Содержание
- Error code 11 1312 xerox b210
- XEROX B205, B210, B215 печатает информационный лист
- XEROX B205, B210, B215 печатает информационный лист
- Коды сброса ошибок копиров, принтеров и МФУ Xerox
Error code 11 1312 xerox b210
«PCL6 ERROR — Incomplete Session by timeout
POSITION: 0x13a3f (0x447)
ERROR CODE : 11-1312″
Story:
I have b215 for 4 weeks, on did face many issues so far.(like : not starting printing any jobs until laptop restart; gibberish symbols printed even from direct webinterface upload pdf (so skipping spooler and system I assume); and also this)
It doesn’t occur everytime, but amount of issues I face for past month is overwhelming.
Connected through wifi, router 0.5m from printer, 0.5m further there’s laptop.
It occured even today — with latest (today checked wupdate, so hopefully after the dread May’s update printer issue) win10 system, latest firmware on printer (88.000.60.000), latest drivers from website.
* (was default) RAW + snmp
* and LPR without snmp and lpr byte counting
Today switched form PCL6 to SPL, will see tomorrow if it occurs again. (I don’t have high hopes about that, but maybe at least error switches from pcl6 error to spl error 🙂
If it does occur I yet plan to check directly using usb cable, but that’s last thing that comes into my mind with this device.
The problem maybe occurs more if I print something, not to anything for like an hour or so, and then try to print again. ?
I’m lost what else can I do.
* Any ideas ?
* Is there some extended debug log to look for issues ? (either windows, or printer?)
* Is this «timeout» somehow controlled in settings? (I only Properties->Security-System timeout, but that doesn’t seems related? I increased it to 10 mins.. didn’t help, should set in hours?)
* is there any certain way to determine is this a driver issue, system (as in windows) issue, or printer issue?
Didn’t yet have the chance to try different device connected to the same driver with wifi, nor different printer to same laptop, that’s on my list.
* any chance it’s related to router or something ?
I really need reliable printer, and can’t go through «restart printer, router & laptop» routine each time I want to print something. maybe I misconfigured something I don’t know..
Источник
XEROX B205, B210, B215 печатает информационный лист
Титульный (информационный) лист — это дополнительная страница с указанием имени пользователя, даты, времени и названия работы. По умолчанию XEROX B205/B210/B215 печатает информационный лист с КАЖДЫМ заданием. Это, на самом деле, является раздражающим фактом, не говоря уже о перерасходе бумаги. Отключить печать титульного листа в устройствах Xerox B205, B210, B215 можно только через веб-интерфейс (приложение Xerox®CentreWare®Internet Services), а простыми словами, через компьютер. Аппарат должен быть подключен к сети Ethernet, Wi-Fi или Wi-Fi Direct.
- Подключить устройство к сети Ethernet:
-
- распечатать отчет о конфигурации (Configuration Report). Он будет нужен для определения IP-адреса и серийного номера устройства. На передней панели аппарата нажать кнопку «Статус аппарата (i)» — далее стрелками выбрать «Информационные страницы» — «ОК»— «Конфигурация» — «ОК» — «Печатать» — «ОК»;
- нажать кнопку вывода меню на передней панели аппарата;
- зайти в настройки сети;
- ввести IP-адрес аппарата (IP-адрес указан в отчете о конфигурации раздел «Network Setup» );
- включить порт Ethernet
( для аппарата B215 ищите подобные кнопки на сенсорном экране )
- Зайти в веб-интерфейс: в компьютере открыть браузер и в адресную строку прописать IP-адрес аппарата.
- Изменить начальный пароль администратора (начальный пароль — это серийный номер аппарата , логин – admin ). Серийный номер аппарата указан в отчете о конфигурации в разделе «Device Profile» — «Machine Serial Number» или в паспортной табличке на задней крышке устройства.
- В веб-интерфейсе выбрать вкладку «Свойства» — «Службы» — «Идёт печать» — «Титульный лист» — «Выключить»—«Применить».
- При запросе авторизации ввести логин — admin и новый пароль.
Также IP-адрес принтера можно узнать на панели управления аппарата:
1. На панели управления принтера нажмите кнопку «На главную»;
2. Нажмите «Аппарат — Об устройстве — Сеть»;
3. Запишите отображаемый IP-адрес;
4. Вернуться в главное меню, нажмите кнопку «На главную».
Иногда, судя по комментариям к этой статье, пользователи не могут войти в веб-интерфейс. Такое может происходить после понижения версии прошивки аппарата. Решением тут может стать сброс настроек принтера до заводских настроек сети по умолчанию. Как это сделать? Приведем выдержку из Руководства пользователя:
ВНИМАНИЕ! При выполнении данной процедуры все сетевые настройки будут удалены, а сетевое соединение с принтером будет немедленно прервано.
1. В приложении Xerox® CentreWare® Internet Services выберите Статус — Общие.
2. Нажмите на Network Factory Default (Заводские настройки сети по умолчанию).
Отобразится предупреждающее сообщение.
3. Для подтверждения нажмите на OK.
Если у вас все же возникли трудности с отключением, вы можете позвонить на горячую линию компании XEROX
Подписывайтесь на нашу группу Вконтакте: https://vk.com/ivmkart
Понравилась статья? Поделитесь с друзьями 🙂
Смотрите в нашем магазине:
Источник
XEROX B205, B210, B215 печатает информационный лист
Титульный (информационный) лист — это дополнительная страница с указанием имени пользователя, даты, времени и названия работы. По умолчанию XEROX B205/B210/B215 печатает информационный лист с КАЖДЫМ заданием. Это, на самом деле, является раздражающим фактом, не говоря уже о перерасходе бумаги. Отключить печать титульного листа в устройствах Xerox B205, B210, B215 можно только через веб-интерфейс (приложение Xerox®CentreWare®Internet Services), а простыми словами, через компьютер. Аппарат должен быть подключен к сети Ethernet, Wi-Fi или Wi-Fi Direct.
- Подключить устройство к сети Ethernet:
-
- распечатать отчет о конфигурации (Configuration Report). Он будет нужен для определения IP-адреса и серийного номера устройства. На передней панели аппарата нажать кнопку «Статус аппарата (i)» — далее стрелками выбрать «Информационные страницы» — «ОК»— «Конфигурация» — «ОК» — «Печатать» — «ОК»;
- нажать кнопку вывода меню на передней панели аппарата;
- зайти в настройки сети;
- ввести IP-адрес аппарата (IP-адрес указан в отчете о конфигурации раздел «Network Setup» );
- включить порт Ethernet
( для аппарата B215 ищите подобные кнопки на сенсорном экране )
- Зайти в веб-интерфейс: в компьютере открыть браузер и в адресную строку прописать IP-адрес аппарата.
- Изменить начальный пароль администратора (начальный пароль — это серийный номер аппарата , логин – admin ). Серийный номер аппарата указан в отчете о конфигурации в разделе «Device Profile» — «Machine Serial Number» или в паспортной табличке на задней крышке устройства.
- В веб-интерфейсе выбрать вкладку «Свойства» — «Службы» — «Идёт печать» — «Титульный лист» — «Выключить»—«Применить».
- При запросе авторизации ввести логин — admin и новый пароль.
Также IP-адрес принтера можно узнать на панели управления аппарата:
1. На панели управления принтера нажмите кнопку «На главную»;
2. Нажмите «Аппарат — Об устройстве — Сеть»;
3. Запишите отображаемый IP-адрес;
4. Вернуться в главное меню, нажмите кнопку «На главную».
Иногда, судя по комментариям к этой статье, пользователи не могут войти в веб-интерфейс. Такое может происходить после понижения версии прошивки аппарата. Решением тут может стать сброс настроек принтера до заводских настроек сети по умолчанию. Как это сделать? Приведем выдержку из Руководства пользователя:
ВНИМАНИЕ! При выполнении данной процедуры все сетевые настройки будут удалены, а сетевое соединение с принтером будет немедленно прервано.
1. В приложении Xerox® CentreWare® Internet Services выберите Статус — Общие.
2. Нажмите на Network Factory Default (Заводские настройки сети по умолчанию).
Отобразится предупреждающее сообщение.
3. Для подтверждения нажмите на OK.
