|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Copyright © 2004-2023 Прокофе.ру |
User manual
3.5.2
LAMP DISPLAY
<< Standby >>
UK
Welcome
Rinse
Heating
Ready
Cash
Espresso
Coffee
Cappuccino
Pot
Hot water
Flashes
Water tank
Page 36
SIGNIFICANCE
The machine is in standby
mode; it is now consuming very
little energy.
Welcome on switching on.
An automatic rinse takes place
when switching on, or the rinsing
programme is active.
The machine is being heated up;
the necessary operating tem-
perature has not yet been
reached
The machine is ready for use.
The green lamp indicates the
optimal operating temperature.
The machine is now ready for
operation and the payment sys-
tem is activated. The green lamp
indicates the optimal operating
temperature.
Drawing of espresso after press-
ing the relevant product button.
Drawing of coffee after pressing
the relevant product button.
Drawing of cappuccino after
pressing the relevant product
button.
Drawing of a pot of coffee after
pressing the product button.
Drawing of hot water.
Flashes:
The water tank is empty or not
correctly inserted.
Illuminated:
Air in the water system
(See chapter
7 Problems and
possible
causes, Page 50).
LAMP DISPLAY
Flashes
No beans
Grinder lid
Grinder block.
Container full
Flashes
Container
Flashes
Hatch open
Cleaning
Flashes
Descaling
Service !!!
SIGNIFICANCE
The beans container is empty.
Further drawing only possible af-
ter filling it.
The lid to the beans container is
not closed correctly.
The grinder is blocked. For
clearance see Operating Instruc-
tions, section.
5.4, Cleaning the
grinder
Page 41.
The grounds container is full.
Further drawing only possible af-
ter emptying it.
The grounds container is not
correctly inserted.
The side door is open. Drawing
only possible after closing it.
The machine must be cleaned,
or the cleaning programme is
active.
The machine must be descaled,
or the descaling programme is
active.
The display alternates with the
current display. Report the ma-
chine to customer service.
(See paragraph
8.1 Service re-
quest
Page 50)
BASL — 02 — V01
Работаем ежедневно c 09:00 до 20:00
без выходных и праздничных дней
8 (495) 135-00-03
Звоните ежедневно с 9:00 до 21:00
м. Кутузовская. ул. Студенческая, д. 35
Кофемашина Schaerer Siena 2 может выдавать ошибку по причине каких-либо неполадок в работе устройства или из-за дефектов элементов. Уточнить, какая именно неисправность постигла вас вы можете в нашем сервисном центре, где работают специалисты высокого уровня с многолетним опытом за плечами. Для связи с нами достаточно заполнить простую форму или позвонить по номерам горячей линии, указанных на сайте. Наши операторы дадут исчерпывающую информацию по интересующим вас вопросам и проконсультирую по ценам на услуги.
Частые неисправности
- Не работает
Проблема может быть в:
— Пустом резервуаре для воды;
— Отсутствии кофе. - Шумит при работе
Причиной проблемы ,может быть:
— Засорение кофемашины;
— Проблемы с насосом. - Нет пара
Проблема может быть связанна с:
— Неисправностью бойлера;
— Неисправностью пароблока;
— Засорение кальцием. - Не мелет кофе
Неисправность связанна с:
— Затупленностью жерновов;
— Неисправностью кофемолки;
— Неисправностью электродвижка кофемолки. - Не наливает воду
Данная проблема, может быть вызвана:
— Требуется чистка вашей кофемашины;
— Проблемы с насосом;
— Замена уплотнительных колец;
— Замена датчиков. - Не наливает кофе
Неисправность могла быть вызвана данными неполадками:
— Засорение кофемашины кофейными маслами (декофинация);
— Обслуживание гидросистемы;
— Чистка диспенсеров. - Не подает пену
Для решения данной проблемы нужно будет:
— Произвести замену капучинатора;
— Провести чистку вашей кофемашины;
— Заменить фильтры;
— Произвести замену жерновов. - Протекает
Проблема может быть в:
— поврежденном уплотнении резервуара воды;
— уплотнительных прокладках;
— уплотнении дозатора;
— неплотной посадки соединительных трубок.
Чаще необходимо
- Диагностика — 0 ₽
- Декальценация — 590 ₽
- Замена ТЭНа — 750 ₽
- Ремонт капучинатора — 850 ₽
- Замена жерновов — 750 ₽
- Ремонт кофемолки — 790 ₽
- Ремонт гидросистемы — 990 ₽
- Ремонт насоса — 700 ₽
Шаги вашего ремонта
-
1
Заявка
Оставляете заявку у нас на сайте или посредством телефонного звонка
-
2
Доставка
Осуществляем забор курьером или доставляете кофемашину к нам в СЦ
-
3
Диагностика
Инженер проводит полную диагностику кофейной машины
-
4
Ремонт
После согласования, производим ремонт кофемашины
-
5
Сообщение
Сообщаем о готовности ремонта и выдаём гарантию до 1 года
инструкцияSchaerer Siena 2
Betriebsanleitung ……………………………………… Seite 2
Operating instructions …………………………. Page 35
Manuel d’utilisation ………………………………… Page 69
Gebruiksaanwijzing ……………………………. Pagina 103
Manual de instrucciones ………………… Página 137
Návod k provozu ………………………………….. Strana 171
Használati utasítás ………………………………. Oldalt 205
V07 / 06.2010
Посмотреть инструкция для Schaerer Siena 2 бесплатно. Руководство относится к категории Кофеварки, 2 человек(а) дали ему среднюю оценку 7.3. Руководство доступно на следующих языках: английский. У вас есть вопрос о Schaerer Siena 2 или вам нужна помощь? Задайте свой вопрос здесь
Главная
Не можете найти ответ на свой вопрос в руководстве? Вы можете найти ответ на свой вопрос ниже, в разделе часто задаваемых вопросов о Schaerer Siena 2.
