for received TDL messages
from Forwarding Manager.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP-4-MSGIPCERR : Unable to process received IPC messages from Forwarding Manager, error: [chars].
Explanation

An unexpected condition has occurred while IOS trying to process received IPC message from Forwarding Manager.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP-3-EPOCHTDLMSGMARSHAL : Failed to copy epoch TDL message to IPC buffer, epoch number [dec]
Explanation

This operation to build a TDL messages for epoch message has failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP-3-MSGMARSHALERR : Unable to copy IPC messages into transport buffer. Message: [chars]
Explanation

An unexpected condition has occurred while IOS trying to copy IPC message to transport buffer in order to send the message
from IOSd to Forwarding Manager.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP-3-MSGENQERR : Unable to enqueue IPC messages to IOS IPC queue. Message: [chars].
Explanation

An unexpected condition has occurred while IOS trying to enqueue IPC message to IOS IPC queue in order to send the message
to Forwarding Manager.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP-4-MSGNONTDLSTATSERR : Unable to process received non-TDL stats message from Forwarding Manager, error: [chars]
([dec]).
Explanation

An unexpected condition has occurred while IOS trying to process received non-TDL stats message from Forwarding Manager.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_FMANRP_ADJ

%IOSXE_FMANRP_ADJ-3-NOADJ : Adjacency entry is null
Explanation

An unexpected condition has occurred which is due to the absence of an adjacency entry structure.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show adjacency command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_ADJ-3-NOFIBHWIDB : FIB Interface [chars] is null
Explanation

An unexpected condition has occurred which is due to the absence of a FIB interface structure.
Recommended Action

LOG_STD_SH_CMD_ACTION(show adj)
%IOSXE_FMANRP_ADJ-3-ENQUEFAIL : Unable to send [chars] [chars] message to Forwarding Manager Process
Explanation

An unexpected condition has occurred which resulted in a configuration not being sent to the Forwarding Manager Processs.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_ADJ-3-ENCSIZE : Invalid encap length [dec] which is larger than max allowed [dec] bytes
Explanation

An unexpected condition has occurred which is due to invalid adjacency encapsulation size being larger than the maximum value
allowed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_FMANRP_CCE

%IOSXE_FMANRP_CCE-4-CCE_STACK_LIMIT : Failed to create class [dec] filter list
Explanation

An operation to send a filter list to the forwarding processor for a particular class has failed due to a resource issue.
This may imply that the notification was dropped.
Recommended Action

LOG_STD_SH_CMD_ACTION(show class-map [type <class type> <name>])
%IOSXE_FMANRP_CCE-3-CCE_INVALID_FILTER_RELN : Invalid filter relation [int]
Explanation

An internal error occured when trying to build class-map information for one of the classes in a policy-map.
Recommended Action

LOG_STD_SH_CMD_ACTION(show policy-map [type <policy type> <name>])
%IOSXE_FMANRP_CCE-3-CCE_FILTER_OVERFLOW : Filter list overflow at type [chars]
Explanation

An internal error occured when trying to build class-map information for one of the classes in a policy-map.
Recommended Action

LOG_STD_SH_CMD_ACTION(show class-map [type <class type> <name>])
%IOSXE_FMANRP_CCE-3-CCE_CLASS_CREATE : Unable to create class [int].[int]
Explanation

An error occured when trying to create a class-map.
Recommended Action

LOG_STD_SH_CMD_ACTION(show policy-map [type <policy type> <name>])
%IOSXE_FMANRP_CCE-4-CCE_NESTED_CLASS_LIMIT : Nested class [dec] layers cannot exceed 4
Explanation

When configure nested classes as match statements, the total levels of nested classes cannot exceed 4 layers
Recommended Action

LOG_STD_SH_CMD_ACTION(show class-map [type <class type> <name>])

IOSXE_FMANRP_CEF through IOSXE_MEMPOOL_MIB

  • IOSXE_FMANRP_CEF

  • IOSXE_FMANRP_FPM

  • IOSXE_FMANRP_OBJID

  • IOSXE_FMANRP_OBJID2

  • IOSXE_FMANRP_RTMAP

  • IOSXE_FMANRP_URPF

  • IOSXE_FMANRP_ZONES

  • IOSXE_INFRA

  • IOSXE_LICENSE_POLICY_MANAGER

  • IOSXE_MEMPOOL_MIB

IOSXE_FMANRP_CEF

%IOSXE_FMANRP_CEF-3-NOFIB : FIB entry is null
Explanation

An unexpected condition has occurred which is due to the absence of a FIB entry structure.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show ip cef command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_CEF-3-NOFIBSB : FIB SB entry is null
Explanation

An unexpected condition has occurred which is due to the absence of a FIB SB entry structure.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show ip cef command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_CEF-3-NOFIBTABLE : FIB table is null
Explanation

An unexpected condition has occurred which is due to the absence of a FIB table structure.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show ip cef command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_CEF-3-NOFIBIDB : FIB interface is null
Explanation

An unexpected condition has occurred which is due to the absence of a FIB interface structure.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show ip cef command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_CEF-3-ENQUEFAIL : Unable to send [chars] [chars] message to Forwarding Manager Process
Explanation

An unexpected condition has occurred which resulted in a configuration not being sent to the Forwarding Manager Processs.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_CEF-4-UPDFRAGSTATSERR : Update IP Fragmentation statistics error
Explanation

An unexpected condition has occurred when updating fragmentation statistics
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_CEF-4-UPDREASSSTATSERR : Update IP Reassembly statistics error
Explanation

An unexpected condition has occurred when updating reassembly statistics
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_CEF-4-UPDSTATSERR : Update CEF statistics error
Explanation

An unexpected condition has occurred when updating cef statistics
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_CEF-3-ROUTEMSGMARSHAL : Failed to copy route essage to IPC buffer for prefix [chars]/[dec] — [chars]
Explanation

This operation to build a TDL messages for route download has failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_CEF-3-NOFIBPUSHCNT : FIB push counter is null
Explanation

An unexpected condition has occurred which is due to the absence of a FIB push counter structure.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show ip cef command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_CEF-3-NOFIBSIGNAL : FIB signal is null
Explanation

An unexpected condition has occurred which is due to the absence of a FIB signal structure.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show ip cef command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_CEF-3-NONATADDR : NAT address is null
Explanation

An unexpected condition has occurred which is due to the absence of an NAT address.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show ip alias command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_FMANRP_FPM

%IOSXE_FMANRP_FPM-4-INVALIDLENTYPE : Field length type in PHDF file is invalid
Explanation

An unexpected condition has occurred which is due to the invalid field length type in PHDF file.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_FPM-4-INVALIDMATCHTYPE : FPM match type is invalid [dec]
Explanation

An unexpected condition has occurred which is due to the invalid FPM match type in one of FPM class-map filter match entry
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_FPM-4-INVALIDACTION : FPM feature action is invalid [dec]
Explanation

An unexpected condition has occurred which is due to the invalid action type when trying to bind FPM action with target class
group.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_FPM-3-NOSTATUPDATE : Failed to update class-map statistics during periodic update
Explanation

A statistics update for a class-map has failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_FMANRP_OBJID

%IOSXE_FMANRP_OBJID-5-DUPCREATE : Duplicate forwarding object creation obj_handle [hex], type [int], existing obj_id [hex],
type [int]
Explanation

An unexpected condition has occurred which results in duplicate forwarding object creation.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_FMANRP_OBJID2

%IOSXE_FMANRP_OBJID2-3-DUPCREATE : Duplicate forwarding object creation obj_handle [hex], type [int], existing obj_id [hex],
type [int]
Explanation

An unexpected condition has occurred which results in duplicate forwarding object creation with different object types.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_FMANRP_RTMAP

%IOSXE_FMANRP_RTMAP-3-RTMAPNULL : The route-map structure for [chars] is null
Explanation

An unexpected condition has occurred which is due to the absence of a route-map data structure.
Recommended Action

show route-map
%IOSXE_FMANRP_RTMAP-4-UNKOWNCLIANT : Unknown client type [dec] received
Explanation

An unexpected known client type is received for route-map download.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_RTMAP-3-INVALID_LIST : NULL
Explanation

An internal list structure has been detected as invalid.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_RTMAP-3-RTMAP_UNSUPPORTED : Routemap ([chars]) contain unsupported match/set clause, ignored
Explanation

A map contains unsupported match or set clause
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_FMANRP_URPF

%IOSXE_FMANRP_URPF-4-NOV4SWIDB : v4 sub-interface is null
Explanation

An unexpected condition has occurred which is due to the absence of a v4 swidb structure.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show ip interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_URPF-4-NOV6SWIDB : v6 sub-interface is null
Explanation

An unexpected condition has occurred which is due to the absence of a v6 swidb structure.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show ipv6 interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_URPF-3-INVALIDIFHDL : Invalid interface handle [int] for interface (number= [int], swidb= [hex], name= [chars])
Explanation

An unexpected condition has occurred which is due to an invalid interface handle
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_URPF-4-UPDV4STATSERR : Update v4 URPF statistics error
Explanation

An unexpected condition has occurred when updating v4 URPF statistics
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show ip interface <name> command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_FMANRP_URPF-4-UPDV6STATSERR : Update v6 URPF statistics error
Explanation

An unexpected condition has occurred when updating v6 URPF statistics
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show ipv6 interface <name> command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_FMANRP_ZONES

%IOSXE_FMANRP_ZONES-3-NOSTATUPDATE : Failed to update zone-pair statistics during periodic update (zone [chars], class [int])
Explanation

A statistics update for a zone-pair has failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_INFRA

%IOSXE_INFRA-3-INVALID_ERRMSG : Error message type [dec] not defined
Explanation

Error message type used is not defined in IOSXE infrastruction
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-SHIM_INIT_WQ_FAIL : IOSXE shim layer initialization failed: Can not create receiving queues
Explanation

IOSXE IOS shim layer initialization of watched queue failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-SHIM_INIT_WQ_CHASFS_FAIL : IOSXE shim layer initialization failed: Can not create receiving chasfs watched
queue
Explanation

IOSXE IOS shim layer initialization of watched queue failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-SHIM_INIT_PROC_FAIL : IOSXE shim layer initialization failed: Dispatch process creation failed
Explanation

IOSXE IOS shim layer initialization creating dispatch process failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-SHIM_INIT_MEM_FAIL : IOSXE shim layer initialization failed: Memory initialization failed.
Explanation

IOSXE IOS shim layer initialization of memory failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-SHIM_NO_IPC_DISPATCH_HDL : IOSXE shim layer [chars] process message without IPC dispatch handler.
Explanation

IOSXE IOS shim layer has no ipc dispatch handler set
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-SHIM_RXMSG_NO_IPC_HDL : IOSXE shim layer without IPC handler for fd [dec], seqnum [dec].
Explanation

IOSXE IOS shim layer cannot find ipc handler
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-SHIM_INIT_TDL_FAIL : IOSXE shim layer initialization TDL Lib [chars] failed.
Explanation

IOSXE IOS shim layer initialization of TDL library
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-SHIM_INIT_DISPATCH_INIT_FAIL : IOSXE shim layer initialization, dispatch path init failed.
Explanation

IOSXE IOS shim layer initialization of TDL disatch path
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-INVALID_RUNTIME_IDX : Thread runtime index [dec] is not valid
Explanation

Export the thread’s running time failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-6-THEAD_SELECT_ERR : Inbound message or packet select error, [chars].
Explanation

Socket select operation error in threads
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-INJECT_HDR_LENGTH_ERR : Inject hdr size [int] exceeds limit
Explanation

Inject header length exceeds pak header space
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-INJECT_EMBEDDED_HDR_LENGTH_ERR : Can’t allot space needed for embedded inject hdr size [int] exceeds limit
Explanation

Can’t allot space needed for embedded inject header, exceeds pak header space
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-INJECT_NO_IF_OUTPUT_ERR : Output intf is NULL, [chars]
Explanation

Output intf is requred to proceed, else skip the feautre
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-4-PUNT_KEEPALIVE_LOG_ERR_INV_PARAM : Invalid parameter: [chars]
Explanation

Invalid parameter was passed when generating punt err log
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-4-PUNT_KEEPALIVE_LOG_ERR_GET_FILE_NAME : Failed to get file name: [chars]
Explanation

Could not form a file name when generating punt err logPunt keepalive log error seen
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-4-PUNT_KEEPALIVE_LOG_ERR_INV_FILE_ID : Invalid file descriptor: [dec]
Explanation

Invalid file descriptor was found when generating punt err log
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-PUNT_KEEPALIVE_LOG_ERR_OPEN_FILE : Failed to open file: [chars]
Explanation

Failed to open file when generating punt err log
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-4-PUNT_KEEPALIVE_LOG_ERR_CLOSE_FILE : Failed to close file with descriptor: [dec]
Explanation

Closing of file failed when generating punt err log
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-PUNT_KEEPALIVE_LOG_ERR_WRITE_TO_FILE : Write to file Id [dec] failed [dec] bytes, expected [dec] bytes
Explanation

Write to file failed when generating punt err log
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-PUNT_KEEPALIVE_LOG_ERR_ALLOC_TTY : Failed to allocate a tty
Explanation

Can’t allocate a TTY when generating punt err log
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-PUNT_KEEPALIVE_LOG_ERR_ALLOC_CSB : Failed to allocate a csb
Explanation

Can’t allocate a csb when generating punt err log
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-PUNT_KEEPALIVE_LOG_ERR_PARSE_CMD : Failed to parse command: [chars]
Explanation

Failed to parse a command when generating punt err log
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-4-PUNT_KEEPALIVE_LOG_ERR_GET_PROCID : Failed to get process id
Explanation

Can’t get identifier of the process generating punt err log
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-4-PUNT_KEEPALIVE_LOG_ERR_INV_PROCID : Invalid proc id [dec], expected [dec]
Explanation

Invalid process trying to generate punt err log
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-4-NO_PUNT_KEEPALIVE : Keepalive not received for [int] seconds
Explanation

Punt Inject keepalive message was not received
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-2-FATAL_NO_PUNT_KEEPALIVE : Keepalive not received for [int] seconds resetting
Explanation

Punt Inject keepalive message was not received
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-2-FATAL_PUNT_LINK_DOWN : Punt Inject link went down resetting
Explanation

Punt Inject link went down
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-INJECT_GSB_CTL_INIT_FAIL : Inject adjacency subblock init failed
Explanation

Adj subblock control or register failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-PUNT_ADDR_RES_ENCAP_ERR : Punted address resolution packet with unknown encap [chars]
Explanation

Punted packet for ARP/ND with encap not supported
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-PUNT_SVC_PROC_ERR : Punt service [chars] create failed
Explanation

Punt service process can not be created
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-VM_PAGE_TABLE_ERR : VM guarded page operation failed, address [hex], [chars]
Explanation

VM guarded page avl tree operation error
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-PUNT_SVC_TYPE_UNKNOWN : Punted packet with unknown service type [int]
Explanation

Punted pak with an unsupported service type
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-5-PUNT_SVC_CANT_ENQUEUE : Punted pak can’t be enqueued for service
Explanation

Punted pak enqueue failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-5-PUNT_SVC_INVALID_OPT_PKT : Invalid IPv4 options packet punted to RP
Explanation

Invalid IPv4 options packet dropped in RP
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-4-INJECT_TUN_NONIP_WARN : pak with linktype [chars] gets into non-ip tunnel
Explanation

IP/IPv6/MPLS packet should to go through GRE tunnel for non-IP payload
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-INJECT_FEATURE_ESS_ERR : ESS segment not found, type [dec] hdl [hex]
Explanation

Packets to be injected to an unsupported ESS segment
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-6-PROCPATH_CLIENT_HOG : IOS shim client ‘[chars]’ has taken %ld msec (runtime: %ld msec) to process a ‘[chars]’
message
Explanation

The specified IOSXE IOS shim client has taken too long to process a received IPC or chasfs message
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-6-AUXTHD_REQUEST : Too many outstanding requests for file system access
Explanation

Resource temporarily unavailable
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-APP_SESS_OPEN_FAILED : An attempt to open [chars] with handle number [dec] has failed ([dec])
Explanation

Application session between processes failed to estabish.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-CONSOLE_DBUG_DROP : System dropped [dec] bytes of console debug messages.
Explanation

Debugging messages are being generated faster than they can be displayed on the console. The messages can not be guaranteed
to be seen so this message replaces the lost messages.
Recommended Action

Consider using conditional debugging or turning off console logging.
%IOSXE_INFRA-3-PUNT_INCOMP_WRONG_ADJID : Punted address resolution packet linktype [chars], adj-id [dec] is with linktype
[chars]
Explanation

CPP needs to punt incomplete adjacency for resolution by specifying the adjacency-id, but the included adjacency-id does not
match the incomplete adjacency this packet triggered.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-IFS_EXTLINK_ADD_FAIL : Could not add filesystem [chars] to IFS links
Explanation

Attempt to add filesystem root to allow for links failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-IFS_UDEV_REMOVE_FAIL : Could not remove udev device [chars]
Explanation

Attempt to remove udev device failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-IFS_DFLT_FS_REG_FAIL : Unable to set [chars] as a default file system.
Explanation

IOSXE’s platform dependent code failed to register the default file system.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-IFS_INIT_HIDDEN_FAIL : IOSXE shim layer initialization failed: Can not create receiving queues
Explanation

IOSXE IOS shim layer initialization of hidden path watch failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-BSO_MSG_HDR_LENGTH_ERR : BSO message header length [int] is incorrect
Explanation

BSO message header length is incorrect
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-BSO_MSG_HDR_MSGTYPE_ERR : BSO message header msgtype [int] is incorrect
Explanation

BSO message header msgtype is incorrect
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-BSO_MSG_UNMARSHAL_ERR : BSO message unmarshalling has failed
Explanation

BSO message unmarshalling has failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-BSO_MSG_CACHE_ERR : BSO message query cache update error — [chars]
Explanation

BSO message query cache update error
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-4-BSO_MSG_RIB_WATCH_WARN : BSO message RIB watch start error
Explanation

BSO message RIB watch start error
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-RELOAD_INFO_SAVE_FAIL : Unable to save reload information: [dec]: [chars].
Explanation

IOSXE’s platform dependent code failed to save the reload information.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-SN_IPFRR_PROC_ERR : Static Nexthop IPFRR [chars] create failed
Explanation

SN IPFRR process can not be created
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-6-CONSOLE_ACTIVE : [chars]
Explanation

Indicates that the current instance of IOS is assuming active control of the console. This is informational.
Recommended Action

No action is required.
%IOSXE_INFRA-6-PLATFORM_RELOAD : [chars]
Explanation

Indicates that the current instance of IOS is being reset by the platform code. This is part of a normal reset sequence and
the message is informational.
Recommended Action

No action is required.
%IOSXE_INFRA-6-CHASFS_CLOCK_SET_FAIL : Failed to set Chasfs property on system time change
Explanation

Unable to set chasfs property on system time change
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-CYAN_API_ERROR : Failed to retrieve platform dependent value of [chars] (err=[dec])
Explanation

CYAN API function failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-6-SHIM_RXMSG_IPC_INFO : IOS shim layer process IPC msg for fd [dec], seq_num [dec], ipc_status [dec]
Explanation

Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-SHIM_IPC_NOT_PROCESSED : msg handler returned FALSE for IPC msg for fd [dec], seq_num [dec], service [chars]
Explanation

Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-SWIFT_ORCH_PROC_FAIL : IOSXE SWIFT Orchestrator process creation failed
Explanation

The SWIFT Orchestrator process could not be created
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-BAD_GLIBC_BUF_FREE : An IOS buffer is freed into GLIBC buffer pool, buffer blockmagic [hex], flags [hex]
Explanation

An IOS buffer is freed into GLIBC buffer pool.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-BIPC_MGS_ALLOC_FAIL : Allocating [dec] byte for IPC [chars] msg failed: out of memory
Explanation

system is out of memory
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-SOCKET_PEEK_ERR : Interrupt processing of Punt received packets over socket failed as peek of packet returned
error: [chars]
Explanation

Peek at incoming message hit error
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-GET_BUFFER_ERR : Interrupt processing of Punt received packets over socket failed to get a packet buffer for
len [dec]
Explanation

Failed to get a packet buffer from the specified pool.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-SOCKET_RECV_ERR : Interrupt processing of Punt received packets over socket failed as receive packet hit error:
[chars]
Explanation

Hit error when receives packet from a socket.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-SOCKET_SEND_ERR : Transmit packet to the socket hit error: [chars]
Explanation

Transmit a packet to another socket hit error.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-INJECT_HEADER_ERR : Transmit packet to the socket failed as packet header length is greater than datagram
size. It’s an incorrect packet and cannot proceed sending. header length is [dec], datagram size is [dec].
Explanation

Packet header length is wrong.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-IDB_CREATE_ERR : Failed to create IDB(Interface Descriptor Block) for Punt/Inject socket interface
Explanation

Creating an idb corresponding to an interface failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-MALLOC_FAST_ERR : Failed to allocate memory for Punt/Inject socket instance
Explanation

malloc_fast failed to allocate memory.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-IDB_INIT_ERR : Failed to initialize IDB(Interface Descriptor Block) for Punt/Inject socket interface
Explanation

Hit error when we initialize idb.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-PI_SOCKET_RAW_PRE_INIT_ERR : Punt/Inject socket pre-initialization(IDB creation) failed
Explanation

PI Socket Raw pre-initialization failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-PI_SOCKET_RAW_INIT_ERR : Punt/Inject socket initialization failed
Explanation

PI Socket Raw initialization failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-MCPRP_INIT_PUNTPATH_FD_ERR : Initializing the ipc control for the puntpath fd failed
Explanation

Initializing the ipc control for the puntpath fd failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_INFRA-3-LIIN_TUN_MSG_ERR : LIIN error — [chars] [chars] [dec]
Explanation

LIIN in Tunnel mode experiencing error
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_LICENSE_POLICY_MANAGER

%IOSXE_LICENSE_POLICY_MANAGER-2-CONFIG_NULL : [chars]: Configuration is unavailable
Explanation

License Configuration is undefined for this platform.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_LICENSE_POLICY_MANAGER-2-FEATURE_CONFIG_NULL : [chars]: Feature Configuration is unavailable
Explanation

Feature Configuration is undefined for this platform.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_LICENSE_POLICY_MANAGER-2-FEATURE_MALLOC_FAILED : [chars]: Policy Mgr Feature Registration struct malloc failed
Explanation

Memory allocation for Feature Registration Struct failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_LICENSE_POLICY_MANAGER-2-FEATURE_NAME_NULL : [chars]: Feature name is NULL
Explanation

License feature name string is NULL
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_LICENSE_POLICY_MANAGER-2-LIC_REG_FAILED : [chars]: Failed to register [chars] license feature, result = [hex]
Explanation

License Registration failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_LICENSE_POLICY_MANAGER-2-LIC_REQ_FAILED : [chars]: [dec]/[dec]: Lic request failed (idx:[dec]), feature=[chars], lic_cnt=[dec],
err=[dec]
Explanation

License Request failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_LICENSE_POLICY_MANAGER-2-LIC_REL_FAILED : [chars]: [dec]/[dec]: Lic release failed (idx:[dec]), feature=[chars], lic_cnt=[dec],
err=[dec]
Explanation

License Release failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_LICENSE_POLICY_MANAGER-2-LIC_REQ_GEN_FAIL : [chars]: [dec]/[dec]: Lic request failed
Explanation

License Request failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_LICENSE_POLICY_MANAGER-2-LIC_REL_GEN_FAIL : [chars]: [dec]/[dec]: Lic request failed
Explanation

License Release failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_LICENSE_POLICY_MANAGER-2-BAY_MALLOC_FAILED : [chars]: Policy Mgr Bay DB malloc failed for [dec]/[dec]
Explanation

Memory allocation for SPA/EPA failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_LICENSE_POLICY_MANAGER-2-IF_MALLOC_FAILED : [chars]: Policy Mgr IF DB malloc failed for [dec]/[dec]
Explanation

Memory allocation for SPA/EPA interfaces failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_LICENSE_POLICY_MANAGER-6-LIC_REQ_SUC : [int]/[int]/[int]: License request is successful for [chars] feature
Explanation

License release is successful, port allowed to go down
Recommended Action

Nothing the system is working properly
%IOSXE_LICENSE_POLICY_MANAGER-6-LIC_REL_SUC : [int]/[int]/[int]: License release is successful for [chars] feature
Explanation

License release is successful, port allowed to go down
Recommended Action

Nothing the system is working properly
%IOSXE_LICENSE_POLICY_MANAGER-4-INSUF_LIC : [int]/[int]/[int]: Insufficient [chars] license, skipping license request assuming
customer has honor license
Explanation

Permanent/Evaluation licenses have exhausted, skipping license request asuming customer has purchased license
Recommended Action

Nothing the system is working properly
%IOSXE_LICENSE_POLICY_MANAGER-4-DISABLE_MACSEC : [chars]: Disabling MACsec configuration due to insufficient license
Explanation

Disabling MACsec configuration from port due to insufficient MACsec license
Recommended Action

Purchase/Install MACsec license

IOSXE_MEMPOOL_MIB

%IOSXE_MEMPOOL_MIB-3-BUFFPOOL_REG_ERROR : Bufferpool register data exceeds allocated memory; Retrieved only [dec] entries.
Explanation

Memory allocated is not enough
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_MGMTVRF through IOSXE_RP_IF_FLOW_IDS

  • IOSXE_MGMTVRF

  • IOSXE_MLP

  • IOSXE_OIR

  • IOSXE_PEM

  • IOSXE_PLATFORM

  • IOSXE_QFP

  • IOSXE_RP_ALARM

  • IOSXE_RP_CFG_NOT

  • IOSXE_RP_DPIDB

  • IOSXE_RP_IF_FLOW_IDS

IOSXE_MGMTVRF

%IOSXE_MGMTVRF-3-PROCESS_CREATE_FAIL : Management VRF process creation failed, [chars]
Explanation

Can not create IOS process for mgmt port init
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_MGMTVRF-3-VRF_CREATE_FAIL : Management VRF creation failed [chars]
Explanation

Can not create mgmt vrf during system init
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_MGMTVRF-3-AFI_ATTACH_FAIL : Management VRF AFI [chars] attach failed
Explanation

Can not create afi subblock for mgmt vrf
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_MGMTVRF-3-INTF_ATTACH_FAIL : Management VRF attach to mgmt [chars] failed
Explanation

Can not associate mgmt port to mgmt vrf
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_MGMTVRF-3-SET_TABLEID_FAIL : Installing [chars] Management interface tableid [hex] failed
Explanation

Fail to set mgmt port tableid into Linux kernel
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_MGMTVRF-6-CREATE_SUCCESS_INFO : Management vrf [chars] created with ID [dec], ipv4 table-id [hex], ipv6 table-id [hex]
Explanation

mgmt vrf and ipv4, ipv6 tables created for mgmt port
Recommended Action

IOSXE_MLP

%IOSXE_MLP-3-ENQUEFAIL : Unable to send [chars] [chars] message to Forwarding Manager Process
Explanation

An unexpected condition has occurred which resulted in a configuration not being sent to the Forwarding Manager Processs.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_MLP-4-UPDSTATSERR : Update MLP statistics error
Explanation

An unexpected condition has occurred when updating mlp statistics
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_MLP-2-DB_ENTRY_ALLOC_FAIL : MLP link db entry allocation for link [chars] failed
Explanation

MLP link database error. Memory chunk allocation for MLP link database entry has failed.
Recommended Action

Check for accurate memory management. Perform memory leak checks and look for memory corruption causes. Execute ‘show proc
memory’ command.
%IOSXE_MLP-2-DB_INSERT_FAIL : MLP link db entry add for interface [chars] failed
Explanation

MLP link database error. Insertion of a new entry into MLP link database has failed.
Recommended Action

Check for accurate memory management. Perform memory leak checks, look for memory corruption causes, verify correct database
management. Execute ‘show proc memory’ command.
%IOSXE_MLP-2-DB_DELETE_FAIL : MLP link db entry delete for link [chars] failed
Explanation

MLP link database error. Removal of entry from MLP link database has failed.
Recommended Action

Check for accurate memory management. Perform memory leak checks, look for mamory corruption causes and check for correct
database management. Execute ‘show proc memory’ command.
%IOSXE_MLP-2-DB_ENTRY_FREE_FAIL : MLP link entry free failed
Explanation

MLP link database error. Memory chunk free of MLP link database entry has failed.
Recommended Action

Check for accurate memory management. Perform memory leak checks and look for memory corruption causes. Execute ‘show proc
memory’ command.
%IOSXE_MLP-2-DB_ALLOC_FAIL : MLP link db allocation failed
Explanation

MLP link database error. Memory chunk creation for MLP link database has failed.
Recommended Action

Check for accurate memory management. Perform memory leak checks and look for memory corruption causes. Execute ‘show proc
memory’ command.
%IOSXE_MLP-2-DB_DESTROY_FAIL : MLP link database destroy failed
Explanation

MLP link database error. Memory chunk destroy has failed for MLP link database.
Recommended Action

Check for accurate memory management. Perform memory leak checks and look for memory corruption causes. Execute show proc
memory command.

IOSXE_OIR

%IOSXE_OIR-6-INSCARD : Card ([chars]) inserted in [chars]slot [chars]
Explanation

The OIR facility detected the insertion of a card in the slot number specified in the message.
Recommended Action

No action is required.
%IOSXE_OIR-6-REMCARD : Card ([chars]) removed from [chars]slot [chars]
Explanation

The OIR facility detected the removal of a card from the slot number specified in the message.
Recommended Action

No action is required.
%IOSXE_OIR-6-ONLINECARD : Card ([chars]) online in [chars]slot [chars]
Explanation

The OIR facility detected the state change to online for the card in the slot number specified in the message.
Recommended Action

No action is required.
%IOSXE_OIR-6-OFFLINECARD : Card ([chars]) offline in [chars]slot [chars]
Explanation

The OIR facility detected the state change to offline for the card in the slot number specified in the message.
Recommended Action

No action is required.
%IOSXE_OIR-3-CARDERR : Could not read state property for [chars] slot [dec]
Explanation

The OIR facility detected a failure for exceeding the number of retries to find state chasfs property.
Recommended Action

No action is required.
%IOSXE_OIR-6-SOFT_STARTSPA : SPA([chars]) restarted in [chars]
Explanation

The SPA in the specified subslot is restarted by the command hw-module subslot
slot#/subslot#
start

Recommended Action

No action is required.
%IOSXE_OIR-3-SPA_INTF_ID_ALLOC_FAILED : Failed to allocate interface identifiers for SPA([chars]) in slot/bay: [int]/[int]
Explanation

Failed to get CC buffer and flow control identifiers for the SPA in the specified subslot Traffic cannot flow through the
SPA under this failure condition. This can happen if the system runs out of available identifiers.
Recommended Action

Try to reduce the number of interfaces configured in the system either by physically removing the SPAs or by changing the
system configuration
%IOSXE_OIR-6-SOFT_STOPSPA : SPA([chars]) stopped in [chars], interfaces disabled
Explanation

The SPA in the specified subslot is stopped by the command hw-module subslot
slot#/subslot#
stop The interfaces on that processor will be administratively shut down and marked as removed. The routing table will be flushed
of any routes through the removed interfaces.
Recommended Action

No action is required.
%IOSXE_OIR-6-SOFT_RELOADSPA : SPA([chars]) reloaded on [chars]
Explanation

The SPA in the specified subslot is reloaded by the command hw-module subslot
slot#/subslot#
reload

Recommended Action

No action is required.
%IOSXE_OIR-6-SYNCSPA : SPA ([chars]) reloading to come up in [chars] mode
Explanation

The SPA in the specified subslot is reloaded by the command hw-module subslot
slot#/subslot#
reload

Recommended Action

No action is required.
%IOSXE_OIR-6-INSSPA : SPA inserted in [chars]/[int]
Explanation

The OIR facility detected the insertion of a SPA in the subslot number specified in the message.
Recommended Action

No action is required.
%IOSXE_OIR-6-REMSPA : SPA removed from [chars]/[int], interfaces disabled
Explanation

The OIR facility detected the removal of a SPA from the subslot number specified in the message. The interfaces on that processor
will be administratively shut down and marked as removed. The routing table will be flushed of any routes through the removed
interfaces.
Recommended Action

No action is required.
%IOSXE_OIR-6-INSSSFP : Smart SFP inserted in port [chars]
Explanation

The OIR facility detected the insertion of TSoP/VCoP SSFP in the port number specified in the message.
Recommended Action

No action is required.
%IOSXE_OIR-6-REMSSFP : Smart SFP removed from port [chars]
Explanation

The OIR facility detected the removal of TSoP/VCoP SSFP in the port number specified in the message.
Recommended Action

No action is required.
%IOSXE_OIR-6-SPARELOAD : SPA reloaded on subslot [int]/[int]
Explanation

The SPA in the specified subslot is reloaded.
Recommended Action

No action is required.
%IOSXE_OIR-6-CARDRECONCILE : SPA type changed on subslot [int]/[int] from [int] to [int]
Explanation

The SPA in the specified subslot has been initialized, and it has been detected that it is of a different type to the SPA
that was previously in this subslot.
Recommended Action

No action is required.
%IOSXE_OIR-3-OIRTWICE : Subslot [int]/[int] OIR insertion/removal not paired up: [chars]
Explanation

An internal OIR-related error occured for the specified SPA.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_OIR-3-QUIESCE_FAIL : Quiesce failed for subslot [int]/[int] (error = [dec])
Explanation

The RP failed to contact the SPA during failover. The SPA will be reset.
Recommended Action

No action is required.
%IOSXE_OIR-3-UNQUIESCE_FAIL : Unquiesce failed for subslot [int]/[int] (error = [dec])
Explanation

The RP failed to unquiesce the SPA in the specified subslot. The SPA will be reset.
Recommended Action

No action is required.
%IOSXE_OIR-3-POWER_CYCLE_IMMINENT : The SPA in subslot [int]/[int] will be power cycled in [dec] seconds.
Explanation

The SPA in the specified subslot will be power cycled in the amount of time specified in the error message.
Recommended Action

No action is required.
%IOSXE_OIR-3-PROCMSG : Process msg send failed for process[dec]
Explanation

Process message send failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_OIR-3-MODULE : Missing [chars] for [chars]
Explanation

A hardware or software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_OIR-3-SPA_MDR_FAIL : Minimal Disruptive Restart process failed for SPA in subslot [int]/[int], reason [chars].
Explanation

The SPA in the subslot failed Minimal Disruptive Restart. Minimal Disruptive Restart process is aborted and an attempt will
be made to recover the SPA by resetting the SPA hardware.
Recommended Action

No action is required.

IOSXE_PEM

%IOSXE_PEM-6-INSPEM_FM : PEM/FM [chars] inserted
Explanation

The platform detected the insertion of a power/fan module in the slot number specified in the message.
Recommended Action

No action is required.
%IOSXE_PEM-6-REMPEM_FM : PEM/FM [chars] removed
Explanation

The platform detected the removal of a power/fan module in the slot number specified in the message.
Recommended Action

No action is required.
%IOSXE_PEM-6-PEMOK : The PEM in [chars] is functioning properly
Explanation

The PEM hardware may have been either switched off, or reporting a failure condition. This message indicates that the PEM
is no longer either switched off, or reporting a failure
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_PEM-3-PEMFAIL : The PEM in [chars] is switched off or encountering a failure condition.
Explanation

The PEM hardware has been either switched off, or is reporting a failure condition.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_PEM-6-FANOK : The fan in [chars]/[dec] is functioning properly
Explanation

The fan was reporting a failure condition. This message indicates that the fan is no longer reporting a failure
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_PEM-3-FANFAIL : The fan in [chars]/[dec] is encountering a failure condition
Explanation

The fan’s hardware is reporting that the fan is failing. This is most likely because the hardware detects the fan as spinning
below the minimum speed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_PEM-3-PEMCHASFSERR : The PEM in [chars] has encountered a system software error.
Explanation

The PEM’s underlying software for storing PEM state is not working properly.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_PEM-3-TEMPERATURE_RAISE : Sensor [chars] has reached maximum temeprature value, Leads to shutdown the system
Explanation

The Temperature sensor reaching maximum threshold value working properly.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_PEM-3-FAN_FAIL_SHUTDOWN : More thatn one [chars] has failed, Leads to shutdown the system
Explanation

The Temperature sensor reaching maximum threshold value working properly.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_PEM-3-SSFP_TEMPERATURE_RAISE : [chars] transceiver temeprature reached threshold value, Leads to shutdown the system
Explanation

The Temperature sensor reaching maximum threshold value working properly.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_PEM-3-PEMREDLOWSTANDBY : Cannot activate [chars] configuration. Total power budget of standby power supplies is [dec]W.
Standby power must be greater than or equal to the largest power supply capacity ([dec]W).
Explanation

Operating in unprotected mode Should insert at least one ps in standby slots with a capacity greater than or equal to the
largest capacity power supply in the system. The configuration will be applied automatically once requirements are met.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_PEM-3-PEMREDNOPWR : Cannot enable power redundancy mode [chars] because config would create mode with insufficient
[chars] power
Explanation

Configuration set by user is not valid as power supplies in the active slots do not contain enough power to meet the power
requirements
Recommended Action

Insert additional power supplies and configure them to be active or configure current standby power supplies to active such
that power requirements are met

IOSXE_PLATFORM

%IOSXE_PLATFORM-3-WDC_INVALID_LENGTH : WDC length can not be determined: [dec]
Explanation

WDC length was not retrieved properly
Recommended Action

Check if WDC is programmed on this device
%IOSXE_PLATFORM-3-WDC_NOT_FOUND : WDC returned length: [dec]
Explanation

WDC length was set to 0, which specifies probably WDC does not exist
Recommended Action

Check if WDC is programmed on this device
%IOSXE_PLATFORM-3-WDC_TLV_NOT_FOUND : WDC TLV could not be read from the Quack device
Explanation

WDC TLV couldn’t be read from the Quack device
Recommended Action

Check if WDC is programmed on this device

IOSXE_QFP

%IOSXE_QFP-2-LOAD_EXCEED : Slot: [int], QFP:[int], Load [int]%[hex]ceeds the setting threshold.
Explanation

QFP Load exceeds setting threshold.
Recommended Action

Monitor the traffic load.
%IOSXE_QFP-2-LOAD_RECOVER : Slot: [int], QFP:[int], Load [int]%% recovered.
Explanation

QFP Load recovered.
Recommended Action

No action required (normal operation).

