Заказать сегодня Ошибки Kyocera ECOSYS M8130cidn с гарантией . Доступно к заказу. Информация о продукте, опции и расходные материалы, спецификации, драйверы, фото, купить по выгодной цене. Мы являемся поставщиком продукции Kyocera в России. Контакты: ✔ info@alggroup.ru, ☎ +7 (495) 208-47-48. Полный каталог товаров и прайс на сайте ☞ kyocera-msk.ru
  • Code: C0070
  • Description: FAX PWB incompatible detection error
  • Causes: Abnormal detection of FAX control PWB incompatibility in the initial communication with the FAX control PWB, any normal communication command is not transmitted.
  • Remedy: 1 Checking the FAX PWB The incompatible FAX PWB is installed. Install the FAX PWB for the applicable model. 2 Firmware upgrade The FAX firmware is faulty. Reinstall the FAX firmware. 3 Replacing the main PWB The main PWB is faulty. Replace the main PWB.
  • Code: C0100
  • Description: Backup memory device error
  • Causes: An abnormal status is output from the flash memory.
  • Remedy: 1 Resetting the main power The flash memory does not operate properly. Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Checking the main PWB The connector or the FFC is not connected properly. Or, the wire, FFC, the PWB is faulty. Clean the terminal of the connectors on the main PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main PWB.
  • Code: C0120
  • Description: MAC address data error
  • Causes: The MAC address data is incorrect.
  • Remedy: 1 Resetting the main power The flash memory does not operate properly. Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Checking the MAC address The MAC address is incorrect. Replace the main PWB when the MAC address is not indicated on the network status page.
  • Code: C0130
  • Description: Backup memory reading/writing error
  • Causes: The reading or writing into the flash memory is unavailable.
  • Remedy: 1 Resetting the main power The flash memory does not operate properly. Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Checking the main PWB The connector or the FFC is not connected properly. Or, the wire, FFC, the PWB is faulty. Clean the terminal of the connectors on the main PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main PWB.
  • Code: C0140
  • Description: Backup memory data error
  • Causes: The flash memory data read at the initial start-up is faulty
  • Remedy: 1 Resetting the main power The flash memory does not operate properly. Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Checking the main PWB The connector or the FFC is not connected properly. Or, the wire, FFC, the PWB is faulty. Clean the terminal of the connectors on the main PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main PWB.
  • Code: C0150
  • Description: Engine EEPROM reading / writing error
  • Causes: 1. Continuous five times detection of no response from the device for 5ms or more on reading / writing. 2. Data read twice do not match continuous 8 times. 3. Writing data and reading data do not match continuous 8 times.
  • Remedy: 1 Resetting the main power The EEPROM on the engine PWB does not operate properly. Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Checking the EEPROM on the engine PWB The EEPROM is not properly attached. Reattach the EEPROM on the engine PWB. 3 Replacing the EEPROM The EEPROM is faulty. 1. Print Maintenance Report at U000 beforehand. 2. Replace the EEPROM on the engine PWB. C6990 appears when turning the power on. Execute U169 at that state. 3. Then, print Maintenance Report at U000. Compare the setting values with Maintenance Report printed before and change the different values. (Target maintenance mode: U063, U100, U127, U140, U161, U465, U468 and U901, etc.) 4. Check the output image and adjust the image at U410, U411, etc. if necessary. 4 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C0160
  • Description: EEPROM data error
  • Causes: The data read from the EEPROM is judged as abnormal.
  • Remedy: 1 Resetting the main power The EEPROM on the engine PWB does not operate properly. Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Executing U021 The storage data in the EEPROM on the engine PWB is faulty. Execute U021. 3 Replacing the EEPROM The EEPROM is faulty. 1. Print Maintenance Report at U000 beforehand. 2. Replace the EEPROM on the engine PWB. C6990 appears when turning the power on. Execute U169 at that state. 3. Then, print Maintenance Report at U000. Compare the setting values with Maintenance Report printed before and change the different values. (Target maintenance mode: U063, U100, U127, U140, U161, U465, U468 and U901, etc.) 4. Check the output image and adjust the image at U410, U411, etc. if necessary. 4 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C0170
  • Description: Charger count error
  • Causes: 1. Errors are detected in both backup memory of the engine PWB charge counter and main PWB charge counter. 2. Main PWB counter data and engine PWB counter date are faulty
  • Remedy: 1 Replacing the main PWB The main PWB is faulty. Replace the main PWB and execute U004 2 Replacing the EEPROM on the engine PWB The EEPROM is faulty. 1. Print Maintenance Report at U000 beforehand. 2. Replace the EEPROM on the engine PWB. C6990 appears when turning the power on. Execute U169 at that state. 3. Then, print Maintenance Report at U000. Compare the setting values with Maintenance Report printed before and change the different values. (Target maintenance mode: U063, U100, U127, U140, U161, U465, U468 and U901, etc.) 4. Check the output image and adjust the image at U410, U411, etc. if necessary. 3 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C0180
  • Description: Machine serial number mismatch
  • Causes: The machine serial Nos. in the main PWB and the EEPROM on the engine PWB mismatch when turning the power on.
  • Remedy: 1 Checking the machine serial No. of the main PWB The main PWB for the different main unit is installed. Check the machine serial Nos of MAIN and ENGINE at U004, and install the correct main PWB if the MAIN No. differs. 2 Checking the machine serial No. in the EEPROM on the engine PWB The EEPROM for the different main unit is installed. Check the machine serial Nos of MAIN and ENGINE at U004, and install the correct EEPROM on the engine PWB if the ENGINE machine serial No. differs. 3 Replacing the main PWB The main PWB is faulty. When the MAIN machine serial No. differs at U004, replace the main PWB and execute U004. 4 Checking the EEPROM on the engine PWB The EEPROM is faulty. If the machine serial number on the engine PWB is different at U004, reattach the EEPROM. If not repaired, replace the EEPROM on the engine PWB by referring to the following procedures. 1. Print Maintenance Report at U000 beforehand. 2. Replace the EEPROM on the engine PWB. C6990 appears when turning the power on. Execute U169 at that state. 3. Then, print Maintenance Report at U000. Compare the setting values with Maintenance Report printed before and change the different values. (Target maintenance mode: U063, U100, U127, U140, U161, U465, U468 and U901, etc.) 4. Check the output image and adjust the image at U410, U411, etc. if necessary. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C0190
  • Description: Backup memory device error (Engine)
  • Causes: Data from the main unit IC cannot be read out at power-up
  • Remedy: 1 Resetting the main power The IC in the engine PWB does not operate normally Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C0500
  • Description: Drive lock detected by the engine firmware
  • Causes: During the engine steady state control, the main motor drive continued 60 minutes or more (except during the maintenance mode)
  • Remedy: 1 Resetting the main power The firmware in the engine PWB does not operate normally Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C0510
  • Description: Main charger control error
  • Causes: The main charger bias turns on while the drum stops.
  • Remedy: 1 Resetting the main power The firmware in the engine PWB does not operate normally Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C0520
  • Description: Developer control error
  • Causes: The developer bias off is detected during the main charge bias off
  • Remedy: 1 Resetting the main power The firmware in the engine PWB does not operate normally Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C0530
  • Description: Backup task error
  • Causes: No operation 30s or more when monitoring the backup task operation
  • Remedy: 1 Resetting the main power The firmware in the engine PWB does not operate normally Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C0800
  • Description: Image processing error
  • Causes: The print sequence jam (J010x) is detected 2 times continuously.
  • Remedy: 1 Checking the image data The image data is faulty. When this issue occurs only when handling the certain image data, check if the image data is faulty. 2 Checking the situation The printing operation of the certain file is faulty. Acquire the job’s log if the phenomenon can be reproduced by specifying the job when the error was detected. 3 Checking the main PWB The connector or the FFC is not connected properly. Or, the wire, FFC, the PWB is faulty. Clean the terminal of the connectors on the main PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main PWB.
  • Code: C0830
  • Description: FAX PWB flash program area checksum error
  • Causes: The program stored in the flash memory on the FAX PWB is broken so it cannot perform.
  • Remedy: 1 Resetting the main power The FAX PWB is not connected properly. Turn off the power switch and pull out the power plug. After passing 5s, reattach the FAX PWB and reinsert the power plug. Then, turn on the power switch. 2 Firmware upgrade The firmware is faulty. Reinstall the FAX firmware. 3 Initializing the fax The data in the FAX PWB is faulty. Execute U600 to initialize the FAX. 4 Replacing the FAX PWB The FAX PWB is faulty. Replace the FAX PWB. Step
  • Code: C0840
  • Description: RTC error
  • Causes: • Not communicated with RTC correctly. • RTC data is inconsistent with empty battery.
  • Remedy: 1 Setting time and date (RTC) Time and date (RTC) are erased Set Date and Time (RTC) from System Menu 2 Replacing the main PWB The main PWB is faulty, or the backup battery runs out. Replacing the main PWB
  • Code: C0870
  • Description: PC FAX Image data transmission error
  • Causes: Data was not properly transmitted even if the specified times of retry were made when the large volume data is transmitted between the FAX PWB and the main PWB.
  • Remedy: 1 Resetting the main power The FAX PWB does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reattach the FAX PWB and reinsert the power plug. Then, turn on the power switch. 2 Initializing the fax The data in the FAX PWB is faulty. Execute U600 to initialize the FAX. 3 Firmware upgrade The FAX firmware is faulty. Upgrade the fax firmware to the latest version. 4 Replacing the FAX PWB The FAX PWB is faulty. Replace the FAX PWB. 5 Replacing the main PWB The main PWB is faulty. Replace the main PWB.
  • Code: C0920
  • Description: FAX file system error
  • Causes: The backup data could not be stored since the file system of the flash memory is faulty.
  • Remedy: 1 Resetting the main power The FAX PWB does not operate properly. Turn off the power switch and pull out the power plug. After passing 5s, reattach the FAX PWB and reinsert the power plug. Then, turn on the power switch. 2 Initializing the fax FAX control values are incorrect Execute U600 to initialize the FAX. 3 Reconnecting the FAX PWB The FAX PWB is not connected properly. Reinstall FAX PWB to Main PWB. 4 Firmware upgrade The firmware is faulty. Reinstall the FAX firmware. 5 Replacing the FAX PWB The FAX PWB is faulty. Replace the FAX PWB.
  • Code: C0980
  • Description: 24V power interruption detection
  • Causes: • 24V power shutoff signal is detected 1s continuously. • Other service call error occurs after 24V power shutoff signal is lowered, and then 24V power is recovered.
  • Remedy: 1 Resetting the main power The firmware in the engine PWB does not operate normally Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Low-voltage PWB — Engine PWB 3 Replacing the low voltage PWB The low voltage PWB is faulty. When the +24V generation from the low voltage PWB is not stable, and it lowers, replace the low voltage PWB. 4 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C1010
  • Description: Lift motor 1 error
  • Causes: • Cassette 1 lift motor over-current is detected 5 times continuously. • Lift sensor on is not detected 5 times continuously when passing 15s after cassette 1 is loaded.
  • Remedy: 1 Checking the lift plate The lift plate does not operate properly. Repair or replace the lift plate when it does not move vertically. 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Lift motor — Engine PWB(YC15) • Lift sensor — Engine PWB(YC15) 3 Checking the lift motor The lift motor is faulty. Check the lift motor operation, and replace it if necessary. 4 Checking the lift sensor The lift sensor is not properly attached, or it is faulty. Reattach PF lift upper limit sensor. If not repaired, replace it. 5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C1020
  • Description: PF lift motor 1 error Object: 500-sheet paper feeder, 500-sheetx2 paper feeder
  • Causes: The PF lift sensor 1 on is not detected 5 times continuously when passing 15s after loading cassette 2.
  • Remedy: 1 Checking the lift plate The lift plate does not operate properly. Repair or replace the lift plate when it does not move vertically. 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • PF lift moor 1 — PF PWB (YC4) • PF upper limit sensor 1 — PF PWB (YC3) 3 Checking PF lift motor 1 PF lift motor 1 is faulty. Check the operation of lift motor 1, and replace it if necessary. 4 Checking PF lift sensor 1 PF lift sensor 1 is not properly attached, or it is faulty. Reattach PF lift sensor 1. If not repaired, replace it. 5 PF firmware upgrade The PF firmware is not the latest version. Upgrade the PF firmware to the latest version. 6 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB.
  • Code: C1030
  • Description: PF lift motor 2 error Object: 500-sheetx2 paper feeder
  • Causes: The PF lift sensor 2 on is not detected 5 times continuously when passing 15s after loading cassette 3.
  • Remedy: 1 Checking the lift plate The lift plate does not operate properly. Repair or replace the lift plate when it does not move vertically. 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • PF lift moor 2 — PF PWB (YC6) • PF upper limit sensor 2 — PF PWB (YC5) 3 Checking PF lift motor 2 PF lift motor 2 is faulty. Check the operation of lift motor 2, and replace it if necessary. 4 Checking PF lift sensor 2 PF lift sensor 2 is not properly attached, or it is faulty. Reattach PF lift sensor 2. If not repaired, replace it. 5 PF firmware upgrade The PF firmware is not the latest version. Upgrade the PF firmware to the latest version. 6 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB.
  • Code: C1800
  • Description: Paper Feeder communication error Object: 500-sheet paper feeder, 500-sheetx2 paper feeder
  • Causes: The communication error was detected 10 times continuously.
  • Remedy: 1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Engine PWB (YC25) — PF PWB(YC1) 2 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware and PF firmware to the latest version 3 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB. 4 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C1900
  • Description: Paper Feeder EEPROM error Object: 500-sheet paper feeder, 500-sheetx2 paper feeder For internal count
  • Causes: The writing data and the reading data mismatch 4 times continuously when writing.
  • Remedy: 1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Engine PWB (YC25) — PF PWB(YC1) 2 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware and PF firmware to the latest version 3 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB. 4 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C2101
  • Description: Developer motor K steady-state error
  • Causes: Developer motor K steady state off is detected for 1s continuously after becoming the steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Developer motor K — Engine PWB (YC18) 3 Checking the drive unit The drive unit is faulty. Execute U030 [Dlp(K)/Drum] and check the developer motor K operation. If there are any load for the gear rotation inside the drive unit replace drive unit B. 4 Replacing the developer motor The developer motor is faulty. Replace developer motor K. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C2102
  • Description: Developer motor CMY steady-state error
  • Causes: Developer motor CMY steady state off is detected 1s continuously after becoming the steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Developer motor CMY — Engine PWB (YC19) 3 Checking the drive unit The drive unit is faulty. Execute U030 [Dlp(Col)] and check the drum motor CMY operation. If there are any load for the gear rotation inside the drive unit replace drive unit A. 4 Replacing the developer motor The developer motor is faulty. Replace developer motor CMY. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C2201
  • Description: Drum motor K steady-state error
  • Causes: Drum motor K steady state off is detected for 1s continuously after becoming the steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drum motor K — Engine PWB (YC19) 3 Checking the drive unit The drive unit is faulty. Execute U030 [Dlp(K)/Drum] and check the drum motor K operation. If there are any load for the gear rotation inside the drive unit replace drive unit A. 4 Replacing drum motor K Drum motor K is faulty. Replace drum motor K. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C2202
  • Description: Drum motor CMY steady-state error
  • Causes: Drum motor CMY steady state off is detected 1s continuously after becoming the steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drum motor CMY — Engine PWB (YC19) 3 Checking the drive unit The drive unit is faulty. Execute U030 [Dlp(K)/Drum] and check the drum motor CMY operation. If there are any load for the gear rotation inside the drive unit replace drive unit A. 4 Replacing drum motor CMY Drum motor CMY are faulty. Replace drum motor CMY. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C2300
  • Description: Fuser motor steady state error
  • Causes: The fuser motor steady state off is detected 1s continuously after becoming steady state