Если у вас все же возникли трудности с отключением, вы можете позвонить на горячую линию компании XEROX
Подписывайтесь на нашу группу Вконтакте: https://vk.com/ivmkart
Понравилась статья? Поделитесь с друзьями 🙂
Смотрите в нашем магазине:
Источник
Коды сброса ошибок копиров, принтеров и МФУ Xerox
В данной таблице предоставлены коды сброса ошибок популярных моделей аппаратов разных производителей. В левой колонке указана модель аппарата, в правой — метод сброса. Для большинства моделей данной фирмы вход в сервисный режим одинаков — удерживая «0» включить агрегат.
Другие способы входа в сервисный режим
Xerox 5845, 5855 | Либо включить аппарат с одновременно нажатыми кнопками [Прерывание] и [2] либо на включенном аппарате нажать и удерживать эти кнопки более 2 сек. Если аппарат неисправен — вход осуществляется кнопками [Прерывание] и [5], с ограничением функций (последовательно появляющиеся сообщения о неисправностях сбрасываются двойным нажатием клавиши [Стоп]). Далее аппарат запрашивает четырёхзначный код доступа: это либо 8765 (по умолчанию), либо последние четыре цифры счётчика копий в обратном порядке (если счётчик копий показывает 01234567 — код входа 7654). |
Xerox N17 24/32/40 3225/4025 |
Есть 3 диагностических режима: 1 — проверяются выключатели, датчики и выводятся параметры фьюзера; вход: (2+6), после «IOT?» нажать «7»; 2 — печатается тест-лист «сетка» в симплексе или дуплексе; вход: (2+6), после «IOT?» нажать «4»; 3 — меняются параметры и настройки принтера (NVRAM); вход: (2+6), после «IOT?» нажать (4+7), «7» сразу же отпустить; «4» держать до появления «3» на дисплее, затем отпустить. |
XD102. 155 XE60. 84 XC800. 1255 |
stop – auto – stop – auto иногда записывают как C – Density select – C – Density select (что то же самое) |
WC PE 16(e) | набираем на клавиатуре [menu] — [#] — [1934] — [menu]; после входа в сервисное меню появится надпись «TECH» |
Для выхода из режима дважды нажимаем кнопку «Сброс» или выключаем и снова включаем аппарат.
Возможные проблемы
Xerox 5201/5203/5305/5306 XC351/355/356 | Обнуление счетчика фоторецептора. Признак — моргают все лампы, в готовность не выходит.
|
Xerox ХC520/540/560/580 | Сброс ошибки Н3/Н4.
|
Xerox N17, N2125 24/32/40 3225/4025 N2025/2825 Phaser 5400 |
Эти модели имеют счетчик фьюзера. По его окончании аппарат просит заменить набор регламентных работ или «Maintenance Kit». Этот счетчик тоже можно сбросить, если печка в порядке: (2+6), вкл. питание, дождаться «IOT?», не позднее 5 сек. после появления «IOT?» нажать (0+5) и держать до появления сообщения о сбросе «Reset Complete. Please Reboot». Выключите и включите принтер. Рекомендация: все же лучше не просто сбрасывать счетчик, а устанавливать набор, в который входят фьюзер в сборе, ролик переноса, ролики подачи (6 или 15), протирочная салфетка |
WC РE16(e)
Samsung SCX 4016/4116/4216(F) |
Сброс сообщения «Нет тонера» после заправки — есть два варианта: 1. Поставить в паз на передней части картриджа предохранитель на 1/16А (0.0625А), при первом же включении аппарат пережгёт предохранитель и сообщение сбросится. Известны случаи, что работало и с предохранителем до 0.5А; но если МФУ предохранитель не сможет сжечь, будет ошибка CRU FUSE ERROR, которая уходит после установки более слабого предохранителя. 2. Через сервисное меню: для входа в сервисное меню 4216/PE16 набираем на клавиатуре : [menu] — [#] — 1934 — [menu], (для 4016/4116 — [menu] — [upper level] — [Стрелка влево] — [Стрелка вправо] — [upper level] — [enter]). После входа в сервисное меню появится надпись TECH; с помощью клавиш [Стрелка влево] — [Стрелка вправо] находим запись «New cartridge», выбираем «Yes». Для выхода из сервисного меню просто выключаем и включаем МФУ (или для 4216/PE16 набираем на клавиатуре [menu] — [#] — 1934). |
Xerox 4030 | Процедура одинакова для обоих картриджей: удерживая кнопку сброса, находящуюся рядом со шнуром питания; включите принтер. |
Xerox 5017/5316/5317 | Сброс барабана (ошибка J7): на платке с EPROM запаиваем F2, а вместо F1 включаем тестер в режиме измерения тока на пределе 3 mA с защитой. Делаем 101 копию, и – привет! |
DC 212/214 | Сброс ошибки U4. Войдите в диагностический режим и подождите 30 сек, пока аппарат завершит инициализацию. Введите диагностический код [401] и нажмите кнопку «Старт». Выйдите из диагностики, выключите аппарат. Подождите 10 сек, включите аппарат. Подождите 30 сек. Если код U4 появился снова, повторите процедуру сброса. Если после 3-х процедур код появляется вновь, но Вы уверены в работоспособности фьюзера — замените главную плату. |
WC Pro 320 | Сброс кода U4 (печная ошибка) – код 10-1, введите 0 и нажмите кнопку [Старт] |
WC Pro 610 | Тонер: включите аппарат, откройте крышку; нажмите [MENU], [6], [3], [CLEAR], [ENTER] Барабан: включите аппарат, откройте крышку; нажмите [MENU], [6], [4], [CLEAR], [ENTER] |
XD155df | после сброса счётчика 24-7 в 26-38 пропиши 1 – больше считать не будет. |
XE 60/80 | Сброс OPC Cartridge: при включенном питании откройте переднюю крышку; удерживая кнопку [Copy Contrast], закройте крышку и продолжайте держать кнопку 3 секунды. |
Xerox 5845 | При включении требует ввести пользовательский код или кликнуть администратора. Надо войти в «АДМИНИСТРАТОР» (код 11111), затем ввести новый счет; или заблокировать аудитрон. |
НИКОГДА не используйте никаких других диагностических кодов и процедур, потому что это может привести к непредсказуемым последствиям.
Имейте в виду, что сброс ошибки не гарантирует вас от всех остальных бед, поэтому при первой же возможности завезите копировальный аппарат в сервисную фирму, чтобы там удалили отработку, произвели необходимую чистку и регулировки.
Источник
Современные копировальные аппараты Xerox отличаются качество, надежностью и «быстрым» стартом. Также у них существует множество особенностей, которые отличают их от принтеров других производителей. Например, используется тефлоновый вал, а не термопленка.
Однако избегать различных поломок и ошибок пока не удается ни одному устройству. К самым частым неисправностям у принтеров Xerox относятся: залипание или повреждение датчика бумаги, повреждение роликов подачи, часто требуется перепрошивка программного обеспечения.
Если у вас возникнут вопросы насчет того, как исправить код ошибки копировального аппарата Xerox, то вы можете обратиться к специалистам нашего сервисного центра.