IOSXE_RP_ALARM

%IOSXE_RP_ALARM-6-INFO : [chars] [chars] [chars]: [chars] [chars]
Explanation

Recommended Action

%IOSXE_RP_ALARM-6-INFO : [chars] [chars] [chars] [chars] [chars]
Explanation

Alarm assertion or deassertion information.
Recommended Action

No action is required.
%IOSXE_RP_ALARM-2-PEM : [chars] [chars] [chars]: [chars] [chars]
Explanation

Recommended Action

%IOSXE_RP_ALARM-2-PEM : [chars] [chars] [chars] [chars] [chars]
Explanation

Power Entity Module missing information
Recommended Action

No action is required.
%IOSXE_RP_ALARM-2-ESP : [chars] [chars] [chars]: [chars] [chars]
Explanation

Recommended Action

%IOSXE_RP_ALARM-2-ESP : [chars] [chars] [chars] [chars] [chars]
Explanation

No ESP running alarm information
Recommended Action

No action is required.

IOSXE_RP_CFG_NOT

%IOSXE_RP_CFG_NOT-3-MSGNOCAND : Can not construct a candidate entry for configuration export
Explanation

This error usually indicates either an out of memory condition or a TDL error. If ample memory is available, then the the
TDL error may indicate a version conflict with respect to configuration.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-3-MSGNOPWARR : Can not construct an array for configuration export
Explanation

This error usually indicates either an out of memory condition or a TDL error. If ample memory is available, then the the
TDL error may indicate a version conflict with respect to configuration.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-3-MSGNOUPDATEMSG : Can not construct an update message for configuration export
Explanation

This error usually indicates either an out of memory condition or a TDL error. If ample memory is available, then the the
TDL error may indicate a version conflict with respect to configuration.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-3-MSGNOREPLMSG : Can not construct a replace message for configuration export
Explanation

This error usually indicates either an out of memory condition or a TDL error. If ample memory is available, then the the
TDL error may indicate a version conflict with respect to configuration.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-2-MSGNOEXP : Can not construct a ‘[chars]’ message for configuration export: [chars]
Explanation

This error usually indicates either an out of memory condition or a TDL error. If ample memory is available, then the the
TDL error may indicate a version conflict with respect to configuration.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-2-MSGTDLINITERROR : Configuration Notification messaging module initialization failed: Unable to initialize
messaging: [chars]
Explanation

The Configuration Notification subsystem has failed to initialize the infrastructure for messaging with the Pluggable Services
Daemon. Notification of configuration to critical modules cannot proceed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-2-MSGTDLERROR : Error processing TDL message. [dec]
Explanation

An unexpected condition in which IOS has received a TDL message which it can not process.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-2-MSGIPCINITERROR : Error initializing IPC queue
Explanation

An unexpected condition in which IOS could not initialize a message queue to the PSD.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-3-MSGIPCTXERROR : IPC transmit error. [dec]
Explanation

An unexpected condition in which IOS encountered an error trying to send a message to another process. %d
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-3-MSGOBJNULL : An unexpected condition in which IOS has received a null pointer that it expects to be non-null.
Explanation

An unexpected condition has occurred while IOS is trying to process a username command.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-3-MSGENCRYPTINVALID : The mcprp_cfg_notify subsystem has seen an encryption type it does not recognize.
[dec]
Explanation

An unexpected condition has occurred while IOS is trying to process a username command.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-3-NVWRITE_EXPORT : Failed to export [chars] notification: [dec]
Explanation

When a ‘write memory’ or ‘write erase’ operation occurs, the Configuration Notification subsystem exports this event into
the chassis file system. This message indicates that the export failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-3-MCP_DBPERSIST_STAT : Failed to read [chars] property: [dec]
Explanation

When a ‘reload’ operation occurs, this chasfs property is read to determine the status of the DB persist/restore/delete operation.
This message indicates that the read failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-3-MCP_DBPERSIST_ERROR : System configuration update could not complete
Explanation

When a ‘reload’ operation occurs, this chasfs property is read to determine the status of the DB persist/restore/delete operation.
This message indicates that the operation failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-3-MCP_FRU_LOCATION : Failed to get local FRU location: [dec]
Explanation

Unable to get local FRU location
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-3-MCP_FRU_INVALID : Unknow FRU location: [chars]
Explanation

Unknown FRU location
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-3-BOOT_VAR_NOT_SET : Boot variable either does not exist or buffer is too small. Keeping it blank.
Explanation

Boot variable either does not exist or buffer is too small. Not able to set boot variable. Ignoring it.Aborting reload.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-3-BOOT_IMAGE_NOT_FOUND : Primary image is not found, the system is going to reload as per user request.
Explanation

Primary image which is set in boot statement either does not exist or not found. Primary image is not found, it should prompt
the user to see if they wish to proceed. Aborting reload.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_CFG_NOT-6-IOX_SERVICE_NOTSUPPORTED : IOx service not supported.
Explanation

IOx service is not supported in this platform currently. This may be either due to the feature unavailability or due the current
inadequate license level of the system.
Recommended Action

IOSXE_RP_DPIDB

%IOSXE_RP_DPIDB-3-IDXBADRANGE : Datapath IDB index [dec] is not in a valid range
Explanation

An unexpected condition has occurred as the index of a datapath IDB is not valid.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-IDXALLOCFAILED : Datapath IDB index allocation failed: [chars]
Explanation

An unexpected condition has occurred as all the available of datapath IDB indices are used.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-IDXINSERTFAILED : Insertion of datapath IDB index [dec] into database failed
Explanation

An unexpected condition has occurred that insertion of datapath IDB indices failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-IDXLOOKUPFAILED : Lookup of datapath IDB index from the database failed ([chars])
Explanation

An unexpected condition has occurred that lookup of datapath IDB indices failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-IDXDELETIONFAILED : Deletion of datapath IDB index from the database failed ([chars] — [hex]) rc [dec]
Explanation

An unexpected condition has occurred that deletion of datapath IDB indices failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-NOHWSUBBLOCK : HWIDB [chars] does not have a hardware subblock
Explanation

An unexpected condition has occurred that no hardware subblock was previously allocated for a HWIDB.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-NOSWSUBBLOCK : SWIDB [chars] does not have a software subblock
Explanation

An unexpected condition has occurred that no software subblock was previously allocated for a SWIDB.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-IDBBADTYPE : Datapath IDB type [dec] is not valid
Explanation

An unexpected condition has occurred as the type of a datapath IDB is not valid.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-IDBEXIST : Datapath IDB already exists in this mapping entry: [chars]-[dec]
Explanation

An unexpected condition has occurred that an attempt is made to save datapath IDB in a mapping entry filled by another.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-IDBNONEXIST : Datapath IDB does not exist in this mapping entry: [chars]-[dec]
Explanation

Datapath IDB lookup points to empty mapping entry.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-RF : Datapath IDB RF operation failed — [chars]
Explanation

Failure in some datapath ID RF activity.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-CF : Datapath IDB CF operation failed — [chars]
Explanation

Failure in some datapath ID CF activity.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-RPC : Datapath IDB RPC operation failed — [chars]
Explanation

Failure in some datapath ID RPC activity.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-REGISTRATION : ISSU [chars] failed for [chars]; [chars]
Explanation

An ISSU registration for the set of initial capabilities and sessions failed due to the reason specified. This will have the
effect of the DPIDX ISSU support being unavailable between peers.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-ISSU : [chars] [chars] failed; [chars]
Explanation

An operation pertaining to the ISSU support for DPIDX failed to complete using either the CF or IPC transport context with
the reason specified
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-TRANSFORM : [chars] of [chars] via [chars] failed for dpidx [int]
Explanation

An attempt to either encode or decode a versioned synchronization message has failed due to an internal error encountered
by the ISSU component.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-RECEIVE : Message via [chars] is [chars]
Explanation

An attempt to receive and process a versioned negotiation or synchronization message has failed due to an internal error being
detected by the information received from the IPC or CF components.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-TRANSMIT : Unable to send via [chars] [chars] [chars] [chars]; [chars]
Explanation

An attempt to send a versioned negotiation or synchronization message has failed due to an internal error encountered by the
IPC or CF components.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-NEGOTIATION : Failed to start ISSU [chars] session negotiation; [chars]
Explanation

The ISSU negotiation with the peer failed to start for either the CF or IPC transport with the reason specified.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-6-READY : [chars] peer not ready, discarding [chars]
Explanation

The synchronization attempt for the message has determined that the transport has lost communication with its peer. This is
a normal situation which indicates that the standby route-processor is currently out of service implying a simplex redundancy
mode.
Recommended Action

%IOSXE_RP_DPIDB-6-RELOAD : [chars], reloading [chars]
Explanation

A synchronization attempt between the active and standby RP peers has failed with the reason indicated. The standby peer is
reloaded in an attempt to resynchronize when operating in a stateful redundant mode.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-DECODE : Decode via [chars] of [chars] failed
Explanation

A message of the transport and type described failed in its attempt to be decoded on the standby. The resultant action taken
by the standby route processor is an attempt to resynchronize.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-PROGRESSION : Unable to inform RF of bulk sync completion; [chars]
Explanation

The active route processor has sent a notification to the standby to inform of the completion of the bulk synchronization
of the DPIDX configuration. The standby has failed to respond to the active informing that it received the notification noting
the reason for the failure. The resultant action taken by the standby route processor is an attempt to resynchronize.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-BULK_SYNC : Failed to send [chars] information to peer
Explanation

The bulk synchronization of the DPIDX configuration to the standby RP has failed to complete successfully; DPIDX has therefore
taken the action which will result in a reload of the peer in order to once more attempt to successfully synchronize the configuration
state which may have failed initially to a transient condition.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-DYN_SYNC : Failed to process [chars] dynamic state
Explanation

The incremental synchronization of the DPIDX configuration to the standby RP has failed to complete successfully. This implies
that the configuration state between the active and standby RP is inconsistent.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interfaces command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-6-TIMEOUT : Bulk sync is flow controlled by [chars]
Explanation

The bulk synchronization of the DPIDX configuration to the standby RP has encountered a flow control condition which has effected
a timeout awaiting the condition to clear. This will result in a reload of the standby RP to allow the bulk synchronization
to restart.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-IDBNOTVAI : Invalid API call for [chars]
Explanation

Failure in an internal API
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-NULLTIMER : NULL timer
Explanation

A timer is NULL
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-LIST : List [chars] failed for [chars]
Explanation

List enqueue or removal failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-FASTNOTIFY : Fast notify failed for [chars]
Explanation

A fast notify message failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-DOWNLOADFAIL : Unable to download [chars] message to [chars]
Explanation

An unexpected condition has occurred which resulted in a configuration not being sent to the reported process.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-FRRLDFLOWIDDELETIONFAILED : Deletion of fast-reroute flow ID with manager failed
Explanation

An unexpected condition has occurred that deletion of fast-reroute flow ID.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show interface command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-EFPSTATSFAILED : EFP stats message data get error: ([dec]) for EFP [int] on [chars]
Explanation

An unexpected error occurred extracting fields from an EFP stats message.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_DPIDB-3-MTU_ALLOC_FAIL : No hardware resources for [int] byte MTU on [chars]
Explanation

We reached to the threshold of maximum supported unique MTU on this platform.
Recommended Action

No action is required.
%IOSXE_RP_DPIDB-3-IP_MTU_ALLOC_FAIL : No hardware resources for [int] byte IP MTU on [chars]
Explanation

We reached to the threshold of maximum supported unique IP MTU on this platform.
Recommended Action

No action is required.

IOSXE_RP_IF_FLOW_IDS

%IOSXE_RP_IF_FLOW_IDS-3-NO_BUFF_FOR_SYNC : The Checkpoint Faclity reported the error [chars] during a request for a buffer
length of [dec]. This [chars] CF client has failed to synchronize a transaction to the Standby RP.
Explanation

This error indicates that the buffer management within the Checkpoint Facility has either run out of buffers, or has some
other problem. If this occurs during Bulk Sync then Bulk Sync will terminate without completing. Otherwise the incremental
Sync will fail.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-BUFF_OFFSET_NULL : Unable to utilize the memory buffer provided by the Checkpoint Facility. This
[chars] CF client has failed to Bulk Sync.
Explanation

This error indicates the Checkpoint Facility is having problems recognizing its own buffer layout. If this occurs during Bulk
Sync then Bulk Sync will terminate without completing. Otherwise the incremental Sync will fail.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-CF_SEND_BULK_NONBLOCKED : The Checkpoint Facility reported the error [chars] while attempting to
send a message. Bulk Sync of this [chars] CF client is terminating.
Explanation

This error indicates the Checkpoint Facility has internal problems related to IPC, and cannot perform a non-blocked send operation.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-DEFERRED_DURING_BULK_SYNC : Encountered error [chars] while trying to place an [chars] transaction
on the Deferred list during Bulk Sync for the [chars] CF client.
Explanation

Unable to cache a deferred transaction while Bulk Sync is underway. This can adversely impact SSO state on the Standby RP.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-CF_SEND_INCR_NONBLOCKED : The Checkpoint Facility reported the error [chars] while attempting to
send a non-blocked message. The Incremental Sync transaction for this [chars] CF client cannot be sent to the Standby RP.
Explanation

This error indicates the Checkpoint Facility has internal problems related to IPC.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-6-CFPEER_CANNOT_RECV : The Checkpoint Peer is not ready to receive messages. The Incremental Sync transaction
for this [chars] CF client will not occur.
Explanation

This error indicates the Checkpoint Facility has signalled the peer has gone away.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-SEND_FAIL_RELOAD : Checkpoint Facility Failed to send a [chars] transaction for this [chars] CF client.
Reloading the Standby RP.
Explanation

This indicates the underlying Checkpoint Facility could not deliver a message sent from the active RP to the standby RP. The
process will automatically reload the standby RP.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-4-DEF_LIST_REMOVE : Failed to remove one entry from the Deferred Sync list, for the [chars] CF client.
Explanation

An unexpected condition occured during list maintenance.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-CF_CANNOT_REGISTER : The call to add this [chars] CF client to the Checkpoint Facility failed with
the error [chars]. This client is unable to proceed and will not be registered.
Explanation

For some reason the Checkpoint Facility will not register this client. As a result the Standby will never receive synchronized
state from this CF client on the Active RP, The system is not capable of SSO and HA switchover.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-RF_PEER_EVENT_BUFFER : This [chars] RF client is unable to acquire an event buffer to send an RF
peer message, the error [chars] was returned.
Explanation

This indicates the RF facility is unable to provide a message buffer needed to communicate with the RF peer. As a consequence
the RF progression may be compromised.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-RF_SEND_PEER : This [chars] RF client encountered error [chars], when attempting to send a peer message.
Explanation

This indicates the RF facility could not send a message to the RF peer. As a consequence the RF progression may be compromised.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-RF_PROCESS_FAILED : This [chars] RF client Failed to create the Bulk Sync Process.
Explanation

The background process which performs the RF Bulk Sync failed to be created. As a consequence the Standby will never obtain
the relevent SSO state to enable HA switchover.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-RF_POOL_REGEN_PROCESS_FAILED : The [chars] RF client Failed to create the Id Pool Regeneration process.
Explanation

The background process which performs Flow Control Id Pool regeneration failed to start. As a consequence the Standby will
never obtain the relevent SSO state to enable HA switchover.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-RF_POOL_REGEN_ERROR : Id Pool Regeneration encountered error code [dec], cannot switchover.
Explanation

The background process which performs Flow Control Id Pool regeneration encountered an error. As a consequence the Standby
does not have valid Flow Id pools and cannot progress to Active state.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-RF_SPA_ID_REGEN_ERROR : Error code [dec] encountered trying to regenerate spa [chars] identifier
in slot/subslot ([int]/[int])
Explanation

The background process which performs Flow Control Id Pool regeneration encountered an error. As a consequence the Standby
does not have valid Id pools and cannot progress to Active state.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-RF_IF_ID_REGEN_ERROR : Error code [dec] encountered trying to regenerate interface flow-control identifer.
If id [int] resides in slot/subslot/port ([int]/[int]/[int]).
Explanation

The background process which performs Flow Control Id Pool regeneration encountered an error. As a consequence the Standby
does not have valid Id pools and cannot progress to Active state.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-RF_ADD_CLIENT_FAILED : The RF facility failed to add this [chars] client, reason given is [chars].
Explanation

This indicates the RF facility could not add the client.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-REGISTRATION : ISSU [chars] failed for [chars]; [chars]
Explanation

An ISSU registration for the set of initial capabilities and sessions failed due to the reason specified. This will have the
effect of the SPA MARMOT ID ISSU support being unavailable between peers.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-ISSU_OP : [chars] [chars] failed; [chars]
Explanation

An operation pertaining to the ISSU support for SPA MARMOT IDs failed to complete using the CF transport context with the
reason specified
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-TRANSFORM : [chars] of [chars] via CF failed
Explanation

An attempt to either encode or decode a versioned synchronization message has failed due to an internal error encountered
by the ISSU component.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-TRANSMIT : Unable to send via [chars] [chars] [chars] [chars]; [chars]
Explanation

An attempt to send a versioned negotiation or synchronization message has failed due to an internal error encountered by the
CF component.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-NEGOTIATION : Failed to start ISSU [chars] session negotiation; [chars]
Explanation

The ISSU negotiation with the peer failed to start for either the CF or IPC transport with the reason specified.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-6-READY : [chars] peer not ready, discarding [chars]
Explanation

The synchronization attempt for the message has determined that the transport has lost communication with its peer. This is
a normal situation which indicates that the standby route-processor is currently out of service implying a simplex redundancy
mode.
Recommended Action

%IOSXE_RP_IF_FLOW_IDS-3-DECODE : Decode via CF of [chars] failed
Explanation

A message sent via the CF transport failed in its attempt to be decoded on the standby. The resultant action taken by the
standby route processor is an attempt to resynchronize.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_IF_FLOW_IDS-3-RECEIVE : Client reports message CF is [chars]
Explanation

An attempt to receive and process a versioned negotiation or synchronization message has failed due to an internal error being
detected by the information received from the CF component.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_RP_MGMTE through IOSXE_TIMESTAMP_ENGINE

  • IOSXE_RP_MGMTE

  • IOSXE_RP_NV

  • IOSXE_RP_SPA

  • IOSXE_RP_VTYMGT

  • IOSXE_SERVICE_ENGINE

  • IOSXE_SIP_SPA

  • IOSXE_SPA

  • IOSXE_SYS_INFRA

  • IOSXE_THROUGHPUT

  • IOSXE_TIMESTAMP_ENGINE

IOSXE_RP_MGMTE

%IOSXE_RP_MGMTE-3-MSGCREATENULL : Cannot allocate [chars] TDL message
Explanation

An unexpected condition in which IOS cannot allocate TDL message for Management ethernet.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_MGMTE-3-MSGTDLINITERROR : Management ethernet interface messaging module initialization failed: Unable to initialize
messaging: [chars]
Explanation

