In template:
Use miiocli device --ip <ip address> --token <token>
.
But it’s gives an error:
Error: Missing command.
Correct comand:
Use miiocli device --ip <ip address> --token <token> info
.
This issue is translated by DeepL from Chinese.
Describe the bug
When I try to control cuco.plug.v3 using this project, the following error is thrown:
pydantic.error_wrappers.ValidationError: 5 validation errors for DeviceModel
services -> 3 -> properties -> 0 -> gatt-access
extra fields not permitted (type=value_error.extra)
services -> 3 -> properties -> 1 -> gatt-access
extra fields not permitted (type=value_error.extra)
services -> 12 -> properties -> 0 -> gatt-access
extra fields not permitted (type=value_error.extra)
services -> 12 -> properties -> 1 -> gatt-access
extra fields not permitted (type=value_error.extra)
services -> 13 -> properties -> 0 -> gatt-access
extra fields not permitted (type=value_error.extra)
I’ve never used pydantic, so I googled and found that this thing seems to include the ability to validate schema, so I tried removing all the gatt-access fields from the cache and after that it was back to normal and I could control my device normally.
Version information (please complete the following information):
- OS: Windows 11 22H2 and Rocky Linux 8.7
- python-miio: 0.6.0.dev0
Device information:
- Model: cuco.plug.v3
- Hardware version: ESP32C3
- Firmware version: 1.0.6
To Reproduce
Steps to reproduce the behavior:
All commands and api that use genericmiot.
Expected behavior
No exception are thrown.
Console output
ERROR:miio.click_common:Exception: 5 validation errors for DeviceModel
services -> 3 -> properties -> 0 -> gatt-access
extra fields not permitted (type=value_error.extra)
services -> 3 -> properties -> 1 -> gatt-access
extra fields not permitted (type=value_error.extra)
services -> 12 -> properties -> 0 -> gatt-access
extra fields not permitted (type=value_error.extra)
services -> 12 -> properties -> 1 -> gatt-access
extra fields not permitted (type=value_error.extra)
services -> 13 -> properties -> 0 -> gatt-access
extra fields not permitted (type=value_error.extra)
Traceback (most recent call last):
File "D:projectsremote-boot.venvLibsite-packagesmiioclick_common.py", line 54, in __call__
return self.main(*args, **kwargs)
^^^^^^^^^^^^^^^^^^^^^^^^^^
File "D:projectsremote-boot.venvLibsite-packagesclickcore.py", line 1055, in main
rv = self.invoke(ctx)
^^^^^^^^^^^^^^^^
File "D:projectsremote-boot.venvLibsite-packagesclickcore.py", line 1657, in invoke
return _process_result(sub_ctx.command.invoke(sub_ctx))
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "D:projectsremote-boot.venvLibsite-packagesclickcore.py", line 1657, in invoke
return _process_result(sub_ctx.command.invoke(sub_ctx))
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "D:projectsremote-boot.venvLibsite-packagesclickcore.py", line 1404, in invoke
return ctx.invoke(self.callback, **ctx.params)
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "D:projectsremote-boot.venvLibsite-packagesclickcore.py", line 760, in invoke
return __callback(*args, **kwargs)
^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "D:projectsremote-boot.venvLibsite-packagesmiioclick_common.py", line 314, in wrap
result_msg = result_msg_fmt(**kwargs)
^^^^^^^^^^^^^^^^^^^^^^^^
File "D:projectsremote-boot.venvLibsite-packagesmiiodevice.py", line 45, in _info_output
dev = DeviceFactory.create(result.ip_address, result.token, force_generic_miot=True)
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "D:projectsremote-boot.venvLibsite-packagesmiiodevicefactory.py", line 101, in create
dev.info()
File "D:projectsremote-boot.venvLibsite-packagesmiioclick_common.py", line 184, in _wrap
self._fetch_info()
File "D:projectsremote-boot.venvLibsite-packagesmiiointegrationsgenericmiotgenericmiot.py", line 344, in _fetch_info
self.initialize_model()
File "D:projectsremote-boot.venvLibsite-packagesmiiointegrationsgenericmiotgenericmiot.py", line 206, in initialize_model
self._miot_model = miotcloud.get_device_model(self.model)
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "D:projectsremote-boot.venvLibsite-packagesmiiomiot_cloud.py", line 66, in get_device_model
return DeviceModel.parse_obj(spec)
^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "pydanticmain.py", line 527, in pydantic.main.BaseModel.parse_obj
File "D:projectsremote-boot.venvLibsite-packagesmiiomiot_models.py", line 436, in __init__
super().__init__(*args, **kwargs)
File "pydanticmain.py", line 342, in pydantic.main.BaseModel.__init__
pydantic.error_wrappers.ValidationError: 5 validation errors for DeviceModel
services -> 3 -> properties -> 0 -> gatt-access
extra fields not permitted (type=value_error.extra)
services -> 3 -> properties -> 1 -> gatt-access
extra fields not permitted (type=value_error.extra)
services -> 12 -> properties -> 0 -> gatt-access
extra fields not permitted (type=value_error.extra)
services -> 12 -> properties -> 1 -> gatt-access
extra fields not permitted (type=value_error.extra)
services -> 13 -> properties -> 0 -> gatt-access
extra fields not permitted (type=value_error.extra)
Is your feature request related to a problem? Please describe.