Основные коды ошибок копировальных аппаратов Xerox и способы их устранения:
- Коды ошибок Xerox 1012, 1012(RE)
- Коды ошибок Xerox 1020
- Коды ошибок Xerox 1025
- Коды ошибок Xerox 1035
- Коды ошибок Xerox 1038
- Коды ошибок Xerox 2830
- Коды ошибок Xerox 5011, 5012, 5014
- Коды ошибок Xerox 5016, 5017, 5316, 5317
- Коды ошибок Xerox 5018, 5028
- Коды ошибок Xerox 5312, 5313, 5314
- Коды ошибок Xerox 5318, 5320, 5322
- Коды ошибок Xerox 5328
- Коды ошибок Xerox 5330
- Коды ошибок Xerox 5340, 5343
- Коды ошибок Xerox 5345
- Коды ошибок Xerox 5350, 5352
- Коды ошибок Xerox 5355
- Коды ошибок Xerox 5622
- Коды ошибок Xerox XC520, 540, 560, 580
Xerox 1012, 1012(RE)
Код ошибки | Описание |
---|---|
E1 | Jam between paper feed and fuser |
E3 | Jam in fuser |
E5 | Clam shell open |
E6 | Paper feed section cover is open |
J1 | Toner cartridge near empty |
J3 | Drum cartridge not seated properly |
J7 | Waste toner full (replace drum cartridge) |
L6 | Key counter out |
L8 | Exposure area overheat |
U1 | No clock pulse (drive problem) |
U2 | Scan problem |
U3 | Lens/mirror problem (RE model only) |
U4 | Heat problem |
U8 | Exposure lamp control circuit problem |
E1 | Jam between paper feed and fuser |
E3 | Jam in fuser |
E5 | Clam shell open |
E6 | Paper feed section cover is open |
J1 | Toner cartridge near empty |
J3 | Drum cartridge not seated properly |
J7 | Waste toner full (replace drum cartridge) |
L6 | Key counter out |
L8 | Exposure area overheat |
U1 | No clock pulse (drive problem) |
U2 | Scan problem |
U3 | Lens/mirror problem (RE model only) |
U4 | Heat problem |
U8 | Exposure lamp control circuit problem |
Xerox 1020
Код ошибки | Описание |
---|---|
LL | Probable bad heater lamp |
Xerox 1025
Код ошибки | Описание |
---|---|
A1 | DF jam |
C1 | PF jam cass. 1 |
C2 | PF jam cass. 2 |
C3 | PF jam cass. 3 |
C9 | Bypass jam |
E1-1 | Paper jam before exit switch |
E1-2 | Paper jam |
E1-5 | Paper jam |
E1-6 | Paper jam |
E3-3 | Paper jam at exit switch |
E3-4 | Paper jam at exit switch |
E5 | Front door open |
F1 | Collator jam |
F5 | Collator interlock |
F8 | No power to collator |
F9 | Collator bin home switch |
J7 | 250 copies since toner waste was full |
L5 | Original cass. not present after clearing interrupt |
L6 | Key counter |
L8 | Platen glass too hot |
U1 | Main motor clock pulse |
U2 | Scan problem |
U3-1 | Lens problem |
U4-1 | Open thermistor |
U4-2 | Low temperature |
U4-4 | Temperature |
U4-5 | Main PWB |
U6-1 | Main PWB |
U6-2 | Main PWB |
U6-3 | Main board battery |
U6-4 | Initialization |
U8 | Exposure lamp |
Xerox 1035
Код ошибки | Описание |
---|---|
A9 | Scanner location |
C1 | Paper feed — upper cassette |
C2 | Paper feed — lower cassette |
C9 | Bypass jam |
E5 | Clam shell is open |
L6 | Key counter |
U1 | Off/On |
U2 | Optics |
U4 | Low fuser temperature |
Xerox 1038
Код ошибки | Описание |
---|---|
A1 | DF jam |
C1 | PF jam cass. 1 |
C2 | PF jam cass. 2 |
C3 | PF jam cass. 3 |
C9 | Bypass jam |
E1-1 | Paper jam before exit switch |
E1-2 | Paper jam |
E1-5 | Paper jam |
E1-6 | Paper jam |
E3-3 | Paper jam at exit switch |
E3-4 | Paper jam at exit switch |
E5 | Front door open |
F1 | Collator jam |
F5 | Collator interlock |
F8 | No power to collator |
F9 | Collator bin home switch |
J7 | 250 copies since toner waste was full |
L5 | Original cass. not present after clearing interrupt |
L6 | Key counter |
L8 | Platen glass too hot |
U1 | Main motor clock pulse |
U2 | Scan problem |
U3-1 | Lens problem |
U4-1 | Open thermistor |
U4-2 | Low temperature |
U4-4 | Temperature |
U4-5 | Main PWB |
U6-1 | Main PWB |
U6-2 | Main PWB |
U6-3 | Main board battery |
U6-4 | Initialization |
U8 | Exposure lamp |
Xerox 2830
Код ошибки | Описание |
---|---|
A9 | Scanner location |
C1 | Paper feed — upper cassette |
C2 | Paper feed — lower cassette |
C9 | Bypass jam |
E5 | Clam shell is open |
E5 | Clam shell open |
L6 | Key counter |
U1 | Off/On |
U2 | Optics |
U4 | Low fuser temperature |
Xerox 5011, 5012, 5014
Код ошибки | Описание |
---|---|
C8 | Bypass jam/no paper |
C9 | Bypass jam |
E1 | Jam |
E3 | Fuser jam |
E5 | Clamshell open |
E6 | PF section cover open |
J1 | Toner cartridge amost empty |
J3 | Copy cart (drum unit) missing/not seated right |
J7 | Copy cartridge has run 18,000 copies |
J8 | Copy cartridge. Improperly seated or possible only one of two fuses in the cartridge blew |
L6 | Key counter |
L8 | Exposure glass too hot |
U1 | Drive problem |
U2 | Scan problem |
U3 | Lens or mirror drive problem |
U4 | Fuser problem. Heat lamp, thermoswitch, SSR, thermistor |
U6 | Battery on main board |
U8 | Exposure lamp or exposure lamp circuit |
Xerox 5016, 5017, 5316, 5317
Code | Description |
---|---|
A1-1 | Document feeder feed jam |
A1-2 | Document feeder belt jam |
A2-1 | Document feeder exit jam |
A2-2 | Duplex jam |
A3 | DAD interlock |
A5 | Duplex and DAD right side interlock |
A6 | Copier jams after |
A9 | Document feed belt drive motor |
C1-3 | Top cassette misfeed |
C2-3 | Middle cassette misfeed |
C3-3 | Bottom cassette misfeed |
C9-3 | Bypass misfeed |
E1-11 to E1-14 | Paper jam in machine. Did not reach exit switch soon enough |
E1-6 | Paper path jam |
E3-31 to E3-34 | Exit switch jam |
E3-6 | Fuser jam |
E5 | Front door interlock |
E6 | Right side interlock or TTM interlock |
F1 | Sorter jam |
F5 | Sorter interlock |
F8 | Sorter board to copier main board communication problem |
F9 | Sorter bins |
Xerox 5018, 5028
Code | Description |
---|---|
A1 | Document is ADF |
A1-8 | Main board received reset signal |
A2 | ADF jams |
A6, A7 | ADF jams |
A9 | ADF jams |
C1 — C4 | Feed jam |
C5-1 to C5-4 | Jams in various areas |
C5-2 | Jams in various areas |
C5-3 | Jams in various areas |
C5-4 | Duplex jam |
E0 | Machine has reset |
E1 | Jam |
E1-E0 | Registration jam |
E1-E5 | Clamshell interlock |
E1-E6 | Right side interlock |
E1-E7 | Two tray interlock |
E1-E8 | Sorter interlock |
E1-E9 | Copy cartridge interlock |
E2 | Reset signal happened |
E3 | Jam |
E4 | Exit jam |
E4-10 | Exit jam |
E4-5 | Clamshell interlock |
E4-6 | Right side interlock |
E4-7 | Two tray interlock. Duplex interlock |
E4-8 | Sorter interlock |
E4-9 | Copy cartridge interlock |
E5 | Clamshell interlock |
E6 | Right side interlock |
E7 | Duplex interlock |
E9 | Copy cartridge interlock |
F3-1 | Sorter bin home switch |
F3-2 | Sorter cam switch |
F3-3 | Sorter cam switch |
J1-1 | Add toner |
J1-2 | Temporary low toner signal |
J2-0 | Replace copy cartridge |
L2 | 2000 copies left on copy cartridge |
L3 | ADF to machine communication problem |
L4 (flashing) | 1000 copies left on fuser web |
rr | Bad EPROM on main board |
U0 | Main board |
U2 | Scan problem |
U2-1 | Scan home |
U3-00 | Cam drive problem |
U3-01 | Cam movement slow |
U3-04 | Main board to duplex communication |
U3-09 | Cam problem |
U3-12 | Jogger problem |
U3-19 | Cam problem |
U3-21 | Cam problem |
U3-23 | Cam problem |
U3-29 | Cam problem |
U3-32 | Cam problem |
U3-34 | Cam problem |
U3-39 | Cam problem |
U3-43 | Cam problem |
U3-45 | Cam problem |
U3-49 | Cam problem |
U3-54 | Cam problem |
U3-56 | Cam problem |
U3-59 | Cam problem |
U4-1 | Fuser problem. Long warm up |
U4-2 | Low fuser temperature after warm up |
U4-3 | High fuser temperature |
U4-4 | Open fuser thermistor |
U4-6 | Replace fuser web |
U4-7 | Thermistor signal problem |
U7-1 | Copy cartridge belt drive problem |
U9-3 | Exposure lamp problem |
U9-4 | Toner motor |
U9-5 | Problem in warm up |
Xerox 5312, 5313, 5314
Код ошибки | Описание |
---|---|
C1 | Upper paper feed problem. Did not reach feed sensor |
C2 | Lower paper feed problem. Did not reach feed sensor |
E1 | Exit jam. Paper did not reach exit sensor |
E3 | Exit jam. Paper still on exit sensor |
J1 | Add toner |
J3 | Copy cartridge (drum unit) not installed |