The Management ethernet interface subsystem has failed to initialize the infrastructure for messaging with the Pluggable Services
Daemon. Configuration of management ethernet modules cannot proceed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_MGMTE-3-PROCESS_CREATE_FAIL : Management ethernet statistics process creation failed
Explanation

Can not create IOS process for RP management ethernet port statistics collection
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_MGMTE-3-MGMT_MAC_MODIFY_FAIL : Management ethernet interface mac address modification failed
Explanation

Can not override mac-address for management ethernet interface
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_RP_NV

%IOSXE_RP_NV-3-NV_ACCESS_FAIL : Initial read of NVRAM contents failed
Explanation

This error happens when the contents of the NVRAM cannot be read during system initialization. The failure may be due to data
corruption of the NVRAM contents. The initial configuration dialog will be entered and the configuration must be restored.
Recommended Action

LOG_STD_ACTION
%IOSXE_RP_NV-3-BACKUP_NV_ACCESS_FAIL : Initial read of backup NVRAM contents failed
Explanation

This error happens when the contents of the backup NVRAM cannot be read during system initialization. The failure may be due
to data corruption of the backup NVRAM contents. The primary nvram contents will be backed up here again.
Recommended Action

LOG_STD_ACTION

IOSXE_RP_SPA

%IOSXE_RP_SPA-3-SEND_NGIO_MSG_FAIL : NGIO Module message send failed for slot [dec] subslot [dec]
Explanation

Failed to send ngio msg to iomd.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-3-MAC_FILTER_ADD_FAIL : All the available [dec] mac filters for [chars] have been consumed. Failed to add [enet]
for interface [chars]
Explanation

The hardware cannot support any more filters.
Recommended Action

The interface configuration should be reworked to not cross the limit set by the hardware. If the error is still seen please
LOG_STD_SH_TECH_ACTION
%IOSXE_RP_SPA-3-SEND_L2_HDR_MSG_FAIL : slot [dec] subslot [dec]
Explanation

Failed to send ngio L2 header to iomd.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-3-NO_HOST_INFO : slot [dec] subSlot [dec], spaType [hex]
Explanation

Failed to get information about the host linecard.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-3-MAX_SPA : Power to IPSEC-SPA-2G in [chars] is denied because it has exceeded the number allowed([dec])
Explanation

The number of IPSEC-SPA-2G in a chassis is limited. This message is displayed when the number of IPSEC-SPA-2G in the chassis
has exceeded this limit.
Recommended Action

Use only the number of supported IPSEC-SPA-2G
%IOSXE_RP_SPA-3-SPA_NO_HOST_INFO : slot [dec] subSlot [dec], PID [chars]
Explanation

Failed to get information about the host linecard.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-3-HWIDB_FAILURE : Creation: slot [dec] subSlot [dec] port [dec] vc [dec]
Explanation

Failed to create an interface hwidb.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-3-INVALID_PORT_NUM : slot=[dec] port=[dec], hwidbType=[hex], max_port_num=[dec], LCtype=[hex]
Explanation

The port number is out of range.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-4-SPA_RESP_CMD_MISMATCH : [chars]: Expecting response to interface configuration command [int] but received
response to command [int].
Explanation

An internal synchronization error occurred while configuring the interface. The configuration may not have succeeded.
Recommended Action

Check that the running configuration for the interface is correct. If this message occurred on the standby, try reloading
the standby to ensure that its configuration is in sync. If this message is repeatable, please LOG_STD_SH_TECH_ACTION
%IOSXE_RP_SPA-6-CARDRELOAD : Module [int] reload due to SPA insert in [int]/[int].
Explanation

When inserting a SPA on this carrier card, the card is reset.
Recommended Action

No action is required.
%IOSXE_RP_SPA-6-CTRLRSWITCH : switching controller type from [chars]([dec]) to [chars]([dec]) for subslot [int]/[int].
Explanation

When IOSXE-SIP40 is inserted in the slot previously occupied by IOSXE-SIP10 or vice-versa the controller type of the card
is overwritten to reflect the current SIP.
Recommended Action

No action is required.
%IOSXE_RP_SPA-4-SPA_CMD_NO_RESP : [chars]: No response for interface configuration command [int]
Explanation

A timeout occurred while RP was waiting for a response from line card. This may happen due to line card CPU being too busy
to respond to the command.
Recommended Action

No action is required.
%IOSXE_RP_SPA-3-IPCALLOCFAIL : Failed to allocate IPC buffer [chars]
Explanation

The RP failed to allocate a buffer for communication with a SPA
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-3-DPIDX_LKUP_FAIL : Failed to retrieve datapath identifier for interface [chars]
Explanation

The SPA driver is not able to retrieve the datapath identifier for the interface specified in the message. This indicates
a software error.
Recommended Action

No action is required.
%IOSXE_RP_SPA-3-FLOWID_ALLOC_FAIL : Failed to allocate a flow control identifier for interface [chars]
Explanation

The SPA driver is not able to allocate the datapath flow control identifier for the interface specified in the message. This
indicates a software error.
Recommended Action

No action is required.
%IOSXE_RP_SPA-3-FLOWID_RELEASE_FAIL : Failed to release a flow control identifier for interface [chars] (status = [dec])
Explanation

The SPA driver is not able to release the datapath flow control identifier for the interface specified in the message. This
indicates a software error.
Recommended Action

No action is required.
%IOSXE_RP_SPA-3-VC_PROV_FAIL : Failed to provision interface [chars]
Explanation

The SPA driver is not able to provision the interface specified in the message. Verify that the SPA hardware is not provisioned
above the supported limit. Otherwise, this indicates a hardware error.
Recommended Action

No action is required.
%IOSXE_RP_SPA-3-CI_UPDATE_FAIL : Failed to update connection identifier for interface [chars]
Explanation

The SPA driver is not able to update the datapath connection identifier for the interface specified in the message. This indicates
a software error.
Recommended Action

No action is required.
%IOSXE_RP_SPA-3-NULL_DATA_STRUCTURE : common_str_empty_str
Explanation

A SPA driver is not able to retrieve the data structure mentioned in the message. This indicates a software error.
Recommended Action

No action is required.
%IOSXE_RP_SPA-3-HWIDB_INIT_FAIL : Failed to initialize data structure for SPA port [dec]/[dec]/[dec]
Explanation

A SPA driver was not able to properly initialize a data structure mentioned in the message. This indicates a software error.
Recommended Action

No action is required.
%IOSXE_RP_SPA-3-ERROR : common_str_empty_str
Explanation

This message can take many forms. It provides information about a software error.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-4-LCLOG_TOOLONG : Message too long from slot [int]/[int]: [int] bytes
Explanation

The SPA module passed down a logger message that is too long for the RP to handle.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-4-LCLOG_PARSE_ERR : Error parsing logger message: [chars] from subslot [int]/[int]
Explanation

The SPA module passed down a logger message that could not be parsed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-3-BAD_IFCOMTYPE : Bad ifcom message type=[int]
Explanation

A SPA module passed down a message that the RP software was not prepared to handle.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-4-IPCFAILED : IPC failed to send RPC message to SPA module
Explanation

The RP failed to send an RPC message via IPC to a SPA module.
Recommended Action

No action is required.
%IOSXE_RP_SPA-3-FOREVER : cmd [int] to [chars] (slot [int]/[int]) took [int]secs, done [hex]
Explanation

A CCB command from the RP to a SPA module took longer than expected.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-4-SEMAHOG : Process [dec] ([chars]) hogging [chars]! calling proc [dec] ([chars])
Explanation

The RP waited too long for a reply to a command sent to a SPA module.
Recommended Action

No action is required.
%IOSXE_RP_SPA-3-IPCPORTFAIL : Failed to open IPC port ‘[chars]’ with error [chars]
Explanation

The RP failed to open a port for communication with a SPA module.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-4-CCB_PLAYBACK_ERROR : CCB playback failed for slot [dec].
Explanation

The High Availability component for SPA modules failed to synchronize some new state information for the specified slot.
Recommended Action

Reload the standby supervisor module to force a fresh bulk synchronization. If this error recurs, LOG_STD_ACTION
%IOSXE_RP_SPA-4-CCB_RECORD_ERROR : CCB record failed for slot [dec].
Explanation

The High Availability component for SPA modules failed to record some new state information for the specified slot.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-3-IPCSENDFAIL : Failed to send IPC message [chars]
Explanation

The RP failed to send a message to a SPA module.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-3-IFCFG_NO_UNIQUE_KEY : No unique-key generator registered for interface configuration command [int].
Explanation

The High Availability component for SPA modules is unable to properly synchronize state information for the current configuration.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-3-IFCFG_FOREVER : to [chars] (slot [int]/[int]) took [int]secs, ret_val [int]
Explanation

A interface config command from the RP to a SPA module took longer than expected.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-4-IFCFG_CMD_TIMEOUT : Interface configuration command ([hex]) to slot [int]/[int] timed out
Explanation

The RP sent an configuration command to the slot specified in the error message and received no confirmation for the command.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-3-IFCFG_CMD_NOT_OWNER : Process ‘[chars]’ waiting for interface configuration command ([hex]) to slot [int]/[int]
without acquiring lock owned by process ‘[chars]’
Explanation

A process on the RP sent an configuration command to the slot specified in the error message and a different process waited
for the result. This could cause incorrect line card configuration states.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-4-IFCFG_DFLT_LIST_ERROR : For Interface Configuration command [int], default retval list search resulted [hex]
for slot [int]/[int]
Explanation

The High Availability component for SPA modules failed to synchronize some new state information for the specified slot.
Recommended Action

LOG_STD_SH_CMD_ACTION(show platform redundancy if-config default-retvals)
%IOSXE_RP_SPA-4-IFCFG_PLAYBACK_ERROR : Interface Configuration command [int] playback failed for slot [int]/[int].
Explanation

The High Availability component for SPA modules failed to synchronize some new state information for the specified slot.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-4-IFCFG_RECORD_ERROR : Interface Configuration command [int] record failed for slot [int]/[int].
Explanation

The High Availability component for SPA modules failed to record some new state information for the specified slot.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-4-INCR_CFG_SYNC_FAIL : [chars] incremental running-config sync for [[dec]/[dec]] failed — [chars]([dec]) ,
Reload Standby
Explanation

The specified IOSXE incremental running-config sync failed
Recommended Action

Power cycle the redundant supervisor
%IOSXE_RP_SPA-3-IPCPORT : Failed to [chars] IPC port ‘[chars]’, error [chars]
Explanation

The Linecard failed to create a port for communication with the Route Processor (IOSXE-RP).
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IOSXE_RP_SPA-3-PROGRESSION : Unable to inform RF of bulk sync completion; [chars]
Explanation

The standby has failed to notify the active that its bulks synchronization of the SPA TSM has completed. The resultant action
taken by the standby route processor is an attempt to resynchronize.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-3-VC_FLOWID_ALLOC_FAIL : Failed to allocate a flow control identifier for VC [dec] under interface [chars]
Explanation

The SPA driver is not able to allocate the datapath flow control identifier for the VC/interface specified in the message.
This indicates a software error.
Recommended Action

No action is required.
%IOSXE_RP_SPA-3-VC_INGID_ALLOC_FAIL : Failed to allocate a ingress identifier for VC [dec] interface [chars]
Explanation

The SPA driver is not able to allocate the datapath ingress identifier for the VC/interface specified in the message. This
indicates a software error.
Recommended Action

No action is required.
%IOSXE_RP_SPA-4-SPA_RESP_CMD_ERR : [chars]: Received response to interface configuration command [chars] with wrong return
value [int].
Explanation

An internal error occurred while configuring the interface. The configuration may not have succeeded.
Recommended Action

Check that the running configuration for the interface is correct. If this message is repeatable, please LOG_STD_SH_TECH_ACTION
%IOSXE_RP_SPA-3-FRR_CFG_REC_FAIL : Failed to record fast reroute conifguration on [chars]: [chars]
Explanation

This message is displayed when a fast reroute configuration is not properly recorded.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-3-MISSING_SPA_PKG_ERR : sipspa[chars] package is not installed for slot = [dec] and subslot = [dec], SPA bootup
failed.
Explanation

This message is displayed when attempting to bootup a SPA without installing a subpackage required for the same.
Recommended Action

Download the sub-package required for the affected SPA from the Cisco CCO software download site and install the same. This
SPA can be booted in sub-package mode only. Please refer to the Cisco ASR platform documentation for obtaining and installing
sub-packages.
%IOSXE_RP_SPA-3-UNSUPPORTED_SRVCS_SPA : Service SPA ([hex]) in [dec]/[dec] is not supported. SPA bootup failed.
Explanation

This message is displayed when attempting to bootup any service SPA in router running non K9 image, i.e., non-crypto image.
Recommended Action

Download the K9 IOS XE sub-packages and the required sub-package for the given service SPA from the Cisco CCO software download
site and install the same. This SPA can be booted in sub-package mode only. Please refer to the Cisco ASR platform documentation
for obtaining and installing sub-packages.
%IOSXE_RP_SPA-3-MISSING_SPA_PKG_WARN : sipspa[chars] package is not installed in standby for slot = [dec] and subslot = [dec].
Explanation

This message is displayed in standby console when attempting to bootup or restart or reload a WMA SPA without installing a
subpackage in the standby RP, although the SPA is or will be operational due to prior wma spa package installation in active
RP. If switchover takes place the WMA SPA will still be operational. But any subsequent soft or hard oir of the SPA will fail
due to missing sub package required to boot up the SPA. Hence it is recommended to complete the wma spa package installation
in standby also before switchover or immidiately after switchover.
Recommended Action

Download the sub-package required for the affected SPA from the Cisco CCO software download site and install the same for
the standby RP as is done on active RP. Please refer to the Cisco ASR platform documentation for obtaining and installing
sub-packages.
%IOSXE_RP_SPA-3-SPA_WRONGTYPE : Mismatched SPA type ([dec]) in slot [dec]/[dec]. Expected type [dec]. Use ‘no card [dec]/[dec]’
command to override preprovisioning and update card type.
Explanation

The SPA inserted does not match the currently provisioned SPA type.
Recommended Action

Replace wrong SPA with currently provisioned SPA type, or type ‘no card’ to allow new card type to be discovered.
%IOSXE_RP_SPA-6-MEDIA_AUTOFAILOVER : Media Fail over from ([chars]) to ([chars])
Explanation

Gige Media Failover.
Recommended Action

This is inforamtional message, Not an error message. Use ‘show interface gig’ to see the current active media type.
%IOSXE_RP_SPA-3-SONET_ALARM_PROC_ERR : [chars] Error has occurred while processing in the sonet alarm-proc
Explanation

Either free/create of the memory failed in SONET alarm proc
Recommended Action

%IOSXE_RP_SPA-3-LIC_REQ_FAILED : [int]/[int]/[int]: Interface enable not allowed — license request failed , err=[hex]
Explanation

A 10 Gig License is required to enable this port. License request has been denied by license manager
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-3-LIC_REL_FAILED : [int]/[int]/[int]: Failed to release license feature [chars], handle=[hex], err=[hex]
Explanation

License release has been denied by license manager
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_SPA-3-LIC_REG_FAILED : [int]/[int]/[int]: Failed to register license feature [chars], err=[hex]
Explanation

License registration has been denied by license manager
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_RP_VTYMGT

%IOSXE_RP_VTYMGT-3-MSGDISPATCHNULL : Received NULL TDL message
Explanation

An unexpected condition in which IOS has received a NULL TDL message for Vty Management.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_VTYMGT-3-MSGDISPATCH : Unable to dispatch received TDL messages for Vty Management
Explanation

An unexpected condition has occurred while IOS is trying to dispatch to the TDL message handler functions for received TDL
messages for Vty Management.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_VTYMGT-3-MSGMISSINGFIELD : Missing field ‘[chars]’ in TDL Vty Management message ‘[chars]’ received
Explanation

A message missing a required field was received for Vty Management
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_VTYMGT-3-MSGINVALIDFIELDINT : Invalid field ‘[chars]’ in TDL message ‘[chars]’ received: value ‘[int]’ for Vty
Management
Explanation

A message with an invalid field value was received for Vty Management
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_VTYMGT-3-MSGINVALIDFIELDSTR : Invalid field ‘[chars]’ value ‘[chars]’ in TDL message ‘[chars]’ received for Vty
Management
Explanation

A message with an invalid field value was received for Vty Management
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_VTYMGT-3-MSGERROR : Error ‘[dec]’ handling a received TDL message ‘[chars]’ for Vty Management: [chars]
Explanation

An unexpected condition has occurred while IOS is processing a received Vty Management TDL message
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_VTYMGT-3-MSGBUILDERROR : Error ‘[dec]’ building TDL Vty Management message ‘[chars]’: [chars]
Explanation

An unexpected condition has occurred while IOS is building a TDL response message for Vty Management
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_VTYMGT-3-MSGMARSHALERROR : Error ‘[dec]’ marshaling TDL Vty Management message ‘[chars]’: [chars]
Explanation

An unexpected condition has occurred while IOS is marshaling TDL response message for Vty Management
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_VTYMGT-3-MSGENQUEUEERROR : Error queueing TDL Vty Management message ‘[chars]’
Explanation

An unexpected condition has occurred when IOS attempted to queue a TDL response message for Vty Management
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_VTYMGT-3-MSGBIPCERR : Unable to process received BIPC messages for Vty Management, error: [chars]
Explanation

An unexpected condition has occurred while IOS was trying to process a received BIPC message for Vty Management.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_VTYMGT-3-MSGBIPCBUFFER : Unable to acquire a BIPC buffer of length [dec] for sending messages.
Explanation

A message was to be sent by IOS, but no BIPC buffer was available. The message to be sent has been discarded and the associated
operation failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_VTYMGT-3-MSGEXTAPPUPDATE : Unable to update external application data for line ‘[dec]’
Explanation

An attempt to update the external application for a line failed unexpectedly. The line update failed and if the line number
specified is valid, the line was released.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_VTYMGT-3-MSGVTYSVCINIT : Unable to initialize the Vty Management service listen port
Explanation

The platform IPC services failed to register the Vty Management service’s need for a listen port. The Vty Management service
will be unable to process requests. IOS services will be unavailable to external access methods.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_VTYMGT-3-MSGVTYCOUNT : Invalid vty count [dec] detected on initialization
Explanation

Upon initialization, the Vty Management subsystem checks that the number of available vtys for the platform is valid.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_RP_VTYMGT-3-SET_ACCESS_FAIL : Installing LIIN interface access control failed
Explanation

This error happens when the Vty Management subsystem failed to set the access control function for the LIIN, possibly due
to IOS out of memory or corruption. Persistent access features into IOS will not work.
Recommended Action

LOG_STD_ACTION

IOSXE_SERVICE_ENGINE

%IOSXE_SERVICE_ENGINE-3-MSGOPENFAIL : Cannot open interface [chars] ([dec])
Explanation

During the creation of a Service-Engine interface, it is necessary to program the system parameters in the driver. The driver
cannot be opened.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SERVICE_ENGINE-3-MSGSETFAIL : Set id on interface [chars] ([dec])
Explanation

During the creation of a Service-Engine interface, it is necessary to program the system parameters in the driver. The failed
to accept the programming.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SERVICE_ENGINE-3-MSGINITFAIL : Initialization of interface [chars] failed
Explanation