Как часто следует очищать кофеварку от накипи?
Какой лучший способ очистки кофеварки от накипи?
Как долго можно хранить кофе в зернах?
Как лучше всего хранить кофе?
Как помол сказывается на вкусе кофе?
Инструкция Schaerer Siena 2 доступно в русский?
Не нашли свой вопрос? Задайте свой вопрос здесь
проблема с кофеваркой Schaerer Siena 2 / Абакан
Я запустил очистку кофейной и молочной системы. Всё промылось и машинка была выключена. На следующий день включая машину горела ошибка NTC-Steam. Я проверил хорошо ли закрыты дверцы, вытащил узел пропаривания и задвинул обратно, ничего не изменилось.
Люди с такой же проблемой (0)
Лучшее решение
Просто так совпало. вышел из строя температурный датчик парового бойлера. — замена бойлера
Это решение полезно? Да Нет
2 участника считают, что это решение полезно
Знаете, как решить эту проблему?
Поделитесь своим знанием!
Ваш способ решения:
Наиболее похожие проблемы из этого раздела
Купил, включил, согласно инструкции промыл фильтр, бачок, залил воды чуть ниже максимума, дождался зелёного индикатора, нажал на кнопку насоса — и …
Здравствуйте! Кофемашина Philips 5000 series, при приготовлении капучино сбоку валит пар, молоко пару капель выдаёт, шипит. Что это может быть? И …
Выдаёт ошибку Е5 — ошибка водяного контура… Переустановка бака для воды не помогает. В чём может быть причина, и сколько примерно будет стоить её …
Ошибка E05. Как убрать ошибку и промыть? Вероятно, забился капучинатор.
Кофемашина не включает помол и выдаёт ошибку с-1
-
Leo_1943
- Мастер
- Сообщения: 874
- Зарегистрирован: 03 май 2014, 07:24
- Репутация: 249
- Настоящее имя: Леонид
- Откуда: Харьков
Re: Sinumerik 828D Проблемма с магазином
Сообщение
Leo_1943 » 12 дек 2014, 18:49
Ошибки с номера 7000.., ошибки не системы, а прописаные спецом который автоматику писал и искать нужно только в редакторе PLC, я могу в понедельник глянуть. Там вплоть до отсутствия давления воздуха и ли что то не в исходном. Можно только пин найти на плате РР72/48, а дальше уже Вам по проводам искать.
-
Leo_1943
- Мастер
- Сообщения: 874
- Зарегистрирован: 03 май 2014, 07:24
- Репутация: 249
- Настоящее имя: Леонид
- Откуда: Харьков
Re: Sinumerik 828D Проблемма с магазином
Сообщение
Leo_1943 » 12 дек 2014, 18:51
Кстати мне не архив нужен, а именно файл автоматики, хоть фото с экрана . Его же можно и туда вывести. Хотя текст ошибки гласит» выведите в ноль магазин» даже у некоторых токарнофрезерных станков, перед работой, не только оси, но и револьверная головка выводится в ноль- на первую позицию. Ищите кнопку на пульте. Или я в понедельник может что подскажу.
-
Rasul
- Опытный
- Сообщения: 111
- Зарегистрирован: 24 май 2013, 10:25
- Репутация: 1
- Откуда: Казахстан, Петропавловск
- Контактная информация:
Re: Sinumerik 828D Проблемма с магазином
Сообщение
Rasul » 12 дек 2014, 19:16
Leo_1943 писал(а):Кстати мне не архив нужен, а именно файл автоматики, хоть фото с экрана . Его же можно и туда вывести. Хотя текст ошибки гласит» выведите в ноль магазин» даже у некоторых токарнофрезерных станков, перед работой, не только оси, но и револьверная головка выводится в ноль- на первую позицию. Ищите кнопку на пульте. Или я в понедельник может что подскажу.
Где мне найти файл автоматики и как он выглядит?
Возможно это он? https://cloud.mail.ru/public/3667bd44d7 … 030B05.Alm
- Ни одна кнопкане реагирует
Трудиться — Удел Бога! Халява — Удел Крысы!
-
Leo_1943
- Мастер
- Сообщения: 874
- Зарегистрирован: 03 май 2014, 07:24
- Репутация: 249
- Настоящее имя: Леонид
- Откуда: Харьков
Re: Sinumerik 828D Проблемма с магазином
Сообщение
Leo_1943 » 12 дек 2014, 19:29
До обнуления координат и не должна, а еще должен быть ключ. После включения проверьте аварийные цепи, аварийный стоп, все ли автоматы в шкафу включены, не засорен ли фильтр и т.п. если все нормально то перед включением приводов нужно нажать кнопку reset у Вас на фото левый нижний угол, на ней не зря подсветка светится. А затем выход в ноль осей и магазина инструментов. И поисчите ключ, а то и связка, бывает без них ничего не работает. У каждого ключа свой цвет и уровень допуска, и угол поворота. Если ни одного нет, может вообще не работать. Раньше в 802 пароли были.
-
Rasul
- Опытный
- Сообщения: 111
- Зарегистрирован: 24 май 2013, 10:25
- Репутация: 1
- Откуда: Казахстан, Петропавловск
- Контактная информация:
Re: Sinumerik 828D Проблемма с магазином
Сообщение
Rasul » 12 дек 2014, 19:42
Станок не требует обнуления координат, на всех осях горит значек референтной позиции, все автоматы проверял, «перед включением приводов»- что Вы имеете ввиду ? Обороты и подача?