J7 | Copy cartridge (drum unit) must be replaced |
J8 | Copy cartridge (drum unit) problem |
L6 | Problem with an accessory. Installed but not initialized |
U1 | Drive problem. Main motor, gear etc. |
U2 | Scan problem |
U3 | Main board dip switches wrong. Lens drive problem |
U4 | Fuser problem. Heat lamp, thermal switch, overheat, thermistor. |
U6 | EPROM error |
U8 | Auto exposure sensor. No exposure lamp or weak lamp |
Xerox 5318, 5320, 5322
Code | Description |
---|---|
A1-11 | Original ready switch |
A1-12 | Feed sensor |
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF |
A1-21 | Original ready switch and document registration sensor or both the document feed sensor and document registration sensor |
A1-22 | ADF registration sensor |
A1-23 | Original did not reach ADF registration sensor quickly enough |
A1-24 | ADF sensor stuck down too long |
A1-25 | ADF sensor actuated at the wrong time during single sheet feed |
A1-26 | ADF sensor not actuated quickly enough in sheet feed mode |
A1-31 | In reverse, ADF sensor is not actuated soon enough |
A1-32 | In reverse, ADF sensor is actuated too long |
A2 | ADF exit problems |
A2-1 | Original ready sensor and ADF exit switch are actuated or ADF feed in sensor and ADF exit switch are both actuated |
A2-2 | ADF exit switch |
A2-3 | ADF exit switch is not actuated on time |
A3 | Irregular size documents |
A3-1 | Wrong size original sensed in 1:1 mode |
A3-2 | Wrong size original sensed in the 2:1 mode |
A5 | ADF interlock |
A5 | ADF interlock |
A6 | ADF single sheet document reset. |
A6-1 | Reset original |
A6-2 | Reset sheet feeder |
A7 | Document cover interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C1-2 | Paper feed problem in tray 1 |
C1-3 | Paper does not reach registration |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C3-1 | Paper feed problem from tray 3 |
C3-2 | Paper feed problem from tray 3 |
C3-3 | Paper feed problem from tray 1 |
C6-1 | Duplex paper feed problem |
C6-2 | Duplex and/or tray 1 paper feed problem |
C6-3 | Paper feed problem from tray 1 |
C7-1 | Paper feed problem from HCF |
C7-2 | Paper feed problem from HCF on tray 1 |
C7-3 | Paper feed problem from tray 1 |
C8 | Paper stays in tray or duplex or HCF |
C8-1 | Paper on tray 1 feed sensor |
C8-2 | Paper on tray 2 feed sensor |
C8-3 | Paper on tray 3 feed sensor |
C8-4 | Paper on HCF feed sensor |
C8-5 | Paper in duplex section |
C9 | Bypass feed problem |
C9-3 | Paper from bypass did not reach registration sensor quickly enough |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else. |
E3-30 to E4-14 | Exit jam |
E3-30 to E3-35 | Exit switch actuated too long |
E3-6 | Exit jam |
E3-6 | Paper on exit switch |
E4-10 to E4-14 | Inverter sensor not actuated. |
E4-10 to E4-45 | Paper did not reach inverter switch soon enough |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Paper on inverter switch |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2 | Duplex inverter interlock |
E7-3 | Duplex interlock |
E8-10 to E8-15 | Paper on duplex feed sensor is not actuated soon enough |
E8-6 | Paper in duplex |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Paper did not reach sorter |
F1-2 | Paper stayed on sorter feed sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
H2-1 | Communication problem between main board and duplex board |
H2-2 | Side guard sensor problem |
H3-1 | Communication problem between main board and HCF |
H3-2 | Upper limit sensor problem on HCF |
H6-1 | ADF size sensor |
H6-2 | ADF nudgeer sensor |
H6-3 | Belt drive motor does not have 24 volts. Black toner is empty, but 100 copies have been run without changing toner |
J1 | Black toner is empty, but 100 copies have been run without changing toner |
J3 | Replace copy cartridge |
J3 | No copy cartridge (drum unit) |
J7 | Copy cartrige must be replaced |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM must be changed |
L6 | Auditron or other counter problem |
L6 | Key counter not installed |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 | Scan home problem |
U2-1 to U2-4 | Scan home sensor |
U2-2 | Scan home problem or optics problem |
U2-3, U2-4 | Scan home problem |
U3-1 | Lens sensor problem |
U4-1 | Fuser thermistor open |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3 | Sorter bin home switch |
U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 | Exposure lamp problem |
U8-2 | Communication problem main board and exposure board |
U8-3 | Exposure lamp or exposure lamp board problem |
U8-4 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Xerox 5328
Code | Description |
---|---|
A1 | Document in ADF |
A1-8 | Main board received reset signal |
A2 | ADF jams |
A6 | ADF registration jam |
A7 | ADF interlock |
A9 | Tray 1 jam |
C1 | Tray 2 jam |
C2 | Tray 3 jam |
C3 | Bypass feed jams |
C4 | Machine has reset |
E1 | Jam |
E1-5 | Clamshell interlock |
E1-6 | Right side interlock |
E1-7 | Two tray interlock, or duplex interlock |
E1-8 | Sorter interlock |
E1-9 | Copy cartridge interlock |
E1 or E1-0 | Registration jam |
E2 | Reset signal happened |
E3 | Jam in transfer area |
E4 | Exit jam |
E4-0 | Exit jam |
E4-5 | Clamshell interlock |
E4-6 | Right side interlock |
E4-7 | Two tray interlock |
E4-8 | Sorter interlock |
E4-9 | Copy cartridge interlock |
E5 | Clamshell interlock |
E6 | Right side interlock |
E9 | Copy cartridge interlock |
F3-1 | Sorter bin home switch |
F3-2 | Sorter cam switch |
F3-3 | Sorter cam switch |
F5 | Sorter interlock |
J1-1 | Add toner |
J1-2 | Temporary low toner signal |
J2-1, J2-2 | Replace copy cartridge |
J5, J6 | ADF to machine communications problem |
L2 | 2000 copies left on cartridge |
L3 | ADF to machine communications problem |
L4 | (flashing) 1000 copier left on fuser web |
L6 | Auditron or other counter problem |
LL | Main board. Try simulation 1.1 to initialize |
rc | Wrong operation panel installed |
rr | Bad EPROM on main board. Try 1.1 |
U0 | Main board |
U2 | Scan problem |
U2-1 | Scan home |
U2-2 | Scan home or scan encoder |
U2-4 | Scan home or scan dual page sensor |
U2-7 | Scan home |
U4-1 | Fuser problem. Long warm up |
U4-2 | Low fuser temperature after warm up |
U4-3 | High fuser temperature |
U4-4 | Open fuser thermistor |
U4-6 | Replace fuser web. |
U4-7 | Thermistor signal problem |
U7-1 | Copy cartridge belt drive problem |
U9-3 | Exposure lamp problem |
U9-4 | Toner motor |
U9-5 | Problem in warm-up |
Xerox 5330
Code | Description |
---|---|
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF. |
A2 | ADF exit problems |
A3 | Irregular size documents |
A5 | ADF interlock |
A6 | ADF single sheet document reset. |
A7 | Platen interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C6-1, C6-2 | Jams related to duplex |
C6-3 | Registration sensor, re tray 1 |
C7-1, C7-2 | HCF feed problems |
C7-3 | Tray 1 feed problem |
C8 | Paper stays in tray or duplex or HCF |
C9 | Bypass feed problem |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else. |
E3-30 to E4-14 | Exit jam |
E3-6 | Exit jam |
E4-10 to E4-14 | Inverter sensor not actuated. |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2, E7-3 | Duplex interlock |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Sorter entry sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
J1 | Add toner |
J3 | Replace copy cartridge |
J7 | Replace copy cartridge |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM |
L6 | Auditron or other counter problem |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 to U2-4 | Scan home sensor |
U3-1 | Lens sensor |
U4-1 | Open fuser thermistor |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3 | Sorter bin home switch |
U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Xerox 5340, 5343