The initialization of the interface mentioned in the error message has failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_SIP_SPA

%IOSXE_SIP_SPA-3-HWIDB_FAILURE : Creation: port [dec] vc [dec]
Explanation

Failed to create a hwidb.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SIP_SPA-3-DEVICE_ERROR : subSlot [dec], spatype [hex]. Device error: [chars]
Explanation

An error related to a device on the SPA is detected.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SIP_SPA-3-ISR_RC_ERROR : ISR return code out of range. rc=[dec]
Explanation

The ISR error return code is out of range.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SIP_SPA-3-SPA_INTF_ID_CC_ALLOC_FAILED : Failed to allocate interface identifiers for SPA ([chars]) in slot/bay: [int]/[int]
Explanation

Failed to get CC buffer and flow control identifiers for the SPA in the specified subslot Traffic cannot flow through the
SPA under this failure condition. This can happen if the system runs out of available identifiers.
Recommended Action

Try to reduce the number of interfaces configured in the system either by physically removing the SPAs or by changing the
system configuration
%IOSXE_SIP_SPA-4-SPABUS : Subslot [dec], [chars] SPA BUS access failed. timeout=[int] err=[int] par=[int] err_c=[hex] addr=[hex]
data =[hex]
Explanation

SPABUS has reported an error.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SIP_SPA-4-SPABUS2 : Subslot [dec] SPA BUS access failed. No SPA present error
Explanation

SPABUS has reported an error.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SIP_SPA-6-OIR : Bay [dec] [chars] changed to [chars]
Explanation

SPA OIR Sequence
Recommended Action

No action is required.
%IOSXE_SIP_SPA-4-MAX_BANDWIDTH : Total SPA bandwidth exceeds line card capacity of [int] Mbps
Explanation

The total bandwidth of SPAs exceeds the rated capacity of this line card.
Recommended Action

Refer to the line card guidelines for the maximum allowed aggregated SPA bandwidth for the line card
%IOSXE_SIP_SPA-4-MAX_BANDWIDTH_NS : Total SPA bandwidth exceeds line card capacity, full utilization of installed SPA interfaces
is not supported
Explanation

The total bandwidth of SPAs exceeds the rated capacity of this line card.
Recommended Action

Refer to the line card guidelines for the maximum allowed aggregated SPA bandwidth for the line card
%IOSXE_SIP_SPA-3-POWER : Bay [dec] 12V power is [chars]
Explanation

SPA 12V power fault indicator
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SIP_SPA-3-SPI4_INIT_FAILURE : Bay [dec] initialization failure
Explanation

Failed to create SPI4 subblock
Recommended Action

Seach for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, LOG_STD_ACTION
%IOSXE_SIP_SPA-3-MESSAGE_ERROR : Bay [dec]: [chars]
Explanation

An unexpected error has occurred.
Recommended Action

Seach for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, LOG_STD_ACTION
%IOSXE_SIP_SPA-3-SPI4_CONFIG_FAILURE : Bay [dec], spi4 configuration failure, error [dec]
Explanation

Failed to configure SPI4 interface
Recommended Action

Seach for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, LOG_STD_ACTION
%IOSXE_SIP_SPA-3-SPI4_NOTSYNC : [chars]: Can not synchronize SPI4 bus (host: src [chars]in sync, sink [chars]in sync, spa:
src [chars]in sync, sink [chars]in sync).
Explanation

SPI4 bus between modular services card and SPA is not synchronized. It indicates either a not properly seated SPA, a hardware
failure or an outdated ROMMON/FPGA image.
Recommended Action

Ensure that the SPA is properly seated in its subslot and reseat it if required.
%IOSXE_SIP_SPA-3-SPA_CTRL_INIT_FAILURE : Subslot [dec], spa controller initialisation failure, error [dec]
Explanation

Failed to initialise SPA controller
Recommended Action

Seach for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, LOG_STD_ACTION
%IOSXE_SIP_SPA-3-SPA_CTRL_EFC_CONFIG_FAILURE : Subslot, spa controller EFC configuration failure, error [dec]
Explanation

Failed to configure SPA controller EFC
Recommended Action

Seach for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, LOG_STD_ACTION
%IOSXE_SIP_SPA-3-FCI_NOT_SET : Bay [dec] — FCI type not set
Explanation

An FCI type of zero was detected
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SIP_SPA-3-EFC_CHAN_ERR : EFC error — interface [chars], vc [dec], anyphy [dec], err_code [dec] : [chars]
Explanation

Failed to configure efc channel/parameters
Recommended Action

Seach for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, LOG_STD_ACTION
%IOSXE_SIP_SPA-3-INVALID_ANYPHY : Bay [dec] — Invalid anyphy number [int] for vc [dec]
Explanation

Interface has invalid anyphy mumber
Recommended Action

Seach for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case or contact your Cisco technical support representative. Be sure to provide the the information you have gathered and a ‘show
tech-support’ to your support representative, or attach it to your case in non-zipped, plain text format (.txt).
%IOSXE_SIP_SPA-3-LINKREC_ERROR : Link record error — Bay [dec] vc [dec], error code [dec]
Explanation

Error processing link record structure
Recommended Action

Seach for resolved software issues using the Bug Toolkit at http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl. If you still require assistance, open a case with the Technical Assistance Center via the Internet at https://mycase.cloudapps.cisco.com/case or contact your Cisco technical support representative. Be sure to provide the the information you have gathered and a ‘show
tech-support’ to your support representative, or attach it to your case in non-zipped, plain text format (.txt).
%IOSXE_SIP_SPA-3-SONET_CLOCK_FAILED : SPA Sonet clock has failed (status = [hex])
Explanation

The SPA SONET clock has failed. SPAs that rely on the SPA SONET clock for proper operation, such as POS and ATM will be affected.
Recommended Action

If the SPA Sonet clock does not recover, perform an OIR. LOG_STD_RECUR_ACTION
%IOSXE_SIP_SPA-3-SONET_CLOCK_RECOVERED : SPA Sonet clock has recovered (status = [hex])
Explanation

SPA Sonet clock has recovered
Recommended Action

No action is required.
%IOSXE_SIP_SPA-3-INVALID_IF : Attempted to access HWIDB for port [int] on slot [dec] subSlot [dec]
Explanation

The ASR1000 attempted to access the HWIDB associated with a non-existent port.
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IOSXE_SIP_SPA-3-ASR1000IPCALLOCFAIL : Failed to allocate Common IPC buffer [chars]
Explanation

The Carrier Card failed to allocate a buffer for communication with the Route Processor.
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IOSXE_SIP_SPA-3-CMDNOINT : HWIDB Null for command [dec], port [hex]
Explanation

The Route Processor passed down a port number that is unknown on the carrier card.
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IOSXE_SIP_SPA-3-EFC_FC_MAP_FAIL : Failed to update EFC flow control identifier for interface [chars] (status = [dec])
Explanation

The SPA driver is not able to update the datapath EFC flow control identifier for the interface specified in the message.
This indicates a hardware error.
Recommended Action

No action is required.
%IOSXE_SIP_SPA-3-EFC_PROV_FAIL : Failed to provision EFC for interface [chars] (status = [dec])
Explanation

The SPA driver is not able to provision EFC for the interface specified in the message. This indicates a hardware error.
Recommended Action

No action is required.
%IOSXE_SIP_SPA-3-EFC_UNPROV_FAIL : Failed to unprovision EFC for VC [chars] (status = [dec])
Explanation

The SPA driver is not able to unprovision EFC for the interface specified in the message. This indicates a hardware error.
Recommended Action

No action is required.
%IOSXE_SIP_SPA-3-C2W_MAIN_INIT_FAIL : Failed to initialize SPA main c2w bus for subslot [dec] (status = [dec])
Explanation

The SPA driver is not able to initialize SPA main c2w. This indicates a hardware error.
Recommended Action

No action is required.
%IOSXE_SIP_SPA-3-NETCLK_FAIL : Failed to [chars] SPA reference clock on [chars]
Explanation

The SPA driver is not able to correctly configure the SPA reference clock on the specified interface. This indicates a hardware
error.
Recommended Action

No action is required.
%IOSXE_SIP_SPA-3-LVLTRTOOBIG : Loveletter length exceeds max, [int] bytes
Explanation

The ASR1000-SIP line card attempted to send a large message to the Route Processor (ASR1000-RP).
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IOSXE_SIP_SPA-3-NODISPATCH : Dispatch vector Null, cmd=[dec], dintf=[dec]
Explanation

No command dispatch vector was found for the specified interface.
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IOSXE_SIP_SPA-3-BADMALUCMD2 : Unsupported MALU cmd/arg0=[hex][hex], arg1arg2=[hex][hex] , hwidb=[chars]
Explanation

The Route Processor (ASR1000-RP) passed down a command that the software was not prepared to handle.
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IOSXE_SIP_SPA-3-BADMALUCMD : Unsupported MALU command [dec], arg=[hex], pascb=[hex]
Explanation

The Route Processor (ASR1000-RP) passed down a command that the software was not prepared to handle.
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IOSXE_SIP_SPA-3-BAD_IFCOMTYPE : Bad ifcom message type=[int]
Explanation

The Route Processor (ASR1000-RP) passed down a message that the software was not prepared to handle.
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IOSXE_SIP_SPA-3-IPCSENDFAIL : Failed to send IPC message [chars]
Explanation

The Linecard failed to send a message to the Route Processor (ASR1000-RP).
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IOSXE_SIP_SPA-3-IPCALLOCFAIL : Failed to allocate IPC buffer [chars]
Explanation

The SPA failed to allocate a buffer for communication with the Route Processor (ASR1000-RP).
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IOSXE_SIP_SPA-3-IPCPORTFAIL : Failed to open IPC port ‘[chars]’ [chars] with error [chars]
Explanation

The RP failed to open a port for communication with a SPA module.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SIP_SPA-3-IPCPORT : Failed to [chars] IPC port ‘[chars]’, error [chars]
Explanation

The Linecard failed to create a port for communication with the Route Processor (ASR1000-RP).
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IOSXE_SIP_SPA-3-FAST_NOTIFY_ERROR : Failed to send fast notification to [chars] for [chars] [chars].
Explanation

The SPA driver failed to deliver a fast notification.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SIP_SPA-6-LOGGERMSGTOOBIG : Logger message length ([int] bytes) exceeds the maximum allowed size
Explanation

The carrier card attempted to send a large message to the Route Processor
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SIP_SPA-3-FRR_CFG_FAIL : Failed to configure fast reroute on [chars]: [chars].
Explanation

The SPA driver failed to configure fast rerouting on an interface.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SIP_SPA-3-APS_CFG_FAIL : Failed to configure APS on [chars]: [chars].
Explanation

The SPA driver failed to configure APS on an interface.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SIP_SPA-3-APS_PGP_FAIL : APS PGP Message send failed toslot/tobay [dec]: [dec].
Explanation

APS PGP between working and protect has failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SIP_SPA-3-MDR_BACKUP_FAIL : Minimal Disruptive Restart backup failed for slot [int], bay [int]; reason ([chars])
Explanation

The SPA driver could not backup data required for Minimal Disruptive Restart process. The Minimal Disruptive Restart process
for the SPA may be terminated as a consequence.
Recommended Action

The Minimal Disruptive Restart backup is stored in RP harddisk or Bootflash. If sufficient space is available on these devices,
copy the error message exactly as it appears, and report it to your technical support representative.
%IOSXE_SIP_SPA-3-MDR_BACKUP_OPEN_FAIL : Failed to open Minimal Disruptive Restart backup for slot [int], bay [int], type
[dec]; reason ([chars])
Explanation

The SPA driver could not open Minimal Disruptive Restart backup file. The Minimal Disruptive Restart process may be terminated
as a consequence.
Recommended Action

The Minimal Disruptive Restart backup is stored in RP harddisk or Bootflash. If sufficient space is available on these devices,
copy the error message exactly as it appears, and report it to your technical support representative.
%IOSXE_SIP_SPA-3-MDR_BACKUP_WRITE_FAIL : Failed to write [dec] bytes to Minimal Disruptive Restart backup[chars] for slot
[int], bay [int], type [dec]; reason ([chars])
Explanation

The SPA driver could not write to Minimal Disruptive Restart backup file. The Minimal Disruptive Restart process may be terminated
as a consequence.
Recommended Action

The Minimal Disruptive Restart backup is stored in RP harddisk or Bootflash. If sufficient space is available on these devices,
copy the error message exactly as it appears, and report it to your technical support representative.
%IOSXE_SIP_SPA-3-MDR_BACKUP_READ_FAIL : Failed to read [dec] from Minimal Disruptive Restart backup for slot [int], bay [int],
type [dec]; reason ([chars])
Explanation

The SPA driver could not read from Minimal Disruptive Restart backup file. The Minimal Disruptive Restart process may be terminated
as a consequence.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SIP_SPA-3-MDR_CONFIG_REPLAY : Configuration replay failed during Minimal Disruptive Restart for slot [int], bay [int];
reason ([chars])
Explanation

The SPA driver failed to process config replay during Minimal Disruptive Restart. The Minimal Disruptive Restart process may
be terminated as a consequence.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SIP_SPA-3-SPA_ETHER_SUSPEND_ERROR : SPA ETHER process suspended too long; totally for [dec] milliseconds
Explanation

The SPA ETHER process is not able to write to ezman as ezman is blocked for writes. Copy the error message exactly as it appears
and report it to your technical support representative.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_SPA

%IOSXE_SPA-3-CREATION_FAILURE : slot=[dec] subslot=[dec], spa_type=[hex], lc_type=[hex].
Explanation

Failed to create a SPA object.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-SPA_CREATION_FAILURE : slot=[dec] subslot=[dec], PID=[chars] lc_type=[hex].
Explanation

Failed to create a SPA object.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-NULL_VFT : [chars] virtual function table is not initialized. spaType=[hex]
Explanation

A required function table is not initialized
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-NULL_VFUNC : [chars] vector is not initialized. spaType=[hex]
Explanation

A required function vector is not initialized
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-MEM_ALLOC_ERROR : [chars]
Explanation

Memory allocation error.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-NULL_SPA_PTR :
Explanation

Pointer to a SPA object is NULL.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-NULL_BAY_PTR :
Explanation

Pointer to SPA bay is NULL.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-INVALID_SLOT_NUM : slot= [dec], max slot = [dec]
Explanation

An invalid slot number is specified in one of the internal APIs.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-INVALID_SUBSLOT_NUM : subslot= [dec], max subslot = [dec]
Explanation

An invalid subslot number is specified in one of the internal APIs.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-INVALID_DB_NUM : db = [dec], max db = [dec], db intf = [dec], max db intf = [dec]
Explanation

An invalid daughter board number is specified in one of the internal APIs.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-INVALID_RP_SLOT_NUM : slot= [dec], max slot = [dec]
Explanation

An invalid RP slot number is specified in one of the internal APIs.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-INVALID_CPU_NUM : cpu= [dec], max cpu = [dec]
Explanation

An invalid CPU number is specified in one of the internal APIs.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-INVALID_SLOTUNIT_NUM : cardwide-port = [dec], max cardwide-port = [dec]
Explanation

An invalid cardwide-port number is specified in one of the internal APIs.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-INVALID_INDX_RANGE : index1= [dec], index2= [dec], maxIndex= [dec]
Explanation

An invalid index range is specified in one of the internal APIs.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-INVALID_IF_INDEX : index= [dec], spaType=[hex], slot [dec] subSlot [dec] slotunit [dec] vc [dec]
Explanation

Index for the interface is not valid.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-INVALID_DATA_INSTANCE : interface type [chars], slot [dec] port [dec] vc [dec] : [chars]
Explanation

Data required to support the interface is not available.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-POWER_CYCLE : [chars] occurred on Shared Port Adapter [int]/[int]
Explanation

An error has occurred which will cause the Shared Port Adapter to be power cycled
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-DIAG_CONFIG : [chars] did not complete [dec]/[dec]
Explanation

An error has occured during diagnostic test.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-UNSUPPORTED_DATA : Data conversion error ([chars], [hex])
Explanation

An internal software error has occured when converting the data specified in the message from one representation to another.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-IPC_FAILURE : IPC failure while [chars]
Explanation

An error has occurred while prepareing or sending an IPC message.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-SENDCFGFAIL : Failed to send configuration for [chars] to carrier-card for subslot=[dec]/[dec]
Explanation

Sending configuration failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-CREATE_TDLH_FAILURE : Failed to create SPA [dec]/[dec] handle
Explanation

Failed to create message handle for SPA communication.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-DOMAIN_TDLH_FAILURE : [chars], rc = [dec]
Explanation

Failed to bind message handle for SPA communication.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-SETUP_TDLH_FAILURE : Failed to set the alloc/free handler for SPA [dec]/[dec] handle
Explanation

Failed to set the alloc/free handler for SPA communication.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-DISPATCH_INIT_TDLH_FAILURE : Failed to initialize dispatch path for SPA [dec]/[dec] handle
Explanation

Failed to initialize dispatch path handle for SPA communication.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-INVALID_SPA_TDL_CCAPI_USAGE :
Explanation

Incorrect usage of an internal API that should only be used on CC.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-6-TDLMSG_INCOMPATIBLE : Failed to copy message [chars] to buffer, not allowed for current domain.
Explanation

Failure to marshal a message indicates an incompatibility with the intended recipient.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-CREATE_TDLMSG_FAILURE : Failed to create [chars] message for [chars].
Explanation

Failed to create/allocate necessary TDL message for SPA communication.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-INVALID_HANDLE : Failed to get a valid IPC handle for type [int], slot [dec], subslot [dec].
Explanation

The client handle was found to be NULL for the given type/slot/subslot.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-6-UPDOWN : Interface [chars], link down due to [chars]
Explanation

Ethernet link is down due to remote/local fault.
Recommended Action

Replace the faulty cable.
%IOSXE_SPA-6-DUAL_RATE_CHANGE : [chars]: [chars]
Explanation

Change in rate of the link.
Recommended Action

No action is required.
%IOSXE_SPA-3-SPA_SETUP_FAILURE : Failed to properly setup for SPA communication on slot [dec], subslot [dec].
Explanation

Discovery of the linux interface used to communicate with a SPA failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SPA-3-ABANDON_SPA_CONFIGURATION : Abandon configuration for subslot [dec]/[dec], the SPA type([dec]) is NOT match
with SUP card.
Explanation

Abandon SPA configuration.
Recommended Action

Please check the startup configuration, use no card command to override wrong card configuration and update card type.