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Fuser motor — Engine PWB (YC18) 3 Checking the drive unit The drive unit is faulty. Check the fuser motor operation. If there are any load for the gear rotation inside the drive unit replace drive unit B. 4 Replacing the fuser motor The fuser motor is faulty. Replace the fuser motor. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C2310
  • Description: Fuser motor start-up error
  • Causes: The fuser motor is not in the steady state within 1.5s after start-up.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Fuser motor — Engine PWB (YC18) 3 Checking the drive unit The drive unit is faulty. Check the fuser motor operation. If there are any load for the gear rotation inside the drive unit replace drive unit B. 4 Replacing the fuser motor The fuser motor is faulty. Replace the fuser motor. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C2550
  • Description: Conveying motor steady-state error
  • Causes: The conveying motor steady state off is detected 1s continuously after becoming the steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Conveying motor — Engine PWB (YC14) 3 Checking the drive unit The drive unit is faulty. Execute U030 [Feed] and check the feed motor operation. If there are any load for the gear rotation inside the drive unit replace drive unit C. 4 Replacing the conveying motor The conveying motor is faulty. Replace the conveying motor. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C2550
  • Description: Conveying motor startup error
  • Causes: The conveying motor is not in the steady state within 2s after start-up.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Conveying motor — Engine PWB (YC14) 3 Checking the drive unit The drive unit is faulty. Execute U030 [Feed] and check the feed motor operation. If there are any load for the gear rotation inside the drive unit replace drive unit C. 4 Replacing the conveying motor The conveying motor is faulty. Replace the conveying motor. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C2600
  • Description: PF motor error Object: 500-sheet paper feeder, 500-sheetx2 paper feeder
  • Causes: An error signal was detected 2s continuously during the PF motor drive
  • Remedy: 1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • PF motor — PF PWB(YC25) 2 Firmware upgrade The firmware is not the latest version. Upgrade the PF firmware to the latest version. 3 Checking the PF motor The PF motor is faulty Replace the PF motor 4 Replacing the PF PWB The PF PWB is faulty. Replace the PF PWB.
  • Code: C2700
  • Description: Belt release motor error
  • Causes: The error signal is detected for 3s continuously after the belt release motor starts up.
  • Remedy: 1 Firmware upgrade The engine firmware is faulty. Upgrade the engine firmware to the latest version 2 Checking the drive parts The drive transmission of the belt release motor is faulty. Repair the drive transmission parts if the drive from the belt release motor is not transmitted. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Belt release motor — Transfer PWB (YC2) • Belt rotation sensor — Transfer PWB (YC2) • Transfer PWB (YC2) — Transfer relay PWB (YC1) • Transfer relay PWB (YC2) — Engine PWB (YC11) 4 Checking the belt rotation sensor The belt rotation sensor comes off. Reattach or replace the belt rotation sensor. 5 Checking the belt release motor The belt release motor is not operated correctly. Reattach or replace the belt release motor. 6 Primary transfer unit replacement The primary transfer roller liftup drive section is faulty. Replace the primary transfer unit. 7 Replacing the transfer relay PWB The transfer relay PWB is faulty. Replace the transfer relay PWB. 8 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C3100
  • Description: Carriage error Object: CIS model
  • Causes: The home position sensor is off and does not turn on when passing the specified time at initialization and it does not turn on at retry once.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the scanner and ISU shaft A load is applied to the scanner movement. Move the mirror unit manually. If there is heavy load in excess, check the drive belt and clean the ISU shaft. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Scanner motor — Engine PWB (YC12) 4 Checking the scanner motor The scanner motor is faulty. Reattach the scanner motor. If not repaired, replace it. 5 Checking the home position sensor The home position sensor is faulty. Reattach the home position sensor. If not repaired, replace it. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C3100
  • Description: Carriage error Object: LED model
  • Causes: The home position sensor is off and does not turn on when passing the specified time at initialization and it does not turn on at retry once.
  • Remedy: 1 Unlocking the primary mirror unit The primary mirror unit is not unlocked. Unlock the primary mirror unit. 2 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version. 3 Checking the scanner and scanner wire A load is applied to the scanner movement. Move the mirror unit manually. If there is heavy load in excess, clean the scanner wire, wire drum, scanner rail, etc. 4 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Scanner motor — Engine PWB (YC12) 5 Checking the scanner motor and the belt tension. The scanner motor or belt tension is faulty Reattach the scanner motor and adjust the belt tension. If not repaired, replace the scanner motor. 6 Checking the home position sensor The home position sensor is faulty. Reattach the home position sensor. If not repaired, replace it. 7 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C3200
  • Description: LED error Object: LED model
  • Causes: The white reference data retrieved by lighting the lamp at the initial operation is at the specified value or less.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the LED lamp The LED lamp does not light. Check if the LED lamp lights. If it does not light, replace the lamp unit and execute U411 [Table]. 3 Checking the connection The FFC is not correctly connected. Clean the FFC terminals of the following FFC and reconnect them. If the FFC terminal is deformed or broken, replace the FFC. • LED drive PWB — Main PWB (YC3003) 4 Checking the lens unit The CCD PWB is faulty. Clean the FFC terminal and reconnect it. If deformed or broken, replace the FFC. • CCD PWB — Main PWB (YC3002) If not repaired, replace the lens unit and execute U411. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C3200
  • Description: CIS error Object: CIS model
  • Causes: • The white reference data retrieved by lighting the lamp at the initial operation is lower than the specified value. • The white reference data retrieved by lighting the lamp at the auto table adjustment is lower than the specified value.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the CIS lamp The CIS lamp does not light Check if the CIS lamp turns on. If not, replace the lamp unit and execute U411 [Table] 3 Checking the connection The FFC is not correctly connected. Clean the FFC terminals of the following FFC and reconnect them. If the FFC terminal is deformed or broken, replace the FFC. • CIS PWB — Main PWB (YC3001) 4 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C3300
  • Description: CCD AGC error Object: LED model For internal count
  • Causes: The white reference data after adjustment is not within the target range
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Cleaning the backside of the contact glass The white reference sheet is dirty. Clean the white reference sheet at the backside of the contact glass. 3 Checking the LED lamp The LED lamp is broken. Check if the LED lamp lights. If it does not light, replace the lamp unit and execute U411 [Table]. 4 Checking the connection The FFC is not correctly connected. Clean the FFC terminals of the following FFC and reconnect them. If the FFC terminal is deformed or broken, replace the FFC. • LED drive PWB — Main PWB (YC3003) 5 Checking the lens unit The CCD PWB is faulty. Clean the FFC terminal and reconnect it. If deformed or broken, replace the FFC. • CCD PWB — Main PWB (YC3002) If not repaired, replace the lens unit and execute U411. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C3300
  • Description: CIS AGC error Object: CIS model For internal count
  • Causes: The white reference data after adjustment is not within the target range
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Cleaning the backside of the contact glass The white reference sheet is dirty. Clean the white reference sheet at the backside of the contact glass. 3 Checking the CIS lamp The CIS lamp does not light Check if the CIS lamp turns on. If not, replace the lamp unit and execute U411 [Table] 4 Checking the connection The FFC is not correctly connected. Clean the FFC terminals of the following FFC and reconnect them. If the FFC terminal is deformed or broken, replace the FFC. • CIS PWB — Main PWB (YC3001) 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C3500
  • Description: Scanner AISC communication error
  • Causes: Readback values are different 4 times continuously during communication between the scanner and ASIC
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the main firmware and the engine firmware to the latest version. 2 Checking the connection FFC is not connected properly. Or it is faulty. Clean the FFC terminals of the following FFC and reconnect them. If the FFC terminal is deformed or broken, replace the FFC. • Main PWB (YC26) — Engine PWB (YC3) 3 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. 4 Replacing the main PWB The main PWB is faulty. Replace the main PWB.
  • Code: C3600
  • Description: Scanner sequence error
  • Causes: • Mail box buffer overflow is detected. • Software sequence error is detected.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the main firmware and the engine firmware to the latest version. 2 Executing U021 The memory operation is faulty. Execute U021 and initialize the backup data 3 Checking the connection FFC is not connected properly. Or it is faulty. Clean the FFC terminals of the following FFC and reconnect them. If the FFC terminal is deformed or broken, replace the FFC. • Main PWB (YC26) — Engine PWB (YC3) 4 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. 5 Replacing the main PWB The main PWB is faulty. Replace the main PWB.
  • Code: C4001
  • Description: Polygon motor K startup error
  • Causes: Polygon motor K is not in the steady state within 10s after becoming steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Polygon motor K — LSU relay PWB (YC5) • LSU relay PWB (YC9) — Engine PWB (YC6) 3 Checking the polygon motor The polygon motor does not rotate properly. Check the rotation sound of the polygon motor, and reattach or replace LSU K if it does not rotate properly. 4 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C4002
  • Description: Polygon motor C startup error
  • Causes: Polygon motor C is not in the steady state within 10s after becoming steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Polygon motor C — LSU relay PWB (YC7) • LSU relay PWB (YC9) — Engine PWB (YC6) 3 Checking the polygon motor The polygon motor does not rotate properly. Check the rotation sound of the polygon motor, and reattach or replace LSU C if it does not rotate properly. 4 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C4003
  • Description: Polygon motor M startup error
  • Causes: Polygon motor M is not in the steady state within 10s after becoming steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Polygon motor M — LSU relay PWB (YC6) • LSU relay PWB (YC9) — Engine PWB (YC6) 3 Checking the polygon motor The polygon motor does not rotate properly. Check the rotation sound of the polygon motor, and reattach or replace LSU M if it does not rotate properly. 4 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C4004
  • Description: Polygon motor Y startup error
  • Causes: Polygon motor Y is not in the steady state within 10s after becoming steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Polygon motor Y — LSU relay PWB (YC8) • LSU relay PWB (YC9) — Engine PWB (YC6) 3 Checking the polygon motor The polygon motor does not rotate properly. Check the rotation sound of the polygon motor, and reattach or replace LSU Y if it does not rotate properly. 4 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C4011
  • Description: Polygon motor K steady-state error
  • Causes: Polygon motor K is off from the steady state for 1s continuously after becoming the steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Polygon motor K — LSU relay PWB (YC5) • LSU relay PWB (YC9) — Engine PWB (YC6) 3 Checking the polygon motor The polygon motor does not rotate properly. Check the rotation sound of the polygon motor, and reattach or replace LSU K if it does not rotate properly. 4 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C4012
  • Description: Polygon motor C steady-state error
  • Causes: Polygon motor C is off from the steady state for 1s continuously after becoming the steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Polygon motor C — LSU relay PWB (YC7) • LSU relay PWB (YC9) — Engine PWB (YC6) 3 Checking the polygon motor The polygon motor does not rotate properly. Check the rotation sound of the polygon motor, and reattach or replace LSU C if it does not rotate properly. 4 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C4013
  • Description: Polygon motor M steady-state error
  • Causes: Polygon motor M is off from the steady state for 1s continuously after becoming the steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Polygon motor M — LSU relay PWB (YC6) • LSU relay PWB (YC9) — Engine PWB (YC6) 3 Checking the polygon motor The polygon motor does not rotate properly. Check the rotation sound of the polygon motor, and reattach or replace LSU M if it does not rotate properly. 4 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C4014
  • Description: Polygon motor Y steady-state error
  • Causes: Polygon motor Y is off from the steady state for 1s continuously after becoming the steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Polygon motor Y — LSU relay PWB (YC8) • LSU relay PWB (YC9) — Engine PWB (YC6) 3 Checking the polygon motor The polygon motor does not rotate properly. Check the rotation sound of the polygon motor, and reattach or replace LSU Y if it does not rotate properly. 4 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C4101
  • Description: BD initialization error (Black)
  • Causes: BD is not detected within 1s after polygon motor K is in the steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the main firmware to the latest version. 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • APC PWB K — LSU relay PWB (YC1) • LSU relay PWB (YC10) — Main PWB (YC23) 3 Checking the LSU The APC PWB does not operate normally Reinstall or replace LSU K. 4 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 5 Replacing the main PWB The main PWB is faulty. Replace the main PWB.
  • Code: C4102
  • Description: BD initialization error (Cyan)
  • Causes: BD is not detected within 1s after polygon motor C is in the steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the main firmware to the latest version. 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • APC PWB C — LSU relay PWB (YC3) • LSU relay PWB (YC10) — Main PWB (YC23) 3 Checking the LSU The APC PWB does not operate normally Reinstall or replace LSU C. 4 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 5 Replacing the main PWB The main PWB is faulty. Replace the main PWB.
  • Code: C4103
  • Description: BD initialization error (Magenta)
  • Causes: BD is not detected within 1s after polygon motor M is in the steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the main firmware to the latest version. 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • APC PWB M — LSU relay PWB (YC2) • LSU relay PWB (YC10) — Main PWB (YC23) 3 Checking the LSU The APC PWB does not operate normally Reinstall or replace LSU M. 4 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 5 Replacing the main PWB The main PWB is faulty. Replace the main PWB.
  • Code: C4104
  • Description: BD initialization error (Yellow)
  • Causes: BD is not detected within 1s after polygon motor Y is in the steady state.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the main firmware to the latest version. 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • APC PWB Y — LSU relay PWB (YC4) • LSU relay PWB (YC10) — Main PWB (YC23) 3 Checking the LSU The APC PWB does not operate normally Reinstall or replace LSU Y. 4 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 5 Replacing the main PWB The main PWB is faulty. Replace the main PWB.
  • Code: C4600
  • Description: LSU cleaning motor error
  • Causes: The error signal is detected for 2s continuously after the motor starts up.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the drive parts The drive transmission from the LSU cleaning motor is faulty. Repair the drive transmission parts if the drive from the LSU cleaning motor is not transmitted. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • LSU cleaning motor — LSU relay PWB (YC11) • LSU relay PWB (YC9) — Engine PWB (YC6) 4 Replacing the LSU cleaning motor The LSU cleaning motor is faulty. Replace the LSU cleaning motor. 5 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C4700
  • Description: Video ASIC device error
  • Causes: Writing data and reading data does not match 8 consecutive times.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the main firmware and engine firmware to the latest version. 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Main PWB (YC26) — Engine PWB (YC3) 3 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. 4 Replacing the main PWB The main PWB is faulty. Replace the main PWB.
  • Code: C6000
  • Description: IH heating error
  • Causes: 1. The fuser center thermistor does not detect 100°C / 212°F or more within 25s after warm-up is started. 2. During the warm-up, the fuser center thermistor does not detect the ready temperature within 20s after it detects 100°C / 212°F.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Executing U169 The IH setting mismatches the power supply specification. Set the destination same as the voltage of the IH PWB at U169. 3 Removing foreign material There are foreign objects between the fuser unit and the IH unit. Or, the foreign objects are adhered on the fuser heat belt. Remove foreign material if it is on between the fuser unit and the IH unit, or on the fuser unit. Then, reinstall the fuser unit. 4 Reinstalling the fuser unit There are foreign objects in the drawer contact terminal of the fuser unit Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected. 5 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit — Engine PWB (YC9) • IH unit — IH PWB (YC2, YC3) • IH PWB (YC4) — Engine PWB (YC10) 6 Replacing the fuser unit The parts such as the thermistor or thermal cutout are faulty. Replace the fuser unit. 7 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. 8 Replacing the IH PWB The IH PWB is faulty. Replace the IH PWB. 9 Replacing the IH unit The IH unit is faulty. Replace the IH unit.