Есть три ключа, черный, зеленый и оранжевый, на пульте замок на четыре позиции:0,1,2,3. черный 0-1, зеленый 0-1-2, оранжевый, 0-1-2-3, я влючил оранжевым ключем позицию №3 могу изменять все.
Трудиться — Удел Бога! Халява — Удел Крысы!
-
aftaev
- Зачётный участник
- Сообщения: 34009
- Зарегистрирован: 04 апр 2010, 19:22
- Репутация: 6177
- Откуда: Казахстан.
- Контактная информация:
Re: Sinumerik 828D Проблемма с магазином
Сообщение
aftaev » 12 дек 2014, 19:43
Rasul, если не секрет по чем станок брали?
Дилетанту сложные вещи кажутся очень простыми, и только профессионал понимает насколько сложна самая простая вещь
Кто хочет — ищет возможности, кто не хочет — ищет оправдание.
Найди работу по душе и тебе не придется работать.
-
Rasul
- Опытный
- Сообщения: 111
- Зарегистрирован: 24 май 2013, 10:25
- Репутация: 1
- Откуда: Казахстан, Петропавловск
- Контактная информация:
Re: Sinumerik 828D Проблемма с магазином
Сообщение
Rasul » 12 дек 2014, 19:46
Не секрет просто не знаю, в понидельник попытаюсь спросить у директора если он будет на месте))))))
Знаю что брали на заводе изготовителя, должны были приехать наладчики, но китайци наплевали и не приехали…
Трудиться — Удел Бога! Халява — Удел Крысы!
-
Leo_1943
- Мастер
- Сообщения: 874
- Зарегистрирован: 03 май 2014, 07:24
- Репутация: 249
- Настоящее имя: Леонид
- Откуда: Харьков
Re: Sinumerik 828D Проблемма с магазином
Сообщение
Leo_1943 » 12 дек 2014, 19:52
Rasul писал(а):Станок не требует обнуления координат, на всех осях горит значек референтной позиции, все автоматы проверял, «перед включением приводов»- что Вы имеете ввиду ? Обороты и подача?
Есть три ключа, черный, зеленый и оранжевый, на пульте замок на четыре позиции:0,1,2,3. черный 0-1, зеленый 0-1-2, оранжевый, 0-1-2-3, я влючил оранжевым ключем позицию №3 могу изменять все.
Про координаты не настаиваю, вы видимо не пробовали, но без них не обнулится магазин, а у Вас в нем ошибку дает. А точнее магазин не выведен в референтную точку. Без ключа на третьей позиции может не дать залить программу и обнулить
-
Rasul
- Опытный
- Сообщения: 111
- Зарегистрирован: 24 май 2013, 10:25
- Репутация: 1
- Откуда: Казахстан, Петропавловск
- Контактная информация:
Re: Sinumerik 828D Проблемма с магазином
Сообщение
Rasul » 12 дек 2014, 19:57
Leo_1943 писал(а):Про координаты не настаиваю, вы видимо не пробовали, но без них не обнулится магазин, а у Вас в нем ошибку дает. А точнее магазин не выведен в референтную точку. Без ключа на третьей позиции может не дать залить программу и обнулить
Я совсем запутался))) Ключь я поставил на позицию №3, мне что нужно сначало координаты каким то образом обнулить, а потом уже за магазин братьс?
Трудиться — Удел Бога! Халява — Удел Крысы!
-
Leo_1943
- Мастер
- Сообщения: 874
- Зарегистрирован: 03 май 2014, 07:24
- Репутация: 249
- Настоящее имя: Леонид
- Откуда: Харьков
Re: Sinumerik 828D Проблемма с магазином
Сообщение
Leo_1943 » 12 дек 2014, 20:02
Да, стойка может и не просить. Изначально, обнуление координат кнопка ref и плюс (или минус)передвижения по координате для выхода осей в ноль. Затем обнуление магазина, или кнопка на пульте, а бывает вашпе отдельно. Сейчас с мобильного общаюсь не разобрать кнопок и подписей
.
-
Rasul
- Опытный
- Сообщения: 111
- Зарегистрирован: 24 май 2013, 10:25
- Репутация: 1
- Откуда: Казахстан, Петропавловск
- Контактная информация:
Re: Sinumerik 828D Проблемма с магазином
Сообщение
Rasul » 12 дек 2014, 20:11
Leo_1943, Включаю станок кнопка Ref уже горит, на экране возле каждой оси стоит значек «референтная позиция» вот…
А мне нужно обязательно сдвинуть каждую ось(немножко) что бы она обнулилась? Я Васправильно понимаю?
Если Вам не сложно опешите пожалуйсто по порядку список действий, в понидельник я попробую.
Последний раз редактировалось Rasul 12 дек 2014, 20:14, всего редактировалось 1 раз.
Трудиться — Удел Бога! Халява — Удел Крысы!
-
Leo_1943
- Мастер
- Сообщения: 874
- Зарегистрирован: 03 май 2014, 07:24
- Репутация: 249
- Настоящее имя: Леонид
- Откуда: Харьков
Re: Sinumerik 828D Проблемма с магазином
Сообщение
Leo_1943 » 12 дек 2014, 20:13
Да, скорее всего в плюс, обычно. Должна еще быть кнопка включения приводов, без нажатия ее никуда не поедет. И значек может показывать нахождение оси на реф.кулачке но выходтв ноль осей до выхода в ноль магазина обязателен.