IOSXE_SYS_INFRA

%IOSXE_SYS_INFRA-6-BIPC_READ_ERR : connection read error from [chars], rc [dec], bring down IPC id [dec] for fd [dec] seq
[dec]
Explanation

BIPC error during IPC read
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-6-BIPC_READBUF_ERR : process receive buffer error from [chars], rc [dec], bring down IPC
Explanation

BIPC error during IPC read from buffer
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-6-BIPC_DISCONNECT : disconnect by application for [chars], bring down IPC
Explanation

BIPC disconnect requested by an application
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-6-BIPC_WRITE_ERR : write bipc error for [chars], rc [dec], bring down IPC
Explanation

BIPC error during IPC read
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-6-BIPC_CREATE : bipc connect succeeded for [chars], ipc_ctl_id [dec], ipc_fd [dec], seq [dec]
Explanation

BIPC connect succeeded
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-3-BIPC_CREATE_FAIL : Failed to open IPC port ‘[chars]’ for service ‘[chars]’ with error [chars].
Explanation

BIPC connect failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-3-BIPC_DISCONNECT_FAIL : Failed to disconnect IPC port ‘[chars]’ for service ‘[chars]’ with error [chars].
Explanation

BIPC disconnect failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-4-BIPC_TX_Q_THRESHOLD : BIPC transmit queue threshold reached for the channel ‘[chars]’: ipc_ctl_id [dec]
(ipc_fd [dec], seq_num [dec]), Tx Q size [dec]
Explanation

Large number of unsent IPC messages are queued in a BIPC send buffer
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-4-BIPC_RX_IN_APPL_THRESHOLD : Number of IPC messages held in the application reached the maximum channel
threshold. IPC channel ‘[chars]’: ipc_ctl_id [dec] (ipc_fd [dec], seq_num [dec]), curr IPC msg hel in appl [dec]
Explanation

Application is holding large number of received IPC messages
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-3-EVLIB_EPOLL_ARGS : evGetEpollArgs returned fd [dec]
Explanation

Evlib retuned a huge FD value that IOS can not handle.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-6-EOBC_ADDR_CACHE : EOBC ip-table cache: [chars]
Explanation

Unable to setup internal address for eobc communication
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-3-EOBC_SOCK : Socket event for [chars]
Explanation

An internal socket level event has returned an error which is indicated. This may have been the result of a bind, peek, receive
or send operation with respect to the EOBC interface listed.
Recommended Action

LOG_STD_SH_CMD_ACTION(show eobc, show platform software infrastructure bipc)
%IOSXE_SYS_INFRA-3-EWRITE_EVENT_FD : Write to [chars] wakeup fd failed, errno [dec], current signal/wakeup cnt: [int]/[int]
Explanation

Trigering a thread by writing to its wakeup fd failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-3-EREAD_EVENT_FD : [chars] read from wakeup fd failed, errno [dec]
Explanation

A thread reading from its wakeup fd failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-3-EIOS_POLL : IOS thread poll on event lib and wakeup fds failed, errno [dec]
Explanation

IOS thread poll on event lib and wakeup fds failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-3-EIOS_EVDISPATCH : IOS scheduler event dispatch failed, ev_ret [dec], errno [dec]
Explanation

IOS scheduler event dispatch failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-3-EIOS_EVGETNEXT : IOS scheduler get next event failed, ev_ret [dec], errno [dec]
Explanation

IOS scheduler get next event failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-3-EFP_EVDISPATCH : Fastpath thread event dispatch failed, ev_ret [dec], errno [dec]
Explanation

fastpath thread event dispatch failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-3-EFP_EVGETNEXT : Fastpath thread get next event failed, ev_ret [dec], errno [dec]
Explanation

Fastpath thread get next event failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-3-EFP_EPOLL_WAIT : Fastpath thread epoll wait failed, errno [dec]
Explanation

Fastpath epoll wait failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-3-EFP_TOP_EPOLL_CTL_FAILED : Fastpath thread top level efd epoll [chars] failed, fd [dec], errno [dec]
Explanation

Fastpath top level efd epoll_ctl operation failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-3-EFP_IPC_EPOLL_CTL_FAILED : Fastpath thread [chars] [chars] for IPC channel [chars] (ipc id [dec], ipc
fd [dec], seqnum [dec]) failed, efd [dec], errno [dec]
Explanation

Fastpath epoll_ctl operation for an IPC channel failed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-3-EFP_IPC_EPOLL_NO_IPC_ENTRY : IPC entry not found for ipc fd [dec], seq [dec], events [hex] while processing
[chars] from epoll fd [dec]
Explanation

Fastpath failed to find IPC entry after epoll_wait
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-6-FP_IPC_DISCONNECT : IPC channel disconnect for [chars], ipc_ctl_id [dec], fd [dec], seq_num [dec], loc
[chars], err [dec] ([chars])
Explanation

An IPC channel in fastpath is terminated
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-6-IOS_IPC_CTL_DESTROY : IPC control blk destroy: name [chars], ipc_ctl_id [dec], refcout [dec], need_free
[dec]
Explanation

An IPC control block is requested to be destroyed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-6-IOS_FREE_IPC_CTL : IPC control blk free: name [chars], ipc_ctl_id [dec], refcount [dec]
Explanation

An IPC control block is freed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_SYS_INFRA-4-BIPC_CLEAR_CONN : IPC channel (fd [dec], seq_num [dec]) for service ‘[chars]’ cleared by user
Explanation

BIPC disconnect requested by an user with clear command
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_THROUGHPUT

%IOSXE_THROUGHPUT-3-INVALID_CONFIG : No valid license found for the configured throughput level: [chars] kbps
Explanation

Users has the boot up throughput set to non-default level without having the valid license.
Recommended Action

Install valid throughput license
%IOSXE_THROUGHPUT-3-EULA_NOT_ACCEPTED : The EULA has to be accepted prior to throughput configuration.
Explanation

Users need to accept EULA to activate the license
Recommended Action

Accept EULA for throughput license
%IOSXE_THROUGHPUT-3-CONF_FAILED : Configuration failed. Installed license does not support the throughput level. Please install
the valid license
Explanation

An error occurred when the throughput configuration was attempted.
Recommended Action

%IOSXE_THROUGHPUT-3-INVALID_LEVEL : An invalid throughput level: [chars] kbps was selected.
Explanation

The configured throughput level is unknown
Recommended Action

%IOSXE_THROUGHPUT-6-LEVEL : Throughput level has been set to [dec]00000 kbps
Explanation

Throughput level has been set to a number
Recommended Action

%IOSXE_THROUGHPUT-3-SETUP_FAILED : Throughput level setup failed. Boot up will be at the default throughput
Explanation

An error occurred when licensing tried to setup the througput
Recommended Action

IOSXE_TIMESTAMP_ENGINE

%IOSXE_TIMESTAMP_ENGINE-4-ERROR : NULL
Explanation

An unexpected condition has occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_TIMESTAMP_ENGINE-3-TSU_ERR : An unexpected condition has occurred at module ([chars])
Explanation

An unexpected condition has occurred at the Interface Module TSU.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_UPGRADE_ROMMON through IPA

  • IOSXE_UPGRADE_ROMMON

  • IOSXE_USB

  • IOSXE_UTD

  • IOSXE_VMAN

  • IOSXE_WCCP

  • IOSXE_WD

  • IOS_LICENSE_IMAGE_APPLICATION

  • IOXN_APP

  • IP

  • IPA

IOSXE_UPGRADE_ROMMON

%IOSXE_UPGRADE_ROMMON-0-ROMMON_UPGRADE_FAIL : ROMMON upgrade failed: partition [chars]
Explanation

An attempt to upgrade the ROMmon failed.
Recommended Action

Check the system messages to see if any messages appeared that might indicate the source of the ROMmon problem. If you do
not find any additional information indicating a correctable problem, collect all output on the screen, in particular the
console port output after the upgrade rom-monitor command was entered and the output of show rom-monitor, and provide the
collected information to a Cisco technical support representative.
%IOSXE_UPGRADE_ROMMON-0-ROMMON_LOADTEST_FAIL : ROMMON FIPS_140-3 Load test *FAILED*: file [chars]
Explanation

FIPS 140-3 Related Load test failed for the ROMmon.
Recommended Action

Check the system messages to see if any messages appeared that might indicate the source of the ROMmon Load test problem.
If you do not find any additional information indicating a correctable problem, collect all output on the screen, in particular
the console port output after the upgrade rom-monitor command was entered and the output of show rom-monitor, and provide
the collected information to a Cisco technical support representative.

IOSXE_USB

%IOSXE_USB-3-ESHOW_USB : Internal Error locating database for USB Devices.
Explanation

The mcp_usb_devices is incorrect and needs to be changed
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_UTD

%IOSXE_UTD-3-ALLOC : Failed to allocate message
Explanation

When attempting to program the dataplane there was not enough memory to allocate the message.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_UTD-3-MESSAGE : Failed to send message
Explanation

When the message was being prepared for sending to the data plane, there was an error.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_UTD-4-VERSION_INCOMPATIBILITY : UTD package version [chars] does not match recommended UTD package version [chars]
Explanation

The UTD package version does not match the recommended UTD package version embedded in this IOS-XE version.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_UTD-2-VERSION_UNSUPPORTED : UTD package version [chars] is not supported, recommended version is [chars]
Explanation

The UTD package version does not match the required UTD version embedded in this IOS-XE version. This is an unsupported configuration
and may behave unexpectedly.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_UTD-4-SIG_UPDATE_CFG : UTD signature updates have been configured — A brief service interruption at the time of update
is expected
Explanation

The UTD service will be restarted if a new signature package is found. During this time, if fail-close has been configured
(recommended), traffic that would be inspected by UTD will be dropped. Otherwise (default), traffic that would be inspected
by UTD will be allowed to pass uninspected. To minimize this service interruption, it is recommended to schedule this operation
outside of normal business hours.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_UTD-4-SIG_UPDATE_EXEC : UTD signature update has been executed — A brief service interruption is expected
Explanation

The UTD service will be restarted if a new signature package is found. During this time, if fail-close has been configured
(recommended), traffic that would be inspected by UTD will be dropped. Otherwise (default), traffic that would be inspected
by UTD will be allowed to pass uninspected. To minimize this service interruption, it is recommended to execute this operation
outside of normal business hours.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_UTD-4-MT_CONFIG_DOWNLOAD : UTD MT configuration download has [chars]
Explanation

In UTD multitenancy mode, the configuration download to the container can take a while. Please be patient.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_UTD-4-MT_CONTAINER_MESSAGE_TIMEOUT : UTD message sent to the container has timed out
Explanation

The UTD message sent to the container has timed out.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_UTD-4-MT_CONTAINER_MESSAGE_NAK : Container responded to UTD message with an error: [dec]
Explanation

The container rejected the UTD message
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_UTD-4-MT_CONTAINER_SESSION_TIMEOUT : UTD container download has timed out
Explanation

The container did not respond with an up/down status before the session timed out.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_UTD-4-MT_CONTAINER_STATUS_DOWN : UTD poll: container status is DOWN
Explanation

The container sent a down status to the poll message
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_VMAN

%IOSXE_VMAN-3-MSGINITFAIL : Failed to initialize required Virt-manager resource: [chars]
Explanation

During the initialization of the resources required by Virt-manager, a failure occurred. This has prevented virtual services
from being activated.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_VMAN-3-MSGDISPATCH : Unable to dispatch received TDL message from Virt-manager
Explanation

An unexpected condition has occurred while IOS was trying to dispatch a TDL message received from Virt-manager.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_VMAN-3-RSPMSGHDLR : Failed to deliver response message: [chars]
Explanation

An unexpected condition has occurred while IOS was trying to deliver a response message to a virtual service received from
Virt-manager.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_WCCP

%IOSXE_WCCP-4-NOINPUT : NULL input, [chars]
Explanation

An unexpected condition has occurred which is due to the NULL value of the input parameter.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show ip wccp command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_WCCP-4-NOSVCGRP : [chars] Service Group ([dec], [dec], [int]) NOT exist
Explanation

An unexpected condition has occurred which is due to the absence of the service group structure.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show ip wccp command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_WCCP-4-NOACL : Access list is null
Explanation

An unexpected condition has occurred which is due to the absence of an access list structure.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show ip access-lists command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_WCCP-4-ACELIMIT : Too many ACEs in MASK ACL, please switch to Hash mode
Explanation

Mask merged ACL generate too many ACEs.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show ip access-lists command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_WCCP-4-BADACE : Access list contains invalid ace
Explanation

An unexpected condition has occurred which is due to an invalid statement in the access list structure.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show ip access-lists command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_WCCP-4-NOINTF : No [chars] interface info for Service Group ([dec], [dec], [int])
Explanation

An unexpected condition has occurred which is due to the absence of MCP WCCP interface info for the specific service group.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show platform software wccp command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_WCCP-4-UNKNOWNDIR : Unknown [chars] interface direction [hex] for Service Group ([dec], [dec], [int])
Explanation

An unexpected condition has occurred which is due to the unknown direction has been applied to the interface for the service
group.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show platform software wccp command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_WCCP-4-NOSTATS : WCCP [chars] message error
Explanation

An unexpected condition has occurred which is due to the error in receiving WCCP stats update message.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show platform software wccp <id> counters command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_WCCP-4-NOSTATSSVC : Service Group ([dec], [dec], [int]) not exist for the stats message
Explanation

An unexpected condition has occurred which can’t find the service group for the service group stats message.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show platform software wccp command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOSXE_WCCP-4-NOSTATSINTF : Interface handle [int] not exsit for the stats message
Explanation

An unexpected condition has occurred which can’t find the interface handle for the interface stats message.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show platform software wccp <id> int counters command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.

IOSXE_WD

%IOSXE_WD-2-HEARTBEAT_FAIL : Heartbeat is not emitted. Heartbeat count:[dec]
Explanation

Failure in IOS to generate a heartbeat is an abnormal condition
Recommended Action

This message may be related to an abnormal configuration and system load, or transient high processing demand. When reporting
this message, copy the message text exactly as it appears, include the stack trace and report to your technical support representative
%IOSXE_WD-2-HOG_DETECT_FAIL : CPUHOG detection failed to start.
Explanation

Failure in setting up CPUHOG detection mechanism is an abnormal condition
Recommended Action

This message may be related to an abnormal configuration and system load, or transient high processing demand. When reporting
this message, copy the message text exactly as it appears, include the stack trace and report to your technical support representative

IOS_LICENSE_IMAGE_APPLICATION

%IOS_LICENSE_IMAGE_APPLICATION-3-FAILED : [chars]
Explanation

The ios licensing subsystem failed to create a process/watched boolean etc to watch request from the remote show subsys license
commands
Recommended Action

please capture the error msg and forward it to the appropriate licensing component
%IOS_LICENSE_IMAGE_APPLICATION-3-UNKNOWN_EVENT : [chars]
Explanation

The ios image licensing subsystem received an event which it does not understand or recognizes
Recommended Action

please capture the error msg and forward it to the appropriate licensing component
%IOS_LICENSE_IMAGE_APPLICATION-3-UNKNOWN_VERSION : [chars]
Explanation

Recommended Action

%IOS_LICENSE_IMAGE_APPLICATION-6-NO_LICENSE : No valid license available: [chars] = [chars]; [chars] = [dec]; [chars] = [chars]:[chars]
Explanation

The ios image licensing subsystem received an event for an unknown version of a feature There is no valid license available
on the box and we are running on a default feature
Recommended Action

please capture the error msg and forward it to the appropriate licensing component please purchase a license to activate required
features
%IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL : Module name = [chars] Next reboot level = [chars] and License = [chars]
Explanation

This is an informational message to display the change in the next reboot license level
Recommended Action

This is an informational message, no action is required
%IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_LEVEL_CONFIG : Please issue ‘license boot’ config command to make extension license
([chars]) available for use.
Explanation

This is an informational message to info user that to make extension license available to support image level, licensing image
level needs to be configured
Recommended Action

This is an informational message, no action is required
%IOS_LICENSE_IMAGE_APPLICATION-6-LICENSE_CONFIG : EULA must be accepted for license level = [chars]
Explanation

This is an informational message to inform user that the user needs to reissue the command from an interactive terminal
Recommended Action

This is an informational message, no action is required

IOXN_APP

%IOXN_APP-3-INITFAIL : Failed to create chasfs property ioxman (rc =[chars]) or caf (rc = [chars]) is not up
Explanation

An unexpected condition resulted into failure to start an application.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOXN_APP-3-CLEANUPFAIL : Failed to create chasfs property to indicate cleanup of previous app installation (rc = [chars])
Explanation

An unexpected condition resulted in failure to setup the start of an application.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOXN_APP-3-GSFAIL : [chars] [int]
Explanation

An unexpected condition resulted into failure to start an application.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOXN_APP-3-CFGFAIL : [chars] [chars]
Explanation

An unexpected condition resulted into failure to apply auto config
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOXN_APP-3-PREVOPFAIL : Overriding previous operation ([chars] iox) that is taking longer than [int] secs to complete
Explanation

An unexpected condition resulted in failure to apply iox config
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOXN_APP-3-MSGFAIL : Message dispatch failure ([chars]).
Explanation

Message could not be dispatched to an application.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOXN_APP-6-STARTUP_CONFIG_INFO : [chars]
Explanation

Informational logs for startup config injection.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOXN_APP-6-STARTUP_CONFIG_CHASSIS_INFO : [chars] [dec]/[chars]/[dec]/[dec]
Explanation

Chassis information at startup config injection.
Recommended Action

No action is required.
%IOXN_APP-3-STARTUP_CONFIG_FAIL : [chars] [chars]
Explanation

Error while creating startup config
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOXN_APP-3-IPCINITFAIL : [chars]
Explanation

A critical IPC initialization error occured
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IOXN_APP-6-SLOT_NOTIFICATION : [chars] [dec]
Explanation

Slot addition or removal information
Recommended Action

No action is required.