Code | Description |
---|---|
00-009; 030 to 033 | A door was opened while paper was being fed |
00-047 | Paper in duplex |
00-1 | Auditron |
00-2 | Diagnostic error |
00-3 | Faults error |
00-4 | Ric error |
00-5 | Job manager system error |
00-6 | LLM interface |
00-7 | Standby error |
00-8 | Communications error |
00-9 | Xerographic error |
01-300 | Front interlock |
01-310 | Right upper interlock |
01-315 | Left upper interlock |
01-320 | Left lower interlock |
01-325 | Fuser interlock |
02-910 | Key counter missing |
02-920 | Wrong combination of accessories |
03-321, 322, 326, 327 | LLM to ISIL communications problems |
03-328 | IOT communications problem with duplex or tray 4 |
03-330 | IOT communications problems with HCF |
03-335, 03-336 | LLM communications problems with edit |
03-340 | NVM memory |
03-341, 03-347 | Communications problems between IOT and sorter |
03-350, 03-354 | Communications problem with LLM and user interface |
03-363, 03-364 | Communications problem between LLM & optics |
03-370, 03-373 | Communications problem between LLM & DADF |
03-380, 384 | |
03-416, 03-422 | RAM memory problem |
03-424, 426 | NVM memory problem |
03-430, 432 | Billing problem |
03-439 | GRAIB communications problem |
03-440 | RIC communications problem |
03-441 | RIC NVM problem |
03-442 | Modem |
03-443, 03-458 | RIC problems |
03-460 | Serial communications processor problem |
04-300 | Main motor or drive problem |
05-100, 05-108 | DADF registration sensor |
05-110 | DADF exit sensor |
05-115, 120 | DADF jams |
05-305 | DADF document drive |
05-310, 312 | DADF document sensor |
05-316 | DADF registration sensor jam |
05-325 | DADF exit sensor |
05-335, 341, 345 | DADF interlock switches |
06-300, 06-310 | Scan problems |
06-315 | Scan drive |
06-320A, 320B, 320C, 325 | Scan problem |
06-330 | Lens drive |
06-340 | Exposure control problem |
06-342 | LLM CPU problem |
06-344, 06-350 | Exposure cvontrol problem |
06-352 | IOT CPU problem |
07-300, 315, 330, 345 | Tray faults |
07-360, 07-370 | HCF problems |
07-375, 380A, 380B | Duplex problems |
08-100, 08-110 | Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1 |
08-115, 08-162 | Feed problem. Lead edge of copy paper is late getting to registration sensor |
08-165 | Paper jam at registration sensor |
08-310, 08-370 | Paper at a sensor when power is turned on |
08-330 | DADF nudger sensor |
08-380 | Registration side to side problem with home position |
08-390 | Nip |
09-300 | Copy cartridge finished (drum unit) |
09-310 | Add black toner Add color toner |
09-320 | Add color toner |
09-330 | Wrong copy cartridge (wrong drum unit) |
09-340 | Drum cartridge not installed properly |
09-350 | Waste toner full |
100 | A fault has occurred |
10-100 | Exit jam |
10-105 | Exit jam |
10-110 | Vertical sensor jam |
10-120, 122, 125 | Duplex jam |
10-150, 155 | Too much or not enough paper in duplex tray |
10-300 | Fuser thermistor |
10-302 | Low fuser temperature |
10-304 | Bad fuser temp |
10-308 | High fuser temperature or open thermistor |
10-310 | High fuser temperature |
10-312 | Fuser not up to temperature after energy save |
10-314 | Fuser problem |
10-320 | Fuser web finished |
10-330, 335, 340 | Exit switch, vertical sensor switch actuated when power is turned on |
11-100, 11-116 | Sorter jam |
11-150, 11-176 | Sorter auto stapler jam |
11-310, 314, 316 | Sorter interlock |
11-325A, B, C, D, E, F, G | Sorter index |
11-352, 354, 356 | Sorter auto stapler interlocks |
11-365A, B, C, D, E | Sorter auto stapler bin |
11-370, 371, 372A, 373A, 373B, 374 | Sorter auto stapler staple failure, staple home problem or tamper home problem |
11-385A, 385B, 390A,B,C,D,E, 396A | Sorter auto stapler staple failure, staple home problem or tamper home problem |
301 | Fuser web must be replaced |
302 | Copy cartridge (drum unit) must be replaced |
501 | Tray 1 must be rebuilt |
502 | Tray 2 must be rebuilt |
503 | Tray 3 must be rebuilt |
504 | Tray 4 must be rebuilt |
505 | HCF must be rebuilt |
506 | Bypass must be rebuilt |
507 | Duplex unit must be rebuilt |
508 | Replace black developer |
509 | Replace red developer |
510 | Replace green developer |
512 | Replace brown developer |
513 | Copy cartridge (drum unit) will need replacing soon |
514 | Fuser web will need replacing soon |
515 | DADF belt should be replaced |
516 | DADF feed rollers should be replaced |
517 | Replace exposure lamp |
518 | Replace suction filter |
519 | Replace ozone filter |
520 | Replace optics filter |
521 | Replace particle filter |
522 | Replace upper fuser roller |
523 | Replace fuser pawls |
524 | Replace pressure roller |
525 | Replace pressure roller pawls |
900-905 | Key operator calls |
Xerox 5345
Код ошибки | Описание |
---|---|
01-01 | Frequency monitoring and zero cross problem |
01-02 | Interlock |
01-03 | AC power problem |
01-04 | Finisher interlock |
01-05 | 24v problem |
03-01 | Optics to main board communication problem |
03-02 | Software reset problem |
03-03 | Could be punched holes in the lead edge of the original |
03-04 | Software problem |
03-06 | Low battery |
03-07 | NVM not initialized or is missing or defective |
03-17 | Communication problem between main board and finisher board |
03-18 | Initializes one NVM counter to agree to others |
03-19 | All three NVM counter to agree with others |
03-20 | Main board/interface board problems |
03-21 | Problem with RIC NVM |
03-22 | RIC modem problem |
03-23 | RIC real time clock failure. |
03-25 | RIC NVM problem or not initialized |
03-27 | NVM problem |
03-28 | Watchdog software problem |
03-29 | Microprocessor crystal not at correct frequency |
03-30 | No software response from finisher after 20 seconds have elapsed |
06-01 | Lens did not reach 1.1 position |
06-02 | 1/2 rate scanner problem |
06-03 | Scan home problem |
06-04 | Scan home problem |
06-05 | Scan home problem |
06-06 | Scan encoder |
06-07 | Scan encoder |
06-08 | Scan drive boost |
06-09 | Scan encoder |
06-11 | Scan encoder pulse phases |
06-12 | Insufficient scan damping |
07-01 | Duplex tray not home during duplexing |
07-02 | Tray 2 not home when selected |
07-13 | Tray 2 height sensor problem |
07-15 | Tray 2 empty |
07-16 | Tray 1 door open |
07-18 | Tray 1 stack sensor |
07-22 | Tray 1 empty |
07-26 | Tray 1 bypass switch actuated too long |
07-27 | Tray 1 bypass switch deactuated too early |
07-30 | Paper in duplex |
07-31 | Paper in duplex |
07-32 | Duplex tray empty, when paper should be there |
08-10 | Paper did not reach tray 2 input tray sensor |
08-11 | Paper did not reach duplex input sensor |
08-12 | Paper did not reach tray 1 |
08-14 | Paper did not leave tray 2 input sensor quickly enough |
08-18 | Trail edge did not reach tray 2 input sensor quickly enough |
08-19 | Trail edge did not reach tray 1 input sensor quickly enough |
08-20 | Paper in duplex |
08-21 | Paper in tray 2 input |
08-22 | Paper in tray 2 or duplex at wrong time |
08-23 | Paper at tray 1 input at wrong time |
08-24 | Paper in tray 1 at wrong time |
08-28 | Upper and lower nips problem |
09-08 | Low toner condition |
09-12 | Drum signals are out of range |
09-13 | Unstable drum patch readings |
09-15 | Patch is too dark |
09-16 | Patch is too light |
09-17 | Open toner container access cover |
09-18 | Low toner level |
09-21 | Low toner sensor disconnected |
09-22 | Low toner condition, even after machine has been theoretically, adding toner |
10-02 | Low fuser temperature |
10-03 | High fuser temperature |
10-06 | Paper did not reach out put switch |
10-07 | Paper stayed on output switch |
10-10 | Paper did not reach decurler sensor |
10-11 | Paper did not reach decurler sensor |
10-12 | Paper on decurler sensor |
10-13 | Paper did not reach duplex entry sensor in time |