  • Code: C6020
  • Description: Fuser center thermistor high temperature error
  • Causes: The fuser center thermistor detected 230°C / 446°F or more for 1s.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Reinstalling the fuser unit There are foreign objects in the drawer contact terminal of the fuser unit Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit — Engine PWB (YC9) • IH unit — IH PWB (YC2, YC3) • IH PWB (YC4) — Engine PWB (YC10) 4 Replacing the fuser unit The parts such as the thermistor are faulty. Replace the fuser unit. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. 6 Replacing the IH PWB The IH PWB is faulty. Replace the IH PWB. 7 Replacing the IH unit The IH unit is faulty. Replace the IH unit.
  • Code: C6030
  • Description: Broken fuser center thermistor
  • Causes: 1. During warm-up, the fuser center thermistor detects 41°C / 105°F for 1s continuously while the fuser edge thermistor detects 100°C / 212°F or more. 2. The fuser center thermistor does not detect 25°C / 77°F within 12s after start-up.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Removing foreign material There are foreign objects between the fuser unit and the IH unit. Or, the foreign objects are adhered on the fuser heat belt. Remove foreign material if it is on between the fuser unit and the IH unit, or on the fuser unit. Then, reinstall the fuser unit. 3 Reinstalling the fuser unit There are foreign objects in the drawer contact terminal of the fuser unit Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected. 4 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit — Engine PWB (YC9) • IH unit — IH PWB (YC2, YC3) • IH PWB (YC4) — Engine PWB (YC10) 5 Replacing the fuser unit The parts such as the thermistor are faulty. Replace the fuser unit. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. 7 Replacing the IH PWB The IH PWB is faulty. Replace the IH PWB. 8 Replacing the IH unit The IH unit is faulty. Replace the IH unit.
  • Code: C6050
  • Description: Fuser center thermistor low temperature error
  • Causes: The fuser center thermistor detects less than 80°C / 176°F for 1s during printing.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Removing foreign material There are foreign objects between the fuser unit and the IH unit. Or, the foreign objects are adhered on the fuser heat belt. Remove foreign material if it is on between the fuser unit and the IH unit, or on the fuser unit. Then, reinstall the fuser unit. 3 Reinstalling the fuser unit There are foreign objects in the drawer contact terminal of the fuser unit Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected. 4 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit — Engine PWB (YC9) • IH unit — IH PWB (YC2, YC3) • IH PWB (YC4) — Engine PWB (YC10) 5 Replacing the fuser unit The parts such as the thermistor are faulty. Replace the fuser unit. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. 7 Replacing the IH PWB The IH PWB is faulty. Replace the IH PWB. 8 Replacing the IH unit The IH unit is faulty. Replace the IH unit.
  • Code: C6120
  • Description: Fuser press roller thermistor high temperature error
  • Causes: The fuser press roller thermistor detected 210°C / 410°F or more for 1s.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Reinstalling the fuser unit There are foreign objects in the drawer contact terminal of the fuser unit Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit — Engine PWB (YC9) 4 Replacing the fuser unit The parts such as the thermistor are faulty. Replace the fuser unit. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C6130
  • Description: Broken fuser press roller thermistor
  • Causes: 1. During warm-up, the fuser press roller thermistor detects less than 35°C / 95°F for 60s continuously. 2. After finishing warm-up, the fuser press roller thermistor detects less than 35°C / 95°F for 30s continuously.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Removing foreign material There are foreign objects between the fuser unit and the IH unit. Or, the foreign objects are adhered on the fuser heat belt. Remove foreign material if it is on between the fuser unit and the IH unit, or on the fuser unit. Then, reinstall the fuser unit. 3 Reinstalling the fuser unit There are foreign objects in the drawer contact terminal of the fuser unit Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected. 4 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit — Engine PWB (YC9) • IH unit — IH PWB (YC2, YC3) • IH PWB (YC4) — Engine PWB (YC10) 5 Replacing the fuser unit The parts such as the thermistor are faulty. Replace the fuser unit. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. 7 Replacing the IH PWB The IH PWB is faulty. Replace the IH PWB. 8 Replacing the IH unit The IH unit is faulty. Replace the IH unit.
  • Code: C6200
  • Description: IH heating error 2
  • Causes: 1. After warm-up is started, the fuser edge thermistor does not detect 80°C / 176°F within 25s. Or, during the warm-up, specified temperature (Ready display temperature) is not detected even 420s passed after center thermistor reached 100°C / 212°F.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Removing foreign material There are foreign objects between the fuser unit and the IH unit. Or, the foreign objects are adhered on the fuser heat belt. Remove foreign material if it is on between the fuser unit and the IH unit, or on the fuser unit. Then, reinstall the fuser unit. 3 Reinstalling the fuser unit There are foreign objects in the drawer contact terminal of the fuser unit Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected. 4 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit — Engine PWB (YC9) • IH unit — IH PWB (YC2, YC3) • IH PWB (YC4) — Engine PWB (YC10) 5 Replacing the fuser unit The parts such as the thermistor are faulty. Replace the fuser unit. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. 7 Replacing the IH PWB The IH PWB is faulty. Replace the IH PWB. 8 Replacing the IH unit The IH unit is faulty. Replace the IH unit.
  • Code: C6220
  • Description: Fuser edge thermistor high temperature error
  • Causes: The fuser edge thermistor detects 245°C / 473°F or more for 1s.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Reinstalling the fuser unit There are foreign objects in the drawer contact terminal of the fuser unit Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit — Engine PWB (YC9) 4 Replacing the fuser unit The parts such as the thermistor are faulty. Replace the fuser unit. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. 6 Replacing the IH unit The IH unit is faulty. Replace the IH unit.
  • Code: C6230
  • Description: Broken fuser edge thermistor
  • Causes: 1. During warm-up, the fuser edge thermistor detects less than 41°C / 105°F for 1s continuously while the fuser center thermistor detects 100°C / 212°F or more. 2. The fuser edge thermistor does not detect 25°C / 77°F within 12s after start-up.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Reinstalling the fuser unit There are foreign objects in the drawer contact terminal of the fuser unit Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit — Engine PWB (YC9) 4 Replacing the fuser unit The parts such as the thermistor are faulty. Replace the fuser unit. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C6250
  • Description: Fuser edge thermistor low temperature error
  • Causes: The fuser edge thermistor detected less than 80°C / 176°F for 1s during printing.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Removing foreign material There are foreign objects between the fuser unit and the IH unit. Or, the foreign objects are adhered on the fuser heat belt. Remove foreign material if it is on between the fuser unit and the IH unit, or on the fuser unit. Then, reinstall the fuser unit. 3 Reinstalling the fuser unit There are foreign objects in the drawer contact terminal of the fuser unit Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected. 4 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit — Engine PWB (YC9) • IH unit — IH PWB (YC2, YC3) • IH PWB (YC4) — Engine PWB (YC10) 5 Replacing the fuser unit The parts such as the thermistor are faulty. Replace the fuser unit. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. 7 Replacing the IH PWB The IH PWB is faulty. Replace the IH PWB. 8 Replacing the IH unit The IH unit is faulty. Replace the IH unit.
  • Code: C6320
  • Description: Fuser middle thermistor high temperature error
  • Causes: The fuser middle thermistor detected 245°C / 473°F or more for 1s.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Reinstalling the fuser unit There are foreign objects in the drawer contact terminal of the fuser unit Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit — Engine PWB (YC9) 4 Replacing the fuser unit The parts such as the thermistor are faulty. Replace the fuser unit. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. 6 Replacing the IH unit The IH unit is faulty. Replace the IH unit.
  • Code: C6330
  • Description: Broken fuser middle thermistor
  • Causes: The fuser middle thermistor detects less than 41 °C / 105°F for 1s continuously while the fuser center thermistor or the fuser edge thermistor detects 100°C / 212°F or more during warm-up.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Reinstalling the fuser unit There are foreign objects in the drawer contact terminal of the fuser unit Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit — Engine PWB (YC9) 4 Replacing the fuser unit The parts such as the thermistor are faulty. Replace the fuser unit. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. 6 Replacing the IH unit The IH unit is faulty. Replace the IH unit.
  • Code: C6600
  • Description: Fuser heat belt rotation error
  • Causes: The belt rotation pulse is not input for 1.8s continuously.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Reinstalling the fuser unit There are foreign objects in the drawer contact terminal of the fuser unit Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit — Engine PWB (YC9) 4 Replacing the fuser unit The fuser unit parts such as the fuser heat belt, the belt rotation detecting system, or the belt rotation sensor are faulty Replace the fuser unit. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. 6 Replacing the fuser drive unit The fuser drive unit is faulty. Replace the fuser drive unit. Step
  • Code: C6610
  • Description: Fuser pressure release sensor error
  • Causes: 1. The fuser pressure release sensor does not turn off even after 10s passed from instructing to reduce the fuser pressure. 2. The fuser pressure release sensor does not turn on even after 10s passed from instructing to increase the fuser pressure. 3. The lock signal of the fuser pressure release motor became error for 300ms.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Reinstalling the fuser unit There are foreign objects in the drawer contact terminal of the fuser unit Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Drawer connector of the fuser unit — Engine PWB (YC9) 4 Replacing the fuser unit The fuser unit is faulty at the fuser pressure release mechanism or the fuser pressure release sensor . Replace the fuser unit. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C6740
  • Description: IH PWB high temperature error (IGBT2)
  • Causes: The IGBT temperature acquired from the power microprocessor detects 115°C / 239°F or more for 1s continuously.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • IH fan motor — Engine PWB (YC20) • IH PWB (YC4) — Engine PWB (YC10) 3 Replacing the IH PWB fan motor The IH PWB fan motor is faulty. Replace the IH PWB fan motor. 4 Replacing the IH PWB The IH PWB is faulty. Replace the IH PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C6760
  • Description: Fuser IH input excessive electric current error
  • Causes: The input current obtained from the power microcomputer was 20A (100/120V) or 10A (200V) or more continued for 200ms.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the fuser unit The fuser heat belt is faulty. Detach the fuser unit and check if the fuser heat belt is not faulty. If there is any damage, replace the fuser unit. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • IH PWB (YC4) — Engine PWB (YC10) 4 Replacing the IH PWB The IH PWB is faulty. Replace the IH PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C6770
  • Description: IH low power error
  • Causes: After fuser heating starts,the electric power detection on the IH PWB detected a set electric power value of 30% or less for a predetermined time.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Reinstalling the fuser unit There are foreign objects in the drawer contact terminal of the fuser unit Clean the drawer connector terminal of the fuser unit. Check if the pin of the drawer connector is not bent, and replace the fuser unit if it is bent. If it is normal, reinstall the fuser unit so that the drawer connector is securely connected. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • IH unit — IH PWB (YC2, YC3) • IH PWB (YC4) — Engine PWB (YC10) 4 Replacing the IH unit The IH unit is faulty. (The coil is broken.) Replace the IH unit. 5 Replacing the IH PWB The IH PWB is faulty. Replace the IH PWB. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C6940
  • Description: IH fan motor error
  • Causes: Lock-up is detected for 20s continuously when the fan motor drives.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • IH fan motor — Engine PWB (YC20) 3 Checking the IH fan motor The IH fan motors do not properly operate. Clean the IH fan motor and remove foreign objects. If not resolved after that, replace the IH fan motor. 4 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C6950
  • Description: IH-CPU communication error
  • Causes: 1. Communication between the IH PWB and the engine PWB is not established in the initial communication. (150ms interval x 10 times retries and then 3 times retries of the relay remote) 2. After the initial communication is established, communication between the IH PWB and the engine PWB is not established at the operation except for printing. (If communication fails for 500ms, 3 times retries or the relay remote are performed.) 3. After the initial communication is established, communication between the IH PWB and the engine PWB is not established durint printing. (If communication fails for 500ms, 150ms interval x 10 times retries are performed.)
  • Remedy: 1 Resetting the main power The power startup delays. Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • IH PWB (YC4) — Engine PWB (YC10) 4 Replacing the IH PWB The IH PWB is faulty. Replace the IH PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C6990
  • Description: Fuser power source destination error
  • Causes: The engine backup data does not match the IH PWB power supply destination. (0, 5 or more)
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Executing U169 The voltage setting at U169 mismatches the voltage of the IH PWB. Set the destination same as the voltage of the IH PWB at U169. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • IH PWB (YC4) — Engine PWB (YC10) 4 Replacing the IH PWB The IH PWB is faulty. Replace the IH PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7101
  • Description: T/C sensor K error
  • Causes: The sensor input voltage is less than 0.3V, or 3.2V or more. Also, that state continues for 5s or more.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Reinstalling the developer unit The developer unit is not properly installed. Reinstall developer unit K so that the connector firmly connects. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Developer PWB K — Drum/Developer relay PWB (YC9) • Drum/Developer relay PWB (YC1) — Engine PWB (YC17) 4 Developer unit replacement Developer unit K (T/C sensor K) is faulty. Replace developer unit K. 5 Replacing the drum/developer relay PWB The drum/developer relay PWB is faulty. Replace the drum/developer relay PWB. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7102
  • Description: T/C sensor C error
  • Causes: The sensor input voltage is less than 0.3V, or 3.2V or more. Also, that state continues for 5s or more.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Reinstalling the developer unit The developer unit is not properly installed. Reinstall developer unit C so that the connector firmly connects. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Developer PWB C — Drum/Developer relay PWB (YC7) • Drum/Developer relay PWB (YC1) — Engine PWB (YC17) 4 Developer unit replacement Developer unit C (T/C sensor C) is faulty. Replace the developer unit C. 5 Replacing the drum/developer relay PWB The drum/developer relay PWB is faulty. Replace the drum/developer relay PWB. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7103
  • Description: T/C sensor M error
  • Causes: The sensor input voltage is less than 0.3V, or 3.2V or more. Also, that state continues for 5s or more.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Reinstalling the developer unit The developer unit is not properly installed. Reinstall developer unit M so that the connector firmly connects. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Developer PWB M — Drum/Developer relay PWB (YC8) • Drum/Developer relay PWB (YC1) — Engine PWB (YC17) 4 Developer unit replacement Developer unit M (T/C sensor M) is faulty. Replace the developer unit M. 5 Replacing the drum/developer relay PWB The drum/developer relay PWB is faulty. Replace the drum/developer relay PWB. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7104
  • Description: T/C sensor Y error
  • Causes: The sensor input voltage is less than 0.3V, or 3.2V or more. Also, that state continues for 5s or more.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Reinstalling the developer unit The developer unit is not properly installed. Reinstall developer unit Y so that the connector firmly connects. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Developer PWB Y — Drum/Developer relay PWB (YC6) • Drum/Developer relay PWB (YC1) — Engine PWB (YC17) 4 Developer unit replacement Developer unit Y (T/C sensor Y) is faulty. Replace the developer unit Y. 5 Replacing the drum/developer relay PWB The drum/developer relay PWB is faulty. Replace the drum/developer relay PWB. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7200