IP

%IP-4-CLASS : Bad IP address and mask [IP_address]%m in class_resolve()
Explanation

An internal software error occurred.
Recommended Action

If this message recurs, copy the error message exactly as it appears on the console or in the system log. Perform a search
of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IP-4-DUPADDR : Duplicate address [IP_address] on [chars], sourced by [enet]
Explanation

Another system is using your IP address.
Recommended Action

Change the IP address of one of the two systems.
%IP-4-ZERO_ADDR : Zero MAC address for [IP_address] in ARP cache
Explanation

An entry in the ARP cache have a NULL MAC address
Recommended Action

If this message recurs, call your technical support representative for assistance.
%IP-3-DESTHOST : src=[IP_address], dst=[IP_address], NULL desthost
Explanation

An internal software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IP-3-BADIPALIGN : Invalid alignment in packet for IP. [chars]=[hex]
Explanation

The packet data structure is misaligned. This condition may result in a small amount of overhead in processing IP traffic.
Recommended Action

Enter a show hardware command and report the output, along with this error message, to your technical support representative.
%IP-3-BADSROUTE : Improper source route. Length [dec] Ptr [dec]
Explanation

A hardware or software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IP-6-PHYBCASTDROP : Physical broadcast packet detected and dropped, src=[IP_address], dst=[IP_address]
Explanation

Physical broadcast packet was dropped.
Recommended Action

No action is required.
%IP-6-L2MCASTDROP : Layer 2 Multicast packet detected and dropped, src=[IP_address], dst=[IP_address]
Explanation

Layer 2 Multicast packet with Layer3 Unicast Destination was dropped.
Recommended Action

No action is required.
%IP-3-LOOPPAK : Looping packet detected and dropped — src=[IP_address], dst=[IP_address], hl=[int], tl=[int], prot=[int],
sport=[int], dport=[int] in=[chars], nexthop=[IP_address], out=[chars]options=[chars]
Explanation

A software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IP-5-WEBINST_START : Attempting web install from host [IP_address]
Explanation

A hardware or software error occurred.
Recommended Action

Copy the error message exactly as it appears, and report it to your technical support representative.
%IP-5-WEBINST_KILL : Terminating DNS process
Explanation

A hardware or software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IP-5-WEBINST_COMP : Selected IP address [IP_address]
Explanation

A hardware or software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IP-5-WEBINST_RESP : Sending DNS response to [IP_address] (request was for [IP_address])
Explanation

A hardware or software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IP-3-CNTRFULL : IP counter block is full (setting protocol [dec])
Explanation

An internal software error occured.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IP-5-TURBOACL : [chars]
Explanation

Error occured in intialisation of TURBOACL.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show process command to gather data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IP-5-ACL : [chars]
Explanation

Error occured in IP access checks.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IP-4-UNICASTRPF : IP unicast reverse-path check disabled on [chars]
Explanation

The IP verify unicast reverse-path feature was disabled because CEF was disabled (either through configuration or due to an
internal error.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IP-3-LOOPOUTIF : Output interface for packet has been changed for [dec] times and dropped — src=[IP_address], dst=[IP_address],
hl=[int], tl=[int], prot=[int], in=[chars], nexthop=[IP_address], out=[chars]
Explanation

A software error occurred.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IP-3-MAXIRDP : Attempt to send IRDP to proxies exceeding configurable limit: [dec], interface: [chars], secondary = [dec],
proxy = [dec]
Explanation

The sum of configured secondary addresses and configured proxy addresses exceeds the number of total addresses that the IRDP
can support in its implementation.
Recommended Action

Reduce the number of either the secondary IP addresses or proxy addresses configured for the interface.
%IP-4-IPPOOLS : Detected a local pool and a DHCP pool with the same name: [chars]
Explanation

A local pool and a DHCP pool have been configured with the same name. This may cause conflict during address allocations.
Recommended Action

Change the name of one of the two pools
%IP-3-ICMPRATELIMIT : [int]nreachables rate-limited within [int] milliseconds on [chars]. [int] log messages suppressed since
last log message displayed on [chars]
Explanation

An excessive number of packets are triggering log messages on this interface
Recommended Action

change the log threshold with the icmp rate-limit command or find the source of the packets and block the packets from this
router
%IP-3-ICMPRATELIMITDF : [int] DF unreachables rate-limited within [int] milliseconds on [chars]. [int] DF log messages suppressed
since last log message displayed on [chars]
Explanation

An excessive number of packets are triggering log messages on this interface
Recommended Action

change the log threshold with the icmp rate-limit command or find the source of the packets and block the packets from this
router
%IP-3-NOOUTINTF : Output interface not available. source address: [IP_address], destination address: [IP_address], routing
type: [int]
Explanation

The output interface for this packet is not set
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IP-3-NONALIAS : non-alias address [IP_address] in table [chars] found in IP alias list
Explanation

The IP alias list holds IP aliases only but non-alias entries are found.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IP-3-IPTOPOID : Topology ID [hex] is invalid, can’t get the base topology ID.
Explanation

An internal software error occurred
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.
%IP-3-SBINIT : Error initializing [chars] subblock data structure. [chars]
Explanation

Initialization of the specified subblock data structure could not be accomplished.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case), or contact your Cisco technical support representative and provide the representative with the gathered information.

IPA

%IPA-3-PORTCONN : bay [[int]] failed to establish [chars] connection ([hex])
Explanation

An attempt to establish the console or debugger connection with the channel port adapter failed.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IPA-3-PORTIOKILL : Port IO [chars] process terminating.
Explanation

Unexpected termination of a port io process.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IPA-3-NEVER : bay [[chars]] mailbox response timed out after ([int] + [int]) usecs, mbx=[hex]
Explanation

A mailbox command sent from driver to the channel port adapter never completed within the expected time limit. As a result
of this error, the channel port adapter driver will reset the port adapter and reload microcode to it.
Recommended Action

The reset and reload rectified the problem. If that did not occur, then try the microcode reload operation again. <Body><par>If the error still occurs, record the output from the following commands: <Bullet><par>show tech <Bullet><par>dir slot0: <Bullet><par>dir slot1: <Bullet><par>show log <Body><par>Provide this information to your technical support representative.
%IPA-3-UKNMBXCMD : [chars]: unknown mailbox command: [hex] [hex] [hex] [hex]
Explanation

The channel port adapter sent a mailbox command that the driver did not expect. This may occur if there is a version mismatch
between the system image and the microcode.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.
%IPA-3-INVMBXCMD : [chars]: invalid mailbox command: [hex]
Explanation

A subsytem attempted to register a mailbox command that is out of range.
Recommended Action

Copy the error message exactly as it appears on the console or in the system log. Issue the show tech-support command to gather
data that may help identify the nature of the error. Also perform a search of the Bug Toolkit (https://bst.cloudapps.cisco.com/bugsearch/). If you still require assistance, open a case with the Technical Assistance Center via the Internet (https://mycase.cloudapps.cisco.com/case) , or contact your Cisco technical support representative and provide the representative with the gathered information.

Stumped: gbic-invalid error, bad crc — anyone see this before?

so I’ve been successfully able to make a fiber etherchannel between my 3750G’s upon themselves, but I’m trying to connect the 3750G (Master) in a uplink to my HP Procurve 2910al and I’m getting a bad crc error:

00:10:02: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port 65564 has bad crc
00:10:02: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/28, putting Gi1/0/28 in err-disable state
00:10:04: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/28, changed state to down

.
here is the config on the 3750G — it’s a factory reset, basic config only. anyone see something I’m missing? — at the bottom will be the HP Procurve. Only thing I can think of is maybe the 3750G needs a firmware update. I’ve tried a Netgear, Dell, and HP Gbic stick and they all give the same crc. Even brand-new Netgeat carrot sticks; i’m perplexed.
Switch#
Switch#show ver
Cisco IOS Software, C3750 Software (C3750-IPBASEK9-M), Version 12.2(25)SEB1, RELEASE SOFTWARE (fc1)
Copyright (c) 1986-2005 by Cisco Systems, Inc.
Compiled Sat 30-Apr-05 02:33 by yenanh

ROM: Bootstrap program is C3750 boot loader
BOOTLDR: C3750 Boot Loader (C3750-HBOOT-M) Version 12.1(14r)EA1a, RELEASE SOFTWARE (fc1)

Switch uptime is 8 hours, 12 minutes
System returned to ROM by power-on
System image file is «flash:c3750-ipbasek9-mz.122-25.SEB1/c3750-ipbasek9-mz.122-25.SEB1.bin»

This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.

Switch#
Switch#
Switch#
Switch#

Switch>
Switch>
Switch>
Switch>
Switch>
Switch>enable
Switch#
Switch#
Switch#
Switch#
Switch#
Switch#
Switch#
Switch#show config
Using 1891 out of 524288 bytes
!
version 12.2
no service pad
service timestamps debug uptime
service timestamps log uptime
no service password-encryption
!
hostname Switch
!
!
no aaa new-model
switch 1 provision ws-c3750g-24ts
ip subnet-zero
ip routing
!
!
!
!
!
!
no file verify auto
spanning-tree mode pvst
spanning-tree extend system-id
!
vlan internal allocation policy ascending
!
interface Port-channel1
switchport trunk encapsulation dot1q
switchport mode trunk
!
interface GigabitEthernet1/0/1
!
interface GigabitEthernet1/0/2
!
interface GigabitEthernet1/0/3
!
interface GigabitEthernet1/0/4
!
interface GigabitEthernet1/0/5
!
interface GigabitEthernet1/0/6
!
interface GigabitEthernet1/0/7
!
interface GigabitEthernet1/0/8
!
interface GigabitEthernet1/0/9
!
interface GigabitEthernet1/0/10
!
interface GigabitEthernet1/0/11
!
interface GigabitEthernet1/0/12
!
interface GigabitEthernet1/0/13
!
interface GigabitEthernet1/0/14
!
interface GigabitEthernet1/0/15
!
interface GigabitEthernet1/0/16
!
interface GigabitEthernet1/0/17
!
interface GigabitEthernet1/0/18
!
interface GigabitEthernet1/0/19
!
interface GigabitEthernet1/0/20
switchport mode access
!
interface GigabitEthernet1/0/21
switchport mode access
!
interface GigabitEthernet1/0/22
switchport mode access
!
interface GigabitEthernet1/0/23
switchport mode access
!
interface GigabitEthernet1/0/24
switchport mode access
!
interface GigabitEthernet1/0/25
!
interface GigabitEthernet1/0/26
!
interface GigabitEthernet1/0/27
!
interface GigabitEthernet1/0/28
switchport trunk encapsulation dot1q
switchport mode trunk
channel-group 1 mode active
!
interface Vlan1
description ‘Primary Vlan’
no ip address
!
interface Vlan100
ip address 192.168.225.31 255.255.255.192
ip helper-address 192.168.225.1
!
ip classless
ip http server
ip http secure-server
!
!
control-plane
!
!
line con 0
line vty 0 4
no login
line vty 5 15
no login
!
!
end

Switch#show inter giga1/0/28
GigabitEthernet1/0/28 is down, line protocol is down (err-disabled)
Hardware is Gigabit Ethernet, address is 0013.c444.809c (bia 0013.c444.809c)
MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive not set
Auto-duplex, Auto-speed, link type is auto, media type is unknown
input flow-control is off, output flow-control is unsupported
ARP type: ARPA, ARP Timeout 04:00:00
Last input never, output never, output hang never
Last clearing of «show interface» counters never
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: fifo
Output queue: 0/40 (size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts (0 multicast)
0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 watchdog, 0 multicast, 0 pause input
0 input packets with dribble condition detected
0 packets output, 0 bytes, 0 underruns
—More—

Switch#
Switch#config t
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#inter giga1/0/28
Switch(config-if)#no shut
Switch(config-if)#exit
Switch(config)#exit
Switch#show inter giga1/0/28
08:18:43: %SYS-5-CONFIG_I: Configured from console by console
GigabitEthernet1/0/28 is down, line protocol is down (err-disabled)
Hardware is Gigabit Ethernet, address is 0013.c444.809c (bia 0013.c444.809c)
MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive not set
Auto-duplex, Auto-speed, link type is auto, media type is unknown
input flow-control is off, output flow-control is unsupported
ARP type: ARPA, ARP Timeout 04:00:00
Last input never, output never, output hang never
Last clearing of «show interface» counters never
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: fifo
Output queue: 0/40 (size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts (0 multicast)
0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 watchdog, 0 multicast, 0 pause input
0 input packets with dribble condition detected
0 packets output, 0 bytes, 0 underruns
—More—

@ @
File «flash:c3750-ipbasek9-mz.122-25.SEB1/c3750-ipbasek9-mz.122-25.SEB1.bin» unc ompressed and installed, entry point: 0x3000
executing.

Restricted Rights Legend

Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software — Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.

cisco Systems, Inc.
170 West Tasman Drive
San Jose, California 95134-1706

Cisco IOS Software, C3750 Software (C3750-IPBASEK9-M), Version 12.2(25)SEB1, REL EASE SOFTWARE (fc1)
Copyright (c) 1986-2005 by Cisco Systems, Inc.
Compiled Sat 30-Apr-05 02:33 by yenanh
Image text-base: 0x00003000, data-base: 0x00DB5330

flashfs[1]: 358 files, 5 directories
flashfs[1]: 0 orphaned files, 0 orphaned directories
flashfs[1]: Total bytes: 15998976
flashfs[1]: Bytes used: 7683072
flashfs[1]: Bytes available: 8315904
flashfs[1]: flashfs fsck took 4 seconds.
flashfs[1]: Initialization complete. done Initializing flashfs.

POST: CPU MIC register Tests : Begin
POST: CPU MIC register Tests : End, Status Passed

POST: PortASIC Memory Tests : Begin
POST: PortASIC Memory Tests : End, Status Passed

POST: CPU MIC PortASIC interface Loopback Tests : Begin
POST: CPU MIC PortASIC interface Loopback Tests : End, Status Passed

POST: PortASIC RingLoopback Tests : Begin
POST: PortASIC RingLoopback Tests : End, Status Passed

Waiting for Stack Master Election (around 30 seconds).
POST: PortASIC CAM Subsystem Tests : Begin
POST: PortASIC CAM Subsystem Tests : End, Status Passed

POST: No Cable found on stack port 1
POST: No Cable found on stack port 2

POST: PortASIC Stack Port Loopback Tests : Begin
POST: PortASIC Stack Port Loopback Tests : End, Status Passed

POST: PortASIC Port Loopback Tests : Begin
POST: PortASIC Port Loopback Tests : End, Status Passed

Election Complete
Switch 1 booting as Master
Waiting for Port download. Complete

This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.

A summary of U.S. laws governing Cisco cryptographic products may be found at:
Export Compliance Product Report Application

If you require further assistance please contact us by sending email to
[email protected] .

cisco WS-C3750G-24TS (PowerPC405) processor (revision H0) with 118784K/12280K by tes of memory.
Processor board ID CAT0916Y04G
Last reset from power-on
1 Virtual Ethernet interface
28 Gigabit Ethernet interfaces
The password-recovery mechanism is enabled.

512K bytes of flash-simulated non-volatile configuration memory.
Base ethernet MAC Address : 00:13:C4:44:80:80
Motherboard assembly number : 73-7058-12
Power supply part number : 341-0045-01
Motherboard serial number : CAT091605VP
Power supply serial number : LIT091003WE
Model revision number : H0
Motherboard revision number : A0
Model number : WS-C3750G-24TS-S
System serial number : CAT0916Y04G
Hardware Board Revision Number : 0x09

Switch Ports Model SW Version SW Image * 1 28 WS-C3750G-24TS 12.2(25)SEB1 C3750-IPBASEK9-M

Failed to generate persistent self-signed certificate.
Secure server will use temporary self-signed certificate.

Press RETURN to get started!

00:01:25: %STACKMGR-6-SWITCH_ADDED: Switch 1 has been ADDED to the stack
00:01:26: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state t o down
00:01:28: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
00:01:30: %SYS-5-CONFIG_I: Configured from memory by console
00:01:30: %STACKMGR-6-SWITCH_READY: Switch 1 is READY
00:01:30: %STACKMGR-6-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to st ate DOWN
00:01:30: %STACKMGR-6-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to st ate DOWN
00:01:30: %STACKMGR-6-MASTER_READY: Master Switch 1 is READY
00:01:30: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port 65564 has bad c rc
00:01:30: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/28, putting Gi 1/0/28 in err-disable state
00:01:30: %SYS-5-RESTART: System restarted —
Cisco IOS Software, C3750 Software (C3750-IPBASEK9-M), Version 12.2(25)SEB1, REL EASE SOFTWARE (fc1)
Copyright (c) 1986-2005 by Cisco Systems, Inc.
Compiled Sat 30-Apr-05 02:33 by yenanh
Switch>
Switch>enable
Switch#config t
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#inter giga1/0/28
Switch(config-if)#keep
Switch(config-if)#keepalive 10
Switch(config-if)#exit
Switch(config)#exit
Switch#wr
00:09:17: %SYS-5-CONFIG_I: Configured from console by consoleme
Translating «wrme». domain server (255.255.255.255)
% Unknown command or computer name, or unable to find computer address
Switch#
Switch#
Switch#copy
Switch#copy ru
Switch#copy running-config st
Switch#copy running-config startup-config
Destination filename [startup-config]?
Building configuration.
[OK]
Switch#
Switch#
Switch#
Switch#config t
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#inter giga1/0/28
Switch(config-if)#shut
Switch(config-if)#no
00:09:58: %LINK-5-CHANGED: Interface GigabitEthernet1/0/28, changed state to administratively downshut
Switch(config-if)#
00:10:02: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port 65564 has bad crc
00:10:02: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/28, putting Gi1/0/28 in err-disable state
00:10:04: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/28, changed state to down

Switch>$col on Interface Vlan1, changed state t o down
00:01:26: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state t^ o down

% Invalid input detected at ‘^’ marker.

Switch>$SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
00:01:28: %SPANTREE-5-EXTENDED_SYSID: Extended SysId enabled for type vlan
^
% Invalid input detected at ‘^’ marker.

Switch>00:01:30: %SYS-5-CONFIG_I: Configured from memory by console
^
% Invalid input detected at ‘^’ marker.

Switch>00:01:30: %STACKMGR-6-SWITCH_READY: Switch 1 is READY
^
% Invalid input detected at ‘^’ marker.

Switch>$Stack Port 1 Switch 1 has changed to st ate DOWN
00:01:30: %STACKMGR-6-STACK_LINK_CHANGE: Stack Port 1 Switch 1 has changed to st^ ate DOWN

% Invalid input detected at ‘^’ marker.

Switch>$Stack Port 2 Switch 1 has changed to st ate DOWN
00:01:30: %STACKMGR-6-STACK_LINK_CHANGE: Stack Port 2 Switch 1 has changed to st^ ate DOWN

% Invalid input detected at ‘^’ marker.

Switch>00:01:30: %STACKMGR-6-MASTER_READY: Master Switch 1 is READY
^
% Invalid input detected at ‘^’ marker.

Switch>$CRC_ERROR: GBIC in port 65564 has bad c rc
00:01:30: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port 65564 has bad c^ rc

% Invalid input detected at ‘^’ marker.

Switch>$i1/0/28, putting Gi 1/0/28 in err-disable state
00:01:30: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/28, putting Gi^ 1/0/28 in err-disable state

% Invalid input detected at ‘^’ marker.

Switch>00:01:30: %SYS-5-RESTART: System restarted —
^
% Invalid input detected at ‘^’ marker.

Switch>$n 12.2(25)SEB1, REL EASE SOFTWARE (fc1)
Cisco IOS Software, C3750 Software (C3750-IPBASEK9-M), Version 12.2(25)SEB1, REL ^ EASE SOFTWARE (fc1)

% Invalid input detected at ‘^’ marker.

Switch>Copyright (c) 1986-2005 by Cisco Systems, Inc.
^
% Invalid input detected at ‘^’ marker.

Switch>Compiled Sat 30-Apr-05 02:33 by yenanh
^
% Invalid input detected at ‘^’ marker.

Switch>$abitEthernet1/0/23, changed state to up
00:01:33: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/23,^ changed state to up

% Invalid input detected at ‘^’ marker.

Switch>$LINK-3-UPDOWN: Interface GigabitEthernet1/0/23, changed state to up
00:01:34: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/23, changed state to up
^
% Invalid input detected at ‘^’ marker.

Switch>$col on Interface Vlan1, changed state t o up
00:02:03: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state t^ o up

% Invalid input detected at ‘^’ marker.

Switch>
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>enable
Switch#config t
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#inter giga1/0/28
Switch(config-if)#keep
Switch(config-if)#keepalive 10
Switch(config-if)#exit
Switch(config)#exit
Switch#wr
00:09:17: %SYS-5-CONFIG_I: Configured from console by consoleme
Translating «wrme». domain server (255.255.255.255)
% Unknown command or computer name, or unable to find computer address
Switch#
Switch#
Switch#copy
Switch#copy ru
Switch#copy running-config st
Switch#copy running-config startup-config
Destination filename [startup-config]?
Building configuration.
[OK]
Switch#
Switch#
Switch#
Switch#config t
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#inter giga1/0/28
Switch(config-if)#shut
Switch(config-if)#no
00:09:58: %LINK-5-CHANGED: Interface GigabitEthernet1/0/28, changed state to administratively downshut
Switch(config-if)#
00:10:02: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port 65564 has bad crc
00:10:02: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/28, putting Gi1/0/28 in err-disable state
00:10:04: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/28, changed state to down
00:13:57: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port 65564 has bad crc
Switch(config-if)#
Switch(config-if)#
Switch(config-if)#
Switch(config-if)#
00:15:17: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port 65562 has bad crc
00:15:17: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/26, putting Gi1/0/26 in err-disable state
00:15:37: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port 65561 has bad crc
00:15:37: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/25, putting Gi1/0/25 in err-disable state

Switch con0 is now available

Press RETURN to get started.