10-14 | Paper did not reach duplex entry sensor in time |
10-15 | Paper on entry sensor at wrong time |
10-17 | Fuser temperature is too high and fuser relay has deactuated |
12-01 | Paper at finisher input sensor |
12-02 | Paper did not reach finisher |
12-03 | Paper reached finisher too soon |
12-05 | Paper at stapler |
12-06 | Paper at stapler |
12-07 | Paper did not reach stapler |
12-08 | Paper did not reach stapler |
12-10 | Complied motor not working properly |
12-15 | Eject motor problem and/or eject encoder |
12-20 | Stacker motor problem |
12-21 | Stacker interlock |
12-22 | Stacker bottom sensor |
12-23 | Stacker bottom sensor |
12-24 | Stacker bottom sensor senses full |
12-25 | Stack height sensor |
12-26 | Stack height sensor |
12-27 | Stack height sensor |
12-30 | Offset home sensor |
12-31 | Offset home sensor |
12-32 | OCT switch |
12-35 | Eject nip carriage |
12-36 | Eject cam interlock |
12-37 | Eject nip carriage open timing |
12-38 | Eject cam interlock |
12-40 | Tamper motor |
12-41 | Tamper home problem |
12-42 | Tamper home sensor |
12-43 | Staple load sensor |
12-44 | Tamper home sensor |
12-45 | Tamper home sensor |
12-50 | Low on staples |
12-51 | Stapler home sensor |
12-52 | Stapler home sensor |
12-53 | Eject cam interlock |
33-37 | Too few documents |
55-01 | RDH interlock switch open during use |
55-04 | Paper on bypass sensor |
55-05 | Paper at vacuum timing sensor |
55-06 | Paper on output sensor |
55-10 | No paper reached S31 |
55-20 | Paper did not leave S31 at correct time |
55-24 | Set counter arm problem |
55-25 | Documents in input tray not detected |
55-27 | Lead edge did not reach S35 at correct time |
55-2955-30 | Trail edge did not reach S35 at correct time |
55-31 | S32, ADF registration sensor did not see paper at correct time |
55-32 | S32 did not see trail edge at correct time |
55-33 | S36 One too many documents |
55-36 | One too many documents |
55-39 | Hole count problem on document feeder belt |
55-40 | Document belt travel problem |
55-41 | Document belt mistracking or skewing |
55-45 | Paper at inverter sensor |
55-47 | Inverter sensor did not see paper lead edge at correct time |
55-49 | More than 50 sheets in input tray |
55-50 | Right side interlock |
55-51 | Left side interlock |
55-55 | Document on glass |
93-93 | NVM has to be initialized after new software installed |
Xerox 5350, 5352
Code | Description |
---|---|
00-009, 030, 031, 032, 033 | A door was opened while paper was being fed |
00-047 | Paper in duplex |
00-1 | Auditron |
00-2 | Diagnostic error |
00-3 | Faults error |
00-4 | Ric error |
00-5 | Job manager system error |
00-6 | LLM interface |
00-7 | Standby error |
00-8 | Communications error |
00-9 | Xerographic error |
01-300 | Front interlock |
01-310 | Right upper interlock |
01-315 | Left upper interlock |
01-320 | Left lower interlock |
01-325 | Fuser interlock |
02-910 | Key counter missing |
02-920 | Wrong combination of accessories |
03-321, 322, 326, 327 | LLM to ISIL communications problems |
03-328 | IOT communications problem with duplex or tray 4 |
03-330 | IOT communications problems with HCF |
03-335, 336 | LLM communications problems with edit |
03-340 | NVM memory |
03-341-347 | Communications problems between IOT and sorter |
03-350-354 | Communications problem with LLM and user interface |
03-363, 364 | Communications problem between LLM & optics |
03-370-03-373 | Communications problem between LLM & DADF |
03-380, 384 | |
03-416-422 | RAM memory problem |
03-424, 426 | NVM memory problem |
03-430, 432 | Billing problem |
03-439 | GRAIB communications problem |
03-440 | RIC communications problem |
03-441 | RIC NVM problem |
03-442 | Modem |
03-443-458 | RIC problems |
03-460 | Serial communications processor problem |
04-300 | Main motor or drive problem |
05-100-108 | DADF registration sensor |
05-110 | DADF exit sensor |
05-115, 120 | DADF jams |
05-305 | DADF document drive |
05-310, 312 | DADF document sensor |
05-316 | DADF registration sensor jam |
05-325 | DADF exit sensor |
05-335, 341, 345 | DADF interlock switches |
06-300-310 | Scan problems |
06-315 | Scan drive |
06-320A, 320B, 320C, 325 | Scan problem |
06-330 | Lens drive |
06-340 | Exposure control problem |
06-342 | LLM CPU problem |
06-344-350 | Exposure cvontrol problem |
06-352 | IOT CPU problem |
07-300, 315, 330, 345 | Tray faults |
07-360-370 | HCF problems |
07-375, 380A, 380B | Duplex problems |
08-100-110 | Feed problems. Lead edge of copy paper is late getting to feed sensor of tray 1 |
08-115-162 | Feed problem. Lead edge of copy paper is late getting to registration sensor |
08-165 | Paper jam at registration sensor |
08-310-370 | Paper at a sensor when power is turned on |
08-330 | DADF nudger sensor |
08-380 | Registration side to side problem with home position |
08-390 | Nip |
09-300 | Copy cartridge finished (drum unit) |
09-310 | Add black toner Add color toner |
09-320 | Add color toner |
09-330 | Wrong copy cartridge (wrong drum unit) |
09-340 | Drum cartridge not installed properly |
09-350 | Waste toner full |
100 | A fault has occurred |
10-100 | Exit jam |
10-105 | Exit jam |
10-110 | Vertical sensor jam |
10-120, 122, 125 | Duplex jam |
10-150, 155 | Too much or not enough paper in duplex tray |
10-300 | Fuser thermistor |
10-302 | Low fuser temperature |
10-304 | Bad fuser temp |
10-308 | High fuser temperature or open thermistor |
10-310 | High fuser temperature |
10-312 | Fuser not up to temperature after energy save |
10-314 | Fuser problem |
10-320 | Fuser web finished |
10-330, 335, 340 | Exit switch, vertical sensor switch actuated when power is turned on |
11-100-116 | Sorter jam |
11-150-176 | Sorter auto stapler jam |
11-310, 314, 316 | Sorter interlock |
11-325A,B,C,D,E,F,G | Sorter index |
11-352, 354, 356 | Sorter auto stapler interlocks |
11-365A,B,C,D,E | Sorter auto stapler bin |
11-370,371,372A,373A,373B,374 | Sorter auto stapler staple failure, staple home problem or tamper home problem |
11-385A,385B,390A,B,C,D,E,396A | Sorter auto stapler staple failure, staple home problem or tamper home problem |
301 | Fuser web must be replaced |
302 | Copy cartridge (drum unit) must be replaced |
501 | Tray 1 must be rebuilt |
502 | Tray 2 must be rebuilt |
503 | Tray 3 must be rebuilt |
504 | Tray 4 must be rebuilt |
505 | HCF must be rebuilt |
506 | Bypass must be rebuilt |
507 | Duplex unit must be rebuilt |
508 | Replace black developer |
509 | Replace red developer |
510 | Replace green developer |
512 | Replace brown developer |
513 | Copy cartridge (drum unit) will need replacing soon |
514 | Fuser web will need replacing soon |
515 | DADF belt should be replaced |
516 | DADF feed rollers should be replaced |
517 | Replace exposure lamp |
518 | Replace suction filter |
519 | Replace ozone filter |
520 | Replace optics filter |
521 | Replace particle filter |
522 | Replace upper fuser roller |
523 | Replace fuser pawls |
524 | Replace pressure roller |
525 | Replace pressure roller pawls |
900-905 | Key operator calls |
Xerox 5355
Код ошибки | Описание |
---|---|
01-01 | Frequency monitoring and zero cross problem |
01-02 | Interlock |
01-03 | AC power problem |
01-04 | Finisher interlock |
01-05 | 24v problem |
03-01 | Optics to main board communication problem |
03-02 | Software reset problem |
03-03 | Could be punched holes in the lead edge of the original |
03-04 | Software problem |
03-06 | Low battery |
03-07 | NVM not initialized or is missing or defective |
03-17 | Communication problem between main board and finisher board |
03-18 | Initializes one NVM counter to agree to others |
03-19 | All three NVM counter to agree with others |
03-20 | Main board/interface board problems |
03-21 | Problem with RIC NVM |