  • Description: Inner thermistor broken (developer)
  • Causes: The sensor input data is 0.3V or less.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Reinstalling the developer unit The developer unit is not properly installed. Reinstall developer unit K so that the connector firmly connects. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Developer PWB K — Drum/Developer relay PWB (YC9) • Drum/Developer relay PWB (YC1) — Engine PWB (YC17) 4 Developer unit replacement The sensor on the developer PWB is faulty Replace developer unit K. 5 Replacing the drum/developer relay PWB The drum/developer relay PWB is faulty. Replace the drum/developer relay PWB. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7210
  • Description: Inner thermistor short-circuited (developer)
  • Causes: The sensor input data is 3.0V or more.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Reinstalling the developer unit The developer unit is not properly installed. Reinstall developer unit K so that the connector firmly connects. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Developer PWB K — Drum/Developer relay PWB (YC9) • Drum/Developer relay PWB (YC1) — Engine PWB (YC17) 4 Developer unit replacement The sensor on the developer PWB is faulty Replace developer unit K. 5 Replacing the drum/developer relay PWB The drum/developer relay PWB is faulty. Replace the drum/developer relay PWB. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7221
  • Description: Broken LSU thermistor K
  • Causes: The sensor input data is 0.3V or less.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector or FFC is not properly connected, or the wire or FFC is faulty. Clean the terminal of the following wire connectors and the FFC, then reinsert them. If there is no continuity, replace the wire or FFC. • APC PWB K — LSU relay PWB (YC1) • LSU relay PWB (YC9) — Engine PWB(YC6) 3 Replacing the LSU LSU thermistor K is faulty. Replace LSU K. 4 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7224
  • Description: Broken LSU thermistor Y
  • Causes: The sensor input data is 0.3V or less.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector or FFC is not properly connected, or the wire or FFC is faulty. Clean the terminal of the following wire connectors and the FFC, then reinsert them. If there is no continuity, replace the wire or FFC. • APC PWB Y — LSU relay PWB (YC4) • LSU relay PWB (YC9) — Engine PWB(YC6) 3 Replacing the LSU LSU thermistor Y is faulty. Replace LSU Y. 4 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7231
  • Description: LSU thermistor K short-circuited
  • Causes: The sensor input data is 3.0V or more.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector or FFC is not properly connected, or the wire or FFC is faulty. Clean the terminal of the following wire connectors and the FFC, then reinsert them. If there is no continuity, replace the wire or FFC. • APC PWB K — LSU relay PWB (YC1) • LSU relay PWB (YC9) — Engine PWB(YC6) 3 Replacing the LSU LSU thermistor K is faulty. Replace LSU K. 4 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7234
  • Description: LSU thermistor Y short-circuited
  • Causes: The sensor input data is 3.0V or more.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector or FFC is not properly connected, or the wire or FFC is faulty. Clean the terminal of the following wire connectors and the FFC, then reinsert them. If there is no continuity, replace the wire or FFC. • APC PWB Y — LSU relay PWB (YC4) • LSU relay PWB (YC9) — Engine PWB(YC6) 3 Replacing the LSU LSU thermistor Y is faulty. Replace LSU Y. 4 Replacing the LSU relay PWB The LSU relay PWB is faulty. Replace the LSU relay PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7240
  • Description: Broken container thermistor
  • Causes: The sensor input data is 0.3V or less.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Container relay PWB (YC1) — Engine PWB (YC22) 3 Replacing the container relay PWB The container relay PWB is faulty. Replace the container relay PWB. 4 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7250
  • Description: Container thermistor short-circuited
  • Causes: The sensor input data is 3.0V or more.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Container relay PWB (YC1) — Engine PWB (YC22) 3 Replacing the container relay PWB The container relay PWB is faulty. Replace the container relay PWB.
  • Code: C7601
  • Description: Front ID sensor error
  • Causes: • The sensor output value of the dark potential is 0.15V or less, or 0.80V or more. • Bright potential is lower than the dark potential, or the gap is 0.5V or less.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Cleaning the front ID sensor The front ID sensor is dirty. Clean the front ID sensor surface. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Front ID sensor — Engine PWB (YC7) 3 Replacing the front D sensor The front ID sensor is faulty. Replace the front ID sensor. 4 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7602
  • Description: Rear ID sensor error
  • Causes: • The sensor output value of the dark potential is 0.15V or less, or 0.80V or more. • Bright potential is lower than the dark potential, or the gap is 0.5V or less.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Cleaning the rear ID sensor The rear ID sensor is dirty. Clean the rear ID sensor surface. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Rear ID sensor — Engine PWB (YC7) 3 Replacing the rear ID sensor The rear ID sensor is faulty. Replace the rear ID sensor. 4 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7611
  • Description: ID sensor density error K
  • Causes: The density of the BK-patch on the primary transfer belt is faulty at the Calibration or Color Adjustment.
  • Remedy: 1 Resetting the main power The ID sensor does not operate properly. Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 3 Cleaning the ID sensor The ID sensor is dirty. Clean the surface of the front and rear ID sensors. 4 Checking the developer unit and drum unit The developer unit or the drum unit is not properly installed. Reinstall developer unit K and drum unit K. 5 Checking the primary transfer unit The primary transfer belt is dirty. Clean the surface of the primary transfer belt, or replace the primary transfer unit. 6 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Front ID sensor and Rear ID sensor — Engine PWB (YC7) 7 Replacing the ID sensor The ID sensor is faulty. Replace the front ID sensor or the rear ID sensor. 8 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7612
  • Description: ID sensor density error C
  • Causes: The density of the C-patch on the primary transfer belt is faulty at the Calibration or Color Adjustment.
  • Remedy: 1 Resetting the main power The ID sensor does not operate properly. Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 3 Cleaning the ID sensor The ID sensor is dirty. Clean the surface of the front and rear ID sensors. 4 Checking the developer unit and drum unit The developer unit or the drum unit is not properly installed. Reinstall developer unit C and drum unit C. 5 Checking the primary transfer unit The primary transfer belt is dirty. Clean the surface of the primary transfer belt, or replace the primary transfer unit. 6 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Front ID sensor and Rear ID sensor — Engine PWB (YC7) 7 Replacing the ID sensor The ID sensor is faulty. Replace the front ID sensor or the rear ID sensor. 8 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7613
  • Description: ID sensor density error M
  • Causes: The density of the M-patch on the primary transfer belt is faulty at the Calibration or Color Adjustment.
  • Remedy: 1 Resetting the main power The ID sensor does not operate properly. Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 3 Cleaning the ID sensor The ID sensor is dirty. Clean the surface of the front and rear ID sensors. 4 Checking the developer unit and drum unit The developer unit or the drum unit is not properly installed. Reinstall developer unit M and drum unit M. 5 Checking the primary transfer unit The primary transfer belt is dirty. Clean the surface of the primary transfer belt, or replace the primary transfer unit. 6 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Front ID sensor and Rear ID sensor — Engine PWB (YC7) 7 Replacing the ID sensor The ID sensor is faulty. Replace the front ID sensor or the rear ID sensor. 8 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7614
  • Description: ID sensor density error Y
  • Causes: The density of the Y-patch on the primary transfer belt is faulty at the Calibration or Color Adjustment.
  • Remedy: 1 Resetting the main power The ID sensor does not operate properly. Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 3 Cleaning the ID sensor The ID sensor is dirty. Clean the surface of the front and rear ID sensors. 4 Checking the developer unit and drum unit The developer unit or the drum unit is not properly installed. Reinstall developer unit Y and drum unit Y. 5 Checking the primary transfer unit The primary transfer belt is dirty. Clean the surface of the primary transfer belt, or replace the primary transfer unit. 6 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Front ID sensor and Rear ID sensor — Engine PWB (YC7) 7 Replacing the ID sensor The ID sensor is faulty. Replace the front ID sensor or the rear ID sensor. 8 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7620
  • Description: ID sensor timing error
  • Causes: The color registration fails.
  • Remedy: 1 Resetting the main power The ID sensor does not operate properly. Turn off the power switch and unplug the power plug. After 5s passes, reconnect the power plug and turn on the power switch. 2 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 3 Cleaning the ID sensor The ID sensor is dirty. Clean the surface of the front and rear ID sensors. 4 Checking the developer unit and drum unit The developer unit or the drum unit is not properly installed. Reinstall the developer unit and drum unit. 5 Checking the primary transfer unit The primary transfer belt is dirty. Clean the surface of the primary transfer belt, or replace the primary transfer unit. 6 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Front ID sensor and Rear ID sensor — Engine PWB (YC7) 7 Replacing the ID sensor The ID sensor is faulty. Replace the front ID sensor or the rear ID sensor. 8 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7800
  • Description: Outer thermistor broken
  • Causes: The sensor input data is 0.3V or less.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Temperature/humidity sensor — Engine PWB (YC11) 3 Replacing the temperature/ humidity sensor The temperature/humidity sensor is faulty. Replace the temperature/humidity sensor. 4 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C7810
  • Description: Outer thermistor short-circuited
  • Causes: The sensor input data is 3.0V or more.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Temperature/humidity sensor — Engine PWB (YC11) 3 Replacing the temperature/ humidity sensor The temperature/humidity sensor is faulty. Replace the temperature/humidity sensor. 4 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C8030
  • Description: DF tray upper limit detection error Object: 500-sheet document finisher
  • Causes: The DF tray upper limit sensor on is detected when the DF tray motor is in ascending operation
  • Remedy: 1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF tray upper limit sensor — DFPWB (CN5) • Paper level sensor 1, 2 — DFPWB (CN6) 2 Replacing the sensor The Dr tray upper limit sensor, paper level sensor 1 or 2 is faulty Replace the DF tray upper limit sensor or paper level sensor. 3 Firmware upgrade The firmware is not the latest version. Upgrade the DP firmware to the latest version. 4 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB.
  • Code: C8040
  • Description: DF belt error Object: 500-sheet document finisher
  • Causes: The DF belt sensor on or off cannot be detected when passing the specified time after the DF belt solenoid turns on
  • Remedy: 1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the wire connector terminal and reconnect it. If there is no continuity, replace the wire. • DF belt sensor — DF PWB (CN10) • DF belt solenoid — DF PWB (CN21) 2 Replacing the DF belt sensor DF belt sensor is faulty Replace DF belt sensor 3 Replacing the DF belt solenoid DF belt solenoid is faulty Replace DF belt solenoid 4 Firmware upgrade The firmware is not the latest version. Upgrade the DP firmware to the latest version. 5 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB.
  • Code: C8140
  • Description: Dr tray motor error Object: 500-sheet document finisher
  • Causes: During the DF tray motor drive, the DF tray lower limit sensor, paper level sensor 1 and 2 on is not detected within 10s.
  • Remedy: 1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF tray motor — DF PWB (CN15) • DF tray lower limit sensor — DF PWB (CN5) • Paper level sensor1, 2 — DF PWB (CN6) 2 Replacing the DF tray motor The DF tray motor is faulty. Replace the DF tray motor. 3 Replacing the sensor The DF tray lower limit sensor, paper level sensor 1 or 2 is faulty Replace the DF tray lower limit sensor or paper level sensor. 4 Firmware upgrade The firmware is not the latest version. Upgrade the DP firmware to the latest version. 5 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB.
  • Code: C8210
  • Description: DF staple error Object: 500-sheet document finisher
  • Causes: JAM7013 and 7023 was detected twice
  • Remedy: 1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF staple unit — DF PWB 2 Checking the staple Check if the upper BF registration guide shifts manually, and reattach it if it does not smoothly shift. Check if the lower BF registration guide shifts manually, and reattach it if it does not smoothly shift. 3 Replacing the DF staple unit The DF staple unit is faulty. Replace the DF staple unit. 4 Firmware upgrade The firmware is not the latest version. Upgrade the DP firmware to the latest version. 5 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB.
  • Code: C8320
  • Description: DF adjuster motor 2 error Object: 500-sheet document finisher
  • Causes: The DF adjustor sensor 2 on or off cannot be detected when passing the specified time after the DF adjustor motor 2 turns on
  • Remedy: 1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF adjustor motor 2 — DFPWB (CN18) • DF adjustor sensor 2 — DFPWB (CN7) 2 Replacing DF adjustor motor 2 DF adjustor motor 2 is faulty Replace DF adjustor motor 2 3 Replacing the DF adjustor sensor 2 DF adjustor sensor 2 is faulty Replace DF adjustor sensor 2 4 Firmware upgrade The firmware is not the latest version. Upgrade the DP firmware to the latest version. 5 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB.
  • Code: C8330
  • Description: DF adjuster motor 1error Object: 500-sheet document finisher
  • Causes: The DF adjustor sensor 1 on or off cannot be detected when passing the specified time after the DF adjustor motor 1 turns on
  • Remedy: 1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire.• DF adjustor motor 1 — DFPWB(CN18) • DF adjustor sensor 1 — DFPWB(CN7) 2 Replacing DF adjustor motor 1 DF adjustor motor 1 is faulty Replace DF adjustor motor 1 3 Replacing the DF adjustor sensor 1 DF adjustor sensor 1 is faulty Replace DF adjustor sensor 1 4 Firmware upgrade The firmware is not the latest version. Upgrade the DP firmware to the latest version. 5 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB.
  • Code: C8350
  • Description: DF roller motor error Object: 500-sheet document finisher
  • Causes: The DF roller sensor on or off cannot be detected when passing the specified time after the DF roller motor turns on
  • Remedy: 1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF roller motor — DF PWB (CN20) • DF roller sensor — DF PWB (CN11) 2 Replacing the DF roller sensor DF roller sensor is faulty Replace DF roller sensor 3 Replacing the DF roller motor The DF roller motor is faulty Replace DF roller motor 4 Firmware upgrade The firmware is not the latest version. Upgrade the DP firmware to the latest version. 5 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB.
  • Code: C8360
  • Description: DF slide motor error Object: 500-sheet document finisher
  • Causes: The DF slide sensor on or off cannot be detected when passing the specified time after the DF slide motor turns on
  • Remedy: 1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DF slide motor — DF PWB(CN14) • DF slide sensor — DF PWB(CN22) 2 Replacing the DF slide sensor The DF slide sensor is faulty. Replace the DF slide sensor 3 Replacing the DF slide motor The DF slide motor is faulty. Replace the DF slide motor 4 Firmware upgrade The firmware is not the latest version. Upgrade the DP firmware to the latest version. 5 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB.
  • Code: C8460
  • Description: EEPROM error Object: 500-sheet document finisher
  • Causes: EEPROM read/write is not available
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the DP firmware to the latest version. 2 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB.
  • Code: C8800
  • Description: Document finisher communication error Object: 500-sheet document finisher
  • Causes: The communication error was detected 10 times continuously.
  • Remedy: 1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the wire connector terminal and reconnect it. If there is no continuity, replace the wire. • Engine PWB (YC5) — DF relay PWB (YC2) • DF relay PWB (YC3) — DF PWB (CN1) 2 Firmware upgrade The firmware is not the latest version. Upgrade the DP firmware to the latest version. 3 Replacing the DF relay PWB The DF relay PWB is faulty Replace the DF relay PWB. 4 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. 5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C8830
  • Description: Relay conveying unit communication error Object: 500-sheet document finisher + relay conveying unit
  • Causes: The communication error was detected 10 times continuously.