-
Rasul
- Опытный
- Сообщения: 111
- Зарегистрирован: 24 май 2013, 10:25
- Репутация: 1
- Откуда: Казахстан, Петропавловск
- Контактная информация:
Re: Sinumerik 828D Проблемма с магазином
Сообщение
Rasul » 12 дек 2014, 20:21
Leo_1943 писал(а):кнопка включения приводов
Есть такие кнопки, для шпинделя ВклВык, для приводов ВклВыкл, если Выкл то горит сообщение «шпиндель стоп» «подача стоп» Вы это имеете ввиду?
Трудиться — Удел Бога! Халява — Удел Крысы!
-
aftaev
- Зачётный участник
- Сообщения: 34009
- Зарегистрирован: 04 апр 2010, 19:22
- Репутация: 6177
- Откуда: Казахстан.
- Контактная информация:
Re: Sinumerik 828D Проблемма с магазином
Сообщение
aftaev » 12 дек 2014, 20:23
Rasul, у тебя стойка на русском?
Дилетанту сложные вещи кажутся очень простыми, и только профессионал понимает насколько сложна самая простая вещь
Кто хочет — ищет возможности, кто не хочет — ищет оправдание.
Найди работу по душе и тебе не придется работать.
-
Rasul
- Опытный
- Сообщения: 111
- Зарегистрирован: 24 май 2013, 10:25
- Репутация: 1
- Откуда: Казахстан, Петропавловск
- Контактная информация:
Re: Sinumerik 828D Проблемма с магазином
Сообщение
Rasul » 12 дек 2014, 20:43
aftaev, Русского языка нет, есть много других языков, а могучего к сожалению нет.
Трудиться — Удел Бога! Халява — Удел Крысы!
-
Rasul
- Опытный
- Сообщения: 111
- Зарегистрирован: 24 май 2013, 10:25
- Репутация: 1
- Откуда: Казахстан, Петропавловск
- Контактная информация:
Re: Sinumerik 828D Проблемма с магазином
Сообщение
Rasul » 15 дек 2014, 07:33
Leo_1943 писал(а):Ошибки с номера 7000.., ошибки не системы, а прописаные спецом который автоматику писал и искать нужно только в редакторе PLC, я могу в понедельник глянуть. Там вплоть до отсутствия давления воздуха и ли что то не в исходном. Можно только пин найти на плате РР72/48, а дальше уже Вам по проводам искать.
Если не сложно, Вы можете сегодня посмотреть?
Трудиться — Удел Бога! Халява — Удел Крысы!
-
Leo_1943
- Мастер
- Сообщения: 874
- Зарегистрирован: 03 май 2014, 07:24
- Репутация: 249
- Настоящее имя: Леонид
- Откуда: Харьков
-
Rasul
- Опытный
- Сообщения: 111
- Зарегистрирован: 24 май 2013, 10:25
- Репутация: 1
- Откуда: Казахстан, Петропавловск
- Контактная информация:
Re: Sinumerik 828D Проблемма с магазином
Сообщение
Rasul » 15 дек 2014, 09:34
Вот еще мысль:
Возможно во время аварии сбилось положение шпинделя.
- Нет такого же значка, как на осях. И угол больше нуля
- На этом окне, тоже показывает,что со шпинделем что то не в порядке.
Возможно есть максимальные отклонения на угол поворота шпинделя, или вообще должны быть равны нулю.
Визуально он стоит в нужном положении (подгоняю к магазину он поподает в паз)
Если ошибаюсь поправьте!
Трудиться — Удел Бога! Халява — Удел Крысы!
-
Leo_1943
- Мастер
- Сообщения: 874
- Зарегистрирован: 03 май 2014, 07:24
- Репутация: 249
- Настоящее имя: Леонид
- Откуда: Харьков
Re: Sinumerik 828D Проблемма с магазином
Сообщение
Leo_1943 » 15 дек 2014, 09:42
Rasul писал(а):Вот еще мысль:
Возможно во время аварии сбилось положение шпинделя.
Вам же пишет, магазин нуждается в реферировании (поиске начала)
-
Contents
-
Table of Contents
-
Bookmarks
Quick Links
SINUMERIK
SINUMERIK 808D ADVANCED
Diagnostics Manual
Diagnostics Manual
06/2015
6FC5398-6DP10-0BA2
Preface
Fundamental safety
instructions
Introduction
Operating in the system data
management operating area
Operating in the alarm
operating area
SINUMERIK 808D
ADVANCED alarms
System responses
SINAMICS V70 faults and
alarms
Data backup
Updating software
Appendix A
1
2
3
4
5
6
7
8
9
A
Related Manuals for Siemens SINUMERIK 808D ADVANCED
Summary of Contents for Siemens SINUMERIK 808D ADVANCED
-
Contents
-
Table of Contents
-
Bookmarks
Quick Links
SINUMERIK
SINUMERIK 808D ADVANCED
Diagnostics Manual
Diagnostics Manual
06/2015
6FC5398-6DP10-0BA2
Preface
Fundamental safety
instructions
Introduction
Operating in the system data
management operating area
Operating in the alarm
operating area
SINUMERIK 808D
ADVANCED alarms
System responses
SINAMICS V70 faults and
alarms
Data backup
Updating software
Appendix A
1
2
3
4
5
6
7
8
9
A
Related Manuals for Siemens SINUMERIK 808D ADVANCED
Summary of Contents for Siemens SINUMERIK 808D ADVANCED
-
Contents
-
Table of Contents
-
Bookmarks
Quick Links
SINUMERIK
SINUMERIK 808D, SINUMERIK 808D ADVANCED
Service Manual
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The
notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage
have no safety alert symbol. These notices shown below are graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of
injury to persons with a safety alert symbol may also include a warning relating to property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with
the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their
training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products
and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage,
installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any
problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed.