00:24:20: %SYS-5-CONFIG_I: Configured from console by console
Switch>
Switch>
Switch>
Switch>
Switch>
Switch>enable
Switch#show ip inter br
Interface IP-Address OK? Method Status Protocol
Vlan1 unassigned YES NVRAM up up
Vlan100 192.168.225.31 YES NVRAM up down
GigabitEthernet1/0/1 unassigned YES unset down down
GigabitEthernet1/0/2 unassigned YES unset down down
GigabitEthernet1/0/3 unassigned YES unset down down
GigabitEthernet1/0/4 unassigned YES unset down down
GigabitEthernet1/0/5 unassigned YES unset down down
GigabitEthernet1/0/6 unassigned YES unset down down
GigabitEthernet1/0/7 unassigned YES unset down down
GigabitEthernet1/0/8 unassigned YES unset down down
GigabitEthernet1/0/9 unassigned YES unset down down
GigabitEthernet1/0/10 unassigned YES unset down down
GigabitEthernet1/0/11 unassigned YES unset down down
GigabitEthernet1/0/12 unassigned YES unset down down
GigabitEthernet1/0/13 unassigned YES unset down down
GigabitEthernet1/0/14 unassigned YES unset down down
GigabitEthernet1/0/15 unassigned YES unset down down
GigabitEthernet1/0/16 unassigned YES unset down down
GigabitEthernet1/0/17 unassigned YES unset down down
GigabitEthernet1/0/18 unassigned YES unset down down
GigabitEthernet1/0/19 unassigned YES unset down down
GigabitEthernet1/0/20 unassigned YES unset down down
GigabitEthernet1/0/21 unassigned YES unset down down
GigabitEthernet1/0/22 unassigned YES unset down down
GigabitEthernet1/0/23 unassigned YES unset up up
GigabitEthernet1/0/24 unassigned YES unset down down
GigabitEthernet1/0/25 unassigned YES unset down down
GigabitEthernet1/0/26 unassigned YES unset down down
GigabitEthernet1/0/27 unassigned YES unset down down
GigabitEthernet1/0/28 unassigned YES unset down down
Port-channel1 unassigned YES unset down down
Switch#
Switch#
Switch#
Switch#
Switch#
Switch#
Switch#

ProCurve J9148A 2910al-48G-PoE Switch
Software revision W.14.49

Copyright (C) 1991-2010 Hewlett-Packard Co. All Rights Reserved.

RESTRICTED RIGHTS LEGEND

Use, duplication, or disclosure by the Government is subject to restrictions
as set forth in subdivision (b) (3) (ii) of the Rights in Technical Data and
Computer Software clause at 52.227-7013.

HEWLETT-PACKARD COMPANY, 3000 Hanover St., Palo Alto, CA 94303

We’d like to keep you up to date about:
* Software feature updates
* New product announcements
* Special events

Please register your products now at: www.ProCurve.com

Smith-MDF# show config

; J9148A Configuration Editor; Created on release #W.14.49

hostname «Smith-MDF»
module 1 type J9148A
interface 25
disable
exit
interface 46
disable
exit
interface 48
disable
exit
trunk 47 Trk2 LACP
ip default-gateway 192.168.225.1
ip routing
vlan 1
name «DATA-vlan»
untagged 25-26,44,48
no untagged 1-24,27-43,45-46,Trk2
no ip address
exit
vlan 2
name «smith-camera’s»
untagged 35-36,39-40
ip address 192.200.102.1 255.255.255.224
exit
vlan 4
name «disabled-ports»
untagged 46
no ip address
exit
vlan 15
name «Wireless»
untagged 30-34
ip helper-address 172.16.35.8
ip address 172.16.35.2 255.255.255.224
exit
vlan 5
name «dell switch»
untagged 37-38,45
ip helper-address 192.168.2.6
ip address 192.168.2.5 255.255.255.0
exit
vlan 100
name «Primary-Vlan»
untagged 1-24,27-29,41-43,Trk2
ip helper-address 192.168.225.1
ip address 192.168.225.15 255.255.255.192
exit
ip route 0.0.0.0 0.0.0.0 192.168.225.1
ip route 172.16.7.0 255.255.255.0 192.225.225.6
ip route 172.16.8.0 255.255.255.0 192.225.225.6
ip route 172.16.35.0 255.255.255.224 172.16.35.3
ip route 192.168.102.0 255.255.255.0 192.225.225.6
ip route 192.168.104.0 255.255.255.0 192.225.225.6
ip route 192.168.106.0 255.255.255.0 192.225.225.6
ip route 192.168.108.0 255.255.255.0 192.225.225.6
ip route 192.168.120.0 255.255.255.0 192.225.225.6
ip route 192.168.130.0 255.255.255.0 192.225.225.6
snmp-server community «public» unrestricted
spanning-tree
spanning-tree Trk2 priority 4
primary-vlan 100
management-vlan 100
no autorun
password manager

Smith-MDF#
Smith-MDF#
Smith-MDF#

Источник

Hi We are having an issue with a 3750X. 7 Ports are down showing the same error:

*Mar 1 02:20:36.791: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/14

*Mar 1 02:20:36.791: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/14

*Mar 1 02:20:36.800: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/14 has bad crc

We have done shutdown and no shutdown but to no avail. Also we have tested ports with known working SFP’s and still get the same errors.

Any help would be appreciated, Thanks: Here are the error logs:

This is after inserting each GBIC

=================================

SILSSWC-WTTSL2#

*Mar 1 02:20:36.791: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/14

*Mar 1 02:20:36.791: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/14

*Mar 1 02:20:36.800: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/14 has bad crc

SILSSWC-WTTSL2#

*Mar 1 02:20:41.892: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/15

*Mar 1 02:20:41.900: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/15 has bad crc

SILSSWC-WTTSL2#

*Mar 1 02:20:45.490: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/16

*Mar 1 02:20:45.499: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/16 has bad crc

SILSSWC-WTTSL2#

*Mar 1 02:20:49.064: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/17

*Mar 1 02:20:49.072: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/17 has bad crc

SILSSWC-WTTSL2#

*Mar 1 02:20:52.394: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/18

*Mar 1 02:20:52.403: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/18 has bad crc

SILSSWC-WTTSL2#

*Mar 1 02:20:55.221: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/19

*Mar 1 02:20:55.230: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/19 has bad crc

SILSSWC-WTTSL2#

*Mar 1 02:20:58.308: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/20

*Mar 1 02:20:58.317: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/20 has bad crc

SILSSWC-WTTSL2#

*Mar 1 02:21:36.602: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/0/3: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -13.5 dBm.

*Mar 1 02:21:37.550: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/0/6: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -13.5 dBm.

SILSSWC-WTTSL2#

*Mar 1 02:21:38.683: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/0/8: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -13.5 dBm.

*Mar 1 02:21:39.152: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/0/9: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -13.5 dBm.

*Mar 1 02:21:39.614: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/0/10: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -13.5 dBm.

SILSSWC-WTTSL2#

*Mar 1 02:21:40.151: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/0/11: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -13.5 dBm.

*Mar 1 02:21:40.520: %SFF8472-5-THRESHOLD_VIOLATION: Gi1/0/12: Tx power low alarm; Operating value: -40.0 dBm, Threshold value: -13.5 dBm.

SILSSWC-WTTSL2#

Output of ‘show log’ after inserting GBICs in ports 14 through 20.

===================================================================

*Mar 1 02:18:42.379: %SYS-5-CONFIG_I: Configured from console by vty0 (100.0.0.199)

*Mar 1 02:19:11.303: %LINK-5-CHANGED: Interface GigabitEthernet1/0/20, changed state to administratively down

*Mar 1 02:19:18.350: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/20

*Mar 1 02:19:18.358: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/20 has bad crc

*Mar 1 02:19:18.358: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/20, putting Gi1/0/20 in err-disable state

*Mar 1 02:19:19.734: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/20, changed state to down

*Mar 1 02:19:30.161: %SYS-5-CONFIG_I: Configured from console by vty0 (100.0.0.199)

*Mar 1 02:20:36.791: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/14

*Mar 1 02:20:36.791: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/14

*Mar 1 02:20:36.800: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/14 has bad crc

*Mar 1 02:20:41.892: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/15

*Mar 1 02:20:41.900: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/15 has bad crc

*Mar 1 02:20:45.490: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/16

*Mar 1 02:20:45.499: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/16 has bad crc

*Mar 1 02:20:49.064: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/17

*Mar 1 02:20:49.072: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/17 has bad crc

*Mar 1 02:20:52.394: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/18

*Mar 1 02:20:52.403: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/18 has bad crc

*Mar 1 02:20:55.221: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/19

*Mar 1 02:20:55.230: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/19 has bad crc

*Mar 1 02:20:58.308: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/20

*Mar 1 02:20:58.317: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/20 has bad crc

Output of ‘show interface status’

=================================

See each of those ports shows unknown. Also just noticed port Gi1/0/5 showing the same error.

SILSSWC-WTTSL2#sh int status

Port Name Status Vlan Duplex Speed Type

Gi1/0/1 WTTSL2-MCA notconnect 2 auto auto 10/100/1000BaseTX SFP

Gi1/0/2 WTTSL2-MCB notconnect 2 auto auto 10/100/1000BaseTX SFP

Gi1/0/3 WTTSL2-DLA (When F notconnect 2 full 1000 1000BaseSX SFP

Gi1/0/4 WTTSL2-DLB notconnect 2 auto auto 10/100/1000BaseTX SFP

Gi1/0/5 WTTSL2-DP3A notconnect 2 full 1000 unknown

Gi1/0/6 WTTSL2-DP4A (When notconnect 2 full 1000 1000BaseSX SFP

Gi1/0/7 WTTSL2-NAS connected 2 a-full a-1000 10/100/1000BaseTX SFP

Gi1/0/8 notconnect 2 full 1000 1000BaseSX SFP

Gi1/0/9 notconnect 2 full 1000 1000BaseSX SFP

Gi1/0/10 notconnect 2 full 1000 1000BaseSX SFP

Gi1/0/11 notconnect 2 full 1000 1000BaseSX SFP

Gi1/0/12 notconnect 2 full 1000 1000BaseSX SFP

Gi1/0/13 WTTSL2-PSIM notconnect 3 auto auto 10/100/1000BaseTX SFP

Gi1/0/14 WTTSL2-OMNI1-Link1 err-disabled 3 full 1000 unknown

Gi1/0/15 WTTSL2-OMNI2-Link1 err-disabled 3 full 1000 unknown

Gi1/0/16 WTTSL2-TGRSRV err-disabled 3 full 1000 unknown

Gi1/0/17 WTTSL2-TGRCLNT (Wh err-disabled 3 full 1000 unknown

Gi1/0/18 err-disabled 3 full 1000 unknown

Gi1/0/19 err-disabled 3 full 1000 unknown

Gi1/0/20 err-disabled 3 full 1000 unknown

Gi1/0/21 connected 3 full 1000 1000BaseSX SFP

Gi1/0/22 notconnect 3 full 1000 1000BaseSX SFP

Gi1/0/23 notconnect 3 full 1000 1000BaseSX SFP

Gi1/0/24 WTTSL2-TIMESOURCE connected 66 a-full a-100 10/100/1000BaseTX SFP

Fa0 notconnect routed auto auto 10/100BaseTX

SILSSWC-WTTSL2#

Output when all ports are set to shutdown and then no shut.

===========================================================

SILSSWC-WTTSL2(config)#int range gi1/0/14 — 20

SILSSWC-WTTSL2(config-if-range)#shut

SILSSWC-WTTSL2(config-if-range)#

*Mar 1 02:26:39.045: %LINK-5-CHANGED: Interface GigabitEthernet1/0/14, changed state to administratively down

*Mar 1 02:26:39.045: %LINK-5-CHANGED: Interface GigabitEthernet1/0/15, changed state to administratively down

*Mar 1 02:26:39.053: %LINK-5-CHANGED: Interface GigabitEthernet1/0/16, changed state to administratively down

*Mar 1 02:26:39.053: %LINK-5-CHANGED: Interface GigabitEthernet1/0/17, changed state to administratively down

*Mar 1 02:26:39.062: %LINK-5-CHANGED: Interface GigabitEthernet1/0/18, changed state to administratively down

*Mar 1 02:26:39.062: %LINK-5-CHANGED: Interface GigabitEthernet1/0/19, changed state to administratively down

SILSSWC-WTTSL2(config-if-range)#

*Mar 1 02:26:39.070: %LINK-5-CHANGED: Interface GigabitEthernet1/0/20, changed state to administratively down

SILSSWC-WTTSL2(config-if-range)#no shut

SILSSWC-WTTSL2(config-if-range)#

*Mar 1 02:26:52.677: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/17

*Mar 1 02:26:52.685: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/17 has bad crc

*Mar 1 02:26:52.685: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/17, putting Gi1/0/17 in err-disable state

*Mar 1 02:26:52.727: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/15

*Mar 1 02:26:52.735: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/15 has bad crc

*Mar 1 02:26:52.735: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/15, putting Gi1/0/15 in err-disable state

*Mar 1 02:26:52.777: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/14

*Mar 1 02:26:52.777: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/14

*Mar 1 02:26:52.786: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/14 has bad crc

*Mar 1 02:26:52.786: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/14, putting Gi1/0/14 in err-disable state

*Mar 1 02:26:52.819: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/18

*Mar 1 02:26:52.828: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/18 has bad crc

*Mar 1 02:26:52.828: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/18, putting Gi1/0/18 in err-disable state

*Mar 1 02:26:52.861: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/20

*Mar 1 02:26:52.869: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/20 has bad crc

*Mar 1 02:26:52.869: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/20, putting Gi1/0/20 in err-disable state

*Mar 1 02:26:52.903: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/19

*Mar 1 02:26:52.911: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/19 has bad crc

SILSSWC-WTTSL2(config-if-range)#

*Mar 1 02:26:52.911: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/19, putting Gi1/0/19 in err-disable state

*Mar 1 02:26:53.020: %PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP interface Gi1/0/16

*Mar 1 02:26:53.029: %GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi1/0/16 has bad crc

*Mar 1 02:26:53.029: %PM-4-ERR_DISABLE: gbic-invalid error detected on Gi1/0/16, putting Gi1/0/16 in err-disable state

SILSSWC-WTTSL2(config-if-range)#

*Mar 1 02:26:54.010: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/14, changed state to down

*Mar 1 02:26:54.036: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/15, changed state to down

*Mar 1 02:26:54.052: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/16, changed state to down

*Mar 1 02:26:54.069: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/17, changed state to down

*Mar 1 02:26:54.094: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/18, changed state to down

*Mar 1 02:26:54.111: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/19, changed state to down

*Mar 1 02:26:54.128: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/20, changed state to down

SILSSWC-WTTSL2(config-if-range)#

Same again on port 5

====================

SILSSWC-WTTSL2#conf t

Enter configuration commands, one per line. End with CNTL/Z.

SILSSWC-WTTSL2(config)#int gi1/0/5

SILSSWC-WTTSL2(config-if)#shut

*Mar 1 02:28:14.113: %LINK-5-CHANGED: Interface GigabitEthernet1/0/5, changed state to administratively down

SILSSWC-WTTSL2(config-if)#no shut

SILSSWC-WTTSL2(config-if)#

*Mar 1 02:28:24.079: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/5, changed state to down

SILSSWC-WTTSL2(config-if)#^Z

SILSSWC-WTTSL2#dh

*Mar 1 02:28:31.654: %SYS-5-CONFIG_I: Configured from console by vty0 (100.0.0.199)

SILSSWC-WTTSL2#sh log

Syslog logging: enabled (0 messages dropped, 0 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)

No Active Message Discriminator.

I am trying to connect «sfp-1ge-fe-e-t» sfp module to CISCO Catalyst C3560G-48TS switch.

When i pluged module to the port and following error was shown:

%GBIC_SECURITY_CRYPT-4-VN_DATA_CRC_ERROR: GBIC in port Gi0/49 has bad crc

Then I searched solution for the problem, so I found several solution that describes same steps.

like that:
how to connect 3rd party sfp to the cisco switches

I tried following commands:

# service unsupported-transceiver

# no errdisable detect cause sfp-config-mismatch
# no errdisable detect cause gbic-invalid

But it didn’t help actually. I couldn’t turn on GBIC ports. It always shows «status down, protocol down».

Even show idprom interface gigabitEthernet 0/49 command doesn’t show anything.

I have been experiencing with the proplem for two days.

Which steps should i follow? what is the real solution?
Thanks in advance

enter image description here
enter image description here
enter image description here
enter image description here

asked Jul 25, 2018 at 7:52

Simral Abdurahim's user avatar

1

I’m afraid the real solution is to use either Cisco transceivers or third-party transceivers — from reputable vendors- that are specifically «tagged» to be used on Cisco switches.

Using random transceivers will only cause troubles and the time you will loose will vastly overcome the economy made on the hardware.

Edit:

As you can see in this datasheet the C3560G-48TS has SFP (1Gb) ports, not SFP+ (10Gb). So you cannot use a SFP+ transceiver like sfp-10g-sr

You can use this compatibility matrix to check which transceiver are compatible with your switch.

answered Jul 25, 2018 at 8:09

JFL's user avatar

JFLJFL

19k1 gold badge31 silver badges64 bronze badges

3

You SFP has to be Cisco tagged.

Please note that some SFP supplier can provide a programmer to retag SFP on the fly.

We used this a lot, this is very convenient for spare management when you used mixed devices brands/models. Now we have lots of spare for every devices…

We use a specific programmer from a specific SFP vendor, but there is also generic solutions and DIY solutions (search SFP programmer on google)

answered Aug 1, 2018 at 21:03

Golgot's user avatar

GolgotGolgot

4272 silver badges9 bronze badges

try this command :

(note that you should type it and it is not auto complete )

 # no errdisable detect cause gbic-inv service unsupported-transceiver

then remove SFP. then shut/no shut. then put it back.

if it doesn’t work try default the port:

conf t # default int gig1/1/1

if it doesn’t work, you should test all of combination of above command + physical job.

answered Jul 25, 2018 at 12:15

hamid bayat's user avatar

hamid bayathamid bayat

2042 silver badges8 bronze badges

4

Понравилась статья? Поделить с друзьями:

Читайте также:

  • Gbak error requires both input and output filenames
  • Gbak error gds receive failed
  • Gbak error expected backup version 1 9 found 10
  • Gbak error expected backup description record
  • Gb70 noco genesis индикатор ошибки

  • 0 0 голоса
    Рейтинг статьи
    Подписаться
    Уведомить о
    guest

    0 комментариев
    Старые
    Новые Популярные
    Межтекстовые Отзывы
    Посмотреть все комментарии