  • Remedy: 1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Engine PWB (YC5) — DF relay PWB (YC2) • DF relay PWB (YC4) — BR PWB (YC5) 2 Firmware upgrade The firmware is not the latest version. Upgrade the BR firmware to the latest version. 3 Replacing the BR PWB The BR PWB is faulty. Replace the BR PWB. 4 Replacing the DF relay PWB The DF relay PWB is faulty Replace the DF relay PWB. 5 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C8990
  • Description: Finisher setup error Object: 500-sheet document finisher + relay conveying unit
  • Causes: 1. Communication error occurs with either the finisher or relay conveying unit. 2. Communication error occurs while installation of the relay conveying unit is detected
  • Remedy: 1 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the wire connector terminal and reconnect it. If there is no continuity, replace the wire. • DF PWB (CN1) — DF relay PWB (YC3) • DF relay PWB (YC4) — BR PWB (YC5) 2 Firmware upgrade The firmware is not the latest version. Upgrade the DP firmware to the latest version. 3 Replacing the DF PWB The DF PWB is faulty. Replace the DF PWB. 4 Replacing the BR PWB The BR PWB is faulty. Replace the BR PWB.
  • Code: C9000
  • Description: DP communication error Object: Document processor
  • Causes: The communication error was detected 10 times continuously.
  • Remedy: 1 Firmware upgrade The main unit firmware and the document processor firmware mismatch Upgrade the main unit firmware and the document processor firmware to the latest version. 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • DP PWB (YC2) — Engine PWB (YC4) 3 Replacing the DP PWB The DP PWB is faulty. Replace the DP PWB. 4 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: C9060
  • Description: DP EEPROM error Object: Document processor
  • Causes: The writing data and the reading data into the EEPROM mismatch.
  • Remedy: 1 Checking the EEPROM The EEPROM is not properly installed. Reattach the EEPROM on the DP PWB. 2 Replacing the DP PWB The DP PWB is faulty. Replace the DP PWB. 3 Replacing the EEPROM The EEPROM is faulty. Replace the EEPROM on the DP PWB, then execute U411.
  • Code: C9180
  • Description: DP feed-shift motor error Object: Document processor
  • Causes: 1. The DP feed-shift motor home position cannot be detected even driving it for one round. 2. The DP feed-shift motor home position cannot be detected even after retrying the detection for 3 times.
  • Remedy: 1 Checking the connection The EEPROM is not properly installed. Reattach the EEPROM on the DP PWB. 2 Replacing the DP feed-shift sensor Replace the DP feed-shift sensor 3 Replacing the DP feed-shift motor Replace the DP feed-shift motor 4 Replacing the DP PWB The DP PWB is faulty. Replace the DP PWB 5 Replacing the engine PWB The EEPROM is faulty. Replace the engine PWB
  • Code: F000
  • Description: Main unit CPU communication error (Controller — Panel)
  • Causes: The panel cannot be detected since the CPU communication between the main PWB and the operation panel main PWB is unavailable.
  • Remedy: 1 Resetting the main power The communication between the main PWB and the operation panel main PWB is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch. 2 Checking the connection The connector is not connected properly. Or, the wire or the SATA cable is faulty. Clean the wire, the terminal of SATA cable connector and reconnect them. If there is no continuity, replace the wire. • Main PWB — Operation panel PWB 3 Executing U021 The backup RAM data is faulty. Execute U021 to initialize the backup RAM data. 4 Replacing the main PWB The main PWB is faulty. Replace the main PWB. 5 Replacing the operation panel main PWB The operation panel main PWB is faulty. Replace the panel main PWB.
  • Code: F000
  • Description: CF000 will be displayed if * notes progress is carried out for a definite period of time with a Welcome screen.The communication fault between Panel-Main boards.Communication fault between Panel Core- Main Core Notes 2
  • Causes:
  • Remedy: 1) Check the harness of * (between Main board <=>SSD), and the connection state of a connector between Panel<=>Main boards, and perform an operation check. (2) Check contact of a DDR memory (extracting) and perform an operation check. If exchangeable, it will exchange and will perform an operation check. (3) Initialize SSD and perform an operation check. * (4) U021 Controller backup initialization is carried out and an operation check is performed. (5) Exchange a Main board and perform an operation check. (6) Exchange a PanelMain board and perform an operation check. (7) It will get, if USBLOG is obtainable, and contact service headquarters. * : only SSD standard model * Note 2 : Only Dual Core CPU model
  • Code: F010
  • Description: Program read error
  • Causes: Data corruption is detected at the program read
  • Remedy: 1 Resetting the main power The communication between the main PWB and the operation panel main PWB is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch. 2 Executing U021 The backup RAM data is faulty. Execute U021 to initialize the backup RAM data. 3 Replacing the main PWB The main PWB is faulty. Replace the main PWB.
  • Code: F020
  • Description: System memory error (RAM reading/writing error or CPU memory error)
  • Causes: The error appears during the reading/writing check of the RAM for the CPU when the main unit starts up.
  • Remedy: 1 Resetting the main power The communication between the main PWB and the operation panel main PWB is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch. 2 Executing U021 The backup RAM data is faulty. Execute U021 to initialize the backup RAM data. 3 Checking the main PWB The connector or the FFC is not connected properly. Or, the wire, FFC, the PWB is faulty. Clean the terminal of the connectors on the main PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace them. If not resolved, replace the main PWB.
  • Code: F040
  • Description: Communication error between the main unit CPU (Communication error between the controller and engine)
  • Causes: There is an error in the communication between the main PWB and the engine PWB.
  • Remedy: 1 Resetting the main power There is an error in the communication between the main PWB and the engine PWB. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch. 2 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the following wire connectors and reconnect the connectors. If there is no continuity, replace the wire. • Engine PWB (YC3) — Main PWB (YC26) 3 Firmware upgrade The firmware is not the latest version. Upgrade the main firmware and the engine firmware to the latest version. 4 Replacing the main PWB The main PWB is faulty. Replace the main PWB. 5 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB.
  • Code: F050
  • Description: Engine program error
  • Causes: The engine program cannot start up.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version 2 Resetting the main power The engine firmware checksum is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch. 3 Checking the EEPROM The EEPROM is not properly attached. Reattach the EEPROM. 4 Checking the engine PWB The connector or the FFC is not connected properly. Or, the wire, FFC, the PWB is faulty. Clean the terminal of the connectors on the engine PWB, reconnect the connector of the wire, and reconnect the FFC terminal. If the wire or the FFC is faulty, repair or replace it. If not resolved, replace the engine PWB.
  • Code: F052
  • Description: Panel engine program error
  • Causes: The panel program cannot start up.
  • Remedy: 1 Firmware upgrade The firmware is not the latest version. Upgrade the panel firmware to the latest version. 2 Resetting the main power The panel RAM checksum is faulty. Turn off the power switch and pull out the power plug. After passing 5s, reinsert the power plug and turn on the power switch. 3 Checking the connection The connector is not connected properly, or the wire is faulty. Clean the terminal of the connectors on the operation panel PWB, reconnect the connector of the wire. If there is no continuity, replace the wire. 4 Replacing the operation panel main PWB The operation panel main PWB is faulty. Replace the panel main PWB.
  • Code: F12X
  • Description: Abnormality detecting in a Scan control section
  • Causes:
  • Remedy: (1) Check the harness between Scan/DP<=>Main boards, and the connection state of a connector, and perform an operation check. (2) Initialize HDD and perform an operation check. * (3) U021 Controller backup initialization is carried out and an operation check is performed. (4) Exchange a Scan/DP board and perform an operation check. (5) Exchange a Main board and perform an operation check. (6) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F14X
  • Description: Abnormality detecting in a FAX control part
  • Causes:
  • Remedy: (1) Check the harness between FAX<=>Main boards, and the connection state of a connector, and perform an operation check. (2) Initialize SSD and perform an operation check. * (3) U021 Controller backup initialization is carried out and an operation check is performed. (4) Perform a deed operation check for DIMM Clear by U671. * Notes(Since it disappears when received data remain, cautions are required.) (5) Exchange FAX_DIMM and perform an operation check. * Notes (6) Exchange a FAX board and perform an operation check. (7) Exchange a Main board and perform an operation check. (8) Get USBLOG and contact service headquarters. * Only SSD standard model * Note Only model which has Flash for FAX data in a Main board
  • Code: F15X
  • Description: Abnormality detecting in an authentication device control section
  • Causes: Authentication device: Card reader etc.
  • Remedy: (1) Check the harness between authentication device <=>Main boards, and the connection situation of a connector, and perform an operation check. (2) Initialize SSD and perform an operation check. * (3) Carry out U021 Main backup initialization and perform an operation check. (4) Exchange a Main board and perform an operation check. (5) Exchange SSD and perform an operation check. * (6) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F17X
  • Description: Abnormality detecting in a printer data control part
  • Causes:
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F18X
  • Description: Abnormality detecting in a Video control section
  • Causes:
  • Remedy: (1) Check the harness between Engine<=>Main boards, and the connection state of a connector, and perform an operation check. (2) Initialize SSD and perform an operation check. * (3) U021 Controller backup initialization is carried out and an operation check is performed. (4) Exchange an Engine board and perform an operation check. (5) Exchange a Main board and perform an operation check. (6) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F1DX
  • Description: Abnormality detecting of the image memory Management Department
  • Causes: Poor arrangement of F1D4:Random Access Memory(1) Confirmation of U340(2) Initialization of a set point (U021)
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F21X, F22X, F23X
  • Description: Abnormality detecting in an image-processing part
  • Causes: F248 is the abnormalities of a printer process.In recurring by specific printer data, please give me cooperation at acquisition of capture data and USBLOG.
  • Remedy: (1) Check contact of a DDR memory and perform an operation check. (2) Initialize SSD and perform an operation check. * (3) Carry out U021 Main backup initialization and perform an operation check. (4) Exchange a Main board and perform an operation check. (5) Exchange SSD and perform an operation check. * (6) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F24X
  • Description: Abnormality detecting in the system Management Department
  • Causes: F248 is the abnormalities of a printer process.In recurring by specific printer data, please give me cooperation at acquisition of capture data and USBLOG.
  • Remedy: (1) Check contact of a DDR memory and perform an operation check. (2) Initialize SSD and perform an operation check. * (3) Carry out U021 Main backup initialization and perform an operation check. (4) Exchange a Main board and perform an operation check. (5) Exchange SSD and perform an operation check.* (6) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F25X
  • Description: Abnormality detecting in a network management department
  • Causes: It may occur according to a visitor’s network environment.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Get USBLOG and packet capture and contact service headquarters. * Only SSD standard model
  • Code: F26X … F2AX
  • Description: Abnormality detecting in the system Management Department
  • Causes:
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard mode
  • Code: F2BX … F32X
  • Description: Abnormality detecting in a network control part
  • Causes:
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. 4) Get USBLOG and contact service headquarters. (Depending on an analysis result, it is packet capture acquisition) * Only SSD standard model
  • Code: F33X
  • Description: Abnormality detecting in the Scan Management Department
  • Causes:
  • Remedy: (1) Check the harness between Scan/DP<=>Main boards, and the connection state of a connector, and perform an operation check. (2) Initialize SSD and perform an operation check. * (3) U021 Controller backup initialization is carried out and an operation check is performed. (4) Exchange a Scan/DP board and perform an operation check. (5) Exchange a Main board and perform an operation check. (6) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F34X
  • Description: Abnormality detecting in the Panel Management Department
  • Causes:
  • Remedy: (1) Check the harness between Panel<=>Main boards, and the connection state of a connector, and perform an operation check. * Notes (2) Initialize SSD and perform an operation check. * (3) U021 Controller backup initialization is carried out and an operation check is performed. (4) Exchange a Panel board and perform an operation check. * Notes (5) Exchange a Main board and perform an operation check. (6) Get USBLOG and contact service headquarters. * Only SSD standard model * Note : A Dual Core CPU model and HyPAS model
  • Code: F35X
  • Description: Abnormality detecting in the printing controlling Management Department
  • Causes:
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F37X
  • Description: Abnormality detecting in the FAX Management Department
  • Causes:
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Perform a deed operation check for DIMM Clear by U671.(Since it disappears when received data remain, cautions are required.) * notes (4) Exchange FAX_DIMM and perform an operation check. * Notes (5) Exchange a Main board and perform an operation check. (6) Exchange SSD and perform an operation check. * (7) Get USBLOG and contact service headquarters. * Only SSD standard model * Note Only model which has Flash for FAX data in a Main board
  • Code: F38X
  • Description: Abnormality detecting in the authentication authorized Management Department
  • Causes:
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F3AX … F45X
  • Description: Abnormality detecting in the Entity Management Department
  • Causes:
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F46X
  • Description: Abnormality detecting of a printer rendering part
  • Causes: F46F is the abnormalities of a printer process.In recurring by specific printer data, please give me cooperation at acquisition of capture data and USBLOG.
  • Remedy: (1) Exchange boards and perform an operation check. (2) the acquisition wish of USBLOG — carry out(Depending on the (2) case, it is print capture data acquisition) * Only SSD standard model
  • Code: F47X
  • Description: Abnormality detecting of an image editing processing part
  • Causes:
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F4DX
  • Description: Abnormality detecting in the Entity Management Department
  • Causes:
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F50X
  • Description: Abnormality detecting in the FAX Management Department
  • Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F52X … F57X
  • Description: Abnormality detecting in a JOB execution part
  • Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F63X
  • Description: Abnormality detecting in a device control section
  • Causes:
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F68X
  • Description: Abnormality detecting in a storage device control section
  • Causes: F684 is the overwrite error at the time of an SSD security kit.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F80X
  • Description: Abnormality detecting in the Data Access Platform Service
  • Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F90X
  • Description: Abnormality detecting in the extension application service part
  • Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F93X
  • Description: Abnormality detecting in the extension application management part
  • Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: F9FX
  • Description: Abnormality detecting in the extension application various service part
  • Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: FC0X
  • Description: Abnormality detecting in system application
  • Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: FC5X
  • Description: Abnormality detecting in Copy application
  • Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: FCAX
  • Description: Abnormality detecting in Print application
  • Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: FCFX
  • Description: Abnormality detecting in Send application
  • Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: FD4X
  • Description: Abnormality detecting in Box application
  • Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: FD9X
  • Description: Abnormality detecting in FAX application
  • Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: FE3X
  • Description: Abnormality detecting in a authentication/ authorization part
  • Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: FF5X
  • Description: Abnormality detecting in the Application Entity Management Department
  • Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard model
  • Code: FF7X
  • Description: Abnormality detecting in a report creation part
  • Causes: Since the USB log immediately after occurrence is needed for analysis, please give me cooperation of acquisition.
  • Remedy: (1) Initialize SSD and perform an operation check. * (2) Carry out U021 Main backup initialization and perform an operation check. (3) Exchange a Main board and perform an operation check. (4) Exchange SSD and perform an operation check. * (5) Get USBLOG and contact service headquarters. * Only SSD standard mode