© Siemens AG 2017. All rights reserved
01/2017
1
Summary of Contents for Siemens SINUMERIK 808D
Myp1cBel_ru
%_N_MYPLC_UK_COM
;$PATH=/_N_MB_DIR
700000
0 0 «Приводы станка не
готовы»
700001
0 0 «Выключился защитный
автомат двигателя гидравлики»
700002
0 0 «Выключился некоторый
защитный автомат асинхронных двигателей»
700003
0 0 «Ошибка смазки
направляющей нижнего суппорта
«
700004
0 0 «Ошибка смазки
направляющей задней бабки»
700005
0 0 «Ошибка смазки
направляющей верхнего суппорта»
700006
0 0 «Ошибка смазочной
константы 14510[0] <200-990>»
700007
0 0 «Количество смазочных
впрысков вне диапазона 14510[1]
<1-5>»
700008
0 0 «Ошибка смазки блоков
люнета»
700009
0 0 «Ошибка смазочной
константы 14510[4] <60 — 990>»
700010
0 0 «Перемена зажимного
режима при M3/M4»
700011
0 0 «Старт главного
шпинделя и деталь не зажата»
700013
0 0 «Ошибка положения
зажимного цилиндра патрона при M3/M4»
700014
0 0 «Ошибка давления
зажимного цилиндра патрона при M3/M4»
700020
0 0 «Ошибка положения
пиноли задней бабки при M3/M4»
700021
0 0 «Ошибка давления
пиноли задней бабки при M3/M4»
700022
0 0 «Задняя бабка в левом
лимитном положении»
700023
0 0 «M62/M63/M64 и пиноль
задней бабки не задвинута»
700024
0 0 «Временной контроль
за функцией M62/M63/M64»
700025
0 0 «M66 — а шпиндель
работает»
700027
0 0 «Временной контроль
функции M65 или M66»
700032
0 0 «Сжатая кнопка C-STOP»
700033
0 0 «Станок выключен»
700034
0 0 «Аварийные выключатели
шунтированы»
700035 0 0 «Аварийное положение оси +X»
700036 0 0 «Аварийное положение оси -X»
700037 0 0 «Аварийное положение оси +Z»
700038 0 0 «Аварийное положение оси -Z»
700039 0 0 «Аварийное положение оси +W»
700040 0 0 «Аварийное положение оси -W»
700041
0 0 «Приводы блокированы
открытым кожухом»
700042
0 0 «Низкий уровень
гидравлического масла»
700043
0 0 «Загрязненный фильтр
гидравлического масла»
700044
0 0 «Низкий уровень
смазочного масла»
700045
0 0 «Низкий уровень
смазочного масла блоков люнета»
700046
0 0 «CNC не готова»
700047 0 0 «Корпус люнета не выдвинут
относительно обрабатываемой детали»
700048
0 0 «Сухари люнета
несовершенно разжаты»
700049
0 0 «Низкое зажимное
давление люнета»
700050
0 0 «Зажимной цилиндр
патрона в крайнем положении»
700051
0 0 «Низкое давление в
зажимном цилиндре патрона»
700052
0 0 «Пиноль задней бабки
в левом лимитном положении»
700053
0 0 «Низкое давление
пиноли задней бабки»
700054
0 0 «Корпус задней бабки
в левом крайнем положении»
700055
0 0 «Пиноль не задвинута
— корпус задней бабки нельзя перемещать»
700056
0 0 «Эталонируй оси или
после RESET позволено движение осей»
700059
0 0 «Старт цикла блокирован
положением зам. кнопки кожуха»
700060
0 0 «Инструментальная
головка не вышла в позицию»
700100
0 0 «Ошибка четности
кода позиции инструментальной головки»
700101
0 0 «Заданная позиция
инструментальной головки вне диапазона»
700103
0 0 «Функция люнета
ошибочная в отношении к его состоянию»
700104
0 0 «Ошибка давления
сухарей люнета при M3/M4»
700105
0 0 «Временной контроль
за арретированием инструментальной
головки»
700106
0 0 «Временной контроль
за вращением инструментальной головки»
700108
0 0 «Временной контроль
за функцией люнета «
700109
0 0 «M79, a шпиндель работает»
700110 0 0 «Ошибка управления кожухом»
700111
0 0 «Защитные рейки
кожуха были нажаты»
700112
0 0 «Временной контроль
за функцией M51 или M52»
700115 0 0 «Временной
контроль за функцией SPOS — установка
позиции главного шпинделя
«
700116 0 0 «Функции
М3 / М4 и режим оси С — активный»
700117
0 0 «Временной контроль
за функцией М14 или M15»
700118
0 0 «М14 — а ось С не
находится в эталонном положении»
700119
0 0 «M14 — а шпиндель не
ориентирован «
700120 0 0 «Временной контроль за
переключением — функция M41/M42»
700121
0 0 «M41/M42 — а главный
шпиндель находится в режиме оси C»
700125
0 0 «Временной контроль
за ориентацией инструментального
шпинделя»
700126
0 0 «Перегрузка двигателя
транспортера стружки»
700127
0 0 «Ошибка измерительного
щупа»
700132
0 0 «Слабая батарея щупа»
700134
0 0 «Стоп перемещения
осей переключателем»
700135
0 0 «Стоп перемещения
осей и шпинделя переключателем»
700136
0 0 «Действительная
скорость вращения главного шпинделя
слишком высока»
700138
0 0 «Не достигнуто
заданное число оборотов главного
шпинделя»
700139
0 0 «Действительные
обороты инструментального шпинделя
слишком высоки»
700141
0 0 «Заданная скорость
вращения инструментального шпинделя
не достигнута»
700143
0 0 «Стоп оборотов с
ручного переносного пульта»
700144
0 0 «Стоп подач с ручного
переносного пульта»
700145
0 0 «Двигатель оси С — в
промежуточном положении»
700146
1 0 «Не установлена
ступень переключения для главного
шпинделя»
700149
0 0 «Функция M2=3/M2=4 и
T-функции программированы в одном блоке»
M02
Соседние файлы в папке RUSTINA
- #
- #
|
|
Ремонт SINUMERIK 808D
Компания «Кернел» производит ремонт ЧПУ с 2002 года. За это время мы накопили колоссальный опыт в том числе опыт в ремонте SINUMERIK 808D такого известного производителя как SIEMENS. Ремонт подобной промышленной электроники ответственное и сложное занятие, требующие максимальной отдачи, профессионализма и максимально полной материальной базе.