It is possible to have some type of release schedule for minor updates like bug fixes and new simple devices?
Describe the solution you’d like
A once in month minor release would be nice to have.
But I don’t trying to push you, and life sometimes hits hard, take your time.
Additional context
it’s 5 months from last public release. And there was same type of a problem already #1463
Hi,
I’ve got a couple of Xiaomi G1 vacuums, which I can connect to via the python-miio CLI, but I can’t figure out how to use the API.
Even a basic bit of code from the docs:
from miio import DeviceFactory
dev = DeviceFactory.create("192.168.x.xxx", "my-token-here")
print(f"Status: {dev.status()}")
Returns the following:
Traceback (most recent call last):
File "c:pythontestxiaomitest.py", line 2, in <module>
from miio import DeviceFactory
File "C:UsersUserAppDataRoamingPythonPython311site-packagesmiio__init__.py", line 12, in <module>
from miio.device import Device, DeviceStatus # isort: skip
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "C:UsersUserAppDataRoamingPythonPython311site-packagesmiiodevice.py", line 8, in <module>
import click
ModuleNotFoundError: No module named 'click'
I’ve also had a look at #817, but that seems to be designed for HomeAssistant, so package names/locations don’t match up.
UPDATE:
Actually persevered and can get the model returned with this:
from miio.device import Device
dev = Device("192.168.x.xxx", "my-token-here")
print(f"Status: {dev.model}")
Although that is on linux, Windows seems to still generate the errors above.
So, probably still need help/advice, but will also keep on prodding the code
Thanks,
Richie
It would be useful to allow creating device instances directly from the cloudinfo objects to make the onboarding simpler.
This could be done either by adding a new method to the cloudinfo class, or alternatively allow passing a cloudinfo object to devicefactory.
Spotted in #1717 (comment)
Device information:
- Name(s) of the device: Dreame D10Plus
- Link: https://www.amazon.fr/gp/product/B09TWBQH53
Use miiocli device --ip <ip address> --token <token> info
.
- Model: dreame.vacuum.r2205
- Hardware version: Linux
- Firmware version: 4.1.8_1078
Additional context
-
In full charge and no activity:
miiocli dreamevacuum —ip —token statusWARNING:miio.device:Found an unsupported model ‘dreame.vacuum.r2205’ for class ‘DreameVacuum’. If this is working for you, please open an issue at https://github.com/rytilahti/python-miio/
WARNING:miio.miot_device:Unable to find mapping for dreame.vacuum.r2205, falling back to dreame.vacuum.mc1808
ERROR:miio.integrations.vacuum.dreame.dreamevacuum_miot:Unknown ChargingStats (0)
ERROR:miio.integrations.vacuum.dreame.dreamevacuum_miot:Unknown model for cleaning mode (dreame.vacuum.r2205)
ERROR:miio.integrations.vacuum.dreame.dreamevacuum_miot:Unknown FaultStatus (100)
ERROR:miio.integrations.vacuum.dreame.dreamevacuum_miot:Unknown OperatingMode (None)
Battery level: 13
Brush life level: None
Brush left time: None
Charging state: None
Cleaning mode: None
Device fault: None
Device status: Sweeping
Filter left level: None
Filter life level: None
Life brush main: None
Life brush side: None
Life sieve: None
Map view: None
Operating mode: None
Side cleaning brush left time: None
Side cleaning brush life level: None
Time zone: None
Timer enabled: None
Timer start time: None
Timer stop time: None
Voice package: None
Volume: None
Water flow: None
Water box attached: None
Cleaning time: None
Cleaning area: None
First clean time: None
Total clean time: None
Total clean times: None
Total clean area: None -
At 92% of charge and in cleaning mode:
miiocli dreamevacuum —ip —token statusWARNING:miio.device:Found an unsupported model ‘dreame.vacuum.r2205’ for class ‘DreameVacuum’. If this is working for you, please open an issue at https://github.com/rytilahti/python-miio/
WARNING:miio.miot_device:Unable to find mapping for dreame.vacuum.r2205, falling back to dreame.vacuum.mc1808
ERROR:miio.integrations.vacuum.dreame.dreamevacuum_miot:Unknown ChargingStats (0)
ERROR:miio.integrations.vacuum.dreame.dreamevacuum_miot:Unknown model for cleaning mode (dreame.vacuum.r2205)
ERROR:miio.integrations.vacuum.dreame.dreamevacuum_miot:Unknown FaultStatus (92)
ERROR:miio.integrations.vacuum.dreame.dreamevacuum_miot:Unknown OperatingMode (None)
Battery level: 1
Brush life level: None
Brush left time: None
Charging state: None
Cleaning mode: None
Device fault: None
Device status: Idle
Filter left level: None
Filter life level: None
Life brush main: None
Life brush side: None
Life sieve: None
Map view: None
Operating mode: None
Side cleaning brush left time: None
Side cleaning brush life level: None
Time zone: None
Timer enabled: None
Timer start time: None
Timer stop time: None
Voice package: None
Volume: None
Water flow: None
Water box attached: None
Cleaning time: None
Cleaning area: None
First clean time: None
Total clean time: None
Total clean times: None
Total clean area: None
Device information:
- Name(s) of the device: Xiaomi WalkingPad A1 Pro
- Link:
Use miiocli device --ip <ip address> --token <token>
.
- Model: ksmb.walkingpad.v1
- Hardware version: MTK7697
- Firmware version: 2.0.5
Additional context
Expose DeviceInfoUnavailableException
directly through miio
module, and check also that other exceptions are exposed properly.
Model: yeelink.light.colorb
Hardware version: esp8266
Firmware version: 2.0.8_0010
All features work correctly
Hi guys, I’m new at this smart home world.
I would like to know how can I update my home assistant to use the git master from this repo instead of the last version 0.5.12?
Currently I’m getting on Home Assistant:
2023-02-01 01:32:52.825 WARNING (SyncWorker_1) [miio.device] Found an unsupported model 'dreame.vacuum.mc1808' for class 'RoborockVacuum'. If this is working for you, please open an issue at https://github.com/rytilahti/python-miio/
2023-02-01 01:33:08.875 ERROR (SyncWorker_1) [miio.miioprotocol] Got error when receiving: {'code': -9999, 'message': 'user ack timeout'}
I saw this issue which seems like the same problem.
I’m using this HA integration and I don’t know how can I update to master branch and see if it works.
Found an unsupported model ‘roborock.vacuum.a01’ for class ‘RoborockVacuum’. If this is working for you, please open an issue.
This is the Roborock E4. Not sure if there’s any other information you’d like.
Device information:
-
Name(s) of the device: Xiaomi Smart Air Purifier 4
-
Model: zhimi.airp.mp4
-
Hardware version: esp32
-
Firmware version: 2.2.1
Could not be used due to error:
Found an unsupported model ‘zhimi.airp.mp4’ for class ‘AirPurifierMiot’
Accessing choices_attribute
of the enumsettingdescriptor may cause an exception.
DEBUG:miio.miioprotocol:192.168x.x:54321 >>: {'id': 207, 'method': 'get_multi_maps_list', 'params': []}
DEBUG:miio.miioprotocol:192.168x.x:54321 (ts: 2023-01-30 13:09:12, id: 207) << {'id': 207, 'result': 'unknown_method'}
Traceback (most recent call last):
File "<stdin>", line 1, in <module>
File "/home/tpr/code/python-miio/miio/device.py", line 349, in sensors
self._initialize_descriptors()
File "/home/tpr/code/python-miio/miio/device.py", line 236, in _initialize_descriptors
self._settings = self._setting_descriptors_from_status(status)
File "/home/tpr/code/python-miio/miio/device.py", line 201, in _setting_descriptors_from_status
setting.choices = retrieve_choices_function()
File "/home/tpr/code/python-miio/miio/integrations/roborock/vacuum/vacuum.py", line 388, in _map_enum
maps = self.get_maps()
File "/home/tpr/code/python-miio/miio/click_common.py", line 185, in _wrap
return func(self, *args, **kwargs)
File "/home/tpr/code/python-miio/miio/integrations/roborock/vacuum/vacuum.py", line 380, in get_maps
self._maps = MapList(self.send("get_multi_maps_list")[0])
File "/home/tpr/code/python-miio/miio/integrations/roborock/vacuum/vacuumcontainers.py", line 112, in __init__
for map in self.data["map_info"]:
TypeError: string indices must be integers
Originally posted by @rytilahti in #1701 (comment)
Before submitting a new request, use the search to see if there is an existing issue for the device.
Device information:
- Name(s) of the device: Mi Smart LED Ceiling Light 350mm
- Link:
Use miiocli device --ip <ip address> --token <token> info
.
- Model: yeelink.light.ceil34
- Hardware version: esp32
- Firmware version: 2.1.7_0023
Additional context
If you know already about potential commands or any other useful information to add support for the device, please add that information here.
what must be done to reactivate this device?
#832
Write-only settings generate also setting descriptors with property names.
This is confusing as the property is not really available in the status container, causing KeyError on access.
Potential solutions:
- Add access information to the settings descriptor
- Set property to None and leave it for downstreams to check for that
This meta task will track the progress and tasks to do for the next major release, which aims to simplify the use of the library for downstream users and reorganize the organically grown code base to be more maintainable.
This issue will give an overview of the planned changes, which are discussed more in-depth under their corresponding issues linked below as they get written. This meta issue shall serve as a checklist for the changelog, and is open for discussions.
Repository structure
- Motivation: all source files are currently stored in the main miio directory for historical reasons, making it messy.
- Goal: by splitting each individual implementation (integration?) and files related to it (e.g., tests and some data files) will clean up the code base.
Tasks
- Separate integrations and their tests to their own directories under
miio/integrations/<name>
ormiio/integrations/<type of device>/<name>
. #1115 - #1696
«Device factory»
- Motivation: there is currently no way to construct device instances just by knowing their host and the token, making it necessary for downstreams to import the classes implementing the support and initializing it separately based on model information (or simply supporting a single implementation, like done by homeassistant’s vacuum platform).
- Goal: allow initializing device-derived objects by simply knowing their host and the token which simplifies downstream implementations.
Tasks
- Add manifest files to integrations that describe supported models (miIO.info-based and mDNS entries) #1116
- Add facilities to access information about supported devices, and initialize implementations by using only the host and the token #1117
Common APIs
- Motivation: adding support for devices of the same device class (e.g., vacuums) is cumbersome as there is no well-defined API among the different implementations.
- Goal: provide device-type based base classes to make adding support for new device integrations on downstream just a matter of upgrading the python-miio.
Tasks
- Create base classes for individual device types where it makes sense to make it easier for downstreams to add support for a class of devices.
- Need replaced partially with introspectable interfaces: #1495
- Add model detection based on
miIO.info
to consolidate handling of device-specific differences inside a single integration. #1038 - Add
supported_features
or similar feature flags to allow integrations specify which features is supported by the device model. This will allow moving these checks from downstream (homeassistant most prominently) to where this information belongs.- Need replaced partially with introspectable interfaces: #1495
- Make available sensors introspectable (status class properties could be extended to allow defining metadata for available sensors). #1495
- Make available actions introspectable by exposing
@command
s.
MiOT support
- Motivation: all new devices are using miot instead of custom protocols to control devices, so it makes sense to add first class support to the library.
- Goal: all miot supporting devices can be controlled as long as internet-connectivity is available to fetch the required schema file.
Tasks
- Create generic miot integration #1581
- Provide consolidated information (including descriptions, icons, etc.) for standard settings and actions using a yaml metadata file: #1618
- Add support for actions with multiple input parameters (exposed as custom services in homeassistant?): #1663
- Add support for write-only properties (exposed as custom services in homeassistant?): #1662
- Clean up and deprecate old miot integrations that do not provide extra functionality compared to the generic interface
Other changes
- Clean-up constructors to use an «options» container instead of relying on separate kwarg arguments for special cases. #1156
- #1683
- Consolidate out-of-range input values to raise standard exceptions (e.g.,
ValueError
instead of custom exception types) #1558 - Modify miiocli to save the «options» object much like mirobo does for sequence ids. This would fix the long-standing problems some users are having caused by the id reuse.
Move each integration to their own directory, containing the integration-specific implementation, data and test files.
This allows separate integrations to have their own data files stored without poluting the main package (see, e.g., #1094 for yeelight spec files), and make the integrations partially self-contained.
This also allows adding integration-specific, discoverable manifest files whose pros are discussed in another issue to be linked here.
Each integration should be stored under miio/integrations/<name>
which can contain several source files including unit tests and any other data.
Status
- Yeelight (#1160)
Ошибка ERR_CONNECTION_TIMED_OUT появляется, когда вы открываете какой-то сайт или страницу в социальной сети. Это может произойти на любом веб-сервере, независимо от его популярности, качества и наличия обновлений.
Что это за ошибка ERR_CONNECTION_TIMED_OUT
Когда открывается сайт, ваш ПК обращается к серверу, чтобы отобразить содержимое. На это отводится определенное время, когда оно заканчивается, вам сообщают, что страница недоступна, т.к., время соединения истекло – описание ошибки именно так звучит в переводе.
Ошибка Err connection timed out
Фактически, это означает, что возникли какие-то проблемы на сайте или конкретно с вашим подключением. Причем, ошибка касается только одного ресурса, например, Facebook, а с другими всё в порядке, можно спокойно просмотреть содержимое.
Ошибка может быть вызвана:
- большим количеством одновременных обращений к серверу (чаще всего в играх, а также в определенные периоды, например, в Новогоднюю ночь, когда все поздравляют друг друга в социальных сетях и совершают много одинаковых действий в одно и то же время);
- сбоем маршрутизатора;
- блокировкой антивируса.
Как исправить ошибку ERR_CONNECTION_TIMED_OUT
Есть несколько способов справиться с возникшей проблемой, если только это не связано с самим сайтом. В противном случае лучше написать в службу поддержки.
Сброс интернет-соединения
При появлении CONNECTION_TIMED_OUT_CONNECT первое, что нужно сделать – выключить роутер и оставить его на 1-2 минуты, а затем снова включить. После перезагрузки ситуация может исправиться.
Обновление IP и сброс Winsock
Если первый метод не помог, попробуем менее очевидный:
- В «Пуске» найдите Command Line, кликните дополнительной кнопкой мыши и выберите Run As Administrator.
- В поле впишите ipconfig /release + «Enter».
- Не дожидаясь сообщения о ходе операции, наберите также: ipconfig /all + «Enter».
- Затем впишите: ipconfig /flushdns + «Enter».
- Снова не ждите отчета системы, вбивайте: ipconfig /renew + «Enter» и netsh int ip set dns + «Enter» (сохраняйте все знаки и пробелы).
- И, наконец, последняя команда, позволяющая сбросить предустановки Windows Sockets: netsh winsock reset + «Enter».
Перезапустите систему и попробуйте зайти на проблемный сайт, чтобы убедиться, что ошибка исправлена.
Переход на публичные DNS-серверы
Публичные DNS сервера
В этом случае мы воспользуемся серверами, которые предлагает Google:
- Кликните дополнительной кнопкой манипулятора по «Пуску» и нажмите Network connection.
- Найдите название существующего, щелкните по нему дважды и выберите вкладку Properties.
- Здесь нужно развернуть ссылку, подписанную Internet Protocol version 4 и отметить, что вы самостоятельно впишите сервер.
- Вы увидите две строчки: в первую впишите 8.8.8.8., а во вторую — 8.8.4.4.
- Согласитесь с изменениями и перезагрузите ПК.
- Попробуйте открыть сайт.
Если ничто не помогло, обязательно проверьте, не фильтрует ли антивирус сайт, на который вы безуспешно пытаетесь попасть. Откройте настройки брандмауэра и создайте правило для сайта, в котором будет прописано разрешение на установление соединения.
Также блокировать сайт может встроенный брандмауэр Windows. Его можно отключить, если у вас есть антивирус или вписать адрес ресурса в список исключений.
Просмотров 41.8к. Опубликовано 20 мая, 2019 Обновлено 24 июня, 2019
ERR_CONNECTION_TIMED_OUT довольно распространена в Windows, Android и Mac. Это ошибка браузера, которая указывает, что что-то не так с веб-сайтом, который вы пытаетесь открыть, или с тем, какой путь вы используете для его достижения. Ошибка не говорит о том, что она, скорее всего, вызвана неправильной настройкой на вашем компьютере, а не в сети.
Что касается браузера, путь к Интернету начинается с вашей сетевой карты. Любые проблемы с этого момента — это «соединение», поскольку это связано с синтаксисом ошибок.
Как правило, есть три вещи, которые вы можете сделать, чтобы исправить ошибки ERR_CONNECTION_TIMED_OUT в Windows. Проверьте конфигурацию сети, проверьте файл HOSTS и обновите свой стек DNS и IP. Хотя каждый из них может показаться сложным, на самом деле это довольно просто сделать.
В этом руководстве предполагается, что ваш интернет работает для всего остального, но в вашем браузере обнаружены ошибки ERR_CONNECTION_TIMED_OUT.
Проверьте конфигурацию сети
Ошибки конфигурации сети обычно возникают сразу после обновления сетевого драйвера или значительного обновления Windows.
- На клавиатуре нажать комбинацию клавиш Win+R.
- В открывшемся окне, в поле «Открыть», напечатать или скопировать туда с этой страницы команду «ncpa.cpl«. Нажать клавишу Enter.
- Выберите вашу сетевую карту, щелкните правой кнопкой мыши и выберите Свойства.
- Убедитесь, что у IPv4 есть флажок рядом с ним. Некоторые обновления Windows 10 по какой-то причине отключили IPv4. Это может использовать ошибку.
- Выделите IPv4 и выберите Свойства.
- Убедитесь, что выбран параметр «Получить IP-адрес автоматически», если в вашей сети не настроены статические адреса.
- Если выбрано «Получить IP-адрес автоматически», вернитесь на шаг назад и снимите флажок рядом с IPv4.
- Перезагрузите компьютер, повторите шаги 1-3 и еще раз проверьте поле IPv4, чтобы снова включить его.
- Протестируйте.
Проверьте файл WINDOWS HOSTS
В файле Windows HOSTS происходит блокировка веб-сайта. Этот файл может быть изменен вручную или автоматически программами безопасности, поэтому стоит проверить, есть ли у вас проблемы с подключением к веб-сайту.
- Перейдите в C:WindowsSystem32driversetc.
- Щелкните правой кнопкой мыши файл HOSTS и выберите «Изменить».
- Проверьте, указаны ли какие-либо веб-сайты в списке или есть какие-либо ошибки в файле. В стандартном файле HOSTS каждая строка должна иметь знак «#». Это означает, что это только для информации и не активно. Моя картинка на картинке выше была изменена, так как я использую свой файл HOSTS для блокировки рекламы вместо использования блокировщика рекламы.
- Если вы удалили какие-либо строки, перезагрузите компьютер и повторите тестирование.
ОБНОВИТЕ СВОЙ СТЕК DNS И IP, ЧТОБЫ ИСПРАВИТЬ ОШИБКИ ERR_CONNECTION_TIMED_OUT
Проблемы с DNS могут вызвать тайм-ауты, поэтому стоит попробовать, если у вас все еще есть проблемы.
- Откройте командную строку от имени администратора.
- Введите «ipconfig /flushdns».
- Введите «ipconfig /registerdns».
- Введите «ipconfig /release».
- Введите «ipconfig /renew».
- Перезагрузите компьютер и повторите попытку.
Наконец, если ни один из этих шагов не исправляет ошибки ERR_CONNECTION_TIMED_OUT, единственный вариант — удалить браузер и заново установить его. В то время как задача последней инстанции, было известно, чтобы сбросить все и заставить ваш интернет работать как надо. Как вы уже пробовали все остальное, это стоит попробовать!