Чем мы можем вам сегодня помочь?



Изменено: Чт, 12 Июл, 2018 at 3:35 PM


В машинах Kyocera P6021cdn, P6026cdn, M6026cdn/cidn, M6526cdn/cidn, FSC5150/5250/5350 и многих других довольно часто приходится сталкиваться с ошибкам C7401, C7402, C7403, C7404.

Описание этих ошибок в сервисной документации такое: «Developing unit non-installing error».  Суть ошибок — машина не «видит» сигнала с датчика концентрации тонера в блоке проявки (7401 –Black, 7402 – Cyan, 7403 – Magenta, 7404 – Yellow). 

Т.е. показания датчика выходят за допустимый диапазон, что может быть вызвано чрезмерно низкой концентрацией тонера в девелопере или недостаточным количеством девелопера в блоке проявки. Предлагаемый сервисной документацией способ устранения проблемы обычно заканчивается весьма дорогим пунктом — заменой блоков проявки целиком.

Частые причины появления проблемы – использование «не очень совместимого» тонера или использование машины не по своему назначению. Машины предназначены для офисной печати в нормальных условиях, и не очень хорошо справляются с печатью при высоком или низком заполнении тонером напечатанных страниц, а также в условиях высокой или низкой влажности воздуха.

Рекомендуемый нами метод лечения, опробованный на нескольких машинах:

  • Для очистки совести проверить разъемы и провода на пути от датчиков концентрации тонера до платы.
  • Проверить систему подачи тонера – часто ломаются шестерни шнеков подачи тонера, которые находятся в блоке ленты переноса.

  • Опустить магнит в бункер отработки, чтобы выяснить имел ли место «вынос» девелопера в отработку.
  • При отсутствии девелопера в бункере отработки вручную добавить и распределить тонер в блок проявки. Добавлять через входное отверстие блока проявки, распределять вращением валов блока проявки за шестерню. Обычно для вывода машины из состояния ошибки достаточно добавить 3-5 г тонера и вращать вручную шестерню блока проявки 2-3 минуты.

  • При присутствии девелопера в бункере отработки сначала вручную добавить совместимый носитель в блок проявки, затем тонер. Добавлять через входное отверстие блока проявки, распределять вращением валов блока проявки за шестерню. Примерное количество носителя, которое нужно добавить, можно выяснить сравнением веса проблемного и «живого» блока проявки.
  • После входа машины на готовность запустить из меню машины процедуру DEV-CLN (1 раз, чтобы не заклинить систему вывода отработки!) затем калибровку цвета. Это позволит машине довести концентрацию тонера до установленных значений.

Профилактика:

  • Обновление прошивки. Kyocera иногда вносит в прошивки коррекции, связанные с алгоритмом подкачки тонера. 
  • Использование «нормального» тонера.
  • Беседа с клиентом о том, что офисная машина предназначена для печати офисных документов, а не для оперативной полиграфии и т.п.

Была ли эта статья полезной?
Да

Нет

Отправить отзыв

К сожалению, мы не смогли помочь вам в разрешении проблемы. Ваш отзыв позволит нам улучшить эту статью.

Статьи по теме

    2JZ/2JX/2JV/2H7-1

    Code

    C7000

    Toner motor problem

    After driving of the toner motor starts, the

    error signal is not at the H level for 500

    ms continuously.

    C7100

    Toner container motor error

    The rated speed achievement signal

    does not turn to L within 2 s since toner

    container motor is activated.

    The rated speed achievement signal is

    at the H level for 1 s continuously after

    toner container motor is stabilized.

    C7101

    Toner sensor K problem

    Sensor output value of 60 or less or 944

    or more continued for 3 s.

    C7102

    Toner sensor C problem

    Sensor output value of 60 or less or 944

    or more continued for 3 s.

    C7103

    Toner sensor M problem

    Sensor output value of 60 or less or 944

    or more continued for 3 s.

    C7104

    Toner sensor Y problem

    Sensor output value of 60 or less or 944

    or more continued for 3 s.

    1-4-46

    Contents

    Causes

    Check procedures/corrective measures

    Poor contact in the

    Check the connection of connector YC26 on

    connector termi-

    the engine PWB and the connector of the

    nals.

    toner motor, and the continuity across the

    connector terminals. Repair or replace if

    necessary.

    Broken the gear.

    Check visually and replace the gear if nec-

    essary.

    Defective toner

    Run maintenance item U135 and check if

    motor M/C/Y/K.

    the toner motor operates. If not, replace the

    toner motor.

    Defective engine

    Replace the engine PWB and check for cor-

    PWB.

    rect operation.

    Poor contact in the

    Check the connection of connector YC26 on

    connector termi-

    the engine PWB and the connector on the

    nals.

    toner container motor, and the continuity

    across the connector terminals. Repair or

    replace if necessary.

    Defective drive

    Check if the rollers and gears rotate

    transmission sys-

    smoothly. If not, grease the bushings and

    tem.

    gears. Check for broken gears and replace if

    any.

    Defective toner

    Run maintenance item U030 and check if

    container motor.

    the toner container motor operates when

    YC26-A7 (remote signal) on the engine

    PWB goes low. If not, replace the toner con-

    tainer motor.

    Defective engine

    Run maintenance item U030 and check if

    PWB.

    YC26-A7 (remote signal) on the engine

    PWB goes low. If not, replace the engine

    PWB.

    Defective develop-

    Replace the developing unit K (see page 1-

    ing unit K.

    5-34).

    Defective PWB.

    Replace the main front PWB or engine PWB

    and check for correct operation.

    Defective develop-

    Replace the developing unit C (see page 1-

    ing unit C.

    5-34).

    Defective PWB.

    Replace the sub front PWB or engine PWB

    and check for correct operation.

    Defective develop-

    Replace the developing unit M (see page 1-

    ing unit M.

    5-34).

    Defective PWB.

    Replace the sub front PWB or engine PWB

    and check for correct operation.

    Defective develop-

    Replace the developing unit Y (see page 1-

    ing unit Y.

    5-34).

    Defective PWB.

    Replace the sub front PWB or engine PWB

    and check for correct operation.

    Remarks

    Описание ошибок:

    · Kyocera ошибка 7401 : XXXXXXX –
    ошибка блока проявки черного цвета.

    · Kyocera ошибка 7402 : XXXXXXX –
    ошибка блока проявки синего цвета.

    · Kyocera ошибка 7403 : XXXXXXX –
    ошибка блока проявки красного цвета.

    · Kyocera ошибка 7404 : XXXXXXX –
    ошибка блока проявки желтого цвета.

    В материале сегодняшнего дня поднимем тему возникновения и решения данной
    ошибки в цветных аппаратах Kyocera
    M5521 / P5021 / / P5026 / M5526 / FS-C5300DN
    / C5350DN / ECOSYS P6030 / FS-C5150DN / ECOSYS P6021 / С8525 / и других.

    В большинстве случаев, причиной возникновения данной ошибки, по мнению
    специалистов нашей компании, является использование некачественного тонера при
    заправке картриджей. В следствии этого нарушается баланс концентрации тонера –
    красящего порошка который переноситься на бумагу и девелопера — ферромагнитного
    порошка с помощью чего тонер переноситься на барабан. В некоторых случаях
    внутренние блоки забиваются так, что валы в них перестаю прокручиваться и
    ломаются.

    Для решения возникшей проблемы можно
    воспользоваться двумя вариантами:

         Первое решение — перезаправка качественным
    тонером или замена его оригинальным и покупка нового блока проявки.
      

    — Этот вариант приводит практически к стопроцентному решению проблемы, но
    требует значительных финансовых затрат. Блок проявки например DV-5230 (цвет
    синий) для аппаратов Kyocera
    M5521 / P5021 на момент написания материала
    стоит 8 500 рублей новый оригинальный тонер картридж от 4 000 тысяч. По самым
    скромным подсчётам получается двенадцать тысяч пятьсот рублей (без учета стоимости
    работ по замене). А если цвет не один – аппарат проще выкинуть ведь новый стоит
    двадцать, тридцать тысяч.

           Второе решение — восстановление
    блока проявки и перезаправка картриджа качественным тонером, что позволит
    значительно сэкономить.

    — для проведения работ аппарат службой доставки перемещается в нашу
    мастерскую.

    — специалисты компании производят необходимые работы.

    — стоимость работ доставкой за один цвет с не превышает трех тысяч рублей.

    — окончательный расчет производится после диагностики в нашем офисе.

    — срок выполнения работ – 24 часа (при наличии на складе расходных
    материалов).

    Особое внимание хотим обратить на использование в данных аппаратах
    картриджей
    Cactus, NVPrint, Colortek. Нам
    неоднократно приходилось ремонтировать аппараты после использования данных
    аналогов.

    Подводя итог всему вышесказанному отметим, что залог долгой работы
    оргтехники это грамотное обращение с ней, а так же использование качественных
    расходных материалов и своевременное обслуживание.

    Нужна консультация? Звоните!
    — 8-(812)-448-58-32

    Thanks Thanks:  0

    Likes Likes:  0

    Dislikes Dislikes:  0

    1. 06-14-2012


      #1

      TaskAlfa 250Ci C7102 — C7103 — C7104 Error Codes

      Dear All Friends

      i have a problem with 250ci (cdc 1725), gaves 7102 — 7103 — 7104
      total counter :90000
      main fw :2H7_2F00_010.007

      all toner and dv units motors are working perfect via simulation.
      What is ur advices?