Ремонт SINUMERIK 808D в производится как в сервисном центре, так и с выездом специалиста на территорию заказчика. SINUMERIK 808D является крайне сложной промышленной электроникой соответственно ремонт SINUMERIK 808D можно доверить только настоящим профессионалам своего дела с богатым опытом работы в данном направлении.
Все специалисты нашего сервисного центра имеют высшее техническое образование, огромный опыт и максимально полную материальную базу включая новейшее высокотехнологичное диагностическое оборудование благодаря чему ремонт SINUMERIK 808D проходит максимально эффективно.
Инженеры сервисного центра уделяют максимальное внимание к качеству исполнения ремонта, программирования и настройке ЧПУ, не зависимо от производителя данного промышленного оборудования. Именно поэтому мы смело даем гарантию на ремонт SINUMERIK 808D и замененные в процессе ремонта компоненты шесть месяцев.
Особое внимание заслуживает тот факт, что ремонт SINUMERIK 808D в производится исключительно с использованием оригинальных запасных частей, на компонентном уровне с применением высокотехнологичного оборудования, квалифицированным персоналом с инженерным образованием.
Если на вашем производстве появились проблемы с ЧПУ SINUMERIK 808D, которые вы не можете решить самостоятельно, мы всегда рады вам помочь. Обращайтесь в сервисный центр «Кернел». Специалисты нашей компании в минимальные сроки проведут глубокую диагностику ЧПУ и последующий ремонт SINUMERIK 808D в . Оставьте аявку на ремонт ЧПУ используя форму на сайте.
Ошибки SINUMERIK 808D
Сообщения об ошибках SINUMERIK 808D и обработка ошибок
При возникновении ошибок при выполнении циклов выдается сигнал и выполнение цикла прерывается. Кроме того, сообщения циклов выводятся в строке сообщений СЧПУ. Эти сообщения не прерывают выполнение программы. Ошибки с их действием и сообщениями в строке сообщений СЧПУ описаны совместно с описанием конкретных циклов.
Обработка ошибок SINUMERIK 808D в циклах
В циклах генерируются сообщения об ошибках с номерами от 61000 до 62999. Диапазон номеров, в свою очередь, снова делится в соответствии с реакциями на ошибки и критериями отмены. Текст ошибки, который отображается вместе с номером ошибки, предоставляет более подробную информацию о причине ошибки.
Номер ошибки |
Критерий сброса |
Реакция на ошибку |
61000 … 61999 |
NC_RESET |
Подготовка кадра в СЧПУ прервана |
62000 … 62999 |
Кнопка сброса |
Прерывается подготовка кадра; цикл может быть продолжен нажатием следующей клавиши на MCP после удаления ошибки: |
Обзор ошибок циклов SINUMERIK 808D
Номера ошибок классифицируются следующим образом:
6 |
_ |
Х |
_ |
_ |
- X=0 Общие ошибки циклов
- X=1 Ошибки, возникшие при сверлении, фрезеровании
- X=6 Ошибки, возникшие в циклах токарной обработки
Сообщения циклов SINUMERIK 808D
Сообщения циклов выводятся в строке сообщений СЧПУ. Эти сообщения не прерывают выполнение программы. Сообщения предоставляют информацию относительно поведения циклов хода обработки и, как правило, хранятся за пределами рабочей операции или до конца цикла. Пример сообщения: «Глубина: в соответствии со значением относительной глубины» для всех циклов сверления.
Все ошибки SINUMERIK 808D описаны в руководстве пользователя, которое вы можете скачать с нашего сайта в удобном формате- pdf.
Скачать руководство пользователя (диагностика) SINUMERIK 808D мануал.pdf
Устранение причины ошибки и ее сброс на станке оснащенным системой ЧПУ позволит в кратчайшие сроки возобновить работу. К сожалению не все ошибки можно исправить самостоятельно, некоторые ошибки SINUMERIK 808D возможно исправить только в специализированных сервисных центрах.
SINUMERIK 808D программирование
На ряду с ремонтом, специалисты сервисного центра «Кернел» выполняют программирование SINUMERIK 808D и настройку параметров системы ЧПУ. Подобную услугу мы оказываем не только на территории сервисного центра, также инженер компании может выполнить программирование SINUMERIK 808D на территории заказчика.
Настройка параметров, программирование SINUMERIK 808D является заключительным звеном в процессе ремонта ЧПУ и требует профессионального подхода. Именно финальный этап программирования SINUMERIK 808D наглядно покажет качество выполненного ремонта SINUMERIK 808D.
К слову, мы уделяем особое внимание качеству и смело даем гарантию на все выполненные ремонтно-восстановительные работы шесть месяцев, гарантия так же распространяется на запасные части, которые были заменены в процессе ремонта.
Хочется обратить внимание на то, что мы стараемся провести ремонт и программирование SINUMERIK 808D в максимально сжатые сроки, тем самым минимизируем простой дорогостоящего промышленного оборудования.