03-22 | RIC modem problem |
03-23 | RIC real time clock failure. |
03-25 | RIC NVM problem or not initialized |
03-27 | NVM problem |
03-28 | Watchdog software problem |
03-29 | Microprocessor crystal not at correct frequency |
03-30 | No software response from finisher after 20 seconds have elapsed |
06-01 | Lens did not reach 1.1 position |
06-02 | 1/2 rate scanner problem |
06-03 | Scan home problem |
06-04 | Scan home problem |
06-05 | Scan home problem |
06-06 | Scan encoder |
06-07 | Scan encoder |
06-08 | Scan drive boost |
06-09 | Scan encoder |
06-11 | Scan encoder pulse phases |
06-12 | Insufficient scan damping |
07-01 | Duplex tray not home during duplexing |
07-02 | Tray 2 not home when selected |
07-13 | Tray 2 height sensor problem |
07-15 | Tray 2 empty |
07-16 | Tray 1 door open |
07-18 | Tray 1 stack sensor |
07-22 | Tray 1 empty |
07-26 | Tray 1 bypass switch actuated too long |
07-27 | Tray 1 bypass switch deactuated too early |
07-30 | Paper in duplex |
07-31 | Paper in duplex |
07-32 | Duplex tray empty, when paper should be there |
08-10 | Paper did not reach tray 2 input tray sensor |
08-11 | Paper did not reach duplex input sensor |
08-12 | Paper did not reach tray 1 |
08-14 | Paper did not leave tray 2 input sensor quickly enough |
08-18 | Trail edge did not reach tray 2 input sensor quickly enough |
08-19 | Trail edge did not reach tray 1 input sensor quickly enough |
08-20 | Paper in duplex |
08-21 | Paper in tray 2 input |
08-22 | Paper in tray 2 or duplex at wrong time |
08-23 | Paper at tray 1 input at wrong time |
08-24 | Paper in tray 1 at wrong time |
08-28 | Upper and lower nips problem |
09-08 | Low toner condition |
09-12 | Drum signals are out of range |
09-13 | Unstable drum patch readings |
09-15 | Patch is too dark |
09-16 | Patch is too light |
09-17 | Open toner container access cover |
09-18 | Low toner level |
09-21 | Low toner sensor disconnected |
09-22 | Low toner condition, even after machine has been theoretically, adding toner |
10-02 | Low fuser temperature |
10-03 | High fuser temperature |
10-06 | Paper did not reach out put switch |
10-07 | Paper stayed on output switch |
10-10 | Paper did not reach decurler sensor |
10-11 | Paper did not reach decurler sensor |
10-12 | Paper on decurler sensor |
10-13 | Paper did not reach duplex entry sensor in time |
10-14 | Paper did not reach duplex entry sensor in time |
10-15 | Paper on entry sensor at wrong time |
10-17 | Fuser temperature is too high and fuser relay has deactuated |
12-01 | Paper at finisher input sensor |
12-02 | Paper did not reach finisher |
12-03 | Paper reached finisher too soon |
12-05 | Paper at stapler |
12-06 | Paper at stapler |
12-07 | Paper did not reach stapler |
12-08 | Paper did not reach stapler |
12-10 | Complied motor not working properly |
12-15 | Eject motor problem and/or eject encoder |
12-20 | Stacker motor problem |
12-21 | Stacker interlock |
12-22 | Stacker bottom sensor |
12-23 | Stacker bottom sensor |
12-24 | Stacker bottom sensor senses full |
12-25 | Stack height sensor |
12-26 | Stack height sensor |
12-27 | Stack height sensor |
12-30 | Offset home sensor |
12-31 | Offset home sensor |
12-32 | OCT switch |
12-35 | Eject nip carriage |
12-36 | Eject cam interlock |
12-37 | Eject nip carriage open timing |
12-38 | Eject cam interlock |
12-40 | Tamper motor |
12-41 | Tamper home problem |
12-42 | Tamper home sensor |
12-43 | Staple load sensor |
12-44 | Tamper home sensor |
12-45 | Tamper home sensor |
12-50 | Low on staples |
12-51 | Stapler home sensor |
12-52 | Stapler home sensor |
12-53 | Eject cam interlock |
33-37 | Too few documents |
55-01 | rdh interlock switch open during use |
55-04 | Paper on bypass sensor |
55-05 | Paper at vacuum timing sensor |
55-06 | Paper on output sensor |
55-10 | No paper reached S31 |
55-20 | Paper did not leave S31 at correct time |
55-24 | Set counter arm problem |
55-25 | Documents in input tray not detected |
55-27 | Lead edge did not reach S35 at correct time |
55-2955-30 | Trail edge did not reach S35 at correct time |
55-31 | S32, ADF registration sensor did not see paper at correct time |
55-32 | S32 did not see trail edge at correct time |
55-33 | S36 One too many documents |
55-36 | One too many documents |
55-39 | Hole count problem on document feeder belt |
55-40 | Document belt travel problem |
55-41 | Document belt mistracking or skewing |
55-45 | Paper at inverter sensor |
55-47 | Inverter sensor did not see paper lead edge at correct time |
55-49 | More than 50 sheets in input tray |
55-50 | Right side interlock |
55-51 | Left side interlock |
55-55 | Document on glass |
93-93 | NVM has to be initialized after new software installed |
Xerox XC520, 540, 560, 580
Код ошибки | Описание |
---|---|
H2 | Fuser thermistor |
H3 | Fuser temperature too high. Must be reset in diagnostics |
H4 | Fuser temperature too low. Must be reset in diagnostics |
L3 | Scan problem |
L4 | Min motor drive problem |
L8 | Exposure lamp not lightning or not enough light reaching auto exposure sensor |
P | Paper did not feed |
Xerox 5622
Code | Description |
---|---|
A1-1 to A1-32 | All indicate a paper path problem, etc. in the ADF |
A2 | ADF exit problems |
A3 | Irregular size documents |
A5 | ADF interlock |
A6 | ADF single sheet document reset |
A7 | Platen interlock |
A8 | ADF exit interlock |
C1 | Tray 1 jam |
C2 | Tray 2 jam |
C3 | Tray 3 jam |
C6-1, C6-2 | Jams related to duplex |
C6-3 | Registration sensor, re tray 1 |
C7-1, C7-2 | HCF feed problems |
C7-3 | Tray 1 feed problem |
C8 | Paper stays in tray or duplex or HCF |
C9 | Bypass feed problem |
E1-10 to E1-25 | Internal jam |
E1-6 | Paper on registration sensor |
E2 | Reset signal happened. Might read E-2 something else |
E3-30 to E4-14 | Exit jam |
E3-6 | Exit jam |
E4-10 to E4-14 | Inverter sensor not actuated |
E4-15 | Inverter sensor |
E4-40 to E4-45 | Duplex entry sensor |
E4-6 | Inverter sensor |
E5 | Front door interlock |
E6-1 | Tray 1 interlock |
E6-2 | 2 tray or duplex interlock |
E6-3 | HCF interlock |
E7-2, E7-3 | Duplex interlock |
E8-6 to E8-15 | Duplex entry sensor |
F1-1 | Sorter entry sensor |
F1-6 | Sorter exit sensor |
F3 | Paper size not available for sort/stack |
F5 | Sorter interlock |
J1 | Add toner |
J3 | Replace copy cartridge |
J7 | Replace copy cartridge |
J8-1 | Wrong copy cartridge installed |
J8-2 | Copy cartridge EEPROM |
L6 | Auditron or other counter problem |
L8 | Platen glass temperature is too high |
L9 | Communication problem between interimage erase/edge lamps and main board |
U1-1 | Main motor drive problem |
U2-1 to U2-4 | Scan home sensor |
U3-1 | Lens sensor |
U4-1 | Open fuser thermistor |
U4-2 | Fuser did not warm up properly |
U4-3 | Fuser temperature too high |
U4-4 | Fuser problem. Staying on too long |
U4-6 | High fuser temperature |
U5-1 | Sorter bin home switch not activated |
U5-2 | Sorter bin home switch stayed actuated |
U5-3, U5-4 | Sorter bin home switch |
U6-1 | ROM problem |
U6-2 | RAM problem |
U6-3 | Low battery |
U6-4 | Incorrect value in NVM. Reinitialize main board with code 20-96 |
U8-1 to U8-6 | Problem with exposure lamp, lamp sensor, lamp board |
Перейти к содержанию
На чтение 2 мин Просмотров 103 Опубликовано 30 сентября, 2016
Произошло замятие бумаги, загруженной в кассету (нижнюю).
Решение
Удалите замятую бумагу, выполнив следующие действия —
ПРИМЕЧАНИЕ — Не допускается отключение питания во время отправки или приема факса, либо когда полученный факс или не отправленные факсы хранятся в памяти устройства. Перед отсоединением кабеля питания убедитесь, что устройство завершило отправку или получение факсов. Если отключить кабель питания, все не отправленные документы, сохраненные в памяти устройства, будут утеряны.