      Best Redards
      Serdar


    2. 06-14-2012


      #2

      Re: TaskAlfa 250Ci C7102 — C7103 — C7104 Error Codes

      How are the values in U155?

      If they are nearby 20, you lost the 24V for the tonersensors.
      Did someone exchanged the toner container motor in past?
      If yet, please check the wiring above the main front pwb, at a few cases in europe, the wiring would damaged by mounting the plastic cover above the main- and sub front pwb….
      In worst case, the engine pwb is damaged totally, this happened in france.


    3. 06-25-2012


      #3

      Mike L is offline


      Technician


      Rep Power
      22

      Re: TaskAlfa 250Ci C7102 — C7103 — C7104 Error Codes

      you must make an Firmwareupdate the new DV -b working only with the new FW


    4. 06-26-2012


      #4

      Re: TaskAlfa 250Ci C7102 — C7103 — C7104 Error Codes

      Quote Originally Posted by Mike L
      View Post

      you must make an Firmwareupdate the new DV -b working only with the new FW

      Mike L,

      if you are using the old FW you�ll get C7401 !!!
      It�s totally different Errorcode. Unknown Dev-Unit
      But he get Tonersensor Errors.

      Best regards

      KYO_OEM


    5. 12-03-2013


      #5

      Kyocera_77 is offline


      Junior Member


      Rep Power
      0

      Re: TaskAlfa 250Ci C7102 — C7103 — C7104 Error Codes

      any news about this problem?i have the same problem C7103(magenta DV)…firmware update,change DV-M but still the errors there…any suggestion?


    6. 12-04-2013


      #6

      Re: TaskAlfa 250Ci C7102 — C7103 — C7104 Error Codes

      I had a Saturn recently with a dead color developing motor. At first it was giving magenta «Add Toner» indications. With the new motor it changed to C7103, it think.

      The secondary problem was that while the color developing units were not agitating, the toner add system had been packing toner into the magenta developing unit. When it couldn’t take any more it compacted the magenta toner in the spout of the toner cartridge. Once the developing motor was turning again, it took about three days to detone the magenta developer to the point where it tried to add magenta toner, unsuccessfully.

      My solution to the secondary problem was to beat on the toner cartridge until the agitation mechanism would turn again. =^..^=

      If you’d like a serious answer to your request:
      1) demonstrate that you’ve read the manual
      2) demonstrate that you made some attempt to fix it.
      3) if you’re going to ask about jams include the jam code.
      4) if you’re going to ask about an error code include the error code.
      5) You are the person onsite. Only you can make observations.

      blackcat: Master Of The Obvious =^..^=


    7. 05-20-2016


      #7

      brecht2 is offline


      Trusted Tech

      50+ Posts


      Rep Power
      23

      Re: TaskAlfa 250Ci C7102 — C7103 — C7104 Error Codes

      Hello,

      I have a problem with a C7103 on a TA 250ci.
      I got in U155 (Toner senor output) «26» instead of «+300».
      I tried the DV M in another TA300ci and there is de DV M working perfect!
      I changed also the engine pwb without result, changed the DV CMY color motor, front main/sub pcb, motor control pwb without result.
      Could it be a broken gear in the main imaging drive unit?
      This is my last option because it’s a lot of work to disamble this unit!

      Before i had also C2810. I cleaned the waste toner pipe of the ICL motor. It was stuck with toner. (I did the spring back inside)

      thx.


    8. 05-21-2016


      #8

      Re: TaskAlfa 250Ci C7102 — C7103 — C7104 Error Codes

      The Voyager and VoyagerE series both used to shatter the color developer drive gear, but the Saturn series doesn’t seem to do that in my experience. More common is motor failures. Since there are several motors of the same type, I would remove the back to see if the color developer motor is turning. If no, I would swap around the color developing motor to see if a different motor will turn. =^..^=

      If you’d like a serious answer to your request:
      1) demonstrate that you’ve read the manual
      2) demonstrate that you made some attempt to fix it.
      3) if you’re going to ask about jams include the jam code.
      4) if you’re going to ask about an error code include the error code.
      5) You are the person onsite. Only you can make observations.

      blackcat: Master Of The Obvious =^..^=


    9. 05-21-2016


      #9

      brecht2 is offline


      Trusted Tech

      50+ Posts


      Rep Power
      23

      Re: TaskAlfa 250Ci C7102 — C7103 — C7104 Error Codes

      Hello blackcat,

      I’ve changed already the CMY DV motor without result…
      Monday i go back and change the DV M unit with a new one (not a used one).
      I can still print in B&W.


    10. 05-23-2016


      #10

      brecht2 is offline


      Trusted Tech

      50+ Posts


      Rep Power
      23

      Re: TaskAlfa 250Ci C7102 — C7103 — C7104 Error Codes

      Hello,

      Problem solved by swapping the green relay pwb (next to the orange relay pwb) who’s connecting the drums and dv’s.
      DV Magenta toner values again +400.
      Anyway thx to all!


    Bookmarks

    Bookmarks


    Posting Permissions

    • You may not post new threads
    • You may not post replies
    • You may not post attachments
    • You may not edit your posts
    •  
    • BB code is On
    • Smilies are On
    • [IMG] code is On
    • [VIDEO] code is On
    • HTML code is Off

    Forum Rules

    Все современные копировальные аппараты, мфу и принтеры Kyocera имеют возможность диагностировать все узлы устройства в режиме запуска и во время работы аппарата. По этому, если во время включения или во время работы произошел сбой, то техника Kyocera сможет сообщить о наличии ошибки.

    В большинстве случаев у аппаратов Kyocera код ошибки отображается на дисплее, в остальных случаях тип ошибки зависит от последовательности и количества миганий индикаторов.
    Если Ваш копировальный аппарат, МФУ или принтер Kyocera выдал на дисплее некий код, то узнать причину, описание возникновения ошибки, а так же в каком узле аппарата стоит искать проблему, Вы можете в этом разделе выбрав интересующую модель из списка.

    Но диагностика не решит проблему сбоя аппарата, для этого лучше обратиться к профессиональным и опытным сервисным специалистам компании Kyomart! Позвоните нам по телефону
    8 (343) 288-23-45 или отправьте запрос на электронную почту: sales@kyomart.ru , и мы обязательно свяжемся с Вами в кратчайшие сроки.