Дополнительно можно скачать руководство по программированию SINUMERIK 808D в формате- pdf
Скачать руководство пользователя (программирование) SINUMERIK 808D мануал.pdf
SINUMERIK 808D ввод в эксплуатацию
Инженеры сервисного центра «Кернел» не только выполняют качественный ремонт SINUMERIK 808D и программирование ЧПУ в . Так же мы предоставляем услугу запуска в эксплуатацию оборудования от стадии проектирования до выпуска первой продукции.
Именно этап запуска в эксплуатацию SINUMERIK 808D отвечает за долгий и безаварийный процесс работы промышленного оборудования, тем самым позволяя получить максимальную прибыль и сэкономить на незапланированном ремонте.
По-настоящему качественный ввод в эксплуатацию SINUMERIK 808D может выполнить только высококвалифицированный специалист с богатым опытом работы в данном направлении. Найти подобного специалиста достаточно сложно, но, если вы обращаетесь в наш сервисный центр вам не придется об этом думать.
В нашей команде работают исключительно профессионалы своего дела, а за время существования нашей компании мы ввели в эксплуатацию не одну сотню систем ЧПУ в том числе и SINUMERIK 808D, с каждым разом получая и накапливая драгоценный опыт.
О SINUMERIK 808D
SINUMERIK 808D объединяет в себе качественно сконфигурированную систему ЧПУ предназначенную для работы на фрезерных и токарных станках.
Пример сборки для токарной обработки с помощью SINUMERIK 808D ADVANCED T
Описание |
Колл-во |
Артикул |
SINUMERIK CNC |
||
SINUMERIK 808D ADVANCED T PPU 160.3 vertical, English layout |
1 |
6FC5370-2BT03-0AA0 |
SINUMERIK 808D MCP vertical, with handwheel slot, English layout |
1 |
6FC5303-0AF35-3AA0 |
Stabilized power supply, SITOP PSU200M 24 V DC, 5 A |
1 |
6EP1333-3BA10 |
RS422 (TTL) incremental encoder, 1024 S/R |
1 |
6FX2001-2EB02 |
Spring disk coupling, shaft diameter 6 mm/6 mm |
1 |
6FX2001-7KF10 |
Clamp strap for encoders with Synchro flange |
3 |
6FX2001-7KP01 |
Pre-assembled bus cable PPU 160.3 – SINAMICS V70, length 5 m |
1 |
6FC5548-0BA20-1AF0 |
Pre-assembled bus cable SINAMICS V70 – SINAMICS V70, length 0.25 m |
2 |
6FC5548-0BA20-1AA2 |
Pre-assembled signal cable PPU 160.3 – handwheel, length 1 m |
1 |
6FX8002-2BB01-1AB0 |
Pre-assembled signal cable PPU 160.3 – incremental spindle encoder (TTL), length 5 m |
1 |
6FX8002-2CD01-1AF0 |
SINAMICS V70 |
||
SINAMICS V70, Irated 3.0 A |
1 |
6SL3210-5DE13-5UA0 |
SINAMICS V70, Irated 5.3 A |
1 |
6SL3210-5DE17-8UA0 |
SINAMICS V70 spindle1), Irated 19.6 A |
1 |
6SL3210-5DE22-0UA0 |
Pre-assembled signal cable SINAMICS V70 – absolute encoder in SIMOTICS S-1FL6 feed motor, length 5 m |
2 |
6FX3002-2DB10-1AF0 |
Pre-assembled power cable 4 × 1.5 mm2 |
2 |
6FX3002-5CL02-1AF0 |
Pre-assembled power cable 4 × 2.5 mm2 |
1 |
6FX3002-5CL12-1AF0 |
Pre-assembled brake cable SINAMICS V70 – brake in SIMOTICS S-1FL6 feed motor with holding brake, length 5 m |
1 |
6FX3002-5BL03-1AF0 |
Pre-assembled signal cable SINAMICS V70 – incremental encoder in M-1PH1, length 5 m |
1 |
6FX3002-2CT30-1AF0 |
Power cable 4 × 4 mm2, sold by the meter, (optional)2) SINAMICS V70 – SIMOTICS M-1PH1 main spindle motor, length 30 m |
1 |
6FX5008-1BB31-1DA0 |
SIMOTICS motors |
||
SIMOTICS S-1FL6 feed motor, 4 Nm, 2000 rpm, absolute encoder, plain shaft, without holding brake |
1 |
1FL6061-1AC61-2LG1 |
SIMOTICS S-1FL6 feed motor, 11 Nm, 2000 rpm, absolute encoder, plain shaft, with holding brake |
1 |
1FL6066-1AC61-2LH1 |
SIMOTICS M-1PH1 main spindle spindle motor, 53 Nm, 1000 rpm, incremental encoder, plain shaft |
1 |
1PH1105-1LD10-0GA0 |
Пример сборки для фрезерования с помощью SINUMERIK 808D ADVANCED M
Описание |
Колл-во |
Артикул |
SINUMERIK CNC |
||
SINUMERIK 808D ADVANCED M PPU 161.3 horizontal, English layout |
1 |
6FC5370-2AM03-0AA0 |
SINUMERIK 808D MCP horizontal, English layout |
1 |
6FC5303-0AF35-0AA0 |
Electronic handwheel, with front plate 120 mm × 120 mm, with setting wheel, 5 V DC, RS 422 |
1 |
6FC9320-5DB01 |
Terminal strip converter 50-pole |
1 |
6EP5406-5AA00 |
Cable set, 50-pole ribbon cable, with insulation displacement connectors, 50-pole |
1 |
6EP5306-5BG00 |
Stabilized power supply, SITOP PSU200M 24 V DC, 5 A |
1 |
6EP1333-3BA10 |
Pre-assembled bus cable PPU 161.3 – SINAMICS V70, length 5 m |
1 |
6FC5548-0BA20-1AF0 |
Pre-assembled bus cable SINAMICS V70 – SINAMICS V70, length 0.25 m |
2 |
6FC5548-0BA20-1AA2 |
Pre-assembled signal cable PPU 161.3 – handwheel, length 1 m |
1 |
6FX8002-2BB01-1AB0 |
Pre-assembled signal cable PPU 161.3 – incremental spindle encoder (TTL), length 7 m |
1 |
6FX8002-2CD01-1AH0 |
SINAMICS V70 |
||
SINAMICS V70, Irated 4.6 A |
2 |
6SL3210-5DE16-0UA0 |
SINAMICS V70, Irated 7.8 A |
1 |
6SL3210-5DE21-0UA0 |
SINAMICS V70 spindle1), Irated 19.6 A |
1 |
6SL3210-5DE22-0UA0 |
Pre-assembled signal cable SINAMICS V70 – incremental encoder in SIMOTICS S-1FL6 feed motor, length 10 m |
3 |
6FX3002-2CT12-1BA0 |
Pre-assembled power cable 4 × 2.5 mm2 |
3 |
6FX3002-5CL12-1BA0 |
Pre-assembled signal cable SINAMICS V70 – brake in SIMOTICS S-1FL6 feed motor, length 10 m |
1 |
6FX3002-5BL03-1BA0 |
Pre-assembled signal cable SINAMICS V70 – incremental encoder in M-1PH1, length 10 m |
1 |
6FX3002-2CT30-1BA0 |
Power cable 4 × 4 mm2, sold by the meter, (optional)2) SINAMICS V70 – SIMOTICS M-1PH1 main spindle motor, length 30 m |
1 |
6FX5008-1BB31-1DA0 |
SIMOTICS motors |
||
SIMOTICS S-1FL6 feed motor, 8 Nm, 2000 rpm, incremental encoder, plain shaft, without holding brake |
2 |
1FL6064-1AC61-2AG1 |
SIMOTICS S-1FL6 feed motor, 15 Nm, 2000 rpm, incremental encoder, plain shaft, with holding brake |
1 |
1FL6067-1AC61-2AH1 |
SIMOTICS M-1PH1 main spindle motor, 48 Nm, 1500 rpm, incremental encoder, plain shaft |
1 |
1PH1105-1LF12-0GA0 |
1) Выбор тормозного резистора см. В приводе шпинделя SINAMICS V70.
2) Перечисленные выше 30-метровые силовые кабели (необработанные) можно выбрать для использования с двигателями 1PH1. Вы должны собрать кабель питания с разъемами самостоятельно. Вы также можете выбрать сторонний кабель питания в соответствии с конфигурацией системы.
SINUMERIK 808D выполнен в двух вариантах:
- Горизонтальное исполнение (SINUMERIK 808D PPU 261.3/PPU 281.3);
- Вертикальное исполнение (SINUMERIK 808D PPU 260.3/PPU 280.3).
SINUMERIK 808D это моноблочная система ЧПУ, объединяющая в одном устройстве все компоненты СЧПУ:
- ЧПУ, PLC, HMI;
- полная клавиатура СЧПУ;
- регулятор для 6 приводов.
Двигатели могут подключаться напрямую через DRIVE-CLiQ к цифровой приводной системе. В комбинации с модульным исполнением приводной системы SINAMICS S120 получается простая и надежная конструкция с минимальным объемом межкомпонентных соединений.
Обзор соединений SINUMERIK 808D
Точно подобранный набор функций системы ЧПУ для стандартных токарных и фрезерных станков отвечает всем требованиям мелко- и крупносерийного производства. Специально подобранные системные параметры для токарной и фрезерной технологии позволяют значительно сократить расходы на ввод станка в эксплуатацию.
Моноблочная система ЧПУ крепится с задней стороны с помощью специальных элементов, входящих в объем поставки.
Линейка промышленной электроники, которую восстанавливают специалисты сервисного центра «Кернел» не имеет ограничений, мы выполняем качественный ремонт промышленной электроники и оборудования абсолютно любых производителей не зависимо от года выпуска и наличия технической документации.
Ниже приведен далеко не полный список ЧПУ SINUMERIK 808D ремонт которых предлагает наш сервисный центр.
6FC5370-2BM03-0AA0 6FC5370-2BM03-0CA0 6FC5370-2BT03-0AA0 6FC5370-2BT03-0CA0 |
6FC5370-3BM03-0AA0 6FC5370-3BM03-0CA0 6FC5370-3BT03-0AA0 6FC5370-3BT03-0CA0 |
6FC5303-0AF35-0AA0 SINUMERIK 808D Machine control panel 6FC5303-0AF35-2AA0 SINUMERIK 808D Machine control panel vertical 6FC5303-0AF35-3AA0 SINUMERIK 808D Machine control panel vertical |
Оставить заявку на ремонт или программирование SINUMERIK 808D
Оставить заявку на ремонт или программирования SINUMERIK 808D в можно с помощью специальной формы, которая вызывается нажатием одноименной кнопки в верхней части страницы. Все вопросы, связанные с ремонтом SINUMERIK 808D в вы можете задать нашим менеджерам. Связаться с ними можно несколькими способами:
- Заказав обратный звонок (кнопка в правом нижнем углу сайта)
- Посредством чата (кнопка расположена с левой стороны сайта)
- Позвонив по номеру телефона: +7(8482) 79-78-54; +7(917) 121-53-01
- Написав на электронную почту: 89171215301@mail.ru
Вот далеко не полный список производителей промышленной электроники и оборудования, ремонтируемой в нашей компании.