Реклама
- Для отмены заданий печати нажмите кнопку [Stop/Стоп] и выключите устройство.
- Снимите заднюю крышку.
- Аккуратно извлеките замятую бумагу.
ПРИМЕЧАНИЕ — Не прикасайтесь к внутренним частям устройства. Если не удается вытянуть бумагу, откройте лоток приема бумаги. - Установите заднюю крышку.Если не удается извлечь бумагу в шаге 3, выполните действия, описанные ниже:
- Снимите нижнюю и верхнюю кассеты.
- Аккуратно извлеките замятую бумагу.
- Если бумага не загружается в кассету должным образом, извлеките бумагу и загрузите ее снова, выровняв края листов.
ПРИМЕЧАНИЕ — При повторной загрузке бумаги убедитесь, что используется подходящая для печати бумага и загрузка выполняется правильно. - Установите кассеты в устройство, затем нажмите кнопку [OK].
Вконтакте
Google+
Мы будем вынуждены удалить ваши комментарии при наличии в них нецензурной брани, оскорблений и спама.
Уважаемые посетители! В последнее время в комментариях к статьям (в Виджете коментариев ВК) появились спамные сообщения, которые грубо отзываются о сайтах на которых размещаются эти комментарии, и есть предложение перейти по ссылке на другой сайт. Ссылка как правило ведет на сайт который предлагает скачать вредоносное ПО под видом полезного.
Так как мы не всегда вовремя успеваем реагировать на подобны комментарии, вы ДОЛЖНЫ сами быть бдительны и ни в коем случае не переходить по данным ссылкам. Ни сайт неОшибка.Ру, ни его создатели, ни его администрация не имеет ничего общего с этими сообщениями, и не несет никакой ответственности за ваши действия. Помните об этом.
Вот пример такого комментария:
Содержание
- Исправляем ошибку печати на принтере HP
- Способ 1: Проверка принтера
- Способ 2: Разблокирование процедуры печати
- Способ 3: Отключение брандмауэра Windows
- Способ 4: Переключение учетной записи пользователя
- Способ 5: Восстановление Windows
- Способ 6: Переустановка драйвера
- Вопросы и ответы
Обладатели печатной продукции от компании HP иногда сталкиваются с тем, что на экране появляется уведомление «Ошибка печати». Причин возникновения этой неполадки может быть несколько и каждая из них решается по-разному. Сегодня мы подготовили для вас разбор основных способов исправления рассматриваемой проблемы.
Каждый приведенный ниже метод имеет разную эффективность и будет наиболее подходящим в определенной ситуации. Мы по порядку рассмотрим все варианты, начиная от самого простого и действенного, а вы, следуя инструкциям, решите поставленную задачу. Однако сначала мы рекомендуем обратить внимание на эти советы:
- Перезапустите компьютер и переподключите устройство печати. Желательно, чтобы перед следующим подключением принтер находится в выключенном состоянии не менее одной минуты.
- Проверьте картридж. Иногда ошибка появляется в тех случаях, когда в чернильнице закончилась краска. О том, как заменить картридж вы можете прочитать в статье по ссылке ниже.
- Осмотрите провода на наличие физических повреждений. Кабель выполняет передачу данных между компьютером и принтером, поэтому важно, чтобы он не только был подключен, но и находился полностью в исправном состоянии.
- Кроме этого советуем проверить, не закончилась ли бумага или не зажевало ли ее внутри механизма оборудования. Вытащить лист А4 вам поможет инструкция, которая прилагается в комплекте с продукцией.
Подробнее: Замена картриджа в принтере
Если приведенные советы ничем не помогли, переходите к осуществлению следующих методов решения «Ошибка печати» при использовании периферии компании HP.
Способ 1: Проверка принтера
В первую очередь советуем проверить отображение и конфигурацию оборудования в меню «Устройства и принтеры». От вас потребуется произвести всего несколько действий:
- Через меню «Панель управления» и переместитесь в «Устройства и принтеры».
- Убедитесь, что устройство не подсвечивается серым цветом, после чего нажмите на нем ПКМ и кликните на пункт «Использовать по умолчанию».
- Кроме этого рекомендуется проверить параметры передачи данных. Зайдите в меню «Свойства принтера».
- Здесь вас интересует вкладка «Порты».
- Отметьте галочкой пункт «Разрешить двусторонний обмен данными» и не забудьте применить изменения.
По окончании процесса рекомендуется перезагрузить ПК и переподключить оборудование, чтобы все изменения точно стали активными.
Способ 2: Разблокирование процедуры печати
Иногда происходят скачки напряжения или различные системные сбои, вследствие чего периферия и ПК перестают нормально выполнять определенные функции. По таким причинам и может возникать ошибка печати. В таком случае вам следует проделать следующие манипуляции:
- Снова перейдите в «Устройства и принтеры», где правым кликом мыши на активном оборудовании выберите пункт «Просмотр очереди печати».
- Нажмите ПКМ на документ и укажите «Отменить». Повторите это со всеми присутствующими файлами. Если процесс по каким-либо причинам не отменяется, советуем ознакомиться с материалом по ссылке ниже, чтобы осуществить эту процедуру одним из других доступных методов.
- Вернитесь в «Панель управления».
- В ней откройте категорию «Администрирование».
- Здесь вас интересует строка «Службы».
- В списке отыщите «Диспетчер печати» и дважды нажмите на нем ЛКМ.
- В «Свойства» обратите внимание на вкладку «Общие», где убедитесь, что тип запуска стоит «Автоматический», после чего следует остановить службу и применить настройки.
- Закройте окно, запустите «Мой компьютер», переместитесь по следующему адресу:
C:WindowsSystem32SpoolPRINTERS
- Удалите все присутствующие файлы в папке.
Подробнее: Как очистить очередь печати на принтере HP
Осталось только выключить продукт компании HP, отключить его от питания, дать так постоять примерно минуту. После этого перезагрузите ПК, соедините оборудование и повторите процесс печати.
Способ 3: Отключение брандмауэра Windows
Иногда защитник Windows блокирует отправленные данных с компьютера на устройство. Связано это может быть с некорректной работой брандмауэра или различными системными сбоями. Мы советуем на время отключить защитник Виндовс и повторить попытку печати. Детальнее о деактивации этого инструмента читайте в другом нашем материале по следующим ссылкам:
Подробнее: Отключение брандмауэра в Windows XP, Windows 7, Windows 8
Способ 4: Переключение учетной записи пользователя
Рассматриваемая проблема порой возникает тогда, когда попытка отправки в печать производится не с той учетной записи пользователя Windows, с которой происходило добавление периферии. Дело в том, что каждый профиль имеет свои привилегии и ограничения, что приводит к появлению подобного рода неполадок. В таком случае нужно попробовать сменить запись юзера, если у вас их конечно добавлено больше, чем одна. Развернуто о том, как это сделать в разных версиях Виндовс читайте в статьях ниже.
Подробнее: Как сменить учетную запись пользователя в Windows 7, Windows 8, Windows 10
Способ 5: Восстановление Windows
Часто случается, что ошибки печати связаны с определенными изменениями в операционной системе. Самостоятельно обнаружить их достаточно сложно, однако состояние ОС можно вернуть, откатив все изменения. Осуществляется данная процедура с помощью встроенного компонента Виндовс, а детальное руководство по этой теме вы найдете в другом материале от нашего автора.
Подробнее: Варианты восстановления ОС Windows
Способ 6: Переустановка драйвера
Мы поставили этот способ последним, поскольку он требует от пользователя выполнения большого количества различных манипуляций, а также является достаточно сложным для новичков. Если никакие приведенные выше инструкции вам не помогли, значит остается только переустановить драйвер устройства. Для начала следует избавиться от старого. О том, как это сделать, читайте далее:
Читайте также: Удаление старого драйвера принтера
По завершении процедуры удаления задействуйте один из методов инсталляции программного обеспечения для периферии. Всего существует пять доступных способов. Развернуто с каждыми из них знакомьтесь в другой нашей статье.
Подробнее: Установка драйверов для принтера
Как видите, методов исправления ошибки печати принтера HP существует достаточно большое количество, и каждый из них будет полезен в разных ситуациях. Надеемся, приведенные выше инструкции помогли вам без труда решить возникшую проблему, а продукт компании снова функционирует корректно.