    Код ошибки Описание ошибки Причина ошибки 0030 FAX control PWB system error
    Processing with the fax software was disabled due to a hardware problem. Defective FAX control PWB. 0060 Engine PWB type error Defective engine sub PCB. 0070 FAX control PWB incompatible detection error
    Abnormal detection of FAX control PWB incompatibility In the initial communication with the FAX control PWB, any normal communication command is not transmitted. Defective FAX software
    Defective FAX control PWB. 0100 Backup memory device error Defective flash memory. 0120 MAC address data error
    For data in which the MAC address is invalid. Defective main PWB.
    Defective flash memory.
    Defective engine PWB. 0130 Backup memory read/write error (main PWB) Defective flash memory.
    Defective main PWB. 0140 Backup memory data error (main PWB) Defective flash memory.
    Defective main PWB. 0150 Backup memory read/write error (engine PWB)
    Detecting engine PWB EEPROM communication error. Improper installation engine PWB EEPROM.
    Defective engine PWB.
    Device damage of EEPROM. 0160 Backup memory data error (engine PWB) Defective flash memory.
    Defective engine PWB. 0170 Billing counting error
    A checksum error is detected in the main and engine backup memories for the billing counters. Data damage of EEPROM.
    Defective PWB. 0180 Machine number mismatch
    Machine number of main and engine does not match. Data damage of EEPROM. 0320 I/O CPU communication error
    A communication error is detected 10 times in succession. Defective PWB. 0630 DMA error DMA transmission of image data does not complete within the specified period of time. Poor contact in the connector terminals. Defective main PWB. 0800 Image processing error
    JAM05 is detected twice. Defective main PWB. 0830 FAX control PWB flash program area checksum error
    A checksum error occurred with the program of the FAX control PWB. Defective FAX software.
    Defective FAX control PWB. 0840 Faults of RTC
    The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed. The battery is disconnected from the main PWB.
    Defective main PWB. 0870 FAX control PWB to main PWB high capacity data transfer error
    High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times. Improper installation FAX control PWB.
    Defective FAX control PWB or main PWB. 0920 Fax file system error
    The backup data is not retained for file system abnormality of flash memory of the FAX control PWB. Defective FAX control PWB. 1010 Lift motor error
    After cassette 1 is inserted, lift sensor does not turn on within 12 s. This error is detected four times successively. Defective bottom plate elevation mechanism in the cassette.
    Defective connector cable or poor contact in the connector.
    Defective drive transmission system of the lift motor.
    Defective lift motor.
    Defective engine PWB. 1020 PF lift motor error (paper feeder)
    After cassette 2 is inserted, PF lift sensor 1 does not turn on within 12 s. This error is detected four times successively. Defective bottom plate elevation mechanism in the cassette.
    Defective connector cable or poor contact in the connector.
    Defective drive transmission system of the PF lift motor 1.
    Defective PF lift motor 1.
    Defective PF main PWB. 1030 PF lift motor error (paper feeder)
    After cassette 3 is inserted, PF lift sensor 2 does not turn on within 12 s. This error is detected four times successively. Defective bottom plate elevation mechanism in the cassette.
    Defective connector cable or poor contact in the connector.
    Defective drive transmission system of the PF lift motor 2.
    Defective PF lift motor 2.
    Defective PF main PWB. 1800 Paper feeder communication error
    A communication error is detected 10 times in succession. Improper installation paper feeder.
    Defective connector cable or poor contact in the connector.
    Defective engine PWB.
    Defective PF main PWB. 1900 Paper feeder EEPROM error
    When writing the data, the write data and the read data is not continuously in agreement 5 times. Defective PF main PWB.
    Device damage of EEPROM. 2000 Main motor steady-state error
    Stable OFF is detected for 1 s continuously after main motor stabilized. Defective connector cable or poor contact in the connector.
    Defective drive transmission system of the main motor.
    Defective main motor.
    Defective engine PWB. 2010 Main motor drive error
    The main motor is not stabilized within 2 s after driving starts. Defective connector cable or poor contact in the connector.
    Defective drive transmission system of the main motor.
    Defective main motor.
    Defective engine PWB. 2101 Developer motor K steady-state error
    The rated speed signal detected the stability OFF continuously for 1 s after the developer motor K stabilizes. Defective connector cable or poor contact in the connector.
    Defective drive transmission system.
    Defective motor.
    Defective PWB. 2102 Developer motor YCM steady-state error
    The rated speed signal detected the stability OFF continuously for 1 s after the developer motor YCM stabilizes. Defective connector cable or poor contact in the connector.
    Defective drive transmission system.
    Defective motor.
    Defective PWB. 2111 Developer motor K startup error
    Developer motor K is not stabilized within 2 s since the motor is activated. Defective connector cable or poor contact in the connector
    Defective drive transmission system.
    Defective motor.
    Defective PWB. 2112 Developer motor YCM startup error
    Developer motor YCM is not stabilized within 2 s since the motor is activated. Defective connector cable or poor contact in the connector
    Defective drive transmission system.
    Defective motor.
    Defective PWB. 2300 Fuser motor steady-state error
    The rated speed signal detected the stability OFF continuously for 1 s after the fuser motor stabilizes. Defective connector cable or poor contact in the connector.
    Defective drive transmission system.
    Defective motor.
    Defective PWB. 2310 Fuser motor startup error
    Fuser motor is not stabilized within 2 s since the motor is activated. Defective connector cable or poor contact in the connector.
    Defective drive transmission system.
    Defective motor.
    Defective PWB. 2550 Conveying motor steady-state error
    The rated speed signal detected the stability OFF continuously for 1 s after the conveying motor stabilizes. Defective connector cable or poor contact in the connector.
    Defective drive transmission system.
    Defective motor.
    Defective PWB. 2560 Conveying motor startup error
    Conveying motor is not stabilized within 2 s since the motor is activated. Defective connector cable or poor contact in the connector.
    Defective drive transmission system.
    Defective motor.
    Defective PWB. 2600 PF drive motor error (paper feeder)
    When the PF drive motor is driven, error signal is detected continuously for 1 s. Defective connector cable or poor contact in the connector.
    Defective drive transmission system of the PF drive motor.
    Defective PF drive motor.
    Defective PF main PWB. 2700 TC belt motor error
    When the TC belt motor is driven, error signal is detected continuously for 1 s. Defective connector cable or poor contact in the connector.
    Defective drive transmission system of the PF drive motor.
    Defective PF drive motor.
    Defective PF main PWB. 3100 ISU home position error
    The home position is not correct when the power is turned on or at the start of copying using the table. Defective connector cable or poor contact in the connector.
    Defective home position sensor.
    Defective ISU motor.
    Defective CCD PWB.
    Defective engine PWB. 3200 Exposure lamp error
    When input value at the time of exposure lamp illumination does not exceed the threshold value between 5 s. Defective connector cable or poor contact in the connector.
    Defective exposure lamp.
    Defective CCD PWB.
    Defective main PWB. 3500 Communication error between scanner and ASIC
    An error code is detected 3 times in succession. Defective connector cable or poor contact in the connector.
    Defective CCD PWB.
    Defective main PWB. 3600 Scanner sequence error Defective main PWB or engine PWB. 4000 Polygon motor synchronization error
    The polygon motor is not stabilized within 10 s after driving starts. Defective connector cable or poor contact in the connector.
    Defective polygon motor.
    Defective engine PWB. 4001 Polygon motor (K) steady-state error
    The rated speed signal detected the stability OFF continuously for 1 s after the polygon motor (K) stabilizes. Defective connector cable or poor contact in the connector.
    Defective motor
    Defective PWB. 4002 Polygon motor (С) steady-state error
    The rated speed signal detected the stability OFF continuously for 1 s after the polygon motor (С) stabilizes. Defective connector cable or poor contact in the connector.
    Defective motor
    Defective PWB. 4003 Polygon motor (M) steady-state error
    The rated speed signal detected the stability OFF continuously for 1 s after the polygon motor (M) stabilizes. Defective connector cable or poor contact in the connector.
    Defective motor
    Defective PWB. 4004 Polygon motor (Y) steady-state error
    The rated speed signal detected the stability OFF continuously for 1 s after the polygon motor (Y) stabilizes. Defective connector cable or poor contact in the connector.
    Defective motor
    Defective PWB. 4010 Polygon motor steady-state error
    Stable OFF is detected for 1 s continuously after polygon motor stabilized. Defective connector cable or poor contact in the connector.
    Defective polygon motor.
    Defective engine PWB. 4011 Polygon motor (K) startup error
    Polygon motor (K) is not stabilized within 10 s since the motor is activated. Defective connector cable or poor contact in the connector.
    Defective motor.
    Defective PWB. 4012 Polygon motor (C) startup error
    Polygon motor (C) is not stabilized within 10 s since the motor is activated. Defective connector cable or poor contact in the connector.
    Defective motor.
    Defective PWB. 4013 Polygon motor (M) startup error
    Polygon motor (M) is not stabilized within 10 s since the motor is activated. Defective connector cable or poor contact in the connector.
    Defective motor.
    Defective PWB. 4014 Polygon motor (Y) startup error
    Polygon motor (Y) is not stabilized within 10 s since the motor is activated. Defective connector cable or poor contact in the connector.
    Defective motor.
    Defective PWB. 4100 BD initialization error
    BD is not detected within 1 s after polygon motor stabilized. Defective connector cable or poor contact in the connector.
    Defective APC PWB.
    Defective BD PWB.
    Defective main PWB. 4600 LSU cleaning motor error
    When the LSU cleaning motor is driven, an error signal is detected continuously for 1 s. Defective connector cable or poor contact in the connector.
    Defective drive transmission system.
    Defective motor. Defective PWB. 4700 VIDEO ASIC device error Defective connector cable or poor contact in the connector.
    Defective main PWB or engine PWB. 4950 LSU CPU communication error
    A communication error is detected 10 times in succession. Defective connector cable or poor contact in the connector.
    Defective PWB. 6000 Broken fuser heater wire
    The detected temperature of fuser thermistor does not reach the specified temperature (ready indication temperature) after the fuser heater has been turned on continuously for 60 s in warming up. The fusing temperature at 7 seconds and 20 seconds since fuser temperature control has occurred differs by 43°C/109.4°F or less. Defective connector cable or poor contact in the connector.
    Deformed connector pin.
    Defective triac.
    Fuser thermostat triggered.
    Broken fuser heater wire.
    Defective engine PWB. 6000
    6020
    6030
    6050 Broken fuser heater wire
    Abnormally high fuser thermistor temperature Broken fuser thermistor wire Abnormally low fuser thermistor temperature Deformed connector pin.
    Defective triac. 6020 Abnormally high fuser thermistor temperature
    The fuser thermistor detects a temperature higher than 230°C/446°F continuously for 40 ms. High fuser temperature signal detects a temperature of 255°C/491°F continuously for 40 ms. Deformed connector pin.
    Defective triac.
    Shorted fuser thermistor.
    Defective engine PWB. 6030 Broken fuser thermistor wire
    A/D value of the fuser thermistor exceeds 251 bit continuously for 7 s during warming up. Defective connector cable or poor contact in the connector.
    Deformed connector pin.
    Defective triac.
    Defective fuser thermistor.
    Defective engine PWB 6050 Abnormally low fuser thermistor temperature
    As the stable temperature has reached the second time, the decrease in the fuser thermistor temperature of 60°C/140°F or greater is detected for one second. Deformed connector pin.
    Defective triac.
    Defective fuser thermistor
    Defective fuser heater.
    Defective engine PWB. 6120 Abnormally high fuser thermistor 3 (press roller) temperature
    The fuser temperature exceeds 200 °C/392 °F for 1 s. Deformed connector pin.
    Defective IH PWB.
    Defective fuser thermistor.
    Defective engine PWB. 6130 Fuser thermistor 3 (press roller) break error Fuser thermistor 3 detects a temperature of -14 °C/6.8 °F . Fuser thermistor 3 does not reach 30° C/86 °F even after20 s during warming up. Defective connector cable or poor contact in the connector
    Deformed connector pin.
    Defective IH PWB.
    Defective fuser thermistor.
    Defective engine PWB. 6150 Abnormally low fuser thermistor 3 (press roller) temperature
    The fuser temperature lower than 30 °C/86 °F is detected continuously for 1 s. Deformed connector pin.
    Defective fuser thermistor
    Defective fuser heater.
    Defective engine PWB. 6200 Broken fuser edge heater wire
    Fuser thermistor 1 does not reach 50° C/122 °F even after20 s during warming up. The detected temperature of fuser thermistor1 does not reach the specified temperature (ready indication temperature) for 20 s in warming up after reaching 50° C/122 °F. Defective connector cable or poor contact in the connector.
    Deformed connector pin.
    Fuser thermostat triggered.
    Broken fuser heater wire.
    Defective engine PWB. 6220 Abnormally high fuser thermistor 1 (edge) temperature
    The fuser temperature exceeds 240 °C/464 °F for 1 s Defective connector cable or poor contact in the connector.
    Deformed connector pin.
    Fuser thermostat triggered.
    Broken fuser heater wire.
    Defective engine PWB. 6230 Fuser thermistor 1 (edge) break error
    During warming up a hearter, fuser thermistor 2 detects a temperature of 100 °C/212 °F or higher and, fuser thermistor 1 detects a temperature of 37 °C/99 °F or lower. Defective connector cable or poor contact in the connector.
    Deformed connector pin.
    Fuser thermostat triggered.
    Broken fuser heater wire.
    Defective engine PWB. 6250 Abnormally low fuser thermistor 1 (edge) temperature
    The fuser temperature lower than 100 °C/212 °F is detected continuously for 1 s during printing. The fuser temperature lower than 50 °C/122 °F is detected continuously for 1 s during pre-heating. Defective connector cable or poor contact in the connector.
    Deformed connector pin.
    Fuser thermostat triggered.
    Broken fuser heater wire.
    Defective engine PWB. 6400 Zero-cross signal error
    While fuser heater control is performed, the zero-cross signal is not input within 3 s. Defective connector cable or poor contact in the connector
    Defective power source PWB or engine PWB. 6410 Fuser unit type mismatch problem
    Absence of the fuser unit is detected. Fuser unit connector inserted incorrectly.
    Different type of the fuser unit is installed. 6600 Belt rotation error
    The belt was detected to stop for 1 s continuously during motor remote is on. Defective fuser motor.
    Defective IH belt.
    Defective IH PWB.
    Defective engine PWB. 7101 Toner sensor K error Defective Developer unit.
    Defective PWB. 7102 Toner sensor C error Defective Developer unit.
    Defective PWB. 7103 Toner sensor M error Defective Developer unit.
    Defective PWB. 7104 Toner sensor Y error Defective Developer unit.
    Defective PWB. 7401 Developing unit K type mismatch problem
    Absence of the developing unit K is detected. Developing unit connector inserted incorrectly.
    Different type of the developing unit is installed.
    Defective PWB. 7402 Developing unit C type mismatch problem
    Absence of the developing unit C is detected. Developing unit connector inserted incorrectly.
    Different type of the developing unit is installed.
    Defective PWB. 7403 Developing unit M type mismatch problem
    Absence of the developing unit M is detected. Developing unit connector inserted incorrectly.
    Different type of the developing unit is installed.
    Defective PWB. 7404 Developing unit Y type mismatch problem
    Absence of the developing unit Y is detected. Developing unit connector inserted incorrectly.
    Different type of the developing unit is installed.
    Defective PWB. 7411 Drum unit K type mismatch problem
    Absence of the drum unit K is detected. Drum unit connector inserted incorrectly.
    Different type of the drum unit is installed.
    Defective PWB. 7412 Drum unit C type mismatch problem
    Absence of the drum unit C is detected. Drum unit connector inserted incorrectly.
    Different type of the drum unit is installed.
    Defective PWB. 7413 Drum unit M type mismatch problem
    Absence of the drum unit M is detected. Drum unit connector inserted incorrectly.
    Different type of the drum unit is installed.
    Defective PWB. 7414 Drum unit Y type mismatch problem
    Absence of the drum unit Y is detected. Drum unit connector inserted incorrectly.
    Different type of the drum unit is installed.
    Defective PWB. 7420 Transfer belt unit type mismatch problem
    Absence of the transfer belt unit is detected. Transfer belt unit connector inserted incorrectly.
    Different type of the transfer belt unit is installed.
    Defective PWB. 7601 ID sensor 1 (front) error Defective ID sensor.
    Defective PWB. 7602 ID sensor 2 (rear) error Defective ID sensor.
    Defective PWB. 7611 ID sensor (K) density error
    When ID sensor 2 detected CTD is 500 or less. Defective ID sensor.
    Defective PWB. 7612 ID sensor (C) density error
    When ID sensor 2 detected CTD is 500 or less. Defective ID sensor.
    Defective PWB. 7613 ID sensor (M) density error
    When ID sensor 2 detected CTD is 500 or less. Defective ID sensor.
    Defective PWB. 7614 ID sensor (Y) density error
    When ID sensor 2 detected CTD is 500 or less. Defective ID sensor.
    Defective PWB. 7620 ID sensor timing error
    Color registration correction was failed. Defective ID sensor.
    Defective PWB. 7800 Broken external thermistor wire
    The thermistor output value is 0.3 V or less. Defective connector cable or poor contact in the connector.
    Defective temperature sensor. 7810 Short-circuited external thermistor wire
    The thermistor output value is 3 V or more. Defective connector cable or poor contact in the connector.
    Defective temperature sensor. 7900 Drum unit EEPROM error
    No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively. Defective connector cable or poor contact in the connector.
    Defective drum unit. 7901 Drum K EEPROM error
    No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively. Defective connector cable or poor contact in the connector.
    Defective drum unit. 7902 Drum C EEPROM error
    No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively. Defective connector cable or poor contact in the connector.
    Defective drum unit. 7903 Drum M EEPROM error
    No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively. Defective connector cable or poor contact in the connector.
    Defective drum unit. 7904 Drum Y EEPROM error
    No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively. Defective connector cable or poor contact in the connector.
    Defective drum unit. 7910 Developer unit EEPROM error
    No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively. Defective connector cable or poor contact in the connector.
    Defective developer unit. 7911 Developing unit K EEPROM error
    No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively. Poor contact in the connector terminals.
    Defective developing PWB. 7912 Developing unit C EEPROM error
    No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively. Poor contact in the connector terminals.
    Defective developing PWB. 7913 Developing unit M EEPROM error
    No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively. Poor contact in the connector terminals.
    Defective developing PWB. 7914 Developing unit Y EEPROM error
    No response is issued from the device in reading/writing for 5 ms or more and this problem is repeated five times successively. Mismatch of reading data from two locations occurs eight times successively. Mismatch between writing data and reading data occurs eight times successively. Poor contact in the connector terminals.
    Defective developing PWB. 8030 Tray upper limit detection problem (document finisher)
    When the tray elevation motor raises a tray, the ON status of the tray upper limit sensor is detected. Defective connector cable or poor contact in the connector.
    Defective tray upper limit sensor, paper surface sensor 1/2.
    Defective DF main PWB. 8040 Belt problem (document finisher)
    The belt sensor does not turn on/off within specified time of the belt solenoid turning on. Defective connector cable or poor contact in the connector.
    Defective belt sensor.
    Defective belt solenoid.
    Defective DF main PWB. 8140 Tray elevation motor problem (document finisher)
    The tray low limit sensor or paper surface sensor 1/2 cannot be detected to be on within 10 s since the tray elevation motor is activated. Defective connector cable or poor contact in the connector.
    Defective connector cable or poor contact in the connector.
    The tray elevation motor malfunctions.
    Defective tray lower limit sensor, paper surface sensor 1/2.
    Defective DF main PWB. 8210 Stapler problem (document finisher)
    Jam 7012 or 7023 is indicated. Defective connector cable of staple or poor contact in the connector.
    The stapler is blocked with a staple.
    The stapler is broken
    Defective DF main PWB. 8320 Adjustment motor 2 problem (document finisher)
    The adjustment sensor 2 does not turn on/off within specified time of the adjustment motor 2 turning on. Defective connector cable or poor contact in the connector.
    Defective adjustment sensor 2.
    Defective adjustment motor 2.
    Defective DF main PWB. 8330 Adjustment motor 1 problem (document finisher)
    The adjustment sensor 1 does not turn on/off within specified time of the adjustment motor 1 turning on. Defective connector cable or poor contact in the connector.
    Defective adjustment sensor 1.
    Defective adjustment motor 1. 8350 Roller motor problem (document finisher)
    The roller sensor does not turn on/off within specified time of the roller motor turning on. Defective DF main PWB.
    Defective connector cable or poor contact in the connector.
    Defective roller sensor.
    Defective roller motor.
    Defective DF main PWB. 8360 Slide motor problem (document finisher)
    The slide sensor does not turn on/off within specified time of the slide motor turning on. Defective connector cable or poor contact in the connector.
    Defective slide sensor.
    Defective slide motor.
    Defective DF main PWB. 8460 EEPROM problem (document finisher)
    Reading from or writing to EEPROM cannot be performed. Defective EEPROM or DF main PWB. 8800 Document finisher communication error
    A communication error is detected 10 times in succession. Defective connector cable or poor contact in the connector
    Defective DF main PWB.
    Defective engine PWB. 8830 Bridge communication error (document finisher)
    A communication error is detected 10 times in succession. Defective connector cable or poor contact in the connector.
    Defective bridge PWB.
    Defective engine PWB. 8990 Document finisher communication error Defective connector cable or poor contact in the connector.
    Defective DF main PWB.
    Defective bridge PWB. 9000 Document processor communication error
    A communication error is detected 10 times in succession. Defective connector cable or poor contact in the connector.
    Defective DP main PWB. 9060 DP EEPROM error Read and write data does not match. Data in the specified area of the backup memory does not match the specified values. Defective DP main PWB.
    Device damage of EEPROM. 9500 BRU communication error IPU PWB error 9510 BRU PWB error IPU PWB error 9520 BRU PWB data error IPU PWB error F000 Main PWB — operation panel PWB communication error Defective main PWB.
    Defective operation panel PWB. F010 Main PWB checksum error Defective main PWB. F040 Main PWB — print engine communication error Defective main PWB.
    Defective engine PWB. F050 Print engine ROM checksum error Defective engine